Abstract
Purpose
To capture the multiquantum coherence (MQC) 23Na signal. Different phase‐cycling options and sequences are compared in a unified theoretical layout, and a novel sequence is developed.
Methods
An open source simulation overview is provided with graphical explanations to facilitate MQC understanding and access to techniques. Biases such as B0 inhomogeneity and stimulated echo signal were simulated for 4 different phase‐cycling options previously described. Considerations for efficiency and accuracy lead to the implementation of a 2D Cartesian single and triple quantum imaging of sodium (CRISTINA) sequence employing two 6‐step cycles in combination with a multi‐echo readout. CRISTINA was compared to simultaneous single‐quantum and triple‐quantum‐filtered MRI of sodium (SISTINA) under strong static magnetic gradient. CRISTINA capabilities were assessed on 8 × 60 mL, 0% to 5% agarose phantom with 50 to 154 mM 23Na concentration at 7 T. CRISTINA was demonstrated subsequently in vivo in the brain.
Results
Simulation of B0 inhomogeneity showed severe signal dropout, which can lead to erroneous MQC measurement. Stimulated echo signal was highest at the time of triple‐quantum coherences signal maximum. However, stimulated echo signal is separated by Fourier Transform as an offset and did not interfere with MQC signals. The multi‐echo readout enabled capturing both single‐quantum coherences and triple‐quantum coherences signal evolution at once. Signal combination of 2 phase‐cycles with a corresponding B0 map was found to recover the signal optimally. Experimental results confirm and complement the simulations.
Conclusion
Considerations for efficient MQC measurements, most importantly avoiding B0 signal loss, led to the design of CRISTINA. CRISTINA captures triple‐quantum coherences and single‐quantum coherences signal evolution to provide complete sodium signal characterization including fast, slow, MQC amplitudes, and sodium concentration.
Keywords: 23Na MRI, coherence transfer, multiple‐quantum coherences, triple‐quantum sodium imaging
1. INTRODUCTION
Multiquantum sodium (23Na) NMR was first been investigated and described 3 decades ago. 1 , 2 , 3 , 4 , 5 Recently, technological advances have led to a revival of 23Na MRI, with a particular interest in the potential to link multiquantum 23Na MRI to underlying pathophysiological pathways. 6 , 7 , 8 , 9 In standard 23Na imaging experiments, detection of the single‐quantum (SQ) transition is performed directly after an excitation with similar approaches to conventional proton MRI. To exploit the potential of the spin 3/2 nuclei, multiquantum coherence (MQC) signals are built by coherence transfer and combined over multiple acquisitions using RF phase cycling. Eventually, 23Na triple‐quantum coherences (TQC) might provide additional information related to cell vitality compared to the single‐quantum coherences (SQC) signal alone. 10 A clear understanding of the mechanisms of MQC is necessary for relevant measurements and evading potential pitfalls. The description of MQC can be found in the clean form of the tensor formalism but spread in several papers 1 , 5 , 11 , 12 , 13 , 14 dating of 15 years at the least. These highly theoretical descriptions neither offer an intuitive way of understanding multiquantum mechanisms in the multidisciplinary field of MRI nor provide a basis to easily describe and relate the recent advances in triple‐quantum (TQ) 23Na NMR and MRI.
23Na spin 3/2 nuclei exhibit 4 possible energy levels. Depending on the surrounding medium, different transitions between the levels are possible. The electric quadrupole interaction determines the 23Na relaxation processes and fundamentally distinguishes it from the dominant dipole–dipole interaction of proton nuclei. Due to the quadrupolar nature of the sodium nuclei, higher quantum coherences can be measured when the correlation time (describing the fluctuations of the electric field gradient at the 23Na nuclei) 15 exceeds the Larmor period. The electric field gradient is generated by the electrons of the surrounding environment (ie, proteins, lipids, macromolecules). In biologic environment, there is a fluctuating quadrupolar interaction, which adds to the Zeeman splitting and leads to a biexponential relaxation behavior so that MQC signals in the form of double quantum coherence (DQC) and TQC can be observed (Figure 1A). 23Na MQC signal gives information about the interaction of the 23Na nuclei with its surrounding environment in vivo.
FIGURE 1.

A, 23Na spin 3/2 nuclei interaction with a magnetic field. In isotropic environment, the ground state splits into the 4 different energy levels with equidistant levels. In biologic environment, fluctuating quadrupolar interaction leads to the observation of DQC and TQC. Static quadrupolar interaction in ordered environments is rare in biological medium. B, The three pulses experiment used to achieve MQC transfer C, coherence transfer diagram for pathways that can be probed. Relaxation between the first and second pulse, τ 1, is crucial for TQC creation. The time between the second and third pulse (τ 2) is chosen as short as possible to limit MQC signal loss. The tensor Trank,order changes its order after each RF pulse, whereas only relaxation and quadrupolar coupling change the rank of the tensor. In perfect quadrature detection, only coherence level of −1 is observable. However, imperfect quadrature detection is common in MRI, and signals can end up in the +1 pathway as well. 23Na, sodium; DQC, double quantum coherence; MQC, multiquantum coherence; TQC, triple‐quantum coherences
In an anisotropic environment, the quadrupolar moment of the 23Na nuclei couples to the electric field gradient, which acts as relaxation mechanism leading to a more rapid decay of the outer than inner transitions of the spin 3/2 energy levels, resulting in a biexponential T2 relaxation with fast and slow components, which gives the possibility of MQC transfer due to violation of the coherence transfer rules. 1 , 4 , 16 In contrast, the quadrupole moment does not couple to an isotropic field; therefore, no MQC can be measured in isotropic medium (eg, saline solution).
A static quadrupolar interaction is observed in further macroscopically ordered environments, which is rare in biological medium but can be found in cartilage. DQC signal can yield information about the anisotropy in tissue because in ordered structures a preferred orientation of the quadrupolar 23Na nuclei relative to the magnetic field B0 exists. DQC arise from 2 mechanisms: biexponential relaxation (T32) and quadrupolar splitting (T22); for specific information about the anisotropy, a magic angle sequence selects the signal arising from T22. 4 , 17 , 18 In contrast, TQC signal arises only due to biexponential relaxation. Quadrupolar splitting within anisotropic structures has no additional effect. 11 , 12 Figure 1 shows the relevant processes. 16
To measure and filter for different coherence pathways, in general, a 3‐pulse sequence is needed along with RF phase cycling to select the coherence of interest. 2 In this paper, we want to give an intuitive and pictorial understanding of phase cycling‐based MQC buildup and the available choices in the corresponding 3‐pulse experiment. The purpose was to seek optimal efficiency of a 3‐pulse sequence, defined in this scope as the minimum number of cycles and steps per cycle to provide a complete and unbiased measurement of MQC 23Na signals. Thus, a time‐efficient sequence design is drawn from analytical and simulation results. This sequence is guaranteed to withstand B0 and stimulated echo (STE) biases and is optimal for clinical MQC imaging methods. Experimental results demonstrate the potential of proposed Cartesian imaging of single and triple‐quantum 23Na (CRISTINA).
