High-Resolution Photonic Force Microscopy Based on Sharp Nanofabricated Tips

Rudy Desgarceaux †,, Zhanna Santybayeva , Eliana Battistella , Ashley L Nord , Catherine Braun-Breton , Manouk Abkarian , Onofrio M Maragò §, Benoit Charlot ∥,*, Francesco Pedaci †,*
PMCID: PMC7292031  PMID: 32369369

Abstract

graphic file with name nl0c00729_0005.jpg

Although near-field imaging techniques reach sub-nanometer resolution on rigid samples, it remains extremely challenging to image soft interfaces, such as biological membranes, due to the deformations induced by the probe. In photonic force microscopy, optical tweezers are used to manipulate and measure the scanning probe, allowing imaging of soft materials without force-induced artifacts. However, the size of the optically trapped probe still limits the maximum resolution. Here, we show a novel and simple nanofabrication protocol to massively produce optically trappable quartz particles which mimic the sharp tips of atomic force microscopy. Imaging rigid nanostructures with our tips, we resolve features smaller than 80 nm. Scanning the membrane of living malaria-infected red blood cells reveals, with no visible artifacts, submicron features termed knobs, related to the parasite activity. The use of nanoengineered particles in photonic force microscopy opens the way to imaging soft samples at high resolution.

Keywords: photonic force microscopy, optical tweezers, sharp nanocylinders, red blood cells, malaria


In photonic force microscopy (PhFM), the laser trap raster scans the sample and the induced displacement of the trapped particle from its equilibrium position is measured by fast interferometry.18 Other than providing sub-piconewton/nanometer stiffness, optically trapping the probe decouples it from the instrument, potentially allowing low-force scanning within confined volumes not accessible by other techniques.9 As in atomic force microscopy (AFM), measurements of the axial displacement of the probe in PhFM (signal Sz) reach the nanometer resolution. Recently, an improved version of the PhFM6 has achieved resolutions beyond the diffraction limit in the transverse directions (signals Sx and Sy) using ∼100–200 nm beads as scanning probes. When trapping a spherical particle, reducing its size unfortunately reduces also the signal-to-noise ratio obtained; therefore, other strategies are required to increase the lateral resolution. In order to control the applied optical force and to increase the resolution, different particle geometries have been used in different configurations.1014 In particular, the behavior of elongated particles trapped in optical tweezers (OT) has been studied experimentally and theoretically due to their potential use as scanning probes.1519 Second harmonic generation of optically trapped particles has also attracted interest for its potential in scanning microscopy, local spectroscopy, and thermometry.16,20,21 However, the resolution of PhFM still remains limited to hundreds of nanometers in two of the three dimensions, and the PhFM lags behind the AFM mainly because sharp tips equivalent to those used in AFM have yet to be developed.

We have developed a novel nanofabrication protocol (sketched in Figure 1a), wherein we can produce optically trappable particles (60 × 106 per batch) which mimic the sharp tips of AFM. Importantly, to allow stable trapping and to maximize the optical signals from the OT, the probe is designed as a large micron-sized truncated cone, holding a sharp feature (of 35 nm radius of curvature in Figure 1b) in the center of its top surface.

Figure 1.

Figure 1

Tip fabrication and optical setup. (a) Microfabrication process. Cylindrical particles are generated by laser interference lithography, etching a quartz substrate where a 800 nm thick SiO2 layer is deposited. A tuned acid thinning by hydrofluoric acid produces sharp tips in the SiO2 layer. The particles are then cleaved mechanically off the substrate. (b) Scanning electron microscope image of cleaved particles, where the contrast of one tip has been enhanced for clarity. The radius of curvature of the tip is 35 nm. (c) Schematic cartoon of the optical trap holding the particle and scanning the surface of the sample with the sharp tip. (d) Schematic optical setup. L/2, half-wave plate; PBS, polarizer; AOM, acousto-optical modulator; NPBS, nonpolarizing beam splitter; Exp, beam expander; T1:1, one to one telescope; Obj, objective; Cond, condenser; PD, photodiode (to acquire Sz); PSD, position-sensitive detector (to acquire Sx,y); IRCCD, infrared CCD camera; VisCCD, visible CCD camera.

