Comparison of Patient Satisfaction Between Medial Pivot Prostheses and Posterior‐Stabilized Prostheses in Total Knee Arthroplasty

Yuanyuan Lin 1,2, Xueyan Chen 1,2, Li Li 3,4, Zhenxing Li 1,2, Yu Zhang 1,2,, Pei Fan 1,2,
PMCID: PMC7307254  PMID: 32390346

Abstract

Objective

To compare medial pivot (MP) prostheses to two types of posterior‐stabilized (PS) prostheses (NexGen and NRG) in terms of patient satisfaction, causes of dissatisfaction, and risk factors for dissatisfaction after total knee arthroplasty (TKA).

Methods

A total of 453 patients who underwent primary TKA by one senior surgeon from August 2016 to August 2018 were investigated in a retrospective study, including 121, 219, and 113 patients in the MP, NexGen, and NRG groups, respectively. The mean age and follow‐up time of patients were 70.82 ± 7.06 years and 20.64 ± 3.88 months. A survey was designed and responses were collected by telephone, WeChat, and outpatient follow up. Patient satisfaction, causes of dissatisfaction, post‐TKA pain on a numeric rating scale (NRS), and range of motion (ROM) were compared among groups, and risk factors were investigated. Patient satisfaction included a five‐level satisfaction rating (very satisfied, satisfied, neutral, dissatisfied, or very dissatisfied), with five options for causes of dissatisfaction (persistent pain, limited ROM, knee instability, asthenia, and/or other factors).

Results

Overall, 89.84% of patients were satisfied with the results of primary TKA. There were no significant differences among the three groups regarding the side of the operation, the length of hospitalization in days, or the average follow‐up time. Patient satisfaction was similar among the MP (87.38%), NexGen (89.89%), and NRG groups (90.32%). Persistent pain after TKA was the major cause of dissatisfaction (32/40), but no difference in the frequency of this complaint was found among the groups (P = 0.663). The NRS score (P = 0.598) and the ROM (P = 0.959) of the MP group were not significantly different from those of the NexGen and NRG groups. Gender, length of hospitalization, and follow‐up time were all uncorrelated with patient satisfaction, but age showed a very weak correlation with patient satisfaction (r = 0.110, P = 0.033). Moreover, the NRS score (r = 0.459, P < 0.000) and the ROM (r = −0.175, P = 0.001) were significantly correlated with patient dissatisfaction. The odds ratio of dissatisfaction was 6.37 (P < 0.000) in patients with moderate to severe pain (NRS ≥ 3) compared to patients with mild pain (NRS < 3).

Conclusion

Patient satisfaction and function were not found to be higher in the MP group than in the two PS groups, and persistent pain was the major cause of and an important risk factor for patient dissatisfaction.

Keywords: Arthroplasty, Knee, Patient satisfaction, Prostheses and implants, Replacement

Introduction

Total knee arthroplasty (TKA) is the main method used to treat late‐stage knee osteoarthritis and rheumatoid arthritis. Due to its predictable effect of relieving pain and correcting deformity, the frequency of TKA is increasing, as confirmed by many joint registries worldwide1. However, as an important patient reported outcome measure, the patient satisfaction of this procedure is relatively low compared with total hip arthroplasty, ranging from 75% to 92%2, 3. Therefore, several studies have been devoted to determining the causes of dissatisfaction of TKA and trying to improve patient satisfaction through various methods4, 5, 6, 7.

There are numerous factors that can influence patient satisfaction. These factors can be classified as patient‐dependent factors and patient‐independent factors3. The former includes factors such as age, gender, diagnosis, expectations, and preoperative knee function, while the latter refers to surgical technique, rehabilitation training, and design of prostheses3, 8. Among these factors, the design of the prosthesis (e.g. single‐radius or multi‐radius, posterior cruciate ligament [PCL] substitution or retention, conventional or high‐flexion, and geometry of the trochlear groove)9, 10, 11 is considered to be an important factor in patient satisfaction.

