Abstract

Thiophenol as a highly toxic compound can harm the environment and living organisms and thus demands effective detection. In this work, we presented a near-infrared fluorescent probe (DAPH-DNP) for detecting thiophenol according to the ESIPT mechanism using 2,4-dinitrophenyl group as a recognition unit. This probe displayed specificity toward thiophenol over other related analytes. Meanwhile, there was good linearity between the relative fluorescence intensity of DAPH-DNP and the concentration of thiophenol in the range of 0–80 μM. This probe also showed a low detection limit of 3.8 × 10–8 and a marked Stokes shift (192 nm). Further, this probe could be used for monitoring thiophenol in environmental water samples and imaging thiophenol in living cells, which indicated that this probe had a real application in the environment and living organisms.
1. Introduction
Thiophenol plays important roles in pharmaceutical industries and manufacturing agrochemical.1−3 However, the potential hazards of thiophenol to the biological and ecological environments cannot be non-negligible due to its high toxicity. For instance, the LC50 of thiophenol for fish is in the range of 0.01–0.4 mM.4 The LD50 of thiophenol is 25 mg/kg for mice, 24 mg/kg for birds,5 and 46 mg/kg for rats.6 Moreover, thiophenol can be absorbed by skin contact and inhalation, which can result in many diseases including muscular weakness, central nerve injury, nausea, coma, vomiting, shortness of breath, and even death.7,8 For this reason, thiophenol is recognized by the USEPA as a prioritized pollutant.3,9 Hence, it is of great significance to develop effective methods for monitoring thiophenol in the environment and biological systems.
The traditional methods, such as high-performance liquid chromatography (HPLC),10 gas chromatography–mass spectrometry (GC–MS),11 and UV,12 have been established for thiophenol detection in the environment. Although these methods have displayed good reproducibility and accuracy toward thiophenol, they are unsuitable for detection of thiophenol in living samples owing to the needs of high cell or tissue destruction. By contrast, fluorescent-based probes have great potential applications in both environmental and biological systems because of their high sensitivity, simplicity, lower detection limits, and nondestructive detection.13−20 However, development of fluorescent probes for thiophenol is extremely challenging to differentiate thiophenol from thiols due to similar chemical properties between thiophenol and thiols. Fortunately, since the pioneer work of distinguishing thiophenol and thiols from Wang,21 a number of probes have been developed based 2,4-dinitrobenzenesulfonate and dinitrophenyl ether recognition groups.22−43 Although those probes worked well, many limitations in practical use remain to be overcome. For example, some probes could suffer from slow response (>10 min) or need of surfactants to accelerate the reactions, which was a disadvantage for real-time detection. Some probes might be subject to a small Stokes shift (<100 nm), which was defects for sensitivity determination and bioimaging due to the self-absorption interference. Furthermore, most of the reported thiophenol fluorescent probes emitted in the short-wavelength region (in blue or yellow emission), which was capable of limitations in biological imaging due to the interference by background autofluorescence of living cells and organisms. Near-infrared (NIR) fluorescent probes with long-wavelength emissions are ideal tools for overcoming the above-mentioned problems, which has unique advantages including minimum interference of the background, decreased photodamage to biological samples, and deep tissue penetration.44−46 Meanwhile, the fluorescent probes with large Stokes shift can reduce the interferences induced by autofluorescence or self-absorption and then improve the detection accuracy and sensitivity due to the major shifts separated emission and excitation bands, which is suitable for fluorescence imaging.47−57 Based on the current studies, only few probes for thiophenol detection having all the above-mentioned merits have been reported. Therefore, development of fast-responding, excellent selectivity, and NIR fluorescent probes with large Stokes shift for monitoring thiophenol are still highly demanded.
Based on these analyses, a novel NIR and ESIPT fluorescent probe (2E,4E)-5-(4-(dimethylamino)phenyl)-1-(2-(2,4-dinitrophenoxy)phenyl)penta-2,4-dien-1-one (DAPH-DNP) was designed and synthesized for the selective and real-time detection of thiophenol, in which a 2,4-dinitrophenyl (DNP) group was used as a thiophenol recognition unit and (2E,4E)-5-(4-(dimethylamino)phenyl)-1-(2-hydroxyphenyl)penta-2,4-dien-1-one (DAPH) was utilized as a fluorophore (Scheme 1). The DAPH dye with an electron-donor group N,N-dimethylamino and o-hydroxyacetophenone was selected as a fluorescence signaling unit due to its salient characteristics including large Stokes shift, emission in the NIR region, ESIPT properties, and easy synthetic modification. In the probe DAPH-DNP, 2,4-dinitrophenyl group was attached to the hydroxyl site, which resulted in fluorescence quenching due to the hampering of the ESIPT process. However, the nucleophilic substitution of dinitrophenyl ether mediated by thiophenol would release the hydroxyl group and thus ESIPT process produced by formed the intramolecular hydrogen bonds between carbonyl oxygen and the hydroxyl group, accompanied with the strong electron-donating group N,N-dimethylamino, the probe DAPH-DNP generated NIR fluorescence emission. Indeed, the NIR probe showed excellent sensitivity, good selectivity, fast response rate, and large Stokes shift for thiophenol detection. More importantly, the probe DAPH-DNP was successfully used for thiophenol detection in water samples and living cells, which suggested its practical application in environment and biology. To the best of our knowledge, no NIR and ESIPT fluorescent probe for thiophenol has been reported.
