Abstract
During the last decade high-throughput in vitro absorption, distribution, metabolism and excretion (HT-ADME) screening has become an essential part of any drug discovery effort of synthetic molecules. The conduct of HT-ADME screening has been “industrialized” due to the extensive development of software and automation tools in cell culture, assay incubation, sample analysis and data analysis. The HT-ADME assay portfolio continues to expand in emerging areas such as drug-transporter interactions, early soft spot identification, and ADME screening of peptide drug candidates. Additionally, thanks to the very large and high-quality HT-ADME data sets available in many biopharma companies, in silico prediction of ADME properties using machine learning has also gained much momentum in recent years. In this review, we discuss the current state-of-the-art practices in HT-ADME screening including assay portfolio, assay automation, sample analysis, data processing, and prediction model building. In addition, we also offer perspectives in future development of this exciting field.
Keywords: In vitro, HT-ADME, Automation, Bioanalysis, Mass spectrometry, Acoustic ejection mass spectrometry
Graphical abstract

Highlights
-
•
In vitro HT-ADME screening has become an essential part of small molecule drug discovery.
-
•
New technologies in automation, software and mass spectrometry have dramatically increased the efficiency of HT-ADME.
-
•
The field is poised for expansion in areas such as HT-ADME for new modality drugs and predictive ADME models.
1. Introduction
High-throughput in vitro ADME (absorption, distribution, metabolism and excretion) screening (HT-ADME) has been widely adopted as an essential part of lead optimization for synthetic molecules (small molecules and more recently peptides) since around the year 2000 [[1], [2], [3]]. HT-ADME screening usually consists of in vitro assay suites that assess compound properties (or liabilities) such as metabolism [4,5], permeability [[6], [7], [8]], drug-drug-interactions [[9], [10], [11]], physicochemical properties [12,13] and also toxicities [14,15]. Several key technologies, including automated liquid handling [16], high speed liquid chromatography–tandem mass spectrometry (LC-MS/MS) for sample analysis [17,18], and software and automation tools [[19], [20], [21]], have together enabled these in vitro assays to be performed in high-density plate format (96, 384 or even 1536-well plates [22]) with the throughput and capacity required for early phases of drug discovery. It has been proven with industry-wide data that addressing ADME properties early in the discovery process helps significantly reduce attrition rates of drug candidates due to pharmacokinetic properties later in development [23]. There have been a number of comprehensive reviews covering the history and common practices of HT-ADME screening and sample analysis [17,[24], [25], [26], [27], [28]].
Due to its critical role in drug discovery, the last decade (2010–2019) saw a number of significant developments in HT-ADME screening. First of all, the conduct of ADME screening has been “industrialized” through the development of software and automation that has facilitated assay incubation, sample analysis, data review and reporting. While in vitro ADME screening used to be conducted almost exclusively at big pharmaceutical companies, these mostly off-the-shelf tools have really “industrialized” ADME screening, empowering labs of different sizes, operating models (centralized, distributed, outsourced, etc.) and geographic locations to perform these screening assays with high efficiency. Secondly, cutting edge liquid handling and analysis technologies continued to be incorporated into ADME screening to further improve speed, quality and cost-effectiveness. Thirdly, the ADME screening assay portfolio continued to expand, especially in areas such as drug-transporter interactions, early soft spot identification, and ADME screening of peptide drug candidates. And lastly, the data generated by ADME screening assays have been widely used to develop in silico models with machine learning approaches to predict ADME properties. In this review we cover the recent developments and the state-of-the-art in these aforementioned areas; in addition we also offer a perspective on emerging sciences and technologies for next decade in the field of ADME screening.
2. The “industrialization” of ADME screening
At the time of its inception in the late 1990’s, in vitro ADME screening was almost exclusively performed at large pharmaceutical companies, where the significant size of the discovery portfolio ensured enough assay demand, therefore justifying the substantial investment required in infrastructure and expertise development [24,[29], [30], [31]]. There were no existing commercially-available solutions to HT-ADME automation and sample analysis at the time; therefore, many companies developed their own customized solutions. The assay automation of that era tended to be stand-alone, workstation-based, with limited integration of various components [29,32]. Similarly, various custom solutions were developed for automated LC-MS/MS method development, sample analysis and data review [[33], [34], [35], [36]]. While these highly innovative solutions laid the foundation for the field of HT-ADME screening as we know today, they required a high level of expertise in automation and bioanalysis to develop and maintain. The proprietary nature of these solutions also prevented them from being used in any other companies. As a result, HT-ADME screening was very much a “luxury” enjoyed by drug discovery organizations in only a handful of the largest pharmaceutical companies at the time.
From 2010 to 2019, with the importance of ADME screening in drug discovery well understood, and also thanks to the maturation of the underlying technologies, vendors started to commercialize products based on these previously proprietary tools specifically designed for HT-ADME screening.
2.1. Assay automation
In assay automation, multiple vendors including Tecan, Hamilton, PerkinElmer and many others, now offer complete, off-the-shelf solutions for ADME screening assays [4,16,37]. These solutions are typically based on a core platform of liquid handling, with additional accessories such as plate stores, shakers, incubators, filtration devices, centrifuges and sealers to perform tasks necessary for various HT-ADME assays. Several other vendors, including HighRes Biosolutions [38] and Agilent [39], offer fully integrated automation systems consisting of all of the aforementioned components, as well as one (or more) robotic arm(s) and corresponding software schedulers, for fully automated, truly walk-away assay operation. Multiple plates and multiple assays can be scheduled and conducted on the same system, thus realizing the most operation efficiency.
2.2. LC-MS/MS bioanalysis
LC-MS/MS with step or ballistic gradient LC, coupled with selected reaction monitoring (SRM) on triple-quadrupole mass spectrometers, has been the method of choice for HT-ADME sample analysis [40]. As pointed out by our previous review, the key challenges there are the large number of compounds requiring MS/MS optimization, the large sample number requiring analysis, and the large amount of data to process and review [17]. To address the requirement of SRM MS/MS conditions, automated optimization through flow injection analysis (FIA) is usually the solution [41]. To speed up the LC-MS/MS sample analysis, several approaches have been developed. The first is multiplexed LC-MS/MS, where multiple independent LC systems (channels) are connected through a switching valve to a single mass spectrometer; staggered injections are then made in synchronization with the switching valve, so that at any given time only the elution window from a single channel goes into the mass spectrometer. Either a 2x (for a 2-channel system) or a 4x (for a 4-channel system) speed improvement is possible with the multiplexing approach [13,42]. Another commonly used approach is direct online solid phase extraction – mass spectrometry (online SPE-MS), often also called “trap and elute”, where small SPE cartridges packed with quite large particles (∼50 μm) are used to perform essentially a desalting step for the sample first, and the analytes are then eluted with 100% organic solvent directly into the mass spectrometer [9,43,44]. The online SPE-MS approach offers a higher speed (5–10 s/sample) than the multiplexed LC-MS approach (30–60 s/sample), but obviously affords less chromatographic separation. Therefore, online SPE-MS is typically used for probe-based assays (i.e., Cytochrome P450 inhibition), where a single analyte and its stable isotopically labeled internal standard are analyzed for a large number of samples. On the other hand, multiplexed LC-MS/MS is commonly used in assays where many different compounds, all with different physicochemical properties, need to be analyzed from a single assay batch (i.e., from metabolic stability or permeability assays).
Recently, similar to automation solutions, several vendors now offer complete hardware and software packages for the LC-MS/MS sample analysis of HT-ADME assay samples using these aforementioned approaches. For example, Thermo offers the QuickQuan™ package where MS/MS optimization, method generation and sample analysis can be fully automated on their triple-quadrupole instruments [5,45,46]. Optionally, QuickQuan can be further integrated with the Thermo multiplexed frontend LC system (Aria) to achieve an analysis time as fast as 15 s/sample with gradient elution, which is desirable for the large number of samples encountered in HT-ADME screening [42,47].
