Skip to main content
PLOS ONE logoLink to PLOS ONE
. 2020 Aug 19;15(8):e0236439. doi: 10.1371/journal.pone.0236439

Extracellular vesicles from human plasma and serum are carriers of extravesicular cargo—Implications for biomarker discovery

Mari Palviainen 1,2,3, Mayank Saraswat 4,5, Zoltán Varga 6, Diána Kitka 6, Maarit Neuvonen 1,2,3, Maija Puhka 2,7, Sakari Joenväärä 4,5, Risto Renkonen 4,5, Rienk Nieuwland 8,9, Maarit Takatalo 1,2,3, Pia R M Siljander 1,2,3,*
Editor: John Matthew Koomen10
PMCID: PMC7446890  PMID: 32813744

Abstract

Extracellular vesicles (EVs) in human blood are a potential source of biomarkers. To which extent anticoagulation affects their concentration, cellular origin and protein composition is largely unexplored. To study this, blood from 23 healthy subjects was collected in acid citrate dextrose (ACD), citrate or EDTA, or without anticoagulation to obtain serum. EVs were isolated by ultracentrifugation or by size-exclusion chromatography (SEC) for fluorescence-SEC. EVs were analyzed by micro flow cytometry, NTA, TEM, Western blot, and protein mass spectrometry. The plasma EV concentration was unaffected by anticoagulants, but serum contained more platelet EVs. The protein composition of plasma EVs differed between anticoagulants, and between plasma and serum. Comparison to other studies further revealed that the shared EV protein composition resembles the “protein corona” of synthetic nanoparticles incubated in plasma or serum. In conclusion, we have validated a higher concentration of platelet EVs in serum than plasma by contemporary EV methods. Anticoagulation should be carefully described (i) to enable study comparison, (ii) to utilize available sample cohorts, and (iii) when preparing/selecting biobank samples. Further, the similarity of the EV protein corona and that of nanoparticles implicates that EVs carry both intravesicular and extravesicular cargo, which will expand their applicability for biomarker discovery.

Introduction

Biomarkers are sought as measurable indicators of pathological processes and for treatment monitoring. Extracellular vesicles (EVs) contain a rich and multifaceted cargo of proteins, metabolites, lipids and nucleic acids for biomarker discovery, and therefore EVs are an excellent source of potential biomarkers. Although EVs can be isolated from all body fluids and from tissues, blood provides the richest source of EVs. Blood-borne EVs are a heterogeneous population originating from blood cells, endothelial cells, and for example in cancer patients from tumor cells [1]. Therefore, blood EVs may well serve as biomarkers of multiple diseases, either by their concentration or by a selection of molecules derived from their biochemical composition. So far, the majority of EV biomarker studies have concentrated on the discovery of cancer biomarkers [2], closely followed by biomarkers for cardiovascular diseases [3]. Plasma and serum samples offer in the form of liquid biopsy a relatively non-invasive means to detect disease-related biomarkers making them an optimal target for studies using large study cohorts and biobanks. Unfortunately, most of the currently available biobank samples have not been collected with EVs in mind. Although some confounders of sample uniformity such as anticoagulation, agitation and delay in processing (causing ex vivo platelet activation followed by vesiculation) are becoming better acknowledged, currently many preanalytical steps remain unaddressed in a systematic way [4, 5]. Recently, the International Society of Extracellular Vesicles (ISEV) standardization taskforce has realized the urgency of standardizing blood sample collection and generated harmonization initiatives for the field [6].

So far, only a few studies have addressed the effect of anticoagulation–or its absence i.e. serum—on the resulting EV population. The seminal study of George et al. demonstrated that the concentration of “platelet microparticles”, isolated by centrifugation at 35 000 x g, were higher in serum than in plasma anticoagulated by acid citrate dextrose (ACD), which was attributed to platelet activation during clot formation [7]. In the study of György et al., ACD was shown to be superior in comparison to citrate in preventing artefactual platelet activation and vesiculation during blood collection [5]. However, there are no studies yet on the effect of anticoagulants on the molecular composition of blood-borne EVs. Therefore, we studied EVs isolated from blood anticoagulated with the three most commonly used anticoagulants and serum by contemporary EV analytics and following the latest recommendations regarding blood handling [6, 8].

In pharmaceutics, nanoparticles (NPs) are developed for drug delivery solutions (DDS). Due to their fast elimination from the body, synthetic NP and their protein corona have recently been under intensive investigation [911]. In addition to DDS applications, NP corona has also been suggested to be a future diagnostic tool for e.g. cancer diagnostics [1214]. Previous studies have shown that the protein corona of NPs can be divided into a hard and a soft part, depending on the binding affinities of the associating proteins [1517]. Proteins that bind directly to the surface of the NPs with high affinity, are considered to constitute the hard corona, and proteins that bind to other proteins via weak protein-protein interactions, constitute the soft corona [18]. The corona of various NPs has been studied in detail, and a shared “core”proteome has been established, which comprises lipoproteins, complement and coagulation proteins, and immunoglobulins [1922]. In the present study we compared our proteomics results to NP protein corona studies.

Materials and methods

Preparation of plasma and serum

Blood samples were obtained from healthy, fasting volunteers and collected into ACD-A (Vacuette #455055, Greiner Bio-One, Kremsmünster, Austria), citrate (Vacuette #455322, Greiner Bio-One), serum (BD #369032, BD Biosciences, Franklin Lakes, USA) and EDTA (K2F, BD #368861, BD Biosciences) tubes by a protocol approved by the ethical board of University of Helsinki. Volunteers had not used any medication for the previous 7 days and their informed consent was obtained according to the declaration of Helsinki. Study samples were collected twice in Helsinki (set I and II) and once in Budapest (set III), the latter to perform fluorescence size exclusion chromatography (Flu-SEC). The average age of the donors in set I was 45 years (range 27–55), 32 years (range 18–51 years) in set II, and 30 years (range 25–36) in set III. Majority of the volunteers were females (80%, 70%, and 67%). Serum, and ACD, citrate and EDTA plasma were obtained during the same blood collection, 2 x 4 mL or 10 mL for each plasma/serum type using 18G needle and tourniquet that was released immediately after the venipuncture, followed by gentle end-over-end mixing 10 times. Blood samples were processed within 30 minutes of sampling to obtain plasma, while serum was allowed to clot for 30 minutes at room temperature (RT) prior centrifugation. Samples for set I and II were centrifuged twice at 2500 × g for 15 minutes at RT (5804R, Eppendorf AG, Hamburg, Germany). For the set III, platelet-free plasma and serum was prepared by centrifuging twice at 2500 × g for 15 minutes at RT (NF 800R, RA 200 swing-out rotor, Nüve, Ankara, Turkey). For the sample sets I and II, equal volumes of individual donors’ plasma/serum were combined into a pool of each anticoagulant and serum after the second centrifugation. Pooled plasma/serum samples were analyzed with Coulter T-540 counter (version 3F, Beckman Coulter, Brea, USA) for remnant cell counts, and used for experiments directly without freezing. For the set III, individual donors’ samples were kept separate for the Flu-SEC analysis. The details of the workflow are provided in a (S1 Table).

