Rapid Detection of Bifidobacterium bifidum in Feces Sample by Highly Sensitive Quartz Crystal Microbalance Immunosensor

Kaijian Hou 1,, Pingsen Zhao 2,, Yongru Chen 3,, Guiping Li 4, Yu Lin 5, Danjie Chen 6, Dan Zhu 1, Zezhen Wu 1, Danchun Lian 7, Xiaojun Huang 7, Jilin Li 7,*
PMCID: PMC7358898  PMID: 32733849

Abstract

In this work, a quartz crystal microbalance (QCM) sensor has been fabricated using immunoassay for sensitive determination of Bifidobacterium bifidum. Au nanoparticle has been used for amplifying sandwich assays. The proposed immunosensor exhibited a linear detection range between 103 and 105 CFU/mL with a limit of detection of 2.1 × 102 CFU/mL. The proposed immunosensor exhibited good selectivity for B. bifidum sensing with low cross reactivity for other foodborne pathogens such as Lactobacillus acidophilus, Listeria monocytogenes, and Escherichia coli. In addition, the proposed immunosensor has been successfully used for B. bifidum detection in feces samples and food samples. The frequency decreases of 12, 17, and 10 Hz were observed from the milk samples consisting of the mixtures of L. acidophilus, L. monocytogenes, and E. coli. The frequency decreases of 8, 15, and 7 Hz were observed from the feces samples consisting of the mixtures of L. acidophilus, L. monocytogenes, and E. coli.

Keywords: quartz crystal microbalance sensor, Bifidobacterium bifidum, immunosensor, Au nanoparticle, feces sample

Introduction

Under normal circumstances, the intestinal microorganisms in the human body form a relatively balanced state. Once the balance is damaged, it will lead to the imbalance of intestinal flora (Horie et al., 2017; Xue et al., 2018). Some intestinal microorganisms, such as Clostridium perfringens, overproduce in the intestinal tract and produce harmful substances such as ammonia, amines, hydrogen sulfide, manure, indole, nitrite, and bacterial toxins, which will further affect the health of the body (Ashida et al., 2018; Duranti et al., 2019). Bifidobacterium bifidum is an important intestinal beneficial microorganism. B. bifidum, as a physiological beneficial bacterium, has many important physiological functions for human health, such as biological barrier, anti-tumor, immune enhancement, improvement of gastrointestinal function, and anti-aging (Wang et al., 2016; Mauras et al., 2018; Din et al., 2020). B. bifidum can inhibit the growth of harmful bacteria, resist the infection of pathogenic bacteria, and synthesize vitamins needed by human body. It can promote the absorption of minerals, produce organic acids such as acetic acid, propionic acid, butyric acid, and lactic acid to stimulate intestinal peristalsis and promote defecation. It can prevent constipation, purify the intestinal environment, decompose carcinogens, stimulate the human immune system, and improve the disease resistance (Gomi et al., 2018; Bondue et al., 2019; Speciale et al., 2019). It is of crucial importance to identify B. bifidum either in food and excreta. Although the normal microbiological isolation methods have been widely used for identifying bacterial strains, they are time-consuming (Yang et al., 2017; Cheng et al., 2018; Faraki et al., 2020). Therefore, the development of a fast method for B. bifidum identification is very essential for sample scanning.

The biosensor first immobilizes the bioactive components (enzyme, antibody, tissue, cell) on the transducer. When the target analyte is recognized by the immobilized bioactive components, the biochemical reaction can be immediately converted into a quantifiable electrical signal through the transducer (Fu et al., 2015; Huertas et al., 2019; Alamgholiloo et al., 2020; Fouladgar et al., 2020; Karimi-Maleh et al., 2020). Since the rise of biosensor in the late 1960s, after nearly half a century of development, biosensor has become a comprehensive and interdisciplinary field, which is used in food safety testing, environmental testing, and clinical diagnosis. QCM is a new type of micro mass sensor based on quartz crystal resonance, which was developed in 1960s. According to the piezoelectric effect of quartz crystal, the resonance frequency of quartz crystal will change with the mass of adsorbed material, and they are in a positive proportion (Bearzotti et al., 2017; Speller et al., 2017; Wang A. et al., 2017; Ayankojo et al., 2018). QCM immunosensor is a specific biosensor combining the high sensitivity of quartz crystal and the high specificity of immune response (Bearzotti et al., 2017; Speller et al., 2017; Wang L. et al., 2017; Ayankojo et al., 2018; Zhang et al., 2018). At present, QCM immunosensor has been widely used in clinical testing, food hygiene, environmental testing, as well as other fields of chemical analysis, and biological analysis. The detection of bacteria by QCM is a new and attractive Research Topic in electronic informatics and medicine (Muckley et al., 2016; Tai et al., 2016; Chen et al., 2018; Ding et al., 2018; Lal and Tiwari, 2018; Temel et al., 2019).

