Abstract
Materials coming from renewable resources have drawn recently an increased attention in various applications as an eco-friendly alternative in the synthesis of novel functional materials. Polysaccharides, with their prominent representative – chitosan (CS), are well-known for their sorption properties, being able to remove metal ions from dilute solutions either by electrostatic interactions or chelation. In this context, we proposed here a comparative study on Cu2+, Zn2+, Ni2+, Fe3+, and Cr3+ metal ions removal from industrial wastewaters by CS-based composite cryogels using batch technique. The composite cryogels consisting of CS embedding a natural zeolite, namely clinoptilolite, were synthesized by cryogelation, and their sorption performance were compared to those of CS cryogels and of acid-activated zeolite. A deeper analysis of thermodynamics and kinetics sorption data was performed to get insights into the sorption mechanism of all metal ions onto sorbents. Based on the optimized sorption conditions, the removal of the above-mentioned ions from aqueous solutions by the composite sorbent using dynamic technique was also evaluated.
Keywords: chitosan, zeolite, cryogel sorbents, dynamic study, metal ions removal
1. Introduction
Industrial activities, such as mining operations, manufacturing of electronic devices, electroplating, chemical etching, and petro–chemistry, are mainly responsible for the release of heavy metal ions (HMIs) into the environment, which represents a serious threat to the human health, living entities and all the ecological systems. A broad variety of HMIs, including copper, nickel, cadmium, cobalt, zinc, iron, lead, or chromium can be detected into the industrial wastewaters, whose concentrations are much higher than those recommended by the environmental agencies.
Coagulation/flocculation, membrane filtration, electrochemical processes, electrodialysis, ion exchange, photocatalysis, and biological treatments [1,2] are some of the wastewater decontamination methods in continuous development for diminishing the harmful effect of the HMIs onto the ecosystem. However, these techniques have several major limitations, e.g., an incomplete metal ion removal, request of extra chemicals, production of large amounts of sludge, high operating costs, and so forth. To overcome these shortcomings, many studies have been focused on adsorption processes [1], due to its sustainability, low fouling problems, high efficiency, low energy consumption, easy operation, as well as less secondary pollution.
Various sorbents including activated carbon [3], carbon nanotubes [4], organic ion exchangers [5], zeolites [6,7,8,9], and polysaccharide-based hydrogels [10,11,12,13,14,15,16] have been tested for the treatment of HMIs-containing wastewaters. Among them, polysaccharides, such as chitosan (CS) [10,11,12], salecan [13], pullulan [14], alginate [15], and pectin [16], as biosorbents, are preferred because they possess several advantages such as high abundance, biodegradability, and nontoxicity, particularly suited for the removal of HMIs from polluted tap or groundwater. Among the available biopolymers, CS has the highest sorption performance toward HMIs [10,11,12] due to its abundant -NH2 and -OH groups. Its sorption capacity has been further improved by functionalization with diacetylmonoxime [17] and polyhexamethyleneguanidine [18] or grafting of malic acid [19] or glutamic acid [20] onto CS matrix. Nevertheless, CS has poor mechanical properties and exhibits low chemical stability in harsh aqueous environments such as HMIs-containing wastewaters. Consequently, crosslinking [21], blending with other natural or synthetic polymers [22,23,24,25], imprinting [26,27], or incorporating of reinforcing fillers such as magnetite [28,29], zeolites [22,30,31,32], or metal-organic frameworks [33] into the CS matrices have been explored to design composite materials endowed with enhanced sorption capacity, selectivity, and reusability performance, especially toward Cu2+ ions using simulated aqueous solutions. However, the real wastewaters consist of complex mixtures of HMIs in various concentrations. This highlights the necessity to evaluate the low-cost CS-based sorbents to remove Cu2+ ions from multicomponent mixtures with a much broader variety of HMIs.
The objectives of this study are (i) to use a composite based on clinoptilolite (CPL) particles entrapped within CS cryogels for the treatment of high-concentrated wastewaters containing Cu2+, Zn2+, Ni2+, Fe3+, and Cr3+ ions resulted from photoetching processes; (ii) to systematically evaluate the effects of several parameters such as the solution pH, sorbent dose, number of sorption/desorption cycles, contact time, and temperature on the sorption performance of CS-based composite cryogel in comparison to that of cross-linked CS cryogel and of acid-treated clinoptilolite (CPLH+) sorbents; (iii) to explain the sorption mechanism by fitting non–linear theoretical models onto experimental sorption kinetics data; (iv) to evaluate the sorption performance of CS-based composite cryogel in dynamic continuous mode.
2. Results and Discussion
Compared to powdery or flake CS, CS-based cryogels prepared by unidirectional freezing methodology have attractive advantages, including high porosity and large pore sizes (Figure 1), which may facilitate a fast diffusion of HMIs toward a large number of –NH2 and−OH functional groups of the sorbent (Figure 1G). The stable monolith shape of the CS-based sorbent (Figure 1D) ensures its easy separation. Therefore, cross-linked CS cryogels and CGCS_CPLH+ composite cryogels were tested as sorbents for Cu2+, Zn2+, Ni2+, Fe3+, and Cr3+ ions removal under competitive conditions. Their sorption performance as a function of several parameters were systematically investigated in comparison to CPLH+ sorbent. Some characteristics of the sorbents used in this study were collected in Figure 1.
The nitrogen adsorption-desorption BET isotherm of CPLH+ is categorized as a Type IV isotherm (Figure 1B), indicating the presence of mesopores [34]. The BET surface area and the pore volume of the CPH+ particles were determined as 24 m2·g−1, and 0.042 cm3·g−1 (Figure 1A). The CS-based sorbents have a well-patterned morphology (Figure 1C) with porous channels unidirectionally arranged with an average distance between them of about 27 µm for CGCS and of about 18 µm for CGCS_CPLH+. The presence of CPLH+ particles on the surface of CGCS_CPLH+ composite cryogel could be observed on the SEM micrograph (Figure 1C – red circles on the right SEM micrograph). The optical images in Figure 1D shows the monolith shape of the CGCS_CPLH+ composite sorbent, which is preserved after loading with HMIs. The CGCS_CPLH+ composite sorbent was colored in dark brown after sorption of HMIs from industrial wastewater (Figure 1D).
2.1. Sorption Properties of Cryogel-Based Sorbents in Bach Mode
2.1.1. Removal of Divalent Cations (Cu2+, Zn2+, and Ni2+) under Competitive Conditions
Cu2+, Zn2+, and Ni2+ ions were investigated for their affinity to the CGCS and CGCS_CPLH+ cryogel matrices in comparison to that of CPLH+ sorbent. Batch-mode sorption studies were performed under competitive conditions using five-component industrial wastewater. The concentration of each cation in the five–component wastewater was 230 mg·L−1 for Cu2+ ions, 63 mg·L−1 for Zn2+, 230 mg·L−1 for Ni2+, 230 mg·L−1 for Fe3+ ions, and 6 mg·L−1 for Cr3+ ions, respectively. The sorption properties of Cu2+ ions from this HMIs mixture, as a function of pH, sorbent dose, number of sorption/desorption cycles, and contact time are presented in Figure 2.
As Figure 2A shows, the amount of Cu2+ ions retained by CS–based cryogel sorbents (CGCS, and CGCS_CPLH+) significantly increased with the increase of pH from 1.5 to 5, and decreased afterwards. In the case of CPLH+ sorbent, only a slight increase of the qe values was observed in the studied pH range. At pH > 5, the precipitation of Cu(OH)2 occurs, and thus the qe values started to decrease. The influence of pH on the removal of Cu2+ ions by the CS-based cryogels is almost similar with that reported for other sorbents containing CS as matrix [19,20,23,24,29,30,35,36]. Based on the above results, the pH value of the wastewater was adjusted to 5 when the sorption of Cu2+ ions was further evaluated.
