Skip to main content
European Heart Journal. Case Reports logoLink to European Heart Journal. Case Reports
. 2020 May 8;4(3):1–6. doi: 10.1093/ehjcr/ytaa102

Transcatheter aortic valve replacement for bicuspid aortic valve regurgitation in a 17-year-old patient with congenitally corrected transposition of great arteries: a case report

Takahiro Nomura y1,, Masaki Miyasaka y1, Evan M Zahn y2, Raj R Makkar y1
Editors: Georg Goliasch, Maria Antonieta Albanez A de Medeiros Lopes, Dejan Milasinovic, Christian Fielder Camm, Peregrine Green
PMCID: PMC7319830  PMID: 32617485

Abstract

Background

Limited research has been conducted on the surgical management of the aortic valve in congenitally corrected transposition of great arteries (ccTGA) and to our knowledge there have been no reports on the treatment of bicuspid aortic regurgitation (AR) in ccTGA. We report on a ccTGA patient with bicuspid AR and systemic right ventricule (SRV) dysfunction who underwent transcatheter aortic valve replacement (TAVR).

Case summary

A 17-year-old male with a history of ccTGA and cerebral palsy diagnosed at birth presented with heart failure. During childhood, he did not experience any heart failure symptoms, however, secondary to progressive bicuspid AR he experienced worsening SRV dysfunction beginning at 15-year-old. Echocardiography showed reduced SRV ejection fraction and severe bicuspid AR. The heart team, including a cardiac surgeon and paediatric cardiologist, discussed the treatment strategies and decided to proceed with TAVR as surgical aortic valve replacement was deemed high risk. TAVR was performed with the 34 mm Evolut R (Medtronic, Minneapolis, MN, USA). Post-operative echocardiography showed severe paravalvular leak (PVL). Therefore, valve-in-valve TAVR using a 29 mm Edwards SAPIEN 3 (Edwards Lifesciences, Irvine, CA, USA) was performed on post-operative Day 2 for PVL reduction. Following second procedure, PVL was significantly improved. The patient was discharged in stable condition.

Discussion

This is the first case wherein TAVR was performed for bicuspid AR in a patient with ccTGA. With appropriate preparation and planning and a collaborative multi-disciplinary team approach, TAVR can be a treatment option for severe AR in patients with ccTGA at high risk for surgery.

Keywords: Case report, Transcatheter aortic valve replacement, Congenitally corrected transposition of great arteries, Bicuspid aortic valve, Aortic regurgitation


Learning points

  • We report the case of a surgical high-risk congenitally corrected transposition of great arteries (ccTGA) patient who underwent transcatheter aortic valve replacement (TAVR) for bicuspid aortic regurgitation (AR).

  • As post-operative echocardiography demonstrated severe paravalvular leak (PVL), valve-in-valve TAVR was performed on post-operative Day 2 for the purpose of PVL reduction. Following second procedure, PVL was improved.

  • With appropriate preparation and planning and a collaborative multi-disciplinary team approach, TAVR can be a treatment option for severe AR in patients with ccTGA at high risk for surgery.

Introduction

Congenitally corrected transposition of great arteries (ccTGA) is a rare disease. The frequency is reported to be 1/33 000 live births, accounting for ∼0.05% of congenital heart disease.1 It has been reported that 84% of cases of ccTGA are associated with other cardiac defects.2 Common defects associated with ccTGA are ventricular septal defect (VSD), pulmonary stenosis, tricuspid regurgitation, and Ebstein’s anomaly of the systemic atrioventricular valve. Additionally, although infrequent, aortic regurgitation (AR) has been associated in 7% of patients with ccTGA.2 These associated cardiac malformations may require surgical treatment depending on their severity, and systemic right ventricle (SRV) dysfunction is often associated with increased operative risk.3 Herein, the authors report the case of a 17-year-old patient with ccTGA and SRV dysfunction who developed severe AR and was treated with transcatheter aortic valve replacement (TAVR) rather than surgical aortic valve replacement because of presumed elevated surgical risk associated with SRV dysfunction. Little information is available regarding the treatment of bicuspid aortic stenosis (AS) in patients with ccTGA. Only two case reports on such patients exist,4,5 and there are no other studies describing AR in patients with ccTGA and bicuspid aortic valve. The authors believe that a detailed description of this case provides valuable information.