Scheme 1. Proposed Mechanism of the Detection of Thiophenol by DAPH-DNP.

2. Results and Discussion
2.1. Sensing Properties of DAPH-DNP for PhSH
To verify whether DAPH-DNP has sensing ability for PhSH, spectral properties of DAPH-DNP before and after the addition of thiophenol were tested in phosphate-buffered saline (PBS) solution (50 mM, pH 7.4, with 10% N,N-dimethylformamide (DMF)). As shown in Figure 1, the probe DAPH-DNP itself exhibited a maximal absorption peak at 447 nm. When thiophenol was added to the solution of DAPH-DNP, the absorption band at 447 nm disappeared. At the same time, a new peak at 462 nm appeared. As a result, it implicated that thiophenol can result in a structural change in DAPH-DNP.
Figure 1.

UV–vis absorption spectrum of DAPH-DNP in the absence (a) or presence (b) of thiophenol in PBS solution (50 mM, pH 7.4, with 10% DMF).
For the purpose to gain further insight into DAPH-DNP for detecting thiophenol, the fluorescence response of DAPH-DNP toward thiophenol was examined in PBS solution (50 mM, pH 7.4, with 10% DMF). As shown in Figure 2, the emission intensity of DAPH-DNP was negligible in the buffer solution, which was attributed to the protection of phenol with the 2,4-dinitrophenyl group. When thiophenol was added, an obvious fluorescence emission band was observed at 654 nm. With continued addition thiophenol, the normalized fluorescence intensity of DAPH-DNP system at 654 nm was gradually enhanced. This result, mainly owing to the cleavage reaction of thiophenol, released the phenol and ESIPT process appeared. Moreover, a good linear relationship between the concentration of thiophenol (0–80 μM) and the normalized fluorescence intensity at 654 nm was acquired. Simultaneously, the normalized fluorescence intensity of the DAPH-DNP solution increased up to 27-fold when the concentration of thiophenol was 80 μM. The limit of detection was calculated to be 3.8 × 10–8, which showed that DAPH-DNP had high sensitivity for thiophenol. Therefore, DAPH-DNP can be used for quantitatively monitoring thiophenol. Compared with other reported probes (Table 1), this probe has advantages for thiophenol detection including NIR fluorescence emission, large Stokes shift, and relatively large linear range.
Figure 2.
(a) Fluorescence emission spectra of DAPH-DNP (10 μM) in the presence of different concentrations of thiophenol in PBS solution (50 mM, pH 7.4, with 10% DMF). (b) Linear correlation between the normalized fluorescence intensity at 654 nm and thiophenol concentration. λex = 462 nm.
Table 1. Comparison of DAPH-DNP with Other Probes for Thiophenol.
2.2. Selectivity and Competition
Selectivity is an important parameter to evaluate the performance of a new probe. To demonstrate the selectivity of DAPH-DNP, we investigated the fluorescent response of DAPH-DNP toward relevant species such as (PhSH, p-CH3O-PhSH, p-NH2-PhSH, p-CH3-PhSH, phenol, aniline, Gly, Hcy, Cys, GSH, NaClO, NaHS, H2O2, KSCN, NaNO2, NaBr, KI, NaHSO3, NaN3). As shown in Figure 3a, the introduction of thiophenol leads to a remarkable fluorescence enhancement at 654 nm, whereas negligible fluorescence was observed after incubation with other relevant species. These results indicated that DAPH-DNP can selectively for recognition.
Figure 3.
Fluorescence response of DAPH-DNP (10 μM) to the relevant analytes in PBS solution (50 mM, pH 7.4, with 10% DMF). (1) Bank; (2) PhSH; (3) p-CH3O-PhSH; (4) p-NH2-PhSH; (5) p-CH3-PhSH; (6) phenol; (7) aniline; (8) Gly; (9) Hcy; (10) Cys; (11) GSH; (12) NaClO; (13) NaHS; (14) H2O2; (15) KSCN; (16) NaNO2; (17) NaBr; (18) KI; (19) NaHSO3; and (20) NaN3. (B) Fluorescent responses of DAPH-DNP (10 μM) to PhSH (100 μM) in the presence of various analytes in PBS solution (50 mM, pH 7.4, with 10% DMF). (1) PhSH + phenol; (2) PhSH + aniline; (3) PhSH + Gly; (4) PhSH + Hcy; (5) PhSH + Cys; (6) PhSH + GSH; (7) PhSH + NaClO; (8) PhSH + NaHS; (9) PhSH + H2O2; (10) PhSH + KSCN; (11) PhSH + NaNO2; (12) PhSH + NaBr; (13) PhSH + KI; (14) PhSH + NaHSO3; and (15) PhSH + NaN3. λex = 462 nm.
