Skip to main content
Endoscopy International Open logoLink to Endoscopy International Open
. 2020 May 25;8(6):E775–E782. doi: 10.1055/a-1136-9971

Expert endoscopists with high adenoma detection rates frequently detect diminutive adenomas in proximal colon

Osamu Toyoshima 1,2, Toshihiro Nishizawa 1,3, Shuntaro Yoshida 1,2, Kazuma Sekiba 1,2, Yosuke Kataoka 1,4, Keisuke Hata 1,5, Hidenobu Watanabe 6, Yosuke Tsuji 2, Kazuhiko Koike 2
PMCID: PMC7247898  PMID: 32490163

Abstract

Background and study aims  Adenoma detection rate (ADR) is an important quality indicator in colonoscopy, and improved ADR decreases the incidence of colorectal cancer. We investigated differences in polyp detection according to the endoscopist’s ADR.

Patients and methods  We performed a propensity-score matching study using baseline patient characteristics of age, sex, body mass index, family history of colorectal cancer, smoking, drinking, indication for colonoscopy, bowel preparation, and colonoscope type. We compared polyp detection and colonoscopy procedures between patients who underwent colonoscopy by high-ADR endoscopists (high ADR group) and by low-ADR endoscopists (low ADR group).

Results  We matched 334 patients in the high ADR group with 334 in the low ADR group. The ADR was 44.0 % and 26.9 % for the high-ADR and low-ADR endoscopists, respectively. Proximal, nonprotruding, and diminutive adenomas were more frequently detected by high-ADR endoscopists than by low-ADR endoscopists (all P  < 0.001); similarly, more high-risk adenomas were detected by high-ADR endoscopists ( P  = 0.028). Furthermore, more sessile serrated polyps detected by high-ADR endoscopists ( P  = 0.041). High-ADR endoscopists more frequently performed pancolonic chromoendoscopy ( P  < 0.001).

Conclusions  Expert detectors often found nonprotruding and diminutive adenomas in the proximal colon along with increased detection rate of high-risk adenomas. Low-ADR endoscopists need to recognize the features of missed adenomas to improve their ADRs.

Introduction

Colorectal cancer (CRC) is the third most commonly diagnosed cancer (1.8 million cases, 10.2 % of the total cancers). CRC is responsible for the second largest number of deaths (881,000 deaths, 9.2 %) 1 . Colonoscopy has been associated with a reduced incidence of CRC. Screening colonoscopy has been associated with reduced CRC mortality 2 . Screening for CRC has resulted in a significant reduction in CRC incidence through the detection and removal of adenomatous polyps and other precancerous lesions, and incidence reduction and early detection of CRC has in turn resulted in a reduction in CRC mortality 3 . The adenoma detection rate (ADR) is an important quality indicator of colonoscopy and is inversely associated with the risks of interval CRC, advanced-stage interval cancer, and fatal interval cancer 4 5 . Increased ADR has been reported to be associated with a reduced risk of interval CRC and death 6 . Therefore, it is essential to know the type of adenomas that are missed by endoscopists with low ADR. However, it remains unclear.

We investigated the differences in detected polyps and colonoscopy procedures between patients who underwent colonoscopy by endoscopists with either a high or low ADR.

Patients and methods

Ethics

This retrospective study was approved by the Ethical Review Committee of the Hattori Clinic on September 6, 2019 (approval no. S1909-U06). Written informed consent was obtained from the participants. All clinical investigations were conducted according to the ethical guidelines of the Declaration of Helsinki.

Study population

This propensity-score matching study comprised subjects who agreed to participate in the study and underwent colonoscopy by board-certificated endoscopists at the Toyoshima Endoscopy Clinic, an outpatient clinic specializing in endoscopy, between April and November 2017. Colonoscopy was performed to evaluate symptoms (i. e., bleeding including positive results of fecal occult blood test, abdominal symptoms, and abnormal bowel habits), for screening, or for polyp surveillance. We excluded patients who were not willing to undergo removal of colorectal polyps, patients who had previously been diagnosed with CRC and/or inflammatory bowel disease, and/or had undergone colorectal surgery except appendectomy, and patients who had indications for treatment including colorectal polypectomy and hemostasis. We excluded colonoscopy procedures that did not reach the cecum due to bowel stenosis, procedures with poor bowel preparation precluding complete observation, and procedures that did not remove all the polyps due to the large size and/or number of polyps 7 8 9 . We removed polyps numbering 10 or less, those with a diameter of 15 mm or less, and those with a cumulative diameter of 30 mm or less, at a single colonoscopy procedure. Details on baseline characteristics, polyp detection, and colonoscopy procedures were obtained through review of patient medical records.

