Amplicon sequencing of the 16S rRNA gene is commonly used for the identification of bacterial isolates in diagnostic laboratories and mostly relies on the Sanger sequencing method. The latter, however, suffers from a number of limitations, with the most significant being the inability to resolve mixed amplicons when closely related species are coamplified from a mixed culture. This often leads to either increased turnaround time or absence of usable sequence data. Short-read next-generation sequencing (NGS) technologies could solve the mixed amplicon issue but would lack both cost efficiency at low throughput and fast turnaround times.
KEYWORDS: taxonomy, 16S RNA gene, bioinformatics, clinical methods, diagnostics, nanopore, sequencing
ABSTRACT
Amplicon sequencing of the 16S rRNA gene is commonly used for the identification of bacterial isolates in diagnostic laboratories and mostly relies on the Sanger sequencing method. The latter, however, suffers from a number of limitations, with the most significant being the inability to resolve mixed amplicons when closely related species are coamplified from a mixed culture. This often leads to either increased turnaround time or absence of usable sequence data. Short-read next-generation sequencing (NGS) technologies could solve the mixed amplicon issue but would lack both cost efficiency at low throughput and fast turnaround times. Nanopore sequencing developed by Oxford Nanopore Technologies (ONT) could solve those issues by enabling a flexible number of samples per run and an adjustable sequencing time. Here, we report on the development of a standardized laboratory workflow combined with a fully automated analysis pipeline LORCAN (long read consensus analysis), which together provide a sample-to-report solution for amplicon sequencing and taxonomic identification of the resulting consensus sequences. Validation of the approach was conducted on a panel of reference strains and on clinical samples consisting of single or mixed rRNA amplicons associated with various bacterial genera by direct comparison to the corresponding Sanger sequences. Additionally, simulated read and amplicon mixtures were used to assess LORCAN’s behavior when dealing with samples with known cross-contamination levels. We demonstrate that by combining ONT amplicon sequencing results with LORCAN, the accuracy of Sanger sequencing can be closely matched (>99.6% sequence identity) and that mixed samples can be resolved at the single-base resolution level. The presented approach has the potential to significantly improve the flexibility, reliability, and availability of amplicon sequencing in diagnostic settings.
INTRODUCTION
The sequencing of the 16S rRNA gene is essential to describe the diversity of the human microbiome (1, 2). Yet, the frequency of the use of 16S sequencing for species identification from cultured isolates in clinical laboratories is decreasing (3) despite the usefulness of 16S rRNA gene sequencing to provide taxonomic classification for isolates that do not match recognized biochemical profiles, that only produce low identification score according to commercial systems, or that are not typically associated with human pathogens (3, 4). In the clinical microbiology laboratory, amplicon sequencing of the 16S rRNA gene mostly relies on the Sanger sequencing method, which is based on chain termination via fluorescently labeled deoxyribonucleotides (dNTPs), capillary electrophoresis, and fluorescence measurement (5). Although the Sanger method is still the gold standard for validating the accuracy of sequences from specific genes, when compared to more recent technologies, the method has a number of significant shortcomings. During a sequencing run, each capillary is limited to the production of one single sequence with a maximal length of about 1,000 bp (6), resulting in low throughput and high sequencing costs. Furthermore, the sequencing machines are comparably large and require maintenance, limiting their suitability for all types of laboratory settings. The most important limitation of the Sanger method, however, is its limited ability to produce complete sequence information when diverse amplicons are present (7). Under routine diagnostic conditions, this frequently leads to either increased turnaround time or lack of results (8), leading to potential delays or inaccuracies in patient treatment and management.
Next-generation sequencing technologies (i.e., second-generation sequencing technologies, such as those provided by Illumina) might overcome most of these limitations but are not designed for the analysis of small numbers of pure amplicons. Even the smallest and fastest available 500- and 600-cycle Illumina kits show runtimes of >24 h, with associated running costs of several hundred euro regardless of the numbers of samples processed (Illumina, Inc.), limiting their usefulness for the fast and flexible identification of small batches of samples. The third-generation single-molecule sequencing technology provided by Oxford Nanopore Technologies (ONT) might offer the necessary flexibility in throughput and is capable of producing reads with lengths of several hundred to several hundred thousand bases at competitive costs (9). Furthermore, ONT sequencers are small devices, virtually maintenance free, and affordable for small laboratories. Despite the constant improvement over the last years in read accuracy (with read accuracy of about 96% currently), the remaining sequencing errors in single nanopore reads do not yet allow for an analysis at the read level. De novo assembly or consensus generation from individual ONT reads are, therefore, commonly used to generate sequences that are virtually free from substitution errors (10). Additionally, “polishing” tools can be applied to remove remaining nonrandom errors, such as indels in homopolymer regions, from the generated consensus sequences (10–13). Resulting sequences can then be directly substituted to Sanger sequences in existing classification pipelines or, due to the added flexibility in read length, may provide far higher resolution if the analyses are based on full-length marker genes or entire operons (14). One obstacle for a broad adoption of nanopore sequencing in routine diagnostic laboratories is the added bioinformatic complexity compared to established Sanger sequencing workflows. Furthermore, available workflows are often limited to the analysis of pure amplicons (10–13), include complex modifications of the ONT laboratory workflows (15, 16), or lack published validation by using samples other than mock communities (17, 18).
Here, we developed a complete workflow based on standard ONT protocols and a fully automated analysis pipeline LORCAN capable of producing high-quality consensus sequences and thorough taxonomic analysis from pure and low-complexity cultures. The foreseen end users of the workflow are clinical bacteriology laboratories. As such, tunable workflow parameters were evaluated with amplicons generated from reference strains of pathogenic genera (Bacteroides, Eggerthella, Enterococcus, Klebsiella, Mycobacterium, Campylobacter, Pseudomonas) and validated on bacterial cultures obtained from patient material over several months. Furthermore, we explored the robustness of LORCAN’s consensus generation and species identification by analyzing artificial mixtures of amplicons and reads at different levels of genetic distances.
MATERIALS AND METHODS
Samples, DNA extraction, PCR amplification.
