Abstract
It is extremely challenging to chemically diagnose disorders of the brain. There is hence great interest in designing and optimizing tools for direct detection of chemical biomarkers implicated in neurological disorders to improve diagnosis and treatment. Tools that are capable of monitoring brain chemicals, neurotransmitters in particular, need to be biocompatible, perform with high spatiotemporal resolution, and ensure high selectivity and sensitivity. Recent advances in electrochemical methods are addressing these criteria; the resulting devices demonstrate great promise for in vivo neurotransmitter detection. None of these devices are currently used for diagnostic purposes, however these cutting-edge technologies are promising more sensitive, selective, faster, and less invasive measurements. Via this review we highlight significant technical advances and in vivo studies, performed in the last 5 years, that we believe will facilitate the development of diagnostic tools for brain disorders.
Keywords: serotonin, dopamine, glutamate, acetylcholine, voltammetry, biosensor
Graphical Abstract
Introduction
Unlike illnesses of the body, such as diabetes or cancer, disorders of the brain, such as depression, do not have defined diagnostic protocols with quantifiable chemical biomarkers. The inability to definitively diagnose mental disorders means that it is also difficult to effectively treat them: antidepressants, for example, are largely ineffective for the majority of patients.1 There is, thus, enormous interest by us and others to identify chemical biomarkers of brain disorders so that illnesses of the brain can be better diagnosed and treated.
Biomarkers of brain disorders have been difficult to identify for two primary reasons. First, the blood brain barrier maintains strict and different chemical climates between the brain and the periphery, such that peripheral blood does not reflect the brain’s chemical microenvironment. Secondly, it is extremely difficult to probe the chemistry, namely neurotransmission, of an intact brain (in vivo). Analysis of neurotransmission necessitates micro or nano level spatial resolution, which is particularly challenging given the intricate nature of brain tissue. Additionally, the brain is chemically harsh and complex and neurotransmission is dynamic (occurring on the sub-seconds).
In the last decade, microengineering is the cutting-edge method to produce devices that are small, fast, and chemically reactive enough to meet some of the challenges of measuring neurotransmitters in vivo. There are three main categories of in vivo neurotransmitter detection devices; fluorescence probes, sampling (e.g. microdialysis), and electrochemistry. There are distinct pros and cons for each class of method, however electrochemical methods are particularly suited to in vivo sampling because they are able to perform direct chemical measurements in deep brain tissue without the need for artificial tags or sample treatment/analysis.
Via this review, we highlight the most recent advancements in the development of electrochemical microdevices over the last five years in the detection and quantitation of various important neurotransmitters to brain disorders, including glutamate (Glu), acetylcholine (ACh), dopamine (DA) and serotonin (5-HT). We focus mostly on amperometric biosensors and voltammetry in this review. While most of the literatures cited are primarily performed in vivo, we choose to highlight some in vitro and ex vivo work that further the progress of the field as well as display promising potential for future in vivo experiments.
While few of the reviewed methods have been implemented in humans and none have been used for diagnostics, we believe these devices show promise towards rapidly enabling chemical biomarker identification in the brain. Such a transition will revolutionize diagnosis and treatment of disorders of the brain.
Monitoring Neurotransmission
Neurotransmitters are small molecules that relay chemical messages between brain cells via a process called neurotransmission (Figure 1). As such, the intricacies of neurochemical signaling are of particular interest in the diagnosis and treatment of psychological disorders. Neurotransmission is rapid (milliseconds) and occurs over several general steps. First, the transmitter is synthesized via presynaptic processes. Release of neurotransmitter from the presynaptic cell into the synaptic space is via Ca2+ initiated exocytosis. Following release, the transmitter binds to receptors on the postsynaptic cell or to autoreceptors on the presynaptic cell. Finally, the signal is terminated through reuptake back into the presynaptic cell by a transporter, followed by intracellular catabolism or via direct extracellular catabolism.
Figure 1.
Illustration of a synapse. Presynaptic cell is on the left and postsynaptic cell is on the right. Green spheres represent neurotransmitters. Autoreceptors are shown in orange and postsynaptic receptors in purple.
Classical neurotransmission is mediated by excitatory neurotransmitters such as Glu and ACh and the inhibitory neurotransmitter gamma-aminobutyric acid (GABA), which, because of their potency and cytotoxicity, are confined to the synaptic space. Neuromodulators, such as DA, 5-HT, norepinephrine, and histamine (HA), are types of neurotransmitters that signal through “volume transmission.” Unlike Glu, ACh and GABA, these molecules diffuse outside of the synapse exerting influence over many cells over a large spatial area.
This review explores electrochemical neurotransmitter measurements in the context of neurotransmission. Two categories of electrochemical techniques are of particular interest: voltammetry and biosensors. Within these two categories we also discuss simultaneous measurement of analytes and the integration of a chemical sensing device with other types of electrical measurements such as electrophysiology.
Voltammetry
A variety of voltammetric techniques are utilized to directly detect electroactive molecules. These techniques are characterized by the application of a potential waveform to an electrode and the measurement of the resulting current.2 Because of the rapid time frame of neurotransmission, fast-scan cyclic voltammetry (FSCV) is of particular interest throughout this review. In FSCV, a waveform with a fast scan rate is applied to a microelectrode, at high frequency (typically 10Hz), affording measurements with millisecond timescale.3 This method is coupled to carbon fiber microelectrodes (CFMs) of 5–7 μm in diameter. This small probe size promotes high spatial resolution and negligible tissue damage.4 Figure 2 shows the two electron oxidation/reduction of DA at a CFM that results in a stereotypical DA fast scan cyclic voltammogram. There are some drawbacks to FSCV measurements. Firstly, a limited number of neurotransmitters have electroactivity that lends itself to FSCV detection. This issue has made detection of neurotransmitters such as Glu, GABA, and ACh difficult. Selectivity is also a concern; the monoamines DA, 5-HT, and norepinephrine oxidize at similar potentials and are colocalized in many of the same brain regions. In many cases, waveform optimization and pharmacological manipulation are implemented to differentiate between the molecules and to reduce signals due to other interferents. This review will explore advancements made in FSCV to address existing limitations and to provide additional insight into the complexities of neurotransmission.
Figure 2.
Schematic of FSCV at CFMs. The top shows the waveform. The blue box shows the parameters of the waveform. In the middle is an illustration of a CFM performing a two-electron oxidation/reduction of DA with a representative cyclic voltammogram to the right.
Biosensors
When the analyte of interest is not easily electroactive, biosensors can be applied. Biosensors are devices that create an electrical signal in response to the analyte via a biocatalyst such as an enzyme, antibody or DNA.5 Electrochemical biosensors commonly involve immobilization of an enzyme at an electrode surface. This enzyme is selective for an analyte of interest. As an example, the enzyme Glu oxidase oxidizes Glu and reduces O2 to H2O2. While Glu is not readily electroactive, H2O2 can be easily oxidized. Thus amperometry (current measured at constant potential) can quantify Glu via H2O2 oxidation. A generalized biosensor scheme is shown in Figure 3. The major advantages of biosensors are the high selectivity afforded by the biological molecule and electrochemical detection of chemicals that are not electroactive within the potential window of traditional electrode materials. However, the use of enzymes produces many challenges. Sufficient enzyme loading for high sensitivity, membranes and immobilizing matrices often necessitates large probes, which is undesirable for measurement in delicate brain tissue.6 Additionally, immobilization methods can cause conformational changes in the enzyme, lowering catalytic activity, stability and shelf-life.7 Efforts to overcome these obstacles for in vivo measurements are highlighted throughout this review.
Figure 3.
Schematic of an electrochemical biosensor. A typical biosensor consists of a biorecognition element selective for the molecule of interest (blue triangles) within a given matrix (red squares and green circles), a transducer that converts the input into a measurable signal, and signal processing and output components.
Glutamate (Glu)
Introduction
Glu is one of the most ubiquitous neurotransmitters8 that binds to NMDA (N-methyl-D-aspartate), kainate, AMPA (α-amino-3-hydroxy-5-methyl-4-isoxazole-propionic acid), and metabotropic receptors.9 Because Glu is highly excitatory, this messenger can exert excitotoxic effects and is thus rapidly uptaken via excitatory amino acid transporters located on the plasma membrane of astrocytes and neurons.10, 11 This high level of regulation presents difficulties for analytical Glu measurements since Glu cannot readily escape the synapse like the neuromodulators described later in this review. Additionally, Glu is not electroactive within the potential window of conventional electrode materials. These two phenomena present unique challenges for Glu detection.
The extraction and purification of Glu oxidase12 enabled development of selective Glu biosensors, the frontline electrochemical Glu detection devices. Working electrodes in these sensors can be made from carbon fiber13 or diamond14 but are most commonly composed of platinum.15 Substrate materials for creating sensing platforms, including arrays, are primarily silicon or ceramic.16 Strategies for immobilizing the enzyme onto the electrode surface include direct adsorption, covalent binding, cross-linking,17 and entrapment in polymers (reviewed in Scouten et al.,18 Freire et al.,19 Putzbach et al.20 and Hughes et al.21). Immobilization of enzymes in polymeric membranes, especially electrochemically deposited polymers,22–34 gained increasing attention due to a variety of factors,23 particularly the ability to prevent interfering molecules from reaching the electrode. Self-referencing is another strategy used to reduce signals from other electrochemically active species.34–36 This approach involves a second electrode that mimics the working electrode in all respects but does not contain enzyme. This ensures that signals from any non-selective binding of species to the electrode surface can be subtracted out.
One major limitation for biosensors is poor electron transfer between the enzyme and the electrode due to the tunneling distance between the enzyme’s electron transfer center and the electrode. To improve signal transduction, various functional nanomaterials37–40 and redox mediators41–43 were incorporated into the electrode design.44 Using these general strategies, Glu biosensors were utilized to investigate the dynamics of this messenger in the brain.
Glutamate in Sleep/Wake and Reward
Electrochemical measurement of Glu could have implications for diagnosis of sleeping and addictive disorders. Glu biosensors have been used in the mouse prefrontal cortex (PFC) to investigate Glu’s roles in the sleep/wake cycle. For example, Naylor et al. found that extracellular Glu levels correspond well to the sleep/wake cycle. Glu levels were higher during the awake state and lower during the sleep state with transients during periods of REM sleep.45 Further work found chronically high levels of extracellular Glu in the same brain region in animal models with Rett syndrome, who demonstrated severe sleep deprivation-like symptoms.46
Glu biosensors have also been utilized to investigate reward circuitry. An initial dose of nicotine induced rapid, transient Glu release in the ventral tegmental area and the nucleus accumbens, regions that make up the mesolimbic system, a neural system highly implicated in reward.47 Cocaine administration induced similar phasic Glu release in the nucleus accumbens shell.48 Repeated doses of nicotine increased the tonic Glu that correlated with drug-induced hyperlocomotion.47 Repeated doses of cocaine had similar effects in the dorsal striatum49 and an interesting biphasic release profile in the nucleus accumbens shell.48 Wassum et al. measured rapid Glu transients prior to lever pressing in rodent models of reward-seeking behavior.33, 50 These studies generally implied a role for Glu in cue-evoked reward behaviors; however, a 2015 study showed that Glu release from selective activation of glial cells inhibited reinstatement of cocaine seeking behavior.51 Thus, Glu’s roles in reward seeking are clearly complicated and warrant more investigations.