2. THEORY
The pulse sequence is depicted along with the coherence pathway scheme in Figure 1. The conventional 3‐pulse experiment introduces 3 time constants as parameters that impact the eventual measured signal. Among these 3, τ 2 is usually minimized to neglect relaxation between the second and the third pulse; however, the evolution time, τ 1, and the TE are in strong relation with the biexponential relaxation that separates SQC from DQC and TQC. The sequence is repeated while cycling the phases of the RF pulses. The first pulse phase, ϕ 1, cycles through a defined phase cycle, whereas the second pulse is phase‐shifted by the “phaseshift, ξ” relative to the first pulse. The second pulse phase ϕ 2 will be given in relation to the first throughout the paper by its phase shift ξ = ϕ 2‐ϕ 1. The phase of the third pulse is set to 0°, as is the receiver phase. Exploiting the differences in evolution frequency between the MQC signals, an addition of the signals, leads to constructive and destructive interference of the MQC pathways depending on the selected phase cycling scheme. The multiple aspects of MQC measurements are covered in the following.
Different phase cycling options have been proposed to eliminate potential biases in MQC measurements. Four options have been highlighted, which are presented in summary in Table 1.
TABLE 1.
Overview over the highlighted phase‐cycle options
| Phase cycles | ∆ϕ 1 | ϕ 1, t = 0 | ξ = (ϕ 2‐ϕ 1) | Acronym | ||
|---|---|---|---|---|---|---|
| Option I | 1 × 6 steps | π/3 | One cycle | π/6 | π/2 | Original 1 |
| Option II | 2 × 8 steps | π/4 | First cycle | π/2 | π/2 | TQ(T)PPI 19 , 20 |
| Second cycle | π/2 | −π/2 | ||||
| Option III | 2 × 6 steps | π/3 | First cycle | π/2 | π/2 | Fleysher 26 |
| Second cycle | 0 | 0 | ||||
| Option IV | 4 × 6 steps | π/3 | In vivo cycles | π/6 | π/2 | SISTINA 22 |
| 7π/6 | −π/2 | |||||
| Phantom cycles | 2π/3 | 0 | ||||
| 5π/3 | 0 | |||||
| Option V | 2 × 6 steps | π/6 | First cycle | π/2 | π/2 | CRISTINA |
| Second cycle | 0 | 0 |
Abbreviations: CRISTINA, Cartesian imaging of single and triple‐quantum 23Na; SISTINA, simultaneous single‐quantum and triple‐quantum‐filtered MRI of 23Na; TQ(T)PPI, triple‐quantum (time) proportional phase increments.
First, the original 6 steps phase cycle, option I, which samples the coherence evolution over a 2π interval with a phase increment of π/3, a phase shift ξ = π/2, ϕ 1, t = 0 = π/6, and a constant phase for the third pulse and the receiver of 0°. 1 The phase increment of π/3 places the TQ frequency at the Nyquist limit.
Second, option II, the 2 × 8‐steps NMR method of triple‐quantum (time) proportional phase increments TQ(T)PPI. This NMR method was developed to circumvent the need to optimize τ 1 and TE, and focus on capturing the relaxation constants slow and fast by incrementing τ 1. 19 This sequence was employed for 23Na TQC measurement with an 8‐step phase cycling, proposed to measure directly the T2 relaxation. 20 Its advantage is a signal acquisition free of assumptions on the sample(s) relaxation parameters. The TQ(T)PPI with optional increments of the evolution time was used by Refs. 1, 20 with a phase shift of = +π/2. An additional 8‐step phase cycle with = −π/2 was proposed to eliminate DQC with ϕ 1 1st_cycle = ϕ 1 2nd_cycle.
Third, option III, a 2 × 6‐steps cycle for recovering signal cancellation due to deleterious effects of B0 inhomogeneity, was proposed by Fleysher et al. 21 In MRI, B0 inhomogeneity can be severe and lead to spins dephasing and MQC signal loss. An additional 6‐step phase cycle was introduced with phase shift = 0 (Table 1). Gradient spoiling during evolution time would be an alternative to mitigate B0 inhomogeneity impact but lowers the SNR due to the spoiling of half the coherence pathway contributions.
Fourth, option IV uses 4 × 6 steps phase cycling to avoid bias due to T1‐weighted STE signals, presented by Fiege et al. 22 Signal bias can arise due to STE signal for which a solution, the SISTINA sequence, was proposed by Tanase and Boada 13 and Fiege et al. 22 In general, a 3‐pulse sequence can form a STE signal 23 , 24 , 25 that could give an unwanted bias. An additional phase cycle was introduced with a phase shift of . SISTINA chose two 6‐steps phase cycles, with phase shifts , to eliminate STE signal. B0 inhomogeneity was compensated for with 2 extra phase cycles, for a total of 4 phase cycles, using the same approach as in option III.
In the following, the impact of STE versus B0 offset was investigated to make a founded choice, our option V, for optimal MQC measurement.
3. METHODS
3.1. Simulation
For the formulation of the signal equations, Fleysher et al 21 formalism was chosen, and detailed description can be found (https://github.com/MHoesl/MQC_Simulation). The coherence levels after the first and second RF pulses are denoted by p1 and p2, respectively. The matrix Ap 1, p 2 was specified as the amplitude of the respective coherence pathway:
An initial amplitude set (SQ, DQ, TQ) for the coherence level transfers is thus divided into its multiple possible pathways. For example, there are 4 possibilities for the TQC (drawn in green in Figure 1C). One of these 4 pathways starts from the coherence level p1 = −1 after the first pulse. The second pulse transfers to the coherence level to p2 = −3, resulting in the signal from T 3‐3. The received signal, S, cumulates all coherence pathways and is expressed as:
| (1) |
The parameter Ω (Hz) in the term BNa describes the off‐resonances effects for simulation of magnetic field inhomogeneity. Theoretically, the signal S is nulled for:
Details can be found in Supporting Information Calculation S1. 26 For the first simulation part, relaxation terms were omitted. For the second simulation part, the following equations were formulated to take into account relaxation effects within the amplitude matrix Ap 1, p 2. SQ signal was described by the biexponential decay separated into slow and fast components and the excitation angle :
| (2) |
For the DQ and TQ coherence signals, the relaxation terms are given by:
| (3) |
The STE signal depends on the flip angle (or B1+), relaxation effects, and B0 inhomogeneity, and was described as follows:
| (4) |
| (5) |
The maximum of BSTE, with respect to the TE, is found for TE = τ 1. We used the following parameter values in accordance with realistic measurement values: τ 1 = 10 ms, τ 2 = 100 μs, slow = 30 ms, fast = 4 ms, and T1 = 70 ms. All 3 flip angles were set to π/2. The MQC signal contributions, which populate the matrix A p 1, p 2, were set to 1.0, 0.5, and 0.3 for the SQ, DQ, and TQ coherences, respectively, to ease visualization. Assuming sufficiently long TR values (> 120 ms), notably to fit practical SAR limitations in MRI, T1 relaxation was further neglected in the simulations.