The simplicity of the nanofabrication protocol relies mainly on the use of laser interference lithography (LIL)22 (a cost-effective, parallel, and reliable technique which we describe in detail in ref (23)) to write the pattern that produces the particles. The particle geometry is produced by two serial etching processes which follow the LIL exposure: a first anisotropic reactive ion etching to produce the cylindrical geometry, followed by an isotropic hydrofluoric acid (HF) wet etch step to produce the tips on a top deposited SiO2 layer. Once obtained, the particles are mechanically cleaved off the substrate, collected, and stored in liquid. With scanning electron microscopy imaging, we find that 30% of the collected particles maintain their tip. The details of the nanofabrication protocol are described in the Supporting Information.

The core material chosen is quartz, a crystal whose birefringence is instrumental in PhFM. Birefringent cylindrical particles have been developed by different techniques in the context of optical single-molecule manipulation.2328 Due to the torque imposed by radiation pressure, the main axis of the trapped particle remains parallel to the laser propagation direction. Also, due to the torque imposed by the laser linear polarization on the birefringent medium, the x-cut quartz particle cannot rotate about its geometrical axis (the particle can rotate about its main axis if the laser polarization is circular or if the linear polarization is set in rotation).29,30 This constrains all the degrees of freedom (x, y, z and two angles, Figure 1c) of the trapped particle. Moreover, the chemical stability of the crystal prevents the formation of reactive molecules, as observed in trapped semiconductor and metallic nanoparticles.31 Our OT setup is shown in Figure 1d and is described in detail in the Supporting Information. Briefly, a stabilized infrared laser beam of 20–60 mW power is focused by a 1.2 NA microscope objective into a flow cell containing the sample to scan. The forward-scattering detection consists of a position-sensitive detector (PSD) to acquire the transverse displacement of the trapped particle (signals Sx and Sy) and of a separate photodiode with reduced numerical aperture32 to detect the axial displacement (Sz signal). In this way, the transverse and axial resolution can be maximized independently.

Despite its complex geometry, the particle in the trap behaves not too differently from the standard spherical dielectric beads commonly used in OT. We characterize and quantify its behavior in Figure 2 by analyzing its overdamped Langevin dynamics (as inertia does not play a role at a low Reynolds number). In Figure 2a, we perform a distance-displacement measurement: the signals Sz,x,y are recorded while the trap position slowly scans the axial direction and contacts the rigid substrate surface. The resulting z-displacement of the tip within the trap can be approximated by a linear curve for displacements up to 400 nm. At the same time, the Sx and Sy signals remain constant, indicating that the particle x, y position is only slightly perturbed when exploring the extreme axial region of the optical potential. In order to calibrate the instrument, we extract the sensitivity β (0.94 mV/nm) from the linear region of the z-displacement curve in Figure 2a, by which one can map the signals from volts to physical distance (e.g., see the inset of Figure 2b). Fitting the power spectrum shown in Figure 2b with a Lorentzian function,34 we obtain the trap stiffness kz (3 fN/nm) and the particle drag γz (6 × 10–6 pN s/nm). To test the calibration further, we compare the resulting drag coefficient γz with the theoretical value γ obtainable for microscopic cylinders35 (see Supporting Information section 2), which we find in the range γ = (6–9) × 10–6 pN s/nm, validating our experimental value. Also, if we consider the theoretical value of the drag coefficient γ for a cylinder translating in the plane x, y we can calibrate the transverse dimensions of the OT, as well. This allows us to obtain images of the sample from the three displacement signals: Sz, Sx, and Sy.

Figure 2.

Figure 2

Characterization of the trapped particle. (a) Indentation measurement. The signals Sz,x,y are recorded while the optical trap is moved along z. The particle starts interacting with the flat glass surface at z = 0. The Sz signal is linear in the region highlighted in orange. Here, the tip faces the surface (see Figure 3a). (b) PSD of the signals Sz,x,y acquired from a particle trapped in the liquid bulk. The dashed lines correspond to Lorentzian fits to the data. The inset shows the signal Sz in nanometers, together with its probability density (blue histogram), fit by a Gaussian distribution (orange line). (c) Allan deviation for a particle trapped in bulk (blue points) and in contact to the surface (orange points). The black dashed line corresponds to the fit of the analytical expression33 for a particle in a harmonic potential. When the particle is in contact with the glass surface, drift becomes relevant for measurements integrating for more than 1 s. (d) Auto- and cross-correlation functions of the signal Sz,x,y for a particle trapped in the liquid bulk. The dashed lines correspond to single-exponential fits.

