How best to interpret measures of levels of oxygen in tissues to make them effective clinical tools for care of patients with cancer and other oxygen‐dependent pathologies

Harold M Swartz 1,2,3, Ann Barry Flood 1,, Philip E Schaner 2, Howard Halpern 4, Benjamin B Williams 1,2,3, Brian W Pogue 3,5, Bernard Gallez 6, Peter Vaupel 7,8
PMCID: PMC7422807  PMID: 32786045

Abstract

It is well understood that the level of molecular oxygen (O2) in tissue is a very important factor impacting both physiology and pathological processes as well as responsiveness to some treatments. Data on O2 in tissue could be effectively utilized to enhance precision medicine. However, the nature of the data that can be obtained using existing clinically applicable techniques is often misunderstood, and this can confound the effective use of the information. Attempts to make clinical measurements of O2 in tissues will inevitably provide data that are aggregated over time and space and therefore will not fully represent the inherent heterogeneity of O2 in tissues. Additionally, the nature of existing techniques to measure O2 may result in uneven sampling of the volume of interest and therefore may not provide accurate information on the “average” O2 in the measured volume. By recognizing the potential limitations of the O2 measurements, one can focus on the important and useful information that can be obtained from these techniques. The most valuable clinical characterizations of oxygen are likely to be derived from a series of measurements that provide data about factors that can change levels of O2, which then can be exploited both diagnostically and therapeutically. The clinical utility of such data ultimately needs to be verified by careful studies of outcomes related to the measured changes in levels of O2.

Keywords: clinical measures of oxygen, oxygen in tissues, partial pressure

1. INTRODUCTION

The overall goal of this review is to facilitate clinically effective use of measurements of molecular oxygen (O2) in tissues with the explicit intent of improving clinical care, that is, improving the accuracy and effectiveness of diagnoses, treatments, and prognoses for individual patients. This review focusses especially on improving personalized medicine and outcomes of care, by carefully considering the basis and validity of clinical measurements of O2 in tissues and how those measurements can be used to advance diagnosis and therapy. While measurements of O2 in tissues have been recognized as an important factor in the clinical evaluation and treatment of many diseases, especially cancer (Busk, Overgaard, & Horsman, 2020), and pathologies involving ischemia (such as in peripheral vascular disease and wound healing), insufficient attention often has been paid to the meaning of the values that have been obtained. (Note: this review is derived, in part, from a series of recent papers on this topic; Flood et al., 2020; Swartz, Flood, et al., 2020; Swartz, Vaupel, et al., 2020.)

Instead, all too often, when a measurement technique has indicated that the level of O2 in a given tissue is “X,” that is, is some specific quantitative number for the O2 in the tissue, researchers, and clinicians alike assume that “X” is a reliable, accurate representation of the “true” oxygenation status of the tissue. This approach ignores the complexity and dynamics of O2 in living biological systems. The reality is that any O2 measurement has been taken at only one point in time of a distribution in the subvolume that was interrogated by the method, while the O2 is in fact varying with time and across space in the tissue and is unlikely to be uniform in the volume that is being interrogated.

In this review we focus on the biological/clinical meaningfulness of O2 measurements made in living organisms, while recognizing that tissue O2 is in constant flux. We emphasize that, to obtain maximum clinical utility of the measurements, it is necessary to consider the goal of the measurements and the limitations of the data that are obtained. We particularly focus on the clinical value of making repeated measurements of O2, especially in association with strategies/events that potentially change O2 levels.

2. WHAT ARE OXYGEN LEVELS IN TISSUES?

2.1. Physical concepts and terminology for reporting on oxygen levels in tissues

The level of molecular oxygen, that is, O2, is usually reported as partial pressure of oxygen (pO2) or concentration of oxygen ([O2] or cO2). These terms have physically rigorous meanings that can usefully be extended to describe gases (such as O2) that are dissolved in liquids or solids, including tissues. Partial pressure is the pressure exerted by oxygen in a mixture of gases, while concentration is the content of oxygen in the gas mixture or solid. Partial pressure is commonly expressed in mmHg, and these units are sometimes referred to as torr or kPa (SI unit used in the EU), while concentration of O2 is commonly expressed in mL of O2 per 100 ml, for example, in blood.

However, the solubility of oxygen varies greatly in different media (Bennett, Swartz, Brown, & Koenig, 1987; Jordan et al., 2013) and this affects the relationship between pO2 and [O2]. The transport of O2 across lipid membranes is known to depend on both diffusion and solubility in the bilayer, and to be affected by changes in the physical state and by the lipid composition, especially the content of cholesterol and unsaturated fatty acids. For example, because O2 partitions preferentially into lipophilic media, such as membranes, the solubility of O2 in membranes is about four times greater than in aqueous solutions (Möller et al., 2016). This difference has significant consequences for physical and chemical interactions involving molecular oxygen in biological systems because these interactions depend on the number of oxygen molecules that are present and their rate of diffusion.

Does it matter clinically to know whether the technique is reporting [O2] or pO2? While these measures are not identical, there is a known relationship between them. According to the ideal gas law, pO2 is directly proportional to concentration, assuming the volume and temperature are constant, that is,

PV=nRT

where P = pressure (pO2); V = volume; N = amount of substance [O2]; R = ideal gas constant; T = temperature.

It is less straightforward in biological systems. If the solubility of oxygen in each component of tissue is known (and this is not always fairly readily derived experimentally) and pO2 can be measured, then it is relatively straightforward to calculate [O2]. Conversely, if the component in which [O2] is measured and the solubility of O2 in that compartment is sufficiently known, then it should be feasible to determine pO2. However, it often is not feasible to measure these parameters readily.

Because of the biological complexities in assessing O2 in tissues, each reported measure of O2 level in a tissue can be better considered as an average value. Average is used here in its more colloquial usage rather than as a statistically defined term, because different techniques output their measurement of O2 using differing methods pertinent to that technique. Each technique gathers information from a particular volume of tissue (irrespective of whether that volume is well characterized), which we refer to hereafter as the “interrogated volume.” The sampling of data within the interrogated volume is then used to produce a measure based on a sort of average O2 within that volume. Characterizing that “average measure” is made difficult both by the imprecision of knowing the exact volume queried, but also because the detection of O2 in that volume may be affected by factors such as its distance from the detector or, for optical techniques, different rates of scattering (that also may not be well characterized). Hence, we conclude that it is important to bear in mind that the measurements of O2 in vivo are fundamentally based on a sort of “average” within the interrogated volume.

Because of all of these challenges in obtaining precise measurements of relevant parameters necessary to assess whether the data obtained by any technique is truly measuring either pO2 or [O2] and because of the imprecisions of knowing the volume being assessed and the tissues within that volume, it is more realistic to acknowledge the complexity of these issues for in vivo measurements in tissues by using a less precise term for measures of molecular oxygen in tissues such as “O2 levels,” which is the convention we follow in this review. We also argue that, while it is important to recognize the biological imprecisions in these measures, there are still many clinically viable uses of this information (such as assessing change in O2 levels).

Note too, within this paper, while focusing on the uncertainties due to sampling issues of each technique and variations due to biological factors, we are not taking into consideration further uncertainties due to inevitable instrumental noise, variations in the placement of the detector, etc.

2.2. Expected levels of O2 in tissues

Table 1 presents some illustrative data on the O2 levels in various tissues, both in normal states and as altered by some diseases. (These measures are presented here as reported in the literature.) The first column presents the median pO2 obtained, using the Eppendorf electrode (or comparable polarographic techniques) to measure O2 levels in patients; also presented are two other indications of O2 levels: the hypoxic fraction (the percentage of measurements in a given type of tissue that is below a defined “hypoxic level,” in this case 2.5 mmHg) and the range of pO2 values found experimentally. These data illustrate both the variation in median O2 levels between types of tissues and how they may vary with physiology or disease. For example, (intertissue) in general the median O2 levels are lower in skeletal muscle and heart compared to the spleen; (intratissue) the median O2 in skeletal muscle at rest is higher than with exercise while, in contrast, there is almost no variation between the normal spleen and with Hodgkin's disease. The data in Column 4 illustrate the wide range that any given measurement can have in the “same” type of tissue, that is, almost all tissues range from ~0 to ~100 mmHg, even when their median value is quite different (see again spleen vs. bone). However, these very high values in the upper range may include experimental artifacts due to the measurement being taken within or very close to an arteriole, for example, a vessel feeding the microcirculatory bed.

Table 1.

Oxygenation status of organs/tissues

Organ/tissue Median pO2 (mmHg) HF 2.5 (%) pO2 range (mmHg) References
Kidney
Cortex 45–50 1–2 1–97# Günther, Aumüller, Kunke, Vaupel, and Thews (1974)
Outer medulla 38 2–5 2–96 Same
Inner medulla 11 9–11 0–32 Same
Liver 25–30 1–2 1–96 Kallinowski and Buhr (1995a)
Pancreas 57 2 1–95 Koong et al. (2000)
Spleen
Normal 68 1–2 2–96 Vaupel, Wendling, Thomé, and Fischer (1977)
In hypersplenism 69 2 2–97 Wendling, Vaupel, Fischer, and Brünner (1977)
Hodgkin's disease 67 2 2–96 Same
Myocardium
Subepicardial 18–26 1 1–96 Winbury, Howe, and Weiss (1971)
Subendocardial 10–17 n.a. 1–94 Moss (1968) (for both)
Mucosa
Oral 52 1 1–96 Kallinowski and Buhr (1995a)
Rectal 51 n.a. 1–95 Same
Large bowel 55 n.a. 1–95 Same
Breast
Normal 65 0 10–96 Vaupel, Schlenger, Knoop, and Höckel (1991), Vaupel and Harrison (2004)
Fibrocystic disease 67 0 5–98 Same
Prostate 26 4 1–96 Vaupel and Kelleher (2013)
Uterine cervix 41 8 1–97 Höckel, Schlenger, Knoop, and Vaupel (1991)
Subcutis 52 0 0–96 Same
Bone
Cortical 32 3 0–96 Spencer et al. (2014)
Hematopoietic marrow 22 1 0–95 Same
Adipose marrow 26 2 0–95 Same
Skeletal muscle
Resting 27–32 0–2 0–96 Landgraf and Ehrly (1980)
Exercise 10 5–10 0–96 Jung, Kessler, Pindur, Sternitzky, and Franke (1999)
Hypovolemic shock 4 40 0–40 Harrison and Vaupel (2014)
PAOD 6–7 ~30 0–90 Landgraf, Schulte‐Huermann, Vallbracht, and Ehrly (1994)
Skin
Thermoneutral conditions 25–35 n.a. 40–70 Carreau et al. (2011)
Critical limb ischemia 5–8 18 0–96 Harrison and Vaupel (2014)
Limbs, venous disease 15 n.a. 40–65 Clyne, Ramsden, Chant, and Webster (1985)
Brain
Gray matter 28 1 1–96 Vaupel (1994)
White matter 10–15 n.a. n.a. Same
Retina ~20 n.a. 0–70 Hogeboom van Buggenum, van der Heijde, Tangelder, and Reichert‐Thoen (1996), Linsenmeier and Zhang (2017)
White adipose tissue
Nonobese 56 n.a. 40–74 Pasarica et al. (2009), Hodson (2014)
Obese 47 n.a. 29–63 Lempesis, van Meijel, Manolopoulos, and Goossens (2020)

Abbreviations: #: arterial; HF2.5: hypoxic fraction ≡ fraction of pO2 values ≤2.5 mmHg; n.a.: information not available; PAOD: peripheral arterial occlusive disease.

Table 2 presents the same types of information for a more detailed analysis of changes in an important pathology, cancer, where O2 levels have been an especially important focus for informing clinical treatment and prognosis. To give the reader a sense of how well supported the numbers are, the data in Table 2 have been ordered by the number of patients included in each row.

Table 2.

Pretherapeutic oxygenation status of human tumors

Tumor type (ordered by no. of patients) No. of patients Median pO2 (mmHg) HF 2.5 (%) pO2 range (mmHg) References
Cervix cancer 730 9–10 28 0–88 Vaupel et al. (2007)
Head and neck cancer 592 10 21 0–90 Vaupel (2009)
Prostate cancer 438 7 26 0–95 Vaupel (2011)
Soft tissue sarcoma 283 14 13 0–96 (data synopses)
Breast cancer 212 10 30 0–95 These 3 ref. apply to all
Glioblastoma 104 13 26 0–50 Above the line
Vulvar cancer 54 11 25 0–92 Vaupel, Thews, Mayer, Höckel, and Höckel (2002), Vaupel, Mayer, and Höckel (2006), Stone et al. (2005)
Rectal cancer 29 25 n.a. 0–92 Kallinowski and Buhr (1995a), Mattern, Kallinowski, Herfarth, and Volm (1996)
Lung cancer 26 16 13 0–95 Falk, Ward, and Bleehen (1992), Le et al. (2006)
Malignant melanoma (metastatic) 18 12 5 0–96 Lartigau et al. (1997)
Non‐Hodgkin's lymphoma 8 18 36 0–92 Powell et al. (1999)
Pancreas cancer 8 2 59 0–91 Koong et al. (2000), Graffman, Bjork, Ederoth, and Ihse (2001)
Brain metastases 5 10 26 0–87 Rampling, Cruickshank, Lewis, Fitzsimmons, and Workman (1994)
Liver metastases 4 6 n.a. 0–90 Kallinowski and Buhr (1995a, 1995b)
Renal cell carcinoma 3 10 n.a. 0–90 Lawrentschuk et al. (2005)
Gall bladder cancer 1 4 n.a. 0–10 Graffman et al. (2001)
Bile duct cancer 1 8 n.a. 0–15 Graffman et al. (2001)

Abbreviations: HF2.5: hypoxic fraction ≡ fraction of pO2 values ≤2.5 mmHg; n.a.: information not available.