Bacterial isolates all originated from the Institute for Infectious Diseases (IFIK, Bern) Biobank. The IFIK provides the entire spectrum of medical microbiological diagnostic services to the largest Swiss hospital group (Inselgruppe) and other regional hospitals. The diagnostic division of IFIK (clinical microbiology) is ISO/IEC 17025 accredited to perform routine bacterial diagnostics from clinical samples. ATCC strains were obtained from LGC Standards (Wesel, Germany) and were grown on solid medium as recommended by the manufacturer.
Bacterial cultures grown overnight were harvested from agar plates and dissolved in 300 μl of Tris-EDTA (pH 8.0). DNA was extracted with a NucliSens easyMag (bioMérieux, Switzerland) robot according to the manufacturer’s protocol. The 16S rRNA gene PCR was performed with the primer sets 16S_f, 5′-AGAGTTTGATCMTGGCTCAG-3′, and 16S_r, 5′-TACCGCGGCWGCTGGCACRDA-3′, (general bacteria) and mbak_f, 5′-GAGTTTGATCCTGGCTCAGGA-3′, and mbak_r, 5′-TGCACACAGGCCACAAGGGA-3′, (mycobacteria) supplemented with the universal tails 5′-TTTCTGTTGGTGCTGATATTGC-3′ (ONT forward primer), 5′-ACTTGCCTGTCGCTCTATCTTC-3′ (ONT reverse primer), 5′-TGTAAAACGACGGCCAG-3′ (M13f, Sanger forward primer), or 5′-CAGGAAACAGCTATGAC-3′ (M13r, Sanger reverse primer). PCR mixtures (25 μl) for general bacteria and mycobacteria were assembled, respectively, with 1 and 2.5 ng DNA template and 10 μl of a 1.25 and 2.5 μM primer working solution, both with 12.5 μl Q5 master mix. Amplification was performed in a GeneAmp 9700 thermocycler (Thermo Fisher Scientific, Inc., MA, USA) with the following program: 98°C for 1 min; 30 cycles of 98°C for 10 s, 63°C for 15 s, 72°C for 30 s; and 72°C for 2 min. PCR products were purified with CleanNGS beads (CleanNA, Waddinxveen, Netherlands) according to the manufacturer’s instructions with the following modifications: after the washing step, an additional 3-s centrifugation step was introduced, and the purified DNA was eluted in 80 μl of Tris-HCl (0.01 M, pH 8.0). Fragment size of the amplicons was analyzed using the TapeStation D1000 assay (Agilent, Santa Clara, CA, USA), concentrations were measured with the Qubit double-stranded DNA (dsDNA) broad-range (BR) assay (Thermo Fisher Scientific), and the purity of the DNA was analyzed with a NanoDrop spectrophotometer (Thermo Fisher Scientific). Samples with DNA concentrations of <1.05 nM were excluded from the analysis.
Library preparation.
A typical library consisted of the pooling of PCR amplicons from 2 to 15 clinical samples and 1 positive control (Mycobacteria intracellulare, amplified with general bacterial primers). Library preparation was performed with the kits EXP-PBC096 and SQL-LSK109 (Oxford Nanopore Technologies, Oxford, UK) using the supplementary reagents NEBNext end repair/dA-tailing module (E7546; New England Biolabs, ON, CA), NEB Blunt/TA ligase master mix (M0367; New England Biolabs), Taq 2× master mix (NEB M0270; New England Biolabs), and CleanNGS beads (CleanNA). All modifications made to the manufacturer’s protocol (PCR barcoding [96] genomic DNA, PBAC96_9069_v109_revK_14Aug2019) are described in the following section (see also Fig. 1A; for a detailed protocol, see Text S1 in the supplemental material). AMPure beads were substituted with CleanNGS beads, and the HulaMixer (Thermo Fisher Scientific) parameters “orbital: 40 rpm, 07 s; reciprocal: 89 deg, 2 s; vibro: 5 deg, 2 s; vertical position” were used. Barcoding PCRs (12 cycles) were set up with 25.2 nmol of template per reaction. Raw barcoded PCR products were quantified with the Qubit dsDNA BR assay and pooled at equal molar proportions. Products containing less than 0.57 pmol DNA were excluded from the analysis. If the total amount of DNA in a pooled library was below 9.23 pmol, “place-holder” (filling) barcoded samples were added to the pooled library to avoid flow cell underloading (see example of calculations and adjustments in Text S1). Place-holder barcoded samples were produced in advance from the same template as the positive controls, with 15 instead of 12 barcoding PCR cycles. Resulting PCR products were quantified with Qubit and stored at −20°C. The pooled library was purified (CleanNGS beads; 50-μl elution volume) and quantified with the Qubit dsDNA BR assay. The purified library pools were diluted to 140 nM before proceeding to the “end preparation” step of the protocol.
Sequencing.
ONT sequencing was performed on a GridION X5 instrument (Oxford Nanopore Technologies) with real-time basecalling enabled (ont-guppy-for-gridion v.1.4.3-1 and v.3.0.3-1; fast basecalling mode). Sequencing runs were terminated after production of 1 million reads or when sequencing rates dropped below 20 reads per second. Purified PCR products were submitted to Sanger sequencing at Microsynth (Balgach, Switzerland).
Bioinformatic analyses.
(i) LORCAN pipeline description. LORCAN was developed to facilitate reproducible ONT sequencing-based marker gene analysis in diagnostics facilities. The pipeline, written in Perl 5, R, and BASH, runs on Linux servers or workstations. The code is publicly available (19) and is based on publicly available, third-party dependencies (see Table S1 in the supplemental material). Major steps of the workflow are described in the following section (numbers correspond to the steps in Fig. 1B). In step 1, basecalled reads are demultiplexed and adapters trimmed (Porechop [20], parameters: –format fasta, –discard_unassigned, –require_two_barcodes). In step 2, reads are filtered by length, keeping only those with lengths of −20 to +100 bases (lower boundary adjustable) around the modal sequence length (custom Perl and R scripts) (Fig. 1B). In step 3, reads are mapped to a nonredundant reference database (minimap2 [21]; see database preparation below). In step 4, reads are extracted, binned by taxonomic level (here species), and remapped to the reference sequence that obtained the highest number of mapped reads among all sequences of the corresponding species (minimap2, SAMtools [22], SeqKit [23]). In step 5, consensus sequences are derived using a 50% majority rule consensus. In step 6, the 10 closest reference sequences are selected by sequence similarity to the consensus sequence (blastn, BLAST+ [24]). In step 7, phylogenetic trees for each consensus sequence with its 10 closest references are created (MAFFT [25] with parameters -maxiterate 1000 –localpair; gBlocks [26] with parameters −t = d; and IQ-Tree [27] with parameters -m GTR+I+G -bb 1000 -czb). Parameters of all software are also provided in the LORCAN GitHub repository.