Technological advances over the last five years include using novel materials to enhance sensitivity, stability, response time, and cost effectiveness of these sensors. There has also been a push to address the oxygen-sensitivity of glutamate sensors by replacing glutamate oxidase with other enzymes. Additionally, it is clear that other analytes and chemicals work in tandem with Glu. Thus, there is a need for multi-analyte measurements and integrated devices. We review novel technical advancements below.
Novel Technical Advancements for Glutamate Biosensors
Materials
Novel materials have been used in recent years to enhance the intrinsic properties of Glu biosensors. The first generation of Glu biosensors utilize molecular oxygen as the electron acceptor to form H2O2, which is electrochemically detected. Accurate measurements of Glu in oxygen-poor environments, such as hypoxia, thus pose a problem. To tackle this, researchers turned to cerium oxide, a co-immobilization material that can trap and release oxygen from its crystalline structure.52 Shi et al. developed second generation biosensors using chitosan as a directional immobilization matrix for both Glu oxidase and redox mediators.53 These matrices are particularly useful for small electrode areas that cannot be drop-coated or screen-printed. The group found that immobilization via chitosan provided faster response times than sensors cross-linked to the electrode via the traditional glutaraldehyde linker.54
Weltin et al. used a flexible polyimide-based substrate as the wafer for sensor design, instead of the more rigid silicon or ceramic alternatives. The authors pointed out that soft materials cause less tissue damage and demonstrated the utility of this sensor by measuring Glu in vivo.55 In a follow-up study, the same group created multiparametric devices via hybrid thin-film and laminate technology using polyimide substrates.56 The device included sensors for Glu, lactate, oxygen, and glucose detection simultaneously.
The polymers used for biosensors are also important. Clay et al. recently developed a mathematical model for optimizing conditions of electroenzymatic sensors for optimal Glu detection. The model accurately predicted the sensitivity for Glu sensors made by immobilizing Glu oxidase with various polymeric films. Simulations demonstrated that a significant amount (>95%) of H2O2 generated in the thick enzyme layers tend to diffuse back to the sample solution, suggesting that biosensors made with thinner films (1–3 μm) were optimal. In fact, the simulations showed that these films would yield several-fold improvement in both sensitivity and response time. The model was for a specifically constructed device; however, it can be used as a blueprint for optimizing other enzyme-based biosensors.57
Other notable examples of novel materials include hybrid carbon materials by Sainio et al., who demonstrated that electrodes made with tetrahedral amorphous carbon nanofibers had a larger potential window than conventional electrode materials and could measure Glu without enzymes.58 Nasr et al. developed a borosilicate micropipette-based biosensor covered with self-organized nanostructures, whose large surface area increased sensitivity for Glu detection in stem cell-derived brain organoids.59
New Enzyme Alternatives
Oxygen is an important consideration in glutamate sensing. First-generation sensors require oxygen to function while second-generation sensors use artificial redox mediators, which oxygen competes with. Thus, a limitation of first-generation glutamate sensors is oxygen deprivation while a limitation of second-generation sensors is oxygen interference (reviewed in Jamal et al.60). One way to overcome these issues is to replace the glutamate oxidase enzyme in these sensors with other enzymes. The most common approach has been to replace glutamate oxidase with glutamate dehydrogenase.61–63 Wu et al. recently discovered that ferredoxin-dependent glutamate synthase also has bioelectrocatalyst properties and can be tuned to either catalyze glutamate synthesis or glutamate oxidation by careful selection of redox mediators.64 This discovery is notable for a new generation of glutamate biosensor design because 1) it overcomes the oxygen sensitivity seen in previous generations and 2) since the redox-active region is close to the surface of the enzyme, it provides a method that allows for direct electron transfer between the enzyme and the electrode surface.
Multi-modal and Integrated Glutamate Measurements
An ongoing challenge for electrochemical sensor design is to measure both electroactive and non-electroactive neurotransmitters with the same device. Moore et al. used a commercially available Glu biosensor, incorporating ascorbic acid (AA) oxidase (to inactivate this interfering species) and measured DA and Glu at constant potential. Although there is less selectivity when using fixed potential instead of FSCV, the authors argued that it is a worthy trade-off to be able to detect multiple neurotransmitters at the same device. The group used this technique to measure phasic and tonic changes in Glu and DA during sexual behavior of hamsters.65 In a similar approach, Massicote et al. created a novel complementary metal-oxide-semiconductor amperometric system for multi-electrode measurements of DA and Glu.66 Like Moore et al., this group recognized the reduced selectivity with constant potential detection of DA and proposed the use of adaptable carbon nanotube-based coatings for reducing interferences. Ferreira et al. created microbiosensors for ascorbate and Glu, and then combined the two in an array for simultaneous measurements in vivo.67 Figure 4 shows the CFM (left) modified with Nafion™ and single-walled carbon nanotube (with an LOD of 0.7 μM) for ascorbate sensing and ceramic microelectrode arrays (right) for Glu sensing. The middle is a micropipette for delivering local stimulus solution.
Figure 4.
Schematic representation of array composed by ascorbate nanocomposite microsensor (left), Glu microbiosensor (right) and the micropipette (center) for local application of solutions in the extracellular space of the rat hippocampus. Reproduced from Ferreira et al. with permission.67
Electrophysiology is one of the most commonly used techniques in neuroscience and monitors neuronal activity as a function of a DC shift. Wei et al. developed silicon-based implantable microelectrode arrays with a micro-electromechanical system technology for simultaneous in vivo Glu and electrophysiological recordings in the striatum of anesthetized rats.68 In a similar approach, Fan et al. created a 16-channel silicon-based array based on micro-electromechanical system technology. Twelve of the 16 electrodes were modified with platinum black, a “spongy” electrode material with excellent catalytic properties, for electrophysiological recordings of neural firing. The remaining 4 electrodes were modified with Glu oxidase for Glu measurements in vivo. This microelectrode array was implanted into the cortex and hippocampus of mice and Glu concentrations were found to be higher in the hippocampus despite slower firing rates of neurons.69
Acetylcholine (ACh)
Introduction
ACh binds to two main classes of receptors: nicotinic and muscarinic. Ionotropic nicotinic receptors are present in relatively low abundance in the brain, with the majority of cholinergic receptors being metabotropic muscarinic receptors.70 Furthermore, ACh is unique among neurotransmitters because the ACh’s signal is terminated exclusively through extracellular degradation of the molecule via acetylcholinesterase in the synapse that rapidly breaks down this molecule into choline and acetate. Choline is then taken up by the presynaptic cell. Because ACh is not electroactive within the potential window of most biocompatible materials, efforts to measure the molecule have mostly focused on the exploitation of ACh metabolism. Electrochemical enzyme-based sensors for ACh have been developed using either choline oxidase or a combination of acetylcholinesterase and choline oxidase. Enzymes are immobilized on the electrode surface via different approaches and the catalytically generated H2O2 is detected amperometrically.71
Duel-enzyme biosensors measured the sum of choline and ACh signals via choline oxidase and acetylcholinesterase enzymes.72 To refine this approach, self-referencing sensors, with separate sites for ACh/choline and choline detection, allowed interfering signals to be subtracted out and independently quantify choline and ACh signals in vivo.73, 74
In terms of unraveling ACh’s role in the brain using biosensors, Parikh et al. were the first to use a simpler single sensor approach of measuring choline in awake, behaving animals. The electrode was modified with choline oxidase, assuming choline is a direct index of ACh.75 The keynote studies from this group laid the foundation for investigating ACh’s roles in attention and memory, the most recent of the findings of which are reviewed below.
Acetylcholine’s Role in Attention and Memory
ACh measurements with electrochemical devices may prove critical in diagnosis of attention and memory disorders, including neurodegenerative diseases such Alzheimer’s disease. ACh biosensors have time resolution on the order of seconds or subseconds and have been able to capture transient changes in ACh concentration.75, 76 For example, cholinergic transients associated with attentional performance in cue detection behavioral tasks were measured in the PFC of rodents.77 In this experiment, animals responded to a visual light cue by pressing an assigned lever for a food reward. The evidence presented in the paper suggested that choline plays a role in switching from monitoring a response to acting upon it.77 In a follow up study, optogenetic stimulation of cholinergic transients increased the probability of correctly acting upon a response.78 The same group used combined approaches (choline measurements, electrophysiology and pharmacology) to show that cholinergic transients were concomitant with increased neuronal synchronicity across several neuronal firing frequency bands and the emergence of theta–gamma coupling (a neurophysiologic process underlying working memory).79 Thus the group revealed the important role that ACh may play in linking attention to memory.79 Synchronized release of ACh has also been observed across brain regions; Teles-Gilo Ruivo et al. used a dual-enzyme biosensor to measure coordinated ACh release in the PFC and hippocampus of freely moving mice performing a working memory task.80
While there have been exciting advancements in the detection of choline and ACh, there are existing difficulties in in vivo measurements. Technological advances in the last five years attempted to address some of these, including probe size, stability, temporal resolution, and toxicity. These are addressed in the following section. Some of the papers described are designed for environmental studies but the technical innovations, we believe, can be applied to future in vivo sensor design.
Frontiers in Acetylcholine Biosensing
Acetylcholine Measurements on a Nano Level
A novel nanopipet-based electrode addressed size limitations associated with ACh measurements.81 Photograph and scanning electron micrograph of this small probe can be seen in Figure 5A and 5B, respectively. This electrode utilized assisted ion transfer at nanopipettes combined with cyclic voltammetry (Figure 5C) and amperometry. The probe was filled with an organic solvent and implanted into an aqueous environment, which is immiscible with the fill solution in the probe. The pipet supported the interface between two immiscible electrolyte solutions (ITIES) and measured ion transfer across a liquid-liquid interface rather than a redox process, allowing for traditionally non-electroactive molecules to be quantitatively measured. The electrodes ranged in size from ~14 to 70 nm in diameter, significantly smaller than the traditional microelectrode. These nanoITIES electrodes were used to measure ACh release from both the soma and a single synapse of Aplysia californica cells.82, 83 A concentration of 2.7 ± 1.0 μM released ACh was measured from a single soma, with a releasable vesicle density of 25 ± 2 vesicles per μm2.
Figure 5.