Of interest here, all seven cancer types with at least 50 patients studied have a fairly consistent and fairly hypoxic median O2 level (~10 mmHg). Similarly, all but soft tissue sarcoma have a similar hypoxic fraction, ~25%; (sarcoma appears to be about half that). Glioma appears to be an outlier on the range; glioma had no patient whose O2 level was above 50 while all others (as was true for the tissues in Table 1) have at least one measurement in the upper 80s or 90s. These occasional high readings are not surprising since it is plausible that, randomly, some readings will have been obtained in or very near to arterioles/feeding microvessels. In contrast to the first seven cancers, the 10 types of cancers with fewer than 30 patients appear to be more varied in their O2 levels, but this is possibly due to being based on few patients.

Nevertheless, even though (as noted elsewhere in this review), the data presented are not unconditionally “absolute values” of O2 levels (as they are sometimes referred to; e.g., Koch, 2002; Macnab, Gagnon, Gagnon, Minchinton, & Fry, 2003). Nevertheless (as argued in this review), they can provide very useful data as long as their limitations are recognized by researchers and clinicians.

3. HETEROGENEITY OF DISTRIBUTIONS OF LEVELS OF OXYGEN IN TISSUES: EXAMPLES AND CAUSES

Heterogeneity of distributions of oxygen values in the tissues of interest exists over many dimensions, including time and space, and over a wide range of scales (Harrison & Vaupel, 2014). Tables 1 and 2 focus on intertissue and intratissue variation in overall levels of O2. Figures 1 and 2 illustrate heterogeneity using more refined data points to illustrate the skewed nature of the data, particularly for malignancies. The data in Figure 1 are based on multiple measurements made in a series of patients using a computerized polarographic microsensor technique which enables direct assessment of the O2 levels with an O2‐sensitive needle electrode (subject to the limitations of providing true absolute values as discussed elsewhere in the paper). Oxygen was measured along several electrode tracks in each individual during a given measurement session (from near the tumor surface up to tissue depths of ~ 30 mm in breast cancers and in cancers of the uterine cervix). Each row in Figure 1 presents a type of tissue (breast and uterine cervix) with comparisons of O2 levels made in normal tissue (green) versus malignancies (prior to treatment) of these organs (red). The summary measures, median pO2 values (parallel to data reported in Tables 1 and 2), are included in the text boxes.

Figure 1.

Figure 1

Distributions of multiple O2 levels made in patients with normal versus malignant tissue: Breast and cervix. (Figure adapted from Vaupel & Mayer, 2017b, p. 3,343)

Figure 2.

Figure 2

Repeated O2 level measurementsA during each measurement session and over 42 days: Breast cancer patient measured in skin and superficial breast tissue within the radiation field during a course of radiation therapy. (Figure adapted from Flood et al., 2020, p. 164.) AFor Carlo Erba ink, EPR line width increases with increasing O2 level, but the relationship is nonlinear and can be impacted by several factors. Therefore, the data are given here as line width

Note that the data in Figure 1 are not normally distributed; (the distribution of O2 levels made in normal breast tissue is the closest approximation to a normal distribution). Comparing the two distributions for malignancies, we see that breast cancer is more highly skewed than cervical cancer, although they have the same median. Thus, using a single measure such as the median could overlook potentially important clinical information.

Similarly, comparing the distributions for the normal tissues, the normal cervix had a substantial number of O2 measurements within a hypoxic range defined as ≤10 mmHg, while there were no hypoxic measurements in the normal breast. While Figure 1 does not differentiate the measurements made per patient, it illustrates why several authors report the hypoxic fraction when trying to capture a meaningful overall number to characterize a tissue. Finally, these data underscore why it is important to understand what is well captured by a given measure of O2 level—and what is missed or obscured.

Another example of heterogeneity is presented in Figure 2. These O2 measurements were taken in a breast cancer patient using EPR oximetry with Carlo Erba ink as the O2 sensor (Flood et al., 2020; Jeong et al., 2019). The data are presented as line widths, because the EPR oximetry technique using India Ink as a sensor undoubtably gathers data from volumes too large to have homogenous oxygen levels; however, because this sensor remains in the same place in the tissue, it still can provide very useful indications of changes over time and/or the impact of interventions such as breathing enriched oxygen. The data were taken in 30‐min sessions, during which EPR spectra were collected continuously, but the period was divided into three 10‐min periods, differing by the gas mixture the patient was breathing: room air (red: baseline), 100% O2 delivered by a nonrebreather mask (green), followed by again breathing room air (blue: recovery). The sessions were repeated approximately weekly throughout the period of radiation therapy (thus mimicking a clinical course of radiation therapy, although there was no attempt to impact therapy in this study).

The data for this particular patient illustrate that the O2 levels responded to the patient's breathing an hyperoxic gas mixture and then returned rapidly to the baseline level after the 10‐min period. In this patient, there appeared to be some variation across the weeks of treatment, with the final levels for each period (baseline, 100% O2, and recovery) all being slightly higher than at the beginning of radiation therapy (based on nonoverlapping standard deviations of the first and last measurements).

3.1. Causes of heterogeneity in normal tissues

There are spatial variances in oxygen levels in normal tissues due to the longitudinal gradient in oxygen as the blood passes through the microcirculatory bed (decreasing from the arterial inlet to the outlet of the microvessels; Erickson et al., 2003). After the oxygen leaves the microvascular networks, the partial pressure of O2 decreases due to radial gradients, that is, O2 diffuses through the tissues as it gets further from the vessels, due to O2 being consumed by the cells. As a result, there are variations in O2 levels from cell to cell (according to their distance from the microvessel). Within the cells O2 decreases in a microspatially complex manner as it is intracellularly consumed, with most of the consumption occurring in the mitochondria. There is growing evidence that diffusion of O2 into the cell may be constrained, that is, that O2 does not freely and rapidly flow into cells across the membrane, and therefore there are gradients from outside to inside of cells (Khan et al., 2003; Kurokawa et al., 2015; Pias, 2020).

These variations of O2 levels, that is, gradients between and within cells, cannot currently be measured. As detailed below in discussing temporal variations, even if such measurements of spatial heterogeneity could be made, they would still be inadequate to understand the full complexity of heterogeneity of O2. For example, in some normal tissues, there is additional significant macroscopic heterogeneity of O2 over space because of their physiology as a consequence of substantial differences in vascularity, blood flow, and oxygen consumption (e.g., macroscopic heterogeneity between gray and white matter of the brain, between subepicardial and subendocardial layers of the myocardium, and between renal cortex and renal inner medulla).

There also are temporal changes in O2 levels in normal tissues (Griffith, 1996). Moreover, the supply of O2 can vary periodically due to rhythmic changes in microcirculatory blood flow which is reflected at all levels from the inflow arteries to the microcirculation. Finally, within the microcirculation there are variations in microvascular flow due to regional regulation in response to varying metabolic demands (Kimura et al., 1996). Important differences in O2 solubility across tissues, affecting the relationship between pO2 and [O2], were discussed earlier.

3.2. Impact of pathology on heterogeneity of O2 levels

The presence of pathology often significantly increases the amount and extent of oxygen heterogeneity both spatially and temporally (Vaupel & Harrison, 2004; Vaupel & Mayer, 2016). The presence of pathology often impacts the structure/morphology of the vessels. In tumors there often is a significant amount of neoangiogenesis which results in much less ordered and less functional blood vessels (Busk et al., 2020). The resulting vessels are much less efficient in delivering blood and also tend to be much more prone to leak. Leakage from these vessels can cause increases in the interstitial pressure, which can reduce the effectiveness of the microcirculation due to reduction of the perfusion pressure within the tumor capillaries (Fukumura, Duda, Munn, & Jain, 2010).

Pathological changes also can result in altered consumption of O2. In malignant tumors O2 consumption is likely to decrease due to poor oxygen delivery and/or because of a switch to glycolysis due to metabolic reprogramming (i.e., the Warburg effect) as a consequence of HIF‐1α overexpression, upregulation of oncogenes, downregulation of suppressor genes, and activation of certain signaling pathways (Vaupel & Multhoff, 2020; Vaupel, Schmidberger, & Mayer, 2019). Pathology can also impact the integrity of the blood vessels. For example, tumor growth may physically impinge on the integrity of the blood vessels, and the metabolic abnormalities in diabetes can impact the structure of blood vessels (causing either microangiopathy and/or macroangiopathy). The results of these processes can produce very significant local variations in the availability of fully functional vascular structures, resulting in locally hypoxic regions.

Pathology also can impact temporal changes of oxygen and the response to treatment. The presence of pathology, especially cancer (e.g., acute and cycling hypoxia in cancers) and peripheral vascular disease, can result in significantly greater variability in O2 levels (Braun, Lanzen, & Dewhirst, 1999). These include short‐term changes, especially associated with the structural abnormalities of the microcirculation resulting in increased local variability in flow, and long‐term changes that develop over time, such as those due to disease progression and responses to therapy (Baudelet et al., 2004; Kimura et al., 1996; Konerding, Fait, & Gaumann, 2001; Matsumoto et al., 2006).

There also is a potential for pathologies to interrelate with each other. For example, anemic hypoxia can develop in tumors due to the underlying systemic anemia of the patient (Vaupel & Mayer, 2014).

In addition to these underlying effects of pathology on tissue oxygen levels, any applied therapeutic interventions are very likely to induce changes. For example, cell killing due to radiation or chemotherapy will alter oxygen consumption patterns. These same therapies will also affect the O2 supplying vasculature via both antiangiogenic effects and—possibly—normalization of vessel structure (Jain, 2005). The effects of therapies will generally vary both spatially and temporally, reiterating the complexity of meaningfully characterizing tissue oxygen levels.

4. ANALYSIS OF THE ABILITY OF CLINICALLY AVAILABLE TECHNIQUES TO DIRECTLY MEASURE LEVELS OF O2 IN TISSUES AND/OR RESOLVE THE HETEROGENEITY OF O2 DISTRIBUTIONS IN TISSUES

Although many techniques are often thought to measure actual O2 in tissues, only a few actually have the potential to make O2 measurements directly in the tissues of interest (Springett & Swartz, 2007; Tatum et al., 2006). Techniques that can potentially assess O2 directly in tissues include: EPR (Epel et al., 2019; Swartz et al., 2014; Swartz et al., 2014), the Eppendorf electrode (Vaupel, Höckel, & Mayer, 2007), some optical methods based on direct measurements of target molecules in tissues, for example, phosphorescence quenching of optical sensors placed directly in tissues or as part of a physical probe such as the “OxyLite” (Wen et al., 2008), and NMR relaxation techniques (Colliez et al., 2014).

Two other types of measurements assess O2 in the vascular system. Blood gases do this directly, while optical methods that measure both hemoglobin saturation and total hemoglobin (especially near infrared spectroscopy [NIRS]; Scheeren, Schober, & Schwarte, 2012) provide a plausible link to the pO2 in the blood.

However, the techniques most often used clinically to characterize tissue oxygenation do not in fact measure O2 directly; instead, they measure “indirect” parameters that can be plausibly linked to actual O2 levels but only under appropriate/defined circumstances. This latter group of techniques includes positron emission tomography (PET) imaging of glucose derivatives (Neveu et al., 2015), PET imaging of drugs that localize in hypoxic tissues (Tran et al., 2012), laser Doppler flow, measures of metabolites that may be affected by O2 levels, for example, lactate and redox intermediates, and several magnetic resonance imaging/nuclear magnetic resonance (MRI/NMR), blood oxygenation level dependent (BOLD) imaging (Baudelet & Gallez, 2002), and MRI (Egeland et al., 2006). Note: If their basis is understood and the data considered accordingly, these can all provide clinically and physiologically useful information even though they do not provide direct information on the amount of O2 in the tissues.