SIGNAL RECONSTRUCTION: MQC signals can be separated by their scaled evolution frequencies, as defined by their phase term . The spectrum signal is thus reconstructed by Fourier transformation along the phase dimension ϕ 1. According to Fleysher, the signals, S, of the 2 phase‐cycles, are transformed independently:
| (6) |
denotes the spectrum, normalized to the size of the signal to obtain correct Fourier transformation amplitude values. The 2 spectra are combined to .
| (7) |
A fully recovered spectrum, can be calculated if the B0 offset, , is known. Signal dephasing occurs during the evolution time and the TE, and the signal can be recovered with its phase:
| (8) |
For the SISTINA reconstruction, in total 4 cycle‐signals (4 × 6 steps) were proposed to offer a full reconstruction correcting for STE signal and B0 offset. But in vivo SISTINA acquisitions were limited to phase cycles 1 and 2 only. Thus, the reconstruction was reported as individual signal Fourier transformation and sum‐of‐squares combination:
| (9) |
| (10) |
The signals, S, and resulting spectra, were simulated for 1) the original 6‐step phase cycle as well as the highlighted options, 2) 2 × 8‐step TQ(T)PPI phase cycle, 3) the 2 × 6 step phase cycles of Fleysher, and 4) the 4 × 6 phase cycles of the SISTINA sequence.
3.2. Experimental acquisitions
To complement the simulation work, measurements on 2 phantoms and in the brain of 5 healthy volunteers were performed. Experiments were performed on 7 T MRI (Siemens Magnetom, Erlangen, Germany) with a 1Tx/1Rx dual‐tuned 1H/23Na head coil (QED, Cleveland, OH). One phantom was a simple bottle of saline water. The second phantom consisted of 8 × 60 mL tubes, with varying concentrations of agarose (0%‐5%) and 23Na (50‐154 mM). The study was approved by local ethical committee, and volunteers were recruited after providing informed consent according to the Declaration of Helsinki. Three vials were placed next to the head, with concentrations of agarose and 23Na of: (4% 100 mM), (% 50 mM), and (2% 100 mM) to allow subsequent calculations of tissue sodium content and comparison of TQ signal. A multi‐echo Cartesian MQC imaging sequence was developed that features the possibility of easy switching between different phase cycle choices by variable , , and phase shift . A Cartesian readout was chosen for efficiency and ease of reconstruction, as well as because the TQC signal of interest is maximal at a later TE (Figure 1B). Efficiency considerations included the number of measured points per phase cycle and the use of a multi‐echo readout, which allows signal capture of both TQC (later TEs) and SQC (early TEs), as well as the possibility of reconstructing a B0 map directly from the data. was conservatively chosen to be 30°, which results in a twofold oversampling of the TQC frequency. The 12‐steps phase cycle of 2π was averaged over 10 repetitions in phantom and 12 repetitions in vivo. Other parameters were: 32 × 32 matrix size with twofold oversampling in readout direction, FOV of 200 mm (phantom) and 250 mm (in vivo), bandwidth of 330 Hz/Px, and 2D slice thickness of 20 mm. CRISTINA phase cycles were chosen identical to option III based on the simulation results for acquisition of B0‐unbiased TQ signal. The multi‐echo readout included 20 TEs, with TE1 = 1.15 ms (asymmetric echo) and ∆TE = 3 ms. The TR was 390 ms due to SAR restrictions, and acquisition time was 25 minutes (phantom) and 29 minutes (in vivo) per cycle, which corresponds to 50 minutes and 58 minutes total acquisition time, respectively. The optimal evolution time was determined experimentally from a TQTPPI global spectroscopic prescan (scan time 1‐2 minutes) and a subsequent offline fit. Thus, employed values were: 10 ms in the first phantom (no optimization for pure saline water), 13 ms for the second phantom, and 9.2 ± 1.4 ms for in vivo brain.
In the saline water bottle, a 1D strong static magnetic gradient was applied (~10 Hz/1 cm) to induce offresonance artifact. CRISTINA was compared to its counterpart SISTINA with in vivo phase cycles, 22 , 27 as defined in Table 1. Because SISTINA uses 6‐step phase cycles, the number of averages was set to 20 to match CRISTINA total acquisition time.
3.3. Experimental data analysis
The first 2 echoes from CRISTINA phase data served to map 23Na signal off‐resonance (B0). Combining CRISTINA 2 phase cycles ( ), a voxel‐wise multiparametric fit of 23Na signal parameters was performed, providing maps of slow and fast using Equations (2) and (3) and including a Direct Current component to account for background noise. The minimum of the multivariable function was approached with GlobalSearch and fmincon solver in Matlab 2019 (MathWorks, Natick, MA). The value of TQC at TE = 0 ms is 0 from theory and was added to the multi‐echo data to enhance the fit. The SQC signal at TE = 0 ms was obtained by extrapolation of the fit result, thus enabling an estimate of a 0 TE 23Na signal. The fit function included both fast and slow compartments. The fit’s lower boundary of the fast component amplitude was set to 0 to enable the finding of a mono‐exponential solution. Thus, both biexponential and mono‐exponential solutions could arise.
In the second phantom, the fitted values were evaluated in circular regions of interest centered over each of the 8 phantom tubes independently, avoiding partial volume effect. Tissue 23Na concentration to signal relationship was evaluated in the region of interest for the SQC image at TE = 0 ms. TQC image at TE = τ 1, normalized by SQC image at TE = 0 ms, was plotted against agar percentage and provided TQ/SQ ratio.
Finally, the SNR was evaluated for phantom and in vivo data on the separated SQ and TQ images over TE. Average signal was measured within the 6‐pixel eroded body mask, and noise was evaluated in the complement image of an equivalently dilated body mask to avoid edges.
4. RESULTS
4.1. Simulation
The simulation of the original 6‐steps phase cycle with neither B0 inhomogeneity, Ω, nor relaxation effects, option I, is presented as Supporting Information Figure S1 for completeness. The choices for the 6 samples appear relevant to measure the full amplitude of the TQC signal, whereas DQC is not optimally sampled. Also, the choice for 6 samples places the TQC signal at the Nyquist limit. Fourier Transformation along the evolution phase ϕ 1 recovers the amplitudes of the mixed signal of (SQ, DQ, TQ) = (1.0, 0.5, 0.3). The amplitudes in the spectrum do not have a Lorentzian shape because the phase cycle does not capture relaxation processes.