(A) Photograph and (B) scanning electron micrograph of a nanopipet prepared by a laser-pulled capillary. (C) Cyclic voltammogram of 2 mM acetylcholine (ACh), tetraethylammonium (TEA), and artificial seawater (ASW). TEA was used as an internal standard and ASW was the solvent (background signal). Adapted with permission from Colombo et al.81
Stability
An ongoing issue with ACh biosensors is poor stability and longevity due to loss of enzyme activity. Baker et al. utilized stabilizing agents, including methyl methacrylate, cellulose acetate, bovine serum albumin, glutaraldehyde, and polyethyleneimine that permitted stable, chronic in vivo implantation of choline sensors up to 14 days.84 Kanik et al. used the conjugated polymer poly(4-(2,5-di(thiophen-2-yl-)-1H-pyrrol-1-yl) benzamine) to create both mechanically and chemically stable biosensors without the need for redox mediators.85 Utilizing carbon nanospheres that create unique 3D structures for high enzyme entrapment, Cai et al. created an ACh sensor that maintained 80% of its response after 20 days.86 A different approach was to entrap acetylcholinesterase within a hybrid silica mesoporous membrane, which, due to its large interconnected pores, enabled high enzyme loading and minimized denaturing.87 This sensor maintained 90% of its response after 60 days of storage. Even longer sensor lifetimes, up to 4 months, have been reported.88
Temporal Resolution
Santos et al. created a choline biosensor with a temporal resolution of 1.4 s.89 This sensor was composed of two 50 μm diameter Pt/Ir disks constructed side-by-side with choline oxidase immobilized onto the electrode surfaces with chitosan as the matrix and p-benzoquinone as the linker. This sensor provided high spatiotemporal resolution for spontaneous choline measurements in sub-regions of the hippocampus.89 Mousavi et al. created a potentiometric ionophore-doped ion-selective electrode which did not require enzyme modification.90 The potentiometric method measured the partition of the cationic 5-HT molecule between the sample and a hydrophobic ion-selective membrane doped with calixarene, a hydrophobic molecule whose binding cavity mimics that of acetylcholinesterase. This sensor had a response time of < 1 second and was used successfully in rat brain homogenates. Keighron et al. modified carbon fiber microdisk electrodes with spatially discrete nanoparticles, onto which acetylcholinesterase and choline oxidase were deposited.91 The enzyme layer was near monolayer thickness, allowing for rapid (millisecond) response time, the fastest reported for biosensing tools. This technique was used to measure exocytotic ACh release from artificial secretory cells.
Green Acetylcholine Detection
A fast-growing interest for sensor design is sustainability. For biosensors this means renewable enzyme interfaces for reusable sensors. Zhang et al. used the layer-by-layer self-assembly technique to create a renewable ACh biosensor.92 The enzyme interfaces were renewed by treatment with NaOH and fresh layers of multi-walled carbon nanotubes with polyethylenediamine and acetylcholinesterase. Researchers are also increasingly interested in the use of safe materials. The immobilization and interference rejection polymer poly-phenylenediamine has been suggested to be carcinogenic.93 Phenol-derived films93 as well as nanocomposites, made of gold-coated iron oxide nanoparticles with chitosan,94 show promise for safe materials. Using these materials, Chauhan et al. created an iron oxide nanoparticle poly(3,4-ethylenedioxythiophene)-reduced graphene oxide nanocomposite modified fluorine doped tin oxide biosensor for rapid (4 s), sensitive (4 nM) ACh detection in serum.95
Dopamine (DA)
Introduction
DA is a neuromodulator and is released, by the fusion of pre-synaptic vesicles to the cell membrane, in the extracellular space. DA and exerts its effects, via volume transmission, to modulate the function of other neurotransmitters. DA has five major receptor subtypes (D1-D5) and is regulated via autoreceptors, heteroreceptors, and transporters.96
CFMs were discovered to be useful sensors for in vivo DA measurements due to their biological compatibility97, 98 and renewable surfaces.99, 100 Early days of DA measurements were plagued by interferences, particularly significant contribution from AA, which is present in much higher quantities in the brain than DA.101 However, it was demonstrated that holding the potential at −0.4 V preconcentrates the positively charged DA ion,102 and increasing scan rate allows DA oxidation (whose electron transfer kinetics are faster than that of AA) to overshadow AA oxidation.103 New instrumentation was created to simplify measurements and data analysis.104 Dopamine was measured with FSCV as evoked with electrical stimulation,105 and Rebec et al. were the first to observe DA transients during behavior.106 We know precipitously more about the functions of DA in the brain than other transmitters because of this breakthrough technique, typified by the work of Mark Wightman over the last four decades. These works have enabled routine study of DA by many members of the community.
Dopamine in Cognition and Reward
Electrochemical devices that measure DA have wide reaching diagnostic potential, for example in addictive and cognitive disorders and neurodegenerative diseases such Parkinson’s disease (characterized by loss of DA neurons). DA FSCV technology described above culminated, among other seminal findings, in establishing DA’s major roles in reward and cognition.107–115 These findings spearheaded an explosion of studies to understand these behaviors in the context of the dopaminergic system. In particular, it was found that the reward-related behaviors described above are controlled by the mesolimbic DA circuits, which are in turn modulated by endogenous factors such as hormones. Naef et al. showed that insulin administration reduced DA release in the nucleus accumbens as well as attenuated cocaine-induced DA spikes and locomotor hyperactivity.116 The hormone estradiol has was found to increase the DA mediated potency of cocaine,117 a finding that could explain the sexual dimorphism in addiction vulnerability. Another interesting finding has been that the stress hormone corticosterone potentiates DA signaling via inhibition of the organic cation transporter (OCT) 3, which may explain stress-induced drug relapse behavior.118
Other notable investigations involving DA FSCV include measuring this modulator in humans playing a reward based investment game during surgery for deep brain stimulation for Parkinson’s disease119 and after administration of chemotherapy drugs in a zebra fish model of chemo brain.120–122 An additional recent direction is deciphering DA/5-HT modulation in the context of alcohol consumption123 and response to neutral stimuli in animal models.124
Recent technical advances in the last five years, including improvement of calibration, measurement of ambient DA levels, monitoring multiple analytes simultaneously, chronic measurements, and integrating in vivo voltammetry with other platforms are highlighted below.
Technical Advancements
Calibration
Calibration is an ongoing issue for FSCV. CFMs are typically fabricated in-house; thus calibration of each electrode is necessary to ensure quality. There is ongoing discussion in the field as to whether to employ pre- or post- experiment calibrations. In either case, in vitro calibrations do not reflect the in vivo performance of the electrode. This is because calibrations are performed in buffer solutions that cannot replicate the in vivo environment. Additionally, in vivo proteins adsorb to and foul electrodes, resulting in loss of sensitivity. Furthermore, in most experiments, the tip of the electrode must be exposed to a high enough potential to lesion the surrounding tissue for location determination, a process that renders post-calibrations impossible.125, 126 To overcome these issues, various mathematical tactics have been employed.
Via a total-background-current strategy, Roberts et al. created a quadratic model relating sensitivity to background current and switching potential.125 The group showed that the model was a good predictor of in vivo sensitivity. An alternative approach is to use principal component regression, which captured information from the shape of the background current to better provide estimates of sensitivity.126 Meunier et al. built upon this principal component regression strategy by modeling impedance changes due to electrode fouling with simple circuits, thereby improving the accuracy of predicted background current.127
Chronic Dopamine Measurements
The majority of in vivo FSCV studies span 4–8 hrs. There is great interest to make measurements at a CFM in the same position over an extended period of time to understand neurochemical changes during behavior and/or chronic pharmacological manipulations. Chronic measurements have been a topic of interest for some time, for a discussion of chronic FSCV methods before 2013, we refer the reader to a review by Wightman and colleagues.128
One of the chief issues with chronic measurements is the loss of electrode material over time.100 Nimbalkar et al. designed and fabricated a new class of homogeneous glassy carbon neural probes with no adhesion or conducting metal layers, thereby enhancing the lifetime of the probe for long periods of electrical stimulation (for deep brain stimulation, for example).129 Interestingly, the same probe materials were capable of stimulating in addition to performing neurochemical measurements.129
Another hindrance to using traditional FSCV carbon fiber probes for chronic measurements is the size of the probe shaft, which induced inflammatory responses. While the probe tip was on the order of 5–7 μm, the probe shaft can be as large as 100 μm. Inflammatory responses can foul the electrode surface, reducing the lifetime of the electrode. Schwerdt et al. recently replaced the glass shaft of the conventional CFMs with parylene, which provides robustness in a thinly deposited layer surrounding the carbon fiber, resulting in <10 μm size probe shafts. These probes were fabricated into arrays and implanted in rodent,130 and non-human primate131 brains for successful multi-channel simultaneous DA measurements for over 100 days in vivo.
Ambient Dopamine Levels
FSCV is background-subtracted because of a large double layer charging current that results from application of fast scan rates. Because of this, a change must be evoked in the system, usually via electrical stimulation. Background subtraction has thus prevented measurement of tonic or ambient, steady state levels of neurotransmitters in vivo. In 2012, the Wightman group utilized pharmacology to report tonic DA levels at around 20 nM.132 The following text highlights recent approaches to measuring ambient DA levels.
Atcherley et al. modified FSCV and coined a novel method, fast-scan controlled-adsorption voltammetry (FSCAV).133 Figure 6 shows that DA FSCAV takes place over three distinct steps: 1) The triangle waveform (−0.4 to 1.3 V, scan rate = 1200 Vs−1) was applied at a high frequency of 100 Hz to minimize adsorption of DA to the electrode surface (A, purple region); 2) a fixed potential (−0.4V) was applied to the electrode system, allowing for DA to adsorb to the electrode surface for a controlled amount of time (A, blue region); and 3) the waveform was then reapplied at the same frequency to measure the adsorbed DA (A, green region). Figure 6B shows a representative color plot, from which the first current vs. time curve with the representative DA peak (Figure 6C) is used to quantify the total charge underneath the peak. Total charge was then plotted against concentration (Figure 6D) to generate a calibration curve.
Figure 6.