In this work, a QCM immunosensor has been developed for sensitive determination of B. bifidum. Monoclonal and polyclonal antibody have been used with the signal amplifying based on the Au nanoparticle. The proposed immunosensor exhibited a wide linear detection range with a low detection of limit. The sensitivity was enhanced when the antibody-conjugated Au nanoparticle. We believe the proposed assay was validated by cross reactivity investigation using Lactobacillus acidophilus, Listeria monocytogenes and Escherichia coli.

Materials and Methods

Reagents, Bacterial Strains, and Instruments

Polyclonal antibody and mouse monoclonal antibody against B. bifidum were purchased from San Ying Biotechnology Co., Ltd (Wuhan, China). Mouse IgG, 11-mercaptoundecanoic acid (11-MUDA), bovine serum albumin (BSA), and ethanolamine hydrochloride were purchased from Linc-Bio Science Co., Ltd (Shanghai, China). Au colloidal (AuNPs) with 20 nm was purchased from Shenzhen Nano Tech Co., Ltd (Shenzhen, China). All other common regents were supplied by Sinopharm Chemical Reagent Co., Ltd (Shanghai, China) and used without further purification. A QCA922 quartz crystal analyzer (Princeton, USA) has been used for sensing with an Au coated chips. Bifidobacterium bifidum (B. bifidum), L. acidophilus, L. monocytogenes, and E. coli strains were purchased from American Type Culture Collection (ATCC, Manassas, VA). MRS (de Man, Rogosa, and Sharpe) and Bifidus Selective Medium (BSM) were used as growth media.

Sensor Chip Preparation

Piranha solution has been used for removing any impurities on the QCM Au chip. Then, the Au chip was immersed into 20 mM thiol (11-MUDA, prepared using ethanol) overnight for fabricating carboxy-terminated thiol layer on the Au surface. After rinse by ethanol and water, the Au chip was used for baseline correction under 10 mM PBS (pH 7.4). A mixture solution of EDC (0.4 M)-NHS (0.1 M) at ratio of 1:1 was then used for sensor activation. Then, different concentrations of polyclonal or mouse monoclonal antibodies against B. bifidum were immobilized on the Au chip. Then, capture and control were carried out by injected either polyclonal or mouse monoclonal antibodies and mouse IgG antibody. Then, BSA (50 μg/mL) and ethanolamine (1 M) were used for blocking and capping the sensors.

Detection of B. bifidum

Direct detection of B. bifidum was carried out by the injection of different concentrations of B. bifidum cells suspension prepared in PBS over above-mentioned polyclonal, mouse monoclonal, and mouse IgG antibodies fabricated sensor. The detection was carried out by comparing either B. bifidum captured polyclonal or mouse monoclonal antibodies with the control group.

The sandwich assay with antibody-AuNPs conjugation was prepared according to previous methods with some modifications (Uludag and Tothill, 2012). Typically, 0.1 mL of polyclonal or mouse monoclonal antibodies was added into 0.5 mL of AuNPs suspension with 2 h slow stirring. Then, 0.1 mL of BSA (10%) was introduced to the mixture with 2 h slow stirring. A centrifugation process was carried out to remove the excess of BSA and AuNPs. The detection process of using antibody-AuNPs conjugation was similar to the direct detection except the polyclonal and mouse monoclonal antibodies were replaced by the polyclonal-AuNPs and mouse monoclonal-AuNPs antibodies. Non-linear regression with four parameter logistic equations has been used for construing the calibration curves (Karpinski, 1990).

Selectivity Test

L. acidophilus, L. monocytogenes, and E. coli have been used for evaluating the specificity of the assay to B. bifidum. The selectivity test only carried out using antibody-AuNPs conjugation. The detection process of was similar to the above-mentioned protocol except replaced B. bifidum by L. acidophilus, L. monocytogenes, and E. coli.

Real Sample Preparation

The sensing of B. bifidum in milk and feces were investigated. Fresh milk was purchased form local supermarket. Feces samples were provided by The First Affiliated Hospital of Shantou University Medical College. For the sensing of B. bifidum, 1 g of real sample was dispersed using 50 mL PBS and transferred into a filtering stomacher bag. Then, 0.5 mL of the B. bifidum suspension was inoculated into both real samples at 37°C for 2 h. All liquid samples after preparation were directly used for sensing purpose.

