Skip to main content
Jornal Brasileiro de Nefrologia logoLink to Jornal Brasileiro de Nefrologia
. 2020 Apr 27;42(2):147–152. doi: 10.1590/2175-8239-JBN-2019-0080

The influence of a doppler ultrasound in arteriovenous fistula for dialysis failure related to some risk factors

Influência da Ultrassonografia Doppler nas Falhas de Fístulas Arteriovenosas de Diálise Relacionada a Alguns Fatores de Risco

Jocefábia Reika Alves Lopes 1, Ana Lígia de Barros Marques 2, João Antonio Correa 1
PMCID: PMC7427647  PMID: 32353101

ABSTRACT

Introduction:

The increasing prevalence of chronic kidney disease has increased the demand for arteriovenous fistula (AVF) care. The objective of this study was to assess the relationship between some risk factors for AVF failure (advanced age, female sex, diabetes, obesity, central venous catheter, previous fistula, and hospitalization) and having a Doppler ultrasound performed preoperatively.

Methods:

A prospective study was performed with 228 dialysis patients from Imperatriz, Maranhão. Half of the sample was randomly selected to receive preoperative Doppler ultrasound and the other half did not, from the period of October 2016 to September 2018.

Results:

There were 53 total failures corresponding to 23.2% of our sample, which is almost double that of the patients in the clinical group. Considering the failures and risk factors associated with the overall sample, there was a statistically significant association between a central venous catheter on the same side of the AVF with P = 0.04 (Odds Ratio 1.24) and obesity with P = 0.05 (Odds Ratio 1.36), which was not repeated in the Doppler ultrasound group individually. There was no statistically significant difference between the Doppler group and clinical group with respect to the amount of days of previous AVF hospitalization and failure.

Conclusions:

We concluded that the reduction of failures with an introduction of the Doppler was statistically significant in the overall sample, but establishing a relationship between specific risk factors and failure was only possible with two of the risk factors in the study - obesity and central venous catheter on the same side of the AVF.

Keywords: Renal Insufficiency, Chronic; Renal Dialysis; Arteriovenous fistula; Ultrasonography, Doppler

INTRODUCTION

The increased prevalence of chronic kidney disease (CKD) and consequent economic impacts on health services has resulted in a higher demand for arteriovenous fistula (AVF) care, which is considered to be the Achilles’ heel of hemodialysis.1 The Doppler ultrasound is a non-invasive method that enables safe structural and functional access to peripheral vessels, and is becoming the preferred image mode for AVF construction and follow-up.1 - 10

The Brazilian Society of Nephrology’s 2018 census data estimate 133,464 CKD dialysis patients in Brazil that year with the national prevalence being 640 pmp (patients per million population) and 276 pmp in Maranhão. The vast majority (92.3%) of dialysis patients are in hemodialysis.11

The autogenous arteriovenous fistula in the wrist has been the first choice for most surgeons, as it is the radio-cephalic fistula originally described by Brescia-Cimino in 1966 and still offers the least risk of complications as well as good durability.12 , 13 Grafts or catheters present a lower survival rate due to a higher incidence of thrombosis and occlusion by intimal hyperplasia, in addition to an increased susceptibility to infections, leading to greater patient morbimortality when compared with an autogenous arteriovenous fistula.14

According to the National Kidney Foundation - Kidney Disease Outcomes Quality Initiative (NKF-K/DOQI), an ideal access provides adequate flow rate, good durability, and has a low rate of complications (such as infection, stenosis, thrombosis, aneurysm, and limb ischemia). Among existing accesses, arteriovenous fistulas are the closest to ideal.15 Certain studies have shown an initial maturation rate to be unsatisfactory, with 30% to 60% failure in maturation.16 , 17

The Doppler ultrasound helps vascular surgeons plan the most suitable fistula configuration to optimize the rate of blood flow in the vascular access for hemodialysis, potentially reducing the incidence of arteriovenous fistulas dysfunction.6 , 18