Another vendor, Sciex, offers a highly integrated solution for HT-ADME analysis named DiscoveryQuant™. Originally based on a proprietary solution developed at Pfizer [48], DiscoveryQuant™ underwent multiple iterations of development as a collaboration project between Sciex and multiple partners in the biopharma industry, and has now evolved into the most widely adopted software tool for HT-ADME bioanalysis [21,49,50]. The automated SRM MS/MS optimization routine in DiscoveryQuant™ has two unique and very useful features. First, it uses only a single loop injection (∼1 min) with nested MS(/MS) scans to perform optimization of precursor ion, product ion, de-clustering voltage and collision energy, which has greatly simplified the optimization process and increased the optimization speed. Secondly, DiscoveryQuant™ has a powerful database feature where all optimized conditions from one instrument can be uploaded to a centralized database that allows sharing among many different Sciex instruments across the hall, or even across the globe, as illustrated in Fig. 1. A closely-related product, LeadScape™, not only incorporates all DiscoveryQuant™ features, but also controls the Apricot Designs Dual Arm (ADDA) [51] or LeadScape-1 (LS-1) [52] multiplexed autosampler for high-speed online-SPE or gradient LC separation in front of Sciex mass spectrometers. The online SPE-MS approach can achieve an analysis speed as fast as 5 s/sample, whereas the gradient LC mode can have a speed of approximately 15 s on the ADDA/LS-1 platform. Once the data are acquired, DiscoveryQuant™/LeadScape™ also has a data review module to perform automatic peak integration. Additional data review tools, including MultiQuant™ by Sciex and Gubbs Mass Spec Utility (GMSU) by Gubbs Inc, have also been widely used to process LC-MS/MS data from HT-ADME samples.
Fig. 1.
Centralized SRM database allows sharing of MS/MS conditions across multiple sites and instrument platforms using DiscoveryQuant™. SRM: selected reaction monitoring. Instrument pictures are used with permission from Sciex.
Taken together, these off-the-shelf and scalable solutions greatly enabled HT-ADME workflows in labs in biopharmaceutical companies of various sizes [9,43,[53], [54], [55]], in contract research organizations (CRO’s) [56] and in academic research centers [57,58]. Therefore, HT-ADME screening has evolved from a workflow done by only a few large pharmaceutical companies in the 2000’s to a standard practice anywhere where drug discovery research is conducted during the last decade.
3. Cutting-edge technologies in HT-ADME screening
In parallel to the industrialization of routine HT-ADME screening, novel and cutting-edge technologies have also continued to be tested and implemented in the field during the last decade thanks to the innovative culture of the existing HT-ADME community of practitioners. In this section, we review some of the technologies that have been adopted or are currently being evaluated in the HT-ADME screening laboratory.
3.1. Liquid handling
Liquid handling of sub-μL volumes has become a truly enabling technology for all screening communities (lead discovery, HT-ADME, etc.) in drug discovery. Low volume dispensing is critical in limiting the percentage of organic solvent (0.5% or lower) in the assay mixture, and the ability to accurately and reproducibly dispense nanoliter volumes can pave the way to assay miniaturization by reducing total incubation volume (and therefore reagent consumption). There are many technologies capable of nanoliter dispensing, with two enjoying the most success to date.
The mosquito® line of liquid handlers by SPT Labtech uses disposable, miniaturized positive displacement pipette tips to accurately transfer volumes as low as 25–50 nL. Since it uses a positive displacement approach for pipetting, a mosquito® liquid handler can easily transfer different liquid types, without resorting to re-calibration based on viscosity. Successful applications of mosquito® liquid handlers for low volume dispensing in HT-ADME assays have been reported [59].
Another highly successful nanoliter transfer approach uses sound waves to acoustically separate nanoliter-sized droplets from liquid meniscus in the source plate and eject them to the destination plate. Highly accurate, reproducible and rapid transfer of liquid volumes as low as 2.5 nL can be achieved in only several minutes for a 384-well plate [60]. First adopted in the high-throughput screening [61] and compound management [62] environment, acoustic transfer technologies have now been applied extensively in HT-ADME screening assays, especially those requiring serial dilutions for IC50 determination [25]. One caveat of the acoustic transfer approach is the need for calibration for each liquid type since different sound energy levels need to be applied for liquids with different properties (surface tension, viscosity, etc.). Two vendors currently offer acoustic dispensers: Echo by Labcyte®, and ATS® by EDC Biosystems. A comparison of the two low-volume transfer approaches is presented in Table 1.
Table 1.
Comparison of the two low-volume liquid handlers.
| Parameters | Positive displacement | Acoustic transfer |
|---|---|---|
| Transfer range | 25 nL to 1.2 μL | 2.5 nL to 5 μL |
| Sample contact | Contact | Contactless |
| Transfer speed | Minutes per 384-well plate | Minutes per 384-well plate |
| Consumables | Special tips | Special plates |
| Sample type | Any liquids | Aqueous, DMSO |
3.2. High-throughput sample analysis approaches
Sample analysis is another area where emerging technologies have been continuously evaluated and implemented. As mentioned previously, LC-MS/MS is still the workhorse in HT-ADME bioanalysis. However, it has been very difficult to break the 1 s/sample barrier for any chromatography and autosampler-based systems, despite the development of online SPE [44,63] and multiplexed LC systems [46]. To achieve even higher throughput, direct MS analysis from samples deposited onto solid support using various ionization methods has been attempted. These ionization methods include matrix assisted laser desorption ionization (MALDI) [64], laser diode thermal desorption (LDTD) [65], direct analysis in real time (DART) [66], coated blade spray [67], and dip-and-go inductive nanoelectrospray [68] amongst others. As pointed out in a previous review [17], although many of these ionization methods can achieve (or potentially achieve) a very high speed of analysis (several samples per second), they require an additional liquid handling step to transfer liquid assay samples into a solid support, which adds cost and complexity in automation. This disadvantage can be mitigated by using the aforementioned nanoliter transfer technologies for sample transfer [69], with several examples of HT-ADME applications reported in the literature [70]. Another disadvantage of these direct ionization approaches is the moderate to severe ionization suppression effect observed [71] (since there is no chromatographic separation), and the resulting generally lower data quality when compared to LC-MS-based approach.
A very innovative approach combining acoustic ejection and direct ionization for high-throughput mass spectrometry (HTMS) analysis has been recently developed by a group from AstraZeneca [72,73]. Dubbed acoustic mist ionization mass spectrometry, this approach uses a modified Echo acoustic dispenser to eject a “mist” of picoliter-sized droplets through a heated transfer tube directly into the mass spectrometer. Ionization is accomplished by a high voltage applied to the well top. The direct, contactless and high-speed (<1s/sample) features of this technology make it a highly attractive HTMS option for various screening areas and the group has published several papers describing its use in lead discovery. The biggest challenge of the acoustic mist ionization methodology is its data quality. This is due to (1) the difficulty in maintaining reproducibility in the mist generation (since regular acoustic dispensers operate by ejecting discrete, well-controlled nL droplets); and (2) the suppression effect exerted by the sample matrix. As a result, a CV of ∼30% has been reported for repeated analysis, which is considered somewhat to be high for ADME applications.