4.1. Direct measures of O2 in targeted tissues that potentially can be used in human subjects

These are techniques that, while they have the capability of providing direct quantitative measurements of O2 in homogeneous media, cannot provide such data in tissues in vivo because the volumes that they sense are larger than the volumes of homogeneity of O2 in actively metabolizing tissues. Consequently, all in vivo measurements of O2 are inherently averages of the actual oxygen content in that volume. Even neglecting the need to include measures of heterogeneity inside cells, based on the usual volume of cells and assuming that differences are sought for aggregates of ≤3 cells, for a measurement of heterogeneity sensed within a 10 mm diameter volume, the spatial resolution needed to appropriately characterize O2 levels in this volume becomes 8 million voxels. The measuring techniques may not even provide a well‐defined averaged pO2 value within the volume that they sense. For example, sensors for the signal that is being measured.

In the next sections we review the characteristics of each technique that can directly measure O2 levels in tissues. We also briefly remark on the volumes they measure and how the measures obtained can be useful clinically (see also Ortez‐Prado, Dunn, Vasconez, Castillo, & Visco, 2019).

4.1.1. EPR oximetry

Using appropriate particulate paramagnetic materials, EPR oximetry can provide direct measurements of O2, that is, the EPR signal is directly proportional to the amount of O2 (Epel, Bowman, Mailer, & Halpern, 2014; Swartz, Vaupel, et al., 2020). Because each multisite sensor senses a volume that is much larger than capillary networks, these techniques provide a volume averaged sampling of all compartments within the tissues. The time resolution of the techniques can be milliseconds or shorter.

The measured parameter of an EPR spectrum that indicates the amount of O2 present is the line width of the observed resonance peak. There usually is a fixed relationship between the line width and the amount of O2, with the relationship being specific for each type of paramagnetic material, for example, carbon, charcoal, or phthalocyanine particulates. Using particulate oximetric materials, measurements can be continuous over any span of time and can be repeated indefinitely (see example in Figure 2). The method requires that the sensing material be injected or implanted in one or more regions of interest, but thereafter all measurements can be made entirely noninvasively. Importantly the measurements can be carried out in a clinical setting and can fit into the workflow needed for patient care.

The initial clinical EPR measurements of oxygen in tissues have used India Ink as the oxygen sensor (Swartz et al., 2014). The carbon particles are the components that respond to oxygen (Lan, Beghein, Charlier, & Gallez, 2004). After injection of 30–50 µl of the suspension through a small needle, the carbon particles disperse nonuniformly through the local region as small extracellular aggregates. They are often engulfed by macrophages. The resulting EPR spectra in the region probed by the resonator (i.e., the surface coil used for signal detection) are a composite of the oxygen‐dependent line widths from each of the particles. In reality, because of the relatively broad lines from the India Ink particles, the range of “oxygen levels” that are likely to be present in the tissue, and the limited number of particles in each subregion, it is a challenge to resolve directly even the major groups of similar line widths. Therefore, using the observed line width to provide a quantitative measure of oxygen would seem to have modest utility in itself.

The other method of clinical EPR oximetry is based on the use of micro‐crystalline probes (e.g., LiPc, LiNc‐BuO), encapsulated in biocompatible polymers (Swartz et al., 2014). Clinical measurements currently are being performed using the “OxyChip” which consists of oxygen sensitive microcrystals of lithium octa‐n‐butoxynaphthalocyanine (LiNc‐BuO) embedded in polydimethylsiloxane (PDMS; Hou, Khan, Gohain, Kuppusamy, & Kuppusamy, 2018; Hou et al., 2016; Jarvis et al., 2016). The dimensions currently used in humans are cylinders that are 5 mm long with a diameter of 0.6 mm. The EPR signal from the sensor (OxyChip) reflects the pO2 within the PDMS, which itself reflects an average of the pO2 in contact with the external surface of the cylinder. The dimensions of the OxyChip are much greater than those of a microcirculatory unit and therefore reflect many different such units. The microcirculatory networks sampled by the OxyChip are likely to include regions with quite different O2 levels. The “values” of oxygen that are obtained therefore do not, in themselves, provide any information on the heterogeneity of the sampled capillary networks.

In contrast to EPR spectroscopy based on particulates with stable free radicals, EPR oximetry imaging can provide spatially resolved measurements using soluble paramagnetic materials with stable free radicals, especially nitroxides and trityls (Epel et al., 2014; Epel et al., 2019). An advantage of pulse techniques using spin lattice relaxation rate images of dissolved O2 spin probes is the virtual absence of confounding variation of the spin from the probe affecting the measurement of the effect of O2 on relaxation rates. This is of particular importance for low oxygenation levels where the spin probe concentration and its effect on the relaxation rate approaches that of O2 (Epel et al., 2019). Nonetheless, the volumes of even the smallest resolvable voxel in the images will still be too large to avoid averaging of the O2 levels sensed within each voxel. The time resolution is usually at least several minutes. This technique cannot provide repeated measurements without readministering the paramagnetic material each time. At this time, this technique is available only for preclinical use, because there are no FDA‐approved soluble paramagnetic materials.

4.1.2. The Eppendorf electrode

The Eppendorf electrode has been used clinically to provide direct tissue pO2 measurements along electrode tracks. To create a track, a series of points is obtained by progressing the 200 µm microelectrode through the tissue in a sequence of “Pilgrim steps,” that is, the probe is advanced a prescribed distance and then withdrawn a fraction of that distance to minimize pressure effects. The volume sampled by each point is estimated to be 100–500 cells around the tip of the probe (Vaupel et al., 2007). Therefore, the measurement usually reflects the average of a range of pO2 values, especially in the presence of pathophysiology. The histogram of values of a tumor was thought to be a representative sample of three to seven tracks through the volume, although this still was only a sampling of the true heterogeneity of the tissue O2. Nevertheless, in tumors, very useful clinical correlations have been found with the number of points below a threshold value, for example, median pO2 or hypoxic fractions (Vaupel & Mayer, 2007). Note that this does not require individual, true absolute pO2 values. Instead, the separation between severely hypoxic and less hypoxic values relies on averaged oxygen tensions. When used with multiple point measurements (>70), this is a good but not infallible technique to determine the presence of hypoxic regions. Regardless of its potential advantages, unfortunately this technique is no longer available clinically. This technique also had some practical limitations, including difficulties to repeat the measurement in a given tissue subvolume because of the local trauma produced from the preceding measurements.

Currently the only version of the oxygen electrode suitable for use in humans is a technique requiring temporary implantation of an oxygen electrode that extends through the skin and skull and is used to monitor severe brain trauma. Such a device, while very useful for its intended purpose, is not suitable for measurements in tumors (Stewart et al., 2008).

4.1.3. Optical methods

The OxyLite technology is based on quenching by O2 of fluorescence with a sensor whose diameter is 230–750 µm at the end of a fiber‐optic fiber (User Manual, 2020). This cross‐section corresponds to the diameter of a tissue subvolume of 10–75 mammalian cells. And, therefore, the sensor will provide an average of the distribution of pO2 values throughout this volume. The temporal resolution can be quite rapid. It could be used in a manner similar to the Eppendorf electrode to obtain a series of similarly averaged measurements at different locations.

Direct injection of phosphorescent agents can provide one way to directly sample tissue O2, where the signal comes from the phosphorescence lifetime changes that result from excited triplet state quenching of O2 (Wilson, Harrison, & Vinogradov, 2012). High resolution mapping with very fast time resolution can be provided, although care must be taken in choosing the probe that localizes in the compartments of interest, as some provide intracellular information, some provide purely extracellular information, and some are simply perivascular in nature (Esipova et al., 2011). A key part of advancing these molecular probes has been to ensure that they sample the oxygen in the environment with a buffer around them such that the oxygen diffuses into the sensor and any measurement of oxygen by the triplet state quenching does not alter the local oxygen level, making the signal potentially nonlinear. Many unprotected or bare nanoparticle probes can have a signal dependence which is not ideal for linearity with oxygen or repeated measurements, or they could have uncertain localization. Dendrimer particles of the Oxyphor complex have been used as biocompatible large particles with pegylation to the exterior to ensure a known biodistribution (Esipova et al., 2019). Their localization is largely extracellular as well, but of course the localization can be tailored by specifically altering the surface chemistry, and they have been used to create probes for many unique biological environments such as the gut, bone marrow, or brain.

One of the more promising methods for oxygen measurement in vivo has been through delayed phosphorescence from protoporphyrin IX (Mik et al., 2006), which is present in all tissues to some extent, produced in the mitochondria, and can be proactively enhanced by administration of aminolevulinic acid. This molecule has triplet state quenching by oxygen as well, and the reverse intersystem crossing that can occur in the absence of oxygen allows for a delayed fluorescence signal which is uniquely sensitive to the local oxygen environment. This work was pioneered in cardiac tissues by Mik (2013) and shown to be a logical way to sample tissue oxygen (Scholz, Cao, Gunn, Brůža, & Pogue, 2020).

An important aspect of all these optical methods is that the depth of measurement is dominated by the light input/output geometry, which is typically limited to just a millimeter or two of depth for diffuse illumination and detection. Microscopy studies are widespread as they lend themselves well to thin tissues and take advantage of coherence or optical confinement tools. Thicker tissues are less studied, as this regime is more dominated by the tissue scattering nature than the features of the light signals. The development of x‐ray induced Cherenkov‐excited luminescence methods (which concomitantly use a specially developed porphyrin Oxyphor PtG4, developed by David Wilson and Sergei Vinogradov, University of Pennsylvania) have been shown to be useful for imaging through a few centimeters of tissue. This takes advantage of the deeper penetration of x‐rays. It samples all emissions from the tissue, reconstructing the detectable light. The reconstruction then infers the site of the origin of the light where the radiation is absorbed and therefore which emits Cherenkov to the excited sensor molecule. This measurement therefore provides information on oxygen at that site (Pogue et al., 2018). This technique can provide excellent spatial resolution but more development of the technique is needed in order to take advantage of the benefits of spatial resolution. More generally, the benefits of optical methods come largely from their ability to tailor the imaging system to the problem. Currently, however, the logistics have not been solved for routine human use, nor have the probes been made in an FDA‐approved format for use in humans.

Photoacoustic tomography (PAT) is another optical technique that is becoming increasingly used to define perfusion and O2 saturation in preclinical cancer and investigational studies of breast tumors, with ongoing commercial development for broader clinical use in a number of ventures. The method relies on optical absorption of a pulsed laser source by chromophores in the tissue, including hemoglobin, to produce ultrasound waves which are detected at the surface. The major benefits of PAT in lesion imaging are high resolution for neovasculature imaging through ~1–2 cm of tissue, and the ability to image features of blood oxygen saturation with spectroscopic PAT. Quantitation of tissue oxygenation using PAT remains difficult because an indirect indicator of oxygenation is measured (i.e., blood oxygen saturation) and unknown tissue properties skew the light penetration in tissue, making accurate spectroscopic measurements challenging at nonsuperficial depths (Cox, Laufer, Beard, & Arridge, 2012).

4.1.4. NMR relaxation methods

Based on the principle that molecular O2 impacts the relaxation time of nuclei (Bennett et al., 1987; Swartz et al., 1985), several different approaches have been developed to try to use the power of NMR to measure O2 in tissues (Matsumoto et al., 2006). The measurement of O2 by NMR using isotopes with spin (O17 for NMR; Zhu & Chen, 2011) which is measured when the O2 is incorporated into water (and hence may better be considered as a measure of metabolism (Gallez, Neveu, Danhier, & Jordan, 2017; Neveu et al., 2015) and O15 for PET (Hattori et al., 2004) is possible, but these are extraordinarily expensive and not suitable for routine clinical use.

The most developed method has been the use of the relaxation time of fluorine nuclei in fluorinated hydrocarbons injected directly into tissues (Liu et al., 2011; Zhao, Jiang, & Mason, 2004). The measurements are based on the relaxation time of the F atoms in the emulsion, but the volume of the fluorine containing hydrocarbon is much larger than several capillary networks. Consequently, the data obtained are an average of a range of partial pressures. To date this approach has not advanced to clinical use.

There are a number of other NMR‐related approaches that have been suggested using the impact of O2 on the relaxation of protons (Colliez et al., 2014; O'Connor et al., 2009, 2016). Potentially these might provide spatially resolved data that could be quite useful. However, it is very unlikely that any could have the resolution to resolve the spatial heterogeneity of O2 in tissues. Thus, these measurements of O2 will be similar to the other techniques discussed, that is, their data will be based on assessing changes in “averaged” O2 levels.

4.2. Measures of O2 in the vascular system

Measures of O2 in the vascular system are based on the known relationship between the O2 saturation of hemoglobin (Hb) and the ambient pO2 as shown in the sigmoidal oxygen dissociation curve. However, the vascular system is, by its nature, not uniform with respect to its saturation. Arterial and venous systems have very different saturations, with the capillaries (which is where most O2 is delivered to the tissue) being in between these extremes. Therefore, when measurements such as pulse oximetry or NIRS report HbO2 saturation (Sakata, Grinberg, Grinberg, Springett, & Swartz, 2005), it is important to understand what part of the vascular system is being measured.