Isolation of EVs

EVs from set I and II were isolated by ultracentrifugation as follows: pooled plasma (ACD, citrate and EDTA), and serum samples were diluted 1:1 with PBS and centrifuged at 110 000 × gmax for 90 minutes at 4˚C (k-factor 190.2, Type 50.2 Ti, Optima-LE 80K, Beckman Coulter). The supernatant was discarded, and the pellets were resuspended in 20 mL PBS followed by re-centrifugation. The final pellet was suspended in 250 μl PBS, aliquoted to Protein LoBind Tubes (Eppendorf AG) and stored at 4˚C overnight for further analysis, except for TEM and proteomics for which samples were frozen at -80˚C. For the set III, platelet-free plasma and serum were purified by SEC on a 3.5 mL gravity column filled with Sepharose CL-2B gel (GE Healthcare Bio-Sciences AB, Uppsala, Sweden). One mL platelet-free plasma/serum was loaded on the column, the flow through was discarded and purified EVs were eluted with 1 mL PBS buffer.

We have submitted all relevant data of our experiments to the EV-TRACK knowledgebase [23] (http://evtrack.org/, ID: EV190060).

Flow cytometry analysis

Apogee A50 micro flow cytometer (ApogeeFlow, Hertfordshire, UK) equipped with 405 nm and 488 nm lasers and 525/50 and 575/30 filters was used for measuring EVs. Logarithmic scale and peak height were used. Event level below 100 events/s with 1.5 μL/minute flow rate and 150 mbar pressure was considered acceptable for background. Three washing cycles were performed between the samples. Flow rate was adjusted between 1.5–4.5 μL/minute to keep average event rates below 3000 events/s. All isolated EV samples were diluted 1:20 to obtain ~1*109 particles/mL and 50 μL was labelled (in technical triplicates) with anti- CD61-PE (clone VI-PL2, BD Biosciences, 1:25) and anti-CD235a-FITC (clone 11E4B-7-6, BD Biosciences, 1:25), matching isotype antibodies at same dilutions, or with Annexin V–Alexa488 (Invitrogen, Carlsbad, USA, 1:20) in the presence of 5 mM CaCl2. Labelling was done for 1 hour at room temperature in the dark. Before analysis, the isolated EV samples were further diluted 1:5. Statistical analysis was conducted using Tukey´s multiple comparison test.

Size exclusion chromatography with on-line fluorescence detection (Flu-SEC)

Flu-SEC was used to quantify the amount of platelet-derived (CD61+) EVs in serum, and ACD-, citrate- and EDTA-plasma as described earlier [24]. EVs were separated from soluble proteins with the Sepharose CL-2B cross-linked agarose gel (GE Healthcare Bio-Sciences AB). Four μL anti-CD61-PE (clone VI-PL2, 6 μg/mL, BioLegend, USA) was used to label platelet-derived EVs (technical triplicates) in 100 μL of SEC-isolated plasma/serum. Labelling was performed for 30 minutes at 37 ˚C. Ten μL of labeled sample was injected into a Jasco HPLC system (Jasco, Tokyo, Japan) consisting of a PU-2089 pump with a UV-2075 UV/Vis detector and a FP-2020 fluorescence detector controlled by the Chromnav software v. 1.17.02. Tricorn 5/200 glass columns (GE Healthcare Bio-Sciences AB) were packed with Sepharose CL-2B (GE Healthcare Bio-Sciences AB), and the eluent of 1 ml of PBS with a flow rate of 0.5 mL/minute. The fluorescence chromatograms were collected at excitation and emission wavelength corresponding to PE fluorochrome (565/578 nm), and the area under the curve (AUC) of the EV-peak was used to quantify the amount of platelet-derived EVs in the various plasma and serum samples. Statistical analysis was conducted using Tukey´s multiple comparison test.

Nanoparticle tracking analysis (NTA)

Particle concentration and size distribution were determined with the NTA instrument LM14C (NanoSight LTD., London, UK) equipped with blue (404 nm, 70 mW) laser and sCMOS camera. Settings for data acquisition were: camera level 14, SOP Standard Measurement, autosettings off, polydispersity medium, reproducibility high, and acquisition time 3x 60 sec. The sample dilution was done to 0.1 μm filtered buffer pre-checked for absence of particles. Each sample was diluted to optimal 40–100 particles/frame concentration for measurement. Data were analyzed with NanoSight NTA 3.0 software with the following settings: auto background subtraction/blur/minimum track length, and detection threshold 5.

Electron microscopy

Negative staining of whole mounted EV samples was performed as described [25]. Briefly, EVs were loaded on 200 mesh grids, fixed with 2% PFA, stained with 2% neutral uranyl acetate, embedded in methyl cellulose uranyl acetate mixture (1.8/0.4%) and viewed with Tecnai 12 (FEI Company, Eindhoven, The Netherland) at 80 kV.