Although all of the prostheses are designed to mimic the kinematics of the normal knee, the kinematics are somewhat different from the normal knee in practice. In the normal knee, the femoral condyle has a rollback mechanism to increase the angle of flexion during kneeling or squatting12. To mimic this mechanism, there are currently two major design concepts for prostheses: cruciate‐retaining (CR) and posterior‐stabilized (PS) designs13. The PS prosthesis substitutes the function of the PCL with either the so‐called cam‐and‐post mechanism or a scoop‐shaped tibial polyethylene insert. The motion and rollback of the femoral component are mended during flexion. In contrast, the CR type relies on the PCL to provide stability and to guide femoral rollback. However, it has been reported that 40% of CR prostheses and 60% of PS prostheses may present the phenomenon known as “paradoxical anterior movement” during normal walking, meaning anterior femoral translation during flexion14. This paradoxical anterior movement causes the femoral component to impact the patella and can produce pain around the knee, which may affect patient satisfaction after TKA. Therefore, prosthesis design overcoming the issue of paradoxical anterior movement may be helpful for improving patient satisfaction.

The medial pivot (MP) design was invented to avoid this movement using its special asymmetric polyethylene insert, which has a highly congruent medial compartment and a less conforming lateral compartment. This design allows rolling of the medial femoral condyle, but there is no limitation to the lateral condyle15. Fluoroscopic analysis has confirmed the MP functionality of the prosthesis16. Furthermore, it has been reported that the MP system can mimic the kinematics of the natural knee in rotation, squatting, kicking, and walking up and down the stairs17. Theoretically, this design avoids paradoxical anterior movement and may bring about superior patient satisfaction. However, different reports have achieved conflicting results. For example, Prittchett et al. found that 77% and 79% of patients were more satisfied with MP prostheses than PS and CR prostheses, while Bae et al. found that the improvements of both prostheses were similar when comparing MP prostheses with PS prostheses18, 19, 20. Therefore, it remains controversial whether this design can achieve superior patient satisfaction in practice. In addition, the causes and risk factors for dissatisfaction still need to be further investigated. The understanding of this question could help surgeons to better identify the patients who are likely dissatisfied and provided the corresponding treatment promptly. Therefore, the aims of the present study were: (i) to investigate patient satisfaction after TKA using MP prostheses compared with two PS prostheses to provide further clinical evidence on the MP type; (ii) to explore the causes of dissatisfaction; and (iii) to identify possible risk factors for dissatisfaction.

Materials and Methods

Ethics Statement

The protocol was approved by the ethics committee of the university. Informed consent was obtained from all patients.

Inclusion and Exclusion Criteria

The inclusion criteria were: (i) patients who received primary TKA from one senior surgeon (Z.Y.) in our department from August 2016 to August 2018; (ii) the prostheses used were the Advance (Microport, Arlington, TN, USA), the NexGen (Zimmer, Warsaw, IN, USA) or the Scorpio NRG (Stryker, Mahwah, NJ, USA) systems (the Advance prosthesis is an MP design, while the NexGen and NRG prostheses are PS designs); (iii) the major evaluation indicators included level of satisfaction, causes of dissatisfaction, level of pain, and range of motion (ROM); and (iv) this study is a retrospective study.

The exclusion criteria were: (i) revised cases; (ii) patients who had a history of spinal or spinal cord disease affecting the pain judgment of the knee; (iii) patients who had serious medical diseases that affected the recovery of joint function; and (iv) patients with previous TKA in the other knee.

Surgical Procedures

All the operations were performed with patients in a supine position under spinal or general anesthesia as follows. A tourniquet was kept in place constantly to obtain a bloodless field. Initially, a longitudinal midline skin incision was made at the knee joint. Then, the meniscus and synovium were completely resected, and part of the fat pad under the tibia was removed. After the ligaments and the posterior joint capsules were released to achieve a primary balance, osteotomy procedures were performed according to the manual. The prosthesis was fixed in place after the flexion and extension gaps were balanced. Autologous blood transfusion was used, and rehabilitation was performed according to a standard protocol.