A more recent development in direct acoustic mass spectrometry has made significant progress in addressing these challenges. Developed by Sciex, their acoustic ejection mass spectrometer (AEMS) uses a simple yet elegant interface called open port interface (OPI) to capture the droplets and transport them with a stream of carrier solvent (typically methanol) into a conventional electrospray ionization source [[74], [75], [76]]. Fig. 2 shows the schematic of an AEMS system [76]. AEMS with OPI enjoys the similar sub-second/sample speed and direct analysis features to those of the AMI-MS approach. In addition, it has been demonstrated that AEMS can generate highly reproducible results from assay samples thanks to the low variability of acoustic ejection of nL-sized droplets and, more importantly, the mitigation of ionization suppression by the significant dilution (∼1000x) of the droplets by the carrier solvent. As a result, a typical CV of 3%–5% without the use of internal standards has been reported using AEMS for HTS and HT-ADME assay samples [74]. Obviously, the dilution effect does negatively affect the detection limit of the analytes. However, the low nM lower limit of quantitation (LLOQ) typically reported with AEMS should be sufficient to meet the requirements of most in vitro assays. Therefore, with its balance of high speed and high data quality, AEMS is poised to become the detection method of choice for label-free, biochemical or cell-based assays including those used in HT-ADME screening. A comparison of the several high-throughput MS-based readout methods for HT-ADME assays is presented in Table 2.
Fig. 2.
Schematic of the acoustic ejection mass spectrometer (AEMS) system. Reprinted with permission from Refs. [76], Copyright (2020) American Chemical Society.
Table 2.
Comparison of high-throughput MS analysis approaches. SPE: solid phase extraction; LDI: laser desorption ionization; AMI: acoustic mist ionization; AE: acoustic ejection.
| Parameters | LC-MS/MS | SPE-MS/MS | LDI-MS | AMI-MS | AE-MS |
|---|---|---|---|---|---|
| Speed per well | 60s | 10 s | 1 s | 1 s | 1 s |
| In situ sample clean up | Yes | Yes | No | No | Yes |
| Data variability | Low | Low | High | High | Low |
| Sample format | 96/384 | 96/384 | 96/384 | 384 | 384/1536 |
| Sample volume | >40 μL | >40 μL | <1 μL | <1 μL | <1 μL |
| Direct analysis | Yes | Yes | No | Yes | Yes |
3.3. High resolution mass spectrometry
In addition to the speed increase on the triple-quadrupole MS platform mentioned above, another emerging trend in HT-ADME bioanalysis is the use of high-resolution accurate mass (HRAM) capability of time-of-flight or Orbitrap mass spectrometers for sample analysis. Quantitative sample analysis of HT-ADME samples has been demonstrated with HRAM, typically by using the sample pooling approach to reduce sample numbers and take full advantage of the high resolving power of the mass spectrometer [77]. More importantly, a number of quantitative/qualitative workflows have been introduced to perform metabolic soft spot analysis concurrently with metabolic stability sample analysis [78,79].
4. Expansion of HT-ADME screening assay portfolio
4.1. Transporter assays
The assay portfolio of in vitro HT-ADME screening has continued to expand during the last decade and here we highlight some of the recently deployed assays in the field. Drug-drug-interactions and toxicity due to transporter involvement have been increasingly recognized as an important potential liability of drug candidates. As a result, inhibition assays for hepatobiliary and renal transporters (in addition to the existing intestinal transporters) have become an integral part of the drug-drug interaction (DDI) portfolio of many HT-ADME screening labs [10,11]. Some of the most commonly studied transporters in HT-ADME include hepatobiliary transporters such as organic anion-transporting polypeptide 1B1 (OATP1B1), organic anion-transporting polypeptide 1B3 (OATP1B3), sodium (Na+) taurocholate cotransporting polypeptide (NTCP), bile salt export pump (BSEP) [80], renal transporters such as organic anion transporter 1 (OAT1), organic anion transporter 3 (OAT3), organic cation transporter 1 (OCT1), organic cation transporter 2 (OCT2), multidrug and toxin extrusion protein 1 transporter (MATE1), multidrug and toxin extrusion protein 2K transporter (MATE2K) [10], and intestinal transporters such as P-glycoprotein (P-gp) and breast cancer resistance protein (BCRP) [81]. Most of the transporter screening assays are conducted in inhibition mode by assessing the potential of a drug candidate to act as a “perpetrator” by inhibiting the activity of a given transporter. If necessary, substrate assays can be used to assess whether a drug candidate is likely to become a “victim” of a transporter-mediated DDI [82].
4.2. HT-ADME assays for peptide drug candidates
Another growing area in HT-ADME screening is the characterization of peptide drug candidates. Since its inception, HT-ADME has been mostly used to assess the properties and liabilities of small molecule drug candidates. Recently, peptides have emerged as an attractive drug modality since they can combine target affinities similar to those of biologics with physicochemical properties closer to those of small molecules. Most peptide drugs are dosed by injection due to their poor proteolytic stability, low membrane permeability and low oral bioavailability [83]. A number of synthetic strategies [[84], [85], [86]] have been attempted to address these challenges for orally-dosed peptide drug candidates and, correspondingly, new or modified HT-ADME assays have been developed to facilitate the lead optimization in oral peptide drug discovery. For example, permeability assays such as colon adenocarcinoma cell line (Caco-2) or parallel artificial membrane permeability assay (PAMPA) have both been used to assess the permeability of peptides [84,87]. However, due to the non-specific binding typically exhibited by peptides and the generally very low permeability values, they tend to generate null results in these assays. Therefore, assay conditions have been modified to address these challenges. Also, additional assays such as chromatography-based experimental polar surface area (EPSA) have been developed specifically to assess the permeability of peptides [88].
4.3. High-throughput soft spot identification assays
The in vitro metabolic soft spot assay is another recent addition to the HT-ADME assay portfolio [89]. Unlike most HT-ADME assays with numbers as end points (IC50, permeability values, percent bound, etc.), the metabolic soft spot assay provides structural information about the sites of metabolism (SOM), or “soft spots” of discovery compounds. Historically a very low throughput assay conducted only for a handful of lead compounds, metabolic soft spot assays have recently become quite common in HT-ADME. This is due to technological developments in two areas: first, the availability of high-performance, high-resolution mass spectrometers with generic data acquisition methods [90,91]; and, second, the development of software tools to perform automated structural elucidation in batch mode [92,93]. Equipped with the SOM information from the soft spot assay, discovery projects can now address metabolic instability synthetically for both small molecules and peptides in a more targeted way than before.
5. Future perspective
Thanks to the evolving sciences and enabling technologies, we anticipate more exciting developments in the field of HT-ADME in next decade. From an assay portfolio standpoint, emerging areas of ADME sciences will inevitably find their way into HT-ADME screening. Examples of these include new, more physiologically relevant in vitro microphysiological systems (MPS) such as 3D tissue cultures and organ(s)-on-a-chip [[94], [95], [96], [97], [98]], for better in vitro in vivo translation (IVIVT). Another trend in ADME is the use of endogenous probes (essentially biomarkers) for transporter DDI studies in vivo, which has the potential advantages of reducing pill burden and obtaining transporter DDI information from a regular phase I study [[99], [100], [101], [102], [103], [104]]. Once the endogenous probes are validated, it is foreseeable that the corresponding in vitro HT assays can be implemented in a screening mode as well. Yet another example is HT-ADME screening of new drug modalities. In addition to small molecules and peptides, the field is poised to enter early ADME screening of new modalities including protein degraders [[105], [106], [107]], antisense oligonucleotides (ASO’s) [[108], [109], [110]], antibody drug conjugates (ADC’s) [[111], [112], [113], [114]] and biologics [[115], [116], [117]]. Although the ADME science of these modalities is still currently developing, we expect more and more HT-ADME format assays will become online to support discovery efforts along with the evolving science.