Timeline

Time Events
Prior to presentation 17-year-old male
Congenitally corrected transposition of great arteries
Bicuspid aortic regurgitation
Systemic right ventricle dysfunction
Cerebral palsy
Day 0: transcatheter aortic valve replacement (TAVR) TAVR using a 34 mm Medtronic Evolut R
Post-operative echocardiography showed severe paravalvular leak (PVL)
Post-operative Day 2: valve-in-valve TAVR Valve-in-valve TAVR using a 29 mm Edwards SAPIEN 3 for PVL reduction
Following valve-in-valve procedure, PVL was significantly improved
Post-operative Day 4: patient discharge The patient was discharged in stable condition

Case presentation

A 17-year-old male was diagnosed at birth with ccTGA, VSD, bicuspid aortic valve, and cerebral palsy. During childhood VSD closure occurred spontaneously and he was virtually asymptomatic until age 15. At that time, he was noted to have progressive bicuspid AR associated with SRV dysfunction. He developed worsening symptoms of heart failure despite the institution of medical therapy. He presented at our hospital for consultation on alternative treatment strategies for his AR. Physical examination revealed malaise and fatigue. His blood pressure was 102/49 mmHg. A grade 3/6 diastolic murmur was present. Water hammer wrist pulses were felt. Transthoracic echocardiography revealed an enlarged SRV with ejection fraction (EF) decreased to 28%. Aortic valve morphology was bicuspid, with severe AR. There was mild mitral regurgitation and mild-to-moderate systemic tricuspid regurgitation (TR). Transoesophageal echocardiography demonstrated severe eccentric AR (Figure 1) without an atrial- or ventricular-level shunt. Multidetector computed tomography showed an annulus mean diameter of 26.9 mm, annulus area of 506.3 mm2, annulus perimeter of 80.9 mm, and sinus of valsalva area was 908.9 mm2. The right coronary height was 18.8 mm, and the left coronary height was 27.5 mm. There was no calcification in the aortic valve complex. The SRV outflow tract had an irregular shape (Figures 2 and 3). The heart team, including an experienced cardiac surgeon and a congenital interventional cardiologist discussed the treatment strategy based on these results and ultimately decided to proceed with TAVR as surgical aortic valve replacement was deemed high risk. Under general anaesthesia, TAVR was performed using a transfemoral approach, and a 34 mm Medtronic Evolut R was implanted. Shortly after the procedure, post-operative echocardiography demonstrated severe paravalvular leak (PVL) necessitating a valve-in-valve TAVR using a 29 mm Edwards SAPIEN 3 performed on post-operative Day 2 for the purpose of PVL reduction (Figure 4,Supplementary materail online, Video S1). Following this second procedure, PVL was significantly improved (Figure 5). The final pre-discharge echocardiogram shows that the peak aortic valve jet velocity was 3.58 m/s, while the aortic valve mean pressure gradient was 23.84 mmHg, and there was no description of the right ventricular ejection fraction (RVEF). The patient was discharged in a stable condition on post-operative Day 4. No further follow-up is available because of the patient transferred their care to another hospital.

Figure 1.

Figure 1

Baseline transoesophageal echocardiography, long-axis view. Severe eccentric aortic regurgitation. Ao, aorta; LA, left atrium; SRV, systemic right ventricle.

Figure 2.

Figure 2

Multidetector computed tomography volume rendering image. Anatomical location relationship. Ao, aorta; LA, left atrium; LV, left ventricle; PA, pulmonary artery; RA, right atrium; SRV, systemic right ventricle.

Figure 4.

