Skip to main content
Annals of Cardiothoracic Surgery logoLink to Annals of Cardiothoracic Surgery
. 2020 Jul;9(4):298–304. doi: 10.21037/acs-2020-surd-33

Sutureless and rapid deployment implantation in bicuspid aortic valve: results from the sutureless and rapid-deployment aortic valve replacement international registry

Antonio Miceli 1,, Paolo Berretta 2, Antonio Fiore 3, Martin Andreas 4, Marco Solinas 5, Giuseppe Santarpino 6,7,8, Utz Kappert 9, Martin Misfeld 10,11, Carlo Savini 12, Alberto Albertini 13, Emmanuel Villa 14, Kevin Phan 15, Theodor Fischlein 8, Bart Meuris 16, Gianluca Martinelli 17, Kevin Teoh 18, Carmelo Mignosa 19, Malakh Shrestha 20, Thierry P Carrel 21, Tristan D Yan 11,15, Mattia Glauber 1, Marco Di Eusanio 2,15
PMCID: PMC7415698  PMID: 32832411

Abstract

Background

Benefits of sutureless and rapid deployment (SURD) bioprostheses in bicuspid aortic valves (BAV) are controversial. The aim of this study is to report the outcomes of patients undergoing aortic valve replacement (AVR) for BAV from the Sutureless and Rapid-Deployment Aortic Valve Replacement International Registry (SURD-IR).

Methods

Of the 4,636 patients who received primary isolated SURD-AVR between 2007 and 2018, 191 (4.1%) BAV patients underwent AVR with SURD valve.

Results

Overall 30-day mortality was 1.6%. The Intuity valve was implanted in 53.9% of cases, whereas the Perceval was implanted in 46.1%. Rate of stroke for isolated AVR was 4.2%. No case of endocarditis, thromboembolism, myocardial infarction, valve dislocation or structural valve deterioration was reported in the early phase. Rate of pacemaker implantation and moderate-severe aortic regurgitation (AR) were 7.9% and 3.7%, respectively.

Conclusions

BAV is not considered a contraindication for the implantation of SURD valves. However, detailed information of aortic root geometry as well as the knowledge of some technical considerations are mandatory for a good outcome.

Keywords: Bicuspid aortic valve (BAV), aortic valve replacement (AVR), sutureless, rapid deployment valve

Introduction

Bicuspid aortic valve (BAV) is a common congenital defect which occurs in 1–2% of the general population. BAV is composed of two instead of three leaflets, and often associated with one raphe in one cusp. The most common morphology is the type 1 according to the Sievers classification (1). These leaflet alterations often induce progressive fibrocalcific stenosis requiring surgery. Interestingly, it has been estimated that more than 50% of all aortic valve replacements (AVR) for aortic stenosis are related to BAV (2).

Sutureless and rapid deployment (SURD) valves represent an excellent treatment option for surgical AVR, as they simplify the surgical procedure and reduce operative times (3-7). However, in the setting of BAV, these benefits are less clear. Despite several studies demonstrating good clinical outcomes, some reports suggest that SURD valves may increase the risk of paravalvular regurgitation and/or potential dislocation related to BAV aortic root asymmetry (8-12). Therefore, the aim of our study is to report the outcomes of patients undergoing AVR with SURD valves in patients with BAV from the Sutureless and Rapid-Deployment Aortic Valve Replacement International Registry (SURD-IR).