With the long history of HT-ADME operation in many companies and the resulting wealth of ADME data that can be “mined”, developing in silico models to predict ADME properties has long been recognized as the logical next step for HT-ADME screening [118,119]. While many ADME predictive models reported in the literature use a training set of only several hundred compounds, a large pharmaceutical company’s HT-ADME dataset could contain assay results from several hundred thousand compounds. These datasets can serve as the ideal training sets for model development due to its large size, and also the fact that they are a much better representation of the chemical space occupied by the compound collection of the particular company. Computational chemistry approaches aimed at developing quantitative structure-activity relationship (QSAR) models have long been applied to ADME properties [120,121]. More recently, various machine learning (ML) methods have been applied to develop models for clearance, permeability and DDI potentials [[122], [123], [124], [125], [126]]. With the recent rapid development in machine learning methodologies, and the large size of the HT-ADME datasets available to use as training sets, it is expected that even better predictive ADME models can be developed in the future to guide efforts such as hit triaging from lead discovery screens and in the design-make-test cycles of lead optimization in drug discovery [127].
Conflicts of interest
The author declares that there are no conflicts of interest.
Acknowledgments
The author would like to thank all colleagues in Lead Profiling (LP) and Separation and Analysis Technology Team (SATT) of Bristol-Myers Squibb Co..
Footnotes
Peer review under responsibility of Xi'an Jiaotong University.
Supplementary data to this article can be found online at https://doi.org/10.1016/j.jpha.2020.05.004.
Appendix A. Supplementary data
The following is the Supplementary data to this article:
References
- 1.Li A.P. Screening for human ADME/Tox drug properties in drug discovery. Drug Discov. Today. 2001;6:357–366. doi: 10.1016/s1359-6446(01)01712-3. [DOI] [PubMed] [Google Scholar]
- 2.Kerns E.H. Editorial: high throughput in vitro ADME/tox profiling for drug discovery. Curr. Drug Metabol. 2008;9:845–846. [Google Scholar]
- 3.Carlson T.J., Fisher M.B. Recent advances in high throughput screening for ADME properties. Comb. Chem. High Throughput Screen. 2008;11:258–264. doi: 10.2174/138620708783877717. [DOI] [PubMed] [Google Scholar]
- 4.Xu R., Manuel M., Cramlett J. A high throughput metabolic stability screening workflow with automated assessment of data quality in pharmaceutical industry. J. Chromatogr. A. 2010;1217:1616–1625. doi: 10.1016/j.chroma.2010.01.009. [DOI] [PubMed] [Google Scholar]
- 5.Kieltyka K., Zhang J., Li S. A high-throughput bioanalytical platform using automated infusion for tandem mass spectrometric method optimization and its application in a metabolic stability screen. Rapid Commun. Mass Spectrom. 2009;23:1579–1591. doi: 10.1002/rcm.4037. [DOI] [PubMed] [Google Scholar]
- 6.Cai X., Walker A., Cheng C. Approach to improve compound recovery in a high-throughput Caco-2 permeability assay supported by liquid chromatography–tandem mass spectrometry. J. Pharm. Sci. 2012;101:2755–2762. doi: 10.1002/jps.23194. [DOI] [PubMed] [Google Scholar]
- 7.Cai X., Madari S., Walker A. Addition of optimized bovine serum albumin level in a high-throughput Caco-2 assay enabled accurate permeability assessment for lipophilic compounds. SLAS Discov. 2019;24:738–744. doi: 10.1177/2472555219848483. [DOI] [PubMed] [Google Scholar]
- 8.Skolnik S., Lin X., Wang J. Towards prediction of in vivo intestinal absorption using a 96-well Caco-2 assay. J. Pharm. Sci. 2010;99:3246–3265. doi: 10.1002/jps.22080. [DOI] [PubMed] [Google Scholar]
- 9.Wu X., Wang J., Tan L. In vitro ADME profiling using high-throughput rapidfire mass spectrometry: cytochrome P450 inhibition and metabolic stability assays. J. Biomol. Screen. 2012;17:761–772. doi: 10.1177/1087057112441013. [DOI] [PubMed] [Google Scholar]
- 10.Vath M., Gallagher L., Shou W. Development of an LC–MS/MS method for high throughput quantification of metformin uptake in transporter inhibition assays. J. Chromatogr. B. 2014;967:211–218. doi: 10.1016/j.jchromb.2014.07.024. [DOI] [PubMed] [Google Scholar]
- 11.Wagner A.D., Elkin L., Mosure K. Development of a high-throughput mass spectrometry based analytical method to support an in vitro OATP1B1 inhibition screening assay. Rapid Commun. Mass Spectrom. 2016;30:1787–1796. doi: 10.1002/rcm.7655. [DOI] [PubMed] [Google Scholar]
- 12.Alsenz J., Kansy M. High throughput solubility measurement in drug discovery and development. Adv. Drug Deliv. Rev. 2007;59:546–567. doi: 10.1016/j.addr.2007.05.007. [DOI] [PubMed] [Google Scholar]
- 13.Zhang J., Shou W.Z., Vath M. An integrated bioanalytical platform for supporting high-throughput serum protein binding screening. Rapid Commun. Mass Spectrom. 2010;24:3593–3601. doi: 10.1002/rcm.4817. [DOI] [PubMed] [Google Scholar]
- 14.Di Veroli G.Y., Davies M.R., Zhang H. High-throughput screening of drug-binding dynamics to HERG improves early drug safety assessment. Am. J. Physiol. Heart Circ. Physiol. 2012;304:H104–H117. doi: 10.1152/ajpheart.00511.2012. [DOI] [PubMed] [Google Scholar]
- 15.Su X., Young E.W.K., Underkofler H.A.S. Microfluidic cell culture and its application in high-throughput drug screening: cardiotoxicity assay for hERG channels. J. Biomol. Screen. 2010;16:101–111. doi: 10.1177/1087057110386218. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Soikkeli A., Sempio C., Kaukonen A.M. Feasibility evaluation of 3 automated cellular drug screening assays on a robotic workstation. J. Biomol. Screen. 2009;15:30–41. doi: 10.1177/1087057109352236. [DOI] [PubMed] [Google Scholar]
- 17.Shou W.Z., Zhang J. Recent development in high-throughput bioanalytical support for in vitro ADMET profiling. Expet Opin. Drug Metabol. Toxicol. 2010;6:321–336. doi: 10.1517/17425250903547829. [DOI] [PubMed] [Google Scholar]
- 18.Miller V.P. SPE–MS analysis of absorption, distribution, metabolism and excretion assays: a tool to increase throughput and steamline workflow. Bioanalysis. 2012;4:1111–1121. doi: 10.4155/bio.12.86. [DOI] [PubMed] [Google Scholar]
- 19.Shou W.Z., Zhang J. Recent development in software and automation tools for high-throughput discovery bioanalysis. Bioanalysis. 2012;4:1097–1109. doi: 10.4155/bio.12.51. [DOI] [PubMed] [Google Scholar]
- 20.Larson B., Banks P., Sherman H. Automation of cell-based drug absorption assays in 96-well format using permeable support systems. J. Lab. Autom. 2012;17:222–232. doi: 10.1177/2211068211428190. [DOI] [PubMed] [Google Scholar]