Diagnosis of polyps

To endoscopically diagnose colorectal polyps, we used the updated Paris Endoscopic Classification of superficial neoplastic lesions in the digestive tract 10 . We primarily diagnosed a polyp as a sessile serrated polyp (SSP) according to the following findings: proximal location; flat, elevated, or sessile; irregular shape; indistinctive border; cloud-like surface; mucus cap; normal or pale color; none or dilated vessels, and/or dilated crypts 11 . Polyp size was measured by placing a closed snare or forceps, which has a thickness of 2 mm, against the lesion. Lesions diagnosed as adenomas or SSPs were removed either by hot or cold polypectomy using a snare or forceps or by endoscopic mucosal resection on the examination day.

All resected specimens were examined histologically under hematoxylin and eosin staining. One experienced gastrointestinal pathologist (H.W.) diagnosed the polyps, including adenomas and SSPs, according to the World Health Organization criteria 12 . Traditional serrated adenomas were included in the adenoma category, but SSPs were not. An advanced adenoma was defined as an adenoma with a villous component, with a size larger than 10 mm, or with high-grade dysplasia based on the World Health Organization definition 12 . Low-risk adenomas were defined as one or two tubular adenomas less than 10 mm and high-risk adenomas were defined as at least one advanced adenoma or three or more adenomas 13 . Only lesions that were histologically confirmed as adenomas or SSPs were counted 14 .

Colonoscopy equipment

Patients underwent colonoscopy with an Elite CF290 endoscopy system (CV-290 and CLV-290, Olympus, Japan) with a 290 series colonoscope (CF-HQ290Z, CF-HQ290, or PCF-H290Z, Olympus, Japan) or a 260 series colonoscope (PCF-PQ260 or CF-H260) and a carbon dioxide (CO 2 ) insufflator (UCR CO 2 regulation unit, Olympus, Japan). NBI was available for all the scopes. A flushing pump (OFP-2, Olympus, Japan) was used for the 290 series colonoscope. PCF-H290Z and PCF-PQ260 were used for patients aged 80 years or older, patients aged 70 years or older who had undergone a previous abdominal surgery, and patients likely to experience a difficult insertion due to a colon adhesion found during a previous colonoscopy 9 . We used an image filing system (T-File System; STS Medic, Japan).

Colonoscopy procedure

Small shaking, jiggling, and right turn shortening maneuvers have been frequently used for colonoscope insertion 9 . Extra gas and liquid were aspirated and removed as much as possible. For colonic insufflation, CO 2 was administered through the UCR for patients without chronic respiratory failure. Colonoscopies were performed under conscious sedation with midazolam (0.5 to 10 mg) and/or pethidine hydrochloride (17.5 to 70 mg) according to the patient’s willingness. In the absence of contraindications, we administered 10 to 20 mg of scopolamine butylbromide or 0.5 to 1 mg glucagon (genetic recombinant).

The observation time for withdrawal of the colonoscope was standardized as at least 6 minutes 15 . Pancolonic chromoendoscopy (PCC) was performed at the discretion of each endoscopist. PCC involved pancolonic spraying with 0.05 % indigo carmine using a 20-mL syringe placed directly through the colonoscope accessory channel. We repeated the administration of 5 mL indigo carmine with 10 mL air-spraying 10 to 20 times during the withdrawal procedure, and the pools of excess dye were suctioned before the examination. The colonoscope was sequentially withdrawn as the prescribed position changed 16 17 : the ascending colon/hepatic flexure was examined in the left lateral decubitus position; the transverse colon was examined in the supine position; the splenic flexure, descending colon, and sigmoid-descending colon junction were examined in the right lateral position; and the sigmoid colon and rectum were examined in the right lateral position.

Patients involved in this study underwent colonic preparation with 2 L of polyethylene glycol solution administered orally 5 hours before the procedure. Polyethylene glycol solution or magnesium citrate was added when the stool was not in the clear liquid form. The quality of bowel preparation was graded as A (all colon segments empty and clean or minor amount of fluid in the gut that was easily removed by suction), B (at least one colon segment with residual amounts of brown liquid or semi-solid stool that could be easily removed or displaced), C (at least one colon segment with only partially removable stool preventing complete visualization of mucosa), or D (at least one colon segment that could not be examined due to the presence of remaining solid stool). The following colon segments were rated: rectum, sigmoid colon, descending colon, transverse colon, and ascending colon/cecum 18 . Patients identified with grade D bowel preparation during the colonoscopy were excluded.