Second, regardless of the time increments (ie, the name TQ(T)PPI), the TQPPI samplings for the 2 phase‐cycles with ξ\, = ±π/2 are depicted in Figure 2 (see option II). It is demonstrated that the phase increment choice of 45° oversamples the TQC signal. Specifically, the 45° phase increment samples the maximum of the TQC signal only in 2 out of 8 points, with 4 points falling short of measuring the maximum point. In contrast, the sampling points measure optimally the maximum amplitude of the DQC signal, which is opposite in signal for the 2 cycles and hence cancels out when the signals are combined. Without considering B0 offset, the SQC and TQC signal is equivalent for the 2 cycles, with the signal ending up only in the imaginary channel. When relaxation processes and B0 offsets (100 Hz range) are included (Figure 3), an oscillatory pattern for all quantum coherences was observed with occurrences of complete signal loss. Signal cancellation can be observed for the 2 phase‐cycle signals S1, S2, and the reconstructed spectra at the same frequency offset (25 Hz and 75 Hz). The signal dropouts can be obtained from Equation (1) for Ω = (kπ + π/2)/2π = (2k + 1)/4 , k ∈ , which corresponds to the measured dropout values. Further, it can be observed that the DQC signal suppression is also achieved when relaxation processes are considered and a B0 offset alters the signal. Whereas the MQC magnitude signal is equivalent for the 2 cycles, the phase images show opposite signs for the DQC signal.
FIGURE 2.

Option II: TQ(T)PPI phase cycling. The SQC and DQC are optimally sampled; however, the TQC maximum is only sampled at 2 out of 8 points. Evolution time increment and relaxation have been discarded. The sum of the 2 cycles signals effectively cancels out DQC signal. In the resulting spectra, the DQC cancellation can be observed by FT of the beforehand added signals, and oversampling leads to TQC being split in 2 components. FT, Fourier transform; SQC, single‐quantum coherences; TQ(T)PPI, triple‐quantum (time) proportional phase increments
FIGURE 3.

Option II: TQ(T)PPI simulation including relaxation and B0 offset. The magnitude and phase of the signals at ϕ 0 are shown independently for the 3 quantum coherences: (A) SQC, (B) DQC, and (C) TQC. The complex DQC signal (row II) shows signal cancellation due to opposite phases for the 2 phase‐cycles. For the SQC and TQC signals, signal addition is constructive. (D,E) The spectra for the individual phase cycles (ξ= ± π/2), as well as for the added signals in (D) along the B0 offset and (E) along the TE. Signal cancellation at 25 and 75 Hz can be observed
The third phase cycling, option III, dubbed here Fleysher’s, 21 recognized the dramatic signal loss due to B0 inhomogeneity. The benefit of Fleysher’s 2 cycles along with its reconstruction is explained in Figure 4, option III, for an exemplary offset of 10 Hz. The full recovery of the signal (neglecting relaxation) can be seen directly in the amplitude values of the spectrum reco.
FIGURE 4.

Option III: Fleysher cycles for recovering B0 offset bias of 10 Hz. (A), (B) show the signal, S1 and S2, along the phase cycle for ξ = π/2, 0.(C) and (D) show the individual Fourier transformed amplitudes highlighting that some signal ended up in the S2. Their addition and subtraction ±, in combination with a reverse of the known B0 offset, result in the recovered spectrum (E). The amplitudes in (E) are the initially set values for the simulation, which shows that the signal was effectively recovered, reversing the B0 offset effect
The full simulation, including relaxation and a range of 100 Hz offsets, shows again an oscillatory pattern for the MQC signals along the B0 offset, with occurrences of complete signal loss (Figure 5). The key point is that the 2 cycles are complementary in exhibiting signal cancellation and signal maximum. The signal dropouts of the second cycle, ξ = 0, are obtained for Ω = (k π+ 0)/2π = k/ . For our set of simulation parameters for example at an offset of Ω = ±25 Hz, the signal is recovered in the second phase cycle while being completely canceled in the original phase cycle. The oscillation of the original signal thus has a counterpart in the additional phase cycle.
FIGURE 5.

Option III: Fleysher cycles, along TE (0 ms–50 ms) and varying B0 offset from 0 Hz up to 100 Hz. Magnitude and phase signal are shown for the SQC (A) and TQC (B) to show the differing oscillation due to B0 offset. This offers the possibility of signal reconstruction, shown in the spectra data in (C). Signal evolution with differing signal maxima of SQC and TQC signal along TE is given for no B0 offset. Then the spectra are given at TE = 10 ms along a B0 offset from 0 to 100 Hz. Signal vanishing can be observed at 25 and 75 Hz offset in the first cycle and at 0, 50, and 100 Hz in the second cycle. The reconstructed spectrum is independent of the B0 field offset. CRISTINA makes use of the same 2 phase cycles
The simulation results, including STE mitigation, can be found in Supporting Information Figure S1. The STE signal can overlap with MQC signals and shows a relative maximum signal at an TE equal = 10 ms, which coincides with the maximum signal of the TQC signal (Figure 5). The STE phase signal is the opposite for phase cycles proposed by SISTINA; thus, the sum of the complex STE signals of the 2 cycles cancels out.
However, considering STE signal expression, one can observe that STE is independent of the phase increment ϕ 1 because its phase term is . Thus, STE signal can be considered as a zero‐quantum coherence signal (Supporting Information Figure S2). Finally, inserting measured B0 offset into Equation (5) of the STE signal can nullify STE signal within the reconstruction. The alternatively proposed sum‐of‐squares magnitude reconstruction, as indicated in the SISTINA publication, 22 still showed the STE signal as an offset.
Figure 6 compares the complete signal recovery from 2 cycles, as defined in Fleysher and presently, to the signal from the 4 cycles defined in SISTINA (see Table 1). B0‐induced signal nulling in 1 and 2 was compensated for using paired cycles 3 and 4, as shown in the reconstructed combination 1+ 3 (Figure 6B). However, SISTINA choice to prefer the first cycles S1 and S2 for all in vivo experiments remains sensitive to B0‐induced signal loss.
FIGURE 6.