- 21.Janiszewski J., Levitt N. Enabling software for high-throughput bioanalysis. In: Shou W.Z., Weng N., editors. Eliminating Bottlenecks for Efficient Bioanalysis: Practices and Applications in Drug Discovery and Development. Future Science Ltd.; London: 2014. pp. 34–50. [Google Scholar]
- 22.Heinle L., Peterkin V., de Morais S.M. A high throughput, 384-well, semi-automated, hepatocyte intrinsic clearance assay for screening new molecular entities in drug discovery. Comb. Chem. High Throughput Screen. 2015;18:442–452. doi: 10.2174/1386207318666150401101737. [DOI] [PubMed] [Google Scholar]
- 23.Waring M.J., Arrowsmith J., Leach A.R. An analysis of the attrition of drug candidates from four major pharmaceutical companies. Nat. Rev. Drug Discov. 2015;14:475–486. doi: 10.1038/nrd4609. [DOI] [PubMed] [Google Scholar]
- 24.Wang J., Urban L., Bojanic D. Maximising use of in vitro ADMET tools to predict in vivo bioavailability and safety. Expet Opin. Drug Metabol. Toxicol. 2007;3:641–665. doi: 10.1517/17425255.3.5.641. [DOI] [PubMed] [Google Scholar]
- 25.Wan H., Holmén A.G. High throughput screening of physicochemical properties and in vitro ADME profiling in drug discovery. Comb. Chem. High Throughput Screen. 2009;12:315–329. doi: 10.2174/138620709787581701. [DOI] [PubMed] [Google Scholar]
- 26.Wang J., Skolnik S. Recent advances in physicochemical and ADMET profiling in drug discovery. Chem. Biodivers. 2009;6:1887–1899. doi: 10.1002/cbdv.200900117. [DOI] [PubMed] [Google Scholar]
- 27.Zhang J., Shou W.Z. Mass spectrometry for quantitative in vitro ADME assays. In: Korfmacher W.A., editor. Mass Spectrometry for Drug Discovery and Drug Development. John Wiley & Sons, Inc.; New York: 2013. pp. 97–113. [Google Scholar]
- 28.Fitzgerald M.A.M. Strategies for high-throughput sample analysis. In: Shou W.Z., Weng N., editors. Eliminating Bottlenecks for Efficient Bioanalysis: Practices and Applications in Drug Discovery and Development. Future Science Ltd.; London: 2014. pp. 18–33. [Google Scholar]
- 29.Kerns E.H., Di L. Automation in pharmaceutical profiling. J. Lab. Autom. 2005;10:114–123. [Google Scholar]
- 30.Kerns E.H., Di L. Utility of mass spectrometry for pharmaceutical profiling applications. Curr. Drug Metabol. 2006;7:457–466. doi: 10.2174/138920006777697981. [DOI] [PubMed] [Google Scholar]
- 31.Kassel D.B. Applications of high-throughput ADME in drug discovery. Curr. Opin. Chem. Biol. 2004;8:339–345. doi: 10.1016/j.cbpa.2004.04.015. [DOI] [PubMed] [Google Scholar]
- 32.Jenkins K.M., Angeles R., Quintos M.T. Automated high throughput ADME assays for metabolic stability and cytochrome P450 inhibition profiling of combinatorial libraries. J. Pharmaceut. Biomed. Anal. 2004;34:989–1004. doi: 10.1016/j.jpba.2003.08.001. [DOI] [PubMed] [Google Scholar]
- 33.Janiszewski J.S., Rogers K.J., Whalen K.M. A high-capacity LC/MS system for the bioanalysis of samples generated from plate-based metabolic screening. Anal. Chem. 2001;73:1495–1501. doi: 10.1021/ac0013251. [DOI] [PubMed] [Google Scholar]
- 34.Xu R., Nemes C., Jenkins K.M. Application of parallel liquid chromatography/mass spectrometry for high throughput microsomal stability screening of compound libraries. J. Am. Soc. Mass Spectrom. 2002;13:155–165. doi: 10.1016/S1044-0305(01)00342-7. [DOI] [PubMed] [Google Scholar]
- 35.Briem S., Pettersson B., Skoglund E. Description and validation of a four-channel staggered LC-MS/MS systems for high-throughput in vitro screens. Anal. Chem. 2005;77:1905–1910. doi: 10.1021/ac049077m. [DOI] [PubMed] [Google Scholar]
- 36.Kerns E.H., Kleintop T., Little D. Integrated high capacity solid phase extraction-MS/MS system for pharmaceutical profiling in drug discovery. J. Pharmaceut. Biomed. Anal. 2004;34:1–9. doi: 10.1016/j.japna.2003.03.001. [DOI] [PubMed] [Google Scholar]
- 37.Youdim K.A., Lyons R., Payne L. An automated, high-throughput, 384 well Cytochrome P450 cocktail IC50 assay using a rapid resolution LC–MS/MS end-point. J. Pharmaceut. Biomed. Anal. 2008;48:92–99. doi: 10.1016/j.jpba.2008.05.011. [DOI] [PubMed] [Google Scholar]
- 38.Dutton G. Life sciences labs need cobots, not robots. Genet. Eng. Biotechnol. News. 2018;38:8–9. [Google Scholar]
- 39.Mukadam S., Tay S., Tran D. Evaluation of time-dependent Cytochrome P450 inhibition in a high-throughput, automated assay: introducing a novel area under the curve shift approach. Drug Metabol. Lett. 2012;6:43–53. doi: 10.2174/187231212800229309. [DOI] [PubMed] [Google Scholar]
- 40.Berna M.J., Ackermann B.L., Murphy A.T. High-throughput chromatographic approaches to liquid chromatographic/tandem mass spectrometric bioanalysis to support drug discovery and development. Anal. Chim. Acta. 2004;509:1–9. [Google Scholar]
- 41.Kieltyka K., Zhang J., Li S. A high-throughput bioanalytical platform using automated infusion for tandem mass spectrometric method optimization and its application in a metabolic stability screen. Rapid Commun. Mass Spectrom. 2009;23:1579–1591. doi: 10.1002/rcm.4037. [DOI] [PubMed] [Google Scholar]
- 42.Zhang J., Vath M., Ferraro C. A high-speed liquid chromatography/tandem mass spectrometry platform using multiplexed multiple-injection chromatography controlled by single software and its application in discovery ADME screening. Rapid Commun. Mass Spectrom. 2013;27:731–737. doi: 10.1002/rcm.6514. [DOI] [PubMed] [Google Scholar]
- 43.Luippold A.H., Arnhold T., Jörg W. Application of a rapid and integrated analysis system (RIAS) as a high-throughput processing tool for in vitro ADME samples by liquid chromatography/tandem mass spectrometry. J. Biomol. Screen. 2011;16:370–377. doi: 10.1177/1087057110397358. [DOI] [PubMed] [Google Scholar]
- 44.Luippold A.H., Arnhold T., Jörg W. An integrated platform for fully automated high-throughput LC–MS/MS analysis of in vitro metabolic stability assay samples. Int. J. Mass Spectrom. 2010;296:1–9. [Google Scholar]
- 45.Smalley J., Xin B., Olah T.V. Increasing high-throughput Discovery bioanalysis using automated selected reaction monitoring compound optimization, ultra-high-pressure liquid chromatography, and single-step sample preparation workflows. Rapid Commun. Mass Spectrom. 2009;23:3457–3464. doi: 10.1002/rcm.4264. [DOI] [PubMed] [Google Scholar]
- 46.Zhang J., Shou W.Z., Vath M. Integrated bioanalytical platform for supporting a high throughput serum protein binding screen. Rapid Commun. Mass Spectrom. 2010;24:3593–3601. doi: 10.1002/rcm.4817. [DOI] [PubMed] [Google Scholar]
- 47.Murphy K., Bennett P.K., Duczak N. High-throughput quantitation of large molecules using multiplexed chromatography and high-resolution/accurate mass LC–MS. Bioanalysis. 2012;4:1013–1024. doi: 10.4155/bio.12.71. [DOI] [PubMed] [Google Scholar]