To study the anti-interference performance of DAPH-DNP as a thiophenol selective probe, DAPH-DNP to thiophenol was carried out with the coexistence of different individual species. As shown in Figure 3b, the fluorescence intensity of DAPH-DNP solution at 654 nm had no obviously identical to that in the case of thiophenol alone by coexisting thiophenol and other species. The combined results suggested that DAPH-DNP possesses strong anti-interference ability for the detection of thiophenol.
2.3. Effect of pH on DAPH-DNP
The effects of pH on the emission profile of DAPH-DNP were further investigated in the presence and absence of thiophenol. As shown in Figure 4, the normalized emission intensity of the DAPH-DNP solution at 654 nm displayed negligible changes over a wide pH range from 1.0 to 12.0, which indicated that DAPH-DNP was not affected by the pH value. However, the normalized fluorescence intensity of DAPH-DNP system at 654 nm displayed enhancement at pH between 4.0 and 7.0 in the presence of thiophenol, exhibited the maximum normalized fluorescence intensity at pH 7.0, and remained unchanged at pH >7.0. This result, mainly due to the nucleophilic substitution reaction of thiophenol with dinitrophenyl ether, does not occur under strong acidic conditions. A physiological pH of 7.4 implies that DAPH-DNP has potential application in biological systems.
Figure 4.

Fluorescence intensity at 654 nm with different incubation times in the absence (a) or presence (b) of thiophenol in PBS solution (50 mM, pH 7.4, with 10% DMF). λex = 462 nm.
2.4. Response Time of DAPH-DNP to PhSH
The time-dependent fluorescence intensities of DAPH-DNP were also determined before and after the addition of thiophenol. As shown in Figure 5, in the absence of thiophenol, the fluorescence intensity of the DAPH-DNP solution at 654 nm did not change with the increase of time, indicating that DAPH-DNP was stable. By contrast, with the introduction of thiophenol, the DAPH-DNP solution at 654 nm exhibited a fluorescence enhancement with time and became constant after about 6 min. The rapid response explained that DAPH-DNP can monitor thiophenol in real time.
Figure 5.

Fluorescence changes in DAPH-DNP under various pH conditions in the absence (a) or presence (b) of thiophenol. λex = 462 nm.
2.5. Mechanism Study
It is known that dinitrophenyl ether can convert to phenol by a thiophenol-triggered nucleophilic substitution reaction. To confirm the mechanism of sensitivity of DAPH-DNP for thiophenol, the reaction product of DAPH-DNP with thiophenol was obtained and subject to 1H NMR. As shown in Figure S1, DAPH-DNP displayed three proton signals at 8.80, 8.24, and 7.19 ppm, which were attributable to the dinitrophenyl group. Those proton signals in DAPH-DNP disappeared, and a new peak of phenol (13.16 ppm) appeared in the presence of thiophenol (Figure S4), indicating that thiophenol caused the removal of dinitrophenyl group and the release of DAPH. After the addition of thiophenol, the high-resolution mass spectrometry (HRMS) spectrum showed a peak at m/z = 294.1493 (Figure S5), corresponding to DAPH (calcd C19H19NO2 [M + H]+, 294.3597). The data supported the responding mechanism as displayed in Scheme 1.
2.6. Application of DAPH-DNP in Water Samples
Considering the potential pollution of thiophenol to the environment, we employed DAPH-DNP to monitor thiophenol in the water samples from Yuanjiang River and tap water in Changde city to investigate its practicability in environmental science. As shown in Table S1, there was a good recovery of thiophenol in the range from 97.0 to 103% in the water sample, indicating that DAPH-DNP is suitable for the detection of thiophenol in real samples.
2.7. Imaging in Living Cells
The cytotoxicity of DAPH-DNP was investigated by the MTT assay (Figure S7). The results displayed that DAPH-DNP showed little cytotoxicity for cells. To further investigate the potential utility of DAPH-DNP, the experiments of imaging thiophenol in living cells were carried out. As shown in Figure 6, when HeLa cells were incubated with DAPH-DNP for 0.5 h, washing with PBS showed no fluorescence. However, the HeLa cells, which were preloaded with DAPH-DNP, washed with PBS, and incubated with thiophenol for 0.5 h, showed remarkable red fluorescence. These results suggested that DAPH-DNP can be used for imaging thiophenol in living cells.
Figure 6.