SDS-PAGE and Western blot analysis

Total of 5*1010 particles of all samples were prepared with 6x Laemmli sample buffer with 10% β-mercaptoethanol and run on 4–20% gradient SDS-PAGE (Mini-Protean TGX Precast protein gel, Bio-Rad, Hercules, USA). For Western blot analysis, proteins were transferred to PVDF membrane (Immobilon-P, Merck Millipore, Burlington, USA) at 200 mA for 90 minutes using wet transfer. Nonspecific binding was blocked by with 3% BSA in Tris-buffered saline containing 0.1% Tween-20 (TBST) for 1 hour followed by primary antibody incubation anti-TSG101 (Clone 51/TSG101 BD Biosciences, 1:500), anti-CD41 (clone SZ22, Beckman Coulter, 1:2000), or anti-CD9 (clone C-4, Santa Cruz Biotechnology, Dallas, USA, 1:500) overnight at 4˚C. The membranes were washed three times with TBST followed by incubation with horseradish peroxidase–conjugated anti-mouse secondary antibody in dilution 1:3000 (GE Healthcare Bio-Sciences AB). After washing, the signal was detected using Bio-Rad Clarity Western ECL Substrate (Bio-Rad) and imaged using LAS3000 imaging system (Fuji, Minato, Japan).

Mass spectrometry and data analysis

EV pellets corresponding to 100 μg of total protein were adjusted to 25mM Tris, 75mM NaCl; pH 7.5 and applied to 50 μL of albumin depletion resin slurry (Pierce, Thermo Scientific, Rockform, USA) previously washed with same buffer. Flow through and three washes were collected by centrifugation and deemed to be albumin-depleted EV proteins. The protein concentration was measured by bicinchonic acid assay kit (Thermo Fisher Scientific) for the total protein concentration. Equal amount of protein for each sample was dried in speed vacuum (Savant, Thermo Fisher Scientific), and then dissolved in 6 M urea and 100 mM Tris-HCl (pH 7.4). Reconstitution was performed with 10 mM of dithiothreitol (DTT) for 60 minutes at RT, and thereafter 30mM iodoacetamide for 60 minutes in the dark at RT. Protein digestion was performed with trypsin (18 hour at 37°C) after the consumption of abundant iodoacetamide (30 mM DTT, 60 minutes at RT) and 1:10 dilution with high-purity Milli-Q water (Millipore, Billerica, USA). Finally, the samples were cleaned up with C18 spin columns, and dried in speed vacuum following the dissolution in 0.1% formic acid containing 12.5 fmol Hi3 peptide mixture (Waters Corporation, Beverly, USA) per μl. All procedures were performed according to the manufacturer’s instructions. Liquid chromatography: Four microlitre samples corresponding to 1.4 μg of total protein were injected to the ultra-performance liquid chromatography (UPLC) system (Waters Corporation) (Distler et al, 2014). TRIZAIC nanoTile 85 μm x 100mm HSS-T3u wTRAP was applied as a separating device before mass spectrometry (MS). After loading and trapping, the samples were washed for 2 minutes at 8.0 μL/minute with 1% buffer B. The analytical gradient was used as follows: 0–1 minute 1% B; at 2 minutes 5% B; at 65 minutes 30% B; at 78 minutes 50% B; at 80 minutes 85% B; at 83 minutes 85% B; at 84 minutes 1% B; and at 90 minutes 1% B with 450 nL/minute. Buffer A consists of 0.1% formic acid in water and buffer B of 0.1% formic acid in acetonitrile (Sigma-Aldrich). The data was acquired with UDMSE with Synapt G2-S UDMS (Waters Corporation, Billerica, MA) including ion mobility spectroscopy (IMS). The data range was 100–2000m/z, scan time 1 s, IMS wave velocity 650ms1. Calibration was performed by Glu1- fibrinopeptide B MS2 fragments and Glu1- fibrinopeptide B precursor ion, used during the acquisitions as a lock mass. Progenesis QI for proteomics software (Version 3, Nonlinear Dynamics) was used for processing of raw files. Peptide identification was run with Uniprot human FASTA sequences (UniprotKB Release 2015_09, 20205 sequence entries), and label-free protein quantification performed with Hi-N method (Protein Lynx Global Server) (Silva et al, 2006). The samples were spiked with 12.5 fmol/μL of CLPB_ECOLI (P63285, ClpB protein) peptides (Hi3 E. Coli Standard, Waters). Digesting reagent was trypsin and 2 miss cleavages were allowed. The peptide identification parameters were: fixed modification of cysteine (carbamidomethyl) and variable modification of methionine (oxidation). The peptide error tolerance was set to maximally 10 ppm and the false discovery rate limited to less than 1% and default values (in Progenesis QI for Proteomics) were used for the rest of the parameters. The quantified proteins in all comparisons were compared by ANOVA on a protein-to-protein basis and their expression levels were considered significantly different, if ANOVA p-value was less than 0.05. Principal component analysis (PCA), offering the visualization of the main axes of variation in the data groups, was performed by Progenesis QI for proteomics.

Statistics

Statistical analysis of the flu-SEC experiment was performed by using Prism 8 (GraphPad Software, LLC, USA). One-way ANOVA test was performed without pairing and assuming Gaussian distribution and equal variance followed by Tukey multiple comparisons test with 95% confidence interval. Saphiro-Wilk test was used to test normal distribution, while the Brown–Forsythe test was used for the equality of group variances. Statistical analysis of flow cytometry and proteomics experiments was performed with IBM SPSS version 24 (IBM Corp., Armonk, USA, Released 2016). The data was tested for normality using Saphiro-Wilk test, after which Kruskall-Wallis non-parametric test was used followed by post-hoc Dunn test. Pearson correlation test was used to examine whether there were correlations between proteins analyzed by proteomics. The level of significance was set at p ≤ 0.05 in all experiments.

Data repository

The raw files were converted with MSConvert (ProteoWizard) to mzML-files. The mass spectrometry proteomics data have been deposited to the ProteomeXchange Consortium via the PRIDE (Vizcaino et al 2014) partner repository with the dataset identifier PXD015375.