Methods

SURD-IR

The SURD-IR was established in 2015, enrolling patients at eighteen cardiac centres in Europe, Australia, and Canada. The study population was defined as patients undergoing SURD-AVR intervention using any available sutureless and rapid-deployment valve prosthesis either by conventional sternotomy or a less invasive approach. Valve prosthesis types included Perceval (Livanova PLC, London, UK) EDWARDS INTUITY/INTUITY Elite (Edwards Lifesciences, Irvine, CA, USA) and Enable 3F (Medtronic, MN, USA). AVR was performed via full sternotomy, ministernotomy and minithoracotomy. Details of the site selection and invitation as well as endpoints have been previously reported (5). Briefly, centers that had published reports on more than 50 SURD-AVR cases were initially invited to participate in the present database, as this was hypothesized to represent experienced centers with quality data collection. Further institutions recommended by the IVSSG Research Steering Committee were also invited to participate in the retrospective registry. Ethics approval was obtained at each of the participating centers, and datasets were submitted according to predefined spreadsheet format. Participating SURD-IR centers enrolled between 40 and 735 patients and collected information on demographics, patient comorbidities, functional status, imaging studies, surgical data, postoperative course, clinical and hemodynamic outcomes. Following electronic data submission, each dataset was evaluated to ensure that all patients were older than eighteen years. All variables between datasets were assessed with identical variables collated into a centralized database. Isolated variables reported by less than 25% of centers were excluded from analysis. Individually missing data and centre-specific non-reported data were coded separately. Clinically important absent data were queried with the submitting centre. Data were analyzed for clinical face validity and internal validity. Submitted clinical data were compared against published data for inconsistencies.

Patients selection

We examined 4,636 patients enrolled in the registry between April 2007 and December 2019. Exclusion criteria were tricuspid aortic valve, reoperative AVR and implantation of the off-market Enable 3F valve. The final sample included 191 patients with BAV who underwent AVR.

Statistical analysis

Continuous data were expressed as mean ± standard deviation and categorical variables as percentages. The Kolmogorov-Smirnov test was used to check for normality of data. Where continuous variables did not follow a normal distribution, the median and interquartile range were reported.

Results

Of the 4,636 patients who underwent AVR between 2007 and 2019, a total of 191 patients with BAV (4.1%) received SURD valves. Baseline characteristics are reported in Table 1. There were 92 (48.2%) male patients and overall mean age was 70.7±9.8 with a median EuroSCORE I and II of 5.8% (3.3–8.7%) and 1.6% (1–2.6%), respectively. The indication for AVR was aortic stenosis in 56% of the patients, mixed disease in 43.5% and regurgitation in 0.5%. Mean LVEF was 57.8%±9.9% and 3 patients presented with LVEF <30%.

Table 1. Baseline characteristics (n=191).

Characteristics Data
Male 92 (48.2)
Age 70.7±8.1
NYHA class
   I 14 (7.4)
   II 68 (36.2)
   III 98 (52.1)
   IV 8 (4.3)
Hypertension 105 (67.3)
Obesity 39 (20.5)
BMI 26.6±4.5
Diabetes 37 (22.0)
Dyslipidemia 75 (49.0)
AF 18 (13.7)
   LVEF% 57.8±9.9
   LVEF >50 157 (83.1)
   LVEF 30–50 29 (15.3)
   LVEF <30 3 (1.6)
   Aortic valve regurgitation 1 (0.5)
   Mixed aortic valve disease 83 (43.5)
Cerebrovascular disease 15 (8.3)
Renal insufficiency 50 (27.0)
Dialysis 1 (0.6)
CAD 44 (28.0)
Chronic lung disease 37 (20.1)
Redo 6 (3.1)
Urgent/emergent status 1 (0.6)
Logistic Euroscore, median (IQR) 5.8 (3.3–8.7)
Euroscore II, median (IQR) 1.6 (1–2.6)

Data present as n (%), mean ± SD, and median (IQR). NYHA, New York Heart Association; BMI, body mass index; LVEF, left ventricular ejection fraction; CAD, coronary artery disease; IQR, interquartile range.

Surgical procedure

Operative data are reported in Table 2. The majority of patients underwent a minimally invasive approach (73.8%). Specifically, ministernotomy was performed in 47.6% of procedures, followed by right anterior minithoracotomy (26.2%) and full sternotomy (26.2%). Associated procedures included coronary artery bypass grafting (CABG) (13.6%), thoracic aortic surgery (13.5%), mitral valve surgery (2.1%) and tricuspid annuloplasty (1.6%). Median aortic cross-clamp time was 60 [43–82] min and cardiopulmonary bypass time was 87 [65–116] min, 116.6±43.7 min (Table 2).

Table 2. Operative data.