Data Collection

A survey was designed and responses were collected by telephone, WeChat software (Tencent Tech, Shenzhen, China) and outpatient follow up. This survey collected two categories of information: basic and satisfaction information. Basic information included demographic characteristics, diagnosis, days of hospitalization, and prosthesis information. Satisfaction information included the following types of information.

Five‐Level Satisfaction Rating

The satisfaction rating defined the level of satisfaction of patients. It included a five‐level satisfaction rating (very satisfied, satisfied, neutral, dissatisfied, or very dissatisfied). Generally, “very satisfied” and “satisfied” patients were defined as the satisfied group, while “neutral,” “dissatisfied,” and “very dissatisfied” patients were defined as the dissatisfied group.

Causes of Dissatisfaction

Causes of dissatisfaction described the causes why patients were dissatisfied with the operation when they were classified into the dissatisfied group. Five options for causes of dissatisfaction (persistent pain, limited ROM, knee instability, asthenia, and/or other factors) were listed in the survey.

Numeric Rating Scale Pain Score

The numeric rating scale (NRS) is a method commonly used to evaluate the level of pain. Patients rated their pain on a scale that had 11 points, from 0 to 10. Zero means “no pain,” while 10 means “the worst possible pain.”21. The mild pain group was classified as NRS < 3, while moderate–severe pain was classified as NRS ≥ 3.

Knee Range of Motion

Knee ROM recorded the angle of motion from extension to flexion after TKA. The pictures of maximum extension and flexion of patients were collected by email or WeChat or outpatient follow up and were analyzed using an app named Bangni (Bangni Online Tech, Beijing, China).

Statistical Analysis

Data analysis and statistics were processed using SPSS 20.0 (IBM, Armonk, NY, USA). Patient characteristics were reported as the mean and standard deviation. Pain scores and knee ROM were described as the mean and 95% confidence interval. The χ2‐test was used for satisfaction analysis. A non‐parametric rank sum test was used to compare pain and ROM between groups. Correlation was analyzed using Spearman's rho. P < 0.05 was defined as a significant difference.

Results

Patient Demography

Initially, 453 patients were enrolled in this study. However, 79 patients were lost to follow up during the investigation. Therefore, a total of 374 patients were included and analyzed in the retrospective study (Fig. 1). The demography and patient characteristics of each group are illustrated in Table 1. Most of the women used NexGen prostheses (173/255), and most of the men used Advance (70/119) or NRG (44/119) devices. The average age in the MP group was similar to that in the NexGen group and approximately 3.8 years younger than that in the NRG group. There was no significant difference among the three groups regarding the side of the operation, the length of hospitalization in days, or the average follow‐up time. Most patients had been diagnosed with knee osteoarthritis. Typical images of one MP and two PS prostheses are shown in Fig. 2.

Figure 1.

Figure 1

Flow chart for the selection of patients in different groups.

Table 1.

Demography and other characteristics of patients in the three groups

MP group PS group Total
NexGen NRG
Male/female 70/33 5/173 44/49 119/255
Age (years) 70.38 ± 6.37 69.32 ± 7.42 74.18 ± 5.89 70.82 ± 7.06
Left/right 91/87 53/50 46/47 190/184
Days of hospitalization 10.98 ± 4.06 11.37 ± 4.13 11.82 ± 4.26 11.37 ± 4.14
Months of follow up 19.22 ± 3.17 21.52 ± 3.74 20.53 ± 4.38 20.64 ± 3.88
Diagnosis
OA 102 174 92 368
RA 1 3 1 5
Others 0 1 0 1
Total 103 178 93 374

MP, medial pivot; NexGen, NexGen prosthesis from Zimmer; NRG, Scorpio NRG prosthesis from Stryker; OA, osteoarthritis; PS, posterior‐stabilized; RA, rheumatoid arthritis.

Figure 2.

