Abstract
Cardiovascular diseases (CVD) are the leading cause of death and morbidity in the world and are a major contributor to healthcare costs. Although enormous progress has been made in diagnosing CVD, there is an urgent need for more efficient early detection and the development of novel diagnostic tools. Currently, CVD diagnosis relies primarily on clinical symptoms based on molecular imaging (MOI) or biomarkers associated with CVDs. However, sensitivity, specificity, and accuracy of the assay are still challenging for early-stage CVDs. Nanomaterial platform has been identified as a promising candidate for improving the practical usage of diagnostic tools because of their unique physicochemical properties. In this review article, we introduced cardiac biomarkers and imaging techniques that are currently used for CVD diagnosis. We presented the applications of various nanotechnologies on diagnosis within cardiac immunoassays (CIAs) and molecular imaging. We also summarized and compared different cardiac immunoassays based on their sensitivities and working ranges of biomarkers.
Keywords: cardiovascular disease (CVD), biomarker, molecular imaging, diagnostic, nanotechnology
Introduction
Cardiovascular diseases (CVDs) are the most common causes of death in the world (Ho, 2018). CVDs can be medically defined as a group of disorders involving heart, brain, and blood vessels, including but not limited to coronary heart diseases, peripheral arterial diseases, rheumatic heart diseases, deep vein thrombosis, and cerebrovascular diseases – all of which result in ischemia and tissue death (Yang et al., 2009, 2012; Laflamme et al., 2012; Chakrabarti et al., 2013; Yu et al., 2015; Fan et al., 2020a, b). General CVDs can be characterized into five categories: atherosclerosis, acute myocardial infarction (AMI), heart failure (HF), stroke, and hypertension (Lichtenstein and Matthan, 2007; Govindappa et al., 2020; Joshi et al., 2020). Individuals who demonstrate tobacco smoking, high levels of low-density lipoproteins (LDL)-associated cholesterol, glucose, and diabetes as well as overweight and obesity, are especially susceptible to CVD morbidity and mortality (D’Agostino et al., 2008). Effectively diagnosing individuals who are most susceptible to CVDs opens the door to optimal treatment, thereby lowering the death rate. Given that early-stage CVDs demonstrate a high survival rate, predicting CVDs early on is essential.
Current common clinical CVD diagnosis methods include electrocardiography (ECG), plain X-ray, computed tomography (CT), and magnetic resonance imaging (MRI), and other MOI techniques (Anderson et al., 2013). ECG measures variations in the conduction system of the heart and monitors chest pain in AMI patients (Fesmire et al., 1998). CT scans X-ray images around the body and generates slices images of bones, blood vessels and tissues, which is appropriate for CVD diagnosis on grounds of its high signal contrast and accuracy (Kirkpatrick et al., 2003). MRI has been widely used in atherosclerosis and stroke detection given it scans three-dimensional images of bodies in a non-invasive manner (Pykett et al., 1983). However, these traditional methods were limited to low sensitivity and specificity.
To overcome these aforementioned difficulties, various new platforms such as cardiac immunoassays (CIAs) and advanced molecular imaging (MOI) were introduced, which significantly improved the efficiency of CVD diagnosis over the past decades (Qureshi et al., 2012; Osborn and Jaffer, 2013). Cardiac biomarkers are substances in the blood when the heart and brain are damaged or act abnormally. For example, cardiac troponin I (cTnI) has been demonstrated as a promising biomarker for AMI (Apple et al., 1997). MOI is capable of identifying cellular and molecular biology process, however, each technique has advantages and limitations. Therefore, advanced MOI combined different MOI techniques have been invented (e.g., dual-module, triple-module-CT) to obtain more detailed imaging information, which has increased the accuracy of diagnostic results (Hur et al., 2011, 2012).
Despite the great merits of previous methods, early-stage diagnosis is still challenging due to its complex pathophysiology, vague symptoms, and low expression levels of cardiac biomarkers. These difficulties increase the aggravation and mortality of CVDs. For instance, atherosclerosis shows no signs or symptoms and extremely low-level of related biomarkers in some patients even after a heart attack (Libby, 2002). Moreover, quick and convenient measurements are inadequate in addressing the expanded needs of CVD patients. Hence, rapid, accurate, and highly sensitive and specific platforms are needed for early-stage CVDs.
Nanotechnology involves nanoscale dimension systems (Johnson, 2012; Zhou et al., 2014), has specific physicochemical properties that make them appealing for improving current diagnosis (Kuriyama et al., 2011; Sun et al., 2016, 2019; Chen Z. et al., 2017; Liu et al., 2017; Yang et al., 2020a). Nanomaterials have been extensively applied to CIAs, including electrochemiluminescence (ECL), Electrochemical (EC), and photoelectrochemistry (PEC) due to their unique optical property, electrical property, and excellent biocompatibility (Figure 1) (Abdorahim et al., 2016). For example, Gold nanoparticles (AuNPs) can be incorporated with biotinylated antibodies to reduce non-specific binding, or conjugated with biomolecules with specific physical properties [e.g., hybridization chain reaction (HCR)] for signal amplification. Liu G. et al. (2016) detected cTnI via antigen-antibody affinity with a low limit of detection using AuNPs and graphene oxide. AuNPs and other metal nanoparticles can modify substrates (e.g., boron nitride nanosheets, titanium) in EC assays as well because of their attractive electrical properties (Golberg et al., 2010). Other nanomaterials, like silica/Pt NPs, are common signal enhancers in PEC and surface plasmon resonance (SPR) thanks to their efficient photocurrent quenching ability and unique plasmonic properties (Homola et al., 1999). Besides, upconversion nanoparticles (UCNPs) have been used in fluorescence assay because of their excellent photon conversion ability (Haase and Schäfer, 2011). Also, knotted and hollow nanomaterials (e.g., nanosheets, nanotubes, nanowires, and nanoclusters) with the large surface area that increases loading efficiency of biomolecules for signal enhancement (Kong et al., 2000). Nanomaterials also play important roles in MOI. Nanomaterials coupled with photoacoustic, fluorescent, radioactive, paramagnetic substances can work as contrast agents in MOI settings to enhance their detection signal (Van Schooneveld et al., 2010).
In this review, we will introduce the recent progress of nanotechnology for diagnosing CVDs. The nanotechnology facilitated CIA and MOI applications will be covered. Firstly, we summarized common clinical cardiac biomarkers and MOI settings. Then the applications on nanotechnology to identify cardiac biomarkers within different platforms based on unique properties of various nanomaterials will be introduced, including ECL, fluorescence, PEC, EC Surface-enhanced Raman scattering (SERS), SPR, Field effect transistor (FET), Enzyme-Linked Immunosorbent Assay (ELISA), and lateral flow assay (LFA). We compared different CIAs based on their sensitivities and working ranges of cardiac biomarkers as well. Besides, we concluded current diagnosis achievements on MOI with the help of functionalized nanoparticle.
CVD Diagnostic Settings
Cardiac Immunoassay (CIA)
Cardiac biomarkers present in human bodyfluids are reliable and reproducible indicators of the risk and progression of CVDs. They can be detected and quantified through various CIAs based on antigen-antibody immunoaffinity. Measuring expression levels of cardiac biomarkers within CIAs shows advantages, including high sensitivity, rapid, cheap, and non-invasive for the prediction and diagnosis of disease. Cardiac biomarkers can be classified as circulating biomarkers and exosomal biomarkers. Circulating biomarkers present in bodyfluids freely, and exosomal biomarkers are bound into or on the surface of extracellular vesicles (EVs) that are mobile and secreted from cells.
Cardiac Circulating Biomarkers
Circulating biomarkers include miRNA, mRNA, long-non-coding RNA, proteins, and other substances that present in human blood, milk, saliva, urine, and cerebral spinal biofluids (Durrani-Kolarik et al., 2017; Wang et al., 2017a, b; Wang X. et al., 2018; Yang et al., 2020b). Currently, several cardiac biomarkers, such as cardiac troponin I (cTnI), troponin I (TnI), myoglobin (MB), C-reactive protein (CRP), and creatine kinase-MB (CK-MB), have attracted interests as potential biomarkers for AMI (Christenson and Christenson, 2013). Particularly, cTnI has high specificity and sensitivity toward AMI (Jo et al., 2015), and MB is a good candidate for early diagnosis of AMI (Korff et al., 2006). Myeloperoxidase (MPO), glycogen phosphorylase isoenzyme BB (GPBB), B-type natriuretic peptide (BNP), N-terminal pro-B-type natriuretic peptide (NT-proBNP), C-type natriuretic peptide (c-TNP), Matrix metalloproteinase-8 (MMP-8), MMP-9 and tissue inhibitor of MMP-8 (TIMP-1), and leukotriene B4 are promising biomarkers as well (Anderon, 2005).
Recently, researchers discovered that some miRNAs circulating in serum or plasma were closely correlated with CVDs. For example, miR-208 was undetectable in healthy donors but was detected successfully in 90.9% of AMI patients (Ji et al., 2009). There are almost 50 circulating miRNAs proven to be relevant to CVDs. Specifically, miR-208a, miR-208b, and miR133 are up-regulated AMI biomarkers, while miR150, let-7b, and miR-126 are down-regulation AMI biomarkers (Corsten et al., 2010; Wang et al., 2010; Gidlöf et al., 2011; Long et al., 2012a, b; Devaux et al., 2013; Friese et al., 2013; Li et al., 2013). Furthermore, miR-423, miR-18b, miR-499, miR-142, miR-320a, miR-22, miR-20b, and miR-26b are positively associated with HF, but miR-103 is shown to be low in HF patients (Corsten et al., 2010; Tijsen et al., 2010; Goren et al., 2012; Ellis et al., 2013; Marfella et al., 2013). Additionally, let-7e, Hcmv-miR-UL112, miR-605, miR623, miR-516b, miR-132 are found to be relatively high in plasma in hypertension cases. In contrast, miR-296, miR-133b, miR-625, miR-1236 are down-regulation biomarkers (Li et al., 2011). Moreover, miR-145, miR21 are up-regulating biomarkers for strokes, and miR-221, miR-210, miR-30a, and miR-126 are shown to be low in human blood in stroke cases (Zeng et al., 2011; Gan et al., 2012; Long et al., 2012b; Tsai et al., 2013). In summary, circulating miRNAs are relatively stable and serve as sufficiently sensitive biomarkers for CVD diagnosis.
Cardiac Exosomal Biomarkers
EVs are submicron-sized vesicles ranging from 30 to 1000 nm secreted by cells. EVs play important roles in transferring proteins, mRNA, miRNA, and other molecules among cells (Yang et al., 2016; Ma et al., 2019; Walters et al., 2019; Liu et al., 2019). Increasing evidence showed that exosomal miRNAs are involved in the pathogenesis of CVDs (Zamani et al., 2019). It has been observed that exosomal miRNAs mediate intercellular communication in cardiovascular systems and play an indispensable role in the control of cellular functions (Bang et al., 2014). As such, exosomal miRNAs can be used as biomarkers for diagnosing subjects with CVDs (Rehman et al., 2017).
Recently, researchers found miR-1, miR-133a, miR-21, and miR-499 are AMI-related biomarkers (Cheng et al., 2012; Oerlemans et al., 2012). Also, miR-192, miR-194, miR-34a, miR-423-5p, miR320a, miR-22, and miR-92b are highly associated with HF (Goren et al., 2012; Matsumoto et al., 2013). Besides, miR-223 isolated from serum EVs is a potential biomarker for stroke (Chen Y. et al., 2017). Additionally, exosomal membrane proteins or internal proteins, such as TNF-α and fibronectin are also potential CVD biomarkers (de Jong et al., 2012; Yu et al., 2012). Table 1 summarized the biomarkers mentioned above.
TABLE 1.
