Abstract
Purpose
To evaluate the performance of artificial membranes in in vitro lipolysis-permeation assays useful for absorption studies of drugs loaded in lipid-based formulations (LBFs).
Methods
Polycarbonate as well as PVDF filters were treated with hexadecane, or lecithin in n-dodecane solution (LiDo) to form artificial membranes. They were thereafter used as absorption membranes separating two compartments mimicking the luminal and serosal side of the intestine in vitro. Membranes were subjected to dispersions of an LBF that had been digested by porcine pancreatin and spiked with the membrane integrity marker Lucifer Yellow (LY). Three fenofibrate-loaded LBFs were used to explore the in vivo relevance of the assay.
Results
Of the explored artificial membranes, only LiDo applied to PVDF was compatible with lipolysis by porcine pancreatin. Formulation ranking based on mass transfer in the LiDo model exposed was the same as drug release in single-compartment lipolysis. Ranking based on observed apparent permeability coefficients of fenofibrate with different LBFs were the same as those obtained in a cell-based model.
Conclusions
The LiDo membrane was able to withstand lipolysis for a sufficient assay period. However, the assay with porcine pancreatin as digestive agent did not predict the in vivo ranking of the assayed formulations better than existing methods. Comparison with a Caco-2 based assay method nonetheless indicates that the in vitro in vivo relationship of this cell-free model could be improved with alternative digestive agents.
Electronic supplementary material
The online version of this article (10.1007/s11095-020-02833-9) contains supplementary material, which is available to authorized users.
Key Words: artificial membrane, digestion, lipid-based formulation, permeation, self-emulsifying oral drug-delivery systems
Introduction
Artificial membranes can be a valuable tool for evaluating properties of drug compounds pertaining to barrier interactions (1). When properly used, they can give information about functional characteristics with increased cost-effectiveness and fewer ethical concerns than animal- or cell-based experiments. However, it is important to identify the limits of such membranes so that they can be used to produce valid experimental data. In the digestion process (lipolysis) of lipid-based formulations (LBFs), membranes will be subjected to a matrix consisting of surfactants and lipids, along with lipid digesting enzymes, which may affect the membrane structure and its integrity over time. In this study, the suitability of artificial membranes to enhance the in vitro lipolysis assay with simultaneous absorption (lipolysis-permeation assay) was investigated.
Between 2015 and 2019, the number of highly lipophilic (logP >5) New Molecular Entities (NMEs) accounted for approximately 15% of all NMEs intended for oral administration (Table S1, Supplementary Material). Moderately to highly lipophilic NMEs (logP >3) from 2015 to 2019 accounted for 49% (2). Highly lipophilic drug compounds often suffer from inter- and intraindividually variable bioavailability. Apart from metabolism, this variability can be caused largely by solubility issues and influenced by factors like gastrointestinal physiology, prandial state during the time of administration, and composition of the latest meal. Thus, it is important to consider the formulation of these APIs in such a way that their negative characteristics can be minimized.
LBFs such as self-emulsifying drug delivery systems (SEDDS) is a tool in the formulator’s toolbox for improving bioavailability for poorly water-soluble drugs, an alternative to other options such as salt formation, solid dispersion, amorphization, or complexation. By 2016, there were at least 35 LBF drug products approved by the FDA, but the rate of new LBFs coming out on the market has slowed down in recent years (Fig. S1, Supplementary Material) (3,4). One conceivable reason for this decline could be difficulties in development, since the technique by itself has many advantages.
LBF can help avoid food effects (5), reducing susceptibility to the patient’s prandial state and gastrointestinal physiology. By pre-dissolving the API in lipid excipients together with surfactants and co-solvents, the apparent solubility within the GI tract is less affected by the timing of administration. LBF has also been shown to increase the bioavailability of BCS (biopharmaceutics classification system) class II and IV drugs (5–8), possibly by circumventing the dissolution step in the intestine. However, several studies have shown that an API does not necessarily have to be fully dissolved within an LBF, but that co-administration with crystalline material can be sufficient to increase the amount of solubilized drug and bioavailability (9,10), in a phenomenon sometimes described as the “chasing principle” (11). This effect means that dissolution prior to administration might not be necessary for effective drug delivery via LBF. There are several hypotheses as to the mechanism(s) underlying this increased bioavailability, yet little conclusive proof. At the same time, there is a lack of useful in vitro methods for predicting the in vivo efficacy. Thus, it is difficult to optimize LBFs rationally and without conducting large numbers of animal experiments, which means that developing a drug product formulated with lipids might be less attractive than other advanced formulation techniques.
The current gold standard for evaluation of LBFs is the in vitro lipolysis assay in which formulations are dispersed in simulated intestinal fluid and subjected to digestion by pancreatic enzymes. This method could possibly be considered a more biorelevant drug release test than standard pharmacopeial dissolution methods (12). In the in vitro lipolysis assay, the amount of API solubilized – or available for absorption – is expected to correlate to the in vivo performance, because the APIs are typically highly permeable. However, when comparing LBFs of different compositions, the in vitro in vivo relationship (IVIVR) of drug release with bioavailability fails to reach even rank-order in many cases (9,13,14); the reader is advised to read the review by Feeney et al. (15) for further details. This observation suggests that the mechanisms of action for LBFs are not necessarily as simple as increasing apparent solubility within the intestinal media or supersaturation effects driving permeation. It should however be noted that supersaturation can be difficult to accurately determine (16).
Successful attempts at predicting the in vivo exposure from in vitro data have been made by simulations based on physiologically based pharmacokinetic (PBPK) models (17,18). When the absorption of drug and lipolysis products is taken into account, it is possible to predict the impact of the formulation on the fate of the API more accurately. These models require parameterization based on in vivo studies to simulate new in vivo data, as well as in vitro data as input. When this is available, PBPK simulations can provide very valuable mechanistic insights into the biopharmaceutical properties of the formulated drug. For initial screening of formulations however, PBPK simulations can present a significant challenge because of the input data and effort required to parameterize the models. A sufficiently biorelevant in vitro method – that incorporates simultaneous lipolysis and absorption – could offer the possibility of less time-consuming direct comparisons of formulations, without requiring preclinical pilot studies. The generated data can then be used to inform PBPK models and simulations at a later stage.
Recently, an in vitro method was published in which effectiveness of LBFs was gauged by adding simultaneous absorption via a Caco-2 monolayer to the in vitro lipolysis assay (19). This method has shown good IVIVR by assessing mass transfer across the monolayer (9,19), a promising step towards a more efficient development process for LBFs. However, cultured cells are not compatible with all formulations or digestive agents (20,21). Culturing and handling of cells also requires significant effort and expertise. To try to minimize these problems, we investigated the effectiveness of replacing the cell monolayer with an artificial (cell-free) lipid membrane. The method investigated in this study – implementing artificial membranes as the absorption compartment barrier – could potentially complement the cell-based method and allow formulations of APIs to be assayed more effectively, in particular those absorbed mainly by passive transcellular diffusion.