Statistical analysis

We calculated average ADR of all enrolled procedures and ADRs for each endoscopist, during the study period. An endoscopist having an ADR higher than the average ADR was defined as a high-ADR endoscopist, and an endoscopist having an ADR lower than the average ADR was defined as a low-ADR endoscopist 19 20 21 . We divided the patients into those underwent colonoscopy by a high-ADR endoscopist (the high-ADR group) and those who underwent colonoscopy by a low-ADR endoscopist (the low-ADR group).

Baseline patient characteristics were age, sex, body mass index, past malignancy except CRC, first-degree relative with a history of CRC, smoking (Brinkman score ≥ 400), drinking (≥ 1 cup of alcohol per day), indication for colonoscopy (evaluation of symptoms, screening, or polyp surveillance), bowel preparation grade (A, B, or C), and the type of colonoscope (290 series or 260 series) . These characteristics were clinically important and reported to be associated with colon polyp detection 7 9 15 18 22 23 24 25 26 .

To reduce the effects of selection bias and potential confounding factors in this study, we performed rigorous adjustments for significant differences in all the baseline characteristics of patients by using propensity-score matching 27 28 . Patients who underwent colonoscopy by high-ADR endoscopists were identified and propensity-score matched with those who underwent colonoscopy by low-ADR endoscopists. Matching was performed with a 1:1 matching protocol using nearest-neighbor matching without replacement and with a caliper width of 0.946, which was one standard deviation of logarithm odds for patients who underwent colonoscopy by low-ADR endoscopists ( Table 1 ) 29 30 31 .

Table 1. Baseline characteristics of patients before and after propensity-score matching.

Before matching After matching
Low-ADR group High-ADR group Low-ADR group High-ADR group P value
No. of patients 418 599 334 334
Age 1 , years 49.9 (11.6)  53.8 (13.2)  50.2 (11.9)  50.1 (12.1) 0.91
Sex, female 213 334 171 170 0.94
Body mass index 1 , kg/m 2  22.1 (3.0)  22 (3.1)  22.1 (2.9)  22.0 (3.0) 0.82
Past malignancy except CRC, %   7.9   7.9   7.8   6.6 0.55
Family history of CRC, %  14.6  14.5  14.1  13.5 0.82
Smoking, %  11.7   9.7  10.8  10.2 0.80
Drinking, %  28.0  22.7  25.7  24.3 0.66
Indication for colonoscopy
  • Evaluation of symptoms

109 145  85  87
  • Screening

174 309 152 152 0.90
  • Polyp surveillance

135 145  97  95 0.83
Bowel preparation grade 2
  • A

244 278 181 176
  • B

146 241 125 132 0.61
  • C

 28  80  28  26 0.87
Colonoscope type
  • 260 series

110  25  26  24
  • 290 series

308 574 308 310 0.77

The caliper width was set to 0.946 (one standard deviation of logarithm odds for the patients who underwent colonoscopy by low-ADR endoscopists). P values were calculated by the Wald test using logistic regression.

ADR, adenoma detection rate; CRC, colorectal cancer.

1

Mean (standard deviation).

2

Bowel preparation: A, all colon segments empty and clean or minor amount of fluid in the gut, but easily removed by suction; B, at least one colon segment with residual amounts of brown liquid or semi-solid stool that could be easily removed or displaced; C, at least one colon segment with only partially removable stool preventing complete visualization of mucosa.

Following the propensity-score matching, we compared the polyp detection rates, numbers of polyps per procedure, and the colonoscopy procedures between the two groups. The polyp detection rates included ADRs, advanced ADRs, low-risk ADRs, high-risk ADRs, SSP detection rates, and adenoma plus SSP detection rates. The numbers of polyps included the total number of adenomas, number of adenomas by location, number of adenomas by morphology, number of adenomas by size, number of SSPs, and number of adenomas plus SSPs. The colonoscopy procedures included insertion time, withdrawal time including the time required for polypectomy, and whether PCC was performed. We assessed P values by using the Wald test with logistic regression.