FSCAV was carried out in 3 steps (A): 1) The waveform was applied every 10 millsecond which minimizes DA adsorption to the electrode. 2) The potential was held at −0.4 V for 10 seconds to allow DA to adsorb to the electrode and reach equilibrium. 3) The waveform was reapplied, and the adsorbed DA was measured. Surface-accumulated DA (ΓDA) is proportional to the tonic concentration [DA] by the strength of adsorption. (B) Resultant color plot from step 3, with voltage on the ordinate, time on the abscissa, and current displayed using false colors. (C) Representative current trace (red) taken 10 millsecond after the beginning of step 3. The vertical dashed lines show the bounds for integration to quantify adsorbed DA. The grey-dashed triangles illustrate the voltage waveform applied. (D) A calibration plot obtained by FSCAV post implantation (R2 = 0.996, slope = 0.0078 ± 0.0002 pC/nM (n = 7 electrodes), which when accounting for electrode area and equivalents transferred, corresponds to b = 0.0037 ± 0.0002 cm. Reproduced with permission from Atcherley et al.133
Atcherley et al. reported a tonic concentration of 90 ± 9 nM of DA in the nucleus accumbens core of an anesthetized mouse with a limit of detection of 3.4 ± 0.8 nM and a temporal resolution of 30s.134, 135 FSCAV was recently coupled to FSCV to concurrently measure both stimulated release and tonic DA in brain slices.135 In an alternate strategy, Oh et al. changed the waveform for FSCV into a “Mexican hat” waveform and introduced a dual-background subtraction protocol to measure tonic DA.136 They termed this new method charge balancing multiple waveform FSCV. In a follow up study, the group utilized multiple cyclic square wave voltammetry for measuring tonic DA, which, like FSCAV, also utilized a holding potential period to control DA adsorption onto the carbon fiber. In this method, they modeled the fast capacitive current decays using a simple exponential decay equation and subtracted it out from the raw signal.137
Other approaches used mathematics to address the issue of the large background current. Johnson and Wightman optimized an experimental protocol in order to simplify background current to those that can be mathematically explained and then used a convolution-based method to predict and remove the resistive-capacitive component of the CFM background current.138
Simultaneous Measures of Other Analytes with Dopamine
Waveform and enzyme modifications have enabled simultaneous detection of DA with other analytes. The typical DA FSCV waveform has a positive potential limit of +1.3 V.139 By scanning more positive than this (+1.4 V) Spanos et al. were able to capture an oxidation peak for H2O2 in addition to DA.140 The group found that H2O2 levels attenuated both phasic and tonic levels of DA in vivo in the rat dorsal striatum. The same group reported that holding the potential of the traditional DA at −0.2 V (instead of −0.4 V), allowed for simultaneous detection of glucose (via H2O2 generated from a layer of glucose oxidase on the CFM) and DA.141 They found that stimulated release of DA in vivo was followed by an increase in glucose to meet the increased energy demanded by the stimulation. The Cans group constructed an amperometric biosensor by immobilizing an ultra-thin layer of glucose oxidase onto a Au-nanoparticle-covered CFM that permitted the simultaneous monitoring of glucose and DA with millisecond temporal resolution for both analytes.142
Other surface modifications have enabled detection of other analytes with DA. Cincotto et al. modified glassy carbon electrodes with a hybrid material consisting of mesoporous silica nanoparticles, graphene, and silver nanoparticles for simultaneous electrocatalytic reduction measurements of DA and epinephrine.143 Stephen and colleagues modified glassy carbon electrodes with a poly(o-methoxyaniline)-gold nanocomposite, which reduced overpotentials and separated overlapping peaks for simultaneous folic acid and DA detection.144 Si et al. used pyrrole and o-phenylenediamine monomers to form molecularly imprinted polymers for simultaneous detection of DA, norepinephrine, and epinephrine using differential pulse voltammetry.145
Other notable multimodal technology include work done by Lee et al., who improved upon a previous generation of their multi-modal device, called WINCS (wireless instantaneous neurotransmitter concentration sensing), by making a multi-channel version called WINCS Harmoni.146 Figure 7 shows (A) a photograph of the WINCS Harmoni device, (B) schematic of the functional components, (C) the analog-to-digital converter, and (D) typical calibration curves from each of the four recording channels. The beauty of this device lies in four primary aspects: 1) the wireless component reduces instrumentation clutter, 2) the multi-channel allows for simultaneous FSCV DA recordings in up to four channels, 3) the design allows for concurrent recordings of both striatal DA and 5-HT in the substantia nigra (SNr), and 4) a closed loop paradigm that gives the user the ability to adjust deep brain stimulation parameters based on real-time monitoring of neurotransmitter release in vivo. The authors successfully demonstrated the versatility of this device in swine, rodent, and non-human primate models.147
Figure 7.
(A) Photograph of the WINCS Harmoni device; (B) Schematic diagram showing the functional components in WINCS Harmoni, including the neurochemical sensing and stimulation boards, charging components, Bluetooth transceiver, primary microcontroller, and control software in the base station; (C) Image and dimensions of the WINCS Harmoni delta sigma (ΔΣ) analog-to-digital converter (ADC) that enables four channels of simultaneous neurochemical recordings; (D) Typical calibration curves for each of the four neurochemical recording channels in WINCS Harmoni showing a linear relationship between DA oxidation current and DA concentration. Reproduced with permission from Lee et al.148
Dopamine Measurements Integrated with Electrophysiology
An integrated measurement platform known as DANA (DA and Neural activity) was developed by Parent et al. to obtain near simultaneous electrophysiological and DA FSCV measurements.149 Single-unit and DA measurements were collected in awake and freely moving rats to demonstrate the potential of DANA to connect behavior to physiology and neurochemistry.149 Work from the Kassegne group created a DA and neural activity platform using four-channel glassy carbon flexible electrode array in four distinct brain regions.150
Spreading depolarization (SD) is a pathological process characterized by propagating waves of cell firing. SD waves can be diagnostic events for cell death in penumbral tissues but because of the non-specific firing associated with SD waves, multi-modal analyses are necessary for investigation of the phenomenon. Hobbs et al. created an integrated multimodal device that monitors oxygen levels (an indicator of cerebral blood flow and energy consumption) concurrently with DA and single unit recordings.151 The benefit of this microdevice is that it eliminated the need for multiple sensors, which are cumbersome but also cause significantly tissue damage. The group observed significant oxygen and DA fluctuations during spreading depolarization events.
Other notable publications include a multi-functional microelectrode array that contained nearly 60,000 electrodes and over 2000 electrophysiology channels for stimulation, FSCV, and impedance measurements in rat cortical neurons and cerebellar slices.152
Serotonin (5-HT)
Introduction
5-HT is a neuromodulator with a complex receptor profile. On the postsynaptic cell, 5-HT receptors include 2 inhibitory and 11 excitatory G protein-coupled receptors (GCPRs), and a ligand-gated ion channel (5-HT3). 5-HT signals are terminated via multiple mechanisms:
reuptake into presynaptic neuron and glia by 5-HT transporters (SERTs), known as Uptake 1
reuptake into other neuron types by monoamine transporters (DATs, norepinephrine transporters (NETs) or organic cation transporters (OCTs)), known as Uptake 2
presynaptic autoreceptor binding
5-HT is electroactive like DA, however, it has been greatly challenging to apply the tools successful for DA analysis to 5-HT measurements. For many decades, electrochemical 5-HT measurements were limited to ex vivo preparations such as cerebral spinal fluid155 or tissue slice preparations.156 Direct 5-HT detection in vivo was not achieved as early as DA detection because 5-HT oxidation products rapidly polymerize and foul the electrode surface. In 1995, Jackson et. al. set the groundwork for detecting exogenous 5-HT in vivo using FSCV with a novel waveform (+0.2 to +1.0 to −0.1 to +0.2 V, 1000 Vs−1), that dramatically decreased electrode fouling.157 They utilized this waveform in a ‘mock’ in vivo experiment, modeled after an experiment performed by Stamford et al., where dopaminergic neurons were induced to release 5-HT via inhibition of DA synthesis and preloading with 5-hydroxytryptaphan (5-HTP), the 5-HT precursor.158 In 2009, Hashemi et al. were the first to describe endogenous 5-HT measurements in mammalian models.139 They described the primary difficulty of in vivo measurements as 5-HT’s highly concentrated, electroactive metabolite, 5-hydroxyindoleacetic acid (5-HIAA) (not present in tissue slice preparations). Using a combination of the Jackson waveform and electrodeposition of Nafion™, they were able to measure 5-HT in vivo in the rat SNr.139 The following section details recent keynote studies utilizing 5-HT FSCV in physiological investigations.
Serotonin’s Role in Affective Disorders
Diagnosis of affective (mood) disorders would greatly benefit from electrochemical 5-HT detection. 5-HT is thought to modulate mood; it has long been postulated that 5-HT deficiency underlies the behavioral phenotypes of affective disorders such as depression.159 However, this hypothesis (the monoamine theory of depression) has been difficult to verify because of the challenge of measuring 5-HT in vivo on neurotransmission timescales. Using FSCV it is now possible to measure 5-HT with high temporal and spatial resolution in vivo. This has strengthened our knowledge of 5-HT physiology and pharmacology, as reviewed below, and will ultimately enable characterization of 5-HT in affective disease models.
In 2014, Wood et al. found that 5-HT in the mouse SNr had three uptake profiles: slow (>20 seconds), fast (<10 seconds), and hybrid (a combination of the slow and fast), with the hybrid mechanism being the most common of the uptake profile encountered in vivo.160 The ‘fast’ and ‘slow’ responses were identified as two distinct clearance mechanisms: Uptake 1 (slow), mediated by the SERTs, and Uptake 2 (fast), mediated by other monoamine transporters (DATs, NETs, and OCTs). This study also found that the electrical stimulation created autoreceptor inhibition of 5-HT that lasted 10s of seconds.160 West et. al. observed a “double peak” phenomenon in the mouse medial prefrontal cortex (mPFC) (Figure 8),161 in which two 5-HT events were released upon electrical stimulation of the medial forebrain bundle (MFB). This is in contrast to the one evoked peak typically seen in other brain regions.160, 162 Consistently, layers 1–3 of the mPFC produced a single evoked peak, whereas layers 5 and 6 produced a double peak.161 The authors hypothesized two types 5-HT input to the terminal, linked to discrete reuptake domains. An example of the double peak and the discrete reuptake domains are shown in Figure 8.
Figure 8.
Schematic showing how each peak in the current vs. time trace corresponds to different uptake mechanisms. Reproduced with permission from West, A., et al.161
Extracellular 5-HT is thought to be lower during depression,163 therefore selective 5-HT reuptake inhibitors (SSRIs), which inhibit the SERTs (presumably increasing extracellular 5-HT levels) are a common treatment. Wood and Hashemi administered acute doses of a common SSRI, escitalopram, to mice. The group found that the effects of this drug on 5-HT were dynamic, not reaching a steady state before drug metabolism.164 This study suggested that dose response curves should be redesigned. The Wightman group investigated the effects of SSRIs on autoreceptor-mediated inhibitory feedback and showed involvement of multiple modulatory mechanisms in response to the SSRI.165 These studies clearly show that SSRI effects on the 5-HT system are complex and in need of further study.
While in vivo 5-HT FSCV studies are ongoing recent technical advancements including spatial improvements, simultaneous detection of analytes and ambient 5-HT measurements are enriching the chemical toolbox with which 5-HT can be studied.
Novel Technical Advancements for Serotonin Measurements
Serotonin Measurements on a Nano Level
In vivo, CFMs are thought to measure from hundreds of synapses.166 CFMs are too large to probe events ex vivo from single synapses. As discussed above for ACh, the Shen lab’s nanopipet-based liquid-liquid interface probes are 7–35 nm in radius and can thus probe single synapses.81 For 5-HT detection, the nanopipettes were filled with an organic phase, 1,2-dichloroethane.81 Upon the application of a potential, 5-HT was transferred across the ITIES tip into the organic phase. The authors observed that a higher overpotential was required for transferring 5-HT across the interface compared to tryptamine and 5-HT so the detection of lower concentrations of 5-HT proved to be more difficult. Nonetheless, the authors achieved a limit of detection of 77 μM with a 21 nm pipette, which is likely sufficient for synaptic measurements.