Figure 2

X‐ray images before and after total knee arthroplasty (TKA) using a medial pivot (MP) prosthesis and two PS prostheses. (A) MP prosthesis (Advance, Microport, Arlington, TN, USA); (B) posterior‐stabilized (PS) prosthesis (NexGen, Zimmer, Warsaw, IN, USA); (C) PS prosthesis (Scorpio NRG, Stryker, Mahwah, NJ, USA). AP, anteroposterior.

Patient Satisfaction and Causes of Dissatisfaction in Different Groups

To investigate patient satisfaction in each group, we collected a survey from patients. The overall rate of patient satisfaction was 89.84%. The numbers of satisfied and dissatisfied patients in each group are presented in Fig. 3. Although the MP group had lower patient satisfaction (87.38%) than the NexGen group (89.89%) and the NRG group (90.32%), there was no significant difference among groups (P = 0.754). In addition, gender, length of hospitalization, and follow‐up time were all uncorrelated with patient satisfaction, but age showed a very weak correlation with patient satisfaction (r = 0.110, P = 0.033). In brief, the MP group did not exhibit superior patient satisfaction compared with the two PS groups.

Figure 3.

Figure 3

Percentage of satisfaction after total knee arthroplasty (TKA) using three prostheses. The number of patients is shown in each bar. The percentage of satisfaction is shown above each bar.

To explore the causes of dissatisfaction, we administered a survey asking patients why, if at all, they were dissatisfied; the response options were persistent pain, limited ROM, instability of the knee, asthenia of the knee, and other causes. The dissatisfied patients in each group are summarized in Table 2 along with the reasons for their dissatisfaction. In total, 80.0% (32/40) of dissatisfied patients felt pain related to the knee, and 55.0% (22/40) of dissatisfied patients reported pain alone as the cause. Moreover, pain was the major cause of patient dissatisfaction in every group. Four dissatisfied patients complained of a limited ROM, instability of the knee or asthenia alone. Ten patients were dissatisfied with the results for multiple reasons. However, the MP group did not significantly differ from the two PS groups in the distribution of causes for dissatisfaction (P = 0.663). Regarding complications, one patient in the MP group developed a superficial infection, and one patient in the NRG group developed a deep infection. The former patient was cured after using antibiotics, while the latter patient was diagnosed with periprosthetic joint infection 8 months later and received revised TKA. One of the dissatisfied patients in the MP group suffered a stroke after the operation. No other complications were found in any of the three groups. In short, pain was the major cause of patient dissatisfaction but did not differ in frequency among groups.

Table 2.

Causes of patient dissatisfaction in the three groups

MP group PS group Total
Advance NexGen NRG
1 Pain 8 8 6 22
2 Limited ROM 1 0 0 1
3 Unstable 1 0 1 2
4 Asthenia 0 1 0 1
5 Pain + Limited ROM 1 2 0 3
6 Pain + Unstable 0 1 1 2
7 Pain + Asthenia 1 3 0 4
8 Pain + Limited ROM + Asthenia 0 1 0 1
9 Other Reasons 1 2 1§ 4
Total 13 18 9 40

This patient was dissatisfied because of a stroke after the operation.

One patient was dissatisfied because the outcome of TKA did not meet her expectations, and the other patient was dissatisfied because the knee made a noise when moving.

§

This patient developed periprosthetic joint infection preceded by persistent knee pain.

MP, medial pivot; NexGen, NexGen prosthesis from Zimmer; NRG, Scorpio NRG prosthesis from Stryker; OA, osteoarthritis; PS, posterior‐stabilized; RA, rheumatoid arthritis; ROM, range of motion.

The MP Group Had Similar Postoperative Pain and ROM to the PS Groups

To further compare the clinical results between the MP group and PS groups, NRS pain scores and ROM were analyzed (Table 3). In total, 29.9% (112/374) of patients still had varying degrees of knee pain. However, no significant difference was found among groups in terms of pain scores (P = 0.598). In addition, compared with the two PS groups, the MP group did not exhibit superior ROM (P = 0.959). Therefore, MP prostheses had similar pain and ROM results to PS prostheses.