Statistical significance was considered a two-sided P  < 0.05. All statistical analyses were performed using R version 3.5.1(R Core Team 2018, R Foundation for Statistical Computing, Vienna, Austria)

Results

Study population

We identified 1017 individuals who met our inclusion criteria ( Fig. 1 ). These patients underwent colonoscopy by 13 endoscopists. The average ADR of the endoscopists during this period was 37.0 %. We defined 11 physicians as low-ADR (26.1 %, range 18.2 %–35.1 %) endoscopists and two physicians as high-ADR (44.6 %, range 37.6 %–45.3 %) endoscopists. Of the 1017 patients, we divided 418 into low-ADR group and 599 into high-ADR group. Prior to propensity-score matching, there were differences between the two groups in the baseline patient characteristics of age, bowel preparation, and the colonoscope used ( Table 1 ). Using propensity-score matching, 334 patients in the high-ADR group were matched with 334 patients in the low-ADR group. After matching, there was no longer any significant difference between the two groups with respect to any of the baseline characteristics.

Fig. 1 .

Fig. 1 

Flowchart of patient enrollment and propensity-score matching. ADR, adenoma detection rate.

Outcomes for the matched patients

A comparison of outcomes between the matched patients in the low-ADR group and the high-ADR group is shown in Table 2 . The ADR was 44.0 % and 26.9 % for the high-ADR and low-ADR endoscopists, respectively. The number of adenomas detected in the high-ADR group was higher than that in the lower-ADR group. The number of adenomas per positive procedure of the high-ADR group was higher than that of the low-ADR group. The number of adenomas identified in the proximal colon, type 0-II adenomas, and adenomas ≤ 5 mm was larger in the high-ADR group than that in the low-ADR group (all P  < 0.001). The number of adenomas detected in the distal colon and rectum, type 0-I adenomas, and adenomas ≥ 6 mm was similar between both the groups. Advanced ADR was similar for both the groups; however, the high-risk ADR in the high-ADR group was higher than that in the low-ADR group ( P  = 0.028). The number of SSPs in the high-ADR group was larger than that in the low-ADR group ( P  = 0.041). Insertion time and withdrawal time in the high-ADR group were shorter than that in the low-ADR group. PCC was more frequently performed in the high-ADR group than in the low-ADR group ( P  < 0.001).

Table 2. Comparison of outcomes in patients who underwent colonoscopy by low-ADR endoscopists and patients who underwent colonoscopy by high-ADR endoscopists after propensity-score matching.

Low-ADR group High-ADR group P value
N = 334 N = 334
Adenoma detection rate (95 % CI) 26.9 % (22.2–31.7) 44.0 % (38.7–49.3) < 0.001
No. of adenomas 1 0.374 (0.719) 0.751 (1.069) < 0.001
No. of adenomas 2 1.389 (0.714) 1.707 (1.069) 0.0080
No. of adenomas by location 1
  • Proximal colon