Variables Data
Full sternotomy 50 (26.2)
Ministernotomy 91 (47.6)
Right anterior minithoracotomy 50 (26.2)
Conversion to full sternotomy 2 (1.4)
Perceval 88 (46.1)
Intuity/Intuity Elite 103 (53.9)
Valve malpositioning 1 (0.5)
Associate procedures 61 (31.9)
CABG 26 (13.6)
Mitral valve surgery 4 (2.1)
Tricuspid valve surgery 3 (1.6)
Maze 6 (3.1)
Thoracic aorta surgery 25 (13.5)
Septal myectomy 4 (2.1)
Overall CPB time 87 [65–116]
Overall clamp time 60 [43–82]
Isolated AVR (min)
   CPB time 80 [58–104]
   Clamp time 55 [35.5-72]
Combined AVR (min)
   CPB time 107 [79–141.5]
   Clamp time 69 [54–96.3]

Data present as n (%) and median [IQR]. CABG, coronary artery bypass grafting; AVR, aortic valve replacement; IQR, interquartile range.

Early outcomes

Overall 30-day mortality was 1.6%. Overall rate of stroke was 4.2% (isolated AVR 3.8% and combined procedure 4.9%). Rate of AV block requiring pacemaker and atrial fibrillation were 7.9% and 31.9%, respectively. No cases of endocarditis, thromboembolism, myocardial infarction or structural valve deterioration were reported in the early phase. Median length of stay in the intensive care unit and hospital stay were 2 (IQR 1–4) and 12 [9–16] days, respectively. Other outcomes are reported in Table 3.

Table 3. In-hospital outcomes.

Variables Data
30-day mortality 3 (1.6)
Stroke 8 (4.2)
Low cardiac output
Ventilatory support >72 h 4 (2.1)
New onset atrial fibrillation 53 (31.9)
New AV block requiring PM 15 (7.9)
Aortic regurgitation 19 (9.9)
Mild 12 (6.1)
Moderate 6 (3.3)
Severe 1 (0.6)
Bleeding requiring revision 6 (3.1)
AKI > stage 1 6 (3.1)
Dialysis
Wound complications 7 (4.5)
ICU stay (days) 2 [1–4]
Hospital stay (days) 12 [9–16]

Data present as n (%) and median [IQR]. AV, atrio ventricular; PM, pacemaker; AKI, acute kidney disease; IQR, interquartile range.

Valve implanted

The Intuity valve was implanted in 53.9% of cases, whereas the Perceval was implanted in 46.1%. One case of Perceval valve malpositioning was reported, which required a second cross clamp and the same Perceval was repositioned. The most common size implanted for Perceval was large (36.3%), followed by medium (29.5%), extra large (26.1%) and small (7.9%). For Intuity, the most common size implanted was 23 (32%), followed by 25 (25.2%), 27 (17.5%), 21 (13.6%) and 19 (11.6%) (Table 4). Overall rate of pacemaker implantation was 7.9% and was slightly higher in the Intuity group (9.7% vs. 5.7%, P=0.446). Overall rate of aortic regurgitation (AR) was 9.9% and similar between groups (Table 5). Rate of moderate and severe AR was 3.7%

Table 4. Valve prostheses: sizes and hemodynamics (n=191).

Peak gradient (mmHg), (mean ± SD) Mean gradient (mmHg), (mean ± SD)
Perceval 28.3±10.9 14.8±5.8
   Small 35.4±8.8 18.5±3.9
   Medium 32.6±9.2 16.7±4.9
   Large 26.8±12.9 14.4±6.9
   Extra-large 22.6±6.1 11.5±3.6
EDWARDS INTUITY/INTUITY Elite 19.2±7 10.9±4.4
   19 mm 23.9±8.4 14.1±5.2
   21 mm 20.6±10.8 12.3±6.4
   23 mm 18.4±5.5 10.4±3.4
   25 mm 18.4±5.5 9.5±3.1
   27 mm 17.1±4.8 9.7±3.4

Table 5. Rate of pacemaker implantation and aortic regurgitation.