Table 3.

Number of painful knees, pain score, and ROM in each of the three groups

Number of painful knees NRS (mean, 95% CI) ROM (degrees) n
Advance 35 0.67 (0.45–0.89) 98.6 (96.0–101.2) 103
NexGen 49 0.54 (0.40–0.69) 98.3 (96.4–100.1) 178
NRG 28 0.60 (0.40–0.81) 97.9 (94.6–101.2) 93
Total 112 0.59 (0.49–0.70) 98.3 (96.9–99.7) 374

CI, confidence interval; NexGen, NexGen prosthesis from Zimmer; NRG, Scorpio NRG prosthesis from Stryker; NRS, numeric rating scale; ROM, range of motion.

Persistent Pain was a Critical Risk Factor for Patient Dissatisfaction

To further investigate risk factors of patient dissatisfaction, we compared pain scores between satisfied and dissatisfied patients (Supplement Table 1). NRS scores were significantly higher in dissatisfied patients than in satisfied patients (P < 0.000) and were significantly correlated with satisfaction (r = 0.459, P < 0.000). Furthermore, compared with the mild pain group (NRS < 3), the odds ratio (OR) of dissatisfaction reached 6.37 (P < 0.000) in the moderate–severe pain group (NRS≥3). However, ROM was significantly better in the satisfied group than in the dissatisfied patients (P = 0.002) and was significantly negatively correlated with patient dissatisfaction (r = −0.175, P = 0.001). In summary, pain scores were a critical risk factor correlated with patient satisfaction.

Discussion

Patient satisfaction after TKA is one of the most important issues facing doctors and patients3. Different prosthesis designs lead to varied knee kinematics and result in discrepant satisfaction rates3, 8, 10. Despite efforts to mimic the motion of the natural knee, paradoxical anterior movement is still a common phenomenon after TKA and leads to various discomforts, such as pain caused by patellofemoral impact during flexion, which reduces patient satisfaction and joint function scores14. CR and PS prostheses may exhibit this phenomenon during normal walking, deep squatting, and other activities17. The MP prothesis, designed with the goal of overcoming this disadvantage, was first introduced by Wright Medical Technology in 1998. The prosthesis uses a ball‐in‐socket design with a raised anteroposterior lip (Fig. 4A,B) and does not roll back, in contrast to the post‐and‐cam mechanism of PS arthroplasties; therefore, this design theoretically prevents paradoxical anterior movement22, 23, 24. Furthermore, the MP system has been reported to mimic the kinematics of the natural knee in several studies16, 17. With these characteristics, MP prostheses achieved good clinical outcomes. Macheras et al. found that the function of the knee greatly improved after TKA using MP in 325 patients, as assessed by the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Short Form (SF)‐12, and Oxford Knee scores25. Karachalios et al. found that the 15‐year cumulative survival rate of MP reached 97.7% and that the average ROM was 117° (85°–130°)22. Prittchett et al. compared the MP prosthesis with PS and CR prostheses and found that 77% and 79% of patients, respectively, were more satisfied with MP prostheses because they felt that those prostheses were more natural and powerful during walking and going up or down stairs, more stable, and less noisy18, 19. Therefore, MP prostheses could achieve good clinical results by greatly reducing pain and improving the function of the knee. Owing to the good performance of this type of design, different MP systems were invented by different companies, including the SAIPH (TM) prosthesis (MatOrtho Corporation, UK), the FINE prosthesis (Nakashima, Japan) and the Persona prosthesis with internal shaft gaskets (DEPUY, USA).

Figure 4.

Figure 4

The Advance prosthesis. (A) The polyethylene insert used in the Advance prosthesis system. L, lateral side; M, medial side. (B). The femoral component and the polyethylene insert in the Advance prosthesis from a medial view. M, medial side.