Imaging of DAPH-DNP in HeLa cells. Bright-field (A) and fluorescence images (B) of the cells after the addition of 10 μM DAPH-DNP for 30 min. Bright-field (C) and fluorescence images (D) of the cells incubated with DAPH-DNP for 30 min and then incubated with 80 μM PhSH for another 30 min.
3. Conclusions
In summary, we have synthesized a new NIR fluorescent probe DAPH-DNP for detecting thiophenol via the ESIPT mechanism. The probe exhibited high selectivity and sensitivity, rapid response, remarkable large Stokes shift, and NIR fluorescence recognition for thiophenol. In practical applications, the probe can detect thiophenol in water samples with good recoveries. Importantly, the probe is successfully applied to image thiophenol in living cells. Taken together, the probe is promising for the detection of thiophenol in environmental and biological systems.
4. Experimental Section
4.1. Materials and Instruments
2-Hydroxyacetophenone, cinnamaldehyde, and 1-fluoro-2,4-dinitrobenzene were obtained from Energy Chemical, China. All the other chemical reagents were commercially available. 1H NMR and 13C NMR spectra were recorded on a Bruker AVB-500 spectrometer. HRMS analysis was performed on an Agilent 6530 Accurate-Mass Q-TOF system. Fluorescence spectra were recorded on a F-7000 fluorescence spectrometer at room temperature. UV–vis absorption spectra were recorded with a UV-2600 spectrophotometer. The Eclipse Ti-S inverted fluorescence microscope was applied for fluorescence imaging.
4.2. Preparation of DAPH-DNP
The DAPH compound was synthesized according to the reported literature.58DAPH (0.293 mg, 1 mmol), 1-fluoro-2,4-dinitrobenzene (0.223 mg, 1.2 mmol), and K2CO3 (0.166 mg, 1.2 mmol) were dissolved in DMF (5 mL). The mixture was stirred overnight at room temperature (RT), poured into water (10 mL), and extracted with EtOAc (2 × 50 mL). The organic phase was evaporated and purified by silica column chromatography product DAPH-DNP as a purplish red solid (0.349g, 76%) (Scheme 2). 1H NMR (500 MHz, CDCl3) δ (ppm): 8.80 (s, 1H), 8.24 (d, 1H, J = 8.5 Hz), 7.77 (d, 1H, J = 8.0 Hz), 7.61 (t, 1H, J = 7.0 Hz, J = 14.5 Hz), 7.45 (t, 1H, J = 7.0 Hz, J = 14.5 Hz), 7.36-7.32 (m, 3H), 7.19 (d, 1H, J = 8.5 Hz), 6.87 (d, 2H, J = 8.5 Hz), 6.74 (d, 1H, J = 14.5 Hz), 6.68 (d, 1H, J = 14.5 Hz), 6.64 (d, 2H, J = 8.5 Hz), 3.00 (s, 6H); 13C NMR (125 MHz, CDCl3) δ (ppm): 190.3, 156.4, 151.3, 150.8, 148.2, 144.6, 141.3, 138.7, 133.4, 133.1, 131.1, 129.3, 128.9, 127.1, 125.2, 123.8, 122.1, 121.8, 118.1, 111.9, 40.1, 29.7; HRMS calcd for C25H21N3O6 [M + Na]+ 482.1430, found 482.1321.
Scheme 2. Synthesis of DAPH-DNP.
4.3. Spectroscopic Measurements
The probe DAPH-DNP stock solution was prepared (1.0 × 10–3 mol/L) in DMF. The above stock solutions were used testing solutions was diluted, and then incubated an appropriate volume of 50 mM PBS buffered solution and a certain amount PhSH. The testing solutions was measured by fluorescence spectra.
4.4. Thiophenol Detection in Real Samples
The crud water samples (Yuanjiang River and tap water in Changde city) were passed through a microfiltration membrane before the test. The water samples containing probe DAPH-DNP (10 μM) and thiophenols (0, 5, 10, and 20 μM) were measured used fluorescent spectra.
4.5. Cell Imaging
The HeLa cells were seeded in a 96-well plate and allowed to attach to the culture medium at 37 °C for 24 h. Then, the cells interacted with probe DAPH-DNP (10 μM) for 0.5 h. After washing with PBS, the cells were pretreated with thiophenol and further incubated for 0.5 h at 37 °C. The HeLa cells were washed with PBS and imaged. As control experiments, the HeLa cells were incubated with probe DAPH-DNP (10 μM), washed with PBS, and imaged.
Acknowledgments
We thank the Scientific Research Fund of the Hunan Provincial Education Department (18B369), the National Natural Science Foundation of China (21907026), and the Natural Science Foundation of Hunan Provincial (2019JJ50009) for financial support.
Supporting Information Available
The Supporting Information is available free of charge at https://pubs.acs.org/doi/10.1021/acsomega.0c00389.
Spectroscopic data and NMR and MS spectra (PDF)
The authors declare no competing financial interest.