In Figure 2c, we trace the Allan deviation36,37 of Sz, which quantifies the accuracy of the measured mean value of the signal as a function of the integration time used. When measured in bulk, the Allan deviation can be fit by an analytical expression for a spherical particle in a harmonic potential.33 The fit provides a trap stiffness kz (4 fN/nm) compatible with the previous results (whereas the drag γz = 11 × 10–6 pN nm/s is far from the value obtained above because of the hypothesis of spherical geometry). The Allan deviation peak indicates that the particle requires ∼10 ms to explore the trap volume and that ∼4 s of integration is required to reach 1 nm accuracy. When measured with the particle in contact with the surface, the Allan deviation indicates that drift in our setup starts to deteriorate the z-accuracy for integration times longer than 1 s. In the following, when imaging the sample surface with these particles, as a compromise between z-measurement accuracy and imaging time, we fix the time spent on each pixel to 80 ms, expecting an accuracy in z of few nanometers (see Supporting Information Figure S5 for the implementation of drift correction).

Additionally, the auto- and cross-correlations of the signals carry interesting information about the linear and angular fluctuations of the elongated particle.3840 After correcting for a small crosstalk between the signals Sx and Sy (see Supporting Information section 2), we find that both the autocorrelations, Cii(τ) = ⟨Si(t)Sii(t + τ)⟩ (i = x, y, z), and the transverse cross-correlation, Cxy(τ), can be fit by a single exponential (Figure 2c). The values of the exponential rates of Cxx, Cyy, and Cxy (corresponding to ωi = kii for Cii (i = x, y) and to ΩΘ = kΘΘ for Cxy, where Θ indicates the tilt angle; see Figure 1c) are found within 3% relative error. Considering the theoretical value for the angular drag coefficient of a cylinder with the dimensions compatible with our particle (γΘ = 8.8 pN nm s; see Supporting Information section 4), we can estimate from the exponential fit of Cxx and Cyy (Ω = 4530 s–1) the value of the angular stiffness (kΘ = 4 × 104 pN nm; see Supporting Information section 3). The tilt angular fluctuations of the trapped particle can be estimated from Inline graphic. In conclusion, these results show that the particle remains stably trapped vertically in the laser focus, and that its axial position can be accurately measured by the signal Sz.

To validate our approach, we employ the nanofabricated tips to image structures on a hard substrate, which can be reliably imaged by conventional AFM for comparison. To this end, we etched the glass coverslip surface masked by randomly adhered 100 nm polystyrene beads. We find that the scattering due to the sample is negligible with respect to that from the trapped particle, due to its micrometer-scale size. Therefore, we do not implement here the correction successfully proposed by Friedrich et al. for more optically thick samples.6 The results are shown in Figure 3. First, for each particle trapped, we need to assess whether the tip faces the sample. We have found that this can be done easily and systematically by running a set of z-displacement measurements (Figure 3a), where, between each measurement, the laser trap is briefly blocked to let the particle reorient. The curves corresponding to the two configurations (tip up, tip down) are well recognizable from their shape and relative position.

Figure 3.

Figure 3

AFM and PhFM imaging of rigid samples. (a) z position-displacement curves for the two possible particle orientations. When the tip faces the surface (orange points), the contact point appears before (∼400 nm) than when the tip is in the opposite direction (blue points). The shape and relative values (in volts) of the two curves differ and allow systematic recognition of the tip orientation. The dashed lines correspond to a fit to a piece-wise polynomial function. (b) Image of 100 nm random features on glass obtained with the tip not facing the sample. (c) AFM image and (d) PhFM image (with tip facing the sample) of the same region. (e,g) AFM and (f,h) PhFM images of the same regions. Details of 80 nm can be resolved (see Supporting Information Figure S6). The color bars of (d,f,h) are the same. All the scans cover an area of 1 × 1 μm2.