The sorbent dosage is also an important parameter for removal of Cu2+ ions [14,23,36]. Consequently, the Cu2+ removal from its mixture with Zn2+, Ni2+, Fe3+ and Cr3+ ions by CPLH+, CGCS, and CGCS_CPLH+ sorbents with different dosages was investigated. As presented in Figure 2B, we found that the amount Cu2+ retained (qe, mg·g−1) by sorbents decreased with the increase of sorbent dosage, while the removal efficiency (RE, %) increased with the increase of sorbent dosage. This behavior is associated with many sites/functional groups able to remove efficiently a high quantity of HMIs, while the number of HMIs distributed per sorbent mass unit decreased, accordingly, with the increase of the sorbent dose [14,23,36]. For instance, the saturated sorption capacity of CPLH+, CGCS, and CGCS_CPLH+ sorbents decreased from 15.01 mg·g−1, 63.54 mg·g−1 and respectively, 105.18 mg·g−1 to 7.23 mg·g−1, 25.54 mg·g−1, and respectively, 46.86 mg·g−1 (Figure 2B) when the sorbent dosage increased from 0.01 to 0.04 g. The RE values were around 12%, 40%, and 80% for CPLH+, CGCS, and respectively, CGCS_CPLH+ sorbents at a sorbent dose higher than 0.03 g. A RE value higher than 80% was achieved when the Cu2+ ions removal was studied using single-component aqueous systems [14,20,35,36]. Considering the RE values, the optimal sorbent dose of 0.035 g was chosen for all upcoming sorption experiments.
In this study, the HMIs retained on CS-based sorbents were successfully eluted with 0.1 M HCl solution. The regeneration in convenient conditions, the level of reusability, and the recovery of HMIs in a concentrated form are key factors, which should be taken under consideration when the feasibility of a sorbent is evaluated [23,35,36]. In this respect, the CSCS and CGCS_CPLH+ sorbents were further involved in successive sorption/desorption cycles (Figure 2C), after the adequate regeneration with 0.1 M NaOH. For the CGCS sorbent, a slight decrease of the qe values was observed after the 3rd sorption/desorption cycle. As can be seen from Figure 2C for the CGCS_CPLH+ sorbent, the qe values remained almost unchanged even after the 5th cycle of sorption/desorption, revealing its remarkable chemical stability under harsh conditions.
The effect of contact time on the sorption of Cu2+ onto the CPLH+, CGCS, and CGCS_CPLH+ sorbents was studied, and as it can be seen (Figure 2D) the sorption capacity shows a sharp increase from the beginning due to a high number of available active sites. Then, as the active sites are filled up there is a slow increase till the equilibrium state [24]. The optimum contact time was set at 180 min.
The removal of the other two competitive divalent cations, i.e., Zn2+ and Ni2+ ions by CPLH+, CGCS and CGCS_CPLH+ sorbents was also first investigated as a function of pH value of the multi-component industrial wastewater (Figure 3A,B).
As Figure 3 shows, at pH lower than 4, both divalent ions (Zn2+ and Ni2+) were less retained on the sorbents. The higher sorption capacity was obtained at pH 5 for Zn2+ ions and at pH 4.5 for Ni2+ ions. Further increase in pH leads to the precipitation of Zn2+ or Ni2+ hydroxide complexes which inhibits the sorption process. Compared to Cu2+ ions, the CPLH+, CGCS, and CGCS_CPLH+ sorbents showed a low affinity for the Zn2+ and Ni2+ ions (Figure 2 and Figure 3). In conclusion, the studies on the pH effect on the HMIs removal by CPLH+, CGCS, and CGCS_CPLH+ sorbents showed that the qe values increase with the increase of pH, up to an optimum pH for each metal ion, and was reduced thereafter. The explanation for this behavior is based on the ionic speciation in solution as a function of pH [35]. At pH values lower than 4, the competition between H+ and Cu2+, Zn2+, and Ni2+ ions for the sorption sites of the sorbents significantly diminished the sorption of HMIs on the surface of the CPLH+, CGCS, and CGCS_CPLH+ sorbents. In addition, at low pH the CS-based sorbents are positively charged, the protonation of -NH2 groups in acidic solution induces an electrostatic repulsion of HMIs that reduces the number of binding sites available for HMIs [20,23,29,37,38]. However, the Cu2+, Zn2+ and Ni2+ ions uptake increased as the pH increased to pH 5.0 and respectively to 4.5 (Figure 2 and Figure 3), as most active sites on the CS-based sorbents are deprotonated [23,35] resulting in a more net attractive force which is responsible for high HMIs removal from aqueous solution. In the case of CPLH+ sorbent, it was showed that the sorption of divalent cations (Cu2+, Ni2+ or Zn2+ ions) by ion exchange was also enhanced by increasing the initial pH of the solution. At acidic pH values, ion exchange sorption is reduced due to the competition of these ions and H+ ions for dynamic ion exchange sorption sites [7,9]. With decreasing H+ ions in the solution at higher pH values, the zeolite surface is deprotonated and subsequently the uptake of the metal ions is enhanced [7,9].
To understand the influence of contact duration on the sorption properties of HMIs on all sorbents, a series of experiments was performed at various times between 15 and 480 min (Figure 3C,D). The greatest rate of sorption was exhibited by CPLH+ sorbent and occurred within about 50 min for Zn2+ ions and 90 min for Ni2+ ions. This rapid sorption can be attributed to HMIs sorption by an ion exchange reaction on the surface sites rather than in the pores [7]. The sorption mechanism is associated with the rate-limiting step in a sorption process [23,24,35]. To get insights into the process dynamics and to determine the sorption rate of HMIs onto sorbents, pseudo-first order model (PFO) and pseudo-second order model (PSO) (Table 1) were employed.
Table 1.
Kinetic Modelsa |
; k1—Rate Constant of the PFO Kinetic Model, min−1 |
; k2—Rate Constant of the PSO Kinetic Model, g mg–1 × min–1 |
||||||
---|---|---|---|---|---|---|---|---|
Sorbents | Sorbents | |||||||
Metal Ions | CPLH+ | CGCS | CGCS_ CPLH+ |
CPLH+ | CGCS | CGCS_ CPLH+ |
||
Cu2+ | qe,calc | 8.97 | 35.80 | 57.15 | qe,calc | 8.14 | 29.42 | 50.77 |
k1 | 0.03 | 0.01 | 0.02 | k2 | 0.005 | 0.0004 | 0.0005 | |
R2 | 0.99 | 0.96 | 0.97 | R2 | 0.99 | 0.98 | 0.98 | |
χ2 | 0.08 | 5.79 | 8.71 | χ2 | 0.08 | 2.36 | 5.49 | |
Zn2+ | qe,calc | 0.36 | 2.84 | 5.46 | qe,calc | 0.32 | 2.27 | 4.73 |
k1 | 0.02 | 0.01 | 0.02 | k2 | 0.09 | 0.004 | 0.004 | |
R2 | 0.94 | 0.96 | 0.99 | R2 | 0.98 | 0.98 | 0.99 | |
χ2 | 0.0008 | 0.04 | 0.03 | χ2 | 0.0002 | 0.02 | 0.01 | |
Ni2+ | qe,calc | 0.16 | 0.75 | 1.47 | qe,calc | 0.13 | 0.69 | 1.34 |
k1 | 0.01 | 0.03 | 0.04 | k2 | 0.08 | 0.07 | 0.03 | |
R2 | 0.94 | 0.91 | 0.98 | R2 | 0.97 | 0.96 | 0.99 | |
χ2 | 0.0009 | 0.005 | 0.003 | χ2 | 0.002 | 0.002 | 0.001 |
aqe,calc is the calculated amount of HMIs adsorbed on sorbents, mg·g−1.