Supplementary Material
References
- Shimada K.; Mitamura K. Derivatization of thiol-containing compounds. J. Chromatogr. B 1994, 659, 227–241. 10.1016/0378-4347(93)E0444-U. [DOI] [PubMed] [Google Scholar]
- Munday R. Toxicity of thiols and disulphides: involvement of free-radical species. Free Radical Biol. Med. 1989, 7, 659–673. 10.1016/0891-5849(89)90147-0. [DOI] [PubMed] [Google Scholar]
- Eychmüller A.; Rogach A. L. Chemistry and photophysics of thiol-stabilized II-VI semiconductor nanocrystals. Pure Appl. Chem. 2000, 72, 179–188. 10.1351/pac200072010179. [DOI] [Google Scholar]
- Hell T. P.; Lindsay R. C. Toxicological properties of thio-phenols and alkylphenols causing flavor tainting in fish from the upper Wisconsin River. J. Environ. Sci. Health, Part B 1989, 24, 349–360. 10.1080/03601238909372654. [DOI] [PubMed] [Google Scholar]
- Schafer E. W. The acute oral toxicity of 369 pesticidal, pharmaceutical and other chemicals to wild birds. Toxicol. Appl. Pharmacol. 1972, 21, 315–330. 10.1016/0041-008X(72)90151-2. [DOI] [PubMed] [Google Scholar]
- Fairchild E. J.; Stokinger H. E. Acute toxicity of some aliphatic and aromatic thiols (mercaptans). Am. Ind. Hyg. Assoc. J. 1958, 19, 171–189. 10.1080/00028895809343573. [DOI] [PubMed] [Google Scholar]
- Juneja T. R.; Gupta R. L.; Samanta S. Activation of monocrotaline, fulvine and their derivatives to toxic pyrroles by some thiols. Toxicol. Lett. 1984, 21, 185–189. 10.1016/0378-4274(84)90204-2. [DOI] [PubMed] [Google Scholar]
- Amrolia P.; Sullivan S. G.; Stern A.; Munday R. Toxicity of aromatic thiols in the human red blood cell. J. Appl. Toxicol. 1989, 9, 113–118. 10.1002/jat.2550090208. [DOI] [PubMed] [Google Scholar]
- Love J. C.; Estroff L. A.; Kriebel J. K.; Nuzzo R. G.; Whitesides G. M. Self-assembled monolayers of thiolates on metals as a form of nanotechnology. Chem. Rev. 2005, 105, 1103–1170. 10.1021/cr0300789. [DOI] [PubMed] [Google Scholar]
- He J. X.; Akao T.; Tani T. Development of a simple HPLC method for determination of paeoniflorin-metabolizing activity of intestinal bacteria in rat feces. Chem. Pharm. Bull. 2002, 50, 1233–1237. 10.1248/cpb.50.1233. [DOI] [PubMed] [Google Scholar]
- Wang T.; Chamberlain E.; Shi H.; Adams C.; Ma Y. Identification of hydrolytic metabolites of dyfonate in alkaline aqueous solutions by using high performance liquid chromatography-UV detection and gas chromatography-mass spectrometry. Int. J. Environ. Anal. Chem. 2010, 90, 948–961. 10.1080/03067310902874889. [DOI] [Google Scholar]
- Pluchery O.; Humbert C.; Valamanesh M.; Lacaze E.; Busson B. Enhanced detection of thiophenol adsorbed on gold nanoparticles by SFG and DFG nonlinear optical spectroscopy. Phys. Chem. Chem. Phys. 2009, 11, 7729–7737. 10.1039/b902142f. [DOI] [PubMed] [Google Scholar]
- Chan J.; Dodani S. C.; Chang C. J. Reaction-based small-molecule fluorescent probes for chemoselective bioimaging. Nat. Chem. 2012, 4, 973–984. 10.1038/nchem.1500. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Yuan L.; Lin W. Y.; Zheng K. B.; He L. W.; Huang W. M. Far-red to near infrared analyte-responsive fluorescent probes based on organic fluorophore platforms for fluorescence imaging. Chem. Soc. Rev. 2013, 42, 622–661. 10.1039/C2CS35313J. [DOI] [PubMed] [Google Scholar]
- Li X.; Gao X.; Shi W.; Ma H. Design strategies for water-soluble small molecular chromogenic and fluorogenic probe. Chem. Rev. 2014, 114, 590–659. 10.1021/cr300508p. [DOI] [PubMed] [Google Scholar]
- Guo Z. Q.; Park S.; Yoon J. Y.; Shin I. Recent progress in the development of near-infrared fluorescent probes for bioimaging applications. Chem. Soc. Rev. 2014, 43, 16–29. 10.1039/C3CS60271K. [DOI] [PubMed] [Google Scholar]