(ii) Database preparation. Reference databases used by LORCAN are nonredundant and assay specific. Detailed instructions for database creation are provided online (https://github.com/aramette/LORCAN/). In short, the reference database (in this study, leBIBI SSU-rDNA-mk37_stringent, https://umr5558-bibiserv.univ-lyon1.fr/BIBIDOCNEW/db-BIBI.html [28]) was trimmed to the region of interest (amplified region minus primers) and dereplicated (mothur [29]), and sequence names were simplified (custom Perl scripts). The names of identical sequences are saved to a file during the dereplication step. The resulting nonredundant database is then used to generate a custom BLAST database, which is used in LORCAN pipeline.
(iii) Sanger sequence analyses. Forward and reverse sequences were assembled into consensus sequences using SeqMan Pro (DNA Star, Madison, WI, USA), primers were trimmed manually, and ambiguous bases were resolved based on visual inspection of the chromatograms. Consensus sequences were taxonomically classified using the online tool leBIBI QBPP (28, 30).
(iv) SNV discrimination and performance with mixed samples. Amplicons produced from pure samples were quantified (Qubit dsDNA BR assay). Mixtures of pure amplicons were produced at defined ratios before library preparation to produce libraries of heterogeneous (“mixed”) samples. Artificial read mixtures were also produced in silico by mixing reads originating from pure amplicon samples. Those reads were obtained from the LORCAN output directories (output file 1_fasta/BC*.fasta produced by step 2) (Fig. 1B) and sampled using Seqtk subseq (v.1.3-r106) (https://github.com/lh3/seqtk) to produce different proportions of original, pure amplicons. Reads from mixed amplicon samples were fed back into LORCAN, and detected species compositions were extracted from the resulting LORCAN reports. Sequence identities between the paired Mycobacterium species were determined based on pairwise alignment of the amplified region using MultAlin v.5.4.1 (http://multalin.toulouse.inra.fr/multalin/ [31]).
(v) Influence of database completeness on consensus accuracy. Amplicons from a set of seven ATCC reference strains were ONT sequenced and analyzed with LORCAN using the full nonredundant leBIBI 16S rRNA database, restricted to the region amplified by the general bacterial primer set. The resulting top consensus sequences were extracted and combined with the above-mentioned database. The resulting sequence data set was aligned (MAFFT v.7.313, FFT-NS-1, progressive method), and pairwise distances were calculated (mothur v.1.40.5, dist.seqs, calc = eachgap, countends = F, cutoff = 0.20). For each consensus sequence, 10 subsets of sequences with minimal distances below thresholds ranging from 0 to 0.1 were extracted (Seqtk subseq), and minimal distances between each data set and the corresponding consensus sequence were analyzed. The seven ATCC read sets were reanalyzed with LORCAN and the corresponding database subsets to produce consensus sequences. Top consensus sequences from each combination of sample and subsetted database were extracted, combined with the consensus sequences generated with the full database, and aligned (MAFFT v.7.313, L-INS-I, iterative refinement method (<16) with local pairwise alignment information). Pairwise distances were analyzed as described above, and distances between the consensus sequences generated with the full and the subsetted databases were extracted.
Data availability.
All reads and consensus sequences corresponding to the data presented in Table 1 and the LORCAN-derived consensus sequences used as references in Fig. 3 were deposited in the European Nucleotide Archive under project accession number PRJEB34167 or made available as supplementary multi-FASTA files.
TABLE 1.
ATCC strain reference no. | Taxonomy |
LORCAN top consensus sequence |
SANGER consensus sequence leBIBI QBPP taxonomyb | LORCAN vs Sanger consensus sequence identity (%) | |
---|---|---|---|---|---|
LORCAN taxonomy | leBIBI QBPP taxonomyb | ||||
33560 | Campylobacter jejuni subsp. jejuni | Campylobacter jejuni | [Campylobacter lari subsp. concheus, Campylobacter jejuni subsp. jejuni*, Campylobacter jejuni subsp. doylei] (and 2 others) | [Campylobacter lari subsp. concheus, Campylobacter jejuni subsp. jejuni*, Campylobacter jejuni subsp. doylei] (and 2 others) | 99.77 |
43504 | Helicobacter pylori | Helicobacter pylori | [Helicobacter pylori*] | [Helicobacter pylori*] | 99.54 |
29212 | Enterococcus faecalis | Enterococcus faecalis | [Enterococcus faecalis*] | [Enterococcus faecalis*] | 100.00 |
25922 | Escherichia coli | Escherichia coli | [Escherichia marmotae, Escherichia fergusonii] Shigella flexneri* | [Shigella flexneri] | 99.57 |
49247 | Haemophilus influenzae | Haemophilus influenzae | [Haemophilus influenzae*] | [Haemophilus influenzae*] | 98.94 |
49226 | Neisseria gonorrhoeae | Neisseria gonorrhoeae | [Neisseria gonorrhoeae*] | [Neisseria gonorrhoeae*] | 100.00 |
27853 | Pseudomonas aeruginosa | Pseudomonas aeruginosa | [Pseudomonas tropicalis*, Pseudomonas aeruginosa, Pseudomonas hussainii] | [Pseudomonas tropicalis*, Pseudomonas indica, Pseudomonas aeruginosa] | 99.78 |
25923 | Staphylococcus aureus | Staphylococcus aureus | [Staphylococcus aureus subsp. anaerobius*] | [Staphylococcus argenteus, Staphylococcus aureus subsp. aureus, Staphylococcus schweitzeri*] (and 2 others) | 99.79 |
49619 | Streptococcus pneumoniae | Streptococcus pneumoniae | [Streptococcus pneumoniae*, Streptococcus pseudopneumoniae] | [Streptococcus mitis, Streptococcus pneumoniae*] | 99.79 |
29741 | Bacteroides thetaiotaomicron | Bacteroides thetaiotaomicron | [Bacteroides thetaiotaomicron*] | [Bacteroides thetaiotaomicron*] | 99.78 |
43055 | Eggerthella lenta | Eggerthella lenta | [Eggerthella lenta*] | [Eggerthella lenta*, Eggerthella timonensis] | 99.32 |
51299 | Enterococcus faecalis | Enterococcus faecalis | [Enterococcus faecalis*] | [Enterococcus faecalis*] | 100.00 |
8176 | Moraxella catarrhalis | Moraxella catarrhalis | [Moraxella canis, Moraxella catarrhalis*, Moraxella nonliquefaciens] | [Moraxella canis, Moraxella catarrhalis*] | 100.00 |
BAA-1705 | Klebsiella pneumoniae | Klebsiella pneumoniae | [Klebsiella variicola, Klebsiella quasivariicola*] | [Klebsiella pneumoniae subsp. rhinoscleromatis*, Klebsiella quasipneumoniae subsp. quasipneumoniae] | 98.93 |
13637 | Stenotrophomonas maltophilia | Stenotrophomonas maltophilia | [Stenotrophomonas maltophilia*] | [Stenotrophomonas maltophilia] | 100.00 |
Samples were analyzed in parallel by Sanger sequencing and with the LORCAN approach. The resulting consensus sequences were submitted to the online taxonomic identification platform leBIBI QBPP.
