Utility of Xpert Ultra on Different Respiratory Specimens in Children

Saurav Jain 1, Prawin Kumar 1,*, Jagdish Prasad Goyal 1
PMCID: PMC7258649  PMID: 32176533

To the Editor:

We read with great interest the recent article on the yield of Xpert Ultra on different respiratory samples in children by Zar and colleagues (1). We must congratulate the authors for conducting such a novel study that will definitively increase the horizon of diagnosis of tuberculosis (TB) in children. However, there are some crucial points in this article that need clarification and further consideration.

The main objective of this study was to investigate diagnostic accuracy and yield of Xpert Ultra on repeated induced sputum (IS), nasopharyngeal aspirates (NPAs), or a combination of IS and NPAs. Although Ultra was performed on repeated (two) NPA specimens, it was performed on only one IS specimen, despite the fact that two IS specimens were collected. The author’s previous study had shown that Xpert Ultra had good sensitivity and specificity (77% and 97%, respectively) on IS (2). Furthermore, in this study, the authors have also concluded that IS provides higher yields than NPAs and that it is a preferable sample for Ultra. Therefore, the inclusion of Xpert Ultra on second IS specimens also might have further increased its sensitivity and specificity.

The semiquantitative results of Xpert Ultra were mainly trace or very low; however, these results were only on NPA specimens. It would be worthwhile to know such results on IS specimens in comparison with NPA specimens.

According to the result of this study, Xpert Ultra was positive on 20 first NPA (17 in confirmed TB and 3 in unconfirmed TB) specimens. In this way, the positive predictive value should be 17/20 (85%); however, in Table 3 of Reference 1, it was mentioned as 156/175 (89.1%). It commences confusion among readers, which needs rectification.

The result of this study gives the impression that Xpert Ultra is more sensitive than Xpert MTB/RIF (74.3% vs. 68.6%, respectively). However, Xpert MTB/RIF was performed only in 165 IS specimens in comparison with Xpert Ultra, which was performed on 195 IS specimens. Therefore, the yield of Xpert Ultra does not seem to be better than the Xpert MTB/RIF, at least on IS specimens.

Supplementary Material

Supplements
Author disclosures

Footnotes

Author Contributions: P.K. and J.P.G. conceptualized the material and critical review of the article. S.J. prepared the initial draft. All the authors contributed to the finalization of manuscript and agreed to submission for publication. P.K. will act as guarantor for this letter.

Originally Published in Press as DOI: 10.1164/rccm.202002-0377LE on March 16, 2020

Author disclosures are available with the text of this letter at www.atsjournals.org.

References

  • 1.Zar HJ, Workman LJ, Prins M, Bateman LJ, Mbhele SP, Whitman CB, et al. Tuberculosis diagnosis in children using Xpert Ultra on different respiratory specimens. Am J Respir Crit Care Med. 2019;200:1531–1538. doi: 10.1164/rccm.201904-0772OC. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Nicol MP, Workman L, Prins M, Bateman L, Ghebrekristos Y, Mbhele S, et al. Accuracy of Xpert Mtb/Rif Ultra for the diagnosis of pulmonary tuberculosis in children. Pediatr Infect Dis J. 2018;37:e261–e263. doi: 10.1097/INF.0000000000001960. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplements
Author disclosures

Articles from American Journal of Respiratory and Critical Care Medicine are provided here courtesy of American Thoracic Society

RESOURCES