Materials and Methods
Materials
Acetonitrile (≥ 99.9%), methanol (99.9%), fenofibrate, warfarin, porcine pancreatin (8 x USP specifications), bovine serum albumin, dimethyl sulfoxide (DMSO, ≥ 99.9%) D-α-Tocopherol polyethylene glycol succinate (TPGS), hexadecane (anhydrous, 95%), Tris-maleate, 4-bromophenol boronic acid, olive oil, Kolliphor EL (macrogolglycerol ricinoleate), Kolliphor RH40 (macrogolglycerol hydroxystearate), Tween 85, and Carbitol (diethylene glycol monoethyl ether) were purchased from Merck (Darmstadt, Germany). Felodipine was kindly donated by Lundbeck Pharma (Valby, Denmark). Captex 355 and Capmul MCM EP (Abitec, Janesville, WI, USA) were kindly donated by Barentz (Odense, Denmark). Miglyol 812 N was obtained from IOI Oleo (Wittenberge, Germany). FaSSIF/FeSSIF/FaSSGF powder were bought from Biorelevant.com (Croydon, UK). Lucifer Yellow CH dilithium salt was obtained from Biotium (Fremont, CA, USA). Lecithin 20% soy PC extract was obtained from Avanti Polar Lipids (Alabaster, AL, USA). GIT-0 lipid solution and Acceptor Sink Buffer were purchased from Pion (Billerica, MA, USA). N-dodecane (≥ 99%) was obtained from Alfa Aesar (Lancashire, UK). Ethanol (99.5%, denatured with 0.4% isopropyl alcohol) was obtained from Solveco (Rosersberg, Sweden). All water used was of grade I from a Milli-Q lab water purification system (Merck).
Artificial Membrane Preparation
Hexadecane membranes (HDMs) were prepared as previously described by Matsson et al. (22). In short, a 5% (v/v) solution of hexadecane in hexane was added to Transwell inserts (Corning, polycarbonate filter, 24 mm diameter, 10 μm thickness, 0.4 μm pore size with nominal pore density 1 × 108 pores/cm2). The hexane was allowed to evaporate for at least one hour from the filter-immobilized hexadecane membrane (HDM). HDMs were hydrated with 10 mM phosphate buffer solution for 30 min before use, at 37°C in an orbital shaker at 400 rpm.
Based on data extracted from DS-PAMPA method (23) and the GIT-0 formulation (24), a generic membrane-forming solution – referred herein as lecithin-in-dodecane (LiDo) – was prepared by dissolving Avanti’s 20% Soy PC extract in a solution of 1.5% (v/v) absolute ethanol in n-dodecane, to a final concentration of 20% (w/v) lecithin. After overnight dissolution, the solution was centrifuged at 3220 g at 20°C for 20 min to remove undissolved material. The LiDo solution was then aliquoted and stored under argon at −18°C until use. This preparation corresponds functionally to the commercially available GIT-0 lipid solution (Fig. S2, Supplementary Material). Quantitative analysis showed less than 10% difference in relative abundance per phospholipid species between lab-prepared and commercially procured lipid solution. LiDo and GIT-0 solutions were thawed at room temperature overnight, and membranes were prepared 10 min prior to the start of experiments by coating either polycarbonate or PVDF filter supports (Millipore Immobilon-P, 0.45 μm pore size, thickness 100–145 μm) with 16.2 μl of lipid solution per cm2 of filter.
Conventional In Vitro Lipolysis Method
Lipolysis was performed as previously described by Alskär et al., using the Metrohm Titrando equipment with automated pH-titration and overhead stirring of the medium with an impeller (25). In short, 1.66 g of formulation was weighed into a jacketed glass vessel kept at 37°C, followed by addition of 53.3 ml digestion medium. The digestion medium was prepared by dissolving FaSSIF/FeSSIF/FaSSGF powder (2.24 g/l, obtaining 3 mM taurocholate and 0.75 mM lecithin) in lipolysis buffer (pH 6.5, containing 2 mM Tris-maleate, 150 mM NaCl, and 1.4 mM CaCl2). The mixture was dispersed at 450 rpm for 10 min and if necessary, manually adjusted to pH 6.5 using 0.1 M NaOH solution. After 10 min of dispersion, 5.92 ml porcine pancreatin extract was added to initiate digestion. The extract was prepared by dispersing 1.6 g porcine pancreatin powder in 8 ml cold lipolysis buffer, followed by centrifugation at 2690 g for 15 min (5°C) and extracting the supernatant (6600 TBU/ml, corresponding to ~4000 USP units/ml (26)). A 0.6 M NaOH solution was used as titrant to keep pH stable at 6.5 by autotitration during the digestions. To estimate the total extent of digestion, the amount of titrant required to raise the pH to 9.0 and ionize all of the released free fatty acids was measured. For this measurement, a lipolysis of blank digestion medium was used as reference to exclude digestion medium effects from the required titrant volume.
Integrity Assay with Static Digest Matrix
Six samples of 4 ml were taken during dispersion and digestion phases of single-compartment in vitro lipolysis (Fig. 1a) of a formulation over a period of 40 min. The formulation was of type IIIB-MC (medium chain length triglyceride component, 8–10 carbons) according to the Lipid Formulation Classification System (LFCS) (27), see Table I for composition. Lipolysis was immediately inhibited in the samples through addition of 0.5 M solution of 4-bromophenol boronic acid in methanol (5 μl/ml of sample). To visualize membrane integrity, Lucifer Yellow (LY) in DMSO solution was added to each sample to a final LY concentration of 10 μM and 0.1% DMSO. LY is highly hydrophilic; its permeation through intact lipid membranes should therefore be negligible. The sample tubes were then vortexed, and shaken at 450 rpm at 37°C until further use.
Table I.
LBF typea | Digestible lipid excipients | % (w/w) | C:Db | Surfactant excipients | % (w/w) | HLBc | Co-solvent excipients | % (w/w) |
---|---|---|---|---|---|---|---|---|
IIIB-MC | Captex 355 | 12.5 | 8:0, 10:0 | Kolliphor EL | 50 | 12–14 | Carbitol | 25 |
Capmul MCM EP | 12.5 | 8:0, 10:0 | ||||||
IIIA-MC | Miglyol 812 N | 40 | 8:0, 10:0 | Tween 85 | 40 | 11 | – | – |
Kolliphor RH40 | 20 | 14–16 | ||||||
IIIA-LC | Olive oil | 40 | 18:1–2, 16:0 | Tween 85 | 40 | 11 | – | – |
Kolliphor RH40 | 20 | 14–16 | ||||||
IV | – | – | – | Tween 85 | 67 | 11 | – | – |
Kolliphor RH40 | 33 | 14–16 |
aLipid-based formulation (LBF) type based on the Lipid Formulation Classification System (27) and lipid chain length, as either medium chain (MC) or long chain (LC). bNumber of carbons (C) and unsaturations (D) in the acyl chains of the respective digestible lipids comprising the formulation. cHydrophilic-lipophilic balance values (HLB) of non-ionic surfactants according to manufacturer information
Digestion samples were dispensed (1.2 ml) into the donor compartments of Transwell inserts treated to form artificial membranes. Negative controls comprised only blank digestion medium or lipolysis buffer (both containing LY, 10 μM) in the donor compartment. Positive controls were untreated inserts composed of naked polycarbonate filters, or GIT-0 solution added to pre-wet filters (disrupts membrane formation). The receiver compartments contained 2 ml of either plain phosphate buffer (PB, 10 mM), Acceptor Sink Buffer (20 mM HEPES, 1% w/v SDS), or PB supplemented with 4% w/w bovine serum albumin (BSA). All receiver buffers were adjusted to pH 7.40.