A, Option III and V phase cycle recovers signal from B0‐induced signal loss using only 2 cycles. B, Option IV assumed 4 cycles necessary to recover the signal, and most importantly, prioritized the first 2 cycles for all in vivo experiments. This combination led to remaining B0‐induced signal loss. C, Experimental results from a homogeneous phantom with induced strong B0 gradient. Images are scaled identically. Excellent signal recovery is demonstrated from CRISTINA (option V), whereas SISTINA (option IV) shows dark bands spaced regularly by 1/(2 ) = 50 Hz in this case. Signal loss ranges from 20% to 50% due to partial volume effect from large voxel size
In summary, it appears crucial to compensate for B0 offsets, whereas STE is inherently isolated upon Fourier transform of the MQC signals, as is DQC. Thus, an efficient choice for MQC measurements is Fleysher’s 2 × 6‐steps phase cycles. But SISTINA’s design offered an interesting addition by electing for a multi‐TEs readout to sample MQC signals along time (alas, in a larger raster time than TQ(T)PPI). Therefore, the combined design of 2 × 6‐steps phase cycles and a multi‐echo CRISTINA was implemented and investigated on phantoms and in vivo in the following.
4.2. Experimental measurements
Experimental comparison of CRISTINA and SISTINA shown in Figure 6C confirms SISTINA sensitivity to B0 when using only the 2 in vivo cycles, whereas CRISTINA design allows for a B0‐resilient reconstruction of SQC signal (and by extension TQC). The signal loss between CRISTINA and SISTINA oscillates between 20% and 50% due to intravoxel signal averaging within large acquired voxels.
Figure 7 shows experimental design, including the CRISTINA sequence diagram (A), raw images (B), and the postprocessing results (C) exemplary from 1 voxel as well as for the whole image. The estimated from a TQTPPI global spectroscopic prescan (scan time ~30 seconds) was 13.3 ms. Two series of 4D images were obtained with the dimensions being x, y, TE, and ϕ 1. The Fourier transform along the repeated (10×) phase cycle dimension ϕ 1 over the complex signal images showed the MQC spectrum as anticipated from the simulations. Selecting single and triple quantum coherence frequencies, the SQ and TQ images were reconstructed. Subsequently, + and − were calculated. A B0 map was also computed using the phase difference (unwrapped) between the first 2 TE after quadrature combination of the 2 phase‐cycles and averaging over phase cycle steps. Eventually, total SQC and TQC signal images were reconstructed for each TE. Data and processing results for a single voxel can be found in the Supporting Information Figure S3, with the intention to enhance comparability to the simulation results.
FIGURE 7.

A, 2D multi‐echo sequence scheme B, initial phase cycle signal image at D, from the phase cycle data; the spectroscopic images were reconstructed by voxelwise FT for each TE set. ± were calculated. The B0 map was calculated from quadrature combination of the 2 cycles and the multi‐TE experiment. Using the voxelwise B0 offset values, the total spectroscopic result, total, was reconstructed. A complex signal depiction of a voxel of interest in phantom 5 can be found in Supporting Information Figure S3
A subsequent multiparametric fit for the SQC and TQC signals (Equations (2) and (3)) was performed voxel‐wise along the TE data, enhanced by the prior knowledge that TQC is 0 at TE = 0 ms. The results are presented in Figure 8. The SQC signal evolution fit over the multiple TEs allowed for extrapolation of the SQC signal to TE = 0 ms. The TQC signal image is shown for TE = = 13.3 ms. Exemplary, the signal evolution measurement data with the corresponding fit results are shown for the 8 center voxels of the phantom vials along TE, in range of 0 to 60 ms, separately for the SQC and TQC signal (Figure 8H,I). The characteristic signal evolution of SQC and TQC signals from the simulation was confirmed. Eventually, fast and slow maps were produced from the multiparameter fit with values in the range of 0 to 12 ms for fast and 15 to 30 ms for slow. The liquid phantom vial followed essentially a monoexponential decay for most pixels. The 2% agar vial in the center showed elevated fast values in the range of (11.0 ± 2.7 ms) and lower long values of (21.9 ± 3.1 ms) compared to the 4% and 5% agar phantoms with fast in the order of 5 ms and long in the order of 27 ms.
FIGURE 8.

A, Fitted SQ signal, extrapolated to TE = 0 ms. The colorbars show the signal strength and the sodium concentration in mM by a linear fit using the (2%, 130 and 100 mM) phantoms for calibration. Phantoms are numbered for the following: B, TQ signal at TE 13.3 ms with higher signal strength in phantoms 3 and 5 (4%, 5% agar, 154 mM). C, TQ to SQ ratio relates to agar values, independent of 23Na content. D, E, slow and fast maps by voxelwise fit. The liquid phantom 1 showed a monoexponential result and therefore has values close to 0. F, TQ to SQ ratio is visualized against agar concentration and showed a linear relationship (R 2 = 0.87). G SQ signal at TE = 0 ms showed a linear relationship to 23Na concentration (R 2 = 0.75). Values in (F,G) were evaluated and averaged over the tube size. H, SQ signal over TE and fit, only 4 phantoms, different in agar and sodium concentration, are depicted to ease visual comparison. I, TQ signal over TE time and fit. slow and fast values, along with the concentrations of each of the numbered phantoms, can be found in the Supporting Information Table S1 and summarizes all resulting values
Further, mean SQC signal evaluated in region of interest at TE = 0 ms showed a linear relationship against total 23Na content in mM (R 2 = 0.75, P value = .0058). For the mean TQC signal, normalized by SQC at TE = 0 ms, a higher signal strength was observed for increased agar content, regardless of the 23Na concentration (R 2 = 0.87, P value = 0.0007). However, for the 4% and 5% agar content, the mean TQC/SQC difference was within the ROI SDs.
Feasibility of in vivo CRISTINA is demonstrated in Figure 9. CRISTINA shows excellent resilience to B0 inhomogeneity, such as in the first volunteer in which B0‐shimming was not iterated. SQ images at TE = 1.15 ms exhibit expected 23Na distribution in the brain despite significant partial volume effect of cerebrospinal fluid due the thick prescribed 2D slice (20 mm).
FIGURE 9.

A, B, T2w image and the 2D slice position for the sodium acquisition in coronal and axial view. Phantoms are indicated with (x, *, o) for (100 mM and 4% agar, 50 mM and 4% agar, 100 mM and 2% agar). C, initial phase cycle signal at for the first cycle D, reconstructed SQ image for the first cycle. E, F, TQ images for both cycles. G, B0 map leading to the total spectroscopic signal, total. To enhance SNR, the TQ images are averaged from the 2nd to the 7th echo, which equals the TEs from 4 to 18 ms
SQ images SNR were comparable between phantom and in vivo data (76 ± 27 vs. 80 ± 11, respectively, for the first TE). However, TQ SNR in vivo was much lower compared to phantom (14 ± 7 vs. 5 ± 0.5 at TE = 10 ms). Therefore, voxelwise signal fitting was not deemed reliable in vivo (Supporting Information Figures S4 and S5).