The problem with applying measurements of oxygen made in blood to measurements in tissues is that, while the amount of O2 in the vascular system is an important parameter impacting O2 levels in the perfused tissues, it is not possible to go directly from measuring O2 in blood to knowing the O2 in tissues. That is because O2 in the tissue is determined by many factors in addition to the potential supply of O2 from the red blood cells. Perfusion and diffusion must occur to get into the tissues. In some tissues, such as skeletal muscle and myocardium, the situation is even more complicated because of binding of oxygen by myoglobin. For example, some consumption of oxygen by cells will occur between the vascular system and the tissues of interest, and the number of cells and level of oxygen consumption by the cells can vary greatly. If tumors are present, the situation is further impacted by the chaotic nature of the neovasculature that arises in the tumors, with poorer perfusion and abnormal diffusion out of the vessels (Collins, Rudenski, Gibson, Howard, & O'Driscoll, 2015).

The other type of measurement of O2 in the vascular system is the measurement of blood gases (Davis, Walsh, Sittig, & Restrepo, 2013). These are usually done in larger vessels. These measurements have the same limitations as NIRS in regard to being able to provide information on the O2 levels in the extravascular tissue compartment.

Even though they are not measuring the actual increase of oxygen in tissues, measurements in the vascular system may be helpful in assessing response to techniques to increase O2 availability, because of ease of use and potential depth of sampling (Kim & Liu, 2008; Sunar et al., 2006).

While these tools are volume averaging over centimeters of tissue and the signal is dominated by areas of higher perfusion, the data on changes can provide clinically valuable information indicating that the oxygenation technique could be effective in raising levels of oxygen in the tissues of interest.

A related methodology, which is widely available, BOLD MRI (Thulborn, Waterton, Matthews, & Radda, 1982), is sometimes mistakenly thought to provide a direct measurement of O2 in the vascular system. But because it provides only one parameter, the amount of DeoxyHb, it cannot be used to assess HbO2 saturation or pO2 in the circulatory system. In principle, changes in the amount of the BOLD signal could be used to provide an indication of changing O2 levels. However, this type of use is limited by the fact that, if the blood volume within the sampled voxels changes, the amount of DeoxyHb will change even if the saturation remains the same and, therefore, the results may be confounded (Baudelet & Gallez, 2002). The potential time resolution is very fast.

4.3. Other indirect measures of tissue oxygen

There are a number of methods used clinically that attempt to provide indications of O2 levels in tissues, which are based on plausible but indirect relationships to the actual O2 levels. While these therefore intrinsically do not directly measure O2 in tissues, because of their widespread availability and, perhaps, some naivety among clinical users, they are sometimes considered to provide direct measurements of O2. This confusion has important implications for their usefulness in clinical applications because, while these techniques may provide valid and quantitative measures of parameters associated with their biological or chemical modes of interaction, their quantitative relationships to O2 levels may be poorly defined and potentially misinterpreted.

The use of molecules such as the nitroimidazoles and Cu‐ATSM that selectively localize in hypoxic tissues (O2 content <1%) has been widely employed, most often using PET labels to indicate their location (Busk et al., 2020; Chapman, Franko & Sharplin, 1981; Gutfilen, Souza, & Valentini, 2018; Kelada et al., 2017; Tran et al., 2012). The principle is that with critically low levels of O2 these can be reduced to reactive intermediates which, if not reoxidized by O2, can then bind to cellular components (Sealy, Swartz, & Olive, 1978). While these probes are widely used and often have been clinically useful, they clearly cannot provide a direct measure of the O2 content of the tissue. They can, nonetheless, provide a qualitative indication of regions with moderate to good perfusion that were hypoxic at the time that the tracer was delivered. When the nature of the data is understood, these techniques can be quite useful.

Another widely used PET clinical imaging technique is based on the observation that many tumors have a high rate of anaerobic and aerobic glycolysis and therefore a high uptake of glucose, which in turn can be followed by using the imaging agent 18F‐FDG (18F‐fluorodeoxyglucose; Lopci et al., 2014). The amount of uptake is based on a number of different factors including perfusion rate, extent of hypoxia, expression of the Warburg effect (i.e., aerobic glycolysis), number of cells, uptake of glucose analogs and rate of glycolysis (Vaupel & Multhoff, 2020; Vaupel et al., 2019). Clinical use of this technique is widespread and considered clinically useful for a number of contexts, especially in identifying regions where metabolically active tumor cells are located. Some clinicians even consider areas of high uptake as potentially indicating tumor hypoxia although the Warburg effect is mainly responsible for the high glucose uptake rates (Vaupel & Multhoff, 2020). A major complication is the high rate of false positives, due to many other causes of uptake of the agent (Britton & Robinson, 2016; Metser & Even‐Sapir, 2007). There can be very significant discrepancies between the pattern of localization of FDG and the histological evidence of hypoxia (Christian et al., 2009).

4.4. Endogenous hypoxia markers and other surrogates

Endogenous hypoxia markers (e.g., HIF‐1α, GLUT‐1, CA IX) are often used to judge the oxygenation status of malignant tumors. Responses to low oxygen levels in normal and cancer cells are mainly initiated by HIF‐1α, a key regulator for genes responsible for mammalian oxygen homeostasis. These responses (among others) include an increased erythropoiesis, angiogenesis, and glycolysis. The latter is mainly initiated by an enhanced cellular glucose uptake through GLUT‐1 transporters (Semenza, 1999, 2000). However, the expression of these markers is also driven by a series of other parameters as described in Section 3.2. Therefore, these proteins per se are not useful at all to judge the oxygenation/hypoxia status of benign and malignant tumors. The respective problems have been discussed in detail by Mayer, Höckel, and Vaupel (2008).

There is also a group of physiological measurements that are sometimes indirectly linked to O2. Measurements of blood flow, for example, MRI perfusion (Essig et al., 2013) and laser Doppler flow (Briers, 2001) are often used clinically to obtain a (surrogate) parameter that is potentially linked to the supply of O2. Because of the many factors that affect how much O2 is delivered and the impact of utilization on the amount of O2 is available, these techniques cannot by themselves provide reliable insights into the oxygenation status of the tissues. Measurements of metabolites that may be affected by O2 levels, for example, lactate and redox intermediates, are frequently used. However, their levels are the result of complex interactions that depend on many factors in addition to the amount of available O2, and therefore cannot reliably indicate O2 levels in tissues. Nonetheless, these physiological measurements, especially if repeated and related to appropriate other parameters, may in some instances provide useful clinical information.

5. DISCUSSION

5.1. Clinical value of indirect measurements of oxygen in tissues

It seems clear from both fundamental principles and the discussion in the previous sections that the use of indirect methods to directly determine the values for oxygen levels in tissues is not logical. This does not mean that such measurements intrinsically have no clinical value, but such uses do require careful consideration of a number of factors. At a minimum it requires a separate link, or calibration, of those indirect measurements, for example, lactate levels, to a method that measures O2 directly in tissues. There also needs to be an understanding of other types of links between the indirect and direct methods, so that there is adequate consideration of all factors that can affect the validity of that link, for example, many factors in addition to hypoxia can increase lactate levels in tissues.

In one of very few studies that actually attempts a head‐to‐head comparison of indirect methods of assessing hypoxia in the same tissue in humans, Nordsmark et al. (2007) compared 4 “hypoxia‐specific” indirect assays in 67 patients with head and neck cancer with a direct measure of O2 (using the Eppendorf electrode). They found that the indirect techniques differed in their relationship to the O2 measured by the electrode, and there were few correlations among the indirect assays. It seems quite possible that, even with the indirect techniques that seemed to correlate with the direct method (i.e., high plasma osteopontin and high HIF‐1α correlated with the Eppendorf method), the likelihood is that indirect methods would not always correlate well with each other because these parameters can be impacted by other factors as well. However, if they are to be used to predict O2 levels, it is important to identify those that strongly correlate with direct measures and/or to understand what other factors need to be measured in order to relate the information to O2 levels.

Of course, linking different candidate methods to a validated direct method, whether they are directly or indirectly assessing O2 in tissues, can also be useful to confirm which candidate measures would actually be poor or unreliable indicators of O2 in deep tissues, so that they should not be used for that purpose. Transcutaneous pO2 or surface pulse oximetry are two such examples. These techniques are relatively easy and noninvasive methods that can be repeated; they have been used to monitor arterial O2 near the surface or to identify proximal ischemia in patients with peripheral vascular disease (Abraham et al., 2003) or to monitor neonates in critical care units (Salyer, 2003). Despite the potential validity of these other uses, they are unlikely to be validated for O2 in deep tissues, because there is no plausible quantitative link between measurements of O2 made at the surface of the skin and deep tissue O2 levels.

There are some clinical trials that are using indirect methods to make clinical decisions, which may, under appropriate conditions, provide very useful clinical information even if they are not directly measuring O2 in tissues. An excellent example is a recent study using the PET reagent fluoromisonidazole (FMISO) labeled with fluorine‐18. FMISO was used as a surrogate for tumor O2 to determine whether FMISO data can be used as a guide to de‐escalate the radiation dose in patients being concurrently treated with chemotherapy for oropharyngeal papilloma virus related advanced tumors (Lee et al., 2016).

The ultimate criterion for clinical utility of indirect methods to measure tissue O2 will be the impact on outcomes. If there appears to be a benefit from such measurements based on outcomes, it will, of course be important to delineate the circumstances where this information is valid. Validity should include a recognition that the basis of the findings are correlations of measures of O2 with outcomes are not based on rigorous measurements of O2. This recognition is needed to prevent inappropriate extension to other uses.

5.2. Clinical value of direct measurements of oxygen in tissues

As we have shown above, whatever measuring method is employed, the volume that is sensed by the method will always be too large to be truly homogeneous because of the variations of O2 levels across small distance in tissues; (the variations are on a submillimeter scale!). In addition, the amount of O2 in the interrogated volumes may change very quickly, for example, in cycling hypoxia. Consequently, even direct measurements of O2 in tissues cannot accurately be reported as being a true single value. Instead, all current in vivo measurements purported to be measures of O2 levels in tissues are reflecting complex combinations of O2 levels, that is, are truly based on a mélange, that is, a mix of pO2 or [O2] values.

It is important to recognize that use of the term “absolute” in specification of pO2 can foster misinterpretations, and, in turn, can lead to inappropriate applications of these data to both clinical decision‐making and basic science theory. This is because, while the term “absolute” is correctly used to describe gas partial pressure measured in defined units above the pressure of an ideal vacuum, the term can be misinterpreted to connote measurements that are perfect, unbounded, definite, certain, etc. and these meanings, as we have shown, are inaccurate and misleading when applied to the in vivo circumstance. At a minimum, attention should be applied when using and interpreting the term “absolute” to describe O2 measurements, especially in the in vivo setting, and usage should be restricted to quantitative specification of vacuum as the zero of the defined scale, as opposed to a descriptor of data quality.

Although the inaccuracy and possible clinical misinterpretation of current measures of O2 levels in vivo has been argued before (Vaupel & Mayer, 2017a), the practice of providing single discrete values as definitive descriptors of oxygen levels, often specified as “absolute pO2” has persisted in the in vivo setting. The practice is abetted by being correct in some circumstances, that is, the techniques, especially when applied in restricted laboratory conditions, appear to provide valid measurements of pO2 or other rigorous parameters within specific volumes or limited time domains. But even then a valid measurement of an absolute pO2 in tissue does not assure that pO2 accurately reflects the pO2 in the tissue, for example, an EPR measurement of macroscopic sensor accurately provides the average value within the sensor but that is unlikely to reflect the heterogeneity of the tissue around the sensor. Another factor that encourages misinterpretation is the availability of robust data from model homogeneous systems, for example, cell cultures, that appear to indicate that clinical outcomes should be related to tissue O2 when applied to in vivo situations as well. More specifically, in studies conducted using homogeneous cell suspensions where the O2 levels can be rigorously controlled, the relationship between radiation sensitivity of cells and pO2 can be clearly demonstrated in vitro, but not necessarily demonstrable in vivo.

While we argue that simple measurements of oxygen levels cannot fully characterize the heterogeneity present in tissues and can easily be misleading, we do not argue that current measures of O2 levels and the data the techniques can collect are without potential value. On the contrary, if the limitations of measurements of O2 are taken into account in using this information clinically, these measurements can be immensely useful clinically. It is well established that various techniques can be used to provide clinically useful information, such as clinically significant changes in O2 in tissues as a result of disease progression and/or treatment, or to detect the presence of hypoxia. These assessments may be quantitative (with the noted caveats on interpretation of numerical values) or qualitative in nature, where, for example, binary characterizations may be provided (e.g., increasing vs. decreasing). Moreover, detecting changes in O2 in response to hyperoxygenation can be used, especially in the presence of severe hypoxia, to identify those patients who might benefit from receiving “hyperoxygenation” during treatment or otherwise modifying treatment doses. These assessments can then be exploited to enhance diagnosis and therapy, while keeping in mind the caveats involved in the interpretations of the values obtained from the measurements.