From examination of mass transfer profiles, membrane damage was evaluated by Area Under the Curve (AUC) values of LY mass transfer over time. The criteria were that an LY AUC > 10 nmol min cm−2 was considered to indicate major membrane disruption, while an LY AUC < 1 nmol min cm−2 was considered to indicate an intact membrane.
Integrity Assay under Dynamic Digestion Conditions
HDM, GIT-0 and LiDo membranes were subjected to in situ lipolysis of the IIIB-MC LBF in a 6-well culture plate format. Transwell inserts (diameter of 24 mm) were used for polycarbonate filters, and inserts were made in-house to hold the PVDF filters (diameter of 25 mm). For these lipolysis experiments, a modified digestion medium with greater buffering capacity was used. The digestion medium contained 200 mM Tris-maleate in these experiments to maintain pH within 0.3 units of the initial value of the lipolysis buffer (pH 6.5) over one hour of digestion (Table S2, Supplementary Material), since no autotitration could be used in the setup. LBF was weighed into a glass tube, and 10 ml of this modified digestion medium spiked with 10.3 μl of LY in DMSO solution (10 mM) was added and vortexed. To the insert donor compartments, 1.35 ml of this mixture was then immediately added, and the plates were placed in an orbital shaker for 10 min (400 rpm, 37°C). This step was intended to mimic the dispersion phase of an in vitro lipolysis assay, after which digestion was initiated through addition of 148 μl of porcine pancreatin extract per insert (final activity ~750 TBU/ml).
GIT-0 and LiDo membranes were also evaluated in a large-scale (75 mm diameter) in-house developed lipolysis-permeation device named “ENA” (19) in order to explore whether these two lipid mixtures with theoretically similar compositions and production methods also yielded similar results. These experiments were performed as for a conventional single-compartment in vitro lipolysis assay, but with LBF and LY (10 μM) dispensed into the digestion medium (2 mM Tris-maleate) with stirring. The receiver compartment contained 10 mM phosphate buffered saline (140 mM NaCl, 2.7 mM KCL, pH 7.4) supplemented with 4% (w/w) BSA for all integrity assays under dynamic conditions.
In Vitro Lipolysis and Permeation Assay of Loaded LBFs
Three formulations representing LFCS types IIIA-MC, IIIA-LC (long chain fatty acid component), and type IV (Table I) were assayed for their performance using artificial membranes in the ENA device. No more than one week before the assay, excipients were heated to 37°C before being weighed into a glass vial. The vial was capped with argon, vortexed, and then shaken overnight (450 rpm, 37°C). The formulations were then loaded with fenofibrate (80 mg/g) in the same manner, and shaken until complete dissolution. This loading corresponded to 55.6, 82.8, and 76.6% of equilibrium solubility at 37°C for LBF types IIIA-MC, IIIA-LC, and IV, respectively (14).
The loaded formulations were weighed separately and then dispensed into ENA donor compartments (Fig. 1b) that had been prefilled with digestion medium spiked with LY to 10 μM (0.1% DMSO). Samples were taken from both compartments during dispersion (0–10 min) and digestion (10–100 min). Samples from the donor compartment were immediately filtered through a hydrophilic nylon syringe filter (Whatman PuraDisc 13, pore size 0.1 μm) to separate precipitates and oil droplets from fenofibrate in free solution and in colloidal aggregates, using the same procedures as those described in Juenemann et al. and Stillhart et al. (28,29). The syringe filters were then flushed through with room temperature acetonitrile to recover precipitated fenofibrate. It was not possible to filter some early samples (5–20 min) of type IIIA-LC formulation digestion due to high backpressure. Phases were instead separated through centrifugation (37°C, 21,000 g for 15 min) for these samples. Receiver compartment samples were then quantified using UPLC-MS, and donor samples using HPLC-UV.
Sample Analysis
LY presence was detected using fluorescence (Spark or Safire2 plate readers, Tecan, Austria) at 428 and 536 nm wavelength for excitation and emission, respectively. Samples were diluted 1:2 in ice-cold acetonitrile and centrifuged (4°C, 2465 g for 20 min) to precipitate protein content.
Fenofibrate was analyzed using a UV-DAD coupled HPLC (1290 Infinity, Agilent Technologies) with a Zorbax Eclipse XDB-C18 column (4.6 × 100 mm, Agilent Technologies) kept at 40°C (injection volume 20 μl). The mobile phase consisted of sodium acetate buffer (25 mM, pH 5.0) in acetonitrile solution (2:8 v/v) with isocratic flow (1 ml/min). UV absorbance was monitored at a wavelength of 287 nm. The retention time was 3.32 min. Sample preparation consisted of 100x dilution in mobile phase and a centrifugation step (21,000 g, 15 min, 25°C) to purify the matrix.
UPLC-MS analysis was performed using a Xevo TQ MS coupled Acquity UPLC system (Waters, Milford, MA) with a BEH C18 column (2.1 × 50 mm, 1.7 μm, Waters). The mobile phase consisted of 5% acetonitrile and 0.1% formic acid in water (solvent A), and 0.1% formic acid in acetonitrile (solvent B). Gradient elution at a constant flow rate of 0.8 ml/min was used. Mobile phase A was decreased linearly (95 to 0%) from 0.2 to 0.65 min, followed by a constant flow for 0.15 min, and then a linear increase back to 95% A at 0.8 min until the end of the run (1 min, injection volume 10 μL). The column oven and auto-sampler tray temperature were set at 60°C and 10°C respectively.
The mass spectrometer was operated in positive electrospray mode for fenofibrate and fenofibric acid, and in negative mode for warfarin (internal standard of the analytics). The retention times of these compounds were 0.89, 0.79, and 0.76 min, respectively. Precursor-product ion pairs followed were: (i) m/z 361 → 233 (cone voltage 20 and collision energy 16 V) for fenofibrate, (ii) m/z 319 → 139 (cone voltage 20 and collision energy 32 V) for fenofibric acid, and (iii) m/z 309 → 163 (cone voltage 22 and collision energy 14 V) for warfarin. Data acquisition and peak integration were performed with MassLynx software (Waters). Sample preparation consisted of dilution in receiver buffer (1x, 10x, and 100x), followed by dilution 1:2 in ice-cold warfarin in acetonitrile solution (100 nM), and a centrifugation step (4°C, 2465 g for 20 min) to precipitate albumin from the matrix. Fenofibric acid was not used in the study, but merely controlled for during analysis as routine control of API degradation during lipolysis and sample storage. As no fenofibric acid could be detected in any samples, there was no attempt at quantification.