Square brackets indicate proximal clusters. Asterisks indicate closest sequences based on patristic distances.
RESULTS
We present a standardized laboratory workflow accompanied by a fully automated analysis pipeline, which together provide a sample-to-report solution for taxonomic identification of bacterial cultures based on amplicon sequencing of their 16S rRNA genes (Fig. 1). The laboratory workflow, which was tested and adjusted for parallel processing of up to 16 samples done manually by a single person (theoretically scalable up to 96 samples using automation), includes stringent quality control steps to guarantee consistent results. The whole procedure has been running under ISO/IEC 17025 accreditation standards since January 2019 in our microbial diagnostic department. The analysis pipeline is based on publicly available software components and runs on Linux servers or workstations. It automates quality control, demultiplexing, consensus sequence generation, taxonomic analysis based on the highly curated leBIBI 16S database, as well as report generation (text, PDF; see example report in the supplemental material). Turnaround time from raw amplicons to PDF reporting is about 8 h (consisting of 6 h wet lab, 1 h sequencing, and 1 h bioinformatic analysis). Validation of the sequencing results was conducted by direct comparison to Sanger sequencing with real clinical samples consisting of pure or mixed rRNA amplicons belonging to several bacterial genera (Bacteroides, Eggerthella, Enterococcus, Klebsiella, Mycobacterium, Campylobacter, Pseudomonas) of expected amplicon sizes of 500 bp (longer amplicons of ca. 900 bp were also successfully analyzed with the proposed pipeline; data not shown). Additionally, we created artificial amplicon and read mixtures from different bacterial species to assess the workflow’s performance and robustness when confronted with contaminated samples. We demonstrated that by combining ONT sequencing and LORCAN, the accuracy of Sanger sequencing can be closely matched (>99.6% sequence identity on average) and that mixed samples can be resolved at the single-base resolution level.
Validation of SNV discrimination and analysis of mixed samples.
To test the ability of LORCAN to resolve mixed samples, artificial mixtures were created by mixing either amplicons (Fig. 2A) or reads produced from pure samples (Fig. 2B and C; see also Fig. S1 and S2 in the supplemental material). The taxonomic identity of all involved strains was successfully recovered by LORCAN. The slightly lower amplicon length of Pseudomonas aeruginosa compared to those of Staphylococcus aureus and Enterococcus faecalis resulted in a slight underrepresentation of the latter in the mixtures (Fig. 2B) due to the narrow size window chosen for read size selection (the lower boundary of the size window around the modal read length is adjustable in the LORCAN command line). The mixture of two Mycobacterium species (97.6% sequence identity in the amplified region) (Fig. 2C) was accurately reproduced.
Influence of database completeness on consensus accuracy and taxonomic classification.
We analyzed the influence of reference database completeness on the resulting consensus quality and accuracy by creating incomplete reference databases, from which we excluded reference sequences if they were too close to the ideal reference sequence, and then performed LORCAN analysis with each of these truncated databases in turn. The genetic distances of the closest reference sequences in the reference database strongly influenced the accuracy of the resulting consensus sequences. For instance, Enterococcus faecalis showed the lowest consensus accuracy at 95% database identity (Fig. 3). This was caused by gaps in the closest reference sequence available. For databases with closest identities of ≤94%, the reference sequence with the identified gaps was absent and consensus quality increased again (see Fig. S3 and S4 in the supplemental material). Classification at the species level was, however, virtually unaffected in pure amplicons. The Eggerthella lenta data set contained a contamination of Pseudomonas stutzeri reads (0.8% of all reads), which did not influence classification when reference sequences that enabled the mapping of Eggerthella lenta reads were available. In the absence of sufficiently close reference sequences, the sample was misidentified (Fig. 3A). Information provided in the LORCAN report did, however, reveal that the Pseudomonas stutzeri consensus sequence was only based on 20 out of 850 reads, which therefore indicated a likely case of suboptimal taxonomic classification.
Validation of sequence consensuses generated by the combination of nanopore sequencing and LORCAN.
The comparison of 78 LORCAN-generated consensus sequences from 14 sequencing runs (including 49 clinical samples and 15 ATCC reference strains) to their corresponding Sanger sequences revealed an average sequence identity of 99.6% ± 0.6 (standard deviation). The positive control (originating from the same pool of amplicons) that was systematically sequenced in these 14 runs showed an average identity of 99.8% ± 0.2 to its corresponding Sanger sequence. All reference strains were correctly identified at the species level by LORCAN. Identification by leBIBI QBPP resulted in assignment of the expected species (lowest patristic distance) or the placement of the expected species in the proximal cluster of the query sequence (in the phylogenetic tree) in all but two cases. In these cases, the analyzed strains were placed in close neighborhood of the expected species in the phylogenetic tree produced by leBIBI QBPP (Table 1; see also Fig. S5 in the supplemental material).
Comparison of sequencing costs.