There are a number of significant implications of the thesis presented here for physiological researchers as well as for clinicians. Already noted is the potential danger of making too simplistic inferences based on studies conducted in cell cultures (Carreau, El Hafny‐Rahbi, Matejuk, Grillon, & Kieda, 2011; Keeley & Mann, 2019). These problems arise because the O2 level can be rigorously controlled in cell cultures (in the bulk medium where O2 levels may be at air pressure, but not in the unstirred layer at the cell surface), but they cannot be controlled when applied to tumors in vivo.

The implications for using measures of O2 to identify hypoxia in tumors to target areas to receive increased radiation doses (referred to as “dose painting”) are less clear, but these measures too should be based on understanding what is being painted. Currently, discussions of the potential advantages of increasing dose to more hypoxic regions of tumors have often focused on acquiring and applying definitive measurements of “absolute” pO2. As argued in this paper, this goal is not only unobtainable but also unnecessary. The really crucial goal is to find where there are likely to be more hypoxic cells in the tumor and accurately portray these regions. At least in a preclinical model (Epel et al., 2019), it has been shown that these areas can be estimated, and these estimates use techniques that are potentially feasible to apply to clinical settings. Techniques that can be used to make repeated measurements of changes in O2 during the course of therapy would likely be especially valuable to determine if the treatments were leading to different relative changes in O2 levels.

The data in Figure 2 (which are presented as uncalibrated O2 sensitive EPR line widths) illustrate the potential clinical usefulness of using relative measurements of O2, that are not rooted in being “absolute” pO2 values. Recall that the data illustrate both the ability to gather repeated O2 measurements over a short time (minutes) and a long period (weeks or months). For clinical utility, having data from the short period (30 min in this case) could be used to determine whether a given patient's tumor is responsive to hyperoxic gas mixtures administered during preparation for and delivery of a typical fraction of radiation. This knowledge could help clinicians to determine when patients can benefit from strategies to enhance the effectiveness of radiation by using hyperoxygenation during treatment. The longer period of repetition (6 weeks in this case) could be used to monitor continued responsiveness of the tumor to hyperoxygenation during treatment and could monitor whether any changes occurred in the baseline measurements across a usual several‐week course of radiation.

As another example, there are considerable data from studies carried out 15–25 years ago using the Eppendorf histography, that is, using a polarographic system to make pretreatment assessments of the hypoxic fraction in patients and then, without changing therapy, looking at the relationships between pretreatment O2 data and outcomes (Höckel et al., 1993, 1996; Nordsmark et al., 2005).These findings, in brief, suggested a very strong prognostic relationship between identifying severely hypoxic tumors and having poorer outcomes following treatment.

These data were certainly “averaged” values of O2, in view of the intrinsic variability of such measurements (as illustrated by the multiple data acquisitions along several tracks in the Höckel/Vaupel laboratory), the variations among laboratories (Nordsmark et al., 2005), and the intrinsic nature of the data where each point inevitably includes data from a volume that is very likely to have heterogenous oxygen levels. In spite of these limitations and the fact that the measurements could not be repeated, it still could have been possible to apply their findings to change treatments based on their pretreatment measures. For example, patients with indications of high hypoxic fractions (i.e., Eppendorf measures suggested their tumor was very hypoxic) could have been prescribed treatments (assuming options were available) that were not as affected by the presence of large numbers of hypoxic cells (like avoiding radiation and instead using chemotherapy or immunotherapy). Alternatively, the patients could be targeted to utilize treatments designed to decrease the hypoxic fractions prior to or during treatment.

Although the Eppendorf histography system is no longer used in the clinic, its use resulted in very excellent insights into the importance of tumor hypoxia on the response to therapy. Especially if comparative measurements could be made repeatedly over time to follow treatment and attempts to modify local tissue oxygen that information could be used to personalize treatments, for example to deliver therapy under more favorable conditions and/or determine the effectiveness of interventions aimed at decreasing local hypoxia. In summary, a key implication, especially illustrated for cancer, is that the most useful clinical value of measurements of direct, or even indirect, measurements of O2 in tissue, is to follow temporal changes that occur by: (1) treatment‐enhancing interventions (especially hyperoxic interventions to increase O2 in the hypoxic regions of the tumor), (2) consequences of therapy (especially the impact from radiation but also immunotherapy, chemotherapy, hormone therapy, and surgery), and (3) disease progression. Of course, establishing the clinical value of these measurements of O2 will ultimately require appropriate studies of the outcomes of therapy using the O2 measurements to guide choices.

There are similar implications for the use of measurements of O2 in some other diseases. The most important other clinical application is likely to be for peripheral vascular disease (PVD). Relative measurements of O2 may help to identify and follow changes in levels of relatively low oxygenation (for arterial disease) or the location of tissues at risk for diabetic PVD (Editors, 2012). The clinically most import information may be to determine if there is a demonstrable impact on tissue O2 from interventions (drugs or surgical) and to follow the course of the disease.

For such applications the key information will be changes, not absolute values. So, the challenge is to have an ability to measure repeatedly at the same site with a parameter that reflects the oxygenation in the tissue. Such measurements have the potential to very significantly improve clinical outcomes, but, as noted for their use in cancer, the ultimate proof of their value needs to come from appropriate studies of outcomes.

Other types of clinical applications where changes rather than attempts to measure absolute values will be clinically valuable include: monitoring the status of healing wounds (including the status of tissue flaps, especially to determine the need for autologous skin transplants), and monitoring and avoiding untoward side effects of treatment (e.g., debilitating fibrosis caused by radiation or excessive chemotherapy‐induced peripheral nerve pain).

6. CONCLUSIONS

The bottom line is that clinical measurements of O2 in tissues will inevitably provide results that are, at best, based on data that do not fully reflect the inherent heterogeneity of O2 in tissues over space and time. Additionally, the nature of all existing techniques to measure O2 results in complex sampling of the volume that is sensed by the technique. By recognizing these potential limitations of the measures, one can focus on the very important and useful information that can be obtained from these techniques, especially data about factors that can change levels of O2, and then exploit these changes diagnostically and therapeutically. Many examples already exist where measurements of oxygen in tissues have had significant clinical utility, even though in retrospect they really did not provide unambiguous information on absolute values of oxygen in the tissues. The clinical utility of such data ultimately needs to be verified by careful studies of outcomes related to the measured changes in levels of O2. For both basic physiological and clinical purposes, it is likely that the most useful information is likely to be obtained by employing multiple types of measurements that can thereby overcome the inevitable limitations of a single type of measurement.

CONFLICTS OF INTEREST

HMS and ABF are owners of Clin‐EPR, LLC, which manufactures and sells clinical EPR instruments for investigational use only. HJH is a member of O2M Technologies which manufactures preclinical pO2 imagers and has pertinent patents.

AUTHOR CONTRIBUTIONS

Drs. Swartz, Flood, and Vaupel are the lead authors. All authors have either contributed to the conception and design of this paper or to the interpretation of data and analyses as well as drafting or revising it critically for intellectual content. All have approved the final content of this work, agree to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved, and represent all who qualify for authorship. We gratefully acknowledge all other scientists, clinicians, engineers, and coordinators on the PPG.

Swartz HM, Flood AB, Schaner PE, et al. How best to interpret measures of levels of oxygen in tissues to make them effective clinical tools for care of patients with cancer and other oxygen-dependent pathologies. Physiol Rep. 2020;8:e14541 10.14814/phy2.14541

Funding information

Major funding for this work was from the National Institutes of Health, National Cancer Institute, PPG Grant P01CA190193, R01 CA 098575, P30 CA023108, and National Institute of Biomedical Imaging and Bioengineering P41 002034.