Data Analysis
Data are presented as mean values with standard deviation (n = 3, unless otherwise specified). Statistical analysis was performed in GraphPad Prism 7 (GraphPad Software, USA) using Student’s t test to evaluate differences between two groups, or a one-way ANOVA followed by a Tukey’s multiple comparison analysis test, to compare differences for more than two groups. Holm-Sidak’s multiple comparisons test was used when comparing against a control, as Tukey’s test does not support this. Two-way ANOVA was used to compare groups with two differing factors (formulation and barrier model). P-values <0.05 were considered statistically significant. Area under the curve (AUC) was calculated via a Python (version 3.6.5) script by fitting data to cubic splines using scipy.interpolate.CubicSpline and integrated using scipy.integrate.IntegrateQuad (SciPy version 1.1.0).
Formulation rankings between different assays was compared by normalizing AUC values of either donor, receiver, or plasma concentrations. The normalization was done by converting AUC values into percentages of the group sum, where 100% was defined as the sum of mean values in each respective group. The six groups were as follows: cell-free system donor samples with filter separation of phases (ENA/LiDo, this work); cell-free receiver samples (ENA/LiDo, this work); cell-based system donor samples with centrifugation separation of phases (ENA/Caco-2) (19); cell-based receiver samples (ENA/Caco-2) (19); single-compartment in vitro lipolysis samples with ultracentrifugation separation of phases (14); and in vivo plasma samples from pigs (14).
Apparent permeability coefficients (Papp) were calculated using the Solver tool in Microsoft Excel 2016 by non-linear least-squares regression of Eq. 1 (two-way flux model), where the assumption of sink-condition is not required (30).
1 |
where CR is the concentration (nmol/cm3) in the receiver compartment at time t (sec). M is the total amount (nmol) of analyte in the system available for permeation. CR,0 is the concentration of analyte in receiver compartment at t = 0. VD is the total volume (cm3) of the donor compartment, VR is the total volume (cm3) of the receiver compartment, and A is the total area (cm2) available for permeation between compartments. For the data analyzed in this work, M was assumed as the summed amount detected in aqueous fractions and receiver at each time point. M at t = 0 was assumed as the total amount added to the system.
Equation 1 approximates the system as being composed of two compartments, a donor and a receiver, with the lipid or cell membrane having little impact other than a rate-limiting effect that is described by Papp. However, depending on the analyte, the membrane can act as a discrete compartment and retain some of the permeating compound. This can be a large fraction of the total amount if the analyte has high affinity for the membrane constituents, and the receiver compartment is not a sufficiently effective sink. In cell-based systems, retention may also be a result of lysosomal trapping, which mainly basic compounds are at risk for due to the pH-driven entrapment (1,31). If the membrane retention is known, this fraction can be subtracted from the total amount of analyte in the system and the permeability coefficient adjusted accordingly. Furthermore, when comparing the permeability of a compound assayed in systems with differing filter support materials, the nominal porosity of the filter (ε) can affect Papp. The nominal porosity (ε) of the filter is approximately equal to the area of each pore (pore size), multiplied by the number of pores, and divided by the total area of the filter. A nominal porosity lower than unity therefore decreases the uncorrected Papp, as the available area for permeation is decreased. Multiplying the geometric area of the filter with the nominal porosity therefore describes the area that is available for permeation more accurately (Eq. 2).
2 |
where ℛ is the membrane retention factor (mol%), which herein was approximated from mass balance (total analyte recovered subtracted from amount added at start of experiment) at each data point used for fitting. According to the manufacturer, the nominal porosity is 0.70 for the Immobilon-P PVDF (0.45 μm pore size) filter used in this study. For the Transwell polycarbonate filters used in the Caco-2 study (19), the nominal porosity input was 0.16 in accordance with Matsson et al. (22).
Results
Integrity Assay with Static Digest Matrix
Samples taken from in vitro lipolysis at −5, 2, 3, 5, 13 and 30 min of digestion corresponded to mean values of 0, 18, 35, 46, 56, and 65% (n = 5) of complete digestion. Membrane integrity was maintained for one hour of exposure to digested media for 8 out of 21 conditions (Fig. 2). Four of the eight conditions with maintained membrane integrity were negative controls. The remaining four were the samples taken at −5 and 30 min of lipolysis (0 and 65% digestion) and applied to GIT-0 membranes with phosphate buffer ± BSA in the receiver (Fig. 2c–d). After two hours of exposure, only membranes exposed to negative controls and the two LBF samples applied to GIT-0 with phosphate buffer (no BSA) in receiver remained intact (Fig. S3, Supplementary Material), out of which only one had been subjected to digestion (30 min sample).
For HDMs subjected to LBF-containing media (Fig. 1a), only the dispersion-phase and late-stage digestion (30 min) samples were significantly differentiated from positive controls, but all samples were significantly different from negative controls. Based on these results, we concluded that HDMs were incompatible with triglyceride-containing LBFs. GIT-0 membranes (Fig. 2b–d) were more resilient, exhibiting mass transfers of LY that were significantly lower than the positive controls for all conditions containing LBFs. The composition of the receiver buffer was however observed to affect mass transfer. The Acceptor Sink Buffer, containing 1% (w/v) anionic surfactant (SDS), resulted in loss of integrity of GIT-0 membranes when exposed to LBF-containing media (Fig. 2b). Supplementation with 4% (w/w) protein (BSA) instead of SDS did not cause significantly different mass transfer of LY across GIT-0 (Fig. 2c) compared to plain phosphate buffer in the receiver (Fig. 2d). No lipid-polycarbonate filter combination could withstand the mid-stage digestion (5 min) samples for more than half an hour. These results deemed polycarbonate filter supports inappropriate for assays involving digestion and absorption.
Integrity Assay under Dynamic Digestion Conditions
Similar to what was observed with the static digestion matrix, polycarbonate-filter supported lipid membranes did not maintain an acceptable level of integrity for any suitable experiment length when porcine pancreatin was used as the digestive agent (Fig. 3a–b). In the dynamic setting, LiDo membranes could not be significantly differentiated from HDMs when applied to polycarbonate membranes and exposed to porcine pancreatin.
HDMs using PVDF filters for support showed a significantly greater mass transfer of LY during the digestion phase than polycarbonate-supported HDMs. Contrarily, LiDo on PVDF did not allow detectable levels of LY through the membrane for up to two hours, although an increase in donor compartment pH was observed after circa 90 min of digestion (Fig. S4, Supplementary Material). This pH rise can be regarded as an in situ marker for membrane integrity loss (19).
In Vitro Lipolysis and Permeation Assay of Loaded LBFs
Because of the high integrity of the LiDo/PVDF combination, it was used in the ENA device to further study whether and how this artificial membrane could identify promising formulations. Three different formulations loaded with fenofibrate were studied. Samples were taken from both compartments during 90 min of digestion. In a large proportion of the experiments, the LBFs containing digestible lipids (types IIIA-MC and LC) induced a sharp increase in mass transfer of fenofibrate after 30–60 min of digestion (Fig. 4a–c). The data from samples taken after 30 min of lipolysis were therefore excluded from comparisons (Fig. 4d). No corroborating increase in the mass transfer of the hydrophilic marker for integrity (LY) was evident.