Costs per sample of the Sanger method were the lowest across different sequencing technologies (Fig. 4), provided the analyzed amplicons are pure and short enough to be covered by a single sequence at sufficient quality. Among the analyzed next-generation sequencing (NGS) methods, nanopore sequencing was by far the most cost-effective option particularly at throughputs of 24 to 48 samples. The high costs per sample for Illumina are mainly caused by the nonreusable sequencing cartridges (the full costs apply regardless of the number of processed samples) and the comparably high prices of the library preparation kits.
Effects of parameter modifications on LORCAN results.
We studied the influence of the read size fraction (relative to the modal read length) and the number of input reads on LORCAN consensus quality. In short, optimal results were obtained when reads shorter than 20 bases below the modal read length were excluded from the analysis (see Fig. S6 in the supplemental material). Further, we found 100 reads to be sufficient for the generation of high-quality consensus sequences (see Fig. S7, S8, and S9 in the supplemental material). The required number of input reads may vary with the taxonomic complexity of the analyzed samples and the resolution required by the operator. From a theoretical viewpoint (Fig. 1B, step 2), a total of 3,000 size-selected reads may allow for the creation of high-quality consensus sequences and reliable species identification for species contributing ≥3.3% of those 3,000 selected reads (i.e., when setting a minimum reference mapping depth of 100 reads in LORCAN, which corresponds to the minimum number of reads recommended for reliable consensus creation [see Fig. S7]). In most cases, however, even when a sample may consist of amplicons derived from a unique species, not all reads are assigned to the target species (e.g., due to read errors and/or the presence of highly similar sequences associated with other species in the reference database). Furthermore, demultiplexing and size selection could result in significant reduction of available reads. For illustrative purposes, during our last 11 sequencing runs consisting of 89 samples (including place-holder samples; see Library preparation in Materials and Methods), an average of 639,944 ± 267,704 basecalled reads were produced, while multiplexing on average 8 ± 3 barcoded samples per sequencing run. Read demultiplexing produced thereafter an average of 46,571 ± 22,129 reads per library (i.e., in 58% of all reads, both index sequences have been identified and assigned to the same barcode). This comparably high read loss resulted from the stringent demultiplexing parameters used (detection of both 5′ and 3′ barcodes required, exclusion of reads with internal barcodes), which may effectively prevent cross talk between libraries (32). Subsequent size selection (read length of −20 to +100 bp around the modal sequence length) resulted in an average of 43,265 ± 21,305 reads per barcode, which were available for further processing. Samples producing more than 3,000 reads of the expected amplicon size were further down-sampled (adjustable LORCAN parameter), resulting in an average number of used reads of 3,008 ± 6 reads per sample. All samples, controls, and place holders processed in these 11 sequencing runs were successfully taxonomically identified. Although species identification could have been achieved with a lower number of reads per sample, sequence production was fast (i.e., approximately 1 to 2 h for 1 million reads), and even if flow cells may have been reused up to four times, the maximal sequencing capacity of the flow cells was never utilized (see Table S2 in the supplemental material).
DISCUSSION
We present here the first sample-to-report solution for marker-gene-based taxonomic identification of bacterial cultures specifically designed for clinical applications. We extensively tested the influences of various analysis parameters and, therefore, provide a basis for optimal tuning of the LORCAN pipeline to specific requirements. We demonstrated that reads significantly shorter than the modal read length showed reduced mapability to reference sequences and that resulting consensus sequences were of reduced quality. No such observations were made when using reads from longer-length fractions (see Fig. S6 in the supplemental material). Therefore, we excluded reads that were significantly shorter than the mode of the read length distribution (by 20 bases) from the analysis with the corresponding command line parameter in LORCAN. With these parameters being set this way, accurate consensus sequences (≥99% identity to Sanger sequences produced from the same DNA) were reliably produced with as few as 100 size-filtered reads per sample (see Fig. S7 in the supplemental material), confirming previous findings (33).
Applicability to samples consisting of mixed amplicons was a key requirement during development of LORCAN, as contaminations are not rare in bacterial cultures derived from clinical samples. To exclude sources of variation due to fluctuations in wet laboratory processes, we analyzed artificially mixed amplicons based on pure reads generated from pure amplicons. LORCAN showed high robustness against such mixture events and was capable of quantitatively representing read compositions in mixed samples as long as the analyzed gene region and the used database provide the required taxonomic resolution. Nevertheless, we consider our approach as semiquantitative, as biases inherent to DNA extraction and amplicon generation might occur. In addition, the presence of near-identical reference sequences belonging to different species can result in elevated levels of background due to misassignment of a fraction of the reads. Although we could observe a likely bias due to this phenomenon (see Fig. S1 in the supplemental material), the bias did not prevent the correct taxonomic identification of the most abundant species in any of our experiments. Furthermore, this bias can be mitigated by choosing longer amplicons, and the planned improvement in read quality by ONT will likely improve discrimination under such conditions.
A number of studies on ONT-based marker gene analysis have been published over the past years, covering a range of different laboratory and computational approaches aiming to obtain high-quality sequences from ONT reads. Most computational workflows either include reference-based consensus generation or de novo assembly in combination with additional error correction steps. They were reported to perform similarly in terms of the accuracy of the produced sequences (12, 13, 15, 17, 33). De novo approaches are preferable when reference sequences are missing; however, so far, the only studies demonstrating “reference-free” consensus generation from complex samples (e.g., mock communities) relied on rather laborious wet lab procedures, such as rolling cycle amplification or unique tagging of the individual amplicons before sequencing (15, 16). Unlike previous studies, we specifically designed our workflow for clinical routine applications. Compatibility with mixed samples and time/cost efficacy were therefore key requirements, and comprehensive reference databases were readily available. We therefore chose a reference-based approach allowing us to separate reads originating from mixed cultures while using standard ONT protocols. Furthermore, and in contrast to most previous studies, we omitted consensus error correction, which is commonly applied to remove homopolymer errors from consensus sequences and assemblies produced from nanopore reads (12, 13), because we did not detect a negative influence of the latter errors in our taxonomic classification approach.