Results and Discussion

Figure 1 shows the optimization of the immobilization of polyclonal antibody on the Au chip surface. Different concentrations of polyclonal antibody were introduced using the standard B. bifidum. As shown in Figure 1A, the frequency was initially increased when the polyclonal antibody increased from 10 to 50 μg/mL. Then, the frequency decreased when the further increase of the polyclonal antibody. Figure 1B shows the binding response of B. bifidum at these concentrations of polyclonal antibody used. It can be seen that the best response was achieved when the concentration of polyclonal antibody at 50 μg/mL. Therefore, 50 μg/mL of polyclonal antibody has been selected in this study.

Figure 1.

Figure 1

(A) Frequencies recorded at QCM when different concentrations of polyclonal antibody immobilized on the Au chip surface. (B) Frequencies performance of QCM after introduction of B. bifidum after the immobilization of different concentrations of polyclonal antibody.

Figure 2 shows the optimization of the immobilization of mouse monoclonal antibody on the Au chip surface. Different concentrations of mouse monoclonal antibody were introduced using the standard B. bifidum. As shown in Figure 2A, the frequency was initially increased when the mouse monoclonal antibody increased from 10 to 40 μg/mL. Then, the frequency decreased when the further increase of the mouse monoclonal antibody. Figure 2B shows the binding response of B. bifidum at these concentrations of mouse monoclonal antibody used. It can be seen that the best response was achieved when the concentration of mouse monoclonal antibody at 50 μg/mL. Therefore, 50 μg/mL of mouse monoclonal antibody has been selected in this study. Both studies suggested a high concentration of antibodies could result in a high steric hindrance, which lower the sensitivity of the sensor. Similar results were obtained for Campylobacter jejuni and Vibrio harveyi as well (Buchatip et al., 2010; Masdor et al., 2016).

Figure 2.

Figure 2

(A) Frequencies recorded at QCM when different concentrations of mouse monoclonal antibody immobilized on the Au chip surface. (B) Frequencies performance of QCM after introduction of B. bifidum after the immobilization of different concentrations of mouse monoclonal antibody.

B. bifidum can be directed detected using both polyclonal and mouse monoclonal antibodies immobilized Au chips. Figure 3 shows the frequency changes when different concentrations of B. bifidum introduced in the QCM system in the presence of polyclonal antibody immobilized sensor, mouse monoclonal antibody immobilized sensor, and mouse IgG antibody immobilized sensor. As shown in Figures 3B,C, sigmoidal relationship between frequency change signals and concentrations of B. bifidum were obtained for both polyclonal antibody immobilized sensor and mouse monoclonal antibody immobilized sensor. The linear portions of the concentrations of B. bifidum between 105-107 and 106-108 CFU/mL were obtained for polyclonal antibody immobilized sensor and mouse monoclonal antibody immobilized sensor, respectively. The limit of detection (LOD) of polyclonal antibody immobilized sensor and mouse monoclonal antibody immobilized sensor can be calculated to be 3.0 × 105 and 3.0 × 106 CFU/mL, respectively. Since the polyclonal antibody immobilized sensor exhibited a lower LOD, it has been further used for construction of sandwich assay.

Figure 3.

Figure 3

(A) Frequencies recorded at QCM when different concentrations of B. bifidum introduced using polyclonal antibody immobilized sensor, mouse monoclonal antibody immobilized sensor, and mouse IgG antibody immobilized sensor. Plots of Frequency vs. concentrations of B. bifidum using (B) polyclonal antibody immobilized sensor and (C) mouse monoclonal antibody immobilized sensor.

The sandwich assay has been constructed using polyclonal antibody against B. bifidum. The sandwich assay could improve sensitivity as well as prevented the false negative results (Amani et al., 2018). Figure 4A shows the sensing performance of using polyclonal antibody as the capture and detection antibody with schematic diagram. Figure 4B shows the sensing performance of using polyclonal antibody as the capture and mouse monoclonal antibody as the detection antibody with schematic diagram. It can be seen that both sandwich assay exhibited sigmoidal relationship between frequency and concentrations of B. bifidum. Linear portions of the concentrations of B. bifidum between 104-108 and 105-108 CFU/mL were observed using polyclonal antibody and mouse monoclonal antibody as the detection antibodies, respectively. The LOD of using polyclonal antibody and mouse monoclonal antibody as the detection antibodies can be calculated to be 2.0 × 104 and 3.3 × 105 CFU/mL, respectively. These results indicated that the sandwich assay could increase the sensitivity of the QCM sensor (Cervera-Chiner et al., 2018; Makhneva et al., 2018; Pohanka, 2020).