Variables Pacemaker implantation Overall AR Mild AR Moderate AR Severe AR
Perceval (n=88) 5 (5.7%) 8 (9.1%) 6 (6.8%) 2 (2.3%)
   Small (n=7) 0 1 (1.1%) 1 (1.1%)
   Medium (n=26) 1 (1.1%) 3 (3.4%) 2 (2.3%) 1 (1.1%)
   Large (n=32) 3 (3.4%) 4 (4.5%) 3 (3.4%) 1 (1.1%)
   Extra-large (n=23) 1 (1.1%) 1 (1.1%)
EDWARS INTUITY/INTUITY Elite (n=103) 10 (9.7%) 11 (10.7%) 6 (5.8%) 4 (3.9%) 1 (1.0%)
   19 mm (n=12) 0 5 (4.9%) 3 (2.9%) 2 (1.9%)
   21 mm (n=14) 2 (1.9%) 0
   23 mm (n=33) 1 (1.0%) 1 (1.0%) 1 (1.0%)
   25 mm (n=26) 5 (4.9%) 3 (2.9%) 1 (1.0%) 1 (1.0%) 1 (1.0%)
   27 mm (n=18) 2 (1.9%) 2 (1.9%) 1 (1.0%) 1 (1.0%)

AR, aortic regurgitation.

Discussion

Our study demonstrated that in patients with BAV disease, AVR with either sutureless or rapid deployment valves is a safe procedure, associated with excellent outcomes and hemodynamic performances. Specifically, overall 30-day mortality was 1.6%, which reflected the predicted median Euroscore II. Furthermore, no cases of endocarditis, thromboembolism, myocardial infarction or structural valve deterioration were reported in the early phase. Interestingly, the majority of these procedures were performed through a minimally invasive approach, reinforcing the concept that SURD valves are not contraindicated in BAV. We reported only one case of valve migration (Perceval) which required a second cross clamp for repositioning the same valve. This is the largest case series study reporting outcomes of patients with BAV undergoing AVR with the Perceval or Intuity valve. These valves have been developed as an alternative to conventional, stented valves to reduce operative times and standardize the surgical procedure (3-7). Outcomes are excellent up to 10 years; however, these results focused mainly on patients presenting with tricuspid aortic valve (3,6,13). BAV has been considered a contraindication for the implantation of the SURD valve, as it is often associated with altered geometric root, sinus asymmetry, elliptic annulus and different commissural heights. In addition, some cases of migration and dislocation have been reported at follow-up, suggesting some words of caution in using these prostheses in BAV (11,12,14). An international expert consensus panel recommends the use of CT scan in defining the anatomical root geometry for evaluating aortic annulus, sinotubular junction and leaflet morphology (15). In the presence of BAV, experts recommend the use of SURD valves in type 1 Sievers classification as well as in some cases of type 2 when the two commissures have approximately the same height. Conversely, the absence of raphe (type 0) is considered an absolute contraindication, because of its anatomy related to asymmetric height of commissures, unequal width of the sinuses of Valsalva and 180° orientation of the coronary ostia.

Nguyen et al. reported the first case series of 25 type I BAV patients and aortic stenosis receiving the Perceval valve (8). Interestingly, neither migration nor structural damage occurred at follow-up and only 3 patients had trace of AR. The key points for a perfect sealing of SURD valves are the symmetry of the aortic annulus and the equality of the heights of the leaflet commissures. Nguyen et al. suggested recreating the 3 nadir points positioned at 120 degrees as it is in a tricuspid valve. However, this technique is suitable only in type I BAV when 3 equal commissures and sinus of Valsalva are present. In all other cases, a commissural plication is required to restore the circularity of the aortic annulus, especially when commissures are placed at different heights (10). Based on this technical consideration, Durdu et al. reported 13 successful cases of AVR through minithoracotomy with Perceval in BAV, of whom 4 had type 0 and 2 type 2 BAV (9). In addition to the intercommissural triangle plication for annular remodeling, authors recommended a thorough decalcification of the aortic annulus as it restores its elasticity and adaptability to the implanted prosthesis. We finally add that the correct sizing is essential in avoiding postoperative AR and pacemaker implantation. The choice of a smaller valve may be associated with paravalvular leakage for the Intuity valve and central AR for the Perceval. Conversely, a larger valve might be associated with increased pacemaker implantation rate for both valves and potential hemodynamic turbulence in the case of the Perceval valve.