We then record the signals Sz,x,y while scanning the sample surface sequentially at discrete positions spaced by 10 nm, which correspond to the position of each pixel. The images in Figure 3b,d correspond to the image of the same region obtained with the two tip configurations: the details of the sample appear only when the tip faces the sample. The image of the same region obtained by AFM (Figure 3c) confirms the one obtained by PhFM (Figure 3d). Two more comparisons between images of the same sample obtained by AFM and PhFM are shown in Figure 3e,f and Figure 3g,h and indicate that features of at least 80 nm (see Supporting Information Figure S6) can be well resolved with the nanofabricated tips by PhFM. Given the stiffness of the optical trap (kz = 3 fN/nm), the maximum force applied by the tip on the sample remains lower than 0.4 pN. Interestingly, the image obtained from the transverse tip displacement (Sx, Sy) highlights the borders of the objects scanned (Supporting Information Figure S3).

To demonstrate the potential of the technique in scanning intact living cells (without artificial hardening the sample, as routinely done in AFM to produce a sufficient probe displacement), we now image the external membrane of intact red blood cells infected by the malaria parasite. When Plasmodium falciparum infects a red blood cell, it exports newly expressed proteins (such as PfEMP1 and KHARP) to the host cell membrane, altering its otherwise smooth topography. As a result, small features of about 100 nm, termed knobs, appear on the surface, stiffening the membrane and causing increased cell adherence and eventually vascular flow nuisances41 (Figure 4a). The infected red blood cells are immobilized on a poly-l-lysine (PLL)-coated glass coverslip, which also applies tension to the membrane. The cells are otherwise not treated biochemically.

Figure 4.

Figure 4

PhFM of the membrane of living malaria-infected red blood cells presenting knobs on its surface. (a) Optical (left) and SEM (right, kindly provided by Laurence Berry, UMR5235 Un. Montpellier) image of an infected red blood presenting knobs on its surface. A region scanned by PhFM is shown in the optical image. (b) Axial position-displacement curves obtained on the hard glass surface and on the cell membrane. The linear fits after contact are shown by dashed lines. Inset: corresponding indentation curves, where the curve corresponding to the glass surface is set vertical. (c) Image obtained from the axial displacement signal Sz in a first scan of an infected cell and (d) its high-pass filtered version. (e) Image obtained in a subsequent scan in the region highlighted in red and (f) its filtered version. In (d,f), the same protrusions ascribable to knobs are marked by circles, showing that their position is the same in the two scans. (g–i) Scan on a different infected cell, where the images are obtained from the signals Sz, Sx, Sy as indicated and high-pass filtered. Despite the limited axial resolution in Sz (g), the presence of the knobs is retrieved in the transverse signals (h,i).

In Figure 4b, we first show the results of membrane indentation measurements. The signal Sz is shown as a function of the axial position of the optical trap, approaching both the cell membrane and the rigid glass surface. Taking as a reference the curve obtained on glass, the inset shows that the membrane is indented by a maximum of 100 nm when the tip axial displacement is 300 nm. The calibration provides here an axial stiffness of kz = 1.5 fN/nm; therefore, the maximum force applied on the membrane by the tip is 0.45 pN. These measurements have been corrected by subtracting a background due to scattering, as shown in Supporting Information Figure S9. We then scan a 2 × 2 μm2 region of the cell far from the location of the optically dense hemozoin (a byproduct of hemoglobin digestion) and of the parasite (Figure 4a). When the low frequencies are removed by 2D polynomial subtraction from the original image (Figure 4c and Supporting Information Figure S8), small protrusions of ∼100 nm diameter and ∼20 nm height become clearly visible (Figure 4d). A subsequent scan of the region highlighted in red in Figure 4c,d confirms the positions and dimensions of these structures (∼150 nm × 40 nm, Figure 4e,f and Supporting Information Figure S8), which are compatible with knobs observed by electron microscopy and AFM on dead cells.4143 Images of similarly immobilized noninfected red blood cells show a smoother topography, where such structures are absent, as expected (Supporting Information Figure S10). In Figure 4g–i, we show the scan of a different infected live cell, where the axial resolution (Figure 4g) is barely sufficient to resolve the knobs even after image filtering. However, information about the presence and positions of the knobs can also be retrieved from the transverse signals Sx, Sy (Figure 4h,i), which reflect the lateral shift of the particle in the trap due to the sample topography (encountering small features along its trajectory, the probe is shifted both axially and laterally). Although this information is currently qualitative, this shows the rich information easily obtainable by PhFM (similar to lateral force microscopy in AFM44), the exploitation of which will be explored in future studies.