- Tang Y. H.; Lee D. Y.; Wang J. L.; Li G. H.; Yu J. H.; Lin W. Y.; Yoon J. Y. Development of fluorescent probes based on protection–deprotection of the key functional groups for biological imaging. Chem. Soc. Rev. 2015, 44, 5003–5013. 10.1039/C5CS00103J. [DOI] [PubMed] [Google Scholar]
- Cheng D.; Pan Y.; Wang L.; Zeng Z.; Yuan L.; Zhang X.; Chang Y. T. Selective visualization of the endogenous peroxynitrite in an inflamed mouse model by a mitochondria-targetable two-photon ratiometric fluorescent probe. J. Am. Chem. Soc. 2017, 139, 285–292. 10.1021/jacs.6b10508. [DOI] [PubMed] [Google Scholar]
- Long L. L.; Huang M. Y.; Wang N.; Wu Y. J.; Wang K.; Gong A. H.; Zhang Z. J.; Sessler J. L. A mitochondria-specific fluorescent probe for visualizing endogenous hydrogen cyanide fluctuations in neurons. J. Am. Chem. Soc. 2018, 140, 1870–1875. 10.1021/jacs.7b12545. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Jiao X. Y.; Li Y.; Niu J. Y.; Xie X. L.; Wang X.; Tang B. Small-molecule fluorescent probes for imaging and detection of reactive oxygen, nitrogen, and sulfur species in biological systems. Anal. Chem. 2018, 90, 533–555. 10.1021/acs.analchem.7b04234. [DOI] [PubMed] [Google Scholar]
- Jiang W.; Fu Q. Q.; Fan H.; Y. Ho J.; Wang W. A highly selective fluorescent probe for thiophenols. Angew. Chem. 2007, 119, 8597–8600. 10.1002/ange.200702271. [DOI] [PubMed] [Google Scholar]
- Wang Z.; Han D. M.; Jia W. P.; Zhou Q. Z.; Deng W. P. Reaction-based fluorescent probe for selective discrimination of thiophenols over aliphaticthiols and its application in water samples. Anal. Chem. 2012, 84, 4915–4920. 10.1021/ac300512b. [DOI] [PubMed] [Google Scholar]
- Kand D.; Mishra P.; Saha T.; Lahiri M.; Talukdar P. BODIPY based colorimetric fluorescent probe for selective thiophenol detection: Theoretical and experimental studies. Analyst 2012, 13, 3921–3924. 10.1039/c2an35524h. [DOI] [PubMed] [Google Scholar]
- Zhao C.; Wang X.; Cao J.; Feng P.; Zhang J.; Zhang Y.; Yang Y.; Yang Z. BODIPY-based sulfoxide: Synthesis, photophysical characterization and response to benzenethiols. Dyes Pigm. 2013, 96, 328–332. 10.1016/j.dyepig.2012.08.026. [DOI] [Google Scholar]
- Shiraishi Y.; Yamamoto K.; Sumiya S.; Hirai T. Selective fluorometric detection of aromatic thiols by a chemosensor containing two electrophilic sites with different local softness. Chem. Commun. 2013, 49, 11680–11682. 10.1039/c3cc47220e. [DOI] [PubMed] [Google Scholar]
- Li J.; Zhang C.; Yang S.; Yang W.; Yang G. A. Coumarin-based fluorescent probe for selective and sensitive detection of thiophenols and its application. Anal. Chem. 2014, 86, 3037–3042. 10.1021/ac403885n. [DOI] [PubMed] [Google Scholar]
- Kand D.; Mandal P. S.; Datar A.; Talukdar P. Iminocoumarin based fluorophores: Indispensable scaffolds for rapid, selective and sensitive detection of thiophenol. Dyes Pigm. 2014, 106, 25–31. 10.1016/j.dyepig.2014.02.001. [DOI] [Google Scholar]
- Shao X.; Kang R.; Zhang Y.; Huang Z.; Peng F.; Zhang J.; Wang Y.; Pan F.; Zhang W.; Zhao W. Highly selective and sensitive 1-amino BODIPY-based red fluorescent probe for thiophenols with high off-to-on contrast ratio. Anal. Chem. 2015, 87, 399–405. 10.1021/ac5028947. [DOI] [PubMed] [Google Scholar]
- Lee H.; Kim D. I.; Kwon H.; Kim H. J. Bromoacetylfluorescein monoaldehyde as a fluorescence turn-on probe for cysteine over homocysteine and glutathione. Sens. Actuators, B 2015, 209, 652–657. 10.1016/j.snb.2014.12.042. [DOI] [Google Scholar]
- Li K. B.; Zhou D.; He X. P.; Chen G. R. Ratiometric glycoprobe for transient determination of thiophenol in full aqueous solution and river water. Dyes Pigm. 2015, 116, 52–57. 10.1016/j.dyepig.2015.01.013. [DOI] [Google Scholar]
- Zhang W.; Liu X.; Zhang H.; Feng C.; Liu C.; Yu M.; Wei L.; Li Z. Fluorescent probe for benzenethiols and its application on test paper, in water samples and living cells. J. Mater. Chem. C 2015, 3, 8248–8254. 10.1039/C5TC01363A. [DOI] [Google Scholar]
- Yue Y.; Huo F.; Zhang Y.; Chao J.; Martínez-Máñez R.; Yin C. Curcumin-based “Enhanced SNAr” promoted ultrafast fluorescent probe for thiophenols detection in aqueous solution and in living cells. Anal. Chem. 2016, 88, 10499–10503. 10.1021/acs.analchem.6b02520. [DOI] [PubMed] [Google Scholar]
- Ma Q.; Xu J.; Zhang X.; Zhou L.; Liu H.; Zhang J. A naphthalene-based two-photon fluorescent probe for selective and sensitive detection of thiophenols. Sens. Actuators. B 2016, 229, 434–440. 10.1016/j.snb.2016.02.005. [DOI] [Google Scholar]
- Shang H.; Chen H.; Tang Y.; Ma Y.; Lin W. Development of a two-photon fluorescent turn-on probe with far-red emission for thiophenols and its bioimaging application in living tissues. Biosens. Bioelectron. 2017, 95, 81–86. 10.1016/j.bios.2017.04.017. [DOI] [PubMed] [Google Scholar]
- Chen S.; Li H.; Hou P. A large stokes shift fluorescent probe for sensing of thiophenols based on imidazo[1,5-α]pyridine in both aqueous medium and living cells. Anal. Chim. Acta 2017, 993, 63–70. 10.1016/j.aca.2017.09.016. [DOI] [PubMed] [Google Scholar]
- Ren T. B.; Xu W.; Zhang W.; Zhang X. X.; Wang Z. Y.; Xiang Z.; Yuan L.; Zhang X. B. A general method to increase stokes shift by introducing alternating vibronic structures. J. Am. Chem. Soc. 2018, 140, 7716–7722. 10.1021/jacs.8b04404. [DOI] [PubMed] [Google Scholar]
- Ren T. B.; Zhang Q. L.; Su D.; Zhang X. X.; Yuan L.; Zhang X. B. Detection of analytes in mitochondria without interference from other sites based on an innovative ratiometric fluorophore. Chem. Sci. 2018, 9, 5461–5466. 10.1039/C8SC01673A. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wang H.; Wu X. M.; Yang S. X.; Tian H. Y.; Liu Y. G.; Sun B. G. A rapid and visible colorimetric fluorescent probe for benzenethiol flavor detection. Food Chem. 2019, 286, 322–328. 10.1016/j.foodchem.2019.02.033. [DOI] [PubMed] [Google Scholar]
- Liu H.; Guo C. L.; Guo S. J.; Fan J. T.; Wang L. J.; Shi D. Y. Chalcone-analogue fluorescent probes for detecting thiophenols in seawater sample. Talanta 2019, 201, 301–308. 10.1016/j.talanta.2019.03.112. [DOI] [PubMed] [Google Scholar]
- Lv W. J.; Chen Y. L.; Bian L.; Chen X. G. A new double-emission fluorescent probe for fast detection of thiophenols in aqueous solution and living cells. Talanta 2019, 197, 204–210. 10.1016/j.talanta.2019.01.022. [DOI] [PubMed] [Google Scholar]
- Sun X. F.; Kong C. P.; Zhang H. X. Sensing mechanism of a fluorescent probe for thiophenols: Invalidity of excited-state intramolecular proton transfer mechanism. Spectrochim. Acta, Part A 2020, 231, 118129 10.1016/j.saa.2020.118129. [DOI] [PubMed] [Google Scholar]
- Yang L. L.; Li Y. P.; Song H. X.; Zhang H. H.; Yang N.; Peng Q.; Ji L. G.; He G. J. A highly sensitive probe based on spiropyran for colorimetric and fluorescent detection of thiophenol in aqueous media. Dyes Pigm. 2020, 175, 108154 10.1016/j.dyepig.2019.108154. [DOI] [Google Scholar]
- Feng Y.; Cao C.; Ru J. X.; Yang Y. Y.; Wang Z.; Song X. R.; Wang K.; Zhang G. L.; Liu W. S. An ultrasensitive and visible lighting-up probe for imaging thiophenols in water samples, in serum and visualizing thiophenols-induced oxidative stress process in live cells. Talanta 2020, 210, 120622 10.1016/j.talanta.2019.120622. [DOI] [PubMed] [Google Scholar]
- Guo Z.; Park S.; Yoon J.; Shin I. Recent progress in the development of near-infrared fluorescent probes for bioimaging applications. Chem. Soc. Rev. 2014, 43, 16–29. 10.1039/C3CS60271K. [DOI] [PubMed] [Google Scholar]