Due to the advantages of the MP prosthesis, its design was expected to achieve superior patient satisfaction. However, in this study, the MP group did not show an improvement in patient satisfaction, ROM, or pain score compared to the other two PS designs. This result was consistent with some previous studies. After comparing MP prostheses with PS prostheses, Bae et al. found that the improvements of both prostheses were similar, while MP prostheses did not show the expected advantage in relieving patellar symptoms20. Choi et al. found that self‐reported scores were similar between MP prostheses and PFC mobile‐bearing prostheses, but patients preferred PFC prostheses when they were involved in more demanding activities26. Kim et al. reported that the survival rates of the MP and PFC CR groups were almost identical, but the PFC CR group had better knee function than the MP groups and had fewer complications (5% vs. 26%)24. Another study analyzed the patellar track after TKA using MP prosthesis and found that the MP prosthesis could not mimic the natural track of the patella27, 28. Therefore, from the above‐described research and our results, it is still controversial whether MP prostheses achieve better patient satisfaction and knee function than other prosthesis designs.

Persistent pain after TKA is still the major problem affecting the improvement of satisfaction in our study. This outcome is consistent with other research7, 29. However, no significant difference was found between the MP group and the PS groups. This is mainly due to the complicated causes of pain. Although causes of pain after TKA have been reported in numerous studies, the exact mechanisms still need to be further investigated. Generally, the mechanisms include host factors, surgical techniques, infection and prosthesis features. Among these mechanisms, prosthesis design leads to different degrees and types of pain in several ways. For example, some prosthesis designs were demonstrated to have high pressure at the patellofemoral joint, leading to patellar pain30, 31. In addition, different materials and bearing types may lead to various degrees of polyethylene wear and aseptic loosening32. In this study, we found that pain existed in 29.9% of patients after TKA; these data were consistent with other research3. Furthermore, we found a significant correlation between pain or ROM and patient satisfaction. Similar to our results, several other studies have reported that pain and ROM play critical roles in patient satisfaction7, 29. Moreover, we found that pain was an important risk factor related to patient satisfaction. Therefore, exploring the mechanisms of pain and reduction of pain would inform efforts to increase patient satisfaction.

This study has several limitations. First, the demography of patients may affect their satisfaction ratings. On the one hand, NexGen prosthesis was used in most of the females, while most of the males used Advance or NRG prostheses. The significant intergroup difference in gender ratio may affect the results. On the other hand, age could also be an important factor affecting the outcome. Second, the follow‐up period was relatively short. In the future, randomized, multi‐centre studies with large sample sizes are needed to clarify this issue.

Conclusion

In summary, this study showed that MP prostheses achieved satisfactory short‐term clinical outcomes, but not superior to PS protheses. Persistent pain served as an important risk factor for dissatisfaction after TKA.

Conflict of Interest

On behalf of all authors, the corresponding author states that there is no conflict of interest.

Grant Sources: This work was supported by the National Natural Science Foundation of China (81702660), the Zhejiang Provincial Natural Science Foundation (LQ17C120002), and the Zhejiang Provincial Medical Health Science and Technology Plan Project (2017KY469).

Disclosure: All authors declare that they have no conflicts of interest.

Contributor Information

Yu Zhang, Email: fanpei@wmu.edu.cn, Email: yu.zhang@wmu.edu.cn.

Pei Fan, Email: fanpei@wmu.edu.cn.