In conclusion, we have shown a new and simple nanofabrication protocol to massively produce optically trappable particles with sharp tips, and by characterizing their behavior in the trap, we have shown that they are well suited for scanning imaging. Employing the tips in PhFM, we obtain images of rigid substrates with resolution below 80 nm, which compare well with those obtained by AFM. The potential of PhFM in scanning soft materials while applying sub-piconewton force is shown in imaging the 150 nm × 40 nm knobs on the membrane of red blood cells infected by P. falciparum. Images are obtained from living cells, with a maximum force of a fraction of a piconewton, introducing no visible artifacts. Other scanning techniques mainly require chemical fixation to rigidify the sample (therefore killing the cells) and need to apply minimum forces of tens to hundreds of piconewton to obtain a sufficient probe deflection and a good signal-to-noise ratio in the image (a notable alternative is scanning ion conductance microscopy45). In our implementation of PhFM, we find that a critical factor is the passivation of the probe (currently we use incubation in bovine serum albumin). Aspecific binding of the probe to the sample often terminates the scan, and the low force of the optical trap is not always sufficient to free the particle. Novel strategies have to be explored in this regard. The speed of imaging depends on the time required for the probe to accurately sample each pixel (a 100 × 100 pixel image requires 13 min). To decrease this characteristic time (equal to γ/k), the trap stiffness k can be increased via the laser power, but this is not always compatible with delicate samples. Alternatively, smaller particles could be engineered from higher index materials in order to decrease the drag while keeping high stiffness. A good candidate is TiO2.28 Interestingly, using a birefringent material (such as quartz or TiO2) also allows for torque manipulation.24,30,46 Despite the fact that our particles are not absorbing and that the absorption of water in the near-infrared is low,47 heating effects48 might be detrimental for the behavior of biological material under a PhFM scan. Thus, it is generally important to keep the trapping power at the sample below 50 mW (as in our case) to minimize thermal heating around the trapping region. As local heating of the sample during the scan should be minimized, it is interesting to note that novel methods such as laser refrigeration can be achieved with nanocrystals in resonant conditions.49,50 The photonic force microscope and optical tweezers are versatile and multifunctional instruments, which allow mechanical and dynamical measurements, together with manipulation at the micro- and nanoscale. Our results open the way to new PhFM development for high-resolution imaging.

Acknowledgments

This paper is dedicated to the memory of our colleague Jelle van der Does. We are grateful to to Luca Costa, Pierre Emmanuel Milhiet, and Felix Rico for fruitful input and discussions, to Didier Portran and Viviana Claveria for their help in sample and cell preparations, to Frederic Pichot for the microfabrication, Roland Teissier for the development of the LIL setup, Michel Ramonda for the AFM images, and Laurence Berry for the infected red blood cell image. We acknowledge funding from the European Research Council under the European Union’s Seventh Framework Programme (FP/2007-2013)/ERC Grant Agreement No. 306475. The CBS is a member of the France-BioImaging (FBI) and the French Infrastructure for Integrated Structural Biology (FRISBI), 2 national infrastructures supported by the French National Research Agency (ANR-10-INBS-04-01 and ANR-10-INBS-05, respectively).

Supporting Information Available

The Supporting Information is available free of charge at https://pubs.acs.org/doi/10.1021/acs.nanolett.0c00729.

  • Methods, corrections, correlation analysis theory, theoretical drag of microscopic cylinders, image calibration and reconstruction (PDF)

Author Contributions

R.D. and Z.S. contributed equally.

The authors declare no competing financial interest.

Supplementary Material

nl0c00729_si_001.pdf (2.4MB, pdf)