The strengths of our approach are that overall the procedure is faster, more flexible, and more cost-effective than Sanger or Illumina-based approaches, as it relies on both straightforward ONT protocols and automated sample analysis up to result reporting. In addition, nanopore sequencing is compatible with any amplicon size, which is a clear advantage over other existing sequencing technologies and also allows the processing and resolution of mixed amplicon samples as demonstrated here. Finally, even when the reference sequence database is incomplete or lacks closely related reference sequences, we showed that the approach is robust and provides correct taxonomic identification of the bacterial species.
Our approach has several limitations. (i) The taxonomic resolution is inherently limited by the choice of a single-gene-based approach. Commonly used 16S rRNA gene regions, for example, have been reported to allow for genus identification in >90% of cases, for species identification in 65% to 83% of cases and to result in unsuccessful identification in 1% to 14% of all analyzed isolates (8, 34, 35). Other approaches, such as matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) mass spectrometry may complementarily provide fast and reliable identification of clinically relevant microorganisms (36). Yet, MALDI-TOF may also suffer from suboptimal identification due to limitations, including insufficient representation of reference species profiles in available commercial databases, absence of newly discovered species, and the existence of several commercial systems (37–39). (ii) The dependency on database quality and completeness in the LORCAN reference-based approach for consensus building was explored extensively by using modified databases, which lacked reference sequences closely related to the analyzed strains. Not surprisingly, consensus accuracy was strongly affected, and LORCAN required reference databases of high quality and completeness to reliably reach sequence qualities on par with the quality obtained by the Sanger method. Even if databases contained sequences with up to 99% identity to the analyzed species, further improvements could often be made by adding closer reference sequences (Fig. 3). Importantly though for clinical diagnostics, taxonomic identification based on the produced consensus sequence was far less affected by database completeness. Even consensus sequences produced with distant reference sequences (≤90% identity to the query sequence using an incomplete database) allowed for reliable bacterial species identification when the generated consensus was compared to a complete database. This finding indicates a high reliability of the taxonomic identification despite the database dependency of the approach. This was confirmed by extensive validation in our diagnostics department, which was based on the parallel sequencing and analysis of clinical samples using both Sanger and nanopore sequencing over several months, which overall showed average sequence identities of 99.6% (and 99.8% for positive controls sequenced conjointly with the clinical samples). (iii) Finally, the wet laboratory procedures still take several hours and would need to be optimized to allow fast and efficient processing of several samples via automation or via simplified steps.
In conclusion, we demonstrate that the combination of nanopore sequencing and LORCAN pipeline offers a significant improvement over the well-established Sanger or short-read sequencing approaches in terms of reliability (robustness against contaminated samples) and flexibility (read length limited by PCR only), while offering comparable turnaround time, cost, and reproducibility of the results. The described workflow has great potential to be successfully introduced in the routine of diagnostic departments and may thus facilitate custom amplicon sequencing and further taxonomic identification of bacterial pathogens.
Supplementary Material
ACKNOWLEDGMENTS
We thank Christian Baumann for his excellent technical assistance and John W. Looney for his help in the preparation of technical documents.
The project was financed by the Institute for Infectious Diseases, University of Bern, Switzerland.
A.R. received travel grants from Oxford Nanopore Technologies to attend scientific conferences.
The sponsor had no role in the design, execution, interpretation, or writing of the study.
Footnotes
Supplemental material is available online only.
REFERENCES
- 1.Maruvada P, Leone V, Kaplan LM, Chang EB. 2017. The human microbiome and obesity: moving beyond associations. Cell Host Microbe 22:589–599. doi: 10.1016/j.chom.2017.10.005. [DOI] [PubMed] [Google Scholar]
- 2.Durban A, Abellan JJ, Jimenez-Hernandez N, Ponce M, Ponce J, Sala T, D’Auria G, Latorre A, Moya A. 2011. Assessing gut microbial diversity from feces and rectal mucosa. Microb Ecol 61:123–133. doi: 10.1007/s00248-010-9738-y. [DOI] [PubMed] [Google Scholar]
- 3.Janda JM, Abbott SL. 2007. 16S rRNA gene sequencing for bacterial identification in the diagnostic laboratory: pluses, perils, and pitfalls. J Clin Microbiol 45:2761–2764. doi: 10.1128/JCM.01228-07. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Srinivasan R, Karaoz U, Volegova M, MacKichan J, Kato-Maeda M, Miller S, Nadarajan R, Brodie EL, Lynch SV. 2015. Use of 16S rRNA gene for identification of a broad range of clinically relevant bacterial pathogens. PLoS One 10:e0117617. doi: 10.1371/journal.pone.0117617. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Zhang J, Fang Y, Hou JY, Ren HJ, Jiang R, Roos P, Dovichi NJ. 1995. Use of non-cross-linked polyacrylamide for four-color DNA sequencing by capillary electrophoresis separation of fragments up to 640 bases in length in two hours. Anal Chem 67:4589–4593. doi: 10.1021/ac00120a026. [DOI] [PubMed] [Google Scholar]