0.180 (0.456) 0.533 (0.902) < 0.001
    • Cecum

0.033 (0.179) 0.078 (0.290) 0.016
    • Ascending colon

0.087 (0.303) 0.204 (0.537) < 0.001
    • Transverse colon

0.060 (0.250) 0.251 (0.567) < 0.001
  • Distal colon

0.156 (0.424) 0.192 (0.501) 0.32
    • Descending colon

0.045 (0.221) 0.030 (0.171) 0.33
    • Sigmoid colon

0.111 (0.333) 0.162 (0.456) 0.10
  • Rectum

0.039 (0.194) 0.027 (0.162) 0.39
    • Rs

0.027 (0.162) 0.012 (0.109) 0.16
    • Ra

0.006 (0.077) 0.003 (0.055) 0.56
    • Rb

0.006 (0.077) 0.012 (0.109) 0.41
No. of adenomas by morphology 1
  • Type 0-I

0.087 (0.322) 0.081 (0.314) 0.81
    • 0-Ip

0.006 (0.077) 0.003 (0.055) 0.56
    • 0-Is

0.081 (0.314) 0.078 (0.310) 0.90
  • Type 0-II

0.287 (0.611) 0.671 (0.998) < 0.001
    • 0-IIa

0.287 (0.611) 0.659 (0.988) < 0.001
    • 0-IIc

0.000 (0.000) 0.012 (0.109) 0.045
No. of adenomas by size 1
  •  ≤ 5 mm

0.293 (0.598) 0.683 (1.011) < 0.001
    • 1–3 mm

0.222 (0.513) 0.512 (0.823) < 0.001
    • 4–5 mm

0.072 (0.281) 0.171 (0.436) < 0.001
  • 6–9 mm

0.060 (0.250) 0.057 (0.245) 0.88
  •  ≥ 10 mm

0.021 (0.143) 0.012 (0.109) 0.36
Advanced adenoma detection rate 2.10 % 1.20 % 0.37
Low-risk adenoma detection rate 23.7 % 36.8 % < 0.001
High-risk adenoma detection rate 3.29 % 7.19 % 0.028
SSP detection rate 7.49 % 10.5 % 0.18
No. of SSPs 1 0.081 (0.284) 0.141 (0.453) 0.041
Adenoma + SSP detection rate 32.6 % 49.4 % < 0.001
No. of adenomas + SSPs 1 0.455 (0.761) 0.892 (1.178) < 0.001
Procedure
  • Insertion time 3 , minutes

5.683 (2.873) 4.117 (2.030) < 0.001
  • Withdrawal time 3 , minutes

14.243 (5.407) 12.964 (2.850) < 0.001
  • Pancolonic chromoendoscopy

88.6 % 98.2 % < 0.001

P values were calculated by the Wald test using logistic regression.

ADR, adenoma detection rate; CI, confidence interval; SSP, sessile serrated polyp.

1

Mean per procedure (standard deviation).

2

Mean per positive procedure (standard deviation).

3

Mean (standard deviation).

Discussion

ADR is associated with the incidence and mortality of CRC, and an improvement in the ADR also reduces the incidence of CRC and its mortality 3 4 5 6 . In the present study, low-ADR endoscopists missed more proximal, nonprotruding, and/or diminutive adenomas. Some studies showed that patients who developed interval CRC are more likely to have proximal cancer than those with distal cancer 32 33 . There are some possible reasons for the distribution of interval CRC. One hypothesis is that some physicians may more often miss adenomas in the proximal colon than in the distal colon 34 . Lieberman et al. 13 described that failure to fully examine the proximal colon, quality of bowel preparation, variable equipment of colonoscopy, and the endoscopist’s skill could lead to overlooking of the adenomas. Another possible reason is the biological differences between neoplastic lesions in the proximal and the distal colon, such as the sessile serrated lesions 35 . Interval cancers are more likely located in the proximal colon, have microsatellite instability, and have CpG island methylator phenotype. The mismatch repair defects correlated to microsatellite instability may induce a rapid accumulation of mutations and accelerated cancer development 36 37 . Rondagh et al. 38 have reported that proximal adenomas with high-grade dysplasia/early CRC were more likely to be diminutive or nonpolypoid than the distal ones. Low-ADR endoscopists should be aware of the features of these missed adenomas and improve their ADRs.

Expert detectors more frequently diagnosed not only adenomas but also high-risk adenomas than the low-ADR endoscopists did. Guidelines for colonoscopy surveillance after screening and polypectomy issued by the United States Multi-Society Task Force on CRC recommend that patients without an adenoma undergo surveillance at 10 years, those with low-risk adenomas undergo surveillance at 5 to 10 years, and those with high-risk adenomas undergo surveillance at 3 years 13 . If a patient undergoes colonoscopy by a low-ADR endoscopist, not only do adenomas with the potential for cancerization remain, but the surveillance interval also becomes longer, which increases the patient’s chances of developing CRC. It might be better to adjust the surveillance colonoscopy interval taking into account the individual ADR of the baseline endoscopist.

In this study, advanced ADR was similar for both the groups. Greenspan et al. 39 reported that advanced ADR was variable among colonoscopists with acceptable ADRs and that colonoscopists’ advanced ADRs were independent of their nonadvanced ADRs. Their results support our findings. Lee et al. 40 described that measuring total adenoma detection (mean number of adenomas per procedure and mean number of adenomas per positive procedure) as adjuncts to ADR may further enhance quality assurance. Our study revealed that the mean number of adenomas per positive procedure of the high-ADR group was significantly higher than that of the low-ADR group, and withdrawal time in the high-ADR group was shorter than that in the low-ADR group. The high-ADR endoscopists in this study efficiently detected and removed adenomas.

High-ADR endoscopists more frequently conducted PCC than the low-ADR endoscopists did. We have previously reported that PCC using the new-generation endoscopy system could detect proximal colon adenomas in addition to white-light observation and NBI observation 24 . Low-ADR endoscopists should consider applying PCC as one of the methods to raise their ADRs.