Biomarker ID | Type | Pathology | Expression | References |
cTnI, TnI, MB, C-CRP, CK-MB, MPO, GPBB, NT-proBNP, c-TNP, MMP-8, MMP-9, TIMP-1, leukotriene B4, TNF-α, and fibronectin | Protein | AMI, HF, Hypertension, Stroke | Upregulated | Anderon, 2005; Korff et al., 2006; de Jong et al., 2012; Yu et al., 2012; Christenson and Christenson, 2013; Jo et al., 2015 |
miR-208, miR-208a, miR-208b, miR133, miR-1, miR-133a, miR-21, and miR-499 | RNA | AMI | Upregulated | Ji et al., 2009; Corsten et al., 2010; Wang et al., 2010; Gidlöf et al., 2011; Cheng et al., 2012; Long et al., 2012a, b; Oerlemans et al., 2012; Devaux et al., 2013; Friese et al., 2013; Li et al., 2013 |
miR150, let-7b, and miR-126 | RNA | AMI | Downregulated | Devaux et al., 2013; Friese et al., 2013; Li et al., 2013 |
miR-423, miR-18b, miR-499, miR-142, miR-320a, miR-22, miR-20b, miR-26b, miR-192, miR-194, miR-34a, miR-423-5p, miR320a, miR-22, and miR-92b | RNA | HF | Upregulated | Corsten et al., 2010; Tijsen et al., 2010; Goren et al., 2012; Ellis et al., 2013; Marfella et al., 2013; Matsumoto et al., 2013 |
miR-103 | RNA | HF | Downregulated | Ellis et al., 2013 |
let-7e, Hcmv-miR-UL112, miR-605, miR623, miR-516b, miR-132 | RNA | Hypertension | Upregulated | Li et al., 2011 |
miR-296, miR-133b, miR-625, miR-1236 | RNA | Hypertension | Downregulated | Li et al., 2011 |
miR-145, miR21, miR-223 | RNA | Stroke | Upregulated | Zeng et al., 2011; Gan et al., 2012; Long et al., 2012b; Tsai et al., 2013; Chen Y. et al., 2017 |
miR-221, miR-210, miR-30a, and miR-126 | RNA | Stroke | Downregulated | Zeng et al., 2011; Long et al., 2012b |
Molecular Imaging
Molecular imaging (MOI) is a common diagnostic tool for CVD in clinical practice. When paired with other approaches, MOI can reveal individual biology, including blood vessels, the brain, and the heart (Jaffer et al., 2007). Common MOI approaches include photoacoustic tomography (PAT), MRI, CT, positron emission tomography (PET), and single photon emission computed tomography (SPECT). PAT utilizes the photoacoustic effect that converts optical adsorption into acoustic energy and generates high-resolution imaged under optically ballistic and diffusive modules (Xia et al., 2014). Various materials such as dyes, nanoparticles, and probes can work as functional contrasts in PAT for vascular imaging (Li and Wang, 2009). CT takes X-ray images from different angles around the human body and produces cross-sectional images of the body to reveal blood vessels, tissues and organs (Article, 2018). MRI generates anatomical images based on the changes of protons in the body with a strong magnetic field (Hashemi et al., 2012). MRI sensors first turn on the radiofrequency current that spins the protons out of equilibrium and then detects the time and amount of released energy of realigning randomized protons within the magnetic field after turning off the radiofrequency current (McRobbie et al., 2017). Detected parameters are translated into images for diagnosis. PET uses injected radioactive tracers to review and evaluate tissues. The radiotracers used in PET produce positrons after decaying. Positrons react with electrons and produce photons that aggregate in specific, disease-related areas of the human body (Shan et al., 2013). The combination of PET with CT or MRI can create detailed, specific images. Similar to PET, SPECT provides tomographic images by recording and translating the activities of radioactive tracers that have gamma ray emissions (Hutton, 2014).
Nanotechnology-Based Cardiac Immunoassay
Various advanced techniques like ECL, PEC, SERS, SPR, and ELISA have been utilized to detect cardiac biomarkers with precision. Despite satisfactory results from previous methods, pursuing high sensitivity and accuracy in testing results is still an ongoing endeavor. Combining nanotechnologies with cardiac immunoassays may serve as a solution for early-stage CVD diagnosis. Nanotechnologies may reduce non-specific binding sites, provide high binding efficiency of cardiac targets, offer excellent signal amplification, and possess multiple functions. Table 2 summarized and compared performances of recent cardiac immunoassays based on various nanotechnology platforms.
TABLE 2.
Target | Assay | Nanoplatform | Range | Detection limit | References |
cTnI | ECL | Au nanocluster | 5 fg/mL to 50 ng/mL | 1.01 fg/mL | Zhu et al., 2019 |
ECL | Ag Nanoparticles | NA | 0.58 fg/mL | Wang et al., 2019 | |
ECL | QDs | 0.17–3 ng/mL | 0.02 ng/mL | Lakshmanakumar et al., 2019 | |
Fluorescence | QDs | 1 pg/mL to 10 ng/mL | 0.227 pg/mL | Miao et al., 2019 | |
Fluorescence | Pd-Ir nanocubes | 1 pg/mL to 1 ng/mL | 0.31 pg/mL | Tan et al., 2019 | |
Fluorescence | AuNP | NA | 0.019 ng/mL | Han and Kim, 2019 | |
PEC | QDs | 0.5 pg/mL to 10 ng/mL | 0.5 pg/mL | Xue et al., 2019 | |
PEC | Nanospheres and QDs | 0.08 ng/mL to 40 ng/mL | 0.026 ng/mL | Dong et al., 2020 | |
PEC | Mesoporous silica nanoparticles | 1.2 fg/mL to 20 ng/mL | 0.47 fg/mL | Gao et al., 2019 | |
EC | AuNPs | 1–1100 pM | 0.18 pM | Lopa et al., 2019 | |
EC | Carbon nanotubes | NA | 0.05 ng/mL | Vasantham et al., 2020 | |
EC | Nanospheres | 0.005 ng/mL to 100 ng/mL | 5 pg/mL | Singh et al., 2019 | |
EC | Carbon nanotubes | 0.05 ng/mL to 30 ng/mL | 0.03 ng/mL | Shen et al., 2019 | |
EC | Nanorods | 0.01 ng/mL to 10 ng/mL | NA | Sandil et al., 2019 | |
EC | Nanocubes | NA | 33.3 fg/mL | Zhang et al., 2019 | |
EC | Nanoparticles | 1.0 pg/mL to 100 ng/mL | 0.39 pg/mL | Ma et al., 2019 | |
EC | Nanocubes | 100 fg/mL to 250 ng/mL | 33 fg/mL | Lv et al., 2019 | |
SERS | AuNPs | 0.01 ng/mL to 1000 ng/mL | 5 pg/mL | Fu et al., 2019 | |
SPR | AuNPs | NA | 3.75 ng/mL | Chen et al., 2019 | |
FET | Nanoribbon | NA | 1 pg/mL | Liu Q. et al., 2016 | |
ELISA | Nanodendrites | 0.1 pg/mL to 1000 ng/mL | 0.056 pg/mL | Jiao et al., 2019 | |
LFA | AuNPs | NA | 0.1 ng/mL | Lim et al., 2019 | |
LFA | Nanosphere | 0.049 ng/mL to 50 ng/mL | 0.049 ng/mL | Lou et al., 2019a | |
LFA | Nanosphere | 0.1 ng/mL | Lou et al., 2019b | ||
NT-proBNP | ECL | Nanocube and AuNPs | 0.25 pg/mL to 100 ng/mL | 0.11 pg/mL | Dong et al., 2019 |
MB | ECL | AuNPs and platinum nanowires | 3.0 ng/mL to 0.32 μg/mL | 0.11 ng/mL | Zou et al., 2019 |
Fluorescence | UCNPs | 10 ng/mL to 400 ng/mL | 0.21 ng/mL | Ji et al., 2019 | |
EC | AuNPs and nanosheets | 0.1 μg/mL to 100 μg/mL | 34.6 ng/mL | Adeel et al., 2019 | |
cTnT | EC | Carbon nanotubes | 0.1 pg/mL to 8.0 pg/mL | 0.04 pg/mL | Phonklam et al., 2020 |
BNP | FET | Nanoribbon | 10 pg/mL | Liu Q. et al., 2016 | |
FABP | Fluorescence | Nanowires | 2.5–60 ng/mL | 1.36 ng/mL | Guo et al., 2019 |
CK-MB | ECL | AuNPs, Fe3O4, carbon nano-onions | 10 ng/mL to 50 fg/mL | 5 fg/mL | Adhikari et al., 2019 |
SERS | AuNPs | NA | 9.7 pg/mL | Cheng et al., 2019 | |
FET | Nanoribbon | NA | 0.1 ng/mL | Liu Q. et al., 2016 | |
LFA | AuNPs | NA | 5 ng/mL | Lim et al., 2019 | |
Vaspin | Fluorescence | UCNPs | 0.1 ng/mL to 55 ng/mL | 39 pg/mL | Ali et al., 2020 |
GPBB | LFA | AuNPs | NA | 10 ng/mL | Lim et al., 2019 |
Electrochemiluminescence (ECL) Immunoassay
Electrochemiluminescence (ECL) involves electron-transfer reactions that generate excited states and light emission, thus works as a common diagnostic assay to quantify expression levels of biomarkers because detected emission intensity in ECL is proportional to the concentration of the biomarkers (Richter, 2004). Luminol is one of the most important signal enhancers in ECL but has a weak signal and poor solubility. Fortunately, luminol-functionalized nanomaterials can overcome the limitations of traditional luminol and greatly enhance the intensity and sensitivity due to their large specific surface area (e.g., carbon nanotubes, nanosheets), the ability to functionalize signal amplification materials (e.g., nucleic acid isothermal amplification, HCR signal amplification), conductivity, and surface charge. All of these advantages have contributed to intense attention of ECL assay in biomolecule analysis (Hao et al., 2014; Feng et al., 2016).
Dong et al. (2019) detected NT-proBNP using ECL immunoassay based on ECL resonance energy transfer (RET). The ECL-RET transfer was between semicarbazide-modified gold nanoparticles (AgNC-sem@AuNPs) covered nanocubes (donor) and a Ti (IV)-based metal-organic framework of type MIL-125 (receptor). The partial overlap between the ECL emission of the AgNC-sem@AuNPs and the visible adsorption spectrum of MIL-135 created RET. The schematic was illustrated in Figure 2A. Firstly, 8 μL of AgNC-sem@AuNP solution was dropped on the pre-cleaned glassy carbon electrode (GCE) surface, then the primary antibody1 (Ab1) was immobilized on it via Au-NH2 bond. Then, NT-proBNP analytes were added to the assay and captured by Ab1. Finally, the MIL-125 labeled secondary antibody2 (Ab2) was incubated onto the electrode to form the sandwich format and quench the ECL strength of luminophore. The assay was able to recover 96.8%∼100.2% of NT-proBNP and detect it as low as 0.11 pg/mL.
Zhu et al. (2019) detected cTnI using Au Nanocluster and HCR signal amplification. A sandwich immunocomplex composed of cTnI, Ab1, and Ab2-AuNP-T1 was applied. Ab2-AuNP-T1 is a smart probe in which the DNA initiator strands (T1) and Ab2 are conjugated onto the AuNPs. The schematic was illustrated in Figure 2B. Once the cTnI was caught, the initiator strands T1 of Ab2-AuNP-T1 opened the hairpin DNA structures (H1 and H2) that were dual-labeled on the Au nanoclusters (Au NCs). This process triggered hybridization events, thus modified a large number of Au NCs on the surface of the electrode. Finally, a strong ECL signal was emitted owing to the reaction of the modified Au NCs and the coreactant K2S2O2. This ECL-HCR sensor was able to detect 1.01 fg/mL cTnI with high specificity stability and reproducibility.