The NKF-DOQI and the Society for Vascular Surgery’s Guidelines recommend image vessel mapping for all patients undergoing arteriovenous fistula for hemodialysis surgery.15 , 19

The use and interpretation of venous mapping for a preoperative Doppler ultrasound of AVFs vary considerably depending on the country, with high usage shown in the United States, regardless of patient characteristics. Canadian and European surgeons selectively use vessel mapping in patients with a BMI > 30, prior surgical access, history of central venous catheter use, and PICC - Peripherally Inserted Central Catheter.20

Our prospective study sought to analyze the relationship between risk factors for arteriovenous fistula failure (advanced age, female sex, diabetes, obesity, central venous catheter on the same side of the AVF, prior fistula, and performing the fistula soon after hospitalization) and having a Doppler ultrasound performed preoperatively.

METHODS

The study was approved by the ABC-SP School of Medicine’s Ethics Committee (FMABC-SP) and is in accordance with the Declaration of Helsinki; all participants signed the informed consent form. This was a prospective study with dialysis patients from the hemodialysis clinics of Imperatriz-Maranhão (Clinic for Renal Disease and Imperatriz Nephrology Clinic) who provide services for the SUS (Unified Health System). The sample size was 228 patients. Half were randomly selected by a simple 1:1 draw to perform preoperative AVF Doppler ultrasound and the other half did not use this preoperative method and were only evaluated by physical examination. We evaluated the possible reduction of AVF failures associated with the following risk factors - advanced age, female sex, diabetes, obesity, central venous catheter on the same side as the AVF, previous fistula, and hospitalization close to AVF execution - and the use of Doppler. The study occurred from October 2016 to September 2018 with each patient being followed for 6 months (in the immediate postoperative period, at 1 week, 3 months, and 6 months).

The inclusion criteria were adult patients (age > 18 years) with a stable clinical condition, patent palmar arch (Allen test), and study authorization, luminal vessel diameter as described below, absence of stenosis or thrombosis in the central venous system, and absence of stenosis or arterial occlusion evaluated by Doppler ultrasound (ultrasound group). The exclusion criterion was patients who had the Doppler performed privately.

The ultrasound machine used was the HD11 XE Performance Plus® (Philips) with transducer from 3 to 12 MHz, and the examination was performed by a single vascular sonographer. All patients were examined in a seated position, with their arms resting on the examination table. The scanning of superficial veins was performed with the use of a tourniquet. The compressibility of the cephalic and basilic veins across their path to B-mode, as well as the diameters of these veins were measured with a transverse section at the wrist, proximal 1/3 of the forearm, and distal and proximal 1/3 of the arm. The continuity of the deep venous system to the axillary and subclavian veins was evaluated. We investigated the diameter and flow of brachial, ulnar, and radial arteries, as well as subclavian and axillary arteries to evaluate possible stenosis. Patency of the palmar arch was evaluated via Allen test. The evaluation of the dominant arm was only performed when the non-dominant presented an unsatisfactory assessment.

In this study, the vessels met the minimum criteria of venous luminal diameter ≥ 2.5 mm for native fistulas (using tourniquet), axillary vein diameter ≥ 4.0 mm for arteriovenous grafts, and arterial luminal diameter ≥ 2.0 mm to be used in AVF implementation.21

Physical examination of the clinical group was performed by a vascular surgeon who constructed the AVFs. The veins were assessed with a tourniquet for diameter and compressibility, and edema or collateral circulation were evaluated in the arm with sign of central venous stenosis. The arterial segment was evaluated for pulsatility and Allen’s test.

The professional team consisted of 3 experienced vascular surgeons who provided their services to the SUS. Each surgeon performed the same amount of surgeries in both groups.

The AVF locations were mostly distal than proximal and in the non-dominant arm whenever possible. A prosthetic graft was used only when there was no native vein for AVF completion. When the AVF was performed, the surgeon evaluated the presence or absence of a thrill; however, nephrologists and skilled nurses clinically evaluated the AVF maturation. The AVFs and possible alterations were followed by 6 months. There was no endovascular procedure for fistula rescue performed in this study.

