Abstract
Regular atrial tachycardia (AT) is one of the most important proarrhythmic complications that may occur following left atrial pulmonary vein isolation (PVI). These tachycardias that develop after atrial fibrillation ablation may lead to worse symptoms than those from the original arrhythmia existing prior to the index ablation procedure. Ablation of various types of supraventricular tachycardias without the use of fluoroscopy has been shown to be feasible in both children and adults using three-dimensional mapping systems. We describe the case of a 71-year-old woman who developed a focal AT after a successful PVI procedure. The initial ablation failed with one mapping system. Repeat electrophysiologic study despite antiarrhythmic medications revealed the same focal AT, which was successfully ablated with a different mapping system. Both ablations were performed without fluoroscopy.
Keywords: Atrial fibrillation, atrial tachycardia, catheter ablation, electroanatomic mapping, zero radiation
Introduction
Regular atrial tachycardia (AT) or atrial flutter is one of the most important proarrhythmic complications that can occur following left atrial (LA) pulmonary vein isolation (PVI).1 The reported incidence of late ATs ranges from between 1% and 2.9% to between 10% and 24%.2,3 More extensive LA ablation, especially mitral lines and roof lines, are associated with a higher incidence of AT.4 Additionally, persistent atrial fibrillation (AF), increased LA size, and fibrosis may lead to increased AT development. Regular or organized ATs may occur weeks to months after the initial ablation.5 These tachycardias that develop after AF ablation may result in worse symptoms than those associated with the original arrhythmia prior to the index ablation procedure. Frequently, post-PVI ATs are often incessant and associated with rapid ventricular response.6,7 The mechanism of the AT is usually one of the following: focal, microreentrant, or macroreentrant.8 Frequently, conservative therapies, including antiarrhythmic medications, are not effective. Radiofrequency ablation procedures are mostly successful, but can be challenging, and require a complex approach.9
Ablation of various types of supraventricular and ventricular tachycardias without the use of fluoroscopy has been shown to be feasible in both children and adults, especially pregnant women, using nonfluoroscopic three-dimensional mapping systems (ie, zero-fluoroscopy approach). Also, it is feasible to use complex procedures such as PVI to treat AF without the use of fluoroscopy or protective lead aprons.10 Despite recent advances in electroanatomic mapping systems, the majority of cardiac electrophysiologists still rely on fluoroscopic techniques.11 There is no amount of radiation exposure that is known to be completely safe.12 Over time, both the stochastic and deterministic effects of radiation may lead to life-threatening cancers; therefore, the use of ionizing radiation should be as low as reasonably achievable (ALARA).13 Finally, a whole host of orthopedic issues may develop from the long-term use of protective lead aprons.14
Case presentation
After unsuccessful treatment with antiarrhythmic medications, a 71-year-old female was referred for treatment of drug-refractory, symptomatic, paroxysmal AF. She underwent an uncomplicated zero-fluoroscopy PVI procedure using a previously described technique without linear lesions.10 After confirming exit block of the pulmonary veins, she developed an intermittent regular, narrow-complex, mid- to long-RP tachycardia (Figure 1A) with a cycle length of 470 ms. The earliest activation in coronary sinus (CS) 7–8 was easily inducible with rapid atrial pacing (Figure 1B). We were unable to entrain successfully, as the tachycardia would terminate. Based on these findings, we felt that this was most consistent with an AT. Using the CARTO® 3 system (Biosense Webster, Diamond Bar, CA, USA) and mapping with the PentaRay® multipolar catheter (Biosense Webster, Diamond Bar, CA, USA), the earliest activation appeared to originate outside of the right superior pulmonary vein (RSPV). The tachycardia appeared to terminate after a number of ablations at the ostium of the RSPV. The tachycardia was again reinitiated with atrial pacing (Figure 2A) with a similar cycle length and CS activation pattern. At this point, we mapped the right atrium (RA) and the earliest points were found to originate from the superoposterior portion of the RA near the superior vena cava junction (Figure 2B). The distal ablation point was measured 10 ms early and the tachycardia ultimately terminated, though a number of ablation attempts were required (Figure 2B).