- 48.Whalen K.M., Rogers K.J., Cole M.J. AutoScan: an automated workstation for rapid determination of mass and tandem mass spectrometry conditions for quantitative bioanalytical mass spectrometry. Rapid Commun. Mass Spectrom. 2000;14:2074–2079. doi: 10.1002/1097-0231(20001115)14:21<2074::AID-RCM131>3.0.CO;2-A. [DOI] [PubMed] [Google Scholar]
- 49.Whalen K., Gobey J., Janiszewski J. A centralized approach to tandem mass spectrometry method development for high-throughput ADME screening. Rapid Commun. Mass Spectrom. 2006;20:1497–1503. doi: 10.1002/rcm.2469. [DOI] [PubMed] [Google Scholar]
- 50.Amaral A., Saran C., Amin J. A comparison of LC-MS/MS and a fully integrated autosampler/solid-phase extraction system for the analysis of protein binding samples. J. Biomol. Screen. 2016;21:620–625. doi: 10.1177/1087057116630706. [DOI] [PubMed] [Google Scholar]
- 51.Janiszewski J., Schneider R., Kapinos B. Development of a high-speed, multiplexed sample-delivery instrument for LC–MS/MS bioanalysis. Bioanalysis. 2012;4:1039–1056. doi: 10.4155/bio.12.87. [DOI] [PubMed] [Google Scholar]
- 52.Kapinos B., Liu J., Piotrowski M. Development of a high-performance, enterprise-level, multimode LC–MS/MS autosampler for drug discovery. Bioanalysis. 2017;9:1643–1654. doi: 10.4155/bio-2017-0149. [DOI] [PubMed] [Google Scholar]
- 53.Ballard P., Brassil P., Bui K.H. The right compound in the right assay at the right time: an integrated discovery DMPK strategy. Drug Metab. Rev. 2012;44:224–252. doi: 10.3109/03602532.2012.691099. [DOI] [PubMed] [Google Scholar]
- 54.Lu X. Development of an Excel-based laboratory information management system for improving workflow efficiencies in early ADME screening. Bioanalysis. 2016;8:99–110. doi: 10.4155/bio.15.232. [DOI] [PubMed] [Google Scholar]
- 55.Wang H., Zrada M., Anderson K. Understanding and reducing the experimental variability of in vitro plasma protein binding measurements. J. Pharm. Sci. 2014;103:3302–3309. doi: 10.1002/jps.24119. [DOI] [PubMed] [Google Scholar]
- 56.Clark G.T. HT-ADME in a contract research organization laboratory: can you ensure bioanalytical quality in a highly automated environment? Bioanalysis. 2015;7:403–406. doi: 10.4155/bio.14.313. [DOI] [PubMed] [Google Scholar]
- 57.Padilha E.C., Wang J., Kerns E. Application of in vitro drug metabolism studies in chemical structure optimization for the treatment of fibrodysplasia ossificans progressiva (FOP) Front. Pharmacol. 2019;10:234. doi: 10.3389/fphar.2019.00234. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 58.Gardell S.J., Roth G.P., Kelly D.P. Cardiovascular drug discovery in the academic setting: building infrastructure, harnessing strengths, and seeking synergies. J. Cardiovasc. Transl. Res. 2010;3:431–437. doi: 10.1007/s12265-010-9204-8. [DOI] [PubMed] [Google Scholar]
- 59.Integrated nanoliter dispensing aids drug discovery. 2014. https://www.tecan.com/hubfs/Tecan_Journal/201401/20_21_Integrated_nanoliter_dispensing_aids_drug_discovery_012014.pdf
- 60.Ellson R., Mutz M., Browning B. Transfer of low nanoliter volumes between microplates using focused acoustics—automation considerations. J. Lab. Autom. 2003;8:29–34. [Google Scholar]
- 61.Grant R.J., Roberts K., Pointon C. Achieving accurate compound concentration in cell-based screening: validation of acoustic droplet ejection technology. J. Biomol. Screen. 2009;14:452–459. doi: 10.1177/1087057109336588. [DOI] [PubMed] [Google Scholar]
- 62.Griffith D., Northwood R., Owen P. Implementation and development of an automated, ultra-high-capacity, acoustic, flexible dispensing platform for assay-ready plate delivery. J. Lab. Autom. 2012;17:348–358. doi: 10.1177/2211068212457159. [DOI] [PubMed] [Google Scholar]
- 63.Luippold A.H., Arnhold T., Joerg W. Proceedings of the 57th ASMS Conference on Mass Spectrometry and Allied Topics, Philadelphia, United States. 2009. A novel and integrated platform for fully automated high-throughput LC/MS/MS analysis of in vitro ADME samples. [Google Scholar]
- 64.Winter M., Ries R., Kleiner C. Automated MALDI target preparation concept: providing ultra-high-throughput mass spectrometry–based screening for drug discovery. SLAS Technol. 2018;24:209–221. doi: 10.1177/2472630318791981. [DOI] [PubMed] [Google Scholar]
- 65.Dion-Fortier A., Gravel A., Guérette C. Signal enhancement in laser diode thermal desorption-triple quadrupole mass spectrometry analysis using microwell surface coatings. J. Mass Spectrom. 2019;54:167–177. doi: 10.1002/jms.4328. [DOI] [PubMed] [Google Scholar]
- 66.Yu S., Crawford E., Tice J. Bioanalysis without sample cleanup or chromatography: the evaluation and initial implementation of direct analysis in real time ionization mass spectrometry for the quantification of drugs in biological matrixes. Anal. Chem. 2009;81:193–202. doi: 10.1021/ac801734t. [DOI] [PubMed] [Google Scholar]
- 67.Kasperkiewicz A., Gómez-Ríos G.A., Hein D. Breaching the 10 second barrier of total analysis time for complex matrices via automated coated blade spray. Anal. Chem. 2019;91:13039–13046. doi: 10.1021/acs.analchem.9b03225. [DOI] [PubMed] [Google Scholar]
- 68.Wei Z., Xie Z., Kuvelkar R. High-throughput bioassays using “dip-and-go” multiplexed electrospray mass spectrometry. Angew. Chem. 2019;58:17594–17598. doi: 10.1002/anie.201909047. [DOI] [PubMed] [Google Scholar]
- 69.Haslam C., Hellicar J., Dunn A. The evolution of MALDI-TOF mass spectrometry toward ultra-high-throughput screening: 1536-well format and beyond. J. Biomol. Screen. 2015;21:176–186. doi: 10.1177/1087057115608605. [DOI] [PubMed] [Google Scholar]
- 70.Haarhoff Z., Wagner A., Picard P. Coupling laser diode thermal desorption with acoustic sample deposition to improve throughput of mass spectrometry–based screening. J. Biomol. Screen. 2015;21:165–175. doi: 10.1177/1087057115607184. [DOI] [PubMed] [Google Scholar]
- 71.Chandler J., Haslam C., Hardy N. A systematic investigation of the best buffers for use in screening by maldi–mass spectrometry. SLAS Discov. 2016;22:1262–1269. doi: 10.1177/1087057116681726. [DOI] [PubMed] [Google Scholar]
- 72.Sinclair I., Stearns R., Pringle S. Novel acoustic loading of a mass spectrometer: toward next-generation high-throughput ms screening. J. Lab. Autom. 2015;21:19–26. doi: 10.1177/2211068215619124. [DOI] [PubMed] [Google Scholar]
- 73.Sinclair I., Bachman M., Addison D. Acoustic mist ionization platform for direct and contactless ultrahigh-throughput mass spectrometry analysis of liquid samples. Anal. Chem. 2019;91:3790–3794. doi: 10.1021/acs.analchem.9b00142. [DOI] [PubMed] [Google Scholar]
- 74.Zhang H., Liu C., Hua W. Acoustic ejection mass spectrometry for high-throughput analysis. bioRxiv. 2020:2020. doi: 10.1021/acs.analchem.1c01137. 01.28.923938. [DOI] [PubMed] [Google Scholar]