Results

General characterization of EVs derived from ACD-, citrate- and EDTA-anticoagulated plasma and serum

In this study, we investigated how different anticoagulants and clotting affect the characteristics of blood-derived EVs. To avoid contamination with any residual platelets and/or residual platelets generating artificial EVs, all samples were centrifuged within 30 minutes after blood collection at 2500 × g 15 minutes (twice) as recommended previously [4, 6, 26]. Little or no residual platelets were detected in the samples (S1A Fig). Particle concentrations and size distributions were determined with NTA, and the vesicle morphology in samples was confirmed with TEM. The concentrations of particles calculated per original sample volume of the different plasmas or serum were not statistically different in blood collection set I (p = 0.631), but in set II, some variation was found in EV concentrations between serum and anticoagulated samples (p = 0.001; S1B Fig). Statistical testing for size distribution of EVs was performed for set II which had three technical replicates, but essentially similar data was also obtained from samples of set I with duplicate samples. The analysis revealed statistically significant differences when measured by bins of size classes. The significant increase of particle counts was seen with serum-derived EVs that differed from ACD, citrate and EDTA plasma–derived EVs in size classes 0–100 nm (p = 0.002 (ACD), p = 0.001 (citrate), p = 0.023 (EDTA) and 101–200 nm p = 0.044 (ACD) (S1C Fig). By TEM, all EVs irrespective of plasma or serum source had a similar morphology typically attributed to EVs (S1D Fig). To investigate the protein content of EVs, equal particle numbers based on NTA were loaded into SDS-PAGE gels. The overall protein patterns were similar in the ACD- and citrate-derived EV samples, whereas the protein bands from EDTA- and serum-derived EVs showed visible differences (S1E Fig). In contrast, typical EV-marker proteins as TSG101 and CD9 were detected at comparable levels when analyzed by Western blotting (S1F Fig).

Serum and citrate plasma contain increased numbers of platelet-derived EVs compared to ACD and EDTA plasma samples

In a seminal study of George et al. [7], serum was shown to contain more microparticles i.e. large EVs than ACD plasma. This prompted us to investigate this claim anew with contemporary analytical methods: EV-dedicated flow cytometry (Apogee 50), flu-SEC and Western blotting. EVs of different plasma and serum samples isolated by ultracentrifugation and normalized by particle numbers based on NTA, were analyzed with flow cytometry by anti-CD61 and -CD235a labelling to compare platelet and erythrocyte derived EV proportions in plasma and serum, respectively. There were less CD235a+ EVs compared to CD61+ EVs in all the samples irrespective of the anticoagulant used (Fig 1A). In contrast, more CD61+ events were detected in the serum samples compared to the ACD (p = 0.006) and EDTA (p = 0.001) samples, and although there was a similar trend with the citrate sample, it was not statistically significant. Statistical testing was performed for set II which had three technical replicates, but essentially similar data was also obtained from samples of set I with duplicate samples. Annexin V binding to EVs was analyzed to yield information about phosphatidylserine (PS) expression relevant for procoagulant activity. Staining with (fluorescently-labelled) annexin V was low in all plasma-derived EV samples compared to serum EVs (Fig 1A). Statistical analysis showed significant differences (S2 Table) between serum and ACD, citrate, and EDTA EVs (p = 0.003, p = 0.013, p = 0.006, respectively).

Fig 1. Flow cytometry, fluorescence size exclusion chromatography, and Western blot of extracellular vesicles isolated from ACD-, citrate-, and EDTA-plasma and serum samples.

Fig 1

A) Representative images of the Apogee flow cytometry analysis with anti-CD61-PE, anti-CD235-FITC and annexin V-FITC, respectively, B)Box blots show the average of events/μl (n = 3) for the labelled EVs isolated from plasma and serum samples. For the platelet marker CD61, significant increases in events were detected for serum and citrate-anticoagulated plasma EVs. In contrast, similar concentrations of erythrocyte (CD235a) EVs were present in plasma and serum. Serum EVs bound more a Annexin V per EVs compared to plasma EVs, C) representative chromatograms of plasma- and serum-derived EVs labelled with anti-CD61-PE and characterized with fluorescent size exclusion chromatography (n = 3). EVs were eluted with the void volume of the column at 2.8 min retention time, and the peak at 6.35 min retention time corresponded to the unbound antibody. D) The area under the curve values of the first peak were correlated with the amount of CD61+ EVs in plasma and serum samples. E) probing with anti-CD41 of the Western blots of the plasma and serum -derived EVs to detect platelet-derived EVs (TSG101 and CD9 are shown in S1 Fig). Each lane was loaded with a comparable number of particles based on NTA. Asterisks (*) indicates p < 0.05.

In sample set III, the plasma and serum samples were labelled with anti-CD61 followed by flu-SEC (Fig 1B). Comparison of the chromatograms of the plasma samples with that of the serum sample demonstrated that the concentration of CD61+ EVs was significantly increased in the serum samples compared to ACD, EDTA and citrate plasma (all p<0.001; S3 Table), even up to 40-fold compared to EDTA. While there was no difference in the concentration of CD61+ EVs between the EDTA- and ACD plasma samples, citrate-anticoagulated plasma also had an increased number of CD61+ EVs compared to EDTA (p = 0.046).

When equal particle numbers were loaded on Western blot and probed with anti-CD41 to detect the platelet glycoprotein IIb, the strongest CD41 signal was in the serum-derived EVs, followed by the EVs from citrate plasma, whereas in the ACD- and EDTA-derived EVs the band intensities were equal (Fig 1C). The Western blot, Apogee flow cytometry and Flu-SEC results confirmed a high concentration of platelet-derived EVs in serum and citrate plasma compared to the ACD- and EDTA-plasma samples. Finally, also proteomics confirmed an increase in the presence of CD41 protein in serum and EDTA plasma–derived EV samples compared to ACD and citrate plasma -derived EVs (p = 0.04) in the quantitative proteomics of albumin-depleted samples (Fig 1D).