References

  1. Ghislain L. P.; Webb W. W. Scanning-force microscope based on an optical trap. Opt. Lett. 1993, 18, 1678–1680. 10.1364/OL.18.001678. [DOI] [PubMed] [Google Scholar]
  2. Florin E.-L.; Pralle A.; Heinrich Hörber J.; Stelzer E. H. Photonic force microscope based on optical tweezers and two-photon excitation for biological applications. J. Struct. Biol. 1997, 119, 202–211. 10.1006/jsbi.1997.3880. [DOI] [PubMed] [Google Scholar]
  3. Friese M.; Truscott A.; Rubinsztein-Dunlop H.; Heckenberg N. Three-dimensional imaging with optical tweezers. Appl. Opt. 1999, 38, 6597–6603. 10.1364/AO.38.006597. [DOI] [PubMed] [Google Scholar]
  4. Tischer C.; et al. Three-dimensional thermal noise imaging. Appl. Phys. Lett. 2001, 79, 3878–3880. 10.1063/1.1423404. [DOI] [Google Scholar]
  5. Maragò O.; Gucciardi P.; Jones P.. Scanning Probe Microscopy in Nanoscience and Nanotechnology; Springer, 2010; pp 23–56. [Google Scholar]
  6. Friedrich L.; Rohrbach A. Surface imaging beyond the diffraction limit with optically trapped spheres. Nat. Nanotechnol. 2015, 10, 1064. 10.1038/nnano.2015.202. [DOI] [PubMed] [Google Scholar]
  7. Jones P. H.; Maragò O. M.; Volpe G.. Optical Tweezers: Principles and Applications; Cambridge University Press, 2015. [Google Scholar]
  8. Bartsch T. F.; Kochanczyk M. D.; Lissek E. N.; Lange J. R.; Florin E.-L. Nanoscopic imaging of thick heterogeneous soft-matter structures in aqueous solution. Nat. Commun. 2016, 7, 12729. 10.1038/ncomms12729. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Rohrbach A.; Tischer C.; Neumayer D.; Florin E.-L.; Stelzer E. H. Trapping and tracking a local probe with a photonic force microscope. Rev. Sci. Instrum. 2004, 75, 2197–2210. 10.1063/1.1753097. [DOI] [Google Scholar]
  10. Phillips D. B.; et al. An optically actuated surface scanning probe. Opt. Express 2012, 20, 29679–29693. 10.1364/OE.20.029679. [DOI] [PubMed] [Google Scholar]
  11. Simpson S. H.; Phillips D.; Carberry D.; Hanna S. Bespoke optical springs and passive force clamps from shaped dielectric particles. J. Quant. Spectrosc. Radiat. Transfer 2013, 126, 91–98. 10.1016/j.jqsrt.2012.10.014. [DOI] [Google Scholar]
  12. Phillips D.; et al. Shape-induced force fields in optical trapping. Nat. Photonics 2014, 8, 400. 10.1038/nphoton.2014.74. [DOI] [Google Scholar]
  13. Phillips D. B.; et al. Surface imaging using holographic optical tweezers. Nanotechnology 2011, 22, 285503. 10.1088/0957-4484/22/28/285503. [DOI] [PubMed] [Google Scholar]
  14. Olof S.; et al. Measuring nanoscale forces with living probes. Nano Lett. 2012, 12, 6018–6023. 10.1021/nl303585w. [DOI] [PubMed] [Google Scholar]
  15. Kress H.; Stelzer E. H.; Rohrbach A. Tilt angle dependent three-dimensional-position detection of a trapped cylindrical particle in a focused laser beam. Appl. Phys. Lett. 2004, 84, 4271–4273. 10.1063/1.1737056. [DOI] [Google Scholar]
  16. Nakayama Y.; et al. Tunable nanowire nonlinear optical probe. Nature 2007, 447, 1098. 10.1038/nature05921. [DOI] [PubMed] [Google Scholar]
  17. Bui A. A.; Stilgoe A. B.; Nieminen T. A.; Rubinsztein-Dunlop H. Calibration of nonspherical particles in optical tweezers using only position measurement. Opt. Lett. 2013, 38, 1244–1246. 10.1364/OL.38.001244. [DOI] [PubMed] [Google Scholar]
  18. Wang F.; et al. Resolving stable axial trapping points of nanowires in an optical tweezers using photoluminescence mapping. Nano Lett. 2013, 13, 1185–1191. 10.1021/nl304607v. [DOI] [PubMed] [Google Scholar]