- 6.Heather JM, Chain B. 2016. The sequence of sequencers: the history of sequencing DNA. Genomics 107:1–8. doi: 10.1016/j.ygeno.2015.11.003. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Tenney AE, Wu JQ, Langton L, Klueh P, Quatrano R, Brent MR. 2007. A tale of two templates: automatically resolving double traces has many applications, including efficient PCR-based elucidation of alternative splices. Genome Res 17:212–218. doi: 10.1101/gr.5661407. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Mignard S, Flandrois JP. 2006. 16S rRNA sequencing in routine bacterial identification: a 30-month experiment. J Microbiol Methods 67:574–581. doi: 10.1016/j.mimet.2006.05.009. [DOI] [PubMed] [Google Scholar]
- 9.Nicholls SM, Quick JC, Tang S, Loman NJ. 2019. Ultra-deep, long-read nanopore sequencing of mock microbial community standards. GigaScience 8:giz043. doi: 10.1093/gigascience/giz043. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Srivathsan A, Baloğlu B, Wang W, Tan WX, Bertrand D, Ng AHQ, Boey EJH, Koh JJY, Nagarajan N, Meier R. 2018. A MinION-based pipeline for fast and cost-effective DNA barcoding. Mol Ecol Resour 18:1035–1049. doi: 10.1111/1755-0998.12890. [DOI] [PubMed] [Google Scholar]
- 11.Vaser R, Sovic I, Nagarajan N, Sikic M. 2017. Fast and accurate de novo genome assembly from long uncorrected reads. Genome Res 27:737–746. doi: 10.1101/gr.214270.116. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Menegon M, Cantaloni C, Rodriguez-Prieto A, Centomo C, Abdelfattah A, Rossato M, Bernardi M, Xumerle L, Loader S, Delledonne M. 2017. On site DNA barcoding by nanopore sequencing. PLoS One 12:e0184741. doi: 10.1371/journal.pone.0184741. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Maestri S, Cosentino E, Paterno M, Freitag H, Garces JM, Marcolungo L, Alfano M, Njunjic I, Schilthuizen M, Slik F, Menegon M, Rossato M, Delledonne M. 2019. A rapid and accurate MinION-based workflow for tracking species biodiversity in the field. Genes 10:468. doi: 10.3390/genes10060468. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Somerville V, Lutz S, Schmid M, Frei D, Moser A, Irmler S, Frey JE, Ahrens CH. 2019. Long-read based de novo assembly of low-complexity metagenome samples results in finished genomes and reveals insights into strain diversity and an active phage system. BMC Microbiol 19:143. doi: 10.1186/s12866-019-1500-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Calus ST, Ijaz UZ, Pinto AJ. 2018. NanoAmpli-Seq: a workflow for amplicon sequencing for mixed microbial communities on the nanopore sequencing platform. GigaScience 7:giy140. doi: 10.1093/gigascience/giy140. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Karst SM, Ziels RM, Kirkegaard RH, Albertsen M. 2019. Enabling high-accuracy long-read amplicon sequences using unique molecular identifiers and nanopore sequencing. bioRxiv doi: 10.1101/645903. [DOI] [PubMed]
- 17.Benitez-Paez A, Portune KJ, Sanz Y. 2016. Species-level resolution of 16S rRNA gene amplicons sequenced through the MinION portable nanopore sequencer. GigaScience 5:s13742-016-0111-z. doi: 10.1186/s13742-016-0111-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Kai S, Matsuo Y, Nakagawa S, Kryukov K, Matsukawa S, Tanaka H, Iwai T, Imanishi T, Hirota K. 2019. Rapid bacterial identification by direct PCR amplification of 16S rRNA genes using the MinION nanopore sequencer. FEBS Open Bio 9:548–557. doi: 10.1002/2211-5463.12590. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Ramette A. 2019. Long read consensus analysis (LORCAN). https://github.com/aramette/LORCAN/. Retrieved 27 August 2019.
- 20.Wick RR. 2018. Porechop. https://github.com/rrwick/Porechop. Accessed 5 April 2018.
- 21.Li H. 2018. Minimap2: pairwise alignment for nucleotide sequences. Bioinformatics 34:3094–3100. doi: 10.1093/bioinformatics/bty191. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Li H, Handsaker B, Wysoker A, Fennell T, Ruan J, Homer N, Marth G, Abecasis G, Durbin R, Genome Project Data Processing Subgroup. 2009. The sequence alignment/map format and SAMtools. Bioinformatics 25:2078–2079. doi: 10.1093/bioinformatics/btp352. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Shen W, Le S, Li Y, Hu F. 2016. SeqKit: a cross-platform and ultrafast toolkit for FASTA/Q file manipulation. PLoS One 11:e0163962. doi: 10.1371/journal.pone.0163962. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Altschul SF, Gish W, Miller W, Myers EW, Lipman DJ. 1990. Basic local alignment search tool. J Mol Biol 215:403–410. doi: 10.1016/S0022-2836(05)80360-2. [DOI] [PubMed] [Google Scholar]
- 25.Katoh K, Standley DM. 2013. MAFFT multiple sequence alignment software version 7: improvements in performance and usability. Mol Biol Evol 30:772–780. doi: 10.1093/molbev/mst010. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Castresana J. 2000. Selection of conserved blocks from multiple alignments for their use in phylogenetic analysis. Mol Biol Evol 17:540–552. doi: 10.1093/oxfordjournals.molbev.a026334. [DOI] [PubMed] [Google Scholar]
- 27.Nguyen LT, Schmidt HA, von Haeseler A, Minh BQ. 2015. IQ-TREE: a fast and effective stochastic algorithm for estimating maximum-likelihood phylogenies. Mol Biol Evol 32:268–274. doi: 10.1093/molbev/msu300. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Flandrois JP, Perriere G, Gouy M. 2015. leBIBIQBPP: a set of databases and a webtool for automatic phylogenetic analysis of prokaryotic sequences. BMC Bioinformatics 16:251. doi: 10.1186/s12859-015-0692-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Schloss PD, Westcott SL, Ryabin T, Hall JR, Hartmann M, Hollister EB, Lesniewski RA, Oakley BB, Parks DH, Robinson CJ, Sahl JW, Stres B, Thallinger GG, Van Horn DJ, Weber CF. 2009. Introducing mothur: open-source, platform-independent, community-supported software for describing and comparing microbial communities. Appl Environ Microbiol 75:7537–7541. doi: 10.1128/AEM.01541-09. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Devulder G, Perrière G, Bath F, Flandrois JP. 2019. leBIBI-QBPP BioInformatic Phylogeny of Prokaryotes - QBPP. https://umr5558-bibiserv.univ-lyon1.fr/lebibi/lebibi.cgi. Retrieved 7 February 2019.