Figure 4.

Figure 4

Frequency vs. concentrations of B. bifidum using (A) polyclonal antibody and (B) mouse monoclonal antibody as the detection antibodies.

In order to further enhance the sensitivity of the QCM immunosensor, Au nanoparticles were introduced for forming the antibody-AuNPs conjugation (Zheng et al., 2015; Wang L. et al., 2017; Fu et al., 2020; Xu et al., 2020). Figure 5A shows the sensing performance of using polyclonal antibody-AuNPs conjugation as detection layer with schematic diagram. Figure 5B shows the sensing performance of using mouse monoclonal antibody-AuNPs conjugation as detection layer with schematic diagram. A linear portions of the concentrations of B. bifidum between 103 and 105 CFU/mL was observed using polyclonal antibody-AuNPs conjugation as detection layer. The LOD of using mouse monoclonal antibody-AuNPs conjugation can be calculated to be 2.1 × 102 CFU/mL. No clear linear portions of the concentrations of B. bifidum can be observed using mouse monoclonal antibody-AuNPs conjugation as detection layer. The results recorded in this study are very competitive with previous reports (Fung and Wong, 2001; Guo et al., 2012; Skládal, 2016; Della Ventura et al., 2017; Wang R. et al., 2017; Gao et al., 2018; Pohanka, 2018a,b, 2019). Table 1 showed the sensing performance comparison.

Figure 5.

Figure 5

Frequency vs. concentrations of B. bifidum using (A) polyclonal antibody-AuNPs conjugation and (B) mouse monoclonal antibody-AuNPs conjugation as the detection layers.

Table 1.

Sensing performance of the proposed QCM sensor with other reports.

Analyte Linear detection range Limit of detection References
S. paratyphi 102-105 CFU/mL 1.7 × 102 CFU/mL Fung and Wong, 2001
E. coli O157:H7 0–1 log CFU/mL Guo et al., 2012
α-Amylase 1 μg/mL Della Ventura et al., 2017
H5N1 avian influenza virus 2−4-24 HAUs/50 μL 2−4 HAU/50 μL Wang L. et al., 2017
Albumin 35–55 mg/mL 0.234 mg/mL Pohanka, 2018a
S. aureus 5.18 × 108 CFU/mL Pohanka, 2020
B. bifidum 103-105 CFU/mL 2.1 × 102 CFU/mL This work

The selectivity of the proposed QCM immunosensor has been tested by L. acidophilus, L. monocytogenes, and E. coli. As shown in Figure 6, <10% of cross reactivities were observed by L. acidophilus, L. monocytogenes, and E. coli, suggesting the proposed QCM immunosensor exhibited an excellent selectivity toward B. bifidum.

Figure 6.

Figure 6

Selectivity performance of the proposed QCM immunosensor toward B. bifidum sensing compared with that of the Lactobacillus acidophilus, Listeria monocytogenes and Escherichia coli.

The applicability of the novel QCM immunosensor to determine B. bifidum in milk and feces were also carried out. For the detection of B. bifidum in real samples, the QCM sensor was firstly calibrated by the measurement in the absence of B. bifidum. As shown in Figure 7, frequency change of 3 and 7 Hz were recorded from the milk sample and feces sample containing 104 CFU/mL of B. bifidum, respectively. These results suggested the proposed QCM immunosensor could be used for real sample test. In addition, the frequency decreases of 12, 17, and 10 Hz were observed from the milk samples consisting of the mixtures of L. acidophilus, L. monocytogenes, and E. coli. The frequency decreases of 8, 15, and 7 Hz were observed from the feces samples consisting of the mixtures of L. acidophilus, L. monocytogenes, and E. coli. The results indicate that the QCM system developed in the present study is practical for the simultaneous enrichment and detection of viable B. bifidum in real samples.

Figure 7.

Figure 7

Specific detection of 104 CFU/mL of B. bifidum, Lactobacillus acidophilus, Listeria monocytogenes and Escherichia coli inoculated on milk and feces samples.