Recently, various research groups have made great progress in CVD diagnosis using ECL assay. Wang et al. (2019) combined Co2+-based metal organic frameworks (MOF), zeolitic imidazolate frameworks (ZIF-67), and luminol-capped Ag nanoparticles (luminol-AgNPs) for fast and ultrasensitive detection of cTnI, with a 0.58 fg/mL detection limit. Zou et al. (2019) developed an ECL immunosensor to detect MB in human serum. They fabricated a basal electrode using AuNPs and platinum nanowires that were deposited onto indium tin oxide-coated glass linked with 3-aminopropyl-trimethoxysilane. Besides, Adhikari et al. (2019) presented an ultrasensitive label-free ECL immunosensor for CK-MB detection using a novel nanocomposite-modified printed electrode. To fabricate this sensor, carbon nano-onions (CNOs)/Fe3O4/AuNP/chitosan (CS) nanocomposite was dropped in single-layered rolled-up carbon nanotubes (SWCNTs). Then Ab1 against CK-MB was spiked onto the electrode and blocked by bovine serum albumin (BSA). Once CK-MB was captured on the electrode, the ECL signal was determined by Tris(2,2′-bipyridyl)-ruthenium(II) chloride ([Ru(bpy)3]2+Cl) and tri-n-propylamine (TPrA), in which Ru(bpy)3]2+Cl was used as luminophore and TPrA was the co-reactant. Moreover, Lakshmanakumar et al. (2019) functionalized graphene quantum dots with acetic acid (fGQDs) on the Au electrode to detect cTnI. The cTnI was recognized via carbodiimide conjugation between the N-H group of cTnI and the COOH group on fGQDs instead of antibody-antigen interaction. The interaction of cTnI and fGQDs was examined by cyclic voltammetry (CV) and amperometry (Lakshmanakumar et al., 2019). They detected cTnI over a linear range of 0.17–3 ng/mL and offered a detection limit of 0.02 ng/mL with good stability and sensitivity. Based on the aforementioned discussion, ECL immunoassay is appealing for diagnosis since its high stability as well as sensitivity and specificity. Despite the considerable advantages for biomedical analysis, ECL often requires specialized and expensive equipment for generating excited states with light-emitting for detection, which to some extent impair its extensive application.
Fluorescence Immunoassay
Fluorescence immunoassay is by far the dominant analytical approach in biomedical engineering on account of its outstanding versatility and signal enhancement ability (Strianese et al., 2012). Nanomaterials have promoted the efficiency of fluorescence assay because nanomaterials have good solubility, low toxicity, and high binding affinity of biomolecules, which can couple with various intensive fluorescence materials for amplification (e.g., Horseradish Peroxidase) (Yeh et al., 2010; Lu et al., 2017).
Miao et al. (2019) used a robust nanoceria-linked immunosorbent assay to detect cTnI based on colorimetric and ratiometric fluorescence. Ratiometric fluorescence overcomes some dependence defects, such as external environment luminophore, consequently, it can be used for trace detection. The schematic of the sensor was illustrated in Figure 2C. After the bonding of cTnI and Ab1, o-phenylenediamine (OPD) as an organic substrate was oxidized and converted into 2,3-diaminophenazine (oxOPD) by the robust nanozyme of nanoceria with peroxidase-like properties and the addition of H2O2. OxOPD was immobilized on the surface of g-C3N4 QDs through hydrogen bonding and π–π stacking interactions. The g-C3N4 QDs led to a ratiometric fluorescence response as a result of photoinduced electron transfer (PET). Besides, a visible color change was detected through the conversion of colorless OPD to an orange oxOPD, which acted as a colorimetric fluorescence. As a result, cTnI was quantified by combining the merits of the ratiometric assay and colorimetric assay. Similarly, Tan et al. (2019) oxidized the OPD to oxOPD through the Pd-Ir nanocubes catalysis, which possessed excellent peroxidase-like activity. The detection range of cTnI was between 1 pg/mL to 1 ng/mL, and the detection limit was 0.31 pg/mL.
Moreover, Guo et al. (2019) completed multiplexed detection of cTnI, human heart-type fatty acid binding protein (FABP), and MB using Zinc Oxide Nanowires to enhance fluorescence signal. Han and Kim (2019) designed a AuNP-Antibody-HRP conjugate for cTnI detection. They bound aldehydeactivated(ald)HRP and the primary amine group based on adsorption or covalent coupling, to enhance the sensitivity of the AuNP-based conjugates.
Upconversion nanoparticles (UCNPs) are another type of fluorescent nanomaterials that have been used in luminescent and fluorescent detection (Tan et al., 2016). Ji et al. (2019) used core-shell upconversion nanoparticles (UCNP) to capture the MB in blood samples. MB was fixed between UCNPs-Ab1 and second anti-(MB Ab1) antibody to form a sandwich format. UCNPs were excited by a continuous wave laser diode at 908 nm for fluorescent reading by external equipment. The detailed procedure was illustrated in Figure 2D. Applied UCNPs increased the sensitivity of the assay, which reached a limit of detection as low as 0.21 ng/mL with a 90.6–110.5% MB recovery rate (Ji et al., 2019). Ali et al. (2020) also designed a biosensor assisted with UCNPs for ultrasensitive detection of Vaspin.
Photoelectrochemical (PEC)
The photoelectrochemical (PEC) process refers to the electricity conversion of photons resulting from photoactive materials absorbing photons upon illumination and forming electron-hole pairs. This, in turn, causes the oxidization-reduction reaction of the molecules and generates charge separation and subsequent charge transfer. PEC is a promising diagnostic tool since the detected photocurrent change is caused by the biological interactions between biomarkers and corresponding recognitions (Zhao et al., 2014). Nanomaterials have improved the sensitivity of PEC assay because they present a low background signal. For instance, AuNPs, QDs, TiO2 nanotubes (NTs), Pt NPs, and Silica NPs are suitable candidates for PEC biosensors thanks to their efficient photocurrent quenching ability and unique plasmonic properties (Zhao et al., 2012).
Xue et al. (2019) reported a split-type liposomal PEC immunoassay composed of immunoaffinity, cadmium sulfide (CdS) quantum dots-loaded liposomes (QDLL), and TiO2 nanotubes (NTs) that capture QDs for cTnI detection. The thioglycolic acid (TGA)-capped QDs and QDLL were linked with the Ab2 as signaling probes. The schema was explained in Figure 3A. cTnI was captured by Ab1 in the 96-well plates, and then QDLL-Ab2 was introduced after the immunorecognition. Triton X-100 (10%) was introduced to damage the QDLL and release the QDs that were later captured by the TiO2-NTs electrode. TGA-capped CdS QDs reacted with the Titania surface through the complexing between the carboxylic acid functionality on the CdS QDs and the hydroxyl groups of the TiO2 NTs – via either chelating or bidentate binding modes (or both). Owing to the sensitization effect, the photocurrents were acquired for PEC immunoassay.
Similarly, Dong et al. (2020) modified the indium tin oxide-polyethylene terephthalate (ITO-PET) electrode with Bi2Se3 and the flower-like ZnIn2S4 nanospheres (ZIS). The latter was synthesized by a solvothermal method, which accelerated the electronic transition and improved the photocurrent conversion efficiency. Additionally, the cadmium selenide (CdSe) QDs, which modified Ab2, were able to increase the photocurrent blocked by immunoaffinity binding. This resulted in a detection limit of 0.026 ng/mL of cTnI (Dong et al., 2020).
Gao et al. (2019) fabricated cellulose paper-based, single-crystalline, three-dimensional aloe like TiO2 arrays (PSATs) as the electron transporting material. It was subsequently coupled with CdS to form PSATs/CdS to extend the solar spectrum response for cTnI detection (Figure 3B) (Gao et al., 2019). Single stranded DNAs (ssDNAs) that bound to cTnI specifically were coupled with positive-charged mesoporous silica nanoparticles (PMSNs). The complexes were prepared as the nanocarrier to entrap the Cu2+, which was regarded as a signal quencher because of its reaction with CdS to form CuxS. After the formation of cTnI-ssDNAs complexes, Cu2+ formed CuxS, which decreased the photocurrent signal. This process was used to quantify the concentration of cTnI.
Despite the accomplishments of PEC assay in CVD diagnosis, PEC assay has some disadvantages, especially the inherent drawback of photoanodes. For example, the CdS photoanodes of PEC might have low charge separation and transfer efficiency. Notably, they are unstable in water upon illumination as well.
Electrical and Reduction
Electrochemical (EC) immunoassay has attracted considerable attention and is one of the most promising techniques for diagnosis owing to its high sensitivity and fast response time. Besides that, nanomaterials are highly appreciated for improving EC sensitivity and intensity because of their catalytic property, conductivity, binding affinity, and large surface area. Like, AuNPs can bind biomolecules and facilitate electron transfer for catalyzing electrochemical reactions (Zhang et al., 2014). Besides, nanosheets and other hollow-structured nanomaterials can increase the loading efficiency of agents on grounds of their large surface area that enhances signal (Zhu et al., 2017).
Lopa et al. (2019) developed a AuNP modified titanium (Ti) metal substrate to detect cTnI based on DNA aptamer. AuNPs were deposited on Ti sheets by the potential-step deposition method. They immobilized the DNA aptamer using a self-assembled monolayer mechanism. The sensor obtained high sensitivity and specificity with the assistance of the AuNP-Ti layer and detected cTnI with the minimum detection limit of ca. 0.18 pM (Lopa et al., 2019).
Moreover, Adeel et al. (2019) modified the boron nitride nanosheets (BNNS) with AuNPs to detect MB in a low-cost, label-free and simple way (Figure 4A). BNNSs were synthesized via the hydrothermal method and were deposited on the fluorine-doped tin oxide (FTO) electrode. Subsequently, AuNPs were chemically deposited on the BNNS/FTO electrode. The AuNPs/BNNSs/FTO electrode was then used as a transducer to fix a thiol-functionalized DNA aptamer (Apt) via the Au-S covalent. When the MB bound to the sensor, [Fe(CN)6]3-/4- was used as a redox probe to monitor the oxidation current variation. The Apt/AuNPs/BNNSs/FTO sensor showed a high signal response for MB, with a detection limit of 34.6 ng/mL.
Phonklam et al. (2020) presented a molecularly imprinted polymer-based (MIP) EC sensor using a screen-printed carbon electrode (SPCE) to detect cTnT. The MIP sensor possessed an electrodeposited polymethylene blue (PMB) redox probe on SPCE, which was functionalized with multi-walled carbon nanotubes (MWCNTs). Also, the electropolymerized polyaniline was around the cTnT immobilized platform. The sensor response was stimulated by pulse voltammetry, wherein the concentration of cTnT was negatively associated with the PMB current. The linearity range of the sensor was between 0.10–8.0 pg/mL, with a detection limit of 0.040 pg/mL. Similarly, Vasantham et al. (2020) integrated MWCNT with Ab2 to detect cTnI via paper-based multi-frequency impedimetric transducers. The limit of detection was 0.05 ng/mL, and the response time was ∼1 min.
Singh et al. (2019) developed a microfluidic biosensor-integrated mesoporous nickel vanadate hollow-nanosphere modified chitosan (Ch-Ni3V2O8) to detect cTnI in patient samples. They synthesized chitosan-based (Ch) Ni3V2O8 hollow-nanospheres that could load abundant antibodies made possible by their hydroxy and amino clusters in the nanocomposite, their good adhesion capability, and their larger surface. Moreover, they amplified the electrochemical readouts because of tunable oxidation states of the Ch-Ni3V2O8 matrix. The microfluidic biosensor was fabricated using a three-electrode system, including a patterned gold (Au), silver (Ag/AgCl), and Ch-Ni3V2O8 electrodes on a glass substrate. A bare Au electrode represented as the counter electrode (CE). The Ch-Ni3V2O8 composite was added on the Au-coated substrate to capture cTnI antibodies and connect the microchannels. Ag/AgCl was deposited on the substrate using e-beam evaporation for the reference electrode (RE). This device offered 5 pg/mL limit detection of cTnI with high stability, good selectivity, and high reproducibility, and detected BNP, MB, cardiac troponin C (cTnC), and cTnT with specific antigens (Singh et al., 2019).
Shen et al. (2019) presented a label-free electrochemical immunosensor using a helical carbon nanotube (HCNTs)-supported aldehyde-functionalized ionic liquid (DIL). The DIL-HCNTs provided binding sites for Ab1, which simplified the sensor construction processes (Figure 4B) (Shen et al., 2019). The sandwich immunocomplexes influenced electron transfer on the electrode, thereby decreasing the peak current of differential pulse voltammetry (DPV). The signals corresponded to concentrations of cTnI.
Additionally, Sandil et al. (2019) immobilized cTnI (Ab1) on tungsten trioxide nanorods (WO3 NRs), which were deposited on indium tin oxide (ITO) using the electrophoretic deposition technique that worked as the electrode. The authors detected cTnI in a linear detection range of 0.01–10 ng/mL with high reproducibility (Sandil et al., 2019). Zhang et al. (2019) synthesized β-cyclodextrins-functionalized (CDs) 3D porous graphene-supported Pd@Au nanocubes (NCs) for cTnI detection. CDs were able to increase the dispersibility of the 3D-porous graphene and improve the capability of Ab2 capture. Besides, the electrochemical signal was improving given the Pd@Au NCs. In addition, the amino-functionalized microporous carbon sphere was functionalized using AuNPs and Th (AuNPs-FMCS-Th) to immobilize Ab1 effectively and accelerate the electron transfer process. The transfer was based on the reduction of H2O2 on the Th-modified electrode surface, which further amplified the signal response. The authors detected cTnI with a low detection limit of 33.3 fg/mL through the EC signal amplification labeling in the sandwich format (Zhang et al., 2019).