  19. Grießhammer M.; Rohrbach A. 5D-Tracking of a nanorod in a focused laser beam-a theoretical concept. Opt. Express 2014, 22, 6114–6132. 10.1364/OE.22.006114. [DOI] [PubMed] [Google Scholar]
  20. Mor F. M.; Sienkiewicz A.; Magrez A.; Forró L.; Jeney S. Single potassium niobate nano/microsized particles as local mechano-optical Brownian probes. Nanoscale 2016, 8, 6810–6819. 10.1039/C5NR08090H. [DOI] [PubMed] [Google Scholar]
  21. Smith B. E.; Roder P. B.; Zhou X.; Pauzauskie P. J. Hot Brownian thermometry and cavityenhanced harmonic generation with nonlinear optical nanowires. Chem. Phys. Lett. 2015, 639, 310–314. 10.1016/j.cplett.2015.09.047. [DOI] [Google Scholar]
  22. van Wolferen H. A. G. M.; Abelmann L.. Laser interference lithography. Lithography: Principles, Processes and Materials; NOVA Publishers, 2011; pp 133–148. [Google Scholar]
  23. Santybayeva Z.; et al. Fabrication of quartz microcylinders by laser interference lithography for angular optical tweezers. J. Micro/Nanolithogr., MEMS, MOEMS 2016, 15, 034507. 10.1117/1.JMM.15.3.034507. [DOI] [Google Scholar]
  24. Deufel C.; Forth S.; Simmons C. R.; Dejgosha S.; Wang M. D. Nanofabricated quartz cylinders for angular trapping: DNA supercoiling torque detection. Nat. Methods 2007, 4, 223. 10.1038/nmeth1013. [DOI] [PubMed] [Google Scholar]
  25. Gutiérrez-Medina B.; Andreasson J. O.; Greenleaf W. J.; LaPorta A.; Block S. M.. Methods in Enzymology; Elsevier, 2010; pp 377–404. [DOI] [PMC free article] [PubMed] [Google Scholar]
  26. Huang Z.; Pedaci F.; van Oene M.; Wiggin M. J.; Dekker N. H. Electron beam fabrication of birefringent microcylinders. ACS Nano 2011, 5, 1418–1427. 10.1021/nn1034108. [DOI] [PubMed] [Google Scholar]
  27. Li P.-C.; Chang J.-C.; La Porta A.; Yu E. T. Fabrication of birefringent nanocylinders for single-molecule force and torque measurement. Nanotechnology 2014, 25, 235304. 10.1088/0957-4484/25/23/235304. [DOI] [PubMed] [Google Scholar]
  28. Ha S.; et al. Single-Crystal Rutile TiO2 Nanocylinders are Highly Effective Transducers of Optical Force and Torque. ACS Photonics 2019, 6, 1255–1265. 10.1021/acsphotonics.9b00220. [DOI] [PMC free article] [PubMed] [Google Scholar]
  29. La Porta A.; Wang M. D. Optical torque wrench: angular trapping, rotation, and torque detection of quartz microparticles. Phys. Rev. Lett. 2004, 92, 190801. 10.1103/PhysRevLett.92.190801. [DOI] [PubMed] [Google Scholar]
  30. Pedaci F.; et al. Excitable particles in an optical torque wrench. Nat. Phys. 2011, 7, 259. 10.1038/nphys1862. [DOI] [Google Scholar]
  31. Smith B. E.; et al. Singlet-oxygen generation from individual semiconducting and metallic nanostructures during near-infrared laser trapping. ACS Photonics 2015, 2, 559–564. 10.1021/acsphotonics.5b00022. [DOI] [Google Scholar]
  32. Dreyer J. K.; Berg-Sørensen K.; Oddershede L. Improved axial position detection in optical tweezers measurements. Appl. Opt. 2004, 43, 1991–1995. 10.1364/AO.43.001991. [DOI] [PubMed] [Google Scholar]
  33. Van Oene M. M.; et al. Quantifying the precision of single-molecule torque and twist measurements using Allan variance. Biophys. J. 2018, 114, 1970–1979. 10.1016/j.bpj.2018.02.039. [DOI] [PMC free article] [PubMed] [Google Scholar]
  34. Berg-Sørensen K.; Flyvbjerg H. Power spectrum analysis for optical tweezers. Rev. Sci. Instrum. 2004, 75, 594–612. 10.1063/1.1645654. [DOI] [Google Scholar]
  35. Tirado M. M.; de la Torre J. G. Translational friction coefficients of rigid, symmetric top macromolecules. Application to circular cylinders. J. Chem. Phys. 1979, 71, 2581–2587. 10.1063/1.438613. [DOI] [Google Scholar]