There are some possible limitations of our study. This study was a retrospective propensity-score matching comparison. Propensity-score matching might have resulted in some biases. The present study was conducted in a single center. The calculated number of colonoscopies per one endoscopist is small. This appears slightly suboptimal for the formal calculations of ADR and other parameters. ADR now is mainly referred for colonoscopies performed for CRC screening; however, our examination involved indication for symptom evaluation and for polyp surveillance. Patients with residual polyps that could not be removed in our clinic were excluded from the analysis. Withdrawal time included time taken for maneuvers such as polypectomy that were performed during the withdrawal phase. It was difficult to subtract polyp removal time from withdrawal time due to the retrospective study design. Interobserver variability in polyp size could have resulted in some bias. We defined an endoscopist with an ADR lower than the average ADR in this study as a low-ADR endoscopist. Consequently, the mean ADR of low-ADR endoscopists was 26.1 % which was more than 25 % of the recommendation for benchmark ADR 41 . In the future, investigation based on the benchmark ADR is desirable. The bowel preparation scale of this study was not a gold standard. We should have used Boston Bowel Preparation Scale or Aronchick Scale, which are international standards 42 . Studies should be planned to address these aspects and corroborate our findings.

Conclusion

In conclusion, expert detectors often found proximal, nonprotruding, and diminutive colorectal polyps and demonstrated an increased high-risk ADR.

Acknowledgements

The authors thank StaGen Co., Ltd. for statistical analyses and Editage for English editing.

Footnotes

Competing interests The authors declare that they have no conflict of interest.