Similarly, Ma et al. (2019) utilized mesoporous Fe3O4-NH2 for loading cobalt phthalocyanine NPs (CoPc NPs) and captured Ab2 to form Fe3O4-Ab1 to detect cTnI. The aminated polystyrene microsphere (APSM) was used to cap on the mesoporous of Fe3O4-Ab1 by electrostatic interaction and presented as a molecular gate. Once the target cTnI was captured, CoPC NPs were released after APSM was separated. The CoPC NPs showed a superb catalytic performance that oxidized the cobalt element from Co (I) to Co (II) with the addition of H2O2. The reduction of current corresponded to concentrations of cTnI. This novel controlled release system-based EC immunoassay presented a broad linear range from 1.0 pg/mL to 100 ng/mL with a low detection limit of 0.39 pg/mL (Figure 4C) (Ma et al., 2019). Lv et al. (2019) functionalized the gold nanocube with graphene oxide (AuNC/GO) as the substrate to immobilize Ab1 via amino-Au affinity. To detect cTnI, the authors utilized Au@Ag core–shell nanocubes and nitrogen/sulfur doped GO as signal amplification labels to conjugate with Ab2 via Ag-N bonds. Once cTnI was captured, the catalyzed-oxidation of o-phenylenediamine (o-PD) with H2O2 was accelerated. The oxidation generated 2,3-diaminophenazine that gained in electrons and hydrogen and released an exaggerated current signal of DPV, which was used to electrochemical detect cTnI (Figure 4D) (Lv et al., 2019).
EC assay has shown advances in the sensitivity, but disadvantages remain. More specifically, the facility requires periodical calibration and care maintenance to guarantee accuracy, which is expensive and bothersome.
Surface-Enhanced Raman Scattering (SERS)
Surface-enhanced Raman scattering (SERS) immunoassay shows strong potential for CVD clinical diagnosis in view of their excellent multiplexing ability, high sensitivity, and large dynamic range (Huang et al., 2019). Typical SERS-based immunoassay uses substrates modified with Ab1 to capture targets, and the concentration of the targets is quantified by the SERS immunoprobe (Wang et al., 2017c). Nanomaterials have simplified the preparation and attachment of Raman labels thus have improved the sensitivity. For example, Fu et al. (2019) developed a capture probe/target/SERS nanotags platform to detect cTnI. They functionalized graphene oxide (GO) with AuNPs, which acted as both SERS nanotags and signal amplification carriers. The GO/AuNP complexes provided strong SERS enhancement ability and detected cTnI with a 5 pg/mL detection limit (Fu et al., 2019). Similarly, Cheng et al. (2019) loaded targets and polyclonal-antibody-conjugated Au@Ag core–shell nanoparticles in a gold-patterned chip that ran as a SERS active template for the ultrasensitive detection of cTnI and CK-MB. The limits of detection were 8.9 pg/mL and 9.7 pg/mL for cTnI and CK-MB, respectively.
While large surface area and outstanding physical properties of nanomaterials have facilitated sensitive SERS immunoassays, additional work is required on stabilizing the tag functionalization in SERS assays.
Surface Plasmon Resonance (SPR)
Surface plasmon resonance (SPR) biosensor measures the changes of the refractive index at the sensor surface. Its principle is based on charge-density oscillation that exists at the interface of two media, normally involving a metal (i.e., gold) and a dielectric. SPR has been used to detect proteins, DNA, and drugs (Mullett et al., 2000). SPR sensors are mainly classified as sensors with angular wavelength and intensity modulation (Dudak and Boyaci, 2009). Nanomaterials with plasmonic and optical properties, good distributing ability, strong photostability have amplified signals, hence, improved SPR sensitivity (Liu et al., 2013).
Recently, Chen et al. (2019) modified Au film with AuNPs and polydopamine (PDA), which ran as platforms for immobilizing Ab1 and SPR sensing. The films attracted the detection antibody on the PDA-coated Fe3O4 as the immune probe to detect cTnI (with a detection limit of 3.75 ng/mL) (Chen et al., 2019). The authors also introduced secondary antibody conjugated with multi-walled carbon nanotube (MWCNTs)-PDA-AgNPs to interact with cTnI exposed on the surface of probes, thus further amplifying the SPR response signal (Figure 5A).
Field Effect Transistor (FET)
Field effect transistor-based (FET) sensors have been applied in the biomedical analysis on grounds of their small size, high versatility, and low costs (Syedmoradi et al., 2019). FET-based sensors use an electric field to control the flow of current on platforms such as silicon nanowire and graphene (Kaisti, 2017).
Silicon nanoribbon fabricated biosensors are highly sensitive and uniform. However, they are expensive and complicated, requiring oxidation, photolithography, and wet etching. In contrast, semiconducting metal-oxide-based field-effect transistors (FET) biosensors show advantages, as simplicity and reliability. Photolithography-free shadow mask fabrication methods are also beneficial compared to silicon-based sensors. To give an example, Liu et al. developed a highly uniform, sensitive, and reusable In2O3 nanoribbon biosensor array using a lithography-free, scalable, and facile fabrication with high time efficiency (Figure 5B) (Liu Q. et al., 2016). The nanoribbons were formed through a first-layer shadow mask that was attached to a silicon substrate using In2O3 sputter-coating. The nanoribbons went through a metal electrode deposition process that was defined by a second-layer shadow mask. Two shadow masks were simply removed instead of being lifted off, as in the case in photolithography. Captured antibodies were fixed on the In2O3 surface using N-(3-dimethylaminopropyl)-N’-ethylcarbodiimide hydrochloride/N-hydroxysuccinimide (EDC/NHS) chemistry. A biotinylated secondary antibody was introduced to attach biomarkers, and its biotin tales were bounded to the streptavidin that attracted biotinylated urease later. Urea increased the pH of the solution, hence, causing the deprotonation of hydroxyl groups on the nanoribbon and lowering surface potential. Consequently, the conduction of the n-type nanoribbon FETs was decreased due to increased negative surface charges. They detected cTnI, CK-MB, and BNP down to 1 pg/mL, 0.1 ng/mL, and 10 pg/mL concentration range, respectively.
Enzyme-Linked Immunosorbent Assay (ELISA)
Enzyme-Linked Immunosorbent Assay (ELISA) is a commercialized method that identifies the concentration of targets through the color change of antigen-antibody reactions using an enzyme-linked conjugate and enzyme substrate. Even though ELISA shows advantages in reading results, it still requires more effort to improve sensitivity and accuracy (Aydin, 2015). Unique physical properties and biocompatibility of nanomaterials have greatly improved the performance of ELISA and below lateral flow assay (LFA). Nanofibers have the potential to reduce non-specific binding and improve binding efficiency due to their large surface area as an illustration. In addition, AuNPs conjugated with functional materials, such as HRP could amplify the detection signal in the assay (Wang W. et al., 2018).
Recently, Jiao et al. (2019) completed a multimodal ELISA diagnosis based on photothermal effect and the peroxidase-mimicking property in Au@Pt nanodendrites. The cTnI target was quantified using photothermal, colorimetric, and ratiometric fluorescent signals simultaneously.
Paper Based Lateral Flow Assay (LFA)
Lateral flow assay detects targets in a fast, simple, and cheap manner that has attracted much interests in recent years (Koczula and Gallotta, 2016). Lou et al. (2019a) functionalized the LFA with a multi-layer structure, including the BSA layer to increase biotinylation sites, a streptavidin layer loaded with a fluorescent dye, and an outermost layer on which the biotinylated antibody is bounded to the streptavidin. Due to the high loading efficiency of fluorescent molecules, the authors detected the cTnI within the range of 0.049–50 ng/mL (Lou et al., 2019a). Recently, Lou et al. (2019b) conjugated Ab2 onto polystyrene nanospheres at pH 5.8 for fast and sensitive immunodetection. At pH 5.8, the tail-on orientated antibodies (TP110) were conjugated on the carboxylated nanospheres (CNs) because of the charge distribution and the hydrophobic area of antibodies. As a result, the loading capacity of TP110 was increased, thus the authors detected cTnI with high sensitivity. The detailed procedure was illustrated in Figure 5C. Lim et al. (2019) utilized AuNPs conjugated anti-cTnT, silver-nanoparticles (AgNPs) conjugated anti-GPBB, and Gold urchin nanoparticles conjugated anti-CKMB as probes to detect multiplexed biomarkers simultaneously. The serum sample was loaded on the central sample pad and flowed through the NC membrane where anti-GPBB, anti-CK-MB, and anti-cTnT were immobilized on at three positions. Nanoparticles-conjugated detection antibodies were added on the NC membrane for color detection in the end. The detailed illustration was in Figure 5D (Lim et al., 2019).
Despite the convenience of ELISA and LFA in analyzing biomolecules, they have some drawbacks. ELISA suffers from complicated procedures, long assay duration (at least 2–3 h), and large sample consumptions. LFA requires labor-intensive preparations and is highly susceptible to false positives/negatives due to improper operations.
Nanotechnology-Based MOI
Nanomaterials with good bioavailability and versatility have increased the accuracy and specificity of clinical MOI applications thanks to improved resolution, signal amplification, and simple manipulation. Among other nanomaterials, nanoparticles are suitable for MOI since their mobilities in both internal and external vascular systems, high surface area to volume ratio, and imaging functionality. These advantages allow them to circulate through human bodies with low restrictions and produce functional imaging vehicles as contrast agents when they are applied in MOI settings, which leads to significantly improved diagnosis efficiency.
Nanoparticles can be used for RNA detection in intra-vascular systems because of their mobility. Injected or swallowed nanoparticles that are functionalized with MOI detectable molecules can circulate through the human body and target specific RNA for diagnosis. However, the size, shape, morphology, and density of functionalized nanoparticles should be explored carefully since the RNA detection requires nanoparticles entering and interacting with cells.
In addition, nanoparticles can work as nanoscale contrast agents by incorporating materials such as photoacoustic, fluorescent, radioactive, paramagnetic, superparamagnetic, electron-dense, light-scattering particles, and multimodal functional groups that are detectable by MOI.
The fluorescent material is a popular choice to conjugate with nanoparticles. For example, fluorescence labeled quantum dots (QDs) exhibit good performance in atherosclerotic plagues imaging (Jaffer et al., 2007). Popular radionuclides, including 18F, 64Cu, 68Ga, 124I, 86Y, have been conjugated with QDs, UCNPs, AuNPs, and NCs and have demonstrated good diagnostic functions (Saraste et al., 2009). For instance, radiolabeled nanoparticles play significant roles for atherosclerotic plagues under PET (Dobrucki and Sinusas, 2010). Radionuclides can be labeled either on the surface or encapsulated inside nanoparticles.
Additionally, superparamagnetic nanoparticles, like iron oxide (IO) nanoparticles and predominately magnetite (Fe2O3/Fe3O4), can improve the sensitivity of MRI by providing dark contrast to enhance the signal. For instance, MRI can detect thrombus (Chen and Wu, 2011), and the composition of plaques, including the fibrous cap and necrotic core, macrophage content, plaque neovascularization, intraplaque hemorrhage, and mural thrombus using superparamagnetic nanoparticles as contrasts (Avelar et al., 2017).
Also, AuNPs with good optical properties are good signal enhancers for photoacoustic tomography (PAT) (Taruttis et al., 2010). For example, Pan et al. (2014) successfully detected thrombus using gold nanobeacons under PAT. AuNPs can enhance the signal of coherence tomography (OCT) based on light-scattering as well.
Moreover, AuNPs were also widely used in CT as contrast agents. Hyafil et al. (2007) identified macrophages in atherosclerotic plagues using iodinated AuNPs facilitated CT. Kim et al. (2012) used polyethylene glycol (PEG)-coated AuNPs to improve the performance of CT scanning. They utilized PEG-coated GNPs as a contrast agent, in which the PEG-coating prevented antibiofouling and extended lifetime of AuNPs in the bloodstream. The PEG-coated GNPs obtained a better X-ray absorption coefficient and thus provided high-resolution images.