The experimental qe values for Cu2+ ions removal by CPLH+, CGCS, and CGCS_CPLH+ sorbents were 8.2 mg·g−1, 28.29 mg·g−1, and respectively, 51.15 mg·g−1 (Figure 2D). The experimental qe values for Zn2+ ions removal by CPLH+, CGCS, and CGCS_CPLH+ sorbents were 0.32 mg·g−1, 2.16 mg·g−1, and respectively, 4.71 mg·g−1 (Figure 3C). The experimental qe values for Ni2+ ions removal by CPLH+, CGCS, and CGCS_CPLH+ sorbents were 0.12 mg·g−1, 0.73 mg·g−1, and respectively, 1.38 mg·g−1 (Figure 3D). The high values of R2, the low values of χ2, and the negligible differences between the calculated (qe,calc) and the experimental capacities suggest that the PSO model is the predominant kinetic model for Cu2+, Zn2+, and Ni2+ ions removal by all sorbents (Figure 2D, Figure 3C,D, and Table 1). The obtained results are in agreement with the literature data regarding the sorption kinetic analysis of Cu2+, Zn2+, Ni2+ ions onto other CPL [6,7,8,9] or CS-based sorbents [18,20,23,24,36,39,40,41], which have been well fitted with PSO kinetic. According to a PSO model assumption the rate–determining step may be chemisorption, relating valence forces through sharing or exchange of electrons between HMIs and active sites [23,24].
2.1.2. Removal of Trivalent Cations (Fe3+ and Cr3+) under Competitive Conditions
The effect of pH, sorbent dose, number of sorption/desorption cycles, and contact time was also first systematically investigated for removal of Fe3+ ions from multicomponent industrial wastewaters using CPLH+, CSCG, and CSCG_CPLH+ sorbents (Figure 4).
As Figure 4A shows the sorption of Fe3+ increased with increasing pH of the solution, the optimum sorption pH being around 4.0. In the solution pH range 1 to 5, Fe3+ appeared as Fe3+, FeOH2+, Fe(OH)2+, Fe2(OH)24+, and Fe3(OH)45+ cationic species [35]. The presence of Fe(OH)2+ as major species at pH > 4, induced the decrease in the sorption capacity for these metal ions (Figure 4A). A similar behavior has been reported for the sorption of Fe3+ on other CS-based sorbents [35,42].
The increase of the sorbent dose (Figure 4B) led to the decrease of the qe values and to the increase of the RE values, as expected. For example, the saturated sorption capacity of CPLH+, CGCS, and CGCS_CPLH+ sorbents decreased from 5.38 mg·g−1, 48.78 mg·g−1 and respectively, 69.43 mg·g−1 to 2.58 mg·g−1, 16.74 mg·g−1, and respectively, 29.35 mg·g−1 when the sorbent dosage increased from 0.01 to 0.04 g. The RE values were around 4%, 29%, and 50% for CPLH+, CGCS, and respectively, CGCS_CPLH+ sorbents when the sorbent dose ranged from 0.03 g to 0.04 g (Figure 4B).
The Fe3+ ions retained on all sorbents were successfully desorbed with 0.1 M HCl solution, and after the regeneration with 0.1 M NaOH solution the CS-based sorbents were reused in six consecutive sorption/desorption cycles (Figure 4C). In the case of CGCS sorbent, the sorption capacity decreased after each sorption/desorption step indicating its low chemical stability. However, the CGCS_CPLH+ sorbent exhibited a remarkable chemical stability during the loading/leaching steps of Fe3+ ions, the sorption capacity remaining almost constant even after the 6th cycle.
The effect of the contact time on the Fe3+ ions retention capacity of the sorbents is shown in Figure 4D. The time necessary to reach sorption at equilibrium of Fe3+ ions from five-component aqueous solution was about 50 min for CPLH+, and about 120 min for CGCS and CGCS_CPLH+ sorbents (Figure 4D).
The sorption of Cr3+ ions onto CPLH+, CGCS and CGCS_CPLH+ sorbents was also strongly affected by the pH of the solution (Figure 5A).
As it was already observed for other HMIs, the sorption capacity of Cr3+ ions increased also with the increase of pH, the optimum sorption pH being located at 3.5 (Figure 5A). Besides the explanation included above for divalent cations, in the case of Cr3+ ions the results could be also associated with the speciation of Cr3+ ions in solutions. Thus, Cr3+ has been reported to exist as Cr3+, CrOH2+, Cr2(OH)24+ cationic species when the solution pH ranged from 1 to 5 [35]. The presence of Cr(OH)2+ as major species at pH > 3.5, induced the decrease in the sorption capacity for these metal ions (Figure 5A). An optimum sorption pH of 3.8 for Cr3+ ions has been also reported for CS flakes [12].
The effect of the contact time on the Cr3+ retention capacity of the CPLH+, CGCS, and CGCS_CPLH+ sorbents is presented in Figure 5B. The contact time varied in the range 0–480 min. As Figure 5B shows, the time required to achieve the equilibrium at pH 3.5 was about 120 min for all sorbents.
The sorption kinetics data of Fe3+ and Cr3+ ions onto CPLH+, CGCS, and CSCG_CPLH+ sorbents were also fitted by PFO and PSO models (Figure 4D and Figure 5B), and the obtained kinetic parameters are presented in Table 2.
Table 2.
Kinetic Models |
; k1—Rate Constant of the PFO Kinetic Model, min−1. |
; k2—Rate Constant of the PSO Kinetic Model, g mg–1 × min−1. |
|||||||
---|---|---|---|---|---|---|---|---|---|
Sorbents | Sorbents | ||||||||
Metal Ions | CPLH+ | CGCS | CGCS_ CPLH+ |
CPLH+ | CGCS | CGCS_ CPLH+ |
|||
Fe3+ | qe,calc | 3.72 | 24.51 | 46.63 | qe,calc | 2.95 | 19.68 | 40.27 | |
k1 | 0.01 | 0.01 | 0.02 | k2 | 0.003 | 0.0005 | 0.0004 | ||
R2 | 0.96 | 0.95 | 0.98 | R2 | 0.98 | 0.97 | 0.99 | ||
χ2 | 0.03 | 1.95 | 0.57 | χ2 | 0.06 | 3.65 | 4.81 | ||
Cr3+ | qe,calc | 0.02 | 0.05 | 0.07 | qe,calc | 0.02 | 0.03 | 0.06 | |
k1 | 0.03 | 0.01 | 0.01 | k2 | 2.08 | 0.2 | 0.17 | ||
R2 | 0.98 | 0.94 | 0.92 | R2 | 0.99 | 0.96 | 0.95 | ||
χ2 | 0.0002 | 0.0006 | 0.0003 | χ2 | 0.006 | 0.0002 | 0.0005 |
aqe,calc is the calculated amount of HMIs adsorbed on sorbents, mg g−1.
The experimental qe values for Fe3+ ions removal by CPLH+, CGCS, and CGCS_CPLH+ sorbents were 2.81 mg g−1, 18.64 mg g−1, and respectively, 39.64 mg g−1 (Figure 4D). The experimental qe values for Cr3+ ions removal by CPLH+, CGCS, and CGCS_CPLH+ sorbents were 0.015 mg·g−1, 0.035 mg·g−1, and respectively, 0.053 mg·g−1 (Figure 5B). As can be seen in Table 2, the kinetic data for the sorption of Fe3+ and Cr3+ ions onto all sorbents under study were well described by the PSO kinetic model, the values of R2 and of the χ2 being higher and respectively lower for these models than for the PFO kinetic model. These results support also a chemisorption mechanism for Fe3+ and Cr3+ ions sorption.