Conclusion

In this work, an advanced piezoelectric biosensor-QCM system was proposed. In order to further enhance the sensitivity of the QCM immunosensor, Au nanoparticles were introduced for forming the antibody-AuNPs conjugation. A linear portions of the concentrations of B. bifidum between 103 and 105 CFU/mL was observed using polyclonal antibody-AuNPs conjugation as detection layer. The LOD of using mouse monoclonal antibody-AuNPs conjugation can be calculated to be 2.1 × 102 CFU/mL. The selectivity of the proposed QCM immunosensor has been tested by L. acidophilus, L. monocytogenes, and E. coli. The applicability of the novel QCM immunosensor to determine B. bifidum in milk and feces were tested. The frequency decreases of 12, 17, and 10 Hz were observed from the milk samples consisting of the mixtures of L. acidophilus, L. monocytogenes, and E. coli. The frequency decreases of 8, 15, and 7 Hz were observed from the feces samples consisting of the mixtures of L. acidophilus, L. monocytogenes, and E. coli.

Data Availability Statement

The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.

Ethics Statement

Ethical review and approval was not required for the study on human participants in accordance with the local legislation and institutional requirements. Written informed consent from the participants was not required to participate in this study in accordance with the national legislation and the institutional requirements.

Author Contributions

KH, YC, and JL contributed conception and design of the study. GL, YL, and DC conducted QCM experiments. DZ and ZW performed the statistical analysis. DL and XH did the characterizations. KH and YC wrote the manuscript. All authors contributed to the article and approved the submitted version.