Conclusion and Future Perspective
Current clinical challenges of CVDs include generating straightforward, accurate diagnostic clinical decisions, and monitoring drug responses frequently. To overcome these difficulties, various platforms have been proposed. Among these platforms, CIAs have gained attraction since they can measure and evaluate the expression of biomarkers for the prediction and diagnosis of disease in a sensitive, rapid, cheap, and non-invasive manner. Additionally, MOI settings have emerged as promising techniques for CVD diagnosis thanks to their excellent imaging capabilities that facilitate physicians to make decisions. Even though significant advances in CIAs and MOI have been made regarding CVD diagnosis, the early-stage diagnosis is still challenging since symptoms of early-stage CVDs are vague, and the expression level of cardiac biomarkers at early-stage is relatively low for detection.
Therefore, novel platforms with improved sensitivity and specificity are required. As summarized in this review, nanotechnology has greatly contributed to the developments of MOI and CIA on account of its specific physicochemical properties. By virtue of their excellent biocompatibility, nanomaterials can conjugate with various biomolecules because their excellent biocompatibility. These functional biomolecules were able to increase the sensitivity and specificity of diagnostic platforms. For example, AuNP-conjugated capture antibody can reduce non-specific bindings, thereby increasing the capture specificity and eliminating background noises in various CIAs. Besides, fluorescence lumiphore conjugated nanomaterials can work as enhancers to amplify the detective signals in ELISA, or as contrast agents in MOI. In addition, except for functionalized with other biomolecules, nanomaterial itself can serve as a signal enhancer. This is made possible by their unique optical, electrical and plasmonic properties, silica NPs can quench photocurrent effectively in PEC biosensors as an example. Moreover, nanomaterials with a large surface area (e.g., nanocubes) can improve the loading efficiency of biomolecules to increase the sensitivity of CIAs. To better elucidate CIAs in CVD diagnosis, the lasted outcomes of nanotechnology assisted CIAs (e.g., ECL) was introduced, with comparison to the sensitivity and detection range of cardiac targets among these assays. We also reviewed the clinical applications of nanoparticles in MOI settings. In this regard, we believe strongly bridging clinical platforms and nanotechnology is necessary for directing future research plans.
In this review, we have highlighted the advantages of CIAs. They are non-invasive, cheap, sensitivity, and convenient. Its repeat-sampling ability also makes it ideal for long-term diagnosis and prognosis. However, the CIA testing still faces challenges. An important concern is the sensitivity and specificity of the biomarker. Previous researchers have shown that a single marker may be insufficient, lack sensitivity and specificity for accurate CVD diagnosis. It is unrealistic to provide clear diagnosis results using only one biomarker owing to the complexity, heterogeneity and diversity of pathogenesis in different populations. Additionally, biomarkers may be regulated differently during the development of pathologies. Consequently, even though we can diagnosis some clinical subjects who have high risks for certain diseases using biomarkers (e.g., cTnI for AMI), we have insufficient information on the progression and states of the diseases (Madhurantakam et al., 2018). To solve this problem, multiplexed biomarker panels are critical. The multiplexed analysis of various biomarkers can establish correlations (or scores) with high specificities and predictive values, as a result, can improve the accuracy of diagnostic decisions. Hence, the fabrication of CIAs should focus on multiplexed analysis in the future. In addition, current findings on biomarkers are based on relatively small samples, which may possess large variations (Sayed et al., 2014). Most of the studies only focused on the correlation between biomarker expression level and single disease. The pathological significance behind the biomarker expression level changing is not addressed yet. As such, large-scale and systematic clinical studies are needed to recognize and better understand the mechanisms of biomarkers. Most importantly, combination with advanced analytic tools (e.g., machine learning) that is capable of developing objective and automatic algorithms to analyze large-scale and high-dimensional-multiplexed data should be highlighted in future studies, which are supposed to greatly improve the efficiency and accuracy of diagnosis.
Author Contributions
ZY and JZ coordinated this project. CS and HX wrote this manuscript. CS and HX collected and summarized the literatures. YM edited the figures in this manuscript and revised this manuscript.
Conflict of Interest
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
The reviewer MK declared a shared affiliation, with no collaboration, with one of the authors, YM, to the handling Editor at the time of review.
References
- Abdorahim M., Rabiee M., Alhosseini S. N., Tahriri M., Yazdanpanah S., Alavi S. H., et al. (2016). Nanomaterials-based electrochemical immunosensors for cardiac troponin recognition: an illustrated review. TrAC Trends Anal. Chem. 82 337–347. 10.1016/j.trac.2016.06.015 [DOI] [Google Scholar]
- Adeel M., Rahman M. M., Lee J. J. (2019). Label-free aptasensor for the detection of cardiac biomarker myoglobin based on gold nanoparticles decorated boron nitride nanosheets. Biosens. Bioelectron. 126 143–150. 10.1016/j.bios.2018.10.060 [DOI] [PubMed] [Google Scholar]
- Adhikari J., Keasberry N. A., Mahadi A. H., Yoshikawa H., Tamiya E., Ahmed M. U. (2019). An ultra-sensitive label-free electrochemiluminescence CKMB immunosensor using a novel nanocomposite-modified printed electrode. RSC Adv. 9 34283–34292. 10.1039/c9ra05016g [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ali M., Sajid M., Khalid M. A. U., Kim S. W., Lim J. H., Huh D., et al. (2020). A fluorescent lateral flow biosensor for the quantitative detection of Vaspin using upconverting nanoparticles. Spectrochim. Acta Part A Mol. Biomol. Spectrosc. 226:117610. 10.1016/j.saa.2019.117610 [DOI] [PubMed] [Google Scholar]
- Anderon L. (2005). Candidate-based proteomics in the search for biomarkers of cardiovascular disease. J. Physiol. 563(Pt 1) 23–60. 10.1113/jphysiol.2004.080473 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Anderson T. J., Grégoire J., Hegele R. A., Couture P., Mancini G. B. J., McPherson R., et al. (2013). 2012 update of the canadian cardiovascular society guidelines for the diagnosis and treatment of dyslipidemia for the prevention of cardiovascular disease in the adult. Can. J. Cardiol. 29 151–167. 10.1016/j.cjca.2012.11.032 [DOI] [PubMed] [Google Scholar]
- Apple F. S., Falahati A., Paulsen P. R., Miller E. A., Sharkey S. W. (1997). Improved detection of minor ischemic myocardial injury with measurement of serum cardiac troponin I. Clin. Chem. 43 2047–2051. 10.1093/clinchem/43.11.2047 [DOI] [PubMed] [Google Scholar]
- Article E. (2018). CT SCAN. Diagn. Radiol. Radiother. 1 162–169. 10.22328/2079-5343-2018-9-1-162-169 [DOI] [Google Scholar]
- Avelar E., Strickland C. R., Rosito G. (2017). Role of imaging in cardio-oncology. Curr. Treat. Options Cardiovasc. Med. 19:46. 10.1007/s11936-017-0546-2 [DOI] [PubMed] [Google Scholar]
- Aydin S. (2015). A short history, principles, and types of ELISA, and our laboratory experience with peptide/protein analyses using ELISA. Peptides 72 4–15. 10.1016/j.peptides.2015.04.012 [DOI] [PubMed] [Google Scholar]
- Bang C., Batkai S., Dangwal S., Gupta S. K., Foinquinos A., Holzmann A., et al. (2014). Cardiac fibroblast-derived microRNA passenger strand-enriched exosomes mediate cardiomyocyte hypertrophy. J. Clin. Invest. 124 2136–2146. 10.1172/JCI70577 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Chakrabarti S., Wu X., Yang Z., Wu L., Yong S. L., Zhang C., et al. (2013). MOG1 rescues defective trafficking of nav1.5 mutations in brugada syndrome and sick sinus syndrome. Circ. Arrhythmia Electrophysiol. 6 392–401. 10.1161/CIRCEP.111.000206 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Chen F., Wu Q., Song D., Wang X., Ma P., Sun Y. (2019). Fe 3 O 4 @PDA immune probe-based signal amplification in surface plasmon resonance (SPR) biosensing of human cardiac troponin I. Colloids Surf. B Biointerfaces. 177 105–111. 10.1016/j.colsurfb.2019.01.053 [DOI] [PubMed] [Google Scholar]
- Chen I. Y., Wu J. C. (2011). Cardiovascular molecular imaging: focus on clinical translation. Circulation 123 425–443. 10.1161/CIRCULATIONAHA.109.916338 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Chen Y., Song Y., Huang J., Qu M., Zhang Y., Geng J., et al. (2017). Increased circulating exosomal miRNA-223 is associated with acute ischemic stroke. Front. Neurol. 8:57. 10.3389/fneur.2017.00057 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Chen Z., Zhang A., Wang X., Zhu J., Fan Y., Yu H., et al. (2017). The advances of carbon nanotubes in cancer diagnostics and therapeutics. J. Nanomater. 2017:3418932 10.1155/2017/3418932 [DOI] [Google Scholar]
- Cheng Y., Wang X., Yang J., Duan X., Yao Y., Shi X., et al. (2012). A translational study of urine miRNAs in acute myocardial infarction. J. Mol. Cell. Cardiol. 53 668–676. 10.1016/j.yjmcc.2012.08.010 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Cheng Z., Wang R., Xing Y., Zhao L., Choo J., Yu F. (2019). SERS-based immunoassay using gold-patterned array chips for rapid and sensitive detection of dual cardiac biomarkers. Analyst 144 6533–6540. 10.1039/c9an01260e [DOI] [PubMed] [Google Scholar]
- Christenson E., Christenson R. H. (2013). The role of cardiac biomarkers in the diagnosis and management of patients presenting with suspected acute coronary syndrome. Ann. Lab. Med. 33 309–318. 10.3343/alm.2013.33.5.309 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Corsten M. F., Dennert R., Jochems S., Kuznetsova T., Devaux Y., Hofstra L., et al. (2010). Circulating MicroRNA-208b and MicroRNA-499 reflect myocardial damage in cardiovascular disease. Circ. Cardiovasc. Genet. 3 499–506. 10.1161/CIRCGENETICS.110.957415 [DOI] [PubMed] [Google Scholar]
- D’Agostino R. B., Vasan R. S., Pencina M. J., Wolf P. A., Cobain M., Massaro J. M., et al. (2008). General cardiovascular risk profile for use in primary care: the Framingham heart study. Circulation. 117 743–753. 10.1161/CIRCULATIONAHA.107.699579 [DOI] [PubMed] [Google Scholar]