DATA ANALYSIS

The collected data was stored in a Microsoft Excel 2016 spreadsheet. After checking for errors and inconsistencies, descriptive examinations were performed by means of absolute and relative frequencies and measures of central tendency and variability.

The chi-square test, or equivalent, was used to assess associations between qualitative variables, and in the case of significant 2x2 associations, odds ratios and confidence intervals were calculated by means of logistic regression. For the analysis of quantitative variables, a Student’s t-test or similar non-parametric method was used. All examinations were performed at 5% significance level using the IBM SPSS® program (IBM SPSS Statistics, Version 24.0, 2016).

RESULTS

The main etiology of CKD was hypertension in both groups accompanied by diabetes, together corresponding to 90% of the causes of renal disease. Dominating factors were male sex, 60% of the cases, and age below 65 years, 78%, as shown in Table 1.

Table 1. Basic characteristics (n=228).

Characteristics   Percentage
Gender Male 60%
Female 40%
Age < 65 years 78%
≥ 65 years 22%
Etiology Hypertension 50%
Diabetes 40%
Lupus 2.2%
Multiple myeloma 0.9%
Polycystic kidney disease 1.7%
Unknown 2.6%
Chronic glomerulonephritis 0.9%
Other 1.7%
Diabetes Yes 50.9%
No 49.1%
Obesity Yes 6.1%
No 93.9%
Central venous catheter Yes 15.8%
No 84.2%
Prior AVF Yes 36%
No 64%

The data are presented as absolute frequency.

There were a total of 53 failures, corresponding to 23.2% of the total. Most (76%) occurred without effective use of the fistula (during negative exploration, immediate failure, and early thrombosis prior to maturity). In addition, 34% occurred in the ultrasound group, in contrast with 66% in the clinical group, as shown in Table 2.

Table 2. AVF failures (n=228).

Failures Percentage P-value
Clinical Group 66%  
Doppler Group 34%  
Early (Before maturation) 75.5% 0.02
Late (After maturation) 24.5%  

P-value of the Chi-squared test.

Considering the failures and risk factors associated with the overall sample (with and without Doppler), there was only significant association between having central venous catheter on the same side of the arteriovenous fistula with P = 0.04 (odds ratio of 1.24) and obesity with P = 0.05 (odds ratio of 1.36), as shown in Table 3. However, the Doppler group did not show significant association with any risk factor for failure, as set forth in Table 4.

Table 3. Correlation between failure and risk factors (n=228).

  Failure Odds Ratio [95%CI]
No Yes P-value*
Gender Female 68 (73.9%) 24 (26.1%) 0.40 -
Male 107 (78.7%) 29 (21.3%) -
Age < 65 years 136 (76.4%) 42 (23.6%) 0.81 -
≥ 65 years 39 (78.0%) 11 (22.0%) -
Diabetes No 86 (76.8%) 26 (23.2%) 0.99 -
Yes 89 (76.7%) 27 (23.3%) -
Obesity No 167 (78.0%) 47 (22.0%) 0.05 Ref
Yes 8 (57.1%) 6 (42.9%) 1.36 [1.01 – 2.16]
Central catheter No 152 (79.2%) 40 (20.8%) 0.04 Ref
Yes 23 (63.9%) 13 (36.1%) 1.24 [1.02 – 1.60]
Previous No 110 (75.3%) 36 (24.7%) 0.50 -
AVF Yes 65 (79.3%) 17 (20.7%)   -
*

P-value of the Chi-square test.

Table 4. Ultrasound group: correlation between failure and risk factors (n=114).

