Table 3.
Calculated energy needs | |
---|---|
Total nominal power (kWe) | 45,740 |
Annual energy consumption (GWh/y) | 380 |
Specific energy consumption (kWh/m3) | 4.0 |
Calculated technical details of RO plant | |
---|---|
Number of trains | 16 |
Number of pressure vessels/train | 150 |
Number of membrane elements/pressure vessel | 7 |
Total number of membrane elementsa | 16,800 |
Energy recovery devicesb | 220 |
Feed pressure (bar) | 64 |
Conversion rate | 43.5% |
The standard membrane surface for each membrane element is 37,15 m2.
The energy recovery device based on pressure exchanger is based on ERI PX300 model.