- de Jong O. G., Verhaar M. C., Chen Y., Vader P., Gremmels H., Posthuma G., et al. (2012). Cellular stress conditions are reflected in the protein and RNA content of endothelial cell-derived exosomes. J. Extracell. Vesicles 1:18396. 10.3402/jev.v1i0.18396 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Devaux Y., Vausort M., McCann G. P., Kelly D., Collignon O., Ng L. L., et al. (2013). A panel of 4 microRNAs Facilitates the prediction of left ventricular contractility after acute myocardial infarction. PLoS One 8:e70644. 10.1371/journal.pone.0070644 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Dobrucki L. W., Sinusas A. J. (2010). PET and SPECT in cardiovascular molecular imaging. Nat. Rev. Cardiol. 7 38–47. 10.1038/nrcardio.2009.201 [DOI] [PubMed] [Google Scholar]
- Dong W., Mo X., Wang Y., Lei Q., Li H. (2020). Photoelectrochemical immunosensor based on ZnIn2S4/Bi2Se3 nanocomposite for the determination of cardiac troponin I. Anal. Lett. 10.1080/00032719.2020.1721003 [DOI] [Google Scholar]
- Dong X., Zhao G., Li X., Miao J. C., Fang J., Wei Q., et al. (2019). Electrochemiluminescence immunoassay for the N-terminal pro-B-type natriuretic peptide based on resonance energy transfer between a self-enhanced luminophore composed of silver nanocubes on gold nanoparticles and a metal-organic framework of type MIL-125. Microchim. Acta 186:811. 10.1007/s00604-019-3969-5 [DOI] [PubMed] [Google Scholar]
- Dudak F. C., Boyaci I. H. (2009). Rapid and label-free bacteria detection by surface plasmon resonance (SPR) biosensors. Biotechnol. J. 4 1003–1011. 10.1002/biot.200800316 [DOI] [PubMed] [Google Scholar]
- Durrani-Kolarik S., Pool C. A., Gray A., Heyob K. M., Cismowski M. J., Pryhuber G., et al. (2017). miR-29b supplementation decreases expression of matrix proteins and improves alveolarization in mice exposed to maternal inflammation and neonatal hyperoxia. Am. J. Physiol. Lung Cell. Mol. Physiol. 313 L339–L349. 10.1152/ajplung.00273.2016 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ellis K. L., Cameron V. A., Troughton R. W., Frampton C. M., Ellmers L. J., Richards A. M. (2013). Circulating microRNAs as candidate markers to distinguish heart failure in breathless patients. Eur. J. Heart Fail. 15 1138–1147. 10.1093/eurjhf/hft078 [DOI] [PubMed] [Google Scholar]
- Fan C., Tang Y., Zhao M., Lou X., Pretorius D., Menasche P., et al. (2020a). CHIR99021 and fibroblast growth factor 1 enhance the regenerative potency of human cardiac muscle patch after myocardial infarction in mice. J. Mol. Cell. Cardiol. 141 1–10. 10.1016/j.yjmcc.2020.03.003 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Fan C., Zhang E., Joshi J., Yang J., Zhang J., Zhu W. (2020b). Utilization of human induced pluripotent stem cells for cardiac repair. Front. Cell Dev. Biol. 8:36. 10.3389/fcell.2020.00036 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Feng Q. M., Shen Y. Z., Li M. X., Zhang Z. L., Zhao W., Xu J. J., et al. (2016). Dual-wavelength electrochemiluminescence ratiometry based on resonance energy transfer between au nanoparticles functionalized g-C3N4 Nanosheet and Ru(bpy)32+ for microRNA Detection. Anal. Chem. 88 937–944. 10.1021/acs.analchem.5b03670 [DOI] [PubMed] [Google Scholar]
- Fesmire F. M., Percy R. F., Bardoner J. B., Wharton D. R., Calhoun F. B. (1998). Usefulness of automated serial 12-lead ECG monitoring during the initial emergency department evaluation of patients with chest pain. Ann. Emerg. Med. 31 3–11. 10.1016/S0196-0644(98)70274-4 [DOI] [PubMed] [Google Scholar]
- Friese R. S., Altshuler A. E., Zhang K., Miramontes-Gonzalez J. P., Hightower C. M., Jirout M. L., et al. (2013). MicroRNA-22 and promoter motif polymorphisms at the Chga locus in genetic hypertension: functional andtherapeutic implications forgeneexpressionand the pathogenesis of hypertension. Hum. Mol. Genet. 22 3624–3640. 10.1093/hmg/ddt213 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Fu X., Wang Y., Liu Y., Liu H., Fu L., Wen J., et al. (2019). A graphene oxide/gold nanoparticle-based amplification method for SERS immunoassay of cardiac troponin I. Analyst 144 1582–1589. 10.1039/c8an02022a [DOI] [PubMed] [Google Scholar]
- Gan C. S., Wang C. W., Tan K. S. (2012). Circulatory microRNA-145 expression is increased in cerebral ischemia. Genet. Mol. Res. 11 147–152. 10.4238/2012.January.27.1 [DOI] [PubMed] [Google Scholar]
- Gao C., Xue J., Zhang L., Zhao P., Cui K., Ge S., et al. (2019). Paper based modification-free photoelectrochemical sensing platform with single-crystalline aloe like TiO 2 as electron transporting material for cTnI detection. Biosens. Bioelectron. 131 17–23. 10.1016/j.bios.2019.01.038 [DOI] [PubMed] [Google Scholar]
- Gidlöf O., Andersson P., Van Der Pals J., Götberg M., Erlinge D. (2011). Cardiospecific microRNA plasma levels correlate with troponin and cardiac function in patients with ST elevation myocardial infarction, are selectively dependent on renal elimination, and can be detected in urine samples. Cardiology. 118 217–226. 10.1159/000328869 [DOI] [PubMed] [Google Scholar]
- Golberg D., Bando Y., Huang Y., Terao T., Mitome M., Tang C., et al. (2010). Boron nitride nanotubes and nanosheets. ACS Nano 4 2979–2993. 10.1021/nn1006495 [DOI] [PubMed] [Google Scholar]
- Goren Y., Kushnir M., Zafrir B., Tabak S., Lewis B. S., Amir O. (2012). Serum levels of microRNAs in patients with heart failure. Eur. J. Heart Fail. 14 147–154. 10.1093/eurjhf/hfr155 [DOI] [PubMed] [Google Scholar]
- Govindappa P. K., Patil M., Garikipati V. N. S., Verma S. K., Saheera S., Narasimhan G., et al. (2020). Targeting exosome-associated human antigen R attenuates fibrosis and inflammation in diabetic heart. FASEB J. 34 2238–2251. 10.1096/fj.201901995R [DOI] [PMC free article] [PubMed] [Google Scholar]
- Guo X., Zong L., Jiao Y., Han Y., Zhang X., Xu J., et al. (2019). Signal-enhanced detection of multiplexed cardiac biomarkers by a paper-based fluorogenic immunodevice integrated with zinc oxide nanowires. Anal. Chem. 91 9300–9307. 10.1021/acs.analchem.9b02557 [DOI] [PubMed] [Google Scholar]
- Haase M., Schäfer H. (2011). Upconverting nanoparticles. Angew. Chem. Int. Ed Engl. 50 5808–5829. 10.1002/anie.201005159 [DOI] [PubMed] [Google Scholar]
- Han G. R., Kim M. G. (2019). Design, synthesis, and evaluation of gold nanoparticle-antibody-horseradish peroxidase conjugates for highly sensitive chemiluminescence immunoassay (hs-CLIA). Biotechnol. Bioprocess. Eng. 24 206–214. 10.1007/s12257-018-0369-3 [DOI] [Google Scholar]
- Hao N., Li X. L., Zhang H. R., Xu J. J., Chen H. Y. (2014). A highly sensitive ratiometric electrochemiluminescent biosensor for microRNA detection based on cyclic enzyme amplification and resonance energy transfer. Chem. Commun. 50 14828–14830. 10.1039/c4cc06801g [DOI] [PubMed] [Google Scholar]
- Hashemi R. H., Bradley W. G., Lisanti C. J. (2012). MRI: The Basics. Philadelphia, PA: Lippincott Williams & Wilkins. [Google Scholar]
- Ho K. J. (2018). “Cardiovascular diseases,” in Nutritional Aspects of Aging, Vol. 2 ed. Chen L. H. (Boca Raton, FL: CRC Press; ), 10.1201/9781351075145 [DOI] [Google Scholar]
- Homola J., Yee S. S., Gauglitz G. (1999). Surface plasmon resonance sensors: review. Sens. Actuat. B Chem. 54 3–15. 10.1016/S0925-4005(98)00321-9 [DOI] [Google Scholar]
- Huang Z., Zhang A., Zhang Q., Cui D. (2019). Nanomaterial-based SERS sensing technology for biomedical application. J. Mater. Chem. B 7 3755–3774. 10.1039/c9tb00666d 32113545 [DOI] [Google Scholar]
- Hur J., Kim Y. J., Lee H. J., Nam J. E., Ha J. W., Heo J. H., et al. (2011). Dual-enhanced cardiac CT for detection of left atrial appendage thrombus in patients with stroke?: a prospective comparison study with transesophageal echocardiography. Stroke 42 2471–2477. 10.1161/STROKEAHA.110.611293 [DOI] [PubMed] [Google Scholar]
- Hur J., Kim Y. J., Lee H. J., Nam J. E., Hong J., Kim H. Y., et al. (2012). Cardioembolic stroke: dual-energy cardiac CT for differentiation of left atrial appendage thrombus and circulatory stasis. Radiology 263 688–695. 10.1148/radiol.12111691 [DOI] [PubMed] [Google Scholar]
- Hutton B. F. (2014). The origins of SPECT and SPECT/CT. Eur. J. Nucl. Med. Mol. Imaging. 41(Suppl. 1) S3–S16. 10.1007/s00259-013-2606-5 [DOI] [PubMed] [Google Scholar]
- Hyafil F., Cornily J. C., Feig J. E., Gordon R., Vucic E., Amirbekian V., et al. (2007). Noninvasive detection of macrophages using a nanoparticulate contrast agent for computed tomography. Nat. Med. 13 636–641. 10.1038/nm1571 [DOI] [PubMed] [Google Scholar]
- Jaffer F. A., Libby P., Weissleder R. (2007). Molecular imaging of cardiovascular disease. Circulation 116 1052–1061. 10.1161/CIRCULATIONAHA.106.647164 [DOI] [PubMed] [Google Scholar]
- Ji T., Xu X., Wang X., Zhou Q., Ding W., Chen B., et al. (2019). Point of care upconversion nanoparticles-based lateral flow assay quantifying myoglobin in clinical human blood samples. Sens. Actuat. B Chem. 281 309–316. 10.1016/j.snb.2018.11.074 [DOI] [Google Scholar]
- Ji X., Takahashi R., Hiura Y., Hirokawa G., Fukushima Y., Iwai N. (2009). Plasma miR-208 as a biomarker of myocardial injury. Clin. Chem. 55 1944–1949. 10.1373/clinchem.2009.125310 [DOI] [PubMed] [Google Scholar]
- Jiao L., Zhang L., Du W., Li H., Yang D., Zhu C. (2019). Au@Pt nanodendrites enhanced multimodal enzyme-linked immunosorbent assay. Nanoscale 11 8798–8802. 10.1039/c8nr08741e [DOI] [PubMed] [Google Scholar]
- Jo H., Gu H., Jeon W., Youn H., Her J., Kim S. K., et al. (2015). Electrochemical aptasensor of cardiac Troponin I for the early diagnosis of acute myocardial infarction. Anal. Chem. 87 9869–9875. 10.1021/acs.analchem.5b02312 [DOI] [PubMed] [Google Scholar]
- Johnson S. (2012). “Nanotechnology,” in Encyclopedia of Applied Ethics, ed. Chadwick R. (San Diego, CA: Academic Press; ). [Google Scholar]
- Joshi J., Rubart M., Zhu W. (2020). Optogenetics: background, methodological advances and potential applications for cardiovascular research and medicine. Front. Bioeng. Biotechnol. 7:466. 10.3389/fbioe.2019.00466 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kaisti M. (2017). Detection principles of biological and chemical FET sensors. Biosens. Bioelectron. 98 437–448. 10.1016/j.bios.2017.07.010 [DOI] [PubMed] [Google Scholar]
- Kim S. H., Kim E. M., Lee C. M., Kim D. W., Lim S. T., Sohn M. H., et al. (2012). Synthesis of PEG-iodine-capped gold nanoparticles and their contrast enhancement in in vitro and in vivo for X-ray/CT. J. Nanomater. 2012:504026 10.1155/2012/504026 [DOI] [Google Scholar]
- Kirkpatrick I. D. C., Kroeker M. A., Greenberg H. M. (2003). Biphasic CT with mesenteric CT angiography in the evaluation of acute mesenteric ischemia: initial experience. Radiology 229 91–98. 10.1148/radiol.2291020991 [DOI] [PubMed] [Google Scholar]