The type IV formulation resulted in significantly lower concentrations of solubilized fenofibrate than types IIIA-MC or IIIA-LC (Fig. 5), which agrees with previously conducted in vitro lipolysis without absorption components (Fig. S5a–b, Supplementary Material) (14). Statistically significant differences of fenofibrate mass transfer between formulation types IV and IIIA-LC, and between IV and IIIA-MC, were also found. The formulation rank-order based on permeated fenofibrate was the same as the rank-order based on solubilized fenofibrate in the donor compartment.
Observed apparent permeability coefficients (Papp) indicated a high degree of similarity between type IIIA-MC and IIIA-LC LBFs (Table II). The type IV formulation was also in this regard different from the triglyceride-containing formulations, showing a significantly higher Papp (Fig. 6a). Re-analysis of data from previously conducted experiments with Caco-2 monolayers (19) revealed a similar relationship among the formulations, as well as a slight but significant difference in the magnitude of permeability between Caco-2 and LiDo models. The ratio between Caco-2 and LiDo permeability was on average 0.42. Correcting for mass balance to calculate retention adjusted values (Eq. 2) did not significantly affect the apparent relative difference between Caco-2 and LiDo (Fig. 6b). However, after adjusting for filter porosity (ε), the relationship between the two model systems was inverted and Caco-2 permeability on average 1.8-fold higher than that of LiDo (Fig. 6c).
Table II.
Uncorrecteda | Corrected for ℛb | Corrected for ℛ and εb | ||||
---|---|---|---|---|---|---|
Formulation | LiDo | Caco-2c | LiDo | Caco-2c | LiDo | Caco-2c |
IIIA-MC | 6.8 ± 2.1 | 3.1 ± 0.1 | 8.6 ± 2.9 | 3.6 ± 0.3 | 12.3 ± 4.1 | 22.6 ± 1.6 |
IIIA-LC | 6.4 ± 1.4 | 2.6 ± 0.5 | 7.8 ± 2.5 | 3.0 ± 0.7 | 11.1 ± 3.5 | 18.9 ± 4.2 |
IV | 14.5 ± 3.6 | 5.5 ± 1.6 | 15.6 ± 4.9 | 7.1 ± 2.8 | 22.3 ± 7.0 | 44.3 ± 17.7 |
Discussion
During the initial characterization process, two artificial membrane types were selected due to their ease of use, low cost, and extensive permeability characterization (1). Filters impregnated with hexadecane (HDMs) are among the simplest and most inexpensive artificial membranes available and have been used for permeability assessment previously (1,22,32). These are typically prepared on polycarbonate filter supports, where correct choice of pore size is important for maintaining membrane integrity (22). The interaction between the lipid membrane and its support material is clearly important for the artificial membrane to maintain barrier properties.
We initially assumed that HDMs could withstand contact with a lipolysis process, as hexadecane lacks ester groups that can be digested by pancreatic lipase (33). In this study, however, it became clear that HDMs could not retain their integrity for longer than 10 min during active digestion of LBFs by porcine pancreatin. Additionally, we showed that a dispersed triglyceride-containing LBF alone is sufficient to compromise HDM integrity. Switching to a more hydrophobic backing substrate (PVDF) did not improve the robustness of the model.
The GIT-0 model membrane is more complex in composition than HDM, due to the soy lecithin dissolved in n-dodecane. It was developed to be easy to use while allowing permeabilities for a wide range of drug compounds to be accurately predicted, and is marketed for measuring permeability coefficients (PAMPA) or use in drug release and absorption assays (μFlux/MacroFlux) (24,34,35). It therefore seemed a reasonable candidate for simultaneous lipolysis-permeation assays.
Unlike HDMs, which are typically prepared by solvent evaporation on polycarbonate substrate, GIT-0 is dispensed on top of a hydrophobic PVDF substrate and used within 10 min. Prepared HDMs that are ready for use appear dry, while GIT-0 membranes ready for use appear liquescent. At first glance, GIT-0 membranes might not seem resilient in a well-stirred system, but the results indicate that they are more resilient than HDMs. The interaction between the membrane-forming solution and the filter substrate material was also important. GIT-0 was ineffective on polycarbonate, but effective on PVDF. Furthermore, the in-house solution referred to as LiDo in this work, could not be distinguished from the commercially available GIT-0 solution in either function or composition (Fig. S2, Supplementary Material). For these reasons, LiDo applied to PVDF filter support was chosen as the preferred artificial membrane model for all further experiments.
To validate the model, three representative LBFs were selected for comparison. In vitro solubilized fractions, and absorbed/permeated fractions of fenofibrate among three different studies were compared: LiDo based lipolysis-permeation assay (this work), conventional in vitro lipolysis and in vivo plasma profiles (14), as well as the Caco-2 based lipolysis-permeation assay (19). For in vitro solubilized fractions, the ranking of the formulations is the same, despite some differences in experimental protocol (phase separation methods, digestive agents, media composition, and pH). However, re-analyzing data from (19) showed significantly higher relative aqueous levels of fenofibrate with the type IV formulation in the Caco-2 based lipolysis-permeation assay (Fig. S5, Supplementary Material), compared the LiDo based assay used in this work and the conventional in vitro lipolysis assay (14).
As shown in the Results, an inflection point in the flux of fenofibrate was seen in several experiments after approximately 30 min of digestion. It is likely that the LiDo membranes eventually suffer some damage from the formulations or their digestion products, leading to an increased mass transfer of the model drug. To judge from the lack of pH change in the donor medium or noticeable LY mass transfer to the receiver, the damage does not seem to be extensive enough to form aqueous pores in the membrane. The structure of LiDo or GIT-0 membranes is not known, however Assmus et al. proposed a model structure for a similar system (9% w/w egg lecithin in n-dodecane) based on NMR experiments (36). In this model, the dodecane envelops the PVDF filter support and the amphiphilic lecithin constituents form monolayers on either side, bridging the oil-water interfaces. Reverse micelles are proposed as carriers of hydrophilic compounds within and across the artificial membrane, whereas lipophilic compounds can diffuse across through the dodecane. Insertion of free fatty acids or lysophospholipids generated by digestion might alter the spontaneous curvature of the monolayer at the oil-water interface. Conceivably, this could lead to formation of narrow aqueous pores with net negative surface charge. As LY carries permanent negative charge, whereas fenofibrate is uncharged, electrostatic repulsion might explain the lack of a simultaneous inflection point for LY. The absence of spontaneous pH increase in the donor medium is more difficult to explain if aqueous pores are indeed formed within this period. However, partially formed pores or indentations would increase the apparent permeability of fenofibrate with decreasing height of the membrane.
With the exclusion of data measured at time points longer than 30 min, significant fenofibrate mass transfer differences between the formulations were still observed in the LiDo-based in vitro model. These results are at odds with those of Keemink et al. (19) and Griffin et al. (14) who assayed the formulations utilizing Caco-2 cell and landrace pig models, respectively. A difference can also be seen when comparing rank-order of the formulations between different models (Fig. 5), which indicates that the LiDo-based in vitro model with porcine pancreatin is more similar to the conventional single-compartment in vitro lipolysis model than the assays utilizing living tissue.