Simultaneously Measuring Serotonin with Other Analytes
An important recent finding is 5-HT’s co-modulatory relationship with HA. The axons of these two modulatory systems are highly localized,167, 168 and prior ex vivo chemical measurements implied co-modulation.169–171 HA measurements are challenging, since HA electrooxidation is not straightforward and likely involves charge transfer.172 Samarnayake et al. optimized a waveform that enabled a robust, Faradaic oxidation peak in response to HA with an LOD of 1 μM and linear dynamic range spanned up to 20 μM. This was sufficient for measuring HA in vivo.172 Further experiments used this waveform to understand the modulation of 5-HT and HA in vivo. The group showed that 5-HT was inhibited by H3 heteroreceptors on post synaptic neurons.172 Figure 9 shows that 5-HT release is inhibited by HA even under varying factors including the stimulation frequency (9C), the stimulation pulse width (9D) and the stimulation amplitude (9E).
Figure 9.
(A) Representative color plot of the stimulated release of HA and 5-HT inhibition in the premammillary nucleus. (B) Correlation plot between [HA] and [5-HT] for all stimulation parameters. (C) Averaged current versus time traces along the two horizontal dashed lines of HA and 5-HT with respect to different stimulation frequencies (n = 5). (D) Averaged current responses to various stimulation pulse widths of HA and 5-HT (n = 5). (E) Averaged current responses to various stimulation amplitudes of HA and 5-HT (n = 5). HA, HA; 5-HT, 5-HT. Reproduced from Samaranayake et al. with permission.172
Other notable studies include the WINCS Harmoni wireless device created by Lee et al.148 that simultaneously detects 5-HT in the SNr and DA in the striatum. More details on WINCS Harmoni can be found in the DA section of this review (vide supra). The Dayan lab created a mathematical algorithm capable of separating DA and 5-HT signals in humans.173 Finally, the Cai and Liu labs are working on electrochemical arrays with the capability of measuring 5-HT with other analyte and the potential for future in vivo analysis.174, 175
Ambient, Steady-State Serotonin Measurements
As described above, FSCV is background subtracted, thus basal or ambient, steady state 5-HT values cannot be garnered with this method. Abdalla et al. optimized FSCAV for 5-HT measurements and reported basal levels of 5-HT in the CA2 region of the hippocampus as 64.9 ± 2.3 nM in vivo.162 The technique shows linearity up to 600 nM with an LOD of 1.5 nM. Instrumentation for FSCAV has recently been simplified such that it can be constructed by non-experts with with simple electrical components.176
Other Neurochemicals
As the community develops better tools for defining the roles of neurotransmitters in disease, we can better focus diagnostic tests on neurotransmitters specific to distinct disorders. GABA is the most abundant inhibitory neurotransmitter.177 Because GABA is not easily redox active, electrochemical analysis of this neurotransmitter is challenging.178 The Shen lab applied their nanopipette approach to GABA.179 Unlike the analytes reviewed here, GABA is a zwitterion at neutral pH; this phenomenon makes it very difficult make GABA partition between phases. To facilitate partitioning between phases, octanoic acid was added to lower the pH along with dibenzo-18-crown-6, thus detection of protonated GABA.179 The Arumugam lab took an interesting electrochemical approach to detecting GABA simultaneously with Glu using a microarray with GABA and Glu biosensors. On site 1 of the array is a Glu biosensor and on site 2 is a GABA biosensor side-by-side with a second Glu biosensor. The group measured the current generated from H2O2 oxidation at both electrodes. The current at site 1 was due to Glu only. The current at site 2 was due to Glu and GABA, therefore subtraction of site 1 current from site 2 allowed GABA quantification.180
Peptides are strings of amino acids that act as signaling molecules in the brain. The Sombers lab created a sawhorse FSCV waveform to detect Met-enkephalins. The detection scheme is shown in Figure 10. The sawhorse FSCV waveform (Figure 10B) is modified from the conventional one used for DA detection (Figure 10A). Using the conventional waveform produced significant electrode fouling (Figure 10C, asterisk), which was not observed in the color plot for modified sawhorse waveform. Their method has high selectivity, being able to distinguish Leu- and Met-enkephalin, which differ by a single amino acid.181 The group successfully measured norepinephrine and Met-enkephalin release after mild electrical stimulation in adrenal tissue slice.
Figure 10.
(A) Triangular waveform. (B) Modified sawhorse waveform (MSW). (C, D) Representative in vitro voltammetric data collected using the waveforms depicted in parts A and B, respectively, where the ordinate is the potential applied to the carbon-fiber electrode, the abscissa is time in seconds, and the current (nA) is depicted in false color.55 2 μM M-ENK was introduced to the microelectrode at the time indicated by the red bar. Displayed voltammograms were extracted at the time indicated by the dashed line. Asterisks indicate electrode fouling. Reproduced with permission from Schmidt et al.181
The Venton group has been successful at measuring a variety of neurotransmitters including octopamine and adenosine.182–184 Octopamine is a biogenic amine in invertebrates that regulates intracellular cyclic AMP (adenosine monophosphate) and Ca2+.185 Pyakurel et al. first measured octopamine using FSCV in the ventral nerve cord of Drosophilia melanogaster larvae.182 Octopamine was released via optogenetic red light-stimulated release with a total simulation time of 1 s or less.182 Adenosine is a nucleoside produced from the breakdown of ATP. In the central nervous system, this molecule plays an important role in many biological processes, such as regulating neurotransmission and reducing excitotoxicity.183 Nguyen and Venton developed a method for direct adenosine detection using FSCV.183 Spontaneous adenosine transients were observed in addition to electrically and mechanically stimulated release.183 In vivo clearance of spontaneous adenosine was shown to occur through multiple mechanisms in the rat caudate putamen.184 These mechanisms include reuptake through the equilibrative nucleoside transport 1, as well as metabolism of adenosine by adenosine deaminase and adenosine kinase.184 Ganesana et al. examined spontaneous adenosine transients during cerebral ischemia.186 They found a 52% increase in the number of adenosine transients and a 53% increase in cumulative adenosine concentration during the early stages of cerebral ischemia as compared to normoxia control rats.186 Another group that studied adenosine developed synthetic boron-doped diamond-based electrodes for chronic in vivo measurements of adenosine in humans undergoing deep brain stimulation187 surgeries for tremor treatment. These diamond-based electrodes, showing little to no degradation even after 5.2 million cycles of FSCV experiments (144 hrs at 10 Hz), are two-orders of magnitude more robust than carbon fiber-based electrodes.187
Melatonin is a hormone produced by the pineal gland and lymph nodes188 and is thought to play a role in regulating circadian rhythm.189 The Ross lab developed a new waveform to selectively detect melatonin and to reduce fouling otherwise observed with conventional waveforms.190 The authors successfully used this new waveform for melatonin detection in lymph node tissue slice preparations.190 In a similar approach, the same group developed a novel waveform for detection of the neuromodulator guanosine.191 Their optimized approach was selective for guanosine over adenosine because two oxidation events were observed for guanosine at +0.8 V and +1.3 V. This method was successfully applied to measuring exogenously applied guanosine in tissue slice preparations.191
Conclusion and Future Direction
Neurochemical diagnosis for brain disorders is not available due to a lack of in vivo sensors capable of monitoring neurotransmitters and neuromodulators. This review highlighted advancements made in the field of electrochemical microdevices over the past five years for detection and quantification of neurochemical biomarkers of brain disorders. The potential for these analytes to act as biomarkers was discussed and novel measurement methods were highlighted. Specifically, we began each neurotransmitter section with a discussion of what we have learned thus far about the role of each of them in various applicable brain physiology using existing and emerging electrochemical techniques. We then focused on emerging biosensor technology for Glu and 5-HT detection and voltammetric methods for DA and 5-HT measurements. We ended the review with discussion about other neuromodulators of interest, e.g. peptides, adenosine, etc., and what tools were designed to measure them.
Via this review we highlighted the considerable progress made thus far in the field of electrochemical sensing for in vivo neurotransmitters. However, there are still challenges that need to be addressed when moving towards diagnostic devices. First, probe size remains problematic. Implantation is a physical perturbation to brain tissue. Ongoing efforts to make probe sizes comparable to interneuron distances will minimize damage and reduce inflammation. Furthermore, ongoing miniaturization to nanometer scales will allow synaptic measurements. Second, electrochemical sensing is limited to a few electroactive species. Peptides and proteins still evade detection via electrochemical sensors and thus cannot be measured with the same spatiotemporal resolution as smaller, more classical neuromodulators. Future horizons for this type of work may include aptamer modifications to electrodes. Lastly, and perhaps the most significant, there exist no clinical measurements in humans but we are confident, due to the rapid progress in the field reviewed here, that such measurements will be facilitated in the near future.
Structure 1.
Glu Molecule
Structure 2.
ACh Molecule
Structure 3.
DA Molecule
Structure 4.
5-HT Molecule
Acknowledgements
The authors would like to thank Jordan Holmes for making the neurotransmitter molecules and both Jordan Holmes and Shane Berger for their contributions to the TOC image. The National Institutes of Health (R01 MH106563 for P.H.) funded this work.