- Koczula K. M., Gallotta A. (2016). Lateral flow assays. Essays Biochem. 60 111–120. 10.1042/EBC20150012 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kong J., Franklin N. R., Zhou C., Chapline M. G., Peng S., Cho K., et al. (2000). Nanotube molecular wires as chemical sensors. Science 287 622–625. 10.1126/science.287.5453.622 [DOI] [PubMed] [Google Scholar]
- Korff S., Katus H. A., Giannitsis E. (2006). Differential diagnosis of elevated troponins. Heart 92 987–993. 10.1136/hrt.2005.071282 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kuriyama R., Tanaka Y., Akiyama S., Sato Y. (2011). “Effect of electric double layer on near-wall ph in microfluidic device measured by nano-LIF,” in Proceedings of the 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011, Seattle, WA. [Google Scholar]
- Laflamme M. A., Sebastian M. M., Buetow B. S. (2012). 10 - Cardiovascular. Comp. Anat. Histol. 135–153. 10.1016/B978-0-12-381361-9.00010-X [DOI] [Google Scholar]
- Lakshmanakumar M., Nesakumar N., Sethuraman S., Rajan K. S., Krishnan U. M., Rayappan J. B. B. (2019). Functionalized graphene quantum dot interfaced electrochemical detection of cardiac Troponin I: an antibody free approach. Sci. Rep. 9:17348. 10.1038/s41598-019-53979-5 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Li C., Wang L. V. (2009). Photoacoustic tomography and sensing in biomedicine. Phys. Med. Biol. 54 R59–R97. 10.1088/0031-9155/54/19/R01 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Li S., Zhu J., Zhang W., Chen Y., Zhang K., Popescu L. M., et al. (2011). Signature microRNA expression profile of essential hypertension and its novel link to human cytomegalovirus infection. Circulation 124 175–184. 10.1161/CIRCULATIONAHA.110.012237 [DOI] [PubMed] [Google Scholar]
- Li Y. Q., Zhang M. F., Wen H. Y., Hu C. L., Liu R., Wei H. Y., et al. (2013). Comparing the diagnostic values of circulating microRNAs and cardiac troponin T in patients with acute myocardial infarction. Clinics 68 75–80. 10.6061/clinics/2013(01)OA12 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Libby P. (2002). Inflammation in atherosclerosis. Nature 1 297–329. 10.1038/nature01323 [DOI] [PubMed] [Google Scholar]
- Lichtenstein A. H., Matthan N. R. (2007). “Cardiovascular disease,” in Optimizing Women’s Health through Nutrition, eds Thompson L. U., Ward W. E. (Boca Raton, FL: CRC Press; ). [Google Scholar]
- Lim W. Y., Thevarajah T. M., Goh B. T., Khor S. M. (2019). Paper microfluidic device for early diagnosis and prognosis of acute myocardial infarction via quantitative multiplex cardiac biomarker detection. Biosens. Bioelectron. 128 176–185. 10.1016/j.bios.2018.12.049 [DOI] [PubMed] [Google Scholar]
- Liu G., Qi M., Zhang Y., Cao C., Goldys E. M. (2016). Nanocomposites of gold nanoparticles and graphene oxide towards an stable label-free electrochemical immunosensor for detection of cardiac marker troponin-I. Anal. Chim. Acta 909 1–8. 10.1016/j.aca.2015.12.023 [DOI] [PubMed] [Google Scholar]
- Liu P., Yang X., Sun S., Wang Q., Wang K., Huang J., et al. (2013). Enzyme-free colorimetric detection of DNA by using gold nanoparticles and hybridization chain reaction amplification. Anal. Chem. 85 7689–7695. 10.1021/ac4001157 [DOI] [PubMed] [Google Scholar]
- Liu Q., Aroonyadet N., Song Y., Wang X., Cao X., Liu Y., et al. (2016). Highly sensitive and quick detection of acute myocardial infarction biomarkers using In2O3 nanoribbon biosensors fabricated using shadow masks. ACS Nano 10 10117–10125. 10.1021/acsnano.6b05171 [DOI] [PubMed] [Google Scholar]
- Liu T., Yu J., Deng M., Yin Y., Zhang H., Luo K., et al. (2017). CDK4/6-dependent activation of DUB3 regulates cancer metastasis through SNAIL1. Nat. Commun. 8:13923. 10.1038/ncomms13923 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Liu Y., Ma Y., Zhang J., Yuan Y., Wang J. (2019). Exosomes: a novel therapeutic agent for cartilage and bone tissue regeneration. Dose Response 17:1559325819892702. 10.1177/1559325819892702 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Long G., Wang F., Duan Q., Chen F., Yang S., Gong W., et al. (2012a). Human circulating microRNA-1 and microRNA-126 as potential novel indicators for acute myocardial infarction. Int. J. Biol. Sci. 8 811–818. 10.7150/ijbs.4439 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Long G., Wang F., Duan Q., Yang S., Chen F., Gong W., et al. (2012b). Circulating miR-30a, miR-195 and let-7b associated with acute myocardial infarction. PLoS One 7:e50926. 10.1371/journal.pone.0050926 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lopa N. S., Rahman M. M., Ahmed F., Ryu T., Sutradhar S. C., Lei J., et al. (2019). Simple, low-cost, sensitive and label-free aptasensor for the detection of cardiac troponin I based on a gold nanoparticles modified titanium foil. Biosens. Bioelectron. 136 381–388. 10.1016/j.bios.2018.11.012 [DOI] [PubMed] [Google Scholar]
- Lou D., Fan L., Ji Y., Gu N., Zhang Y. (2019a). A signal amplifying fluorescent nanoprobe and lateral flow assay for ultrasensitive detection of cardiac biomarker Troponin I. Anal. Methods 11 3506–3513. 10.1039/c9ay01039d [DOI] [Google Scholar]
- Lou D., Ji L., Fan L., Ji Y., Gu N., Zhang Y. (2019b). Antibody-oriented strategy and mechanism for the preparation of fluorescent nanoprobes for fast and sensitive immunodetection. Langmuir 35 4860–4867. 10.1021/acs.langmuir.9b00150 [DOI] [PubMed] [Google Scholar]
- Lu S., Wang S., Zhao J., Sun J., Yang X. (2017). Fluorescence light-up biosensor for MicroRNA based on the distance-dependent photoinduced electron transfer. Anal. Chem. 89 8429–8436. 10.1021/acs.analchem.7b01900 [DOI] [PubMed] [Google Scholar]
- Lv H., Zhang X., Li Y., Ren Y., Zhang C., Wang P., et al. (2019). An electrochemical sandwich immunosensor for cardiac troponin I by using nitrogen/sulfur co-doped graphene oxide modified with Au@Ag nanocubes as amplifiers. Microchim. Acta 186:416. 10.1007/s00604-019-3526-2 [DOI] [PubMed] [Google Scholar]
- Ma N., Zhang T., Yan T., Kuang X., Wang H., Wu D., et al. (2019). Novel electrochemical immunosensor for sensitive monitoring of cardiac troponin I using antigen–response cargo released from mesoporous Fe3O4. Biosens. Bioelectron. 143:111608. 10.1016/j.bios.2019.111608 [DOI] [PubMed] [Google Scholar]
- Madhurantakam S., Babu K. J., Rayappan J. B. B., Krishnan U. M. (2018). Nanotechnology-based electrochemical detection strategies for hypertension markers. Biosens. Bioelectron. 116 67–80. 10.1016/j.bios.2018.05.034 [DOI] [PubMed] [Google Scholar]
- Marfella R., Di Filippo C., Potenza N., Sardu C., Rizzo M. R., Siniscalchi M., et al. (2013). CirculatingmicroRNA changes in heart failure patients treated with cardiac resynchronization therapy: responders vs. non-responders. Eur. J. Heart Fail. 15 1277–1288. 10.1093/eurjhf/hft088 [DOI] [PubMed] [Google Scholar]
- Matsumoto S., Sakata Y., Suna S., Nakatani D., Usami M., Hara M., et al. (2013). Circulating p53-responsive MicroRNAs are predictive indicators of heart failure after acute myocardial infarction. Circ. Res. 113 322–326. 10.1161/CIRCRESAHA.113.301209 [DOI] [PubMed] [Google Scholar]
- McRobbie D. W., Moore E. A., Graves M. J. (2017). MRI From Picture to Proton. Cambridge: Cambridge University Press; 10.2214/ajr.182.3.1820592 [DOI] [Google Scholar]
- Miao L., Jiao L., Tang Q., Li H., Zhang L., Wei Q. (2019). A nanozyme-linked immunosorbent assay for dual-modal colorimetric and ratiometric fluorescent detection of cardiac troponin I. Sens. Actuat. B Chem. 288 60–64. 10.1016/j.snb.2019.02.111 [DOI] [Google Scholar]
- Mullett W. M., Lai E. P. C., Yeung J. M. (2000). Surface plasmon resonance-based immunoassays. Methods 22 77–91. 10.1006/meth.2000.1039 [DOI] [PubMed] [Google Scholar]
- Oerlemans M. I. F. J., Mosterd A., Dekker M. S., de Vrey E. A., van Mil A., Pasterkamp G., et al. (2012). Early assessment of acute coronary syndromes in the emergency department: the potential diagnostic value of circulating microRNAs. EMBO Mol. Med. 4 1176–1185. 10.1002/emmm.201201749 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Osborn E. A., Jaffer F. A. (2013). The advancing clinical impact of molecular imaging in CVD. JACC Cardiovasc. Imaging 6 1327–1341. 10.1016/j.jcmg.2013.09.014 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pan D., Schirra C. O., Wickline S. A., Lanza G. M. (2014). Multicolor computed tomographic molecular imaging with noncrystalline high-metal-density nanobeacons. Contrast Media Mol. Imaging 9 13–25. 10.1002/cmmi.1571 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Phonklam K., Wannapob R., Sriwimol W., Thavarungkul P., Phairatana T. (2020). A novel molecularly imprinted polymer PMB/MWCNTs sensor for highly-sensitive cardiac troponin T detection. Sens. Actuat. B Chem. 308:127630 10.1016/j.snb.2019.127630 [DOI] [Google Scholar]
- Pykett I. L., Buonanno F. S., Brady T. J., Kistler J. P. (1983). True three-dimensional nuclear magnetic resonance neuro-imaging in ischemic stroke: correlation of nmr, x-ray ct and pathology. Stroke 14 173–177. 10.1161/01.STR.14.2.173 [DOI] [PubMed] [Google Scholar]
- Qureshi A., Gurbuz Y., Niazi J. H. (2012). Biosensors for cardiac biomarkers detection: a review. Sens. Actuat. B Chem. 171–172 62–76. 10.1016/j.snb.2012.05.077 [DOI] [Google Scholar]
- Rehman S. A., Khurshid Z., Niazi F. H., Naseem M., Waddani H., Al Sahibzada H. A., et al. (2017). Role of salivary biomarkers in detection of cardiovascular diseases (CVD). Proteomes 5 4–9. 10.3390/proteomes5030021 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Richter M. M. (2004). Electrochemiluminescence (ECL). Chem. Rev. 104 3003–3036. 10.1021/cr020373d [DOI] [PubMed] [Google Scholar]
- Sandil D., Sharma S. C., Puri N. K. (2019). Protein-functionalized WO3 nanorods-based impedimetric platform for sensitive and label-free detection of a cardiac biomarker. J. Mater. Res. 34 1331–1340. 10.1557/jmr.2018.481 [DOI] [Google Scholar]
- Saraste A., Nekolla S. G., Schwaiger M. (2009). Cardiovascular molecular imaging: an overview. Cardiovasc. Res. 83 643–652. 10.1093/cvr/cvp209 [DOI] [PubMed] [Google Scholar]
- Sayed A. S. M., Xia K., Salma U., Yang T., Peng J. (2014). Diagnosis, prognosis and therapeutic role of circulating miRNAs in cardiovascular diseases. Heart Lung Circ. 23 503–510. 10.1016/j.hlc.2014.01.001 [DOI] [PubMed] [Google Scholar]
- Shan B., Chai P., Zhang Z. (2013). “Positron emission tomography,” in Advanced Topics in Science and Technology in China, eds Bailey D. L., Townsend D. W., Valk P. E., Maisey M. N. (Berlin: Springer; ). [Google Scholar]