  36. Lansdorp B. M.; Saleh O. A. Power spectrum and Allan variance methods for calibrating single-molecule video-tracking instruments. Rev. Sci. Instrum. 2012, 83, 025115. 10.1063/1.3687431. [DOI] [PMC free article] [PubMed] [Google Scholar]
  37. Gibson G. M.; Leach J.; Keen S.; Wright A. J.; Padgett M. J. Measuring the accuracy of particle position and force in optical tweezers using high-speed video microscopy. Opt. Express 2008, 16, 14561–14570. 10.1364/OE.16.014561. [DOI] [PubMed] [Google Scholar]
  38. Volpe G.; Petrov D. Torque detection using Brownian fluctuations. Phys. Rev. Lett. 2006, 97, 210603. 10.1103/PhysRevLett.97.210603. [DOI] [PubMed] [Google Scholar]
  39. Marago O.; et al. Femtonewton force sensing with optically trapped nanotubes. Nano Lett. 2008, 8, 3211–3216. 10.1021/nl8015413. [DOI] [PubMed] [Google Scholar]
  40. Irrera A.; et al. Size-scaling in optical trapping of silicon nanowires. Nano Lett. 2011, 11, 4879–4884. 10.1021/nl202733j. [DOI] [PubMed] [Google Scholar]
  41. Sanchez C. P.; Karathanasis C.; Sanchez R.; Cyrklaff M.; Jager J.; Buchholz B.; Schwarz U. S.; Heilemann M.; Lanzer M. Single-molecule imaging and quantification of the immune-variant adhesin VAR2CSA on knobs of Plasmodium falciparum-infected erythrocytes. Communications biology 2019, 2, 172. 10.1038/s42003-019-0429-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
  42. Watermeyer J. M.; et al. A spiral scaffold underlies cytoadherent knobs in Plasmodium falciparum–infected erythrocytes. Blood 2016, 127, 343–351. 10.1182/blood-2015-10-674002. [DOI] [PMC free article] [PubMed] [Google Scholar]
  43. Rug M.; Prescott S. W.; Fernandez K. M.; Cooke B. M.; Cowman A. F. The role of KAHRP domains in knob formation and cytoadherence of P falciparum-infected human erythrocytes. Blood 2006, 108, 370–378. 10.1182/blood-2005-11-4624. [DOI] [PMC free article] [PubMed] [Google Scholar]
  44. Mate C. M.; McClelland G. M.; Erlandsson R.; Chiang S. Atomic-scale friction of a tungsten tip on a graphite surface. Phys. Rev. Lett. 1987, 59 (17), 1942–1945. 10.1103/PhysRevLett.59.1942. [DOI] [PubMed] [Google Scholar]
  45. Korchev Y. E.; Bashford C. L.; Milovanovic M.; Vodyanoy I.; Lab M. J. Scanning ion conductance microscopy of living cells. Biophys. J. 1997, 73, 653–658. 10.1016/S0006-3495(97)78100-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  46. Hategan A.; Law R.; Kahn S.; Discher D. E. Adhesively-tensed cell membranes: lysis kinetics and atomic force microscopy probing. Biophys. J. 2003, 85, 2746–2759. 10.1016/S0006-3495(03)74697-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  47. Haro-Gonzalez P.; et al. Optical trapping of NaYF 4: Er 3+, Yb 3+ upconverting fluorescent nanoparticles. Nanoscale 2013, 5, 12192–12199. 10.1039/c3nr03644h. [DOI] [PubMed] [Google Scholar]
  48. Roder P. B.; Smith B. E.; Davis E. J.; Pauzauskie P. J. Photothermal heating of nanowires. J. Phys. Chem. C 2014, 118, 1407–1416. 10.1021/jp4078745. [DOI] [Google Scholar]
  49. Roder P. B.; Smith B. E.; Zhou X.; Crane M. J.; Pauzauskie P. J. Laser refrigeration of hydrothermal nanocrystals in physiological media. Proc. Natl. Acad. Sci. U. S. A. 2015, 112, 15024–15029. 10.1073/pnas.1510418112. [DOI] [PMC free article] [PubMed] [Google Scholar]
  50. Zhou X.; Smith B. E.; Roder P. B.; Pauzauskie P. J. Laser refrigeration of ytterbium-doped sodium–yttrium–fluoride nanowires. Adv. Mater. 2016, 28, 8658–8662. 10.1002/adma.201600406. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

nl0c00729_si_001.pdf (2.4MB, pdf)

Articles from Nano Letters are provided here courtesy of American Chemical Society

RESOURCES