Figure 4

Fluoroscopic image. (A) Positioning of first valve. (B) Post-operative contrast of first valve. (C) Deployment of second valve. (D) Post-second valve deployment. The red lines in (A) and (B) are imaginary lines of aortic valve annulus height. When compared to (A), (B) shows that valve dislocation too deep for the height of one stent strut occurred. In (C) and (D), the second valve fully extends to the waist part of first valve. First valve: 34 mm Medtronic Evolut R. Second valve: 29 mm Edwards SAPIEN 3.

Figure 5.

Figure 5

Pre- and post-transoesophageal echocardiography short-axis view for valve-in-valve transcatheter aortic valve replacement. (A) Pre-transoesophageal echocardiography short-axis view. (B) Post-transoesophageal echocardiography short-axis view. Following valve-in-valve transcatheter aortic valve replacement, paravalvular leak was significantly improved.

Figure 3.

Figure 3

Multidetector computed tomography aortic valve complex analysis. (A) Sinotubular junction. (B) Sinuses of Valsalva. (C) Aortic annulus. (D) Systemic right ventricular outflow tract.

Discussion

To the best of our knowledge, this is the first published case of TAVR for bicuspid AR in the setting of ccTGA with SRV dysfunction. While asymptomatic throughout early childhood, at 15 years of age this patient presented with heart failure symptoms related to the progression of AR and SRV. Previous studies have suggested that SRV dysfunction associated with systemic atrioventricular valve regurgitation (tricuspid regurgitation) in cases of unoperated adult ccTGA is problematic.6 A preoperative SRV EF of <40% has been shown to be a predictor of poor prognosis in cases of unoperated adult ccTGA with SRV dysfunction requiring surgical tricuspid valve replacement.3 In the present case, although the target valve was the aortic valve, the heart team believed that this patient’s severe SRV dysfunction placed him at high operative risk prompting a decision to proceed with TAVR in this unique setting.

TAVR for symptomatic severe AS is widely perceived as an established procedure, however, there are only a few reports of TAVR for bicuspid AR and the safety of this treatment, even in a so-called normal anatomic setting is not well established. In this case, preoperative multiplanar imaging suggested that the 34 mm Medtronic Evolut R would be best suited to the unusual configuration of the left ventricular outflow tract in the setting of ccTGA. However, post-operative echocardiography showed severe PVL. It has been reported that significant PVL after TAVR is strongly associated with poor prognosis.7 For the purpose of PVL reduction, valve-in-valve TAVR was performed with a 29 mm Edwards SAPIEN 3 on post-operative Day 2, and PVL improvement was subsequently observed. After the first TAVR procedure, the authors thought deep implantation of transcatheter heart valve (THV)8 was the principal cause of the severe PVL. However, a simultaneous potential cause via the under-expansion of the THV could not be denied. Therefore, the authors waited 2 days for the decrement of PVL due to THV’s self-expansion. However, AR did not decrease on post-operative Day 2. To remove the two potential causes, the primary operator decided to implant the SAPIEN3 valve, which has a stronger radial force than Evolut R, as the second valve.

Although a vascular plug would be another treatment option for PVL, we presumed that the use of a vascular plug was not effective because of its inability to seal the full circumferential jet of PVL. Unlike aortic valve stenosis, little or no calcification is observed in the aortic valve of patients with pure AR. In the absence of aortic valve calcification that might help anchor the THV, TAVR for pure native AR has been associated with valve dislocation.9 In this case, no calcification of the aortic valve leaflet was observed placing this patient at risk for this complication. Additionally, the unusual orientation and anatomic structure of left ventricular outflow tract in ccTGA (i.e. presence of a subaortic conus) may have contributed to the observed valve dislocation (Figure 4). Ultimately, the performance of valve-in-valve TAVR utilizing a balloon-expandable valve served to markedly improve PVL as the SAPIEN 3 valve served to fully expand Evolut R through application of radial force. Perhaps not surprisingly, during the second procedure, deployment of the SAPIEN 3 valve to a precise position was simplified as the previously placed Evolut R served as an easily identifiable anchoring landing zone.