List of Abbreviations
- Glu
glutamate
- DA
dopamine
- Ach
acetylcholine
- 5-HT
serotonin
- HA
histamine
- GABA
gamma-aminobutyric acid
- DNA
deoxyribonucleic acid
- NDMA
N-methyl-D-aspartate
- AMPA
α-amino-3-hydroxy-5-methyl-4-isoxazole-propionic acid
- PFC
prefrontal cortex
- mPFC
medial prefrontal cortex
- AA
ascorbic acid
- ITIES
interface between two immiscible electrolyte solutions
- CFMs
carbon fiber microelectrodes
- FSCV
fast scan cyclic voltammetry
- FSCAV
fast scan controlled adsorption voltammetry
- WINCS
wireless instantaneous neurotransmitter concentration sensing
- SNr
substantia nigra pars reticulata
- DANA
dopamine and neural activity
- SD
spreading depolarization
- 5-HTP
5-hydroxytryptaphan
- 5-HIAA
5-hydroxyindoleacetic acid
- SERTs
selective serotonin reuptake inhibitors
- DATs
dopamine transporters
- NETs
norepinephrine transporters
- OCTs
organic cation transporters
References
- 1.Oaklander M, Time Magazine, 2017, 190, 38–45. [Google Scholar]
- 2.Settle FA, Handbook of instrumental techniques for analytical chemistry, Prentice Hall PTR, Upper Saddle River, NJ, 1997. [Google Scholar]
- 3.Dankoski E and Wightman R, Frontiers in Integrative Neuroscience, 2013, 7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Jaquins-Gerstl A and Michael AC, Analyst, 2015, 140, 3696–3708. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Dzyadevych SV, Arkhypova VN, Soldatkin AP, El’skaya AV, Martelet C and Jaffrezic-Renault N, IRBM, 2008, 29, 171–180. [DOI] [PubMed] [Google Scholar]
- 6.Kozai TDY, Jaquins-Gerstl AS, Vazquez AL, Michael AC and Cui XT, ACS Chemical Neuroscience, 2015, 6, 48–67. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Putzbach W and Ronkainen JN, Sensors, 2013, 13. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Javitt DC, Molecular psychiatry, 2004, 9, 984. [DOI] [PubMed] [Google Scholar]
- 9.Meldrum BS, The Journal of nutrition, 2000, 130, 1007S–1015S. [DOI] [PubMed] [Google Scholar]
- 10.Benarroch EE, Neurology, 2010, 74, 259. [DOI] [PubMed] [Google Scholar]
- 11.Zhou Y and Danbolt NC, Journal of Neural Transmission, 2014, 121, 799–817. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Kusakabe H, Midorikawa Y, Fujishima T, Kuninaka A and Yoshino H, Agricultural and biological chemistry, 1983, 47, 1323–1328. [Google Scholar]
- 13.Kulagina NV, Shankar L and Michael AC, Analytical Chemistry, 1999, 71, 5093–5100. [DOI] [PubMed] [Google Scholar]
- 14.Hu J, Wisetsuwannaphum S and Foord JS, Faraday Discussions, 2014, 172, 457–472. [DOI] [PubMed] [Google Scholar]
- 15.Frey O, Holtzman T, McNamara RM, Theobald DEH, van der Wal PD, de Rooij NF, Dalley JW and Koudelka-Hep M, Biosensors and Bioelectronics, 2010, 26, 477–484. [DOI] [PubMed] [Google Scholar]
- 16.Weltin A, Kieninger J and Urban GA, Analytical and bioanalytical chemistry, 2016, 408, 4503–4521. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Vasylieva N, Maucler C, Meiller A, Viscogliosi H, Lieutaud T, Barbier D and Marinesco S, Analytical Chemistry, 2013, 85, 2507–2515. [DOI] [PubMed] [Google Scholar]
- 18.Scouten WH, Luong JHT and Stephen Brown R, Trends in Biotechnology, 1995, 13, 178–185. [Google Scholar]
- 19.Freire RS, Pessoa CA, Mello LD and Kubota LT, Journal of the Brazilian Chemical Society, 2003, 14, 230–243. [Google Scholar]
- 20.Putzbach W and Ronkainen NJ, Sensors (Basel, Switzerland), 2013, 13, 4811–4840. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Hughes G, Pemberton RM, Fielden PR and Hart JP, TrAC Trends in Analytical Chemistry, 2016, 79, 106–113. [Google Scholar]
- 22.Bidan G, Sensors and Actuators B: Chemical, 1992, 6, 45–56. [Google Scholar]
- 23.Bartlett PN and Cooper JM, Journal of Electroanalytical Chemistry, 1993, 362, 1–12. [Google Scholar]
- 24.Palmisano F, Centonze D, Guerrieri A and Zambonin PG, Biosensors and Bioelectronics, 1993, 8, 393–399. [Google Scholar]
- 25.Emr SA and Yacynych AM, Electroanalysis, 1995, 7, 913–923. [Google Scholar]
- 26.Trojanowicz M and vel Krawczyk TK, Microchimica Acta, 1995, 121, 167–181. [Google Scholar]
- 27.Wahono N, Qin S, Oomen P, Cremers TIF, de Vries MG and Westerink BHC, Biosensors and Bioelectronics, 2012, 33, 260–266. [DOI] [PubMed] [Google Scholar]
- 28.Witkowski A and Brajter-Toth A, Analytical chemistry, 1992, 64, 635–641. [DOI] [PubMed] [Google Scholar]
- 29.Hamdi N, Wang J, Walker E, Maidment NT and Monbouquette HG, Journal of Electroanalytical Chemistry, 2006, 591, 33–40. [Google Scholar]
- 30.Hamdi N, Wang J and Monbouquette HG, Journal of Electroanalytical Chemistry, 2005, 581, 258–264. [Google Scholar]
- 31.Morales-Villagrán A, Medina-Ceja L and López-Pérez SJ, Journal of Neuroscience Methods, 2008, 168, 48–53. [DOI] [PubMed] [Google Scholar]
- 32.Wassum KM, Tolosa VM, Wang J, Walker E, Monbouquette HG and Maidment NT, Sensors, 2008, 8, 5023–5036. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Wassum KM, Tolosa VM, Tseng TC, Balleine BW, Monbouquette HG and Maidment NT, The Journal of Neuroscience, 2012, 32, 2734. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Tolosa VM, Wassum KM, Maidment NT and Monbouquette HG, Biosensors and Bioelectronics, 2013, 42, 256–260. [DOI] [PubMed] [Google Scholar]
- 35.Burmeister JJ and Gerhardt GA, Analytical chemistry, 2001, 73, 1037–1042. [DOI] [PubMed] [Google Scholar]
- 36.McLamore ES, Mohanty S, Shi J, Claussen J, Jedlicka SS, Rickus JL and Porterfield DM, Journal of Neuroscience Methods, 2010, 189, 14–22. [DOI] [PubMed] [Google Scholar]
- 37.Boo H, Jeong R-A, Park S, Kim KS, An KH, Lee YH, Han JH, Kim HC and Chung TD, Analytical Chemistry, 2006, 78, 617–620. [DOI] [PubMed] [Google Scholar]
- 38.Gholizadeh A, Shahrokhian S, Iraji zad A, Mohajerzadeh S, Vosoughi M, Darbari S and Sanaee Z, Biosensors and Bioelectronics, 2012, 31, 110–115. [DOI] [PubMed] [Google Scholar]
- 39.Gholizadeh A, Shahrokhian S, Iraji zad A, Mohajerzadeh S, Vosoughi M, Darbari S, Koohsorkhi J and Mehran M, Analytical Chemistry, 2012, 84, 5932–5938. [DOI] [PubMed] [Google Scholar]
- 40.Dey RS, Bera RK and Raj CR, Analytical and Bioanalytical Chemistry, 2013, 405, 3431–3448. [DOI] [PubMed] [Google Scholar]
- 41.Ricci F and Palleschi G, Biosensors and Bioelectronics, 2005, 21, 389–407. [DOI] [PubMed] [Google Scholar]
- 42.Ricci F, Amine A, Moscone D and Palleschi G, Biosensors and Bioelectronics, 2007, 22, 854–862. [DOI] [PubMed] [Google Scholar]
- 43.Qin S, Van der Zeyden M, Oldenziel HW, Cremers IT and Westerink HB, Sensors, 2008, 8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44.Hamdan SK and Mohd Zain A, The Malaysian journal of medical sciences : MJMS, 2014, 21, 12–26. [PMC free article] [PubMed] [Google Scholar]
- 45.Naylor E, Aillon DV, Gabbert S, Harmon H, Johnson DA, Wilson GS and Petillo PA, Journal of electroanalytical chemistry (Lausanne, Switzerland), 2011, 656, 106–113. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46.Johnston MV, Ammanuel S, O’Driscoll C, Wozniak A, Naidu S and Kadam SD, Frontiers in systems neuroscience, 2014, 8, 118–118. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 47.Lenoir M and Kiyatkin EA, Journal of neurochemistry, 2013, 127, 541–551. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 48.Wakabayashi KT and Kiyatkin EA, Journal of neurophysiology, 2012, 108, 285–299. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Rahman MA, Kwon N-H, Won M-S, Choe ES and Shim Y-B, Analytical Chemistry, 2005, 77, 4854–4860. [DOI] [PubMed] [Google Scholar]
- 50.Malvaez M, Greenfield VY, Wang AS, Yorita AM, Feng L, Linker KE, Monbouquette HG and Wassum KM, Scientific Reports, 2015, 5, 12511. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 51.Scofield MD, Boger HA, Smith RJ, Li H, Haydon PG and Kalivas PW, Biological psychiatry, 2015, 78, 441–451. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52.Özel RE, Ispas C, Ganesana M, Leiter JC and Andreescu S, Biosensors and Bioelectronics, 2014, 52, 397–402. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 53.Shi W, Lin N, Song Y, Liu C, Zhou S and Cai X, Biosensors and Bioelectronics, 2014, 51, 244–248. [DOI] [PubMed] [Google Scholar]
- 54.Tseng TT, Chang C-F and Chan W-C, Molecules, 2014, 19. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 55.Weltin A, Kieninger J, Enderle B, Gellner A-K, Fritsch B and Urban GA, Biosensors and Bioelectronics, 2014, 61, 192–199. [DOI] [PubMed] [Google Scholar]
- 56.Weltin A, Enderle B, Kieninger J and Urban GA, IEEE Sensors Journal, 2014, 14, 3345–3351. [Google Scholar]
- 57.Clay M and Monbouquette HG, ACS Chemical Neuroscience, 2018, 9, 241–251. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 58.Sainio S, Palomäki T, Tujunen N, Protopopova V, Koehne J, Kordas K, Koskinen J, Meyyappan M and Laurila T, Molecular Neurobiology, 2015, 52, 859–866. [DOI] [PubMed] [Google Scholar]
- 59.Nasr B, Chatterton R, Yong JHM, Jamshidi P, D’Abaco GM, Bjorksten AR, Kavehei O, Chana G, Dottori M and Skafidas E, Biosensors, 2018, 8, 14. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 60.Jamal M, Chakrabarty S, Yousuf MA, Khosla A and Razeeb KM, Microsystem Technologies, 2018, 24, 4193–4206. [Google Scholar]
- 61.Yu H, Ma Z and Wu Z, Analytica Chimica Acta, 2015, 896, 137–142. [DOI] [PubMed] [Google Scholar]
- 62.Liang B, Zhang S, Lang Q, Song J, Han L and Liu A, Analytica Chimica Acta, 2015, 884, 83–89. [DOI] [PubMed] [Google Scholar]
- 63.Hughes G, Pemberton RM, Fielden PR and Hart JP, Sensors and Actuators B: Chemical, 2015, 216, 614–621. [Google Scholar]
- 64.Wu F, Yu P, Yang X, Han Z, Wang M and Mao L, Journal of the American Chemical Society, 2018, 140, 12700–12704. [DOI] [PubMed] [Google Scholar]
- 65.Moore KM, Himmler BT, Teplitzky BA, Johnson MD and Meisel RL, Journal of visualized experiments : JoVE, 2017, DOI: 10.3791/56135, 56135. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 66.Massicotte G, Carrara S, Di Micheli G and Sawan M, IEEE transactions on biomedical circuits and systems, 2016, 10, 731–741. [DOI] [PubMed] [Google Scholar]