- 75.Zhang H. Acoustic dispensing-mass spectrometry: the next high throughput bioanalytical platform for early drug discovery. Bioanalysis. 2017;9:1619–1621. doi: 10.4155/bio-2017-4980. [DOI] [PubMed] [Google Scholar]
- 76.DiRico K.J., Hua W., Liu C. Ultra-high-throughput acoustic droplet ejection-open port interface-mass spectrometry for parallel medicinal chemistry. ACS Med. Chem. Lett. 2020 doi: 10.1021/acsmedchemlett.0c00066. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 77.Zhang J., Maloney J., Drexler D.M. Cassette incubation followed by bioanalysis using high-resolution MS for in vitro ADME screening assays. Bioanalysis. 2012;4:581–593. doi: 10.4155/bio.12.2. [DOI] [PubMed] [Google Scholar]
- 78.Backfisch G., Reder-Hilz B., Hoeckels-Messemer J. High-throughput quantitative and qualitative analysis of microsomal incubations by cocktail analysis with an ultraperformance liquid chromatography-quadrupole time-of-flight mass spectrometer system. Bioanalysis. 2014;7:671–683. doi: 10.4155/bio.14.314. [DOI] [PubMed] [Google Scholar]
- 79.Grubb M.F., Humphreys W.G., Josephs J.L. A semi-automated method for the integrated evaluation of half-life and metabolic soft spots of discovery compounds. Bioanalysis. 2012;4:1747–1761. doi: 10.4155/bio.12.134. [DOI] [PubMed] [Google Scholar]
- 80.Tang H., Shen D.R., Han Y.-H. Development of novel, 384-well high-throughput assay panels for human drug transporters: drug interaction and safety assessment in support of discovery research. J. Biomol. Screen. 2013;18:1072–1083. doi: 10.1177/1087057113494807. [DOI] [PubMed] [Google Scholar]
- 81.Wagner A.D., Kolb J.M., Özbal C.C. Ultrafast mass spectrometry based bioanalytical method for digoxin supporting an in vitro P-glycoprotein (P-gp) inhibition screen. Rapid Commun. Mass Spectrom. 2011;25:1231–1240. doi: 10.1002/rcm.4984. [DOI] [PubMed] [Google Scholar]
- 82.Brouwer K.L.R., Keppler D., Hoffmaster K.A. In vitro methods to support transporter evaluation in drug discovery and development. Clin. Pharmacol. Ther. 2013;94:95–112. doi: 10.1038/clpt.2013.81. [DOI] [PubMed] [Google Scholar]
- 83.Di L. Strategic approaches to optimizing peptide ADME properties. AAPS J. 2015;17:134–143. doi: 10.1208/s12248-014-9687-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 84.Rand A.C., Leung S.S.F., Eng H. Optimizing PK properties of cyclic peptides: the effect of side chain substitutions on permeability and clearance. Med. Chem. Commun. 2012;3:1282–1289. doi: 10.1039/C2MD20203D. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 85.Werle M., Bernkop-Schnürch A. Strategies to improve plasma half life time of peptide and protein drugs. Amino Acids. 2006;30:351–367. doi: 10.1007/s00726-005-0289-3. [DOI] [PubMed] [Google Scholar]
- 86.Chatterjee J., Laufer B., Kessler H. Synthesis of N-methylated cyclic peptides. Nat. Protoc. 2012;7:432–444. doi: 10.1038/nprot.2011.450. [DOI] [PubMed] [Google Scholar]
- 87.Ano R., Kimura Y., Shima M. Relationships between structure and high-throughput screening permeability of peptide derivatives and related compounds with artificial membranes: application to prediction of Caco-2 cell permeability. Bioorg. Med. Chem. 2004;12:257–264. doi: 10.1016/j.bmc.2003.10.002. [DOI] [PubMed] [Google Scholar]
- 88.Goetz G.H., Philippe L., Shapiro M.J. EPSA: a novel supercritical fluid chromatography technique enabling the design of permeable cyclic peptides. ACS Med. Chem. Lett. 2014;5:1167–1172. doi: 10.1021/ml500239m. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 89.Paiva A.A., Klakouski C., Li S. Development, optimization and implementation of a centralized metabolic soft spot assay. Bioanalysis. 2017;9:541–552. doi: 10.4155/bio-2016-0299. [DOI] [PubMed] [Google Scholar]
- 90.Mortishire-Smith R.J., Zhang H., Bateman K.P. High-resolution mass spectrometry and drug metabolite identification. In: Lee M.S., Zhu M., editors. Mass Spectrometry in Drug Metabolism and Disposition. John Wiley & Sons, Inc.; New York: 2011. pp. 407–448. [Google Scholar]
- 91.Zhu X., Chen Y., Subramanian R. Comparison of information-dependent acquisition, SWATH, and MSA techniques in metabolite identification study employing ultrahigh-performance liquid chromatography–quadrupole time-of-flight mass spectrometry. Anal. Chem. 2014;86:1202–1209. doi: 10.1021/ac403385y. [DOI] [PubMed] [Google Scholar]
- 92.Paiva A., Shou W.Z. Recent developments in software tools for high-throughput in vitro ADME support with high-resolution MS. Bioanalysis. 2016;8:1723–1733. doi: 10.4155/bio-2016-0074. [DOI] [PubMed] [Google Scholar]
- 93.Ahlqvist M., Leandersson C., Hayes M.A. Software-aided structural elucidation in drug discovery. Rapid Commun. Mass Spectrom. 2015;29:2083–2089. doi: 10.1002/rcm.7364. [DOI] [PubMed] [Google Scholar]
- 94.Fowler S., Chen W.L.K., Duignan D.B. Microphysiological systems for ADME-related applications: current status and recommendations for system development and characterization. Lab Chip. 2020;20:446–467. doi: 10.1039/c9lc00857h. [DOI] [PubMed] [Google Scholar]
- 95.Fabre K., Berridge B., Proctor W.R. Introduction to a manuscript series on the characterization and use of microphysiological systems (MPS) in pharmaceutical safety and ADME applications. Lab Chip. 2020;20:1049–1057. doi: 10.1039/c9lc01168d. [DOI] [PubMed] [Google Scholar]
- 96.Docci L., Parrott N., Krähenbühl S. Application of new cellular and microphysiological systems to drug metabolism optimization and their positioning respective to in silico tools. SLAS Discov. 2019;24:523–536. doi: 10.1177/2472555219831407. [DOI] [PubMed] [Google Scholar]
- 97.An F., Qu Y., Luo Y. A laminated microfluidic device for comprehensive preclinical testing in the drug ADME process. Sci. Rep. 2016;6:25022. doi: 10.1038/srep25022. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 98.Ishida S. Organs-on-a-chip: current applications and consideration points for in vitro ADME-Tox studies. Drug Metabol. Pharmacokinet. 2018;33:49–54. doi: 10.1016/j.dmpk.2018.01.003. [DOI] [PubMed] [Google Scholar]
- 99.Rodrigues A.D., Taskar K.S., Kusuhara H. Endogenous probes for drug transporters: balancing vision with reality. Clin. Pharmacol. Ther. 2018;103:434–448. doi: 10.1002/cpt.749. [DOI] [PubMed] [Google Scholar]
- 100.Chu X., Liao M., Shen H. Clinical probes and endogenous biomarkers as substrates for transporter drug-drug interaction evaluation: perspectives from the international transporter consortium. Clin. Pharmacol. Ther. 2018;104:836–864. doi: 10.1002/cpt.1216. [DOI] [PubMed] [Google Scholar]
- 101.King-Ahmad A., Clemens S., Ramanathan R. A fully automated and validated human plasma LC–MS/MS assay for endogenous OATP biomarkers coproporphyrin-I and coproporphyrin-III. Bioanalysis. 2018;10:691–701. doi: 10.4155/bio-2017-0270. [DOI] [PubMed] [Google Scholar]
- 102.Luo L., Kay J., Zhang J. LC–MS/MS assay for N1-methylnicotinamide in humans, an endogenous probe for renal transporters. Bioanalysis. 2018;10:673–689. doi: 10.4155/bio-2017-0272. [DOI] [PubMed] [Google Scholar]
- 103.Barnett S., Ogungbenro K., Ménochet K. Comprehensive evaluation of the utility of 20 endogenous molecules as biomarkers of OATP1B inhibition compared with rosuvastatin and coproporphyrin I. J. Pharmacol. Exp. Therapeut. 2019;368:125–135. doi: 10.1124/jpet.118.253062. [DOI] [PubMed] [Google Scholar]
- 104.Rodrigues D., Rowland A. From endogenous compounds as biomarkers to plasma-derived nanovesicles as liquid biopsy; has the golden age of translational pharmacokinetics-absorption, distribution, metabolism, excretion-drug–drug interaction science finally arrived? Clin. Pharmacol. Ther. 2019;105:1407–1420. doi: 10.1002/cpt.1328. [DOI] [PubMed] [Google Scholar]
- 105.Toure M., Crews C.M. Small-molecule PROTACS: new approaches to protein degradation. Angew. Chem. 2016;55:1966–1973. doi: 10.1002/anie.201507978. [DOI] [PubMed] [Google Scholar]
- 106.Edmondson S.D., Yang B., Fallan C. Proteolysis targeting chimeras (PROTACs) in ‘beyond rule-of-five’ chemical space: recent progress and future challenges. Bioorg. Med. Chem. Lett. 2019;29:1555–1564. doi: 10.1016/j.bmcl.2019.04.030. [DOI] [PubMed] [Google Scholar]
- 107.Cantrill C., Chaturvedi P., Rynn C. Fundamental aspects of DMPK optimization of targeted protein degraders. Drug Discov. Today. 2020 doi: 10.1016/j.drudis.2020.03.012. [DOI] [PubMed] [Google Scholar]
- 108.Geary R.S. Antisense oligonucleotide pharmacokinetics and metabolism. Expet Opin. Drug Metabol. Toxicol. 2009;5:381–391. doi: 10.1517/17425250902877680. [DOI] [PubMed] [Google Scholar]
- 109.Kazmi F., Yerino P., McCoy C. An assessment of the in vitro inhibition of Cytochrome P450 enzymes, UDP-glucuronosyltransferases, and transporters by phosphodiester- or phosphorothioate-linked oligonucleotides. Drug Metab. Dispos. 2018;46:1066–1074. doi: 10.1124/dmd.118.081729. [DOI] [PubMed] [Google Scholar]
- 110.Ramsden D., Wu J.-T., Zerler B. In vitro drug-drug interaction evaluation of GalNAc conjugated sirnas against CYP450 enzymes and transporters. Drug Metab. Dispos. 2019;47:1183–1194. doi: 10.1124/dmd.119.087098. [DOI] [PubMed] [Google Scholar]
- 111.Kraynov E., Kamath A.V., Walles M. Current approaches for absorption, distribution, metabolism, and excretion characterization of antibody-drug conjugates: an industry white paper. Drug Metab. Dispos. 2016;44:617–623. doi: 10.1124/dmd.115.068049. [DOI] [PubMed] [Google Scholar]
- 112.Tumey L.N., Han S. ADME considerations for the development of biopharmaceutical conjugates using cleavable linkers. Curr. Top. Med. Chem. 2017;17:3444–3462. doi: 10.2174/1568026618666180118154017. [DOI] [PubMed] [Google Scholar]
- 113.Durbin K.R., Nottoli M.S., Catron N.D. High-Throughput, multispecies, parallelized plasma stability assay for the determination and characterization of antibody–drug conjugate aggregation and drug release. ACS Omega. 2017;2:4207–4215. doi: 10.1021/acsomega.7b00452. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 114.Fourie-O’Donohue A., Chu P.Y., dela Cruz Chuh J. Improved translation of stability for conjugated antibodies using an in vitro whole blood assay. mAbs. 2020;12:1715705. doi: 10.1080/19420862.2020.1715705. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 115.Prueksaritanont T., Tang C. ADME of biologics—what have we learned from small molecules? AAPS J. 2012;14:410–419. doi: 10.1208/s12248-012-9353-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 116.Datta-Mannan A. Mechanisms influencing the pharmacokinetics and disposition of monoclonal antibodies and peptides. Drug Metab. Dispos. 2019;47:1100–1110. doi: 10.1124/dmd.119.086488. [DOI] [PubMed] [Google Scholar]
- 117.Tibbitts J., Canter D., Graff R. Key factors influencing ADME properties of therapeutic proteins: a need for ADME characterization in drug discovery and development. mAbs. 2016;8:229–245. doi: 10.1080/19420862.2015.1115937. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 118.Hop C.E.C.A., Cole M.J., Davidson R.E. High throughput ADME screening: practical considerations, impact on the portfolio and enabler of in silico adme models. Curr. Drug Metabol. 2008;9:847–853. doi: 10.2174/138920008786485092. [DOI] [PubMed] [Google Scholar]
- 119.Ferreira L.L.G., Andricopulo A.D. ADMET modeling approaches in drug discovery. Drug Discov. Today. 2019;24:1157–1165. doi: 10.1016/j.drudis.2019.03.015. [DOI] [PubMed] [Google Scholar]
- 120.Arkadiusz Z.D., Tomasz A., Jorge G. Computational methods in developing quantitative structure-activity relationships (QSAR): a Review. Comb. Chem. High Throughput Screen. 2006;9:213–228. doi: 10.2174/138620706776055539. [DOI] [PubMed] [Google Scholar]
- 121.Mahmud Tareq Hassan K. Predictions of the ADMET properties of candidate drug molecules utilizing different QSAR/QSPR modelling approaches. Curr. Drug Metabol. 2010;11:285–295. doi: 10.2174/138920010791514306. [DOI] [PubMed] [Google Scholar]
- 122.Maltarollo V.G., Gertrudes J.C., Oliveira P.R. Applying machine learning techniques for ADME-Tox prediction: a review. Expet Opin. Drug Metabol. Toxicol. 2015;11:259–271. doi: 10.1517/17425255.2015.980814. [DOI] [PubMed] [Google Scholar]
- 123.Wang S., Sun H., Liu H. ADMET evaluation in drug discovery. 16. predicting hERG blockers by combining multiple pharmacophores and machine learning approaches. Mol. Pharm. 2016;13:2855–2866. doi: 10.1021/acs.molpharmaceut.6b00471. [DOI] [PubMed] [Google Scholar]
- 124.Wenzel J., Matter H., Schmidt F. Predictive multitask deep neural network models for ADME-Tox properties: learning from large data sets. J. Chem. Inf. Model. 2019;59:1253–1268. doi: 10.1021/acs.jcim.8b00785. [DOI] [PubMed] [Google Scholar]
- 125.Stratton T.P., Perryman A.L., Vilchèze C. Addressing the metabolic stability of antituberculars through machine learning. ACS Med. Chem. Lett. 2017;8:1099–1104. doi: 10.1021/acsmedchemlett.7b00299. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 126.Yang M., Chen J., Xu L. A novel adaptive ensemble classification framework for ADME prediction. RSC Adv. 2018;8:11661–11683. doi: 10.1039/c8ra01206g. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 127.Green D.V.S. Using machine learning to inform decisions in drug discovery: an industry perspective. In: Pyzer-Knapp E.O., Laino T., editors. Machine Learning in Chemistry: Data-Driven Algorithms, Learning Systems, and Predictions. American Chemical Society; Washington DC: 2019. pp. 81–101. [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.