REFERENCES

  1. Abraham, P. , Picquet, J. , Vielle, B. , Sigaudo‐Roussel, D. , Paisant‐Thouveny, F. , Enon, B. , & Saumet, J.‐L. (2003). Transcutaneous oxygen pressure measurements on the buttocks during exercise to detect proximal arterial ischemia: Comparison with arteriography. Circulation, 107, 1896–1900. 10.1161/01.CIR.0000060500.60646.E0 [DOI] [PubMed] [Google Scholar]
  2. Baudelet, C. , Ansiaux, R. , Jordan, B. F. , Havaux, X. , Macq, B. , & Gallez, B. (2004). Physiological noise in murine solid tumours using T2*‐weighted gradient‐echo imaging: A marker of tumour acute hypoxia? Physics in Medicine & Biology, 49(15), 3389–3411. 10.1088/0031-9155/49/15/006 [DOI] [PubMed] [Google Scholar]
  3. Baudelet, C. , & Gallez, B. (2002). How does blood oxygen level‐dependent (BOLD) contrast correlate with oxygen partial pressure (pO2) inside tumors? Magnetic Resonance in Medicine, 48(6), 980–986. [DOI] [PubMed] [Google Scholar]
  4. Bennett, H. F. , Swartz, H. M. , Brown, R. D. III , & Koenig, S. H. (1987). Modification of relaxation of lipid protons by molecular oxygen and nitroxides. Investigative Radiology, 22, 502–507. 10.1097/00004424-198706000-00011 [DOI] [PubMed] [Google Scholar]
  5. Braun, R. D. , Lanzen, J. L. , & Dewhirst, M. W. (1999). Fourier analysis of fluctuations of oxygen tension and blood flow in R3230Ac tumors and muscle in rats. American Journal of Physiology, 277(2 Pt 2), H551–568. [DOI] [PubMed] [Google Scholar]
  6. Briers, D. J. (2001). Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging. Physiological Measurement, 22(4), R35–66. 10.1088/0967-3334/22/4/201 [DOI] [PubMed] [Google Scholar]
  7. Britton, T. , & Robinson, N. (2016). Pitfalls and pearls of wisdom in 18F‐FDG pet imaging of tumors. Journal of Nuclear Medicine Technology, 44, 59–64. 10.2967/jnmt.115.170803 [DOI] [PubMed] [Google Scholar]
  8. Busk, M. , Overgaard, J. , & Horsman, M. R. (2020). Imaging of tumor hypoxia for radiotherapy: Current status and future directions. Seminars in Nuclear Medicine (in press). 10.1053/j.semnuclmed.2020.05.003 [DOI] [PubMed] [Google Scholar]
  9. Carreau, A. , El Hafny‐Rahbi, B. , Matejuk, A. , Grillon, C. , & Kieda, C. (2011). Why is the partial oxygen pressure of human tissues a crucial parameter? Small molecules and hypoxia. Journal of Cellular and Molecular Medicine, 15(6), 1239–1253. [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. Chapman, J. D. , Franko, A. J. , & Sharplin, J. (1981). A marker for hypoxic cells in tumors with potential clinical applicability. British Journal of Cancer, 43, 546–550. [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Christian, N. , Lee, J. A. , Bol, A. , De Bast, M. , Jordan, B. , & Grégoire, V. (2009). The limitation of PET imaging for biological adaptive‐IMRT assessed in animal models. Radiotherapy and Oncology, 91(1), 101–106. 10.1016/j.radonc.2008.11.014 [DOI] [PubMed] [Google Scholar]
  12. Clyne, C. A. , Ramsden, W. H. , Chant, A. D. , & Webster, J. H. (1985). Oxygen tension on the skin of the gaiter area of limbs with venous disease. British Journal of Surgery, 72(8), 644–647. 10.1002/bjs.1800720820 [DOI] [PubMed] [Google Scholar]
  13. Colliez, F. , Neveu, M. A. , Magat, J. , Cao Pham, T. T. , Gallez, B. , & Jordan, B. F. (2014). Qualification of a noninvasive magnetic resonance imaging biomarker to assess tumor oxygenation. Clinical Cancer Research, 20(21), 5403–5411. 10.1158/1078-0432.CCR-13-3434 [DOI] [PubMed] [Google Scholar]
  14. Collins, J.‐A. , Rudenski, A. , Gibson, J. , Howard, L. , & O'Driscoll, R. (2015). Relating oxygen partial pressure, saturation and content: The haemoglobin–oxygen dissociation curve. Breathe (Sheff), 11(3), 194–201. 10.1183/20734735.001415 [DOI] [PMC free article] [PubMed] [Google Scholar]
  15. Cox, B. T. , Laufer, J. G. , Beard, P. C. , & Arridge, S. R. (2012). Quantitative spectroscopic photoacoustic imaging: A review. Journal of Biomedical Optics, 17(6), 061202 10.1117/1.JBO.17.6.061202 [DOI] [PubMed] [Google Scholar]
  16. Davis, M. D. , Walsh, B. K. , Sittig, S. E. , & Restrepo, R. D. (2013). AARC Clinical Practice Guideline: Blood gas analysis and hemoximetry: 2013. Respir Care, 58(10), 1694–1703. 10.4187/respcare.02786 [DOI] [PubMed] [Google Scholar]
  17. Editors . (2012). Peripheral vascular disease in Circulation and the Circulation Subspecialty Journals. Circulation 125, 600–661. [Google Scholar]
  18. Egeland, T. A. , Gaustad, J. V. , Vestvik, I. K. , Benjaminsen, I. C. , Mathiesen, B. , & Rofstad, E. K. (2006). Assessment of fraction of radiobiologically hypoxic cells in human melanoma xenografts by dynamic contrast‐enhanced MRI. Magnetic Resonance in Medicine, 55(4), 874–882. 10.1002/mrm.20852 [DOI] [PubMed] [Google Scholar]
  19. Epel, B. , Bowman, M. K. , Mailer, C. , & Halpern, H. J. (2014). Absolute oxygen R1e imaging in vivo with pulse electron paramagnetic resonance. Magnetic Resonance in Medicine, 72(2), 362–368. [DOI] [PMC free article] [PubMed] [Google Scholar]
  20. Epel, B. , Maggio, M. C. , Barth, E. D. , Miller, R. C. , Pelizzari, C. A. , Krzykawska‐Serda, M. , … Halpern, H. J. (2019). Oxygen‐guided radiation therapy. International Journal of Radiation Oncology Biology Physics, 103(4), 977–984. 10.1016/j.ijrobp.2018.10.041 [DOI] [PMC free article] [PubMed] [Google Scholar]
  21. Erickson, K. , Braun, R. D. , Yu, D. , Lanzen, J. , Wilson, D. , Brizel, D. M. , … Dewhirst, M. W. (2003). Effect of longitudinal oxygen gradients on effectiveness of manipulation of tumor oxygenation. Cancer Research, 63(15), 4705–4712. [PubMed] [Google Scholar]
  22. Esipova, T. V. , Barrett, M. J. P. , Erlebach, E. , Masunov, A. E. , Weber, B. , & Vinogradov, S. A. (2019). Oxyphor 2P: A high‐performance probe for deep‐tissue longitudinal oxygen imaging. Cell Metabolism, 29(3), 736–744. 10.1016/j.cmet.2018.12.022 [DOI] [PMC free article] [PubMed] [Google Scholar]
  23. Esipova, T. V. , Karagodov, A. , Miller, J. , Wilson, D. F. , Busch, T. M. , & Vinogradov, S. A. (2011). Two new “protected” oxyphors for biological oximetry: Properties and application in tumor imaging. Analytical Chemistry, 83(22), 8756–8765. 10.1021/ac2022234 [DOI] [PMC free article] [PubMed] [Google Scholar]
  24. Essig, M. , Shiroishi, M. S. , Nguyen, T. B. , Saake, M. , Provenzale, J. M. , Enterline, D. , … Law, M. (2013). Perfusion MRI: The five most frequently asked technical questions. American Journal of Roentgenology, 200, 24–34. 10.2214/AJR.12.9543 [DOI] [PMC free article] [PubMed] [Google Scholar]
  25. Falk, S. J. , Ward, R. , & Bleehen, N. M. (1992). The influence of carbogen breathing on tumour tissue oxygenation in man evaluated by computerised pO2 histography. British Journal of Cancer, 66, 919–924. [DOI] [PMC free article] [PubMed] [Google Scholar]
  26. Flood, A. B. , Schaner, P. E. , Vaupel, P. , Williams, B. B. , Gallez, B. , Chen, E. Y. , … Swartz, H. M. (2020). Clinical and statistical considerations when assessing oxygen levels in tumors: Illustrative results from clinical EPR oximetry studies. Advances in Experimental Medicine and Biology, 1232, 155–168. [DOI] [PubMed] [Google Scholar]
  27. Fukumura, D. , Duda, D. G. , Munn, L. L. , & Jain, R. K. (2010). Tumor microvasculature and microenvironment: Novel insights through intravital imaging in pre‐clinical models. Microcirculation, 17(3), 206–225. 10.1111/j.1549-8719.2010.00029.x [DOI] [PMC free article] [PubMed] [Google Scholar]
  28. Gallez, B. , Neveu, M. A. , Danhier, P. , & Jordan, B. F. (2017). Manipulation of tumor oxygenation and radiosensitivity through modification of cell respiration: A critical review of approaches and imaging biomarkers for therapeutic guidance. Biochimica Et Biophysica Acta (BBA) – Bioenergetics, 1858(8), 700–711. 10.1016/j.bbabio.2017.01.002 [DOI] [PubMed] [Google Scholar]
  29. Graffman, S. , Bjork, P. , Ederoth, P. , & Ihse, I. (2001). Polarographic pO2 measurements of intra‐abdominal adenocarcinoma in connection with intraoperative radiotherapy before and after change of oxygen concentration of anaesthetic gases. Acta Oncologica, 40(1), 105–107. [DOI] [PubMed] [Google Scholar]
  30. Griffith, T. M. (1996). Temporal chaos in the microcirculation. Cardiovascular Research, 3, 342–358. 10.1016/S0008-6363(95)00147-6 [DOI] [PubMed] [Google Scholar]
  31. Günther, H. , Aumüller, G. , Kunke, S. , Vaupel, P. , & Thews, G. (1974). Verteilung der O2‐Drucke in der Rattenniere unter Normbedingungen (Distribution of the O2 pressures in the rat kidney under standard conditions). Research in Experimental Medicine, 163, 251–264. [DOI] [PubMed] [Google Scholar]
  32. Gutfilen, B. , Souza, S. A. L. , & Valentini, G. (2018). Copper‐64: A real theranostic agent. Drug Design, Develop Therapy, 12, 3235–3245. [DOI] [PMC free article] [PubMed] [Google Scholar]
  33. Harrison, D. , & Vaupel, P. (2014). Heterogeneity in tissue oxygenation: From physiological variability in normal tissues to pathophysiological chaos in malignant tumors. Advances in Experimental Medicine and Biology, 812, 25–31. [DOI] [PubMed] [Google Scholar]
  34. Hattori, N. , Bergsneider, M. , Wu, H. M. , Glenn, T. C. , Vespa, P. M. , Hovda, D. A. , … Huang, S. C. (2004). Accuracy of a method using short inhalation of 15O–O2 for measuring cerebral oxygen extraction fraction with PET in healthy humans. Journal of Nuclear Medicine, 45, 765–770. [PubMed] [Google Scholar]
  35. Höckel, M. , Knoop, C. , Schlenger, K. , Vorndran, B. , Baussmann, E. , Mitze, M. , … Vaupel, P. (1993). Intratumoral pO2 predicts survival in advanced cancer of the uterine cervix. Radiotherapy and Oncology, 26, 45–50. 10.1016/0167-8140(93)90025-4 [DOI] [PubMed] [Google Scholar]
  36. Höckel, M. , Schlenger, K. , Aral, B. , Mitze, M. , Schaffer, U. , & Vaupel, P. (1996). Association between tumor hypoxia and malignant progression in advanced cancer of the uterine cervix. Cancer Research, 56, 4509–4515. [PubMed] [Google Scholar]
  37. Höckel, M. , Schlenger, K. , Knoop, C. , & Vaupel, P. (1991). Oxygenation of carcinomas of the uterine cervix: Evaluation by computerized O2 tension measurements. Cancer Research, 51(22), 6098–6102. [PubMed] [Google Scholar]
  38. Hodson, L. (2014). Adipose tissue oxygenation: Effects on metabolic function. Adipocyte, 3(1), 75–80. 10.4161/adip.27114 [DOI] [PMC free article] [PubMed] [Google Scholar]
  39. Hogeboom van Buggenum, I. M. , van der Heijde, G. L. , Tangelder, G. J. , & Reichert‐Thoen, J. W. M. (1996). Occular oxygen measurement. British Journal of Ophthalmology, 80, 567–575. [DOI] [PMC free article] [PubMed] [Google Scholar]
  40. Hou, H. , Khan, N. , Gohain, S. , Kuppusamy, M. L. , & Kuppusamy, P. (2018). Pre‐clinical evaluation of OxyChip for long‐term EPR oximetry. Biomedical Microdevices, 20(2), 29 10.1007/s10544-018-0272-x [DOI] [PubMed] [Google Scholar]
  41. Hou, H. , Khan, N. , Nagane, M. , Gohain, S. , Chen, E. Y. , Jarvis, L. A. , … Kuppusamy, P. (2016). Skeletal muscle oxygenation measured by EPR oximetry using a highly sensitive polymer‐encapsulated paramagnetic sensor. Advances in Experimental Medicine and Biology, 923, 351–357. [DOI] [PMC free article] [PubMed] [Google Scholar]
  42. Jain, R. K. (2005). Normalization of tumor vasculature: An emerging concept in antiangiogenic therapy. Science, 307(5706), 58–62. 10.1126/science.1104819 [DOI] [PubMed] [Google Scholar]
  43. Jarvis, L. A. , Williams, B. B. , Schaner, P. E. , Chen, E. Y. , Angeles, C. V. , Hou, H. , … Kuppusamy, P. (2016). Phase 1 clinical trial of OxyChip, an implantable absolute pO2 sensor for tumor oximetry. International Journal of Radiation Oncology*biology*physics, 96(2), S109–S110. 10.1016/j.ijrobp.2016.06.268 [DOI] [Google Scholar]
