REPLY
We thank Dr. McDonald (1) for his close reading of our paper (2) and acknowledge that he makes important arguments for exercising precautions in order to prevent built environment-mediated transmission of SARS-CoV-2. We would like to address two specific points that Dr. McDonald brings up in relation to our original publication. Dr. McDonald states that we questioned the effectiveness [“Given the virus’s small size, Dietz et al. (3) and others have questioned whether N95 respirators block them.”] of N95 respirators at protecting the wearer from particles “larger than 3 μm.” First, throughout our paper, we do not address the efficiency or efficacy of N95 respirators. We wrote “as masks become available, and while prioritizing access to masks for health care workers that are in a higher risk environment daily, wearing a mask would be prudent,” as was recommended by the Centers for Disease Control (3) and the Food and Drug Administration (4). Since the time of publication, views on the use of cloth and surgical masks in public have changed (https://www.cdc.gov/coronavirus/2019-ncov/prevent-getting-sick/diy-cloth-face-coverings.html), and we acknowledge that they can provide some protection against SARS-CoV-2 but should be combined with other infection prevention measures, such as physical distancing and handwashing.
In regard to Dr. McDonald’s comments about virus size and whether it will be filtered by N95 respirators, we would like to point out that we issued a correction of the paper accepting that what is important here is the size of particles containing the virus and not the size of the virus itself.
Second, we would like to address Dr. McDonald’s claim that installing HEPA filters in homes will “eliminate the risk of air duct transmission.” HEPA filters are very good at removing particles in a broad spectrum of sizes from the air. However, no filter or mechanical system is perfect (5), as demonstrated by recent events at a Children’s Hospital in Seattle, WA (6). Furthermore, the majority of existing built environment mechanical ventilation systems are not capable of having a HEPA filter or high-level MERV filter installed without retrofit measures and consultation with mechanical engineers and mechanical contractors (7).
We thank Dr. McDonald for assessing our review so critically. We do believe, however, that the current body of knowledge supports our statements.
Footnotes
This is a response to a letter by McDonald (https://doi.org/10.1128/mSystems.00390-20).
REFERENCES
- 1.McDonald CJ. 2020. Protections against the risk of airborne SARS-CoV-2 infection. mSystems 5:e00390-20. doi: 10.1128/mSystems.00390-20. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Dietz L, Horve PF, Coil DA, Fretz M, Eisen JA, Van Den Wymelenberg K. 2020. 2019 novel coronavirus (COVID-19) pandemic: built environment considerations to reduce transmission. mSystems 5:e00245-20. doi: 10.1128/mSystems.00245-20. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.CDC. 2020. Interim guidance for the use of masks to control seasonal influenza virus transmission. CDC, Atlanta, GA. [Google Scholar]
- 4.Center for Devices, Radiological Health. 2020. N95 respirators and surgical masks (face masks). US Food and Drug Administration, Silver Spring, MD. [Google Scholar]
- 5.Heimbuch BK, Wu CY, Wander JD. 2009. Viral penetration of high efficiency particulate air (HEPA) filters. Accession no. ADA505315 AFRL-RX-TY-TP-2009-4567 Defense Technical Information Center, Air Force Research Laboratory, Tyndall Air Force Base, FL: https://apps.dtic.mil/dtic/tr/fulltext/u2/a505315.pdf. [Google Scholar]
- 6.Gilbert D, Gutman D. 26 November 2019. Before mea culpa, Children’s was confident its air systems weren’t source of infection. The Seattle Times, Seattle, WA: https://www.seattletimes.com/seattle-news/times-watchdog/before-mea-culpa-childrens-was-confident-its-air-systems-werent-source-of-infection/. [Google Scholar]
- 7.Persily A, Chapman RE, Emmerich SJ, Dols WS, Davis H, Lavappa P, Rushing A. 2007. Building retrofits for increased protection against airborne chemical and biological releases. National Institute of Standards and Technology, Gaithersburg, MD. [Google Scholar]