Unfortunately, the patient reported continued daily palpitations at four weeks after the procedure despite the use of medical therapy including ß-blockers, calcium channel blockers, and flecainide. Holter monitoring revealed what appeared to be the same AT with a similar cycle length. Repeat electrophysiologic study was performed with the EnSite Precision™ cardiac mapping system (Abbott Laboratories, Chicago, IL, USA), again without fluoroscopy. An alternative mapping system was used to obtain a higher-definition map with a greater number and concentration of points. AT was induced easily and, again, the superoposterior RA was affected earliest, with the same CS activation pattern and cycle length as noted previously. LA mapping with the Advisor™ FL Circular Mapping Catheter, Sensor Enabled™ (Abbott Laboratories, Chicago, IL, USA) revealed exit block in all four pulmonary veins without electrical activity. The entire cycle length was obtained with windows set from −97 ms to −99 ms. RA mapping was completed with a fill threshold of 20 units, with more than 7,500 points obtained in less than five minutes (Figure 3A). Both the previous ablation site and the origin were easily located. A propagation map using local activation time clearly identified the “pebble in the pond” that seemed consistent with a focal AT (Video 1). Utilization of the SparkleMap feature allowed for further visualization of the focality of this rhythm (Video 2). Ablation at a site 20 ms early and adjacent to the prior ablation terminated the tachycardia with one burn (Figure 3B) at 15 seconds (Figure 3C). The tachycardia was no longer inducible with burst pacing, even in the presence of isoproterenol. The patient was discharged the following day without complications. She has not had a recurrence in the six months off flecainide to date and is maintained solely on low-dose ß-blocker therapy for hypertension.
Discussion
This case demonstrates a number of pertinent points. First, post-PVI AT is common and can be very symptomatic for patients. Additionally, ATs may be more difficult to treat/cure than the original paroxysmal AF for which the index ablation procedure was performed. The origin of the AT may not be in the original chamber first identified, as was true in this case wherein the AT originated from the RA and not the RSPV. The proximity of the RSPV and the RA including interatrial connections are well described. Furthermore, there are differences among the different mapping systems: while some use magnetic data solely (eg, CARTO® from Biosense Webster, Diamond Bar, CA, USA), others use both magnetic and impedance data for mapping (eg, EnSite Precision™ from Abbott Laboratories, Chicago, IL, USA) and are reported to have up to 27 times greater capability in point acquisition density.15 To add to this, both types of systems can deliver propagation maps with local activation time. However, only the latter (ie, EnSite Precision™ from Abbott Laboratories, Chicago, IL, USA) has the SparkleMap feature that allows the operator to view live peak-to-peak voltage activation. More recently, however, CARTO® (Biosense Webster, Diamond Bar, CA, USA) has added the Ripple Mapping feature, which has similar capabilities. Finally and most importantly, the complex ablation of post-PVI AT, including even redo procedures using two different mapping systems, may be completed safely without using harmful radiation. All electrophysiologists performing ablations with fluoroscopic radiation should meticulously scrutinize fluoroless techniques in order to reduce the amount of ionizing radiation to themselves, their patients, and staff and to eliminate mechanical disorders from long-term use of protective lead aprons.
Conclusion
Complex ablation of post-PVI AT may be performed safely using a zero-fluoroscopy approach with multiple high-density mapping systems, which may improve outcomes in redo ablation cases.
Acknowledgements
Special thanks to Timothy Wayne Allison of Abbott Laboratories and Heidi Helmer of Biosense Webster.