Conflict of Interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

References

  1. Alamgholiloo H., Rostamnia S., Hassankhani A., Liu X., Eftekhari A., Hasanzadeh A., et al. (2020). Formation and stabilization of colloidal ultra-small palladium nanoparticles on diamine-modified Cr-MIL-101: synergic boost to hydrogen production from formic acid. J. Colloid Interface Sci. 567, 126–135. 10.1016/j.jcis.2020.01.087 [DOI] [PubMed] [Google Scholar]
  2. Amani J., Maleki M., Khoshroo A., Sobhani-Nasab A., Rahimi-Nasrabadi M. (2018). An electrochemical immunosensor based on poly p-phenylenediamine and graphene nanocomposite for detection of neuron-specific enolase via electrochemically amplified detection. Anal. Biochem. 548, 53–59. 10.1016/j.ab.2018.02.024 [DOI] [PubMed] [Google Scholar]
  3. Ashida H., Tanigawa K., Kiyohara M., Katoh T., Katayama T., Yamamoto K. (2018). Bifunctional properties and characterization of a novel sialidase with esterase activity from Bifidobacterium bifidum. Biosci. Biotechnol. Biochem. 82, 2030–2039. 10.1080/09168451.2018.1497944 [DOI] [PubMed] [Google Scholar]
  4. Ayankojo A. G., Reut J., Boroznjak R., Öpik A., Syritski V. (2018). Molecularly imprinted poly (meta-phenylenediamine) based QCM sensor for detecting Amoxicillin. Sens. Actuators B Chem. 258, 766–774. 10.1016/j.snb.2017.11.194 [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Bearzotti A., Macagnano A., Papa P., Venditti I., Zampetti E. (2017). A study of a QCM sensor based on pentacene for the detection of BTX vapors in air. Sens. Actuators B Chem. 240, 1160–1164. 10.1016/j.snb.2016.09.097 [DOI] [Google Scholar]
  6. Bondue P., Crèvecoeur S., Brose F., Daube G., Seghaye M.-C., Griffiths M. W., et al. (2019). Corrigendum: cell-free spent media obtained from bifidobacterium bifidum and Bifidobacterium crudilactis grown in media supplemented with 3′-Sialyllactose modulate virulence gene expression in Escherichia coli O157: H7 and Salmonella Typhimurium. Front. Microbiol. 10:2490. 10.3389/fmicb.2019.02490 [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Buchatip S., Ananthanawat C., Sithigorngul P., Sangvanich P., Rengpipat S., Hoven V. P. (2010). Detection of the shrimp pathogenic bacteria, Vibrio harveyi, by a quartz crystal microbalance-specific antibody based sensor. Sens. Actuators B Chem. 145, 259–264. 10.1016/j.snb.2009.12.003 [DOI] [Google Scholar]
  8. Cervera-Chiner L., Juan-Borrás M., March C., Arnau A., Escriche I., Montoya Á., et al. (2018). High fundamental frequency quartz crystal microbalance (HFF-QCM) immunosensor for pesticide detection in honey. Food Control 92, 1–6. 10.1016/j.foodcont.2018.04.026 [DOI] [PubMed] [Google Scholar]
  9. Chen W., Deng F., Xu M., Wang J., Wei Z., Wang Y. (2018). GO/Cu2O nanocomposite based QCM gas sensor for trimethylamine detection under low concentrations. Sens. Actuators B Chem. 273, 498–504. 10.1016/j.snb.2018.06.062 [DOI] [Google Scholar]
  10. Cheng R., Yao J., Wan Q., Guo J., Pu F., Shi L., et al. (2018). Oral administration of Bifidobacterium bifidum TMC3115 to neonatal mice may alleviate IgE-mediated allergic risk in adulthood. Benef. Microbes 9, 815–828. 10.3920/BM2018.0005 [DOI] [PubMed] [Google Scholar]
  11. Della Ventura B., Sakač N., Funari R., Velotta R. (2017). Flexible immunosensor for the detection of salivary α-amylase in body fluids. Talanta 174, 52–58. 10.1016/j.talanta.2017.05.075 [DOI] [PubMed] [Google Scholar]
  12. Din A. U., Hassan A., Zhu Y., Zhang K., Wang Y., Li T., et al. (2020). Inhibitory effect of Bifidobacterium bifidum ATCC 29521 on colitis and its mechanism. J. Nutr. Biochem. 79:108353. 10.1016/j.jnutbio.2020.108353 [DOI] [PubMed] [Google Scholar]
  13. Ding X., Chen X., Chen X., Zhao X., Li N. (2018). A QCM humidity sensor based on fullerene/graphene oxide nanocomposites with high quality factor. Sens. Actuators B Chem. 266, 534–542. 10.1016/j.snb.2018.03.143 [DOI] [Google Scholar]
  14. Duranti S., Lugli G. A., Milani C., James K., Mancabelli L., Turroni F., et al. (2019). Bifidobacterium bifidum and the infant gut microbiota: an intriguing case of microbe-host co-evolution. Environ. Microbiol. 21, 3683–3695. 10.1111/1462-2920.14705 [DOI] [PubMed] [Google Scholar]
  15. Faraki A., Noori N., Gandomi H., Banuree S. A. H., Rahmani F. (2020). Effect of Auricularia auricula aqueous extract on survival of Lactobacillus acidophilus La-5 and Bifidobacterium bifidum Bb-12 and on sensorial and functional properties of synbiotic yogurt. Food Sci. Nutr. 8, 1254–1263. 10.1002/fsn3.1414 [DOI] [PMC free article] [PubMed] [Google Scholar]