References

  • 1. Price AJ, Alvand A, Troelsen A, et al Knee replacement. Lancet, 2018, 392: 1672–1682. [DOI] [PubMed] [Google Scholar]
  • 2. Bourne RB, Chesworth B, Davis A, Mahomed N, Charron K. Comparing patient outcomes after THA and TKA: is there a difference? Clin Orthop, 2010, 468: 542–546. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3. Choi YJ, Ra HJ. Patient satisfaction after total knee arthroplasty. Knee Surg Relat Res, 2016, 28: 1–15. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4. Matsuda S, Kawahara S, Okazaki K, Tashiro Y, Iwamoto Y. Postoperative alignment and ROM affect patient satisfaction after TKA. Clin Orthop, 2013, 471: 127–133. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5. Du H, Tang H, Gu JM, Zhou YX. Patient satisfaction after posterior‐stabilized total knee arthroplasty: a functional specific analysis. Knee, 2014, 21: 866–870. [DOI] [PubMed] [Google Scholar]
  • 6. Baker PN, Deehan DJ, Lees D, et al The effect of surgical factors on early patient‐reported outcome measures (PROMS) following total knee replacement. J Bone Joint Surg Br, 2012, 94: 1058–1066. [DOI] [PubMed] [Google Scholar]
  • 7. Bourne RB, Chesworth BM, Davis AM, Mahomed NN, Charron KD. Patient satisfaction after total knee arthroplasty: who is satisfied and who is not? Clin Orthop, 2010, 468: 57–63. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8. Digennaro V, Zambianchi F, Marcovigi A, Mugnai R, Fiacchi F, Catani F. Design and kinematics in total knee arthroplasty. Int Orthop, 2014, 38: 227–233. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9. Luo Z, Luo Z, Wang H, Xiao Q, Pei F, Zhou Z. Long‐term results of total knee arthroplasty with single‐radius versus multi‐radius posterior‐stabilized prostheses. J Orthop Surg Res, 2019, 14: 139. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10. Kahlenberg CA, Lyman S, Joseph AD, Chiu YF, Padgett DE. Comparison of patient‐reported outcomes based on implant brand in total knee arthroplasty: a prospective cohort study. Bone Joint J, 2019, 101‐B: 48–54. [DOI] [PubMed] [Google Scholar]
  • 11. Woiczinski M, Kistler M, Schroder C, et al TKA design‐integrated trochlea groove rotation reduces patellofemoral pressure. Knee Surg Sports Traumatol Arthrosc, 2019, 27: 1680–1692. [DOI] [PubMed] [Google Scholar]
  • 12. Komistek RD, Dennis DA, Mahfouz M. In vivo fluoroscopic analysis of the normal human knee. Clin Orthop, 2003, 410: 69–81. [DOI] [PubMed] [Google Scholar]
  • 13. Longo UG, Ciuffreda M, Mannering N, et al Outcomes of posterior‐stabilized compared with cruciate‐retaining total knee arthroplasty. J Knee Surg, 2018, 31: 321–340. [DOI] [PubMed] [Google Scholar]
  • 14. Dennis DA, Komistek RD, Mahfouz MR. In vivo fluoroscopic analysis of fixed‐bearing total knee replacements. Clin Orthop, 2003, 410: 114–130. [DOI] [PubMed] [Google Scholar]
  • 15. Schmidt R, Ogden S, Blaha JD, Alexander A, Fitch DA, Barnes CL. Midterm clinical and radiographic results of the medial pivot total knee system. Int Orthop, 2014, 38: 2495–2498. [DOI] [PubMed] [Google Scholar]
  • 16. Miyazaki Y, Nakamura T, Kogame K, Saito M, Yamamoto K, Suguro T. Analysis of the kinematics of total knee prostheses with a medial pivot design. J Arthroplasty, 2011, 26: 1038–1044. [DOI] [PubMed] [Google Scholar]
  • 17. Shimmin A, Martinez‐Martos S, Owens J, Iorgulescu AD, Banks S. Fluoroscopic motion study confirming the stability of a medial pivot design total knee arthroplasty. Knee, 2015, 22: 522–526. [DOI] [PubMed] [Google Scholar]