References

  • 1.Ferlay J, Colombet M, Soerjomataram I et al. Estimating the global cancer incidence and mortality in 2018: GLOBOCAN sources and methods. Int J Cancer. 2019;144:1941–1953. doi: 10.1002/ijc.31937. [DOI] [PubMed] [Google Scholar]
  • 2.Wolf A MD, Fontham E TH, Church T R et al. Colorectal cancer screening for average-risk adults: 2018 guideline update from the American Cancer Society. CA Cancer J Clin. 2018;68:250–281. doi: 10.3322/caac.21457. [DOI] [PubMed] [Google Scholar]
  • 3.Nishihara R, Wu K, Lochhead P et al. Long-term colorectal-cancer incidence and mortality after lower endoscopy. N Engl J Med. 2013;369:1095–1105. doi: 10.1056/NEJMoa1301969. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Kaminski M F, Regula J, Kraszewska E et al. Quality indicators for colonoscopy and the risk of interval cancer. N Engl J Med. 2010;362:1795–1803. doi: 10.1056/NEJMoa0907667. [DOI] [PubMed] [Google Scholar]
  • 5.Corley D A, Jensen C D, Marks A R et al. Adenoma detection rate and risk of colorectal cancer and death. N Engl J Med. 2014;370:1298–1306. doi: 10.1056/NEJMoa1309086. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Kaminski M F, Wieszczy P, Rupinski M et al. Increased rate of adenoma detection associates with reduced risk of colorectal cancer and death. Gastroenterology. 2017;153:98–105. doi: 10.1053/j.gastro.2017.04.006. [DOI] [PubMed] [Google Scholar]
  • 7.Kahi C J, Anderson J C, Waxman I et al. High-definition chromocolonoscopy vs. high-definition white light colonoscopy for average-risk colorectal cancer screening. Am J Gastroenterol. 2010;105:1301–1307. doi: 10.1038/ajg.2010.51. [DOI] [PubMed] [Google Scholar]
  • 8.Lai E J, Calderwood A H, Doros G et al. The Boston bowel preparation scale: a valid and reliable instrument for colonoscopy-oriented research. Gastrointest Endosc. 2009;69:620–625. doi: 10.1016/j.gie.2008.05.057. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Toyoshima O, Yoshida S, Nishizawa T et al. CF290 for pancolonic chromoendoscopy improved sessile serrated polyp detection and procedure time: a propensity score-matching study. Endosc Int Open. 2019;7:E987–E993. doi: 10.1055/a-0953-1909. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Endoscopic Classification Review Group . Update on the paris classification of superficial neoplastic lesions in the digestive tract. Endoscopy. 2005;37:570–578. doi: 10.1055/s-2005-861352. [DOI] [PubMed] [Google Scholar]
  • 11.Kashida H. Endoscopic diagnosis of sessile serrated polyp: A systematic review. Dig Endosc. 2019;31:16–23. doi: 10.1111/den.13263. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Bosman F T, Carneiro F, Hruban R H . Lyon: International Agency for Research on Cancer; 2010. WHO classification of tumours of the digestive system. Fourth edition. [Google Scholar]
  • 13.Lieberman D A, Rex D K, Winawer S J et al. Guidelines for colonoscopy surveillance after screening and polypectomy: a consensus update by the US Multi-Society Task Force on Colorectal Cancer. Gastroenterology. 2012;143:844–857. doi: 10.1053/j.gastro.2012.06.001. [DOI] [PubMed] [Google Scholar]
  • 14.Lee T J, Rees C J, Blanks R G et al. Colonoscopic factors associated with adenoma detection in a national colorectal cancer screening program. Endoscopy. 2014;46:203–211. doi: 10.1055/s-0033-1358831. [DOI] [PubMed] [Google Scholar]
  • 15.Barclay R L, Vicari J J, Doughty A S. Colonoscopic withdrawal times and adenoma detection during screening colonoscopy. N Engl J Med. 2006;355:2533–2541. doi: 10.1056/NEJMoa055498. [DOI] [PubMed] [Google Scholar]
  • 16.East J E, Suzuki N, Arebi N et al. Position changes improve visibility during colonoscope withdrawal: a randomized, blinded, crossover trial. Gastrointest Endosc. 2007;65:263–269. doi: 10.1016/j.gie.2006.04.039. [DOI] [PubMed] [Google Scholar]
  • 17.Ou G, Kim E, Lakzadeh P et al. A randomized controlled trial assessing the effect of prescribed patient position changes during colonoscope withdrawal on adenoma detection. Gastrointest Endosc. 2014;80:277–283. doi: 10.1016/j.gie.2014.01.032. [DOI] [PubMed] [Google Scholar]
  • 18.Ell C, Fischbach W, Bronisch H J et al. Randomized trial of low-volume PEG solution versus standard PEG + electrolytes for bowel cleansing before colonoscopy. Am J Gastroenterol. 2008;103:883–893. doi: 10.1111/j.1572-0241.2007.01708.x. [DOI] [PubMed] [Google Scholar]
  • 19.Lee R H, Tang R S, Muthusamy V R et al. Quality of colonoscopy withdrawal technique and variability in adenoma detection rates (with videos) Gastrointest Endosc. 2011;74:128–134. doi: 10.1016/j.gie.2011.03.003. [DOI] [PubMed] [Google Scholar]
  • 20.Sastre Lozano VM, Moran Sanchez S, Garcia Solano J et al. Relationship between the polyp detection rate and the post-colonoscopy colorectal cancer rate. Rev Esp Enferm Dig. 2019;111:598–602. doi: 10.17235/reed.2019.5889/2018. [DOI] [PubMed] [Google Scholar]
  • 21.Gurudu S R, Boroff E S, Crowell M D et al. Impact of feedback on adenoma detection rates: Outcomes of quality improvement program. J Gastroenterol Hepatol. 2018;33:645–649. doi: 10.1111/jgh.13984. [DOI] [PubMed] [Google Scholar]