5. DISCUSSION
In this study, the rationales for the various sequence designs for MQC 23Na‐MRI measurement were considered in a unified formalism, theoretically and graphically. From the improved understanding of the different options, an efficient design was proposed to compensate for B0 and stimulated echo in only 2 × 6‐steps phase cycles. The proposed CRISTINA sequence further leveraged multi‐echo readout to rapidly sample MQC signal temporal evolution. Eventually, CRISTINA data were enhanced by the unified formalism to draw a complete characterization of the 23Na signal, including B0, relaxometry, and total signal of both SQC and TQC.
Although different options have been presented over the last decades, an overview and comparison between the various techniques was lacking. Furthermore, we presented a graphical and intuitive formalism to simulate the techniques of coherence transfer and phase cycling, with publicly available code for reproducibility.
The understanding of the different options for measuring TQC signal, along with the resulting efficient phase‐cycling choice, are especially important because 23Na MR techniques are on the rise thanks to hardware improvements. Eventually, probing MQC signal in 23Na MRI allows full capture of the underlying physical properties within each voxel. Indeed, as shown in Figure 8, both compartments relaxation properties and total 23Na concentrations can be inferred provided that a calibrated sample is within the imaging plane. Thus, the pairing of the common theoretical framework presented above with the experimental design for efficient MQC 23Na MRI can provide refined tissue characterization and hence diagnostics and treatment monitoring.
Simulation results showed that the conventional 6‐step phase cycle is, expectedly, most susceptible to B0 inhomogeneity. The additional phase cycle with a phaseshift of 0° for B0 inhomogeneity mitigation effectively alleviates the problem.
The TQTPPI method proposed a different second phase cycle to suppress DQC signals. However, the DQC signal is differentiated by Fourier decomposition and ends up at twice the single quantum coherence frequency, whereas the TQC signal ends up at 3 times the SQC frequency. Therefore, the additional cycle for DQC transfer suppression doubles the measurement time with merely an averaging repetition of the SQC and TQC signal. The 45° (2π/8) phase increment oversamples TQC and misses capture of the full TQC signal amplitude. The Nyquist sampling frequency is twice the highest frequency of interest, resulting in a maximum phase increment of 60° for efficient TQC sampling. Any smaller phase increment results in oversampling and serves to accumulate signal, which can be substituted by averaging. The advantage of the TQTPPI method using time proportional phase increments is given in the possibility of obtaining the long and short values from the fit of the signal along the evolution time without prior knowledge of the optimal evolution time. A standard phase‐cycle with fixed evolution time τ 1 and 1 single echo readout in an imaging experiment cannot provide this information. The Fleysher’s 2‐phase cycles choice focused on the B0 offset mitigation. This design effectively helps resolve any lost signal and remove STE and DQC signals impact while operating at the Nyquist frequency.
The SISTINA design focused on 4 phase cycles to suppress stimulated echo signals. Although the stimulated echo signal is the highest at the time point of the maximum TQC signal, the stimulated echo signal assimilates to a zero‐quantum coherence signal, that is, as a continuous offset, after Fourier decomposition. SISTINA’s interesting aspect was the multiple echo readout that allows capture of the temporal evolution of both SQC and TQC. A further addition of the SISTINA sequence 22 , 27 was the use of the “dead” time between the first and the second pulse for 1 or multiple UTE readouts. These additional measurements can serve to improve the overall SNR; however, combining UTE and further Cartesian images with proper signal scaling is nontrivial. Our CRISTINA results also demonstrate complete SQC signal characterization without UTE sampling.
Eventually, CRISTINA added values over SISTINA are multiple and arise from the proposed theoretical framework that was incomplete in the SISTINA design 28 :
First, SISTINA considered 4 cycles to be necessary to complete 23Na signal characterization. As demonstrated in Figure 6, CRISTINA 2 cycles suffice to compensate B0‐induced signal loss and phase cycling inherently separates STE from MQC signals. Thus, in vivo SISTINA results have been limited to B0 homogeneity under (2k + 1)/(4 × 7 ms) = ±35 Hz 27 and (2k + 1)/(4×6 ms) = ±42 Hz, 22 with k . Second, CRISTINA relies only on Cartesian sampling, whereas SISTINA is based on a joint model including half‐radial UTE signal sampling and Cartesian sampling. UTE sampling is dedicated to measure rapidly decaying signal but suffers from accrued sensitivity to hardware imperfections 29 that usually require platform‐depend tuning and corrections. Utilizing Cartesian sampling may facilitate reproducibility across platforms and avoid the issue of scaling UTE and MQC Cartesian signals to jointly model signal relaxation.
Finally, CRISTINA additionally provides a B0 map that can serve the model from Equation (8). If B0 values were unavailable, a quadrature combination of the 2 cycle can be substituted, alas without exact signal phase.
Thus, an efficient MQC 23Na‐MRI sequence design named CRISTINA was drawn that benefits from the efficient Fleysher’s 2 × 6‐steps phase cycles, in combination with SISTINA multi‐echo readout to mimic TQTPPI assumption‐free signal sampling. CRISTINA leads to a complete characterization of 23Na signal, including B0, relaxation times, and MQC signals.
5.1. Experimental proof of concept
CRISTINA design was empowered by the theoretical formalism to extract MQC signals free of B0, DQC, and STE biases. The reconstruction of the acquired Cartesian MQC data can be done straightforwardly using Fourier transform. B0 can be mapped using a simple least‐square fit of the phase data. A multiparametric fit results in fast and slow maps as well as quantification values for SQC and TQC signals. The asymmetric echo choice reduced the lowest possible TE to 1.15 ms. With extrapolation of the fit, a TE = 0 ms SQC image can be reconstructed, which allows total 23Na content quantification without bias due to differing decay rates. Therefore, all relevant information for quantification methods can be obtained with the sequence.
Further optimization remains to be considered regarding acquisition parameters such as TE sampling and receiver bandwidth. Currently, the phantom measurement took 25 min per phase cycle but was chosen with conservative values of twofold oversampling the TQ frequency by ∆ϕ = 30° and measurement of 10 full phase cycles for averaging. The total measurement time of 50 min could, therefore, be reduced by ∆ϕ = 60° and fewer phase cycles. The matrix size of 48 × 32 was chosen, and the higher resolution was achieved by zero filling. Individual phantom vials could potentially suffer from a partial volume effect due to the 2D acquisition with chosen slice thickness of 20 mm and imperfect parallel alignment of the vials; additionally, high agar concentrations can lead to an inhomogeneous gel distribution, and both can explain deviations between similar vials.