References
- 1.Sághy L, Tutuianu C, Szilágyi J. Atrial tachycardias following atrial fibrillation ablation. Curr Cardiol Rev. 2015;11(2):149–156. doi: 10.2174/1573403X10666141013122400. [CrossRef] [PubMed] [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Oral H, Knight BP, Tada H, et al. Pulmonary vein isolation for paroxysmal and persistent atrial fibrillation. Circulation. 2002;105(9):1077–1081. doi: 10.1161/hc0902.104712. [CrossRef] [PubMed] [DOI] [PubMed] [Google Scholar]
- 3.Oral H, Knight BP, Morady F. Left atrial flutter after segmental ostial radiofrequency catheter ablation for pulmonary vein isolation. Pacing Clin Electrophysiol. 2003;26(6):1417–1419. doi: 10.1046/j.1460-9592.2003.t01-1-00202.x. [CrossRef] [PubMed] [DOI] [PubMed] [Google Scholar]
- 4.Gerstenfeld EP, Callans DJ, Dixit S, et al. Mechanisms of organized left atrial tachycardias occurring after pulmonary vein isolation. Circulation. 2004;110(11):1351–1357. doi: 10.1161/01.CIR.0000141369.50476.D3. [CrossRef] [PubMed] [DOI] [PubMed] [Google Scholar]
- 5.Chugh A, Oral H, Lemola K, et al. Prevalence, mechanisms, and clinical significance of macroreentrant atrial tachycardia during and following left atrial ablation for atrial fibrillation. Heart Rhythm. 2005;2(5):464–471. doi: 10.1016/j.hrthm.2005.01.027. [CrossRef] [PubMed] [DOI] [PubMed] [Google Scholar]
- 6.Deisenhofer I, Estner H, Zrenner B, et al. Left atrial tachycardia after circumferential pulmonary vein ablation for atrial fibrillation: incidence, electrophysiological characteristics, and results of radiofrequency ablation. Europace. 2006;8(8):573–582. doi: 10.1093/europace/eul077. [CrossRef] [PubMed] [DOI] [PubMed] [Google Scholar]
- 7.Sawhney N, Anousheh R, Chen W, et al. Circumferential pulmonary vein ablation with additional linear ablation results in an increased incidence of left atrial flutter compared with segmental pulmonary vein isolation as an initial approach to ablation of paroxysmal atrial fibrillation. Circ Arrhythm Electrophysiol. 2010;3:243–248. doi: 10.1161/CIRCEP.109.924878. [DOI] [PubMed] [Google Scholar]
- 8.Rostock T, Drewitz I, Steven D, et al. Characterization, mapping, and catheter ablation of recurrent atrial tachycardias after stepwise ablation of long-lasting persistent atrial fibrillation. Circ Arrhythm Electrophysiol. 2010;3(2):160–169. doi: 10.1161/CIRCEP.109.899021. [CrossRef] [PubMed] [DOI] [PubMed] [Google Scholar]
- 9.Chae S, Oral H, Good E, et al. Atrial tachycardia after circumferential pulmonary vein ablation of atrial fibrillation mechanistic insights, results of catheter ablation, and risk factors for recurrence. J Am Coll Cardiol. 2007;50(18):1781–1787. doi: 10.1016/j.jacc.2007.07.044. [CrossRef] [PubMed] [DOI] [PubMed] [Google Scholar]
- 10.Percell J, Sharpe E, Percell R. SANS FLUORO (SAy No Series to FLUOROscopy): a first-year experience. J Innov Cardiac Rhythm Manage. 2016;7(11):2529–2534. doi: 10.19102/icrm.2016.071102. [DOI] [Google Scholar]
- 11.Macías R, Uribe I, Tercedor L, Jiménez-Jáimez J, Barrio T, Álvarez M. A zero-fluoroscopy approach to cavotricuspid isthmus catheter ablation: comparative analysis of two electroanatomical mapping systems. Pacing Clin Electrophysiol. 2014;37(8):1029–1037. doi: 10.1111/pace.12376. [CrossRef] [PubMed] [DOI] [PubMed] [Google Scholar]
- 12.Gaita F, Guerra PG, Battaglia A, Anselmino M. The dream of near-zero X-rays ablation comes true. Eur Heart J. 2016;37(36):2749–2755. doi: 10.1093/eurheartj/ehw223. [CrossRef] [PubMed] [DOI] [PubMed] [Google Scholar]
- 13.Casella M, Ribatti V, Catto V, et al. Benefits of electroanatomic ablation of conventional cardiac arrhythmias: from fluoroscopy to zero X-ray mapping. Minerva Cardioangiol. 2018;66(1):49–62. doi: 10.23736/S0026-4725.17.04478-4. [CrossRef] [PubMed] [DOI] [PubMed] [Google Scholar]
- 14.Ernst S, Castellano I. Radiation exposure and safety for the electrophysiologist. Curr Cardiol Rep. 2013;15(10):402–407. doi: 10.1007/s11886-013-0402-2. [CrossRef] [PubMed] [DOI] [PubMed] [Google Scholar]
- 15.Heist EK, Perna F, Chaloub F, et al. Comparison of electroanatomical mapping systems: accuracy in left atrial mapping. Pacing Clin Electrophysiol. 2013;36(5):626–631. doi: 10.1111/pace.12095. [CrossRef] [PubMed] [DOI] [PubMed] [Google Scholar]