  Failure P-value
No Yes
Gender Female 42 (85.7%) 7 (14.3%) 0.70*
Male 54 (83.1%) 11 (16.9%)
Age < 65 years 74 (82.2%) 16 (17.8%) 0.36**
≥ 65 years 22 (91.7%) 2 (8.3%)
Diabetes No 45 (81.8%) 10 (18.2%) 0.50*
Yes 51 (86.4%) 8 (13.6%)
Obesity No 91 (85.0%) 16 (15.0%) 0.31**
Yes 5 (71.4%) 2 (28.6%)
Central catheter No 82 (83.7%) 16 (16.3%) 0.70**
Yes 14 (87.5%) 2 (12.5%)
Previous AVF No 63 (79.7%) 16 (20.3%) 0.06**
Yes 33 (94.3%) 2 (5.7%)
*

Chi-square test.

**

Fisher Test.

Table 5 shows the Doppler data with the venous diameters and depths, as well as arterial diameters, considering that the venous inclusion criteria were a diameter of ≥ 2.5 mm, arterial of ≥ 2.0 mm, and axillary of ≥ 4.0 mm. Independent of the depth of the basilic vein in the upper arm, it was transposed anteriorly in all patients of the two groups.

Table 5. Means and standard deviation in the preoperative ultrasound mapping group (n=114).

Doppler Ultrasound   MEAN SD
Cephalic vein (n=78) Diameter (cm) 0.37 0.08
Depth (cm) 0.19 0.09
Basilic vein (n=23) Diameter (cm) 0.40 0.11
Depth (cm) 0.64 0.31
Axillary vein (n=13) Diameter (cm) 0.69 0.14
Radial artery (n=29) Diameter (cm) 0.23 0.03
PSV (cm/sec) 52.93 17.50
Brachial artery (n=85) Diameter (cm) 0.39 0.09
PSV (cm/sec) 68.00 21.27

SD: standard deviation.

No significant correlation was observed between number of hospitalization days and failure rate in both groups and there was no difference in hospitalization time between the Doppler and clinical group, as shown in Table 6.

Table 6. Number of days hospitalized as per group and failure rate of patients undergoing AVF (n=228).

Days hospitalized (Mean ± Standard Deviation) p *
Group Clinical (n=114) 8.91±13.40 0.052
Clinical (n=114) 10.98±14.34
Failures Yes (n=53) 9.34±13.58 0.29
No (n=175) 11.94±14.80
*

Nonparametric Wilcoxon-Mann-Whitney U test.

DISCUSSION

In our trial, hypertension was the main cause of CKD followed by diabetes, and showed predominance in males, which is in agreement with several other studies.2 , 11 , 22 - 27 Compared to previous studies, we found a slightly lower failure rate.22 , 28 - 30

We found no statistically significant association between fistula failures and risk factors such as advanced age, female gender, and diabetes, as reported in some studies.24 , 31 - 36 However, despite our initial sample of 228 patients, failure occurred in only 53 cases, reducing our sample for association analysis, which might explain the lack of association as suggested by the studies cited above.

In the overall sample, patients with obesity were 1.36 times more likely to experience failure than the non-obese; those with a central catheter were 1.24 times more likely to experience failure than those who without. In the Doppler ultrasound group, there was no significant association with a central catheter or obesity, which suggests that the Doppler provides for a reduction of failures in these patients.

There was no difference between the number of days of hospitalization between the groups who experienced failures or not (p=0.29), and there was no difference between the number of days of hospitalization among the clinical and ultrasound groups (p=0.052). This shows that both the physical examination and the Doppler ultrasound were able to identify the veins damaged by possible punctures before the AVF. We did not find similar data in the literature for comparison.

CONCLUSION

We conclude that the reduction of failure rate with the use of the Doppler was statistically significant in the overall sample; nonetheless, establishing a relationship between specific risk factors and failures was only possible with two risk factors - obesity and a central venous catheter on the same side of the AVF. This shows the benefit of preoperative use of Doppler in AVFs, mainly to reduce failures related to these two risk factors. Further studies with larger sample sizes are recommended.