In vivo measurements were successfully conducted with the same parameters. Twelve full cycles were acquired, which resulted in an acquisition time of 29 minutes per cycle. Further tests in vivo are necessary to reduce the measurement time and for higher resolution scans without sacrificing SNR in the TQ image. Postprocessing of the cycle repetitions and the multiparametric fit could be optimized in the future by, for example, using a neural network approach 30 , 31 and even considering the multiple dimensions instead of working voxel per voxel. Moreover, it must be noted that, at present, CRISTINA remains a 2D imaging sequence, and for the presented measurement set a relatively thick slice of 20 mm was used. To overcome partial volume effects, the presented CRISTINA will be extended to 3D measurement in the next step. (Phantom measurement raw data and reconstruction code can be found here: https://github.com/MHoesl/MQC_Imaging_CRISTINA).
6. CONCLUSION
We presented a full simulation analysis of the different possible phase cycles for 23Na multi‐quantum MRI and highlighted their benefits and shortcomings. An efficient sequence design was drawn, resulting from the simulation work, and implemented on a clinical MRI. An experimental proof of concept on a phantom shows promising results for a complete characterization of the multiquantum 23Na signals.
Supporting information
TABLE S1 Mean phantom values, evaluated in a circular ROI of phantom diameter size. The four smaller diameter phantoms were not taken into account and served to see if smaller structures can be resolved
FIGURE S1 Option I: Original six step phase cycle: A, The three coherence signals contributions over the evolution phase ϕ 1 dimension. Circle markers highlight sampling values for phase increment of 2π/6 and start phase of π/6. B, Fourier Transform splits the MQC contributions and thus allows to separate the three contributions SQ, DQ and TQ, with TQ signal at the Nyquist horizon
FIGURE S2 Stimulated echo signal (STE) arises from the 3‐pulses scheme and occurs at TE= . STE signal can overlap with MQC signals, which can be seen in (A) and shows a relative maximum signal of 0.16 (red cross) at an echo time of TE= = 10 ms which coincides with the maximum signal of the TQC signal However, filtering for MQC signals imposes RF phase cycling that isolates STE as a zero‐quantum (ZQC) signal. Beyond isolating STE signal using phase cycling, inserting off‐resonance values into Equation (5) allows the reconstruction to completely null STE signal
FIGURE S3 For better comparison to the simulation data, a single voxel of interest within Phantom 5, 154 mM Na, 5% agar is presented. A,B, image data with the voxel of interest marked by a cross. C, Real and Imaginary parts of the two cycles are plotted along ϕ 1 with the circular markers indicating data acquisition. D,E, spectroscopic result along the multiple echo times. (D) TQ signal can be seen well (E) no visible TQ signal in (E). F, The data are reconstructed to a total spectroscopic result free of B0 inhomogeneity bias
FIGURE S4 Signal to noise ratio (SNR) over echo time, TE. A, SNR was calculated as the mean signal in the foreground divided by the standard deviation of the background noise region. Foreground region was defined using an eroded bodymask after manual thresholding. Background region was defined using the complementary mask after dilation to exclude measurements from boundary signal. Reported in vivo SNR has been averaged over the 5 healthy volunteers. B, TQ SNR for the individual phantom vials, evaluated in a manually selected circular region that excluding edges
FIGURE S5 An exemplary one voxel fit in the indicated region for each of the 5 volunteers is given. Further development of the fitting routine is necessary to allow the fit in vivo in reasonable time on low SNR images with larger FOV and smaller voxels
Acknowledgment
This article is based in parts upon work from COST Action “CA16103 Assessment of Kidney Physiology using 23Na triple quantum spectroscopy,” supported by COST (European Cooperation in Science and Technology). This work was performed by a laboratory member of France Life Imaging network (grant ANR‐11‐INBS‐0006). This work was performed on the platform 7 T‐AMI, a French “Investissements d’Avenir” programme” (grant ANR‐11‐EQPX‐0001).
Hoesl MAU, Schad LR, Rapacchi S. Efficient 23Na triple‐quantum signal imaging on clinical scanners: Cartesian imaging of single and triple‐quantum 23Na (CRISTINA). Magn Reson Med. 2020;84:2412–2428. 10.1002/mrm.28284
Lothar R. Schad and Stanislas Rapacchi contributed equally to this work.
REFERENCES
- 1. Jaccard G, Wimperis S, Bodenhausen G. Multiple‐quantum NMR spectroscopy of S=3/2 spins in isotropic phase: a new probe for multiexponential relaxation. J Chem Phys. 1986;85:6282. [Google Scholar]
- 2. Bodenhausen G, Kogler H, Ernst RR. Selection of coherence‐transfer pathways in NMR pulse experiments. J Magn Reson. 1984;58:370‐388. [DOI] [PubMed] [Google Scholar]
- 3. Bodenhausen G, Vold RL, Vold RR. Multiple quantum spin‐echo spectroscopy. J Magn Reson. 1980;37:93‐106. [Google Scholar]
- 4. Pekar J, Leigh JS. Detection of biexponential relaxation in sodium‐23 facilitated by double‐quantum filtering. J Magn Reson. 1986;69:582‐584. [Google Scholar]
- 5. van der Maarel JRC. Relaxation of spin quantum number S=3/2 under multiple‐pulse quadrupolar echoes. J Chem Phys. 1991;94:4765. [Google Scholar]
- 6. Romanzetti S, Mirkes CC, Fiege DP, Celik A, Felder J, Shah NJ. Mapping tissue sodium concentration in the human brain: a comparison of MR sequences at 9.4 Tesla. Neuroimage. 2014;96:44‐53. [DOI] [PubMed] [Google Scholar]
- 7. Thulborn KR. Quantitative sodium MR imaging: a review of its evolving role in medicine. Neuroimage. 2018;168:250‐268. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8. Wagner D, Anton M, Vorwerk H. Dose uncertainty in radiotherapy of patients with head and neck cancer measured by in vivo ESR/alanine dosimetry using a mouthpiece. Phys Med Biol. 2011;56:1373‐1383. [DOI] [PubMed] [Google Scholar]
- 9. Hu R, Kleimaier D, Malzacher M, Hoesl MAU, Paschke NK, Schad LR. X‐nuclei imaging: current state, technical challenges, and future directions. J Magn Reson Imaging. 2020;51:355‐376. [DOI] [PubMed] [Google Scholar]
- 10. Hoesl MAU, Kleimaier D, Hu R, et al. 23Na Triple‐quantum signal of in vitro human liver cells, liposomes, and nanoparticles: cell viability assessment vs. separation of intra‐ and extracellular signal. J Magn Reson Imaging. 2019;50:435‐444. [DOI] [PubMed] [Google Scholar]