- Hameed S.; Dai Z. Near-infrared fluorescence probes for surgical navigation. Mater. today Chem. 2018, 10, 90–103. 10.1016/j.mtchem.2018.07.005. [DOI] [Google Scholar]
- Wu D.; Chen L.; Lee W.; Ko G.; Yin J.; Yoon J. Recent progress in the development of organic dye based near-infrared fluorescence probes for metal ions. Coord. Chem. Rev. 2018, 354, 74–97. 10.1016/j.ccr.2017.06.011. [DOI] [Google Scholar]
- Zhang Y.; Wang J. H.; Zheng W.; Chen T.; Tong Q. X.; Li D. An ESIPT fluorescent dye based on HBI with high quantum yield and large Stokes shift for selective detection of Cys. J. Mater. Chem. B 2014, 2, 4159–4166. 10.1039/C4TB00190G. [DOI] [PubMed] [Google Scholar]
- Yang L.; Su Y. N.; Sha Z. K.; Geng Y. N.; Qi F. P.; Song X. Z. A red-emitting fluorescent probe for hydrogen sulfide in living cells with a large Stokes. Org. Biomol. Chem. 2018, 16, 1150–1156. 10.1039/C7OB02641B. [DOI] [PubMed] [Google Scholar]
- Geng Y.; Tian H.; Yang L.; Liu X.; Song X. An aqueous methylated chromenoquinoline-based fluorescent probe for instantaneous sensing of thiophenol with a red emission and a large Stokes shift. Sens. Actuators, B 2018, 273, 1670–1675. 10.1016/j.snb.2018.07.088. [DOI] [Google Scholar]
- Zhang D. X.; Xu N.; Li H. D.; Yao Q. C.; Xu F.; Fan J. L.; Du J. J.; Peng X. X. Probing thiophenol pollutant in solutions and cells with BODIPY-based fluorescent probe. Ind. Eng. Chem. Res. 2017, 56, 9303–9309. 10.1021/acs.iecr.7b02557. [DOI] [Google Scholar]
- Li Z. L.; Liu C. Y.; Chen Y.; Yuan R. F.; Jia P.; Wang Z. K.; Duan Q. X.; Zhu H. C.; Zhu B. C.; Sheng W. L. A water-soluble and highly specific fluorescent probe for imaging thiophenols in living cells and zebrafish. New J. Chem. 2019, 43, 6746–6752. 10.1039/C9NJ00324J. [DOI] [Google Scholar]
- Khandare D. G.; Banerjee M.; Gupta R.; Kumar N.; Ganguly A.; Singh D.; Chatterjee A. Green synthesis of a benzothiazole based ‘turn-on’ type fluorimetric probe and its use for the selective detection of thiophenols in environmental samples and living cells. RSC Adv. 2016, 6, 52790–52797. 10.1039/C6RA07046A. [DOI] [Google Scholar]
- Zhou S.; Rong Y.; Wang H.; Liu X.; Wei L.; Song X. A naphthalimide-indole fused chromophore-based fluorescent probe for instantaneous detection of thiophenol with a red emission and a large Stokes shift. Sens. Actuators, B 2018, 276, 136–141. 10.1016/j.snb.2018.08.096. [DOI] [Google Scholar]
- Liu H.; Guo C.; Guo S.; Fan J.; Wang L.; Shi D. Chalcone-analogue fluorescent probes for detecting thiophenols in seawater samples. Talanta 2019, 201, 301–308. 10.1016/j.talanta.2019.03.112. [DOI] [PubMed] [Google Scholar]
- Chen W.; Yue X.; Li W.; Hao Y.; Song X.; et al. A phenothiazine coumarin-based red emitting fluorescent probe for nanomolar detection of thiophenol with a large Stokes shift. Sens. Actuators, B 2017, 245, 702–710. 10.1016/j.snb.2017.01.167. [DOI] [Google Scholar]
- Liu X. J.; Qi F. P.; Su Y. N.; Chen W. Q.; Yang L.; Song X. Z. A red emitting fluorescence probe for instantaneous sensing of thiophenol in both aqueous medium and living cells with a large Stokes shift. J. Mater. Chem. C 2016, 4, 4320–4326. 10.1039/C5TC03977K. [DOI] [Google Scholar]
- Ren R.; Xu H.-C.; Dong H.; Peng H.-T.; Wu P.-P.; Qiu Y.; Yang S.-G.; Sun Q.; She N.-F. Ultrafast 2,7-Naphthyridine-Based fluorescent probe for detection of thiophenol with a remarkable Stokes shift and its application in vitro and in vivo. Talanta 2019, 205, 120067 10.1016/j.talanta.2019.06.067. [DOI] [PubMed] [Google Scholar]
- Han C. Y.; Song B.; Liang X.; Pan H.; Dong W. Design and application of a fluorescent probe based on ESIPT mechanism for the detection of Cys with o-hydroxyacetophenone structure. Anal. Methods 2019, 11, 2513–2517. 10.1039/C9AY00708C. [DOI] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.