- 31.Corpet F. 1988. Multiple sequence alignment with hierarchical clustering. Nucleic Acids Res 16:10881–10890. doi: 10.1093/nar/16.22.10881. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Xu Y, Lewandowski K, Lumley S, Pullan S, Vipond R, Carroll M, Foster D, Matthews PC, Peto T, Crook D. 2018. Detection of viral pathogens with multiplex nanopore MinION sequencing: be careful with cross-talk. Front Microbiol 9:2225–2225. doi: 10.3389/fmicb.2018.02225. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Pomerantz A, Penafiel N, Arteaga A, Bustamante L, Pichardo F, Coloma LA, Barrio-Amoros CL, Salazar-Valenzuela D, Prost S. 2018. Real-time DNA barcoding in a rainforest using nanopore sequencing: opportunities for rapid biodiversity assessments and local capacity building. GigaScience 7:giy033. doi: 10.1093/gigascience/giy033. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Woo PC, Ng KH, Lau SK, Yip KT, Fung AM, Leung KW, Tam DM, Que TL, Yuen KY. 2003. Usefulness of the MicroSeq 500 16S ribosomal DNA-based bacterial identification system for identification of clinically significant bacterial isolates with ambiguous biochemical profiles. J Clin Microbiol 41:1996–2001. doi: 10.1128/JCM.41.5.1996-2001.2003. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35.Drancourt M, Bollet C, Carlioz A, Martelin R, Gayral JP, Raoult D. 2000. 16S ribosomal DNA sequence analysis of a large collection of environmental and clinical unidentifiable bacterial isolates. J Clin Microbiol 38:3623–3630. doi: 10.1128/JCM.38.10.3623-3630.2000. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Keys CJ, Dare DJ, Sutton H, Wells G, Lunt M, McKenna T, McDowall M, Shah HN. 2004. Compilation of a MALDI-TOF mass spectral database for the rapid screening and characterisation of bacteria implicated in human infectious diseases. Infect Genet Evol 4:221–242. doi: 10.1016/j.meegid.2004.02.004. [DOI] [PubMed] [Google Scholar]
- 37.Sandalakis V, Goniotakis I, Vranakis I, Chochlakis D, Psaroulaki A. 2017. Use of MALDI-TOF mass spectrometry in the battle against bacterial infectious diseases: recent achievements and future perspectives. Expert Rev Proteomics 14:253–267. doi: 10.1080/14789450.2017.1282825. [DOI] [PubMed] [Google Scholar]
- 38.Psaroulaki A, Chochlakis D. 2018. Use of MALDI-TOF mass spectrometry in the battle against bacterial infectious diseases: recent achievements and future perspectives. Expert Rev Proteomics 15:537–539. doi: 10.1080/14789450.2018.1499469. [DOI] [PubMed] [Google Scholar]
- 39.Tsuchida S. 2018. Application of MALDI-TOF for bacterial identification, p 101–112. In Cobo F. (ed), The use of mass spectrometry technology (MALDI-TOF) in clinical microbiology. Academic Press, London, UK. [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
All reads and consensus sequences corresponding to the data presented in Table 1 and the LORCAN-derived consensus sequences used as references in Fig. 3 were deposited in the European Nucleotide Archive under project accession number PRJEB34167 or made available as supplementary multi-FASTA files.
TABLE 1.
ATCC strain reference no. | Taxonomy |
LORCAN top consensus sequence |
SANGER consensus sequence leBIBI QBPP taxonomyb | LORCAN vs Sanger consensus sequence identity (%) | |
---|---|---|---|---|---|
LORCAN taxonomy | leBIBI QBPP taxonomyb | ||||
33560 | Campylobacter jejuni subsp. jejuni | Campylobacter jejuni | [Campylobacter lari subsp. concheus, Campylobacter jejuni subsp. jejuni*, Campylobacter jejuni subsp. doylei] (and 2 others) | [Campylobacter lari subsp. concheus, Campylobacter jejuni subsp. jejuni*, Campylobacter jejuni subsp. doylei] (and 2 others) | 99.77 |
43504 | Helicobacter pylori | Helicobacter pylori | [Helicobacter pylori*] | [Helicobacter pylori*] | 99.54 |
29212 | Enterococcus faecalis | Enterococcus faecalis | [Enterococcus faecalis*] | [Enterococcus faecalis*] | 100.00 |
25922 | Escherichia coli | Escherichia coli | [Escherichia marmotae, Escherichia fergusonii] Shigella flexneri* | [Shigella flexneri] | 99.57 |
49247 | Haemophilus influenzae | Haemophilus influenzae | [Haemophilus influenzae*] | [Haemophilus influenzae*] | 98.94 |
49226 | Neisseria gonorrhoeae | Neisseria gonorrhoeae | [Neisseria gonorrhoeae*] | [Neisseria gonorrhoeae*] | 100.00 |
27853 | Pseudomonas aeruginosa | Pseudomonas aeruginosa | [Pseudomonas tropicalis*, Pseudomonas aeruginosa, Pseudomonas hussainii] | [Pseudomonas tropicalis*, Pseudomonas indica, Pseudomonas aeruginosa] | 99.78 |
25923 | Staphylococcus aureus | Staphylococcus aureus | [Staphylococcus aureus subsp. anaerobius*] | [Staphylococcus argenteus, Staphylococcus aureus subsp. aureus, Staphylococcus schweitzeri*] (and 2 others) | 99.79 |
49619 | Streptococcus pneumoniae | Streptococcus pneumoniae | [Streptococcus pneumoniae*, Streptococcus pseudopneumoniae] | [Streptococcus mitis, Streptococcus pneumoniae*] | 99.79 |
29741 | Bacteroides thetaiotaomicron | Bacteroides thetaiotaomicron | [Bacteroides thetaiotaomicron*] | [Bacteroides thetaiotaomicron*] | 99.78 |
43055 | Eggerthella lenta | Eggerthella lenta | [Eggerthella lenta*] | [Eggerthella lenta*, Eggerthella timonensis] | 99.32 |
51299 | Enterococcus faecalis | Enterococcus faecalis | [Enterococcus faecalis*] | [Enterococcus faecalis*] | 100.00 |
8176 | Moraxella catarrhalis | Moraxella catarrhalis | [Moraxella canis, Moraxella catarrhalis*, Moraxella nonliquefaciens] | [Moraxella canis, Moraxella catarrhalis*] | 100.00 |
BAA-1705 | Klebsiella pneumoniae | Klebsiella pneumoniae | [Klebsiella variicola, Klebsiella quasivariicola*] | [Klebsiella pneumoniae subsp. rhinoscleromatis*, Klebsiella quasipneumoniae subsp. quasipneumoniae] | 98.93 |
13637 | Stenotrophomonas maltophilia | Stenotrophomonas maltophilia | [Stenotrophomonas maltophilia*] | [Stenotrophomonas maltophilia] | 100.00 |
Samples were analyzed in parallel by Sanger sequencing and with the LORCAN approach. The resulting consensus sequences were submitted to the online taxonomic identification platform leBIBI QBPP.
Square brackets indicate proximal clusters. Asterisks indicate closest sequences based on patristic distances.