Protein cargo of the EV corona is modified by anticoagulation or its absence

Intrigued by the observations of the different protein bands in the SDS gel of the isolated EVs (S1E Fig), we performed a quantitative proteomic analysis for both albumin-depleted EVs and non-albumin-depleted EVs isolated from ACD-, citrate-, and EDTA-plasma and serum samples. In total, 225 proteins were detected from the albumin-depleted and 165 from the non-depleted EV samples with mass spectrometry Since all identified and quantified proteins (S4 Table) from the non-albumin depleted samples (n = 91 out of 165) were present in the list of albumin-depleted samples (n = 138 out of 225), we focused on the albumin-depleted proteome. Abundances of the EV proteins were used to perform principal component analysis (PCA). PCA is available in the Progenesis QI for proteomics—software package. It is an unsupervised method to determine relations between the samples and here we directly used the imported mass spectrometry data of the reliable proteins identified with two or more unique peptides. The principal axes of abundance variation are calculated by the software from protein abundances in the samples. When two or more unique peptide -containing proteins with p≤0.05 ANOVA were plotted in PCA, there was a complete separation of the samples into four separate groups according to anticoagulation/coagulation (Fig 2). The Pearson’s correlation coefficiency was calculated for the 138 proteins. A threshold for the p-value was set to 0.05 to define statistical significance. More than 80% of protein pairs were positively or negatively correlated (S5 Table).

Fig 2. Principal component analysis (PCA) of protein quantification data with two or more unique peptide -containing proteins with ANOVA significance p≤0.05.

Fig 2

Green: citrate; blue: ACD; red: EDTA; yellow: serum. Each sample was run in triplicates.

The differences in the EV proteomes from plasma and serum samples were quantitative. A gene ontology analysis was conducted with the FunRich analysis tool [27] using human genome as background. Of the 138 proteins, 107 were mapped for molecular function, cellular component and biological process GO terms. The GO terms with p-value ≤0.05 (Holm-Bonferroni corrected) are shown in Fig 3, and a detailed list of the mapped genes is presented in S6 Table. The most prominent cellular components in GO terms (Fig 3A) were exosomes (GO:0070062), cytoplasm (GO:0005737) and extracellular (GO:0005576) comprising 77.7%, 68.0% and 66.0% of the identified proteins, respectively. The enriched biological process GO terms (Fig 3B) were cell growth and/or maintenance (GO:0016049) and immune response (GO:0006955), comprising 32.4% and 22.5%, respectively. For the molecular function (Fig 3C) enriched GO terms were transporter activity (GO:0005215), structural constituent of cytoskeleton (GO:0005200), structural molecule activity (GO:0005198), and complement activity (GO: 0006956) comprising 14.7%, 14.7%, 11.8%, and 10.8% of the identified proteins, respectively.

Fig 3. Gene ontology enrichment analysis of identified proteins from EVs with two or more unique peptide–containing proteins and p-value ≤0.05 (Holm-Bonferroni corrected) performed with FunRich 2.1.2 software using human genome as a background.

Fig 3

A) Cellular component enrichment analysis, B) molecular function enrichment analysis, and C) biological process enrichment analysis.

Of the 138 proteins, 35 showed significant differences in concentration (ANOVA with Kruskall-Wallis test followed by Dunn´s test), between the plasma and serum EV samples (Table 1). The majority of these proteins [21] were upregulated in the EVs isolated from serum, 12 proteins in the EVs isolated from EDTA-plasma, and two in the EVs isolated from ACD-plasma. The further analysis of 21 proteins with highest mean in serum EVs revealed enriched molecular function in transporter activity (GO:0005215), including apolipoproteins A1, A2 and C3, transferrin and vitamin D binding protein. Additionally, the EVs displayed differences in the amounts of coagulation and complement proteins, protease inhibitors and different classes of immunoglobulins (Table 1). The most prominent GO term in molecular function of combined EDTA and ACD plasma EVs was protein binding (GO:0005515).

Table 1. Proteins (n = 35) showing significant difference between the plasma and serum EV samples (Anova with Kruskall-Wallis test followed by Dunn´s test, p-value ≤ 0.05) are shown.

Five keratins listed here were not excluded although they are considered to originate from exogenous sources such as skin or hair.