- 67.Ferreira NR, Ledo A, Laranjinha J, Gerhardt GA and Barbosa RM, Bioelectrochemistry, 2018, 121, 142–150. [DOI] [PubMed] [Google Scholar]
- 68.Wei W, Song Y, Wang L, Zhang S, Luo J, Xu S and Cai X, Microsystems & Nanoengineering, 2015, 1, 15002. [Google Scholar]
- 69.Fan X, Song Y, Ma Y, Zhang S, Xiao G, Yang L, Xu H, Zhang D and Cai X, Sensors (Basel, Switzerland), 2016, 17, 61. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 70.Picciotto MR, Higley MJ and Mineur YS, Neuron, 2012, 76, 116–129. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 71.Garguilo MG and Michael AC, TrAC Trends in Analytical Chemistry, 1995, 14, 164–169. [Google Scholar]
- 72.Mitchell KM, Analytical Chemistry, 2004, 76, 1098–1106. [DOI] [PubMed] [Google Scholar]
- 73.Bruno JP, Gash C, Martin B, Zmarowski A, Pomerleau F, Burmeister J, Huettl P and Gerhardt GA, European Journal of Neuroscience, 2006, 24, 2749–2757. [DOI] [PubMed] [Google Scholar]
- 74.Burmeister JJ, Pomerleau F, Huettl P, Gash CR, Werner CE, Bruno JP and Gerhardt GA, Biosensors and Bioelectronics, 2008, 23, 1382–1389. [DOI] [PubMed] [Google Scholar]
- 75.Parikh V, Pomerleau F, Huettl P, Gerhardt GA, Sarter M and Bruno JP, European Journal of Neuroscience, 2004, 20, 1545–1554. [DOI] [PubMed] [Google Scholar]
- 76.Burmeister JJ, Palmer M and Gerhardt GA, Analytica chimica acta, 2003, 481, 65–74. [Google Scholar]
- 77.Howe WM, Berry AS, Francois J, Gilmour G, Carp JM, Tricklebank M, Lustig C and Sarter M, The Journal of Neuroscience, 2013, 33, 8742. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 78.Gritton HJ, Howe WM, Mallory CS, Hetrick VL, Berke JD and Sarter M, Proceedings of the National Academy of Sciences of the United States of America, 2016, 113, E1089–E1097. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 79.Howe WM, Gritton HJ, Lusk NA, Roberts EA, Hetrick VL, Berke JD and Sarter M, The Journal of neuroscience : the official journal of the Society for Neuroscience, 2017, 37, 3215–3230. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 80.Teles-Grilo Ruivo LM, Baker KL, Conway MW, Kinsley PJ, Gilmour G, Phillips KG, Isaac JTR, Lowry JP and Mellor JR, Cell reports, 2017, 18, 905–917. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 81.Colombo ML, Sweedler JV and Shen M, Analytical Chemistry, 2015, 87, 5095–5100. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 82.Welle TM, Alanis K, Colombo ML, Sweedler JV and Shen M, Chemical Science, 2018, 9, 4937–4941. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 83.Shen M, Qu Z, DesLaurier JT, Welle TM, Sweedler JV and Chen R, Journal of the American Chemical Society, 2018. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 84.Baker KL, Bolger FB and Lowry JP, Analyst, 2015, 140, 3738–3745. [DOI] [PubMed] [Google Scholar]
- 85.Kanik FE, Kolb M, Timur S, Bahadir M and Toppare L, International Journal of Biological Macromolecules, 2013, 59, 111–118. [DOI] [PubMed] [Google Scholar]
- 86.Cai J-R, Zhou L-N and Han E, Analytical Sciences, 2014, 30, 669–673. [DOI] [PubMed] [Google Scholar]
- 87.Itoh T, Shimomura T, Hayashi A, Yamaguchi A, Teramae N, Ono M, Tsunoda T, Mizukami F, Stucky GD and Hanaoka T.-a., Analyst, 2014, 139, 4654–4660. [DOI] [PubMed] [Google Scholar]
- 88.Chauhan N, Narang J and Jain U, Analyst, 2015, 140, 1988–1994. [DOI] [PubMed] [Google Scholar]
- 89.Santos RM, Laranjinha J, Barbosa RM and Sirota A, Biosensors and Bioelectronics, 2015, 69, 83–94. [DOI] [PubMed] [Google Scholar]
- 90.Mousavi MPS, Abd El-Rahman MK, Mahmoud AM, Abdelsalam RM and Bühlmann P, ACS Sensors, 2018, DOI: 10.1021/acssensors.8b00950. [DOI] [PubMed] [Google Scholar]
- 91.Keighron JD, Wigström J, Kurczy ME, Bergman J, Wang Y and Cans A-S, ACS Chemical Neuroscience, 2015, 6, 181–188. [DOI] [PubMed] [Google Scholar]
- 92.Zhang Y, Arugula MA, Kirsch JS, Yang X, Olsen E and Simonian AL, Langmuir, 2015, 31, 1462–1468. [DOI] [PubMed] [Google Scholar]
- 93.Monti P, Calia G, Marceddu S, Dettori MA, Fabbri D, Jaoua S, O’Neill RD, Migheli Q, Delogu G and Serra PA, Talanta, 2017, 162, 151–158. [DOI] [PubMed] [Google Scholar]
- 94.Chauhan N and Pundir CS, Biosensors and Bioelectronics, 2014, 61, 1–8. [DOI] [PubMed] [Google Scholar]
- 95.Chauhan N, Chawla S, Pundir CS and Jain U, Biosensors and Bioelectronics, 2017, 89, 377–383. [DOI] [PubMed] [Google Scholar]
- 96.Sulzer D, Cragg SJ and Rice ME, Basal ganglia, 2016, 6, 123–148. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 97.Ewing AG, Wightman RM and Dayton MA, Brain Research, 1982, 249, 361–370. [DOI] [PubMed] [Google Scholar]
- 98.Wightman RM, May LJ and Michael AC, Analytical chemistry, 1988, 60, 769A–793A. [DOI] [PubMed] [Google Scholar]
- 99.Heien MLAV, Phillips PEM, Stuber GD, Seipel AT and Wightman RM, Analyst, 2003, 128, 1413–1419. [DOI] [PubMed] [Google Scholar]
- 100.Takmakov P, Zachek MK, Keithley RB, Walsh PL, Donley C, McCarty GS and Wightman RM, Analytical Chemistry, 2010, 82, 2020–2028. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 101.Schenk JO, Miller E, Rice ME and Adams RN, Brain research, 1983, 277, 1–8. [DOI] [PubMed] [Google Scholar]
- 102.Venton BJ and Wightman RM, Journal, 2003. [Google Scholar]
- 103.Kovach PM, Ewing AG, Wilson RL and Wightman RM, Journal of neuroscience methods, 1984, 10, 215–227. [DOI] [PubMed] [Google Scholar]
- 104.Howell JO, Kuhr WG, Ensman RE and Wightman RM, Journal of electroanalytical chemistry and interfacial electrochemistry, 1986, 209, 77–90. [Google Scholar]
- 105.Kuhr WG and Wightman RM, Brain Research, 1986, 381, 168–171. [DOI] [PubMed] [Google Scholar]
- 106.Rebec GV, Christensen JRC, Guerra C and Bardo MT, Brain research, 1997, 776, 61–67. [DOI] [PubMed] [Google Scholar]
- 107.Phillips PEM, Stuber GD, Heien MLAV, Wightman RM and Carelli RM, Nature, 2003, 422, 614. [DOI] [PubMed] [Google Scholar]
- 108.Owesson-White CA, Cheer JF, Beyene M, Carelli RM and Wightman RM, Proceedings of the National Academy of Sciences, 2008, 105, 11957. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 109.Flagel SB, Clark JJ, Robinson TE, Mayo L, Czuj A, Willuhn I, Akers CA, Clinton SM, Phillips PEM and Akil H, Nature, 2010, 469, 53. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 110.Howe MW, Tierney PL, Sandberg SG, Phillips PEM and Graybiel AM, Nature, 2013, 500, 575. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 111.Cameron CM, Wightman RM and Carelli RM, Neuropharmacology, 2016, 111, 223–230. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 112.Radke AK, Kocharian A, Covey DP, Lovinger DM, Cheer JF, Mateo Y and Holmes A, European Journal of Neuroscience, 2018, 0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 113.Pultorak KJ, Schelp SA, Isaacs DP, Krzystyniak G and Oleson EB, eNeuro, 2018, 5, ENEURO.0058–0018.2018. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 114.Wenzel JM, Oleson EB, Gove WN, Cole AB, Gyawali U, Dantrassy HM, Bluett RJ, Dryanovski DI, Stuber GD and Deisseroth K, Current Biology, 2018, 28, 1392–1404. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 115.Gentry RN, Schuweiler DR and Roesch MR, Brain Research, 2018, DOI: 10.1016/j.brainres.2018.10.008. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 116.Naef L, Seabrook L, Hsiao J, Li C and Borgland SL, European Journal of Neuroscience, 2018, 0. [DOI] [PubMed] [Google Scholar]
- 117.Calipari ES, Juarez B, Morel C, Walker DM, Cahill ME, Ribeiro E, Roman-Ortiz C, Ramakrishnan C, Deisseroth K, Han M-H and Nestler EJ, Nature Communications, 2017, 8, 13877. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 118.Graf EN, Wheeler RA, Baker DA, Ebben AL, Hill JE, McReynolds JR, Robble MA, Vranjkovic O, Wheeler DS, Mantsch JR and Gasser PJ, The Journal of Neuroscience, 2013, 33, 11800. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 119.Kishida KT, Saez I, Lohrenz T, Witcher MR, Laxton AW, Tatter SB, White JP, Ellis TL, Phillips PEM and Montague PR, Proceedings of the National Academy of Sciences, 2016, 113, 200. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 120.Shin M, Field TM, Stucky CS, Furgurson MN and Johnson MA, ACS chemical neuroscience, 2017, 8, 1880–1888. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 121.Kaplan SV, Limbocker RA, Gehringer RC, Divis JL, Osterhaus GL, Newby MD, Sofis MJ, Jarmolowicz DP, Newman BD and Mathews TA, ACS chemical neuroscience, 2016, 7, 689–699. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 122.Field TM, Shin M, Stucky CS, Loomis J and Johnson MA, ChemPhysChem, 2018, 19, 1192–1196. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 123.Feduccia AA, Simms JA, Mill D, Yi HY and Bartlett SE, British Journal of Pharmacology, 2014, 171, 3420–3431. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 124.Spanos M, Xie X, Gras-Najjar J, White SC and Sombers LA, ACS Chemical Neuroscience, 2018, DOI: 10.1021/acschemneuro.8b00492. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 125.Roberts JG, Toups JV, Eyualem E, McCarty GS and Sombers LA, Analytical Chemistry, 2013, 85, 11568–11575. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 126.Schuweiler DR, Howard CD, Ramsson ES and Garris PA, Analytical Chemistry, 2018, 90, 13434–13442. [DOI] [PubMed] [Google Scholar]
- 127.Meunier CJ, Roberts JG, McCarty GS and Sombers LA, ACS Chemical Neuroscience, 2017, 8, 411–419. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 128.Rodeberg NT, Sandberg SG, Johnson JA, Phillips PEM and Wightman RM, ACS Chemical Neuroscience, 2017, 8, 221–234. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 129.Nimbalkar S, Castagnola E, Balasubramani A, Scarpellini A, Samejima S, Khorasani A, Boissenin A, Thongpang S, Moritz C and Kassegne S, Scientific Reports, 2018, 8, 6958. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 130.Schwerdt HN, Kim M, Karasan E, Amemori S, Homma D, Shimazu H, Yoshida T, Langer R, Graybiel AM and Cima MJ. [DOI] [PMC free article] [PubMed]
- 131.Schwerdt HN, Shimazu H, Amemori K.-i., Amemori S, Tierney PL, Gibson DJ, Hong S, Yoshida T, Langer R and Cima MJ, Proceedings of the National Academy of Sciences, 2017, 201713756. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 132.Owesson‐White CA, Roitman MF, Sombers LA, Belle AM, Keithley RB, Peele JL, Carelli RM and Wightman RM, Journal of neurochemistry, 2012, 121, 252–262. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 133.Atcherley CW, Laude ND, Monroe EB, Wood KM, Hashemi P and Heien ML, ACS Chemical Neuroscience, 2015, 6, 1509–1516. [DOI] [PubMed] [Google Scholar]
- 134.Atcherley CW, Wood KM, Parent KL, Hashemi P and Heien ML, Chemical communications (Cambridge, England), 2015, 51, 2235–2238. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 135.Burrell MH, Atcherley CW, Heien ML and Lipski J, ACS Chemical Neuroscience, 2015, 6, 1802–1812. [DOI] [PubMed] [Google Scholar]
- 136.Oh Y, Park C, Kim DH, Shin H, Kang YM, DeWaele M, Lee J, Min H-K, Blaha CD, Bennet KE, Kim IY, Lee KH and Jang DP, Analytical Chemistry, 2016, 88, 10962–10970. [DOI] [PubMed] [Google Scholar]
- 137.Oh Y, Heien ML, Park C, Kang YM, Kim J, Boschen SL, Shin H, Cho HU, Blaha CD, Bennet KE, Lee HK, Jung SJ, Kim IY, Lee KH and Jang DP, Biosensors and Bioelectronics, 2018, 121, 174–182. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 138.Johnson JA and Wightman RM, The Electrochemical Society Interface, 2017, 26, 53–57. [Google Scholar]
- 139.Hashemi P, Dankoski EC, Petrovic J, Keithley RB and Wightman RM, Analytical Chemistry, 2009, 81, 9462–9471. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 140.Spanos M, Gras-Najjar J, Letchworth JM, Sanford AL, Toups JV and Sombers LA, ACS Chemical Neuroscience, 2013, 4, 782–789. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 141.Smith SK, Lee CA, Dausch ME, Horman BM, Patisaul HB, McCarty GS and Sombers LA, ACS Chemical Neuroscience, 2017, 8, 272–280. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 142.Bergman J, Mellander L, Wang Y and Cans A-S, Catalysts, 2018, 8, 34. [Google Scholar]
- 143.Cincotto FH, Canevari TC, Campos AM, Landers R and Machado SAS, Analyst, 2014, 139, 4634–4640. [DOI] [PubMed] [Google Scholar]
- 144.Sangamithirai D, Munusamy S, Narayanan V and Stephen A, Materials Science and Engineering: C, 2018, 91, 512–523. [DOI] [PubMed] [Google Scholar]
- 145.Si B and Song E, Microelectronic Engineering, 2018, 187–188, 58–65. [PMC free article] [PubMed] [Google Scholar]
- 146.Kimble CJ, Johnson DM, Winter BA, Whitlock SV, Kressin KR, Horne AE, Robinson JC, Bledsoe JM, Tye SJ, Chang S-Y, Agnesi F, Griessenauer CJ, Covey D, Shon Y-M, Bennet KE, Garris PA and Lee KH, Conference proceedings : … Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference, 2009, 2009, 4856–4859. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 147.Lee KH, Chang S-Y, Jang D-P, Kim I, Goerss S, Van Gompel J, Min P, Arora K, Marsh M, Hwang SC, Kimble CJ, Garris P, Blaha C and Bennet KE, Conference proceedings : … Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference, 2011, 2011, 677–680. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 148.Lee KH, Lujan JL, Trevathan JK, Ross EK, Bartoletta JJ, Park HO, Paek SB, Nicolai EN, Lee JH, Min H-K, Kimble CJ, Blaha CD and Bennet KE, Scientific Reports, 2017, 7, 46675. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 149.Parent KL, Hill DF, Crown LM, Wiegand J-P, Gies KF, Miller MA, Atcherley CW, Heien ML and Cowen SL, Analytical Chemistry, 2017, 89, 2790–2799. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 150.Castagnola E, Vahidi NW, Nimbalkar S, Rudraraju S, Thielk M, Zucchini E, Cea C, Carli S, Gentner TQ, Ricci D, Fadiga L and Kassegne S, MRS advances, 2018, 3, 1629–1634. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 151.Hobbs CN, Johnson JA, Verber MD and Wightman RM, Analyst, 2017, 142, 2912–2920. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 152.Dragas J, Viswam V, Shadmani A, Chen Y, Bounik R, Stettler A, Radivojevic M, Geissler S, Obien MEJ and Müller J, IEEE journal of solid-state circuits, 2017, 52, 1576–1590. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 153.Mohammad-Zadeh LF, Moses L and Gwaltney-Brant SM, Journal of Veterinary Pharmacology and Therapeutics, 2008, 31, 187–199. [DOI] [PubMed] [Google Scholar]
- 154.Berger M, Gray JA and Roth BL, Annual Review of Medicine, 2009, 60, 355–366. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 155.Huggins KN, Mathews TA, Locke JL, Szeliga KT, Friedman DP, Bennett AJ and Jones SR, Alcohol, 2012, 46, 371–376. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 156.John CE and Jones SR, 2007.
- 157.Jackson BP, Dietz SM and Wightman RM, Analytical Chemistry, 1995, 67, 1115–1120. [DOI] [PubMed] [Google Scholar]
- 158.Stamford JA, Kruk ZL, Millar J and Wightman RM, Neuroscience letters, 1984, 51, 133–138. [DOI] [PubMed] [Google Scholar]
- 159.Gonzalez O, Berry JT, Mcknight-Eily LR, Strine T, Edwards KW and Croft JB, Current Depression Among Adults - United States, 2006 and 2008, Center for Disease Control and Prevention, Hyattsville, MD, 2010. [Google Scholar]
- 160.Wood KM, Zeqja A, Nijhout HF, Reed MC, Best J and Hashemi P, Journal of Neurochemistry, 2014, 130, 351–359. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 161.West A, Best J, Abdalla A, Nijhout F, Reed M and Hashemi P, Neurochemistry International, 2018, DOI: 10.1016/j.neuint.2018.07.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 162.Abdalla A, Atcherley CW, Pathirathna P, Samaranayake S, Qiang B, Peña E, Morgan SL, Heien ML and Hashemi P, Analytical Chemistry, 2017, 89, 9703–9711. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 163.Anderson IM and Tomenson BM, Journal of Psychopharmacology, 1994, 8, 238–249. [DOI] [PubMed] [Google Scholar]
- 164.Wood KM and Hashemi P, ACS chemical neuroscience, 2013, 4, 715–720. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 165.Dankoski EC, Carroll S and Wightman RM, Journal of neurochemistry, 2016, 136, 1131–1141. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 166.Sames D, Dunn M, Karpowicz RJ Jr and Sulzer D, ACS chemical neuroscience, 2013, 4, 648–651. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 167.Brown RE, Stevens DR and Haas HL, Progress in Neurobiology, 2001, 63, 637–672. [DOI] [PubMed] [Google Scholar]
- 168.Haas HL, Sergeeva OA and Selbach O, Physiological Reviews, 2008, 88, 1183–1241. [DOI] [PubMed] [Google Scholar]
- 169.Pihel K, Hsieh S, Jorgenson JW and Wightman RM, Analytical chemistry, 1995, 67, 4514–4521. [DOI] [PubMed] [Google Scholar]
- 170.Threlfell S, Cragg SJ, Kalló I, Turi GF, Coen CW and Greenfield SA, Journal of Neuroscience, 2004, 24, 8704–8710. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 171.Threlfell S, Exley R, Cragg SJ and Greenfield SA, Journal of Neurochemistry, 2008, 107, 745–755. [DOI] [PubMed] [Google Scholar]
- 172.Samaranayake S, Abdalla A, Robke R, Nijhout HF, Reed MC, Best J and Hashemi P, Journal of Neurochemistry, 2016, 138, 374–383. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 173.Moran RJ, Kishida KT, Lohrenz T, Saez I, Laxton AW, Witcher MR, Tatter SB, Ellis TL, Phillips PEM and Dayan P, Neuropsychopharmacology, 2018, 43, 1425. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 174.Xu H, Wang L, Luo J, Song Y, Liu J, Zhang S and Cai X, Sensors (Basel, Switzerland), 2015, 15, 1008–1021. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 175.Khan MZH, Liu X, Tang Y, Zhu J, Hu W and Liu X, Microchimica Acta, 2018, 185, 439. [DOI] [PubMed] [Google Scholar]
- 176.Robke R, Hashemi P and Ramsson E, HardwareX, 2018, DOI: 10.1016/j.ohx.2018.e00051, e00051. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 177.Rowley HL, Martin KF and Marsden CA, Neuroscience, 1995, 68, 415–422. [DOI] [PubMed] [Google Scholar]
- 178.Reinhoud NJ, Brouwer H-J, van Heerwaarden LM and Korte-Bouws GAH, ACS chemical neuroscience, 2013, 4, 888–894. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 179.Iwai NT, Kramaric M, Crabbe D, Wei Y, Chen R and Shen M, Analytical chemistry, 2018, 90, 3067–3072. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 180.Hossain I, Tan C, Doughty PT, Dutta G, Murray TA, Siddiqui S, Iasemidis L and Arumugam PU, Frontiers in Neuroscience, 2018, 12, 500. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 181.Schmidt AC, Dunaway LE, Roberts JG, McCarty GS and Sombers LA, Analytical Chemistry, 2014, 86, 7806–7812. [DOI] [PubMed] [Google Scholar]
- 182.Pyakurel P, Privman Champaloux E and Venton BJ, ACS Chemical Neuroscience, 2016, 7, 1112–1119. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 183.Nguyen MD and Venton BJ, Computational and Structural Biotechnology Journal, 2015, 13, 47–54. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 184.Nguyen MD, Ross AE, Ryals M, Lee ST and Venton BJ, Pharmacology Research & Perspectives, 2015, 3, e00189. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 185.Balfanz S, Strünker T, Frings S and Baumann A, Journal of Neurochemistry, 2005, 94, 1168–1168. [DOI] [PubMed] [Google Scholar]
- 186.Ganesana M and Venton BJ, PloS one, 2018, 13, e0196932. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 187.Bennet KE, Tomshine JR, Min H-K, Manciu FS, Marsh MP, Paek SB, Settell ML, Nicolai EN, Blaha CD, Kouzani AZ, Chang S-Y and Lee KH, Frontiers in Human Neuroscience, 2016, 10, 102. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 188.Naji L, Carrillo-Vico A, Guerrero JM and Calvo JR, Life sciences, 2004, 74, 2227–2236. [DOI] [PubMed] [Google Scholar]
- 189.Reiter RJ, Experientia, 1993, 49, 654–664. [DOI] [PubMed] [Google Scholar]
- 190.Hensley AL, Colley AR and Ross AE, Analytical Chemistry, 2018, 90, 8642–8650. [DOI] [PubMed] [Google Scholar]
- 191.Cryan MT and Ross AE, Analyst, 2019, 144, 249–257. [DOI] [PubMed] [Google Scholar]