- Shen Q., Liu M., Lü Y., Zhang D., Cheng Z., Liu Y., et al. (2019). Label-free electrochemical immunosensor based on a functionalized ionic liquid and helical carbon nanotubes for the determination of cardiac Troponin I. ACS Omega 4 11888–11892. 10.1021/acsomega.9b01152 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Singh N., Rai P., Ali M. A., Kumar R., Sharma A., Malhotra B. D., et al. (2019). A hollow-nanosphere-based microfluidic biosensor for biomonitoring of cardiac troponin i. J. Mater. Chem. B 7 3826–3839. 10.1039/c9tb00126c [DOI] [Google Scholar]
- Strianese M., Staiano M., Ruggiero G., Labella T., Pellecchia C., D’Auria S. (2012). Fluorescence-based biosensors. Methods Mol. Biol. 875 193–216. 10.1007/978-1-61779-806-1_9 [DOI] [PubMed] [Google Scholar]
- Sun J., Zhuang J., Shi J., Kormakov S., Liu Y., Yang Z., et al. (2019). Highly elastic and ultrathin nanopaper-based nanocomposites with superior electric and thermal characteristics. J. Mater. Sci. 54 8436–8449. 10.1007/s10853-019-03472-1 [DOI] [Google Scholar]
- Sun Y., Kang C., Zhang A., Liu F., Hu J., Zhong X., et al. (2016). Co-delivery of dual-drugs with nanoparticle to overcome multidrug resistance. Eur. J. Biomed. Res. 2 12–18. 10.18088/ejbmr.2.2.2016 [DOI] [Google Scholar]
- Syedmoradi L., Ahmadi A., Norton M. L., Omidfar K. (2019). A review on nanomaterial-based field effect transistor technology for biomarker detection. Microchim. Acta 186:739. 10.1007/s00604-019-3850-6 [DOI] [PubMed] [Google Scholar]
- Tan G. R., Wang M., Hsu C. Y., Chen N., Zhang Y. (2016). Small upconverting fluorescent nanoparticles for biosensing and bioimaging. Adv. Opt. Mater. 4 984–997. 10.1002/adom.201600141 [DOI] [Google Scholar]
- Tan X., Zhang L., Tang Q., Zheng G., Li H. (2019). Ratiometric fluorescent immunoassay for the cardiac troponin-I using carbon dots and palladium-iridium nanocubes with peroxidase-mimicking activity. Microchim. Acta. 186:280. 10.1007/s00604-019-3375-z [DOI] [PubMed] [Google Scholar]
- Taruttis A., Herzog E., Razansky D., Ntziachristos V. (2010). Real-time imaging of cardiovascular dynamics and circulating gold nanorods with multispectral optoacoustic tomography. Opt. Express. 18 19592–19602. 10.1364/oe.18.019592 [DOI] [PubMed] [Google Scholar]
- Tijsen A. J., Creemers E. E., Moerland P. D., De Windt L. J., Van Der Wal A. C., Kok W. E., et al. (2010). MiR423-5p as a circulating biomarker for heart failure. Circ. Res. 106 1035–1039. 10.1161/CIRCRESAHA.110.218297 [DOI] [PubMed] [Google Scholar]
- Tsai P. C., Liao Y. C., Wang Y. S., Lin H. F., Lin R. T., Juo S. H. H. (2013). Serum microrna-21 and microrna-221 as potential biomarkers for cerebrovascular disease. J. Vasc. Res. 50 346–354. 10.1159/000351767 [DOI] [PubMed] [Google Scholar]
- Van Schooneveld M. M., Cormode D. P., Koole R., Van Wijngaarden J. T., Calcagno C., Skajaa T., et al. (2010). A fluorescent, paramagnetic and PEGylated gold/silica nanoparticle for MRI, CT and fluorescence imaging. Contrast Media Mol. Imaging 5 231–236. 10.1002/cmmi.376 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Vasantham S., Alhans R., Singhal C., Nagabooshanam S., Nissar S., Basu T., et al. (2020). Paper based point of care immunosensor for the impedimetric detection of cardiac troponin I biomarker. Biomed. Microdevices 22:6. 10.1007/s10544-019-0463-0 [DOI] [PubMed] [Google Scholar]
- Walters N., Nguyen L. T. H., Zhang J., Shankaran A., Reátegui E. (2019). Extracellular vesicles as mediators of in vitro neutrophil swarming on a large-scale microparticle array. Lab Chip 19 2874–2884. 10.1039/c9lc00483a [DOI] [PubMed] [Google Scholar]
- Wang G. K., Zhu J. Q., Zhang J. T., Li Q., Li Y., He J., et al. (2010). Circulating microRNA: a novel potential biomarker for early diagnosis of acute myocardial infarction in humans. Eur. Heart J. 31 659–666. 10.1093/eurheartj/ehq013 [DOI] [PubMed] [Google Scholar]
- Wang S., Zhao Y., Wang M., Li H., Saqib M., Ge C., et al. (2019). Enhancing luminol electrochemiluminescence by combined use of cobalt-based metal organic frameworks and silver nanoparticles and its application in ultrasensitive detection of cardiac Troponin I. Anal. Chem. 91 3048–3054. 10.1021/acs.analchem.8b05443 [DOI] [PubMed] [Google Scholar]
- Wang W., Zou Y., Yan J., Liu J., Chen H., Li S., et al. (2018). Ultrasensitive colorimetric immunoassay for hCG detection based on dual catalysis of Au@Pt core–shell nanoparticle functionalized by horseradish peroxidase. Spectrochim. Acta Part A Mol. Biomol. Spectrosc. 193 102–108. 10.1016/j.saa.2017.12.014 [DOI] [PubMed] [Google Scholar]
- Wang X., Kwak K. J., Yang Z., Zhang A., Zhang X., Sullivan R., et al. (2018). Extracellular mRNA detected by molecular beacons in tethered lipoplex nanoparticles for diagnosis of human hepatocellular carcinoma. PLoS One 13:e0198552. 10.1371/journal.pone.0198552 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wang X., Yang Z., Tian H., Li Y., Li M., Zhao W., et al. (2017a). Circulating MIC-1/GDF15 is a complementary screening biomarker with CEA and correlates with liver metastasis and poor survival in colorectal cancer. Oncotarget 8 24892–24901. 10.18632/oncotarget.15279 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wang X., Zhi X., Yang Z., Tian H., Li Y., Li M., et al. (2017b). A novel serum based biomarker panel has complementary ability to preclude presence of early lung cancer for low dose CT (LDCT). Oncotarget 8 45345–45355. 10.18632/oncotarget.17477 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wang Z., Zong S., Wu L., Zhu D., Cui Y. (2017c). SERS-activated platforms for immunoassay: probes, encoding methods, and applications. Chem. Rev. 117 7910–7963. 10.1021/acs.chemrev.7b00027 [DOI] [PubMed] [Google Scholar]
- Xia J., Yao J., Wang L. V. (2014). Photoacoustic tomography: principles and advances. Prog. Electromagn. Res. 147 1–22. 10.2528/PIER14032303 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Xue T. Y., Mei L. P., Xu Y. T., Liu Y. L., Fan G. C., Li H. Y., et al. (2019). Nanoporous semiconductor electrode captures the quantum dots: toward ultrasensitive signal-on liposomal photoelectrochemical immunoassay. Anal. Chem. 91 3795–3799. 10.1021/acs.analchem.9b00170 [DOI] [PubMed] [Google Scholar]
- Yang Z., Ma Y., Zhao H., Yuan Y., Kim B. Y. S. (2020a). Nanotechnology platforms for cancer immunotherapy. Wiley Interdiscip. Rev. Nanomed. Nanobiotechnol. 12 1–28. 10.1002/wnan.1590 [DOI] [PubMed] [Google Scholar]
- Yang Z., Shi J., Xie J., Wang Y., Sun J., Liu T., et al. (2020b). Large-scale generation of functional mRNA-encapsulating exosomes via cellular nanoporation. Nat. Biomed. Eng. 4 69–83. 10.1038/s41551-019-0485-1 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Yang Z., Sun W., Hu K. (2009). Adenosine A1 receptors selectively target protein kinase C isoforms to the caveolin-rich plasma membrane in cardiac myocytes. Biochim. Biophys. Acta Mol. Cell Res. 1793 1868–1875. 10.1016/j.bbamcr.2009.10.007 [DOI] [PubMed] [Google Scholar]
- Yang Z., Sun W., Hu K. (2012). Molecular mechanism underlying adenosine receptor-mediated mitochondrial targeting of protein kinase C. Biochim. Biophys. Acta Mol. Cell Res. 1823 950–958. 10.1016/j.bbamcr.2011.12.012 [DOI] [PubMed] [Google Scholar]
- Yang Z., Xie J., Zhu J., Kang C., Chiang C., Wang X., et al. (2016). Functional exosome-mimic for delivery of siRNA to cancer: in vitro and in vivo evaluation. J. Control. Release 243 160–171. 10.1016/j.jconrel.2016.10.008 [DOI] [PubMed] [Google Scholar]
- Yeh H. C., Sharma J., Han J. J., Martinez J. S., Werner J. H. (2010). A DNA-silver nanocluster probe that fluoresces upon hybridization. Nano Lett. 10 3106–3110. 10.1021/nl101773c [DOI] [PubMed] [Google Scholar]
- Yu H., Yang Z., Pan S., Yang Y., Tian J., Wang L., et al. (2015). Hypoxic preconditioning promotes the translocation of protein kinase C ε binding with caveolin-3 at cell membrane not mitochondrial in rat heart. Cell Cycle 14 3557–3565. 10.1080/15384101.2015.1084446 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Yu X., Deng L., Wang D., Li N., Chen X., Cheng X., et al. (2012). Mechanism of TNF-α autocrine effects in hypoxic cardiomyocytes: initiated by hypoxia inducible factor 1α, presented by exosomes. J. Mol. Cell. Cardiol. 53 848–857. 10.1016/j.yjmcc.2012.10.002 [DOI] [PubMed] [Google Scholar]
- Zamani P., Fereydouni N., Butler A. E., Navashenaq J. G., Sahebkar A. (2019). The therapeutic and diagnostic role of exosomes in cardiovascular diseases. Trends Cardiovasc. Med. 29 313–323. 10.1016/j.tcm.2018.10.010 [DOI] [PubMed] [Google Scholar]
- Zeng L., Liu J., Wang Y., Wang L., Weng S., Tang Y., et al. (2011). MicroRNA-210 as a novel blood biomarker in acute cerebral ischemia. Front. Biosci. 3:1265–1272. 10.2741/e330 [DOI] [PubMed] [Google Scholar]
- Zhang J., Nie H., Wu Z., Yang Z., Zhang L., Xu X., et al. (2014). Self-catalytic growth of unmodified gold nanoparticles as conductive bridges mediated gap-electrical signal transduction for DNA hybridization detection. Anal. Chem. 86 1178–1185. 10.1021/ac4032675 [DOI] [PubMed] [Google Scholar]
- Zhang X., Lv H., Li Y., Zhang C., Wang P., Liu Q., et al. (2019). Ultrasensitive sandwich-type immunosensor for cardiac troponin i based on enhanced electrocatalytic reduction of H 2 O 2 using β-cyclodextrins functionalized 3D porous graphene-supported Pd@Au nanocubes. J. Mater. Chem. B 7 1460–1468. 10.1039/c8tb03362e [DOI] [PubMed] [Google Scholar]
- Zhao W. W., Xu J. J., Chen H. Y. (2014). Photoelectrochemical DNA biosensors. Chem. Rev. 114 7421–7441. 10.1021/cr500100j [DOI] [PubMed] [Google Scholar]
- Zhao W. W., Yu P. P., Shan Y., Wang J., Xu J. J., Chen H. Y. (2012). Exciton-plasmon interactions between CdS quantum dots and Ag nanoparticles in photoelectrochemical system and its biosensing application. Anal. Chem. 84 5892–5897. 10.1021/ac300127s [DOI] [PubMed] [Google Scholar]
- Zhou C., Yang Z., Teng L. (2014). Nanomedicine based on nucleic acids: pharmacokinetic and pharmacodynamic perspectives. Curr. Pharm. Biotechnol. 15 829–838. 10.2174/1389201015666141020155620 [DOI] [PubMed] [Google Scholar]
- Zhu D., Liu W., Zhao D., Hao Q., Li J., Huang J., et al. (2017). Label-free electrochemical sensing platform for MicroRNA-21 detection using thionine and gold nanoparticles co-functionalized MoS2 nanosheet. ACS Appl. Mater. Interfaces 9 35597–35603. 10.1021/acsami.7b11385 [DOI] [PubMed] [Google Scholar]
- Zhu L., Ye J., Yan M., Zhu Q., Wang S., Huang J., et al. (2019). Electrochemiluminescence immunosensor based on Au nanocluster and hybridization chain reaction signal amplification for ultrasensitive detection of cardiac Troponin I. ACS Sens. 4 2778–2785. 10.1021/acssensors.9b01369 [DOI] [PubMed] [Google Scholar]
- Zou B., Cheng H., Tu Y. (2019). An electrochemiluminescence immunosensor for myoglobin using an indium tin oxide glass electrode modified with gold nanoparticles and platinum nanowires. Microchim. Acta 186:598. 10.1007/s00604-019-3703-3 [DOI] [PubMed] [Google Scholar]