Kruskall-Wallis
Group Mean SD ACD Citrate EDTA
p-value p-value p-value
Alpha-1-antitrypsin Citrate 21128.5 3673.3 0.174
EDTA 57249.3 23861.6 0.571 0.054
Serum 84532.5 5897.2 0.141 0.005* 0.365
APOC4-APOC2 readthrough (NMD candidate) Citrate 2899.5 269.1 0.308
EDTA 14746.6 3666.4 0.308 0.042*
Serum 23054.3 322.9 0.042* 0.002* 0.308
Apolipoprotein A-I Citrate 327405.2 26276.5 0.571
EDTA 763780.0 136205.2 0.174 0.054
Serum 964279.7 111475.8 0.031* 0.007* 0.428
Apolipoprotein A-II Citrate 9432.0 1918.8 0.428
EDTA 32012.0 10122.1 0.213 0.042*
Serum 46145.7 3288.2 0.042* 0.005* 0.428
Apolipoprotein C-III Citrate 12313.4 2369.5 0.734
EDTA 45020.7 29899.0 0.089 0.042*
Serum 40119.1 2971.9 0.042* 0.017* 0.734
C4b-binding protein beta chain Citrate 32830.5 4683.5 0.308
EDTA 145233.1 92104.5 0.174 0.017*
Serum 129147.1 21501.1 0.089 0.007* 0.734
Clusterin Citrate 15921.9 2556.5 0.174
EDTA 64159.9 2776.6 0.113 0.003*
Serum 26015. 4840.8 1.00 0.174 0.113
Complement C1s subcomponent Citrate 130601.2 18724.9 0.308
EDTA 77030.6 18048.8 0.042* 0.308
Serum 574764.3 80460.7 0.308 0.042* 0.002*
Complement factor H Citrate 37145.7 4413.8 0.571
EDTA 97696.5 24032.5 0.213 0.07
Serum 161619.3 19798.8 0.024* 0.005* 0.308
Extracellular matrix protein 1 Citrate 1361.0 349.4 0.910
EDTA 2848.3 764.6 0.113 0.141
Serum 7871.9 5854.9 0.009* 0.013* 0.3008
Far upstream element-binding protein 2 Citrate 40731.4 11563.2 0.428
EDTA 130437.5 10503.6 0.428 0.113
Serum 272062.8 40803.3 0.042* 0.005* 0.213
Fibrinogen alpha chain Citrate 286470.0 80015.7 0.497
EDTA 1040565.0 140516.8 0.213 0.054
Serum 178365.8 33284.6 0.089 0.308 0.003*
Fibrinogen beta chain Citrate 247084.9 82918.2 0.571
EDTA 796061.9 71036.9 0.213 0.07
Serum 52282.2 24865.0 0.07 0.213 0.002*
Fibrinogen gamma chain Citrate 214132.6 59581.7 0.428
EDTA 681749.2 115693.1 0.428 0.113
Serum 112276.9 6000.7 0.042* 0.213 0.005*
Ficolin-3 Citrate 39691.6 6389.57 0.571
EDTA 3262480.8 16914469 0.024* 0.005*
Serum 175056.8 89930.4 0.213 0.07 0.308
Haptoglobin-related protein Citrate 72310.9 6719.7 0.005*
EDTA 216281.3 208441.5 0.308 0.07
Serum 121909.9 24163.3 0.174 0.141 0.734
Immunoglobulin heavy variable 5–51 Citrate 2005.0 146.1 0.089
EDTA 27441.8 12458.0 0.174 0.002*
Serum 3673.2 79.9 0.734 0.174 0.089
Immunoglobulin kappa variable 3–20 Citrate 23823.5 1779.9 0.571
EDTA 79664.0 33562.0 0.024* 0.005*
Serum 46655.7 3347.3 0.213 0.07 0.308
Immunoglobulin lambda constant 2 Citrate 34925.7 9817.4 0.365
EDTA 90591.5 19342.8 0.365 0.07
Serum 145174.1 28041.9 0.042* 0.003* 0.258
Immunoglobulin lambda constant 7 Citrate 3043.6 1419.7 0.428
EDTA 1933.9 501.0 0.213 0.651
Serum 438.4 349.6 0.007* 0.054 0.141
Immunoglobulin lambda variable 2–14 Citrate 11752.6 3612.3 0.910
EDTA 21819.8 4915.8 0.054 0.07
Serum 23822.8 8356.2 0.024* 0.031* 0.734
Immunoglobulin lambda-like polypeptide 5 Citrate 67358.0 15634.6 0.428
EDTA 186777.2 68310.8 0.113 0.017*
Serum 164633.0 4839.5 0.089 0.013* 0.91
Inter-alpha-trypsin inhibitor heavy chain H4 Citrate 2136.6 130.5 0.910
EDTA 4742.3 2796.6 0.141 0.113
Serum 27310.24 1537.1 0.013* 0.009* 0.308
Keratin type II cuticular Hb6 Citrate 4676.76 1131.9 0.571
EDTA 226331.9 72476.3 0.005* 0.024*
Serum 9422.9 332.7 0.07 0.231 0.308
Keratin type II cytoskeletal 1b Citrate 6686.7 1671.8 0.571
EDTA 23137.7 6736.6 0.089 0.024*
Serum 25899.7 3549.7 0.07 0.017* 0.91
Keratin type II cytoskeletal 3 Citrate 8968.3 1474.3 1.00
EDTA 16936.0 5221.0 0.571 0.089
Serum 25805.0 3225.4 0.089 0.005* 0.258
Keratin type II cytoskeletal 7 Citrate 9786.3 5026.1 0.428
EDTA 28739.1 9806.1 0.428 0.113
Serum 78335.4 27832.8 0.042* 0.005* 0.213
Keratin type II cytoskeletal 75 Citrate 17435.1 3417.5 0.910
EDTA 23954.2 5558.9 0.231 0.258
Serum 39640.8 7021.8 0.013* 0.017* 0.213
Mannan-binding lectin serine protease 1 Citrate 19359.2 838.0 1.00
EDTA 369877.9 451573.1 0.089 0.005*
Serum 82930.6 47213.7 0.308 0.031* 0.497
NFX1-type zinc finger-containing protein 1 Citrate 1665.6 406.6 0.258
EDTA 5768.4 2119.3 0.365 0.042*
Serum 9485.0 2649.1 0.07 0.003* 0.365
Pro-thrombin Citrate 16532.6 2078.7 0.174
EDTA 36920.9 16154.9 1.00 0.174
Serum 92027.3 11207.8 0.113 0.003* 0.113
Putative uncharacterized protein MYH16 Citrate 393.4 93.2 0.734
EDTA 5638.6 2475.0 0.024* 0.009*
Serum 734.2 125.3 0.308 0.174 0.213
Serotransferrin Citrate 246039.8 45043.8 0.428
EDTA 603798.7 62743.3 0.258 0.054
Serum 1127260.8 200381.7 0.031* 0.003* 0.308*
Transthyretin Citrate 850.2 268.5 0.024*
EDTA 5663.8 5519.4 1.00 0.024*
Serum 1237.8 259.7 0.113 0.497 0.113
Vitamin D-binding protein Citrate 11973.0 1888.2 0.497
EDTA 43094.2 16511.6 0.258 0.07
Serum 79524.5 15148.7 0.042* 0.007* 0.365

The proteome of plasma EVs has been reported in several studies and can be obtained from Exocarta [28] and EVpedia [29]. To understand our results, we performed data comparisons between our results and the results from two other studies which we deemed most relevant by their study design. The study of Kalra et al. compared the proteome of plasma EVs which had been isolated with three different isolation methods: differential ultracentrifugation (dUC), immunoaffinity, and discontinuous gradient ultracentrifugation (DG) [30]. This study reported 56 common proteins with our proteome from dUC and DG samples, including complement proteins, immunoglobulins, apolipoproteins and keratins. Similar results have also been reported in studies using dUC [3134] or SEC as isolation method [3537]. In the study of Karimi et al. it was shown that by combining dUC, DG and SEC, it is possible to avoid lipoprotein and soluble protein contamination and to isolate highly purified plasma EVs for proteomic analysis [36]. Comparing our 138 proteins from UC-isolated EVs with those of dUC-isolated EVs [30] and dUC combined with DG and followed by SEC isolated EVs [36] showed that 46 proteins were shared with both of the other data sets, 9 proteins only with Kalra et al. and 53 proteins only with Karimi et al. (Fig 4).

Fig 4. Venn diagram of overlapping proteins from a comparison of the proteomic data of our study and two previous studies of proteome of EVs [30, 36].