The long-term durability of THV over 10 years remains unknown, although recent investigations have revealed similar or better durability of THV in haemodynamic performance based on echocardiography compared to a surgical valve over 5–10 years.10,11 In this study, the patient who underwent TAVR was young. Therefore, the long-term management strategy for this patient requires regular follow-up by the cardiologist and periodic examinations, including transthoracic echocardiography. This case had no other treatment option because the patient was at high risk for surgery. However, the durability of THV should be taken into account when considering TAVR as a treatment option for a young patient.

TAVR is a minimally invasive procedure compared to surgical aortic valve replacement and has been shown to serve an important role in high-risk patients with complex anatomy.12,13 In this case, although a second valve deployment was required, an optimal result was ultimately achieved without the need for high-risk open-heart surgery. This result suggests that TAVR should be considered a treatment option for severe AR in patients with ccTGA at high risk for surgery.

Conclusion

To the best of our knowledge, this is the first case performed with TAVR for bicuspid AR in the context of ccTGA. With appropriate preparation and planning and a collaborative multi-disciplinary team approach, TAVR can be a treatment option for severe AR in patients with ccTGA at high risk for surgery.

Lead author biography

graphic file with name ytaa102f6.jpg

Takahiro Nomura is a Cardiologist. Specialty is ischaemic heart disease and structure heart disease.

Supplementary material

Supplementary material is available at European Heart Journal - Case Reports online.

Slide sets: A fully edited slide set detailing this case and suitable for local presentation is available online as Supplementary data.

Consent: The author/s confirm that written consent for submission and publication of this case report including image(s) and associated text has been obtained from the patient in line with COPE guidance.

Conflict of interest: E.M.Z. has been a proctor for Edwards Lifesciences and Medtronic; and a consultant and national principal investigator for Edwards Lifesciences. R.R.M. received grant support from the Edwards Lifesciences Corporation and St. Jude Medical, and is a consultant for Abbott Vascular, Cordis, and Medtronic; he holds equity in Entourage Medical. All other authors declare no potential conflicts of interest.