For a comparative evaluation, the sorption properties of CPLH+, CGCS, and CGCS_CPLH+ sorbents toward Cu2+, Zn2+, Ni2+, Fe3+ and Cr3+ ions were also investigated by carrying out equilibrium sorption experiments in single-component system (Figure S1). Langmuir, Freundlich, Sips, Temkin and Dubinin–Radushkevich (D–R) isotherm models [24,41,42,43] were further used to investigate the sorption at equilibrium of the systems and to define the maximum sorption capacity (qm, mg g−1) of CPLH+, CGCS, and CGCS_CPLH+ sorbents (Figure S1). The Langmuir isotherm model fitted the experimental sorption equilibrium data better than Freundlich isotherm model, revealing homogenous distribution of the chelating sites on the sorbents for a uniform interaction with HMIs (Tables S1–S3). The separation factor, RL, values revealed a favorably sorption process, and the higher values of Freundlich constant, KF, obtained for CGCS_CPLH+, irrespective of the investigated HMI, supported the capacity enhancement by addition of CPLH+ onto CGCS cryogel network. Parameter n indicated the strong sorption of Cu2+ and Fe3+ ions onto sorbents as it lies in the range 2–4 (Tables S1–S3), indicating chemisorption as the main mechanism of sorption process [24,44]. The values of the mean free energy of sorption, E (kJ mol−1), evaluated taking into account the D–R isotherm constant (Equation (10), Supporting Information) of Cu2+, Zn2+, Ni2+, Fe3+, and Cr3+ ions onto CPLH+ sorbent (Table S1) were ranging from 12.5 to 15.15 kJ mol−1, indicating a process which occurs by an ion exchange mechanism. In the case of CGCS_CPLH+ sorbent the values of E for removal of Cu2+ and Fe3+ ions were higher than 40 kJ mol−1, supporting a process which occurred by chemisorption (Table S3). The qDR values were in the same range as the values of qm obtained by fitting the Langmuir isotherm (Tables S1–S3), which supports the applicability of the D−R isotherm in describing the sorption process. Subsequently, the compatibility of the Sips isotherm model for all sorbents, sustained by the high values of R2, as well as the calculated values of qm, which were very close to the experimental ones, points out the homogeneous distribution of the active sites/functional groups onto the sorbent surface. The maximum theoretical sorption capacities of CSCS_CPLH+ composite sorbent according to Sips model toward Cu2+, Zn2+, Ni2+, Fe3+, and Cr3+ ions were 61.10 mg·g−1, 18.67 mg·g−1, 12.24 mg·g−1, 53.46 mg·g−1, and respectively, 0.85 mg·g−1 (Tables S1–S3). Table S4 includes the maximum sorption capacity of various sorbents for Cu2+, Zn2+, Ni2+, Fe3+, and Cr3+ ions removal in comparison to that of our investigated sorbents. NaCPL [6,8], MnO2-coated zeolite [7], aluminosilicates modified by N,N’-bis(3-triethoxysilylpropyl)thiocarbamide [45], CS flakes [12], cross-linked CS gels [42], glutamic-CS hydrogels [20], CS/starches-g-PAN cryobeads [23], or CS/poly(vinyl amine) composite beads [38] have been successfully employed for removal of Cu2+, Zn2+, Ni2+, Fe3+, or Cr3+ ions from single-component aqueous solutions (Table S4). It should be pointed out that their sorption properties depended on the initial metal ion concentration, pH, sorbent dose, presence of other competitive species or temperature at which the sorption was carried out.
2.1.3. Thermodynamic Studies
The temperature effect on the sorption of Cu2+, Zn2+, Ni2+, Fe3+, and Cr3+ ions from industrial wastewater onto CPLH+, CGCS, and CGCS_CPLH+ sorbents was studied at 293, 298, 303, 308, and 313 K for 6 h of contact time at 125 rpm. The results showed that the sorption capacity of all metal ions increased with temperature increment, indicating an endothermic in nature process. The distribution coefficient KD (L mg−1) was calculated by equation [35,43,46]:
(1) |
Gibbs free energy change (ΔG0, kJ mol−1), enthalpy change (ΔH0, J mol−1) and entropy change (ΔS0, kJ mol−1 K−1) were calculated using the following equations [35,43,46]:
(2) |
(3) |
The values of ΔH° and ΔS° were calculated from the slope and intercept of the plot lnK0 vs 1/T, respectively (Figure 6, Table 3).
Table 3.
Metal Ions | CGCS_CPLH+ | ||||||
---|---|---|---|---|---|---|---|
ΔH°, J mol−1 |
ΔS°, kJ mol−1 K−1 |
ΔG°, kJ·mol−1 | |||||
293 | 298 | 303 | 308 | 313 | |||
Cu2+ | 74.79 | 0.318 | −18.67 | −19.93 | −21.34 | −23.31 | −24.97 |
Zn2+ | 59.74 | 0.261 | −17.02 | −18.16 | −19.40 | −20.64 | −22.34 |
Ni2+ | 25.22 | 0.047 | −9.42 | −10.17 | −10.78 | −11.32 | −11.81 |
Fe3+ | 86.42 | 0.356 | −18.08 | −19.42 | −21.27 | −23.02 | −25.21 |
Cr3+ | 45.29 | 0.185 | −9.02 | −10.34 | −11.03 | −12.07 | −12.80 |
CGCS | |||||||
ΔH°, J·mol−1 |
ΔS°, kJ mol−1 K−1 |
ΔG°, kJ·mol−1 | |||||
293 | 298 | 303 | 308 | 313 | |||
Cu2+ | 34.42 | 0.171 | −15.61 | −16.65 | −17.37 | −18.33 | −19.04 |
Zn2+ | 83.76 | 0.329 | −12.88 | −14.44 | −16.03 | −17.82 | −19.45 |
Ni2+ | 46.86 | 0.176 | −4.89 | −5.74 | −6.78 | −7.67 | −8.34 |
Fe3+ | 37.31 | 0.476 | −14.24 | −15.19 | −16.10 | −16.90 | −17.80 |
Cr3+ | 104.93 | 0.188 | −7.83 | −9.09 | −10.03 | −10.91 | −11.61 |
CPLH+ | |||||||
ΔH°, J·mol−1 |
ΔS°, kJ mol−1 K−1 |
ΔG°, kJ·mol−1 | |||||
293 | 298 | 303 | 308 | 313 | |||
Cu2+ | 14.38 | 0.090 | −12.12 | −12.55 | −13.04 | −13.46 | −13.92 |
Zn2+ | 26.17 | 0.114 | −7.16 | −7.83 | −8.37 | −8.96 | −9.45 |
Ni2+ | 19.61 | 0.077 | −3.02 | −3.45 | −3.95 | −4.26 | −4.55 |
Fe3+ | 17.03 | 0.093 | −10.43 | −10.95 | −11.43 | −11.88 | −12.30 |
Cr3+ | 60.08 | 0.223 | −5.21 | −6.71 | −7.83 | −8.75 | −9.76 |
The negative values of ΔG° reveal the spontaneous nature and feasibility of the sorption process of Cu2+, Zn2+, Ni2+, Fe3+, and Cr3+ ions onto CPLH+, CGCS, and CGCS_CPLH+ sorbents. The higher the negative values, the more the favorable conditions for the ion sorption [24,35,47]. The positive ΔH° values confirmed that the process is endothermic in nature. The positive ΔS° values indicate increased randomness at the solid-solution interface during the sorption processes [24,35,47]. The adsorbate species displace the adsorbed water molecules and the latter gain more translational entropy than is lost by the former, resulting in prevalence of randomness in the system [24,35,46,48].