  16. Fouladgar M., Karimi-Maleh H., Opoku F., Govender P. P. (2020). Electrochemical anticancer drug sensor for determination of raloxifene in the presence of tamoxifen using graphene-CuO-polypyrrole nanocomposite structure modified pencil graphite electrode: theoretical and experimental investigation. J. Mol. Liq. 311:113314 10.1016/j.molliq.2020.113314 [DOI] [Google Scholar]
  17. Fu L., Yu S., Thompson L., Yu A. (2015). Development of a novel nitrite electrochemical sensor by stepwise in situ formation of palladium and reduced graphene oxide nanocomposites. RSC Adv. 5, 40111–40116. 10.1039/C5RA02661J [DOI] [Google Scholar]
  18. Fu L., Zheng Y., Zhang P., Zhang H., Xu Y., Zhou J., et al. (2020). Development of an electrochemical biosensor for phylogenetic analysis of Amaryllidaceae based on the enhanced electrochemical fingerprint recorded from plant tissue. Biosens. Bioelectron. 159:112212. 10.1016/j.bios.2020.112212 [DOI] [PubMed] [Google Scholar]
  19. Fung Y., Wong Y. (2001). Self-assembled monolayers as the coating in a quartz piezoelectric crystal immunosensor to detect Salmonella in aqueous solution. Anal. Chem. 73, 5302–5309. 10.1021/ac010655y [DOI] [PubMed] [Google Scholar]
  20. Gao K., Cui S., Liu S. (2018). Development of an electrochemical quartz crystal microbalance-based immunosensor for C-reactive protein determination. Int. J. Electrochem. Sci. 13, 812–821. 10.20964/2018.01.49 [DOI] [Google Scholar]
  21. Gomi A., Yamaji K., Watanabe O., Yoshioka M., Miyazaki K., Iwama Y., et al. (2018). Bifidobacterium bifidum YIT 10347 fermented milk exerts beneficial effects on gastrointestinal discomfort and symptoms in healthy adults: a double-blind, randomized, placebo-controlled study. J. Dairy Sci. 101, 4830–4841. 10.3168/jds.2017-13803 [DOI] [PubMed] [Google Scholar]
  22. Guo X., Lin C.-S., Chen S.-H., Ye R., Wu V. C. (2012). A piezoelectric immunosensor for specific capture and enrichment of viable pathogens by quartz crystal microbalance sensor, followed by detection with antibody-functionalized gold nanoparticles. Biosens. Bioelectron. 38, 177–183. 10.1016/j.bios.2012.05.024 [DOI] [PubMed] [Google Scholar]
  23. Horie M., Miura T., Hirakata S., Hosoyama A., Sugino S., Umeno A., et al. (2017). Comparative analysis of the intestinal flora in type 2 diabetes and nondiabetic mice. Exp. Anim. 66, 405–416. 10.1538/expanim.17-0021 [DOI] [PMC free article] [PubMed] [Google Scholar]
  24. Huertas C. S., Calvo Lozano O., Mitchell A., Lechuga L. M. (2019). Advanced evanescent-wave optical biosensors for the detection of nucleic acids: an analytic perspective. Front. Chem. 7:724. 10.3389/fchem.2019.00724 [DOI] [PMC free article] [PubMed] [Google Scholar]
  25. Karimi-Maleh H., Karimi F., Alizadeh M., Sanati A. L. (2020). Electrochemical sensors, a bright future in the fabrication of portable kits in analytical systems. Chem. Rec. [Epub ahead of print]. 10.1002/tcr.201900092 [DOI] [PubMed] [Google Scholar]
  26. Karpinski K. (1990). Optimality assessment in the enzyme-linked immunosorbent assay (ELISA). Biometrics 46, 381–390. 10.2307/2531443 [DOI] [PubMed] [Google Scholar]
  27. Lal G., Tiwari D. (2018). Investigation of nanoclay doped polymeric composites on piezoelectric Quartz Crystal Microbalance (QCM) sensor. Sens. Actuators B Chem. 262, 64–69. 10.1016/j.snb.2018.01.200 [DOI] [Google Scholar]
  28. Makhneva E., Farka Z., Skládal P., Zajíčková L. (2018). Cyclopropylamine plasma polymer surfaces for label-free SPR and QCM immunosensing of Salmonella. Sens. Actuators B Chem. 276, 447–455. 10.1016/j.snb.2018.08.055 [DOI] [Google Scholar]
  29. Masdor N. A., Altintas Z., Tothill I. E. (2016). Sensitive detection of Campylobacter jejuni using nanoparticles enhanced QCM sensor. Biosens. Bioelectron. 78, 328–336. 10.1016/j.bios.2015.11.033 [DOI] [PubMed] [Google Scholar]
  30. Mauras A., Chain F., Faucheux A., Ruffié P., Gontier S., Ryffel B., et al. (2018). A new Bifidobacteria expression system (BEST) to produce and deliver interleukin-10 in Bifidobacterium bifidum. Front. Microbiol. 9:3075. 10.3389/fmicb.2018.03075 [DOI] [PMC free article] [PubMed] [Google Scholar]
  31. Muckley E. S., Lynch J., Kumar R., Sumpter B., Ivanov I. N. (2016). PEDOT: PSS/QCM-based multimodal humidity and pressure sensor. Sens. Actuators B Chem. 236, 91–98. 10.1016/j.snb.2016.05.054 [DOI] [Google Scholar]
  32. Pohanka M. (2018a). Piezoelectric immunosensor for the determination of immunoglobulin G. Int. J. Electrochem. Sci. 13, 8784–8791. 10.20964/2018.09.01 [DOI] [Google Scholar]