Rate of postoperative stroke was higher compared to other studies involving SURD and that deserves some potential explanation. BAV is often heavily calcified and its debridement to restore the annular circularity may have contributed this result. Furthermore, one patient had a previous stroke. Finally, this rate was higher in combined procedures (3.8% vs. 4.9%). It is well known that combined procedures are associated with a higher complication risk (16,17).

The rate of significant postoperative AR was 3.7%. This data is in the line with others. However, when compared with the overall population of SURD registry, we found 2.5 times the increased risk of postoperative AR, highlighting the complexity of BAV anatomy and the importance of restoring the annular circumference for a perfect result (5).

The incidence of pacemaker (PMK) implantation was 7.9% (15 patients). Several mechanisms may be associated with PMK implantation, the most common contributing factor being mechanical trauma related to decalcification and the expansion of both valves at the level of left ventricular outflow tract. However, extensive debridement of the aortic annulus and center timing policy for PMK implantation may have also contributed (18). Finally, the absolute number of pacemaker implantations was low, therefore we were not able to evaluate a potential improvement of this rate over the years.

This study presents several limitations. First, it is based on the retrospective analysis of the SURD international registry. Therefore, we were unable to account for influence of any residual unmeasured factors that could affect the adverse outcomes. Second, our database does not account for the Sievers classification and it is not possible to investigate between BAV type and AR. Then, our database was not able to distinguish paravalvular leak or central regurgitation. Finally, no follow-up is available and therefore we do not know about any potential cases of dislocation/migration.

In conclusion, BAV itself is not a contraindication for implantation of SURD valve. However, a word of caution is required. Even though we dealt with any type of BAV, AVR with SURD in type 0 BAV is technically demanding. Detailed information of aortic root geometry as well as the knowledge of some technical considerations—decalcification, sizing, and annular remodeling—are mandatory for a good outcome.

Acknowledgments

None.

Ethical Statement: Ethics approval was obtained at each of the participating centers, and datasets were submitted according to predefined spreadsheet format.

Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0/.

Footnotes

Conflicts of Interest: Antonio Miceli: Livanova consultant; Martin Andreas is a proctor for Edwards Lifesciences and Advisory Board Member for Medtronic, Inc.; Gianluca Martinelli: proctoring and speakers services for Edwards; Carmelo Mignosa is a consultant/proctor for LivaNova; Alberto Albertini receives consulting and lecture fees from LivaNova; Marco Solinas: Livanova consultant; Mattia Glauber: Livanova consultant; Theodor Fischlein: LivaNova and BioStable consultant; Bart Mauris: Livanova and Edwards Consultant. The other authors have no conflicts of interest to declare.