2.2. Sorption Properties of Cryogel-Based Sorbents in Dynamic Mode
The batch sorption experiments showed a great potential of the CGCS_CPLH+ composite sorbent in treating industrial wastewaters containing Cu2+, Zn2+, Ni2+, Fe3+, and Cr3+ ions. Therefore, its affinity against HMIs was preliminary evaluated in dynamic conditions. The obtained data are presented in Figure 7. The CGCS_CPLH+ composite sorbent exhibited a high selectivity toward Cu2+ ions, this HMI appeared in the effluent after ca. 110 bed volumes (Figure 7A).
The Cr3+ and Ni2+ ions have relatively low affinity toward the CGCS_CPLH+ composite sorbent and the breakthrough was situated at ca. 7.5 and 25 bed volumes for Cr3+ and Ni2+, respectively. Loading curves (Figure 7A) followed the same order as in the case of batch experiments under competitive conditions: Cu2+ > Fe3+ > Zn2+ > Ni2+ > Cr3+. The desorption of HMIs retained onto composite sorbent during fixed-bed column experiments was performed using 0.1 M HCl. As can be seen in Figure 7B, Cu2+, Fe3+, Zn2+, Ni2+ were completely desorbed at 30 bed volumes, while the Cr3+ ions recovery was only about 75%. As the sorption of the HMIs onto sorbents under dynamic conditions are more complex and are influenced by the bed height, feed flow rate, or initial HMIs concentration, future experiments will be dedicated to the investigation of the influence of these parameters onto HMIs removal from multicomponent systems.
3. Materials and Methods
3.1. Materials
Chitosan (CS), as powder, was purchased from Sigma-Aldrich Chemie GmbH (Schnelldorf, Germany). The average molecular weight and the deacetylation degree of CS were determined as 330 kDa and respectively, 85%. The clinoptilolite (CPL) was used as reinforcing filler within CS matrix and was acid-activated as previously shown [30]. Briefly, the CPL fraction with sizes in the 0.032–0.050 mm range was activated with 1M HCl aqueous solution at a CPL/solution ratio of 1:10 (v/v) for 24 h. Afterwards, the CPL particles were washed multiple times with water until no Cl− ions were detected into the washing solutions. The acid-treated CPL particles were dried for 2 h at 105 °C, then at 40 °C for 24 h more, in a vacuum oven. Glutaraldehyde (GA), as aqueous solution with a concentration of 25%, purchased from Sigma–Aldrich, was used as cross-linker. The high-concentrated wastewaters containing Cu2+, Zn2+, Ni2+, Fe3+, and Cr3+ ions resulted from industrial photoetching processes were provided by Exella Europe SRL, Manufacturing Company of Metal-based Products, located in Cluj–Napoca, Romania.
3.2. Methods
CS-based composite cryogel, as a monolith, was prepared in the presence of CPLH+ as reinforcing filler, by unidirectional freezing technique. Typically, the CPLH+ fraction (0.075 g) with particle sizes in the range of 0.032 and 0.050 mm was dispersed in 5 mL MilliQ water and then was added to 10 g of CS (3 wt.% in 2 wt.% CH3COOH solution). This mixture was kept under stirring for 60 min, and then GA solution (0.64 mL, 2.5 wt.%) was added drop–by–drop under vigorous stirring over 30 min. Finally, aliquots from this mixture were transferred into 5 mL syringes, sealed with Parafilm, and then unidirectional frozen in liquid nitrogen, as previously described [49]. The cross-linking reaction was conducted at −18 °C using a CC1-K6 Huber Cryostat for 24 h. Afterwards, the syringes were taken out and maintained at room temperature (RT) for 1 h. After thawing, the cryogels were pushed out of syringes, cut as monoliths of 2.5 cm height, and immersed in 200 mL MilliQ water to wash out the unreacted compounds. Finally, the samples were dried by lyophilization in a Martin Christ, Alpha 1-2LD device (Martin Christ Gefriertrocknungsanlagen GmbH, Osterode am Harz, Germany) for 48 h, at −57 °C and 0.045 mbars. A similar protocol was selected to synthesize, purify, and dry the cross-linked CS cryogel without CPLH+. Some characteristics of the samples used as sorbents are summarized in Figure 1. The porosity of cryogels was evaluated by the liquid displacement method [50]. Thus, 0.01 g of dried monoliths were immersed in a known volume of isopropanol (V1) for 5 min. After the monoliths removal, the volume of isopropanol was measured (V3). The porosity (P, %) was calculated by Equation (4) [50]:
(4) |
where V2 is the total volume of the monoliths impregnated with isopropanol.
The volume fraction of pores in cryogel sorbents (Vp) was also evaluated by Equation (5) [51]:
(5) |
where m is the weight of dry phase (CS + GA + CPL); d2 is the density of CS (0.6 g cm−3); VT is the total volume of the equilibrium swollen monolith (in water) and was calculated by Equation (6):
(6) |
where Dw is the diameter of the equilibrium swollen monolith; lw is the length of the equilibrium swollen monolith.
For the CPLH+ sorbent, the BET surface area (SBET) and the total pore volume were determined using a NOVA 2200e®Quantachrome automated gas sorption analyzer (Quantachrome Instruments, Boynton Beach, FL, USA). The NovaWin software version 11.02 (Quantachrome Instruments) was used to process the nitrogen sorption isotherm registered for CPLH+ (Figure 1B).
The average pore sizes of cryogel sorbents were estimated using the ImageJ 1.48v analyzing software (National Institutes of Health and the Laboratory for Optical and Computational Instrumentation, University of Wisconsin, USA) [52] from three independent micrographs taken using an environmental scanning electron microscope (Quanta 200, FEI Company, Hillsboro, OR, USA). The water uptake (WU, g g−1) was calculated by Equation (7), as previously described [52]:
(7) |
where Ww is the weight of swollen samples and Wd is the weight of the dried samples. All experiments were performed in triplicates and their average values were reported in Figure 1A.
3.3. Batch Sorption Studies
The sorption performance of all sorbents was performed under competitive conditions, i.e., using a five–component mixture of Cu2+, Zn2+, Ni2+, Fe3+, and Cr3+ metal ions by batch system. Several sorption experimental parameters, such contact time, pH, sorbent dose, and temperature were investigated to determine their effect on the sorption process. The effect of sorption time was investigated by varying this parameter between 15 and 480 min, while the other parameters were kept constant. For the study of the pH influence, the initial pH value of the HMIs-containing wastewater was adjusted between 1.5 and 5.5 with 0.1 M HCl or 0.1 M NaOH. The effect of sorbent dose on sorption capacity was investigated by varying the amounts of sample into the aqueous mixture of metal ions. The solutions were equilibrated for 6 h at 200 rpm. Sorption experiments were performed at different temperatures to evaluate the temperature effect. The temperature used in this experiment was kept constant at 293, 298, 303, 308, and 313 K. To investigate the sorbent reusability, the metal ions loaded onto CS–based sorbents were eluted with 0.1 M HCl aqueous solution (20 mL) for 6 h. Then, the CS–based sorbents were washed several times with distilled water and were regenerated with 0.1 M NaOH aqueous solution (20 mL) for 6 h. After this treatment, the sorbents were reused in another cycle of sorption.
In each experiment, the supernatants of the solution were filtered using a membrane filter and final concentrations were determined by Flame Atomic Absorption Spectrometry (FAAS) using a high-resolution ContrAA 300 Analytik Jena spectrometer (Analytik Jena, Jena, Germany) equipped with a xenon lamp as a continuum radiation source. During experiment an aspiration rate of about 5 mL min−1 was used. Measurements of each analyte were carried out in triplicate. The residual concentration of each metal ion was determined at the characteristic maximum wavelengths of 324 nm for Cu2+ ions, 213 nm for Zn2+ ions, 232 nm for Ni2+ ions, 248 nm for Fe3+ ions, and 357 nm for Cr3+ ions, respectively.
The amount of metal ion adsorbed at equilibrium (qe, mg g−1) on all sorbents was calculated as:
(8) |
Co – initial metal ion concentration, mg L−1; Ce – concentration of the metal ion in aqueous solution at equilibrium, mg L−1; V – volume of aqueous solution, L; m – sorbent dose, g.
The efficiency of metal ion removal (RE, %) from aqueous solution on all sorbents was calculates as:
(9) |
Co and Ce – the same meaning as in Equation (8).
3.4. Dynamic Sorption Studies
The five-component solution containing Cu2+, Zn2+, Ni2+, Fe3+, and Cr3+ metal ions was used in the dynamic sorption procedure. A small glass column calibrated with an internal diameter of 5 cm and length of 16 cm was adapted as the experiment column at RT. The swollen monolith of 2.5 cm height was placed in the column. The top of the column was connected to a Lambda Hiflow peristaltic pump (Lambda Laboratory Instruments, Brno, Czech Republic) to the liquid-processor, and thus providing a continuous flow of five-component solution at 1.33 mL min−1. A Lambda OMNICOLL Fraction Collector (Lambda Laboratory Instruments, Brno, Czech Republic) collected effluent samples, which were subsequently analyzed for the residual HMI concentrations, every 15 min. Elution of HMIs was performed by passing of 0.1 M HCl through the fixed-bed column with a flow velocity of 0.42 mL min−1.
4. Conclusions
The sorption performance of composite cryogels consisting of CS embedding a natural zeolite toward divalent (Cu2+, Zn2+, and Ni2+) and trivalent (Fe3+, and Cr3+) cations removal from industrial wastewaters was deeply investigated in this work in comparison to those of CS cryogels and of acid-activated zeolite. The effect of several parameters (sorbent dose, contact time, pH, initial metal ion concentration, and temperature) on the sorption properties has been clearly established. The optimum sorption pH for Cu2+, Zn2+, Ni2+, Fe3+, and Cr3+ cations removal under competitive conditions was 5.0, 5.0, 4.5, 4, and respectively, 3.5. The CSCS_CPLH+ composite cryogel exhibited the highest sorption capacity, the maximum theoretical sorption capacities of this composite sorbent according to Sips model toward Cu2+, Zn2+, Ni2+, Fe3+, and Cr3+ ions were 61.10 mg·g−1, 18.67 mg·g−1, 12.24 mg·g−1, 53.46 mg·g−1, and respectively, 0.85 mg·g−1. The modeling of kinetics, isotherm, and thermodynamic experimental data indicated a spontaneous chemisorption process for the sorption of all metal cations onto CS–based sorbents. The dynamic sorption studies showed that the CGCS_CPLH+ composite sorbent exhibited a high selectivity toward Cu2+ ions. The obtained results support the further application of the composite cryogel based on CS and CPLH+ for the treatment of industrial wastewaters.
Acknowledgments
This work was supported by a grant of Executive Unit for Financing Higher Education, Research, Development and Innovation (UEFISCDI) with the ID PN-III-P1-1.1-TE-2016–1697, and the project number TE117/2018.
Supplementary Materials
The following are available online, Figure S1: Sorption isotherms of Cu2+ ions at pH = 5 (a), Zn2+ ions at pH = 5 (b), Ni2+ ions at pH = 4.5 (c), Fe3+ ions at pH = 4 (d), and Cr3+ ions at pH = 3.5 (e) onto CPLH+, CGCS, and CGCS_CPLH+ sorbents (sorbent dose = 3.5 g L−1, V = 10 mL, T = 293 K, N = 125 rpm, t = 24 h, C0 = 50−1000 mg/L), Table S1: Values of the parameters for the fitted isotherm models onto CPLH+, Table S2: Values of the parameters for the fitted isotherm models onto CGCS, Table S3: Values of the parameters for the fitted isotherm models onto CGCS_CPLH+, Table S4: Comparison of the qm values of various sorbents obtained according to the best fitted isotherm model onto HMIs sorption data.
Author Contributions
Conceptualization, M.V.D.; Methodology, D.H., E.S.D. and M.V.D.; Investigation, D.H., E.S.D., M.I., and M.V.D.; Resources, D.H., E.S.D., M.I., and M.V.D; Writing—Original Draft Preparation, D.H. and M.V.D.; Writing—Review and Editing, D.H., E.S.D. and M.V.D; Funding Acquisition, M.V.D.; Project Administration, M.V.D.; All authors have read and agreed to the published version of the manuscript.
Funding
This research was funded by Executive Unit for Financing Higher Education, Research, Development and Innovation (UEFISCDI), grant number TE117/2018.
Conflicts of Interest
The authors declare no conflict of interest.
Footnotes
Sample Availability: The CPLH+, CGCS, and CGCS_CPLH+ sorbents are available from the authors.
References
- 1.Carolin C.F., Kumar P.S., Saravanan A., Joshib G.J., Naushad M. Efficient techniques for the removal of toxic heavy metals from aquatic environment: A review. J. Environ. Chem. Eng. 2017;5:2782–2799. doi: 10.1016/j.jece.2017.05.029. [DOI] [Google Scholar]
- 2.Giwa A., Dindi A., Kujawa J. Membrane bioreactors and electrochemical processes for treatment of wastewaters containing heavy metal ions, organics, micropollutants and dyes: Recent developments. J. Hazard. Mater. 2019;370:172–195. doi: 10.1016/j.jhazmat.2018.06.025. [DOI] [PubMed] [Google Scholar]
- 3.Tounsadi H., Khalidi A., Machrouhi A., Farnane M., Elmoubarki R., Elhalil A., Sadiq M., Barka N. Highly efficient activated carbon from Glebionis coronaria L. biomass: Optimization of preparation conditions and heavy metals removal using experimental design approach. J. Environ. Chem. Eng. 2016;4:4549–4564. doi: 10.1016/j.jece.2016.10.020. [DOI] [Google Scholar]
- 4.Bassyouni M., Mansi A.E., Elgabry A., Ibrahim B.A., Kassem O.A., Alhebeshy R. Utilization of carbon nanotubes in removal of heavy metals from wastewater: A review of the CNTs’ potential and current challenges. Appl. Phys. A Mater. 2020;126:38. doi: 10.1007/s00339-019-3211-7. [DOI] [Google Scholar]
- 5.Dragan E.S., Humelnicu D., Dinu M.V. Design of porous strong base anion exchangers bearing N,N-dialkyl 2–hydroxyethyl ammonium groups with enhanced retention of Cr(VI) ions from aqueous solution. React. Funct. Polym. 2018;124:55–63. doi: 10.1016/j.reactfunctpolym.2018.01.010. [DOI] [Google Scholar]
- 6.Mihaly–Cozmuta L., Mihaly–Cozmuta A., Peter A., Nicula C., Tutu H., Silipas D., Indrea E. Adsorption of heavy metal cations by Na-clinoptilolite: Equilibrium and selectivity studies. J. Environ. Manag. 2014;137:69–80. doi: 10.1016/j.jenvman.2014.02.007. [DOI] [PubMed] [Google Scholar]
- 7.Irannajad M., Haghighi H.K. Removal of Co2+, Ni2+, and Pb2+ by manganese oxide-coated zeolite: Equilibrium, thermodynamics, and kinetics studies. Clays Clay Miner. 2017;65:52–62. doi: 10.1346/CCMN.2016.064049. [DOI] [Google Scholar]
- 8.Rajic N., Stojakovic D., Jovanovic M., Zabukovec Logar N., Mazaj M., Kaucic V. Removal of nickel (II) ions from aqueous solutions using the natural clinoptilolite and preparation of nano-NiO on the exhausted clinoptilolite. Appl. Surf. Sci. 2010;257:1524–1532. doi: 10.1016/j.apsusc.2010.08.090. [DOI] [Google Scholar]
- 9.Sprynskyy M., Buszewski B., Terzyk A.P., Namiesnik J. Study of the selection mechanism of heavy metal (Pb2+, Cu2+, Ni2+, and Cd2+) adsorption on clinoptilolite. J. Colloid Interf. Sci. 2006;304:21–28. doi: 10.1016/j.jcis.2006.07.068. [DOI] [PubMed] [Google Scholar]
- 10.Guibal E., Vincent T., Navarro R. Metal ion biosorption on chitosan for the synthesis of advanced materials. J. Mater. Sci. 2014;49:5505–5518. doi: 10.1007/s10853-014-8301-5. [DOI] [Google Scholar]
- 11.Zhang L., Zeng Y., Cheng Z. Removal of heavy metal ions using chitosan and modified chitosan: A review. J. Mol. Liq. 2016;214:175–191. doi: 10.1016/j.molliq.2015.12.013. [DOI] [Google Scholar]
- 12.Pietrelli L., Francolini I., Piozzi A., Sighicelli M., Silvestro I., Vocciante M. Chromium (III) removal from wastewater by chitosan flakes. Appl. Sci. 2020;10:1925. doi: 10.3390/app10061925. [DOI] [Google Scholar]
- 13.Qi X., Liu R., Chen M., Li Z., Qin T., Qian Y., Zhao S., Liu M., Zeng Q., Shen J. Removal of copper ions from water using polysaccharide-constructed hydrogels. Carbohydr. Polym. 2019;209:101–110. doi: 10.1016/j.carbpol.2019.01.015. [DOI] [PubMed] [Google Scholar]
- 14.Zeng Q., Qi X., Zhang M., Tong X., Jiang N., Pan W., Xiong W., Li Y., Xu J., Shen J., et al. Efficient decontamination of heavy metals from aqueous solution using pullulan/polydopamine hydrogels. Int. J. Biol. Macromol. 2020;145:1049–1058. doi: 10.1016/j.ijbiomac.2019.09.197. [DOI] [PubMed] [Google Scholar]
- 15.Torres–Caban R., Vega–Olivencia C.A., Mina–Camilde N. Adsorption of Ni2+ and Cd2+ from water by calcium alginate/spent coffee grounds composite beads. Appl. Sci. 2019;9:4531. doi: 10.3390/app9214531. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Jakóbik–Kolon A., Mitko K., Bok-Badura J. Zinc sorption studies on pectin-based biosorbents. Materials. 2017;10:844. doi: 10.3390/ma10070844. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Elsayed N., Alatawi A., Monier M. Diacetylmonoxine modified chitosan derived ion-imprinted polymer for selective solid-phase extraction of nickel (II) ions. React. Funct. Polym. 2020;151:104570. doi: 10.1016/j.reactfunctpolym.2020.104570. [DOI] [Google Scholar]
- 18.Chen S., Li C., Hou T., Cai Y., Liang L., Chen L., Li M. Polyhexamethyleneguanidine functionalized chitosan nanofiber membrane with superior adsorption and antibacterial performances. React. Funct. Polym. 2019;145:104379. doi: 10.1016/j.reactfunctpolym.2019.104379. [DOI] [Google Scholar]
- 19.Zhang Y., Lin S., Qiao J., Kołodyńska D., Ju Y., Zhang M., Cai M., Deng D., Dionysiou D.D. Malic acid-enhanced chitosan hydrogel beads (mCHBs) for the removal of Cr(VI) and Cu(II) from aqueous solution. Chem. Eng. J. 2018;353:225–236. doi: 10.1016/j.cej.2018.06.143. [DOI] [Google Scholar]
- 20.Abdelwahab H.E., Hassan S.Y., Mostafa M.A., El Sadek M.M. Synthesis and characterization of glutamic-chitosan hydrogel for copper and nickel removal from wastewater. Molecules. 2016;21:684. doi: 10.3390/molecules21060684. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Yang Z., Chai Y., Zeng L., Gao Z., Zhang J., Ji H. Efficient removal of copper ion from wastewater using a stable chitosan gel material. Molecules. 2019;24:4205. doi: 10.3390/molecules24234205. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Dragan E.S., Dinu M.V. Advances in porous chitosan-based composite hydrogels: Synthesis and applications. React. Funct. Polym. 2020;146:104372. doi: 10.1016/j.reactfunctpolym.2019.104372. [DOI] [Google Scholar]
- 23.Dragan E.S., Apopei Loghin D.F. Fabrication and characterization of composite cryobeads based on chitosan and starches-g-PAN as efficient and reusable biosorbents for removal of Cu2+, Ni2+, and Co2+ ions. Int. J. Biol. Macromol. 2018;120:1883–1972. doi: 10.1016/j.ijbiomac.2018.10.007. [DOI] [PubMed] [Google Scholar]
- 24.Trikkaliotis D.G., Christoforidis A.K., Mitropoulos A.C., Kyzas G.Z. Adsorption of copper ions onto chitosan/poly(vinyl alcohol) beads functionalized with poly(ethylene glycol) Carbohydr. Polym. 2020;234:115890. doi: 10.1016/j.carbpol.2020.115890. [DOI] [PubMed] [Google Scholar]
- 25.Contreras-Cortés A.G., Almendariz-Tapia F.J., Gómez-Álvarez A., Burgos-Hernández A., Luque-Alcaraz A.G., Rodríguez-Félix F., Quevedo-López M.Á., Plascencia-Jatomea M. Toxicological assessment of cross-linked beads of chitosan-alginate and Aspergillus australensis biomass, with efficiency as biosorbent for copper removal. Polymers. 2019;11:222–238. doi: 10.3390/polym11020222. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Dinu M.V., Dinu I.A., Lazar M.M., Dragan E.S. Chitosan-based ion-imprinted cryo-composites with excellent selectivity for copper ions. Carbohydr. Polym. 2018;186:140–149. doi: 10.1016/j.carbpol.2018.01.033. [DOI] [PubMed] [Google Scholar]
- 27.Monier M., Bukhari A.A.H., Elsayed N.H. Designing and characterization of copper (II) ion-imprinted adsorbent based on isatin functionalized chitosan. Int. J. Biol. Macromol. 2020;155:795–804. doi: 10.1016/j.ijbiomac.2020.03.215. [DOI] [PubMed] [Google Scholar]
- 28.Rafiee F., Karder R. Synthesis and characterization of magnetic glycocyamine-modified chitosan as a biosupport for the copper immobilization and its catalytic activity investigation. React. Funct. Polym. 2020;146:104434. doi: 10.1016/j.reactfunctpolym.2019.104434. [DOI] [Google Scholar]
- 29.Hamza M.F., Aly M.M., Abdel-Rahman A.A.H., Ramadan S., Raslan H., Wang S., Vincent T., Guibal E. Functionalization of magnetic chitosan particles for the sorption of U(VI), Cu(II) and Zn(II)—Hydrazide derivative of glycine-grafted chitosan. Materials. 2017;10:539. doi: 10.3390/ma10050539. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Dragan E.S., Dinu M.V., Timpu D. Preparation and characterization of novel composites based on chitosan and clinoptilolite with enhanced adsorption properties for Cu2+ Bioresour. Technol. 2010;101:812–817. doi: 10.1016/j.biortech.2009.08.077. [DOI] [PubMed] [Google Scholar]
- 31.Djelad A., Morsli A., Robitzer M., Bengueddach A., di Renzo F., Quignard F. Sorption of Cu(II) ions on chitosan-zeolite X composites: Impact of gelling and drying conditions. Molecules. 2016;21:109. doi: 10.3390/molecules21010109. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Bandura L., Franus M., Madej J., Kołodynska D., Hubicki Z. Zeolites in phenol removal in the presence of Cu(II) ions—Comparison of sorption properties after chitosan modification. Materials. 2020;13:643. doi: 10.3390/ma13030643. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Li D., Tian X., Wang Z., Guan Z., Li X., Qiao H., Ke H., Luo L., Wei Q. Multifunctional adsorbent based on metal-organic framework modified bacterial cellulose/chitosan composite aerogel for high efficient removal of heavy metal ion and organic pollutant. Chem. Eng. J. 2020;383:123127. doi: 10.1016/j.cej.2019.123127. [DOI] [Google Scholar]
- 34.ALOthmanA Z.A. Review: Fundamental aspects of silicate mesoporous materials. Materials. 2012;5:2874–2902. doi: 10.3390/ma5122874. [DOI] [Google Scholar]
- 35.Humelnicu D., Lazar M.M., Ignat M., Dinu I.A., Dragan E.S., Dinu M.V. Removal of heavy metal ions from multi-component aqueous solutions by eco-friendly and low-cost composite sorbents with anisotropic pores. J. Hazard. Mater. 2020;381:120980. doi: 10.1016/j.jhazmat.2019.120980. [DOI] [PubMed] [Google Scholar]
- 36.Dinu M.V., Dinu I.A., Lazar M.M., Dragan E.S. Insights into the mechanism of Cu2+ binding onto chitosan-based cryogel composites: Equilibrium, kinetics and thermodynamics studies. Cellulose Chem. Technol. 2018;52:181–192. [Google Scholar]
- 37.Fan L., Luo C., Lv Z., Lu F., Qiu H. Preparation of magnetic modified chitosan and adsorption of Zn2+ from aqueous solutions. Colloid Surf. B. 2011;88:574–581. doi: 10.1016/j.colsurfb.2011.07.038. [DOI] [PubMed] [Google Scholar]
- 38.Cocarta A.I., Gutanu V., Dragan E.S. Comparative sorption of Co2+, Ni2+ and Cr3+ onto chitosan/poly(vinyl amine) composite beads. Cellulose Chem. Technol. 2015;49:775–782. [Google Scholar]
- 39.Jamnongkan T., Singcharoen K. Towards novel adsorbents: The ratio of PVA/chitosan blended hydrogels on the copper (II) ion adsorption. Energy Procedia. 2016;89:299–306. doi: 10.1016/j.egypro.2016.05.038. [DOI] [Google Scholar]
- 40.Yu R., Shi Y., Yang D., Liu Y., Qu J., Yu Z.Z. Graphene oxide/chitosan aerogel microspheres with honeycomb-cobweb and radially oriented microchannel structures for broad-spectrum and rapid adsorption of water contaminants. ACS Appl. Mater. Inter. 2017;9:21809–21819. doi: 10.1021/acsami.7b04655. [DOI] [PubMed] [Google Scholar]
- 41.Zarghami S., Mohammadi T., Kazemimoghadam M. Adsorption behavior of Cu(II) ions on crosslinked chitosan/polyvinyl alcohol ion imprinted membrane. J. Disper. Sci. Technol. 2015;36:190–195. doi: 10.1080/01932691.2014.894916. [DOI] [Google Scholar]
- 42.Wan Ngah W.S., Ab Ghani S., Kamari A. Adsorption behaviour of Fe(II) and Fe(III) ions in aqueous solution on chitosan and cross-linked chitosan beads. Bioresour. Technol. 2005;96:443–450. doi: 10.1016/j.biortech.2004.05.022. [DOI] [PubMed] [Google Scholar]
- 43.Tran H.N., Jou S.J., Bandegharaei A.H., Chao H.P. Mistakes and inconsistencies regarding adsorption of contaminants from aqueous solutions: A critical review. Water Res. 2017;120:88–116. doi: 10.1016/j.watres.2017.04.014. [DOI] [PubMed] [Google Scholar]
- 44.Lujaniene G., Semcuk S., Lecinskyte A., Kulakauskaite I., Mazeika K., Valiulis D., Pakstas V., Skapas M., Tumenas S. Magnetic graphene oxide based nano-composites for removal of radionuclides and metals from contaminated solutions. J. Environ. Radioact. 2017;166:166–174. doi: 10.1016/j.jenvrad.2016.02.014. [DOI] [PubMed] [Google Scholar]
- 45.Pomazkina O.I., Filatova E.G., Pozhidaev Y.N. Adsorption of Ni(II), Cu(II), and Zn(II) ions by natural alumosilicate modified with N,N′-bis(3-triethoxysilylpropyl)thiocarbamide. Prot. Met. Phys. Chem. Surf. 2017;53:416–421. doi: 10.1134/S2070205117030182. [DOI] [Google Scholar]
- 46.Zhou X., Zhou X. The unit problem in the thermodynamic calculation of adsorption using the Langmuir equation. Chem. Eng. Comm. 2014;201:1459–1467. doi: 10.1080/00986445.2013.818541. [DOI] [Google Scholar]
- 47.Li L., Wang Z., Ma P., Bai H., Dong W., Chen M. Preparation of polyvinyl alcohol/chitosan hydrogel compounded with graphene oxide to enhance the adsorption properties for Cu(II) in aqueous solution. J. Polym. Res. 2015;22:150. doi: 10.1007/s10965-015-0794-3. [DOI] [Google Scholar]
- 48.Vatanpour V., Salehi E., Sahebjamee N., Ashrafi M. Novel chitosan/polyvinyl alcohol thin membrane adsorbents modified with detonation nanodiamonds: Preparation, characterization, and adsorption performance. Arab. J. Chem. 2020;13:1731–1740. doi: 10.1016/j.arabjc.2018.01.010. [DOI] [Google Scholar]
- 49.Lazar M.M., Dinu I.A., Silion M., Dragan E.S., Dinu M.V. Could the porous chitosan based composite materials have a chance to a “NEW LIFE” after Cu(II) ion binding. Int. J. Biol. Macromol. 2019;131:134–146. doi: 10.1016/j.ijbiomac.2019.03.055. [DOI] [PubMed] [Google Scholar]
- 50.Kaczmarek B., Sionkowska A., Osyczka A.M. The comparison of physic-chemical properties of chitosan/collagen/hyaluronic acid composites with nano-hydroxyapatite cross-linked by dialdehyde starch and tannic acid. Polym. Test. 2017;62:171–176. doi: 10.1016/j.polymertesting.2017.06.027. [DOI] [Google Scholar]
- 51.Dinu M.V., Přádný M., Dragan E.S., Michálek J. Morphogical and swelling properties of porous hydrogels based on poly(hydroxyethyl methacrylate) and chitosan modulated by ice-templating process and porogen leaching. J. Polym. Res. 2013;20:285. doi: 10.1007/s10965-013-0285-3. [DOI] [Google Scholar]
- 52.Dinu M.V., Lazar M.M., Dragan E.S. Dual ionic cross-linked alginate/clinoptilolite composite microbeads with improved stability and enhanced sorption properties for methylene blue. React. Funct. Polym. 2017;116:31–40. doi: 10.1016/j.reactfunctpolym.2017.05.001. [DOI] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.