  44. Jeong, J. J. , Liu, T. , Yang, X. , Torres, M. , Lin, J. , Schreiber, W. , … Ali, A. (2019). Clinical measurements of oxygen via electron paramagnetic resonance (EPR) during and after breast radiation therapy: Preliminary results of baseline evaluations and response to hyperoxygenation. Journal of Radiology and Radiation Therapy, 7(1), 1082. [Google Scholar]
  45. Jordan, B. F. , Magat, J. , Colliez, F. , Ozel, E. , Fruytier, A. C. , Marchand, V. , … Gallez, B. (2013). Mapping of oxygen by imaging lipids relaxation enhancement: A potential sensitive endogenous MRI contrast to map variations in tissue oxygenation. Magnetic Resonance in Medicine, 70(3), 732–744. 10.1002/mrm.24511 [DOI] [PubMed] [Google Scholar]
  46. Jung, F. , Kessler, H. , Pindur, G. , Sternitzky, R. , & Franke, R. P. (1999). Intramuscular oxygen partial pressure in the healthy during exercise. Clinical Hemorheology and Microcirculation, 21(1), 25–33. [PubMed] [Google Scholar]
  47. Kallinowski, F. , & Buhr, H. J. (1995a). Tissue oxygenation of primary, metastatic and xenografted rectal cancers In Vaupel P., Kelleher D. K., & Günderoth M. (Eds.), Tumor oxygenation (pp. 205–209). Stuttgart, Jena, New York: Fischer. [Google Scholar]
  48. Kallinowski, F. , & Buhr, H. J. (1995b). Can the oxygenation status of rectal carcinomas be improved by hypoxia? In Vaupel P., Kelleher D. K. & Günderoth M. (Eds.), Tumor oxygenation (pp. 291–296). Stuttgart, Jena, New York: Fischer. [Google Scholar]
  49. Keeley, T. P. , & Mann, G. E. (2019). Defining physiological normoxia for improved translation of cell physiology to animal models and humans. Physiological Reviews, 99, 161–234. 10.1152/physrev.00041.2017 [DOI] [PubMed] [Google Scholar]
  50. Kelada, O. J. , Rockwell, S. , Zheng, M. Q. , Huang, Y. , Liu, Y. , Booth, C. J. , … Carlson, D. J. 2017. Quantification of tumor hypoxic fractions using positron emission tomography with [18 F] fluoromisonidazole ([18 F] FMISO) kinetic analysis and invasive oxygen measurements. Molecular imaging and biology, 19(6), 893–902. [DOI] [PMC free article] [PubMed] [Google Scholar]
  51. Khan, N. , Shen, J. , Chang, T. Y. , Chang, C. C. , Fung, P. C. , Grinberg, O. , … Swartz, H. M. (2003). Plasma membrane cholesterol: A possible barrier to intracellular oxygen in normal and mutant CHO cells defective in cholesterol metabolism. Biochem, 42, 23–29. [DOI] [PubMed] [Google Scholar]
  52. Kim, J. G. , & Liu, H. (2008). Investigation of biphasic tumor oxygen dynamics induced by hyperoxic gas intervention: The dynamic phantom approach. Applied Optics, 47(2), 242–252. 10.1364/AO.47.000242 [DOI] [PubMed] [Google Scholar]
  53. Kimura, H. , Braun, R. D. , Ong, E. T. , Hsu, R. , Secomb, T. W. , Papahadjopoulos, D. , … Dewhirst, M. W. (1996). Fluctuations in red cell flux in tumor microvessels can lead to transient hypoxia and reoxygenation in tumor parenchyma. Cancer Research, 56, 5522–5528. [PubMed] [Google Scholar]
  54. Koch, C. J. (2002). Measurement of absolute oxygen levels in cells and tissues using oxygen sensors and 2‐nitroimidazole EF5. Methods in Enzymology, 352, 3–31. [DOI] [PubMed] [Google Scholar]
  55. Konerding, M. A. , Fait, E. , & Gaumann, A. (2001). 3D microvascular architecture of pre‐cancerous lesions and invasive carcinomas of the colon. British Journal of Cancer, 84, 1354–1362. [DOI] [PMC free article] [PubMed] [Google Scholar]
  56. Koong, A. C. , Mehta, V. K. , Le, Q. T. , Fisher, G. A. , Terris, D. J. , Brown, J. M. , … Vierra, M. (2000). Pancreatic tumors show high levels of hypoxia. International Journal of Radiation Oncology, Biology, Physics, 48(4):919–922. [DOI] [PubMed] [Google Scholar]
  57. Kurokawa, H. , Ito, H. , Inoue, M. , Tabata, K. , Sato, Y. , Yamagata, K. , … Kamachi, T. (2015). High resolution imaging of intracellular oxygen concentration by phosphorescence lifetime. Scientific Reports, 5, 10657 10.1038/srep10657 [DOI] [PMC free article] [PubMed] [Google Scholar]
  58. Lan, M. , Beghein, N. , Charlier, N. , & Gallez, B. (2004). Carbon blacks as EPR sensors for localized measurements of tissue oxygenation. Magnetic Resonance in Medicine, 51(6), 1272–1278. 10.1002/mrm.20077 [DOI] [PubMed] [Google Scholar]
  59. Landgraf, H. , & Ehrly, A. M. (1980). Oxygen tension in the arterial blood and in muscle tissue in healthy persons of different age (author's transl). Akt Gerontol, 10(11), 511–514. [PubMed] [Google Scholar]
  60. Landgraf, H. , Schulte‐Huermann, D. , Vallbracht, C. , & Ehrly, A. M. (1994). Muscle tissue PO2 during moderate altitude exposure in patients with peripheral arterial occlusive disease. La Presse Médicale, 23(4), 164–168. [PubMed] [Google Scholar]
  61. Lartigau, E. , Randrianarivelo, H. , Avril, M. F. , Margulis, A. , Spatz, A. , Eschwege, F. , & Guichard, M. (1997). Intratumoral oxygen tension in metastatic melanoma. Melanoma Research, 7, 400–406. [DOI] [PubMed] [Google Scholar]
  62. Lawrentschuk, N. , Poon, A. M. , Foo, S. S. , Putra, L. G. , Murone, C. , Davis, I. D. , … Scott, A. M. (2005). Assessing regional hypoxia in human renal tumours using 18F‐fluoromisonidazole positron emission tomography. BJU International, 96(4), 540–546. 10.1111/j.1464-410X.2005.05681.x [DOI] [PubMed] [Google Scholar]
  63. Le, Q. T. , Chen, F. , Salim, A. , Cao, H. , Kong, C. S. , Whyte, R. , … Giaccia, A. J. (2006). An evaluation of tumor oxygenation and gene expression in patients with early stage non‐small cell lung cancers. Clinical Cancer Research, 12, 1507–1514. [DOI] [PubMed] [Google Scholar]
  64. Lee, N. , Schoder, H. , Beattie, B. , Lanning, R. , Riaz, N. , McBride, S. , … Humm, J. (2016). Strategy of using intratreatment hypoxia imaging to selectively and safely guide radiation dose de‐escalation concurrent with chemotherapy for locoregionally advanced human papillomavirus‐related oropharyngeal carcinoma. International Journal of Radiation Oncology Biology Physics, 96(1), 9–17. 10.1016/j.ijrobp.2016.04.027 [DOI] [PMC free article] [PubMed] [Google Scholar]
  65. Lempesis, I. G. , van Meijel, R. L. J. , Manolopoulos, K. N. , & Goossens, G. H. (2020). Oxygenation of adipose tissue: A human perspective. Acta Physiol (Oxford), 228(1), e13298 10.1111/apha.13298 [DOI] [PMC free article] [PubMed] [Google Scholar]
  66. Linsenmeier, R. A. , & Zhang, H. F. (2017). Retinal oxygen: From animals to humans. Progress in Retinal and Eye Research, 58, 115–151. [DOI] [PMC free article] [PubMed] [Google Scholar]
  67. Liu, S. , Shah, S. J. , Wilmes, L. J. , Feiner, J. , Kodibagkar, V. D. , Wendland, M. F. , … Rollins, M. D. (2011). Quantitative tissue oxygen measurement in multiple organs using 19F MRI in a rat model. Magnetic Resonance in Medicine, 66, 1722–1730. [DOI] [PMC free article] [PubMed] [Google Scholar]
  68. Lopci, E. , Grassi, I. , Chiti, A. , Nanni, C. , Cicoria, G. , Toschi, L. , … Fanti, S. (2014). PET radiopharmaceuticals for imaging of tumor hypoxia: A review of the evidence. American Journal of Nuclear Medicine and Molecular Imaging, 4(4), 365–384. [PMC free article] [PubMed] [Google Scholar]
  69. Macnab, A. J. , Gagnon, R. , Gagnon, F. , Minchinton, A. I. , & Fry, K. H. (2003). Simultaneous pO2 and HbO2 measurement to determine absolute HbO2 concentration for in vivo near infrared spectroscopy. Spectroscopy, 17, 289–295. [Google Scholar]
  70. Matsumoto, K. , Bernardo, M. , Subramanian, S. , Choyke, P. , Mitchell, J. B. , Krishna, M. C. , & Lizak, M. J. (2006). MR assessment of changes of tumor in response to hyperbaric oxygen treatment. Magnetic Resonance in Medicine, 56, 240–246. 10.1002/mrm.20961 [DOI] [PubMed] [Google Scholar]
  71. Mattern, J. , Kallinowski, F. , Herfarth, C. , & Volm, M. (1996). Association of resistance‐related protein expression with poor vascularization and low levels of oxygen in human rectal cancer. International Journal of Cancer, 67(1), 20–23. [DOI] [PubMed] [Google Scholar]
  72. Mayer, A. , Höckel, M. , & Vaupel, P. (2008). Endogenous hypoxia markers: Case not proven! Advances in Experimental Medicine and Biology, 614, 127–136. [DOI] [PubMed] [Google Scholar]
  73. Metser, U. , & Even‐Sapir, E. (2007). Increased 18F‐Fluorodeoxyglucose uptake in benign, nonphysiologic lesions found on whole‐body positron emission tomography/computed tomography (PET/CT): Accumulated data from four years of experience with PET/CT. Seminars in Nuclear Medicine, 37, 206–222. 10.1053/j.semnuclmed.2007.01.001 [DOI] [PubMed] [Google Scholar]
  74. Mik, E. G. (2013). Special article: Measuring mitochondrial oxygen tension: From basic principles to application in humans. Anesthesia and Analgesia, 117(4), 834–846. [DOI] [PubMed] [Google Scholar]
  75. Mik, E. G. , Stap, J. , Sinaasappel, M. , Beek, J. F. , Aten, J. A. , van Leeuwen, T. G. , & Ince, C. (2006). Mitochondrial pO2 measured by delayed fluorescence of endogenous protoporphyrin IX. Nature Methods, 11, 939–945. 10.1038/nmeth940 [DOI] [PubMed] [Google Scholar]
  76. Möller, M. M. , Li, Q. , Chinnaraj, M. , Cheung, H. C. , Lancaster, J. R. Jr , & Denicola, A. (2016). Solubility and diffusion of oxygen in phospholipid membranes. Biochimica Et Biophysica Acta (BBA) ‐ Biomembranes, 1858(11), 2923–2930. 10.1016/j.bbamem.2016.09.003 [DOI] [PubMed] [Google Scholar]
  77. Moss, A. J. (1968). Intramyocardial oxygen tension. Cardiovascular Research, 2(3), 314–318. 10.1093/cvr/2.3.314 [DOI] [PubMed] [Google Scholar]
  78. Neveu, M. A. , Bol, V. , Bol, A. , Bouzin, C. , Grégoire, V. , Feron, O. , … Gallez, B. (2015). The increase in tumor oxygenation under carbogen breathing induces a decrease in the uptake of [(18)F]‐fluoro‐deoxy‐glucose. Radiotherapy and Oncology, 116(3), 400–403. 10.1016/j.radonc.2015.04.023 [DOI] [PubMed] [Google Scholar]
  79. Nordsmark, M. , Bentzen, S. M. , Rudat, V. , Brizel, D. , Lartigau, E. , Stadler, P. , … Overgaard, J. (2005). Prognostic value of tumor oxygenation in 397 head and neck tumors after primary radiation therapy. An international multi‐center study. Radiotherapy and Oncology, 77(1), 18–24. [DOI] [PubMed] [Google Scholar]
  80. Nordsmark, M. , Eriksen, J. G. , Gebski, V. , Alsner, J. , Horsman, M. R. , & Overgaard, J. (2007). Differential risk assessments from five hypoxia specific assays: The basis for biologically adapted individualized radiotherapy in advanced head and neck cancer patients. Radiotherapy and Oncology, 83, 389–397. 10.1016/j.radonc.2007.04.021 [DOI] [PubMed] [Google Scholar]
  81. O'Connor, J. P. , Boult, J. K. , Jamin, Y. , Babur, M. , Finegan, K. G. , Williams, K. J. , … Robinson, S. P. (2016). Oxygen‐enhanced MRI accurately identifies, quantifies, and maps tumor hypoxia in preclinical cancer models. Cancer Research, 76(4), 787–795. 10.1158/0008-5472.CAN-15-2062 [DOI] [PMC free article] [PubMed] [Google Scholar]
  82. O'Connor, J. P. , Naish, J. H. , Jackson, A. , Waterton, J. C. , Watson, Y. , Cheung, S. , … Parker, G. J. (2009). Comparison of normal tissue R‐1 and R‐2* modulation by oxygen and carbogen. Magnetic Resonance in Medicine, 61, 75–83. [DOI] [PubMed] [Google Scholar]
  83. Ortez‐Prado, E. , Dunn, J. F. , Vasconez, J. , Castillo, D. , & Visco, G. (2019). Partial pressure of oxygen in the human body: A general review. American Journal of Blood Research, 9(1), 1–14. [PMC free article] [PubMed] [Google Scholar]
  84. Pasarica, M. , Sereda, O. R. , Redman, L. M. , Albarado, D. C. , Hymel, D. T. , Roan, L. E. , … Smith, S. R. (2009). Reduced adipose tissue oxygenation in human obesity: Evidence for rarefaction, macrophage chemotaxis, and inflammation without an angiogenic response. Diabetes, 58(3), 718–725. [DOI] [PMC free article] [PubMed] [Google Scholar]
  85. Pias, S. C. (2020). Pathways of oxygen diffusion in cells and tissues: Hydrophobic channeling via networked lipids. Advances in Experimental Medicine and Biology, 1232, 183–190. [DOI] [PMC free article] [PubMed] [Google Scholar]