  33. Pohanka M. (2018b). The determination of human albumin by a quartz crystal microbalance immunosensor. Int. J. Electrochem. Sci. 13, 8471–8480. 10.20964/2018.09.14 [DOI] [Google Scholar]
  34. Pohanka M. (2019). Piezoelectric immunosensor for the determination of c-reactive protein. Int. J. Electrochem. Sci. 14, 8470–8478. 10.20964/2019.09.02 [DOI] [Google Scholar]
  35. Pohanka M. (2020). QCM immunosensor for the determination of Staphylococcus aureus antigen. Chem. Pap. 74, 451–458. 10.1007/s11696-019-00889-5 [DOI] [Google Scholar]
  36. Skládal P. (2016). Piezoelectric biosensors. TrAC Trends Anal. Chem. 79, 127–133. 10.1016/j.trac.2015.12.00918080881 [DOI] [Google Scholar]
  37. Speciale I., Verma R., Di Lorenzo F., Molinaro A., Im S.-H., de Castro C. (2019). Bifidobacterium bifidum presents on the cell surface a complex mixture of glucans and galactans with different immunological properties. Carbohydr. Polym. 218, 269–278. 10.1016/j.carbpol.2019.05.006 [DOI] [PubMed] [Google Scholar]
  38. Speller N. C., Siraj N., McCarter K. S., Vaughan S., Warner I. M. (2017). QCM virtual sensor array: vapor identification and molecular weight approximation. Sens. Actuators B Chem. 246, 952–960. 10.1016/j.snb.2017.02.042 [DOI] [Google Scholar]
  39. Tai H., Zhen Y., Liu C., Ye Z., Xie G., Du X., et al. (2016). Facile development of high performance QCM humidity sensor based on protonated polyethylenimine-graphene oxide nanocomposite thin film. Sens. Actuators B Chem. 230, 501–509. 10.1016/j.snb.2016.01.105 [DOI] [Google Scholar]
  40. Temel F., Erdemir S., Ozcelik E., Tabakci B., Tabakci M. (2019). Rapid and real-time detection of arginine enantiomers by QCM sensor having a Calix [4] arene receptor bearing asymmetric centers. Talanta 204, 172–181. 10.1016/j.talanta.2019.05.093 [DOI] [PubMed] [Google Scholar]
  41. Uludag Y., Tothill I. E. (2012). Cancer biomarker detection in serum samples using surface plasmon resonance and quartz crystal microbalance sensors with nanoparticle signal amplification. Anal. Chem. 84, 5898–5904. 10.1021/ac300278p [DOI] [PubMed] [Google Scholar]
  42. Wang A., Wang C., Fu L., Wong-Ng W., Lan Y. (2017). Recent advances of graphitic carbon nitride-based structures and applications in catalyst, sensing, imaging, and LEDs. Nano-Micro Lett. 9:47. 10.1007/s40820-017-0148-2 [DOI] [PMC free article] [PubMed] [Google Scholar]
  43. Wang G.-H., Chen C.-Y., Lin C.-P., Huang C.-L., Lin C., Cheng C.-Y., et al. (2016). Tyrosinase inhibitory and antioxidant activities of three Bifidobacterium bifidum-fermented herb extracts. Ind. Crops Prod. 89, 376–382. 10.1016/j.indcrop.2016.05.037 [DOI] [Google Scholar]
  44. Wang L., Wang Z., Xiang Q., Chen Y., Duan Z., Xu J. (2017). High performance formaldehyde detection based on a novel copper (II) complex functionalized QCM gas sensor. Sens. Actuators B Chem. 248, 820–828. 10.1016/j.snb.2016.12.015 [DOI] [Google Scholar]
  45. Wang R., Wang L., Callaway Z. T., Lu H., Huang T. J., Li Y. (2017). A nanowell-based QCM aptasensor for rapid and sensitive detection of avian influenza virus. Sens. Actuators B Chem. 240, 934–940. 10.1016/j.snb.2016.09.06723202345 [DOI] [Google Scholar]
  46. Xu Y., Lu Y., Zhang P., Wang Y., Zheng Y., Fu L., et al. (2020). Infrageneric phylogenetics investigation of Chimonanthus based on electroactive compound profiles. Bioelectrochemistry 133:107455. 10.1016/j.bioelechem.2020.107455 [DOI] [PubMed] [Google Scholar]
  47. Xue M., Ji X., Liang H., Liu Y., Wang B., Sun L., et al. (2018). The effect of fucoidan on intestinal flora and intestinal barrier function in rats with breast cancer. Food Funct. 9, 1214–1223. 10.1039/C7FO01677H [DOI] [PubMed] [Google Scholar]
  48. Yang D., Wu X., Yu X., He L., Shah N. P., Xu F. (2017). Mutual growth-promoting effect between Bifidobacterium bifidum WBBI03 and Listeria monocytogenes CMCC 54001. J. Dairy Sci. 100, 3448–3462. 10.3168/jds.2016-11804 [DOI] [PubMed] [Google Scholar]
  49. Zhang D., Wang D., Zong X., Dong G., Zhang Y. (2018). High-performance QCM humidity sensor based on graphene oxide/tin oxide/polyaniline ternary nanocomposite prepared by in-situ oxidative polymerization method. Sens. Actuators B Chem. 262, 531–541. 10.1016/j.snb.2018.02.012 [DOI] [Google Scholar]
  50. Zheng Y., Fu L., Han F., Wang A., Cai W., Yu J., et al. (2015). Green biosynthesis and characterization of zinc oxide nanoparticles using Corymbia citriodora leaf extract and their photocatalytic activity. Green Chem. Lett. Rev. 8, 59–63. 10.1080/17518253.2015.1075069 [DOI] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.


Articles from Frontiers in Chemistry are provided here courtesy of Frontiers Media SA

RESOURCES