The observed effect of the formulations on the apparent permeability of fenofibrate do however indicate some underlying similarity between the LiDo and Caco-2 based models. After applying corrections for membrane retention and filter porosity, the permeability in the Caco-2 model was on average higher than that in the LiDo model. The height of the excess lipid on either side of the filter can be calculated from the volume added and the geometric properties of the filter in accordance with Nielsen & Avdeef (39). For the setting applied in this study, this results in a total height of 192–206 μm for LiDo membrane and PVDF filter through which a molecule must diffuse between donor and receiver compartments, excluding unstirred water layers. The filter height is approximately 100–145 μm for the PVDF filters in this study, and 10–20 μm for the polycarbonate Transwell filters used in the Caco-2 study (19) according to manufacturers. The height of Caco-2 cells can vary between 11 and 33 μm depending on the culturing protocol that is used and the source of the cells (37,38). This gives a total height or diffusion distance of 21–42 μm for a Caco-2 monolayer. The ratio between these distances given by each model is 4–9. As seen from the corrected permeability coefficients in Table II, the observed ratio (1.8) is approximately half of what could be expected from an approach purely based on the diffusion distance. While a more detailed analysis might yield somewhat different results, differences in the number of partitioning steps could in part explain the discrepancy.
Formulation ranking based on apparent permeability was inversely correlated with that of the solubilized concentrations over time in both models, Papp ranking by LBF type: IV > IIIA-MC ≈ IIIA-LC (Fig. 6a–c). If the solubilized drug concentration were the sole governing factor of mass transfer, Papp would be the same with all formulations. As the free fraction of fenofibrate is unknown in the tested systems, the true apparent permeability cannot be determined. Nevertheless, the similarity in ranking between the two models, based on Papp, strengthens the idea that LiDo is functionally similar to Caco-2 in terms of passive permeability of fenofibrate, even under lipolysis conditions. Thus, LiDo cannot be discounted as a relevant lipid support to use for lipolysis-permeation assays, but the underlying issue causing relative mass transfer differences between the formulations tested here must be identified and remedied.
The simultaneous lipolysis-permeation assay with an artificial membrane was to our knowledge first attempted successfully in the work of Bibi et al. (40). They investigated the use of Permeapad, a phospholipid-based solid membrane sandwiched in-between two support sheets. In the study, an impressive durability of the membrane was demonstrated, where integrity could be retained for at least 24 h. However, the low mass transfer rates permitted by the Permeapad membrane is not ideal for assaying a system where thermodynamic stability is low such as a lipid-digestion driven, supersaturated system. It would require long assay times to reach quantifiable concentrations in the receiver compartment with the risk that rapid changes in saturation levels are missed. In contrast, the LiDo-based model membrane permits a more in vivo-like flux of the model drug fenofibrate. Under comparable conditions, the flux of fenofibrate over LiDo was on average 334-fold higher than the flux of cinnarizine over Permeapad. To summarize, Permeapad certainly displays impressive resilience to lipolysis conditions, and is certainly valuable for easy to use and cost-effective assays of thermodynamically stable systems. LiDo appears more suitable for fast assays of systems with rapid kinetics such as those with low thermodynamic stability.
In terms of realistic flux, the LiDo membrane permitted a similar flux as Caco-2. Based on the expected permeability of fenofibrate in human small intestine (17), the flux could be expected to be 10-fold higher in vivo. Dispersed LBFs are in most cases thermodynamically unstable systems, especially when submitted to lipolysis. The fraction absorbed is therefore a function of precipitation versus absorption of the API versus the residence time of the drug in the intestinal tract. In a well-stirred system, the precipitated API might redissolve and be absorbed if the membrane flux is sufficient. An artificially low flux will not provide sufficient biorelevance to produce meaningful results that capture the solubility-permeability interplay. The high flux over LiDo in the ENA system is likely due to the liquescent membrane structure, relatively large surface area and efficient stirring.
Fenofibrate is a highly permeable compound (17,41,42) and to our knowledge not actively transported. The observed differences in mass transfer ranking between the Caco-2 and LiDo-based models are therefore unlikely to have been caused by paracellular or facilitated transport occurring in the cell-based model. The most likely scenario is that the solubilized concentrations give a false indication of permeability that depends on the formulation used. Instead, the interactions of fenofibrate with the formulations is likely the important factor for mass transfer. At this point however, we cannot exclude that the formulations to some extent interact with the membranes. Both these factors – fenofibrate interaction with colloidal structures formed by the formulations and formulations potentially interacting with the membrane – are nonetheless highly likely to be influenced by the digestion of the formulations. They are therefore dependent on the digestive agent used, a parameter that is different between the LiDo and Caco-2 based lipolysis-permeation assays compared in this work.
In this instance, we have little reason to believe that the observed differences in mass transfer between models are the result of the membranes used. If the flux across the LiDo-based model membrane were significantly lower than that of Caco-2 for instance, we would have reason to assume that supersaturation kinetics could be a cause behind the observed differences. In our study, the flux was higher over the artificial membrane than over the cell-based. As discussed by Stillhart et al. (18), the absorption of lipolysis products can affect the supersaturation ratio of the drug if they are absorbed faster than the drug. A possible explanation could therefore exist if lipolysis products are absorbed to a much greater degree in the cell-based assay or in vivo. This would proportionally lower the solubilizing capacity of the type IIIA LBFs and make them more similar to the type IV.
Conclusion
In this study, artificial membranes were studied to evaluate their use in predicting the performance of LBFs in lipolysis-permeation assays. Hexadecane membranes were found unsuitable for use with triglyceride-containing LBFs. Lecithin-based membranes (LiDo) with PVDF filter support were compatible with the formulations and the commonly used porcine pancreatin. The results of the study are inconclusive regarding the suitability of LiDo in the lipolysis-permeation assay. The model drug and formulations assayed, with porcine pancreatin as digestive agent, produced the same results as the state-of-the-art in vitro lipolysis assay. Further studies are required to characterize physical changes of membrane structure during digestion of LBFs, and investigate the cause of mass-transfer differences between the LiDo-based and the Caco-2 cell-based method. Due to the minimal incubation time required in this method, we expect that it could also be suitable for cell-free head-to-head comparisons of other supersaturating formulations, such as amorphous solid dispersions.
Electronic supplementary material
Acknowledgements
This work was supported by European Research Council Grant 638965. We thank Janneke Keemink and Valentina Bianco for performing the μFlux experiments for GIT-0 and LiDo comparison. We also thank Andrea Treyer for assistance with phospholipid mass-spectrometry analysis.
Abbreviations
- API
Active Pharmaceutical Ingredient
- AUC
Area Under the Curve
- BCS
Biopharmaceutics Classification System
- BSA
Bovine Serum Albumin
- DS-PAMPA
Double-Sink Parallel Artificial Membrane Permeability Assay
- FaSSIF
Fasted State Simulated Intestinal Fluid
- HDM
Hexadecane Membrane
- IVIVR
In Vitro In Vivo Relationship
- LBF
Lipid-Based Formulation
- LC
Long-Chain
- LiDo
Lecithin-in-Dodecane
- LY
Lucifer Yellow
- MC
Medium-Chain
- NME
New Molecular Entity
- SDS
Sodium Dodecyl Sulfate
- PB
Phosphate Buffer
- PBS
Phosphate Buffered Saline
- PVDF
Polyvinylidene Difluoride
Funding Information
Open access funding provided by Uppsala University.
Footnotes
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Avdeef A. The rise of PAMPA. Expert Opin Drug Metab Toxicol. 2005;1(2):325–342. doi: 10.1517/17425255.1.2.325. [DOI] [PubMed] [Google Scholar]
- 2.U.S. Food and Drug Administration. New drugs at FDA: CDER’s new molecular entities and new therapeutic biological products [Internet]. [cited 2019 Dec 16]. Available from: www.fda.gov/Drugs/DevelopmentApprovalProcess/DrugInnovation/
- 3.Savla R, Browne J, Plassat V, Wasan KM, Wasan EK. Review and analysis of FDA approved drugs using lipid-based formulations. Drug Dev Ind Pharm. 2017;43(11):1743–1758. doi: 10.1080/03639045.2017.1342654. [DOI] [PubMed] [Google Scholar]
- 4.Müllertz A, Ogbonna A, Ren S, Rades T. New perspectives on lipid and surfactant based drug delivery systems for oral delivery of poorly soluble drugs: lipid and surfactant drug delivery systems. J Pharm Pharmacol. 2010;62(11):1622–1636. doi: 10.1111/j.2042-7158.2010.01107.x. [DOI] [PubMed] [Google Scholar]
- 5.Kamboj S, Sethi S, Rana V. Lipid based delivery of Efavirenz: an answer to its erratic absorption and food effect. Eur J Pharm Sci. 2018;123:199–216. doi: 10.1016/j.ejps.2018.07.037. [DOI] [PubMed] [Google Scholar]
- 6.Kazi M, Al-Swairi M, Ahmad A, Raish M, Alanazi FK, Badran MM, et al. Evaluation of self-Nanoemulsifying drug delivery systems (SNEDDS) for poorly water-soluble Talinolol: preparation, in vitro and in vivo assessment. Front Pharmacol. 2019;10:459. doi: 10.3389/fphar.2019.00459. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Shin D, Chae B, Goo Y, Yoon H, Kim C, Sohn S, Oh D, Lee A, Song S, Choi Y. Improved dissolution and Oral bioavailability of valsartan using a solidified Supersaturable self-microemulsifying drug delivery system containing Gelucire® 44/14. Pharmaceutics. 2019;11(2):58. doi: 10.3390/pharmaceutics11020058. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Cherniakov I, Izgelov D, Barasch D, Davidson E, Domb AJ, Hoffman A. Piperine-pro-nanolipospheres as a novel oral delivery system of cannabinoids: pharmacokinetic evaluation in healthy volunteers in comparison to buccal spray administration. J Control Release. 2017;266:1–7. doi: 10.1016/j.jconrel.2017.09.011. [DOI] [PubMed] [Google Scholar]
- 9.Alskär LC, Parrow A, Keemink J, Johansson P, Abrahamsson B, Bergström CAS. Effect of lipids on absorption of carvedilol in dogs: is coadministration of lipids as efficient as a lipid-based formulation? J controlled release. Apr. 2019;304:90–100. doi: 10.1016/j.jconrel.2019.04.038. [DOI] [PubMed] [Google Scholar]
- 10.Thomas N, Richter K, Pedersen TB, Holm R, Müllertz A, Rades T. In vitro lipolysis data does not adequately predict the in vivo performance of lipid-based drug delivery systems containing Fenofibrate. AAPS J. 2014;16(3):539–549. doi: 10.1208/s12248-014-9589-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Siqueira Jørgensen S, Rades T, Mu H, Graeser K, Müllertz A. Exploring the utility of the chasing principle: influence of drug-free SNEDDS composition on solubilization of carvedilol, cinnarizine and R3040 in aqueous suspension. Acta Pharm Sin B. 2019;9(1):194–201. doi: 10.1016/j.apsb.2018.07.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Council of Europe. Chapter 2.9.3. Dissolution test for solid dosage forms. In: European Pharmacopeia. 9.5. Strasbourg: Council of Europe; 2018.
- 13.Larsen AT, Åkesson P, Juréus A, Saaby L, Abu-Rmaileh R, Abrahamsson B, Østergaard J, Müllertz A. Bioavailability of Cinnarizine in dogs: effect of SNEDDS loading level and correlation with Cinnarizine Solubilization during in vitro lipolysis. Pharm Res. 2013;30(12):3101–3113. doi: 10.1007/s11095-013-1145-x. [DOI] [PubMed] [Google Scholar]
- 14.Griffin BT, Kuentz M, Vertzoni M, Kostewicz ES, Fei Y, Faisal W, Stillhart C, O’Driscoll CM, Reppas C, Dressman JB. Comparison of in vitro tests at various levels of complexity for the prediction of in vivo performance of lipid-based formulations: case studies with fenofibrate. Eur J Pharm Biopharm. 2014;86(3):427–437. doi: 10.1016/j.ejpb.2013.10.016. [DOI] [PubMed] [Google Scholar]
- 15.Feeney OM, Crum MF, McEvoy CL, Trevaskis NL, Williams HD, Pouton CW, et al. 50 years of oral lipid-based formulations: provenance, progress and future perspectives. Adv Drug Deliv Rev. 2016;101:167–194. doi: 10.1016/j.addr.2016.04.007. [DOI] [PubMed] [Google Scholar]
- 16.Elkhabaz A, Moseson DE, Brouwers J, Augustijns P, Taylor LS. Interplay of Supersaturation and Solubilization: lack of correlation between concentration-based Supersaturation measurements and membrane transport rates in simulated and aspirated human fluids. Mol Pharm. 2019;16(12):5042–5053. doi: 10.1021/acs.molpharmaceut.9b00956. [DOI] [PubMed] [Google Scholar]
- 17.Fei Y, Kostewicz ES, Sheu M-T, Dressman JB. Analysis of the enhanced oral bioavailability of fenofibrate lipid formulations in fasted humans using an in vitro–in silico–in vivo approach. Eur J Pharm Biopharm. 2013;85(3):1274–1284. doi: 10.1016/j.ejpb.2013.03.001. [DOI] [PubMed] [Google Scholar]
- 18.Stillhart C, Imanidis G, Griffin BT, Kuentz M. Biopharmaceutical modeling of drug Supersaturation during lipid-based formulation digestion considering an Absorption sink. Pharm Res. 2014;31(12):3426–3444. doi: 10.1007/s11095-014-1432-1. [DOI] [PubMed] [Google Scholar]
- 19.Keemink J, Mårtensson E, Bergström CAS. A lipolysis-permeation setup for simultaneous study of digestion and absorption in vitro. Mol Pharm. 2019;16(3):921–930. doi: 10.1021/acs.molpharmaceut.8b00811. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Keemink J, Bergström CAS. Caco-2 cell conditions enabling studies of drug Absorption from digestible lipid-based formulations. Pharm Res. 2018;35(4):74. doi: 10.1007/s11095-017-2327-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Bu P, Ji Y, Narayanan S, Dalrymple D, Cheng X, Serajuddin ATM. Assessment of cell viability and permeation enhancement in presence of lipid-based self-emulsifying drug delivery systems using Caco-2 cell model: Polysorbate 80 as the surfactant. Eur J Pharm Sci. 2017;99:350–360. doi: 10.1016/j.ejps.2016.12.018. [DOI] [PubMed] [Google Scholar]
- 22.Matsson P, Bergström CAS, Nagahara N, Tavelin S, Norinder U, Artursson P. Exploring the role of different drug transport routes in permeability screening. J Med Chem. 2005;48(2):604–613. doi: 10.1021/jm049711o. [DOI] [PubMed] [Google Scholar]
- 23.Avdeef A. Absorption and Drug Development: Solubility, Permeability, and Charge State [Internet]. 1st ed. Wiley; 2003 [cited 2020 Mar 24]. Available from: https://onlinelibrary.wiley.com/doi/book/10.1002/047145026X
- 24.Avdeef A, Nielsen PE, Du CM. Method and apparatus for improving in vitro measurement of membrane permeability of chemical compounds. US patent; 7,022,528, 2006.
- 25.Alskär LC, Keemink J, Johannesson J, Porter CJH, Bergström CAS. Impact of drug physicochemical properties on lipolysis-triggered drug Supersaturation and precipitation from lipid-based formulations. Mol Pharm. 2018;15(10):4733–4744. doi: 10.1021/acs.molpharmaceut.8b00699. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Williams HD, Sassene P, Kleberg K, Bakala-N’Goma J-C, Calderone M, Jannin V, et al. Toward the establishment of standardized in vitro tests for lipid-based formulations, part 1: method parameterization and comparison of in vitro digestion profiles across a range of representative formulations. J Pharm Sci. 2012;101(9):3360–3380. doi: 10.1002/jps.23205. [DOI] [PubMed] [Google Scholar]
- 27.Pouton CW. Formulation of poorly water-soluble drugs for oral administration: physicochemical and physiological issues and the lipid formulation classification system. Eur J Pharm Sci. 2006;29(3–4):278–287. doi: 10.1016/j.ejps.2006.04.016. [DOI] [PubMed] [Google Scholar]
- 28.Juenemann D, Jantratid E, Wagner C, Reppas C, Vertzoni M, Dressman JB. Biorelevant in vitro dissolution testing of products containing micronized or nanosized fenofibrate with a view to predicting plasma profiles. Eur J Pharm Biopharm. 2011;77(2):257–264. doi: 10.1016/j.ejpb.2010.10.012. [DOI] [PubMed] [Google Scholar]
- 29.Stillhart C, Imanidis G, Kuentz M. Insights into drug precipitation kinetics during in vitro digestion of a lipid-based drug delivery system using in-line Raman spectroscopy and mathematical modeling. Pharm Res. 2013;30(12):3114–3130. doi: 10.1007/s11095-013-0999-2. [DOI] [PubMed] [Google Scholar]
- 30.Tavelin S, Gråsjö J, Taipalensuu J, Ocklind G, Artursson P. Applications of epithelial cell culture in studies of drug transport. In: wise C, editor. Epithelial cell culture protocols [internet]. Totowa, NJ: Humana press; 2002. p. 233–72. Available from: 10.1385/1-59259-185-X:233. [DOI] [PubMed]
- 31.Avdeef A, Strafford M, Block E, Balogh MP, Chambliss W, Khan I. Drug absorption in vitro model: filter-immobilized artificial membranes: 2. Studies of the permeability properties of lactones in Piper methysticum Forst. Eur J Pharm Sci. 2001;14(4):271–280. doi: 10.1016/S0928-0987(01)00191-9. [DOI] [PubMed] [Google Scholar]
- 32.Wohnsland F, Faller B. High-throughput permeability pH profile and high-throughput alkane/water log P with artificial membranes. J Med Chem. 2001;44(6):923–930. doi: 10.1021/jm001020e. [DOI] [PubMed] [Google Scholar]
- 33.Mendes AA, Oliveira PC, de Castro HF. Properties and biotechnological applications of porcine pancreatic lipase. J Mol Catal B Enzym. 2012;78:119–134. doi: 10.1016/j.molcatb.2012.03.004. [DOI] [Google Scholar]
- 34.Li J, Tsinman K, Tsinman O, Wigman L. Using pH gradient dissolution with in-situ flux measurement to evaluate bioavailability and DDI for formulated poorly soluble drug products. AAPS PharmSciTech. 2018;19(7):2898–2907. doi: 10.1208/s12249-018-1164-3. [DOI] [PubMed] [Google Scholar]
- 35.Bermejo M, Avdeef A, Ruiz A, Nalda R, Ruell JA, Tsinman O, González I, Fernández C, Sánchez G, Garrigues TM, Merino V. PAMPA—a drug absorption in vitro model. Eur J Pharm Sci. 2004;21(4):429–441. doi: 10.1016/j.ejps.2003.10.009. [DOI] [PubMed] [Google Scholar]
- 36.Assmus F, Ross A, Fischer H, Seelig J, Seelig A. 31 P and 1 H NMR studies of the molecular Organization of Lipids in the parallel artificial membrane permeability assay. Mol Pharm. 2017;14(1):284–295. doi: 10.1021/acs.molpharmaceut.6b00889. [DOI] [PubMed] [Google Scholar]
- 37.Wilson G, Hassan IF, Dix CJ, Williamson I, Shah R, Mackay M, Artursson P. Transport and permeability properties of human Caco-2 cells: an in vitro model of the intestinal epithelial cell barrier. J Control Release. 1990;11(1–3):25–40. doi: 10.1016/0168-3659(90)90118-D. [DOI] [Google Scholar]
- 38.Moyes SM, Morris JF, Carr KE. Culture conditions and treatments affect Caco-2 characteristics and particle uptake. Int J Pharm. 2010;387(1–2):7–18. doi: 10.1016/j.ijpharm.2009.11.027. [DOI] [PubMed] [Google Scholar]
- 39.Nielsen PE, Avdeef A. PAMPA—a drug absorption in vitro model: 8. Apparent filter porosity and the unstirred water layer. Eur J Pharm Sci. 2004;22(1):33–41. doi: 10.1016/j.ejps.2004.02.003. [DOI] [PubMed] [Google Scholar]
- 40.Bibi HA, Holm R, Bauer-Brandl A. Simultaneous lipolysis/permeation in vitro model, for the estimation of bioavailability of lipid based drug delivery systems. Eur J Pharm Biopharm. 2017;117:300–307. doi: 10.1016/j.ejpb.2017.05.001. [DOI] [PubMed] [Google Scholar]
- 41.Berthelsen R, Byrialsen JP, Holm R, Jacobsen J, Abrahamsson B, Saabye L, Madelung P, Müllertz A. Development of a μDissolution-permeation model with in situ drug concentration monitoring. J Drug Deliv Sci Technol. 2016;35:223–233. doi: 10.1016/j.jddst.2016.06.013. [DOI] [Google Scholar]
- 42.Berben P, Brouwers J, Augustijns P. Assessment of passive intestinal permeability using an artificial membrane insert system. J Pharm Sci. 2018;107(1):250–256. doi: 10.1016/j.xphs.2017.08.002. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.