  86. Pogue, B. W. , Feng, J. , LaRochelle, E. P. , Bruža, P. , Lin, H. , Zhang, R. , … Jarvis, L. A. (2018). Maps of in vivo oxygen pressure with submillimetre resolution and nanomolar sensitivity enabled by Cherenkov‐excited luminescence scanned imaging. Nature Biomedical Engineering, 2(4), 254–264. 10.1038/s41551-018-0220-3 [DOI] [PMC free article] [PubMed] [Google Scholar]
  87. Powell, M. E. B. , Collingridge, D. R. , Saunders, M. I. , Hoskin, P. J. , Hill, S. A. , & Chaplin, D. J. (1999). Improvement in human tumour oxygenation with carbogen of varying carbon dioxide concentrations. Radiotherapy and Oncology, 50, 167–171. 10.1016/S0167-8140(98)00123-6 [DOI] [PubMed] [Google Scholar]
  88. Rampling, R. , Cruickshank, G. , Lewis, A. D. , Fitzsimmons, S. A. , & Workman, P. (1994). Direct measurement of pO2 distribution and bioreductive enzymes in human malignant brain tumors. International Journal of Radiation Oncology Biology Physics, 29(3), 427–431. 10.1016/0360-3016(94)90432-4 [DOI] [PubMed] [Google Scholar]
  89. Sakata, Y. S. , Grinberg, O. Y. , Grinberg, S. , Springett, R. , & Swartz, H. M. (2005). Simultaneous NIR‐EPR spectroscopy of rat brain oxygenation. Advances in Experimental Medicine and Biology, 566, 357–362. [DOI] [PubMed] [Google Scholar]
  90. Salyer, J. W. (2003). Neonatal and pediatric pulse oximetry. Respiratory Care, 48(4), 386–398. [PubMed] [Google Scholar]
  91. Scheeren, T. W. , Schober, P. , & Schwarte, L. A. (2012). Monitoring tissue oxygenation by near infrared spectroscopy (NIRS): Background and current applications. Journal of Clinical Monitoring and Computing, 26(4), 279–287. 10.1007/s10877-012-9348-y [DOI] [PMC free article] [PubMed] [Google Scholar]
  92. Scholz, M. , Cao, X. , Gunn, J. R. , Brůža, P. , & Pogue, B. W. (2020). pO2‐weighted imaging in vivo by delayed fluorescence of intracellular Protoporphyrin IX. Optics Letters, 45(2), 284–287. [DOI] [PubMed] [Google Scholar]
  93. Sealy, R. C. , Swartz, H. M. , & Olive, P. L. (1978). Electron spin resonance–spin trapping: Detection of superoxide formation during aerobic microsomal reduction of nitro‐compounds. Biochemical and Biophysical Research Communications, 82, 680–684. [DOI] [PubMed] [Google Scholar]
  94. Semenza, G. L. (1999). Regulation of mammalian O2 homeostasis by hypoxia‐inducible factor 1. Annual Review of Cell and Developmental Biology, 15, 551–578. [DOI] [PubMed] [Google Scholar]
  95. Semenza, G. L. (2000). Hypoxia, clonal selection and the role of HIF‐1 in tumor progression. Critical Reviews in Biochemistry and Molecular Biology, 35(2), 71–103. 10.1080/10409230091169186 [DOI] [PubMed] [Google Scholar]
  96. Spencer, J. A. , Ferraro, F. , Roussakis, E. , Klein, A. , Wu, J. , Runnels, J. M. , … Lin, C. P. (2014). Direct measurement of local oxygen concentration in the bone marrow of live animals. Nature, 508(7495), 269–273. 10.1038/nature13034 [DOI] [PMC free article] [PubMed] [Google Scholar]
  97. Springett, R. , & Swartz, H. M. (2007). Measurements of oxygen in vivo: Overview and perspectives on methods to measure oxygen within cells and tissues. Antioxidants & Redox Signaling, 9(8), 1295–1301. [DOI] [PubMed] [Google Scholar]
  98. Stewart, C. , Haitsma, I. , Zador, Z. , Hemphill, J. C. 3rd , Morabito, D. , Manley, G. 3rd , & Rosenthal, G. (2008). The new Licox combined brain tissue oxygen and brain temperature monitor: Assessment of in vitro accuracy and clinical experience in severe traumatic brain injury. Neurosurgery, 63(6), 1159–1164. discussion 1164–1165. [DOI] [PubMed] [Google Scholar]
  99. Stone, J. E. , Parker, R. , Gilks, C. B. , Stanbridge, E. J. , Liao, S. , & Aquino‐Parsons, C. (2005). Intratumoral oxygenation of invasive squamous cell carcinoma of the vulva is not correlated with regional node metastases. European Journal of Gynaecological Oncology, 26, 21–25. [PubMed] [Google Scholar]
  100. Sunar, U. , Quon, H. , Durduran, T. , Zhang, J. , Du, J. , Zhou, C. , … Yodh, A. G. (2006). Noninvasive diffuse optical measurement of blood flow and blood oxygenation for monitoring radiation therapy in patients with head and neck tumors: A pilot study. Journal of Biomedial Optics, 11(6), 064021. [DOI] [PubMed] [Google Scholar]
  101. Swartz, H. M. , Bennett, H. , Brown, R. D. III , Morse, P. D. II , Pals, M. , & Koenig, S. H. (1985). Feasibility of measuring oxygen and redox metabolism in vivo by NMR: Effect of paramagnetic materials and their cellular metabolism on relaxation times of protons of water and lipids. Period Biologorum, 87, 175–183. [Google Scholar]
  102. Swartz, H. M. , Flood, A. B. , Williams, B. B. , Pogue, B. W. , Schaner, P. E. , & Vaupel, P. (2020). What is the meaning of an oxygen measurement? Analysis of methods purporting to measure oxygen in targeted tissues. Advances in Experimental Medicine and Biology, 1269. (In press). [DOI] [PubMed] [Google Scholar]
  103. Swartz, H. M. , Vaupel, P. , Williams, B. B. , Schaner, P. E. , Gallez, B. , Schreiber, W. , … Flood, A. B. (2020). ‘Oxygen level in a tissue’ – What do available measurements really report? Advances in Experimental Medicine and Biology, 1232, 145–153. [DOI] [PubMed] [Google Scholar]
  104. Swartz, H. M. , Williams, B. B. , Zaki, B. I. , Hartford, A. C. , Jarvis, L. A. , Chen, E. Y. , … Kuppusamy, P. (2014). Clinical EPR: Unique opportunities and some challenges. Academic Radiology, 21(2), 197–206. 10.1016/j.acra.2013.10.011 [DOI] [PMC free article] [PubMed] [Google Scholar]
  105. Tatum, J. L. , Kelloff, G. J. , Gillies, R. , Arbeit, J. M. , Brown, J. M. , Chao, K. S. C. , … Sullivan, D. (2006). Hypoxia: Importance in tumor biology, noninvasive measurement by imaging, and value of its measurement in the management of cancer therapy. International Journal of Radiation Biology, 82(10), 699–757. 10.1080/09553000601002324 [DOI] [PubMed] [Google Scholar]
  106. Thulborn, K. R. , Waterton, J. C. , Matthews, P. M. , & Radda, G. K. (1982). Oxygenation dependence of the transverse relaxation time of water pro‐tons in whole blood at high field. Biochimica Et Biophysica Acta, 714, 265–270. 10.1016/0304-4165(82)90333-6 [DOI] [PubMed] [Google Scholar]
  107. Tran, L. B. , Bol, A. , Labar, D. , Jordan, B. , Magat, J. , Mignion, L. , … Gallez, B. (2012). Hypoxia imaging with the nitroimidazole 18F‐FAZA PET tracer: A comparison with OxyLite, EPR oximetry and 19F‐MRI relaxometry. Radiotherapy and Oncology, 105(1), 29–35. [DOI] [PubMed] [Google Scholar]
  108. User Manual . (2020). User manuals for Oxylite products. Retrieved from https://www.oxford‐optronix.com/support/supp_oxylite.htm
  109. Vaupel, P. (1994). Blood flow and metabolic microenvironment of brain tumors. Journal of Neuro‐oncology, 22(3), 261–267. 10.1007/BF01052931 [DOI] [PubMed] [Google Scholar]
  110. Vaupel, P. (2009). Pathophysiology of solid tumors In Molls M., Vaupel P., Nieder C., & Anscher M. S. (Eds.), The impact of tumor biology on cancer treatment and multidisciplinary strategies (pp. 51–92). Berlin, Heidelberg, New York: Springer. [Google Scholar]
  111. Vaupel, P. (2011). Pathophysiology of human tumors In Osinsky S., Friess H., & Vaupel P. (Eds.), Tumor hypoxia in the clinical setting (pp. 19–66). Kiev: Academperiodica. [Google Scholar]
  112. Vaupel, P. , & Harrison, L. (2004). Tumor hypoxia: Causative factors, compensatory mechanisms, and cellular response. The Oncologist, 9(Suppl 5), 4–9. [DOI] [PubMed] [Google Scholar]
  113. Vaupel, P. , Höckel, M. , & Mayer, A. (2007). Detection and characterization of tumor hypoxia using pO2 histography. Antioxidants & Redox Signaling, 9, 1221–1235. [DOI] [PubMed] [Google Scholar]
  114. Vaupel, P. , & Kelleher, D. K. (2013). Blood flow and oxygenation status of prostate cancers. Advances in Experimental Medicine and Biology, 765, 299–305. [DOI] [PubMed] [Google Scholar]
  115. Vaupel, P. , & Mayer, A. (2007). Hypoxia in cancer: Significance and impact on clinical outcome. Cancer and Metastasis Reviews, 26(2), 225–239. 10.1007/s10555-007-9055-1 [DOI] [PubMed] [Google Scholar]
  116. Vaupel, P. , & Mayer, A. (2014). Hypoxia in tumors: Pathogenesis‐related classification, characterization of hypoxia subtypes, and associated biological and clinical implications. Advances in Experimental Medicine and Biology, 812, 19–24. [DOI] [PubMed] [Google Scholar]
  117. Vaupel, P. , & Mayer, A. (2016). Tumor hypoxia: Causative mechanisms, microregional heterogeneities, and the role of tissue‐based hypoxia markers. Advances in Experimental Medicine and Biology, 923, 77–86. [DOI] [PubMed] [Google Scholar]
  118. Vaupel, P. , & Mayer, A. (2017a). Tumor oxygenation status: Facts and fallacies. Advances in Experimental Medicine and Biology, 977, 91–99. [DOI] [PubMed] [Google Scholar]
  119. Vaupel, P. , & Mayer, A. (2017b). Oxygenation of tumors In Schwab M. (Ed.), Encyclopedia of cancer (4th edn, pp. 3342–3346). Heidelberg: Springer Reference. [Google Scholar]
  120. Vaupel, P. , Mayer, A. , & Höckel, M. (2006). Oxygenation status of primary and recurrent squamous cell carcinomas of the vulva. European Journal of Gynaecological Oncology, 27, 142–146. [PubMed] [Google Scholar]
  121. Vaupel, P. , & Multhoff, G. (2020). The Warburg effect: Historical dogma vs. current rationale. Advances in Experimental Medicine and Biology, 1269. (in press). [DOI] [PubMed] [Google Scholar]
  122. Vaupel, P. , Schlenger, K. , Knoop, C. , & Höckel, M. (1991). Oxygenation of human tumors: Evaluation of tissue oxygen distribution in breast cancers by computerized O2 tension measurements. Cancer Research, 51, 3316–3322. [PubMed] [Google Scholar]
  123. Vaupel, P. , Schmidberger, H. , & Mayer, A. (2019). The Warburg effect: Essential part of metabolic reprogramming and central contributor to cancer progression. International Journal of Radiation Biology, 95(7), 912–919. 10.1080/09553002.2019.1589653 [DOI] [PubMed] [Google Scholar]
  124. Vaupel, P. , Thews, O. , Mayer, A. , Höckel, S. , & Höckel, M. (2002). Oxygenation status of gynecologic tumors: What is the optimal hemoglobin level? Strahlentherapie Und Onkologie, 178, 727–731. 10.1007/s00066-002-1081-x [DOI] [PubMed] [Google Scholar]
  125. Vaupel, P. , Wendling, P. , Thomé, H. , & Fischer, J. (1977). Respiratory gas exchange and glucose uptake by the human spleen in situ (Atemgaswechsel und Glucoseaufnahme der menschlichen Milz in situ). Klinische Wochenschrift, 55, 239–242. 10.1007/BF01487717 [DOI] [PubMed] [Google Scholar]
  126. Wen, B. , Urano, M. , Humm, J. L. , Seshan, V. E. , Li, G. C. , & Ling, C. C. (2008). Comparison of Helzel and OxyLite systems in the measurements of tumor partial oxygen pressure (pO2). Radiation Research, 169, 67–75. [DOI] [PMC free article] [PubMed] [Google Scholar]
  127. Wendling, P. , Vaupel, P. , Fischer, J. , & Brünner, H. (1977). Splenic respiratory gas exchange and glucose uptake in patients with splenomegaly in hypersplenism and Hodgkin's disease. Klinische Wochenschrift, 55, 1057–1061. 10.1007/BF01489480 [DOI] [PubMed] [Google Scholar]
  128. Wilson, D. F. , Harrison, D. K. , & Vinogradov, S. A. (2012). Oxygen, pH, and mitochondrial oxidative phosphorylation. Journal of Applied Physiology, 113(12), 1838–1845. 10.1152/japplphysiol.01160.2012 [DOI] [PubMed] [Google Scholar]
  129. Winbury, M. M. , Howe, B. B. , & Weiss, H. R. (1971). Effect of nitroglycerin and dipyridamole on epicardial and endocardial oxygen tension – Further evidence for redistribution of myocardial blood flow. Journal of Pharmacology and Experimental Therapeutics, 176, 184–199. [PubMed] [Google Scholar]
  130. Zhao, D. , Jiang, L. , & Mason, R. P. (2004). Measuring changes in tumor oxygenation. Methods in Enzymology, 386, 378–418. [DOI] [PubMed] [Google Scholar]
  131. Zhu, X.‐H. , & Chen, W. (2011). In vivo oxygen‐17 NMR for imaging brain oxygen metabolism at high field. Progress in Nuclear Magnetic Resonance Spectroscopy, 59(4), 319–335. 10.1016/j.pnmrs.2011.04.002 [DOI] [PMC free article] [PubMed] [Google Scholar]