- 11. Van Der Maarel JRC. Thermal relaxation and coherence dynamics of spin 3/2. I. Static and fluctuating quadrupolar interactions in the multipole basis. Concepts Magn Reson. 2003;19A:97‐116. [Google Scholar]
- 12. Van Der Maarel JRC. Thermal relaxation and coherence dynamics of spin 3/2. II. Strong radio‐frequency field. Concepts Magn Reson. 2003;19A:117‐133. [Google Scholar]
- 13. Tanase C, Boada FE. Triple‐quantum‐filtered imaging of sodium in presence of B0 inhomogeneities. J Magn Reson. 2005;174:270‐278. [DOI] [PubMed] [Google Scholar]
- 14. Schepkin VD. Statistical tensor analysis of the MQ MR signals generated by weak quadrupole interactions. Z Med Phys. 2019;29:326‐336. [DOI] [PubMed] [Google Scholar]
- 15. Levitt MH. Spin Dynamics: Basics of Nuclear Magnetic Resonance. 2nd ed. Chichester: John Wiley & Sons; 2000. [Google Scholar]
- 16. Rooney WD, Springer CS. The molecular environment of intracellular sodium: 23Na NMR relaxation. NMR Biomed. 1991;4:227‐245. [DOI] [PubMed] [Google Scholar]
- 17. Kemp‐Harper R, Brown SP, Hughes CE, Styles P, Wimperis S. 23Na NMR methods for selective observation of sodium ions in ordered environments. Prog Nucl Magn Reson Spectrosc. 1997;30:157. [Google Scholar]
- 18. Navon G, Shinar H, Eliav U, Seo Y. Multiquantum filters and order in tissues. NMR Biomed. 2001;14:112‐132. [DOI] [PubMed] [Google Scholar]
- 19. Rance M, Sørensen OW, Bodenhausen G, Wagner G, Ernst RR, Wüthrich K. Improved spectral resolution in COSY 1H NMR spectra of proteins via double quantum filtering. Biochem Biophys Res Commun. 1983;117:479‐485. [DOI] [PubMed] [Google Scholar]
- 20. Schepkin VD, Neubauer A, Nagel AM, Budinger TF. Comparison of potassium and sodium binding in vivo and in agarose samples using TQTPPI pulse sequence. J Magn Reson. 2017;277:162‐168. [DOI] [PubMed] [Google Scholar]
- 21. Fleysher L, Oesingmann N, Inglese M. B0 inhomogeneity‐insensitive triple‐quantum‐filtered sodium imaging using a 12‐step phase‐cycling scheme. NMR Biomed. 2010;23:1191‐1198. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22. Fiege DP, Romanzetti S, Mirkes CC, Brenner D, Shah NJ. Simultaneous single‐quantum and triple‐quantum‐filtered MRI of 23Na (SISTINA). Magn Reson Med. 2013;69:1691‐1696. [DOI] [PubMed] [Google Scholar]
- 23. Burstein D. Stimulated echoes: description, applications, practical hints. Concepts Magn Reson. 1996;8:269‐278. [Google Scholar]
- 24. Hahn EL. Spin echoes. Phys Rev. 1948;73:580‐591. [Google Scholar]
- 25. Kingsley PB. Product operators, coherence pathways, and phase cycling. Part II. coherence pathways in multipulse sequences: spin echoes, stimulated echoes, and multiple quantum coherences. Concepts Magn Reson. 1995;7:115‐136. [Google Scholar]
- 26. Matthies C, Nagel AM, Schad LR, Bachert P. Reduction of B0 inhomogeneity effects in triple‐quantum‐filtered sodium imaging. J Magn Reson. 2010;202:239‐244. [DOI] [PubMed] [Google Scholar]
- 27. Worthoff WA, Shymanskaya A, Shah NJ. Relaxometry and quantification in simultaneously acquired single and triple quantum filtered sodium MRI. Magn Reson Med. 2019;81:303‐315. [DOI] [PubMed] [Google Scholar]
- 28. Burstein D, Springer CS Jr. Sodium MRI revisited. Magn Reson Med. 2019;82:521‐524. [DOI] [PubMed] [Google Scholar]
- 29. Tyler DJ, Robson MD, Henkelman RM, Young IR, Bydder GM. Magnetic resonance imaging with ultrashort TE (UTE) PULSE sequences: technical considerations. J Magn Reson Imaging. 2007;25:279‐289. [DOI] [PubMed] [Google Scholar]
- 30. Schnurr AK, Chung K, Russ T, Schad LR, Zöllner FG. Simulation‐based deep artifact correction with Convolutional Neural Networks for limited angle artifacts. Z Med Phys. 2019;29:150‐161. [DOI] [PubMed] [Google Scholar]
- 31. Lundervold A. Analysis of texture: practice. In Proceedings of the International Society for Magnetic Resonance in Medicine, Montréal, Québec, Canada, 2011. pp. 19‐20. [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
TABLE S1 Mean phantom values, evaluated in a circular ROI of phantom diameter size. The four smaller diameter phantoms were not taken into account and served to see if smaller structures can be resolved
FIGURE S1 Option I: Original six step phase cycle: A, The three coherence signals contributions over the evolution phase ϕ 1 dimension. Circle markers highlight sampling values for phase increment of 2π/6 and start phase of π/6. B, Fourier Transform splits the MQC contributions and thus allows to separate the three contributions SQ, DQ and TQ, with TQ signal at the Nyquist horizon
FIGURE S2 Stimulated echo signal (STE) arises from the 3‐pulses scheme and occurs at TE= . STE signal can overlap with MQC signals, which can be seen in (A) and shows a relative maximum signal of 0.16 (red cross) at an echo time of TE= = 10 ms which coincides with the maximum signal of the TQC signal However, filtering for MQC signals imposes RF phase cycling that isolates STE as a zero‐quantum (ZQC) signal. Beyond isolating STE signal using phase cycling, inserting off‐resonance values into Equation (5) allows the reconstruction to completely null STE signal
FIGURE S3 For better comparison to the simulation data, a single voxel of interest within Phantom 5, 154 mM Na, 5% agar is presented. A,B, image data with the voxel of interest marked by a cross. C, Real and Imaginary parts of the two cycles are plotted along ϕ 1 with the circular markers indicating data acquisition. D,E, spectroscopic result along the multiple echo times. (D) TQ signal can be seen well (E) no visible TQ signal in (E). F, The data are reconstructed to a total spectroscopic result free of B0 inhomogeneity bias
FIGURE S4 Signal to noise ratio (SNR) over echo time, TE. A, SNR was calculated as the mean signal in the foreground divided by the standard deviation of the background noise region. Foreground region was defined using an eroded bodymask after manual thresholding. Background region was defined using the complementary mask after dilation to exclude measurements from boundary signal. Reported in vivo SNR has been averaged over the 5 healthy volunteers. B, TQ SNR for the individual phantom vials, evaluated in a manually selected circular region that excluding edges
FIGURE S5 An exemplary one voxel fit in the indicated region for each of the 5 volunteers is given. Further development of the fitting routine is necessary to allow the fit in vivo in reasonable time on low SNR images with larger FOV and smaller voxels