  • 22.Leung W K, Lo O S, Liu K S et al. Detection of colorectal adenoma by narrow band imaging (HQ190) vs. high-definition white light colonoscopy: a randomized controlled trial. Am J Gastroenterol. 2014;109:855–863. doi: 10.1038/ajg.2014.83. [DOI] [PubMed] [Google Scholar]
  • 23.Gerard D P, Foster D B, Raiser M W et al. Validation of a new bowel preparation scale for measuring colon cleansing for colonoscopy: the chicago bowel preparation scale. Clin Transl Gastroenterol. 2013;4:e43. doi: 10.1038/ctg.2013.16. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Toyoshima O, Hata K, Yoshida S et al. New-generation chromoendoscopy may increase confidence in the DISCARD2 study. Gut. 2018;67:1742–1743. doi: 10.1136/gutjnl-2017-314999. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Anderson J C, Butterly L F, Weiss J E et al. Providing data for serrated polyp detection rate benchmarks: an analysis of the New Hampshire Colonoscopy Registry. Gastrointest Endosc. 2017;85:1188–1194. doi: 10.1016/j.gie.2017.01.020. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Hata K, Shinozaki M, Toyoshima O et al. Impact of family history of gastric cancer on colorectal neoplasias in young Japanese. Colorectal Dis. 2013;15:42–46. doi: 10.1111/j.1463-1318.2012.03108.x. [DOI] [PubMed] [Google Scholar]
  • 27.Rosenbaum P R, Rubin D B. The central role of the propensity score in observational studies for causal effects. Biometrika. 1983;70:41–55. [Google Scholar]
  • 28.D'Agostino R B., Jr Propensity score methods for bias reduction in the comparison of a treatment to a non-randomized control group. Stat Med. 1998;17:2265–2281. doi: 10.1002/(sici)1097-0258(19981015)17:19<2265::aid-sim918>3.0.co;2-b. [DOI] [PubMed] [Google Scholar]
  • 29.Normand S T, Landrum M B, Guadagnoli E et al. Validating recommendations for coronary angiography following acute myocardial infarction in the elderly: a matched analysis using propensity scores. J Clin Epidemiol. 2001;54:387–398. doi: 10.1016/s0895-4356(00)00321-8. [DOI] [PubMed] [Google Scholar]
  • 30.Austin P C. Optimal caliper widths for propensity-score matching when estimating differences in means and differences in proportions in observational studies. Pharm Stat. 2011;10:150–161. doi: 10.1002/pst.433. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31.Bangalore S, Guo Y, Samadashvili Z et al. Everolimus-eluting stents or bypass surgery for multivessel coronary disease. N Engl J Med. 2015;372:1213–1222. doi: 10.1056/NEJMoa1412168. [DOI] [PubMed] [Google Scholar]
  • 32.Bressler B, Paszat L F, Chen Z et al. Rates of new or missed colorectal cancers after colonoscopy and their risk factors: a population-based analysis. Gastroenterology. 2007;132:96–102. doi: 10.1053/j.gastro.2006.10.027. [DOI] [PubMed] [Google Scholar]
  • 33.Brenner H, Chang-Claude J, Seiler C M et al. Protection from colorectal cancer after colonoscopy: a population-based, case-control study. Ann Intern Med. 2011;154:22–30. doi: 10.7326/0003-4819-154-1-201101040-00004. [DOI] [PubMed] [Google Scholar]
  • 34.Pohl H, Robertson D J. Colorectal cancers detected after colonoscopy frequently result from missed lesions. Clin Gastroenterol Hepatol. 2010;8:858–864. doi: 10.1016/j.cgh.2010.06.028. [DOI] [PubMed] [Google Scholar]
  • 35.Leggett B, Whitehall V. Role of the serrated pathway in colorectal cancer pathogenesis. Gastroenterology. 2010;138:2088–2100. doi: 10.1053/j.gastro.2009.12.066. [DOI] [PubMed] [Google Scholar]
  • 36.Arain M A, Sawhney M, Sheikh S et al. CIMP status of interval colon cancers: another piece to the puzzle. Am J Gastroenterol. 2010;105:1189–1195. doi: 10.1038/ajg.2009.699. [DOI] [PubMed] [Google Scholar]
  • 37.Sawhney M S, Farrar W D, Gudiseva S et al. Microsatellite instability in interval colon cancers. Gastroenterology. 2006;131:1700–1705. doi: 10.1053/j.gastro.2006.10.022. [DOI] [PubMed] [Google Scholar]
  • 38.Rondagh E J, Bouwens M W, Riedl R G et al. Endoscopic appearance of proximal colorectal neoplasms and potential implications for colonoscopy in cancer prevention. Gastrointest Endosc. 2012;75:1218–1225. doi: 10.1016/j.gie.2012.02.010. [DOI] [PubMed] [Google Scholar]
  • 39.Greenspan M, Rajan K B, Baig A et al. Advanced adenoma detection rate is independent of nonadvanced adenoma detection rate. Am J Gastroenterol. 2013;108:1286–1292. doi: 10.1038/ajg.2013.149. [DOI] [PubMed] [Google Scholar]
  • 40.Lee T J, Rutter M D, Blanks R G et al. Colonoscopy quality measures: experience from the NHS Bowel Cancer Screening Programme. Gut. 2012;61:1050–1057. doi: 10.1136/gutjnl-2011-300651. [DOI] [PubMed] [Google Scholar]
  • 41.Hilsden R J, Rose S M, Dube C et al. Defining and applying locally relevant benchmarks for the adenoma detection rate. Am J Gastroenterol. 2019;114:1315–1321. doi: 10.14309/ajg.0000000000000120. [DOI] [PubMed] [Google Scholar]
  • 42.Kastenberg D, Bertiger G, Brogadir S. Bowel preparation quality scales for colonoscopy. World J Gastroenterol. 2018;24:2833–2843. doi: 10.3748/wjg.v24.i26.2833. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Endoscopy International Open are provided here courtesy of Thieme Medical Publishers

RESOURCES