Fig 4

Because we found similarities in the EV proteome of our study with these two previous studies, which had used different and more diligent EV isolation procedures, we hypothesized that there may be a shared “EV protein corona”. To investigate this hypothesis, we compared our EV proteome to that of NPs, which had been incubated with plasma to generate a protein corona. We compared the list of the 108 proteins which were shared with our study and two previous EV studies, assuming that these proteins belonged to the EV protein corona, to a set of 84 proteins which were shared between two previous NP proteomic studies [22, 38]. Kari et al. used multi-parametric surface plasmon resonance to identify hard and soft protein corona of liposomes in situ [38], and Weber et al. analyzed the polystyrene NP protein corona after isolation by dUC and asymmetric flow field-flow fractionation [22]. In total, 89 of the “EV corona proteins” were identical to those reported to belong to the NP corona proteins (65%; Fig 5). A gene ontology analysis with the FunRich analysis tool [27] using human genome as background enabled us to map 73 proteins (out of the 89 common proteins) for molecular function, cellular component and biological process GO terms (S6 Table). The most prominent cellular component GO terms were exosomes (GO:0070062), extracellular (GO:0005576) and cytoplasm (GO: 0005737) comprising 86%, 75% and 63% of the identified proteins, respectively. The enriched biological process GO terms were cell growth and/or maintenance (GO:0016049), immune response (GO:0006955) and transport (GO: 0006810) comprising 32%, 30% and 20%, respectively. For the molecular function enriched GO terms were transporter activity (GO:0005215), structural constituent of cytoskeleton (GO:0005200) and complement activity (GO: 0006956), comprising 20%, 17% and 14% of the identified proteins, respectively.

Fig 5. Venn diagram comparing the proteomic data of our study to a shared proteome from two previous studies of nanoparticle corona proteins accumulated from plasma [22, 38] showing a set of overlapping proteins, which suggests that a common corona proteome of plasma proteins accumulates on EVs and synthetic particles [22, 38].

Fig 5

Discussion

At present, blood-derived EVs are a potential source for new biomarkers. Since a blood sample is an ex vivo sample, the impact of the pre-analytical choices prior to EV isolation needs to be accounted for to make intelligent use of high-throughput data utilizing samples of large cohorts and biobanks. Therefore, we compared EVs isolated from ACD-, citrate and EDTA-plasma, and serum, to investigate the effects of anticoagulation on the cellular origin and protein composition of the isolated EVs. An early study by George et al. compared large EVs from plasma and serum, and they showed that serum contained more platelet-derived microparticles than ACD plasma [7]. Because their study disregarded a large bulk of EVs, we readdressed this issue with contemporary analytical EV methodologies. We showed with four different methods that the serum samples indeed contain a significantly higher concentration of platelet-derived EVs than the plasma samples, and that the serum-derived EVs bound more Annexin V. The number of platelet-derived EVs was also increased in citrate plasma compared to ACD and EDTA, which confirms previous results [39]. This suggests that citrate inhibits platelet activation less efficiently than ACD and EDTA, which results in generation platelet-derived EVs in blood samples during and after blood collection, especially if there is a delay between the sample collection and processing. This is significant, because uncontrolled release of platelet-derived EVs affects biomarker discovery, e.g., platelet-derived EVs were shown to skew the miRNA populations in patient and control samples [40]. Although the total concentration and size distribution of the plasma-derived EVs were essentially similar between the various anticoagulated plasma and serum samples, a slight difference in the particle numbers was observed between sample sets I and II, where in set II, the concentration of serum-derived EVs was higher than in plasma. This difference may be explained by the variation between the donor pools, and one of the limitations of this study was that the EV analyses could not be associated to the individual donor characteristics such as age or gender So far, very few studies have addressed how such factors impact the EV concentrations in healthy populations [4143]. However, the use of large, well-prepared sample pools enabled us to apply the same material systematically in multiple analyses, strengthening the comparison of the results between analytics.

Ultracentrifugation is still the most used method for EV isolation from plasma (>60%) or serum (>55%) reported in EV-TRACK (http://evtrack.org/, accessed 20.01.2020), although other methods e.g. SEC and density gradient ultracentrifugation have been adopted. Thus, to mimic the situation with most studies, the isolation of EVs in this study was performed with dUC with one washing step, except Flu-SEC. The use of dUC is another limitation of this study, because dUC is known to co-isolate protein aggregates and lipoproteins [44, 45]. Additionally, the recovery of EVs with dUC is variable (10–80%) and often low [46] and it excludes the smallest of EVs and exomeres, to which little attention has been focused so far [47, 48]. Thus, this study did not address the possible alterations in the smallest EV subpopulations.

Several studies of proteomics on plasma and/or serum-derived EVs using various isolation methods have been published [32, 3437], and regardless of the isolation method, the published EV proteomes show a remarkable similarity. This indicates that certain plasma proteins are tightly bound to the EV surface constituting a true protein corona rather than being mere co-isolating contaminants. The proteome of EVs comprised lipoproteins, immunoglobulins, and coagulation and complement proteins. The presence of several transporter proteins in the protein corona suggests that EV surfaces may have a previously unconsidered role in biomolecule transportation. As the enzymatic removal of the EV surface proteins has been shown to hamper cellular uptake [49, 50], the protein corona may affect the functional properties of EVs. The heterogeneity of the protein corona was shown to affect the hydrodynamic range of EVs, as well as their mobility in solution and extracellular matrix [51].

Our proteomics analysis of the albumin-depleted EVs from plasma and serum showed an overlap not only with the previous EV studies [30, 36], but also with NP studies [22, 38]. The NP studies chosen for comparison applied isolation methods asymmetric field flow fractionation and multi-parametric surface plasmon resonance which are considered not to co-isolate soluble proteins, and thereby strengthen the concept that the shared proteins with EVs are unlikely to be co-isolated—artefacts. Of note, in some corona studies NPs added to plasma were isolated by methods which are also used to isolate EVs from plasma and serum [5256]. In such studies, one cannot conclude whether the reported protein corona of NPs originates truly from NPs, from co-isolated EVs, or both. In future studies, this aspect should be taken into account when conducting NP protein corona research, as also noted by a recent viewpoint article [57].