REFERENCES

  • 1.Shenoy S, Darcy M. Ultrasound as a tool for preoperative planning, monitoring, and interventions in dialysis arteriovenous access. AJR Am J Roentgenol. 2013 Oct;201(4):W539–W543. doi: 10.2214/AJR.13.11277. [DOI] [PubMed] [Google Scholar]
  • 2.Ilhan G, Esi E, Bozok S, Yurekli I, Ozpak B, Ozelci A, et al. The clinical utility of vascular mapping with Doppler ultrasound prior to arteriovenous fistula construction for hemodialysis access. J Vasc Access. 2013 Jan-Mar;14(1):83–88. doi: 10.5301/jva.5000097. [DOI] [PubMed] [Google Scholar]
  • 3.Lok CE, Davidson I. Optimal choice of dialysis access for chronic kidney disease patients: developing a life plan for dialysis access. Semin Nephrol. 2012 Nov;32(6):530–537. doi: 10.1016/j.semnephrol.2012.10.003. [DOI] [PubMed] [Google Scholar]
  • 4.Marques MG, Ibeas J, Botelho C, Maia P, Ponce P. Doppler ultrasound: a powerful tool for vascular access surveillance. Semin Dial. 2015 Mar-Apr;28(2):206–210. doi: 10.1111/sdi.12334. [DOI] [PubMed] [Google Scholar]
  • 5.Lomonte C, Meola M, Petrucci I, Casucci F, Basile C. The key role of color Doppler ultrasound in the work-up of hemodialysis vascular access. Semin Dial. 2015 Mar-Apr;28(2):211–215. doi: 10.1111/sdi.12312. [DOI] [PubMed] [Google Scholar]
  • 6.Dageforde LA, Harms KA, Feurer ID, Shaffer D. Increased minimum vein diameter on preoperative mapping with duplex ultrasound is associated with arteriovenous fistula maturation and secondary patency. J Vasc Surg. 2015 Jan;61(1):170–176. doi: 10.1016/j.jvs.2014.06.092. [DOI] [PubMed] [Google Scholar]
  • 7.Bandyk DF. Interpretation of duplex ultrasound dialysis access testing. Semin Vasc Surg. 2013 Jun-Sep;26(2-3):120–126. doi: 10.1053/j.semvascsurg.2013.12.001. [DOI] [PubMed] [Google Scholar]
  • 8.Mudoni A, Caccetta F, Caroppo M, Musio F, Accogli A, Zacheo MD, et al. Echo color Doppler ultrasound: a valuable diagnostic tool in the assessment of arteriovenous fistula in hemodialysis patients. J Vasc Access. 2016 Sep;17(5):446–452. doi: 10.5301/jva.5000588. [DOI] [PubMed] [Google Scholar]
  • 9.Pajek J, Malovrh M. Preoperative ultrasound still valuable for radio-cephalic arteriovenous fistula creation. J Vasc Access. 2017;18(Suppl 1):5–9. doi: 10.5301/jva.5000672. [DOI] [PubMed] [Google Scholar]
  • 10.Marques MG, Ponce P. Pre-operative assessment for arteriovenous fistula placement for dialysis. Semin Dial. 2017 Jan;30(1):58–62. doi: 10.1111/sdi.12561. [DOI] [PubMed] [Google Scholar]
  • 11.Sociedade Brasileira de Nefrologia (SBN) Censo SBN - 2018. São Paulo: SBN; 2018. Available from: https://sbn.org.br/censo-2018. [Google Scholar]
  • 12.Clark TW, Cohen RA, Kwak A, Markmann JF, Stavropoulos SW, Patel AA, et al. Salvage of nonmaturing native fistulas by using angioplasty. Radiology. 2007;242(1):286–292. doi: 10.1148/radiol.2421051718. [DOI] [PubMed] [Google Scholar]
  • 13.Wiese P, Nonnast-Daniel B. Colour Doppler ultrasound in dialysis access. Nephrol Dial Transplant. 2004 Aug;19(8):1956–1963. doi: 10.1093/ndt/gfh244. [DOI] [PubMed] [Google Scholar]