  • 18. Pritchett JW. Patient preferences in knee prostheses. J Bone Joint Surg Br, 2004, 86B: 979–982. [DOI] [PubMed] [Google Scholar]
  • 19. Pritchett JW. Patients prefer a bicruciate‐retaining or the medial pivot total knee prosthesis. J Arthroplasty, 2011, 26: 224–228. [DOI] [PubMed] [Google Scholar]
  • 20. Bae DK, Do CS, Im SK, Song SJ. Comparison of midterm clinical and radiographic results between total knee arthroplasties using medial pivot and posterior‐stabilized prosthesis‐a matched pair analysis. J Arthroplasty, 2016, 31: 419–424. [DOI] [PubMed] [Google Scholar]
  • 21. Albayrak I, Apiliogullari S, Erkocak OF , Kavalci H, Ozerbil OM, Levendoglu F. Total knee arthroplasty due to knee osteoarthritis: risk factors for persistent postsurgical pain. J Natl Med Assoc, 2016, 108: 236–243. [DOI] [PubMed] [Google Scholar]
  • 22. Karachalios T, Varitimidis S, Bargiotas K, Hantes M, Roidis N, Malizos KN. An 11‐to 15‐year clinical outcome study of the advance medial pivot total knee arthroplasty pivot knee arthroplasty. Bone Joint J, 2016, 98B: 1050–1055. [DOI] [PubMed] [Google Scholar]
  • 23. Karachalios T, Roidis N, Giotikas D, Bargiotas K, Varitimidis S, Malizos KN. A mid‐term clinical outcome study of the advance medial pivot knee arthroplasty. Knee, 2009, 16: 484–488. [DOI] [PubMed] [Google Scholar]
  • 24. Kim YH, Park JW, Kim JS. Clinical outcome of medial pivot compared with press‐fit condylar sigma cruciate‐retaining mobile‐bearing total knee arthroplasty. J Arthroplasty, 2017, 32: 3016–3023. [DOI] [PubMed] [Google Scholar]
  • 25. Macheras GA, Galanakos SP, Lepetsos P, Anastasopoulos PP, Papadakis SA. A long term clinical outcome of the medial pivot knee arthroplasty system. Knee, 2017, 24: 447–453. [DOI] [PubMed] [Google Scholar]
  • 26. Choi NY, In Y, Bae JH, Do JH, Chung SJ, Koh IJ. Are midterm patient‐reported outcome measures between rotating‐platform mobile‐bearing prosthesis and medial‐pivot prosthesis different? A minimum of 5‐year follow‐up study. J Arthroplasty, 2017, 32: 824–829. [DOI] [PubMed] [Google Scholar]
  • 27. Chinzei N, Ishida K, Matsumoto T, et al Evaluation of patellofemoral joint in ADVANCE (R) medial‐pivot total knee arthroplasty. Int Orthop, 2014, 38: 509–515. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28. Ishida K, Matsumoto T, Tsumura N, et al In vivo comparisons of patellofemoral kinematics before and after ADVANCE(a (R)) medial‐pivot total knee arthroplasty. Int Orthop, 2012, 36: 2073–2077. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29. Sakellariou VI, Poultsides LA, Ma Y, Bae J, Liu S, Sculco TP. Risk assessment for chronic pain and patient satisfaction after total knee arthroplasty. Orthopedics, 2016, 39: 55–62. [DOI] [PubMed] [Google Scholar]
  • 30. Heyse TJ, Becher C, Kron N, et al Patellofemoral pressure after TKA in vitro: highly conforming vs posterior stabilized inlays. Arch Orthop Trauma Surg, 2010, 130: 191–196. [DOI] [PubMed] [Google Scholar]
  • 31. Tanikawa H, Tada M, Harato K, Okuma K, Nagura T. Influence of total knee arthroplasty on patellar kinematics and patellofemoral pressure. J Arthroplasty, 2017, 32: 280–285. [DOI] [PubMed] [Google Scholar]
  • 32. Minoda Y, Hata K, Ikebuchi M, Mizokawa S, Ohta Y, Nakamura H. Comparison of in vivo polyethylene wear particles between mobile‐ and fixed‐bearing TKA in the same patients. Knee Surg Sports Traumatol Arthrosc, 2017, 25: 2887–2893. [DOI] [PubMed] [Google Scholar]