Supplementary Material

ytaa102_Supplementary_Slide_Set

References

  • 1. Wallis GA, Debich-Spicer D, Anderson RH.. Congenitally corrected transposition. Orphanet J Rare Dis 2011;6:22. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2. Graham TP, Bernard YD, Mellen BG, Celermajer D, Baumgartner H, Cetta F, Connolly HM, Davidson WR, Dellborg M, Foster E, Gersony WM, Gessner IH, Hurwitz RA, Kaemmerer H, Kugler JD, Murphy DJ, Noonan JA, Morris C, Perloff JK, Sanders SP, Sutherland JL.. Long-term outcome in congenitally corrected transposition of the great arteries. J Am Coll Cardiol 2000;36:255–261. [DOI] [PubMed] [Google Scholar]
  • 3. Mongeon FP, Connolly HM, Dearani JA, Li Z, Warnes CA.. Congenitally corrected transposition of the great arteries ventricular function at the time of systemic atrioventricular valve replacement predicts long-term ventricular function. J Am Coll Cardiol 2011;57:2008–2017. [DOI] [PubMed] [Google Scholar]
  • 4. Pino PG, Pergolini A, Zampi G, Calicchia A, Chialastri C, Orsini FM, Fini F, Buffa V, Minardi G.. Congenitally corrected transposition of the great arteries with severely stenotic bicuspid aortic valve in an adult: a case report. Echocardiography 2012;29:E13–E15. [DOI] [PubMed] [Google Scholar]
  • 5. Patnaik AN, Barik R, Nemani L, Saikh S.. Aortic balloon valvuloplasty in corrected transposition of the great arteries with severe valvular aortic stenosis of congenital bicuspid aortic valve. Ann Pediatr Card 2014;7:247–248. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6. Beauchesne LM, Warnes CA, Connolly HM, Ammash NM, Tajik AJ, Danielson GK.. Outcome of the unoperated adult who presents with congenitally corrected transposition of the great arteries. J Am Coll Cardiol 2002;40:285–290. [DOI] [PubMed] [Google Scholar]
  • 7. Vasa-Nicotera M, Sinning J-M, Chin D, Lim TK, Spyt T, Jilaihawi H, Grube E, Werner N, Nickenig G, Kovac J.. Impact of paravalvular leakage on outcome in patients after transcatheter aortic valve implantation. JACC Cardiovasc Interv 2012;5:858–865. [DOI] [PubMed] [Google Scholar]
  • 8. Sinning J-M, Hammerstingl C, Vasa-Nicotera M, Adenauer V, Lema Cachiguango SJ, Scheer A-C, Hausen S, Sedaghat A, Ghanem A, Müller C, Grube E, Nickenig G, Werner N.. Aortic regurgitation index defines severity of peri-prosthetic regurgitation and predicts outcome in patients after transcatheter aortic valve implantation. J Am Coll Cardiol 2012;59:1134–1141. [DOI] [PubMed] [Google Scholar]
  • 9. Yoon S-H, Schmidt T, Bleiziffer S, Schofer N, Fiorina C, Munoz-Garcia AJ, Yzeiraj E, Amat-Santos IJ, Tchetche D, Jung C, Fujita B, Mangieri A, Deutsch M-A, Ubben T, Deuschl F, Kuwata S, De Biase C, Williams T, Dhoble A, Kim W-K, Ferrari E, Barbanti M, Vollema EM, Miceli A, Giannini C, Attizzani GF, Kong WKF, Gutierrez-Ibanes E, Jimenez Diaz VA, Wijeysundera HC, Kaneko H, Chakravarty T, Makar M, Sievert H, Hengstenberg C, Prendergast BD, Vincent F, Abdel-Wahab M, Nombela-Franco L, Silaschi M, Tarantini G, Butter C, Ensminger SM, Hildick-Smith D, Petronio AS, Yin W-H, De Marco F, Testa L, Van Mieghem NM, Whisenant BK, Kuck K-H, Colombo A, Kar S, Moris C, Delgado V, Maisano F, Nietlispach F, Mack MJ, Schofer J, Schaefer U, Bax JJ, Frerker C, Latib A, Makkar RR.. Transcatheter aortic valve replacement in pure native aortic valve regurgitation. J Am Coll Cardiol 2017;70:2752–2763. [DOI] [PubMed] [Google Scholar]
  • 10. Blackman DJ, Saraf S, MacCarthy PA, Myat A, Anderson SG, Malkin CJ, Cunnington MS, Somers K, Brennan P, Manoharan G, Parker J, Aldalati O, Brecker SJ, Dowling C, Hoole SP, Dorman S, Mullen M, Kennon S, Jerrum M, Chandrala P, Roberts DH, Tay J, Doshi SN, Ludman PF, Fairbairn TA, Crowe J, Levy RD, Banning AP, Ruparelia N, Spence MS, Hildick-Smith D.. Long-term durability of transcatheter aortic valve prostheses. J Am Coll Cardiol 2019;73:537–545. [DOI] [PubMed] [Google Scholar]
  • 11. Søndergaard L, Ihlemann N, Capodanno D, Jørgensen TH, Nissen H, Kjeldsen BJ, Chang Y, Steinbrüchel DA, Olsen PS, Petronio AS, Thyregod HGH.. Durability of transcatheter and surgical bioprosthetic aortic valves in patients at lower surgical risk. J Am Coll Cardiol 2019;73:546–553. [DOI] [PubMed] [Google Scholar]
  • 12. Overtchouk P, Delhaye C, Sudre A, Modine T.. Successful transcatheter aortic valve implantation for severe aortic stenosis of a bicuspid valve with situs inversus totalis guided by advanced image processing: a case report. Eur Heart J Case Rep 2018;2:1–4. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13. Nascimbene A, Loyalka P, Gregoric ID, Bellera R, Malahfji M, Petrovic M, Kar B.. Transcatheter aortic valve implantation in a patient with unicuspid aortic valve. Tex Heart Inst J 2017;44:127–130. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

ytaa102_Supplementary_Slide_Set

Articles from European Heart Journal: Case Reports are provided here courtesy of Oxford University Press

RESOURCES