  • 14.Duval L. Proximal radial artery arteriovenous fistulae (PRA-AVF) Nephrol Nurs J. 2007 Mar-Apr;34(2):217–218. [PubMed] [Google Scholar]
  • 15.Vascular Access 2006 Work Group Clinical practice guidelines for vascular access. Am J Kidney Dis. 2006 Jul;48(Suppl 1):S176–S247. doi: 10.1053/j.ajkd.2006.04.029. [DOI] [PubMed] [Google Scholar]
  • 16.Biuckians A, Scott EC, Meier GH, Panneton JM, Glickman MH. The natural history of autologous fistulas as first-time dialysis access in the KDOQI era. J Vasc Surg. 2008;47(2):415–421. doi: 10.1016/j.jvs.2007.10.041. discussion:420-1. [DOI] [PubMed] [Google Scholar]
  • 17.Dember LM, Beck GJ, Allon M, Delmez JA, Dixon BS, Greenberg A, et al. Effect of clopidogrel on early failure of arteriovenous fistulas for hemodialysis: a randomized controlled trial. JAMA. 2008 May;299(18):2164–2171. doi: 10.1001/jama.299.18.2164. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Caroli A, Manini S, Antiga L, Passera K, Ene-Iordache B, Rota S, et al. Validation of a patient-specific hemodynamic computational model for surgical planning of vascular access in hemodialysis patients. Kidney Int. 2013 Dec;84(6):1237–1245. doi: 10.1038/ki.2013.188. [DOI] [PubMed] [Google Scholar]
  • 19.Sidawy AN, Spergel LM, Besarab A, Allon M, Jennings WC, Padberg FT, Junior, et al. The Society for Vascular Surgery: clinical practice guidelines for the surgical placement and maintenance of arteriovenous hemodialysis access. J Vasc Surg. 2008 Nov;48(5 Suppl):2S–25S. doi: 10.1016/j.jvs.2008.08.042. [DOI] [PubMed] [Google Scholar]
  • 20.Nica A, Lok CE, Harris J, Lee TC, Mokrzycki MH, Maya ID, et al. Understanding surgical preference and practice in hemodialysis vascular access creation. Semin Dial. 2013 Jul-Aug;26(4):520–526. doi: 10.1111/sdi.12046. [DOI] [PubMed] [Google Scholar]
  • 21.Silva MB, Junior, Hobson RW, Pappas PJ, Jamil Z, Araki CT, Goldberg MC, et al. A strategy for increasing use of autogenous hemodialysis access procedures: impact of preoperative noninvasive evaluation. J Vasc Surg. 1998 Feb;27(2):302–307. doi: 10.1016/s0741-5214(98)70360-x. discussion:307-8. [DOI] [PubMed] [Google Scholar]
  • 22.Ferring M, Claridge M, Smith SA, Wilmink T. Routine preoperative vascular ultrasound improves patency and use of arteriovenous fistulas for hemodialysis: a randomized trial. Clin J Am Soc Nephrol. 2010 Dec;5(12):2236–2244. doi: 10.2215/CJN.02820310. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Nursal TZ, Oguzkurt L, Tercan F, Torer N, Noyan T, Karakayali H, et al. Is routine preoperative ultrasonographic mapping for arteriovenous fistula creation necessary in patients with favorable physical examination findings? Results of a randomized controlled trial. World J Surg. 2006 Jun;30(6):1100–1107. doi: 10.1007/s00268-005-0586-8. [DOI] [PubMed] [Google Scholar]
  • 24.Jemcov TK. Morphologic and functional vessels characteristics assessed by ultrasonography for prediction of radiocephalic fistula maturation. J Vasc Access. 2013 Oct-Dec;14(4):356–363. doi: 10.5301/jva.5000163. [DOI] [PubMed] [Google Scholar]
  • 25.Han A, Min SK, Kim MS, Joo KW, Kim J, Ha J, et al. A prospective, randomized trial of routine duplex ultrasound surveillance on arteriovenous fistula maturation. Clin J Am Soc Nephrol. 2016 Oct;11(10):1817–1824. doi: 10.2215/CJN.00620116. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Itoga NK, Ullery BW, Tran K, Lee GK, Aalami OO, Bech FR, et al. Use of a proactive duplex ultrasound protocol for hemodialysis access. J Vasc Surg. 2016 Oct;64(4):1042–1049. doi: 10.1016/j.jvs.2016.03.442. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Olsha O, Hijazi J, Goldin I, Shemesh D. Vascular access in hemodialysis patients older than 80 years. J Vasc Surg. 2015 Jan;61(1):177–183. doi: 10.1016/j.jvs.2014.07.005. [DOI] [PubMed] [Google Scholar]
  • 28.Smith GE, Barnes R, Chetter IC. Randomized clinical trial of selective versus routine preoperative duplex ultrasound imaging before arteriovenous fistula surgery. Br J Surg. 2014 Apr;101(5):469–474. doi: 10.1002/bjs.9435. [DOI] [PubMed] [Google Scholar]
  • 29.Barreto P, Almeida P, Matos N, Queiros JA, Pinheiro J, Silva F, et al. Preoperative vessel mapping in chronic kidney disease patients - a center experience. J Vasc Access. 2016;17(4):320–327. doi: 10.5301/jva.5000559. [DOI] [PubMed] [Google Scholar]
  • 30.Al-Jaishi AA, Oliver MJ, Thomas SM, Lok CE, Zhang JC, Garg AX, et al. Patency rates of the arteriovenous fistula for hemodialysis: a systematic review and meta-analysis. Am J Kidney Dis. 2014 Mar;63(3):464–478. doi: 10.1053/j.ajkd.2013.08.023. [DOI] [PubMed] [Google Scholar]
  • 31.Lok CE, Allon M, Moist L, Oliver MJ, Shah H, Zimmerman D. Risk equation determining unsuccessful cannulation events and failure to maturation in arteriovenous fistulas (REDUCE FTM I) J Am Soc Nephrol. 2006 Nov;17(11):3204–3212. doi: 10.1681/ASN.2006030190. [DOI] [PubMed] [Google Scholar]
  • 32.Wang W, Murphy B, Yilmaz S, Tonelli M, Macrae J, Manns BJ. Comorbidities do not influence primary fistula success in incident hemodialysis patients: a prospective study. Clin J Am Soc Nephrol. 2008 Jan;3(1):78–84. doi: 10.2215/CJN.00370107. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Ortega T, Ortega F, Diaz-Corte C, Rebollo P, Ma Baltar J, Alvarez-Grande J. The timely construction of arteriovenous fistulae: a key to reducing morbidity and mortality and to improving cost management. Nephrol Dial Transplant. 2005 Mar;20(3):598–603. doi: 10.1093/ndt/gfh644. [DOI] [PubMed] [Google Scholar]
  • 34.Mousa AY, Dearing DD, Aburahma AF. Radiocephalic fistula: review and update. Ann Vasc Surg. 2013;27(3):370–378. doi: 10.1016/j.avsg.2012.07.012. [DOI] [PubMed] [Google Scholar]
  • 35.O'Banion LA, Van Buren D, Davis JW. Radiocephalic fistulas for hemodialysis: a comparison of techniques. Am Surg. 2015 Apr;81(4):341–344. doi: 10.1177/000313481508100421. [DOI] [PubMed] [Google Scholar]
  • 36.Cheng Q, Zhao YJ. The reasons for the failure of the primary arteriovenous fistula surgery in patients with end-stage renal disease. J Vasc Access. 2015;(16) Suppl 10:S74–S77. doi: 10.5301/jva.5000424. [DOI] [PubMed] [Google Scholar]

Articles from Jornal Brasileiro de Nefrologia are provided here courtesy of Sociedade Brasileira de Nefrologia

RESOURCES