References

  • 1.Sievers HH, Schmidtke C. A classification system for the bicuspid aortic valve from 304 surgical specimens. J Thorac Cardiovasc Surg 2007;133:1226-33. 10.1016/j.jtcvs.2007.01.039 [DOI] [PubMed] [Google Scholar]
  • 2.Michelena HI, Prakash SK, Della Corte A, et al. Bicuspid aortic valve: identifying knowledge gaps and rising to the challenge from the International Bicuspid Aortic Valve Consortium (BAVCon). Circulation 2014;129:2691-704. 10.1161/CIRCULATIONAHA.113.007851 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Shrestha M, Fischlein T, Meuris B, et al. European multicentre experience with the sutureless Perceval valve: clinical and haemodynamic outcomes up to 5 years in over 700 patients. Eur J Cardiothorac Surg 2016;49:234-41. 10.1093/ejcts/ezv040 [DOI] [PubMed] [Google Scholar]
  • 4.Powell R, Pelletier MP, Chu MWA, et al. The Perceval Sutureless Aortic Valve: Review of Outcomes, Complications, and Future Direction. Innovations (Phila) 2017;12:155-73. 10.1097/imi.0000000000000372 [DOI] [PubMed] [Google Scholar]
  • 5.Di Eusanio M, Phan K, Berretta P, et al. Sutureless and Rapid-Deployment Aortic Valve Replacement International Registry (SURD-IR): early results from 3343 patients. Eur J Cardiothorac Surg 2018;54:768-73. 10.1093/ejcts/ezy132 [DOI] [PubMed] [Google Scholar]
  • 6.Laufer G, Haverich A, Andreas M, et al. Long-term outcomes of a rapid deployment aortic valve: data up to 5 years. Eur J Cardiothorac Surg 2017;52:281-7. 10.1093/ejcts/ezx103 [DOI] [PubMed] [Google Scholar]
  • 7.Phan K, Tsai YC, Niranjan N, et al. Sutureless aortic valve replacement: a systematic review and meta-analysis. Ann Cardiothorac Surg 2015;4:100-11. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Nguyen A, Fortin W, Mazine A, et al. Feasibility and outcomes of sutureless valve replacement in patients with bicuspid aortic valves. J Thorac Cardiovasc Surg 2015;150:851-7. 10.1016/j.jtcvs.2015.05.071 [DOI] [PubMed] [Google Scholar]
  • 9.Durdu MS, Gumus F, Ozcinar E, et al. Sutureless Valve Replacement Through a Right Anterior Mini-thoracotomy in Elderly Patients With Stenotic Bicuspid Aortic Valve. Semin Thorac Cardiovasc Surg 2019;31:458-64. 10.1053/j.semtcvs.2018.09.025 [DOI] [PubMed] [Google Scholar]
  • 10.Glauber M, Ferrarini M, Lio A, et al. Dealing with a stenotic bicuspid aortic valve: Is this still an off-label procedure for a sutureless valve? J Thorac Cardiovasc Surg 2015;150:858-9. 10.1016/j.jtcvs.2015.07.049 [DOI] [PubMed] [Google Scholar]
  • 11.Chiariello GA, Villa E, Messina A, et al. Dislocation of a sutureless prosthesis after type I bicuspid aortic valve replacement. J Thorac Cardiovasc Surg 2018;156:e87-9. 10.1016/j.jtcvs.2018.02.002 [DOI] [PubMed] [Google Scholar]
  • 12.Amir A, Moore A, Carvalho G, et al. A story of migration of a surgically implanted aortic sutureless. J Cardiothorac Vasc Anesth 2018;32:464-6. 10.1053/j.jvca.2017.06.038 [DOI] [PubMed] [Google Scholar]
  • 13.Meuris B, Szecel D, Eurlings R, et al. Sutureless AVR experience in a single center:11 years of use in 468 patients. Presented at 99th AATS meeting 2019 Toronto, Canada. [Google Scholar]
  • 14.Carrier M. Replacement of bicuspid aortic valve with sutureless bioprosthesis: a word of caution here. J Thorac Cardiovasc Surg 2018;156:e91. 10.1016/j.jtcvs.2018.02.043 [DOI] [PubMed] [Google Scholar]
  • 15.Gersak B, Fischlein T, Folliguet TA, et al. Sutureless, rapid deployment valves and stented bioprosthesis in aortic valve replacement: recommendations of an International Expert Consensus Panel. Eur J Cardiothorac Surg 2016;49:709-18. 10.1093/ejcts/ezv369 [DOI] [PubMed] [Google Scholar]
  • 16.Messé SR, Acker MA, Kasner SE, et al. Stroke after aortic valve surgery: results from a prospective cohort. Circulation 2014;129:2253-61. 10.1161/CIRCULATIONAHA.113.005084 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Online STS Adult Cardiac Surgery Risk Calculator. Accessed on 26 February 2020. Available online: http://riskcalc.sts.org/stswebriskcalc/calculate
  • 18.Miceli A, Lio A, Glauber M. Size, position, and timing: A mixture of success. J Thorac Cardiovasc Surg 2016;152:633-4. 10.1016/j.jtcvs.2016.03.034 [DOI] [PubMed] [Google Scholar]

Articles from Annals of Cardiothoracic Surgery are provided here courtesy of AME Publications

RESOURCES