The similarities between the shared extravesicular cargo of EVs and NPs imply that both EVs and NPs accumulate a selected plasma protein corona on their surface, which may be applicable to biomarker discovery. Many of the surface-attached proteins of EVs associate with pathological states and thus could be useful for diagnostics. For example, synovial fluid-derived EVs of rheumatic arthritis patients were shown to carry complement factors and complement activator molecules [58], and the adhered protein composition of EVs was shown to reflect the disease state in preeclampsia [59].

To our knowledge, this is the first study highlighting the importance of the EV corona. To conclude, we state that plasma obtained with different anticoagulant and/or serum should not be mixed as a source of EVs for biomarker discovery. This is particularly relevant for clinical studies and biobank samples. Secondly, an enrichment of platelet-derived EVs from serum samples may offer new opportunities to study platelet-associated pathologies. Thirdly, the comparison of proteomic studies suggests that EVs have a protein corona that includes both soft and hard coronas offering an interactive surface with biological membranes, which may offer novel insights in the pathophysiological roles of EVs. Since the investigations on the communicasome role of EVs have so far predominantly concentrated on the intravesicular cargo and regarded the corona proteins simply as contaminants, we suggest that this “piggyback” cargo should be re-evaluated. We expect our study to pave a way for more discoveries regarding the role of the extracellular cargo of EVs.

Supporting information

S1 Raw images

(PDF)

S1 Fig. General characterization of plasma and serum–derived EVs.

(JPG)

S1 Table. Workflow of the study.

(DOCX)

S2 Table. Flow cytometry analysis of plasma and serum–derived EVs.

(DOCX)

S3 Table. Flu-SEC analysis of plasma and serum–derived EVs.

(DOCX)

S4 Table. Identified and quantified proteins.

(XLSX)

S5 Table. Pearson correlation matrix of identified and quantified proteins.

(XLSX)

S6 Table. A gene ontology analysis of “EV corona proteins”.

(DOCX)

S7 Table. A gene ontology analysis of “NP and EV corona proteins”.

(DOCX)

Acknowledgments

We thank all the volunteers for participating in this study.

Data Availability

All proteomic data files are available from the PRIDE database (accession number PXD015375).

Funding Statement

This study has been supported by the Academy of Finland (grants 287089 (PRMS) and 315227(M. Palviainen)), Magnus Ehrnrooth Foundation (PRMS), Medicinska Understödsföreningen Liv och Hälsa rf. (PRMS) and by the National Research, Development and Innovation Office NKFIH, Hungary (ZV, grants PD 121326 and NVKP_16-1-2016-0007). ZV was supported by the János Bolyai Research Fellowship. DK was supported by the ÚNKP-19-3 New National Excellence Program of the Ministry for Innovation and Technology.

References

  • 1.Fendl B, Weiss R, Fischer MB, Spittler A, Weber V. Characterization of extracellular vesicles in whole blood: influence of pre-analytical parameters and visualization of vesicle-cell interactions using imaging flow cytometry. Biochem Biophys Res Commun 2016;478(1):168–173. 10.1016/j.bbrc.2016.07.073 [DOI] [PubMed] [Google Scholar]
  • 2.Xu R, Rai A, Chen M, Suwakulsiri W, Greening DW, Simpson RJ. Extracellular vesicles in cancer—implications for future improvements in cancer care. Nature Reviews Clinical Oncology 2018;15(10):617 10.1038/s41571-018-0036-9 [DOI] [PubMed] [Google Scholar]
  • 3.Zamani P, Fereydouni N, Butler AE, Navashenaq JG, Sahebkar A. The therapeutic and diagnostic role of exosomes in cardiovascular diseases. Trends Cardiovasc Med 2019;29(6):313–323. 10.1016/j.tcm.2018.10.010 [DOI] [PubMed] [Google Scholar]
  • 4.Lacroix R, Judicone C, Poncelet P, Robert S, Arnaud L, Sampol J, et al. Impact of pre‐analytical parameters on the measurement of circulating microparticles: towards standardization of protocol. Journal of Thrombosis and Haemostasis 2012;10(3):437–446. 10.1111/j.1538-7836.2011.04610.x [DOI] [PubMed] [Google Scholar]
  • 5.György B, Pálóczi K, Kovács A, Barabás E, Bekő G, Várnai K, et al. Improved circulating microparticle analysis in acid-citrate dextrose (ACD) anticoagulant tube. Thromb Res 2014;133(2):285–292. 10.1016/j.thromres.2013.11.010 [DOI] [PubMed] [Google Scholar]
  • 6.Clayton A, Boilard E, Buzas EI, Cheng L, Falcón-Perez JM, Gardiner C, et al. Considerations towards a roadmap for collection, handling and storage of blood extracellular vesicles. Journal of Extracellular Vesicles 2019;8(1):1647027 10.1080/20013078.2019.1647027 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.George JN, Thoi LL, McManus LM, Reimann TA. Isolation of human platelet membrane microparticles from plasma and serum. Blood 1982;60(4):834–840. [PubMed] [Google Scholar]
  • 8.Magnette A, Chatelain M, Chatelain B, Ten Cate H, Mullier F. Pre-analytical issues in the haemostasis laboratory: guidance for the clinical laboratories. Thrombosis journal 2016;14(1):49. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Maiolo D, Del Pino P, Metrangolo P, Parak WJ, Baldelli Bombelli F. Nanomedicine delivery: does protein corona route to the target or off road? Nanomedicine 2015;10(21):3231–3247. 10.2217/nnm.15.163 [DOI] [PubMed] [Google Scholar]
  • 10.Van Hong Nguyen Beom-Jin Lee. Protein corona: a new approach for nanomedicine design. International journal of nanomedicine 2017;12:3137 10.2147/IJN.S129300 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Caracciolo G, Farokhzad OC, Mahmoudi M. Biological identity of nanoparticles in vivo: clinical implications of the protein corona. Trends Biotechnol 2017;35(3):257–264. 10.1016/j.tibtech.2016.08.011 [DOI] [PubMed] [Google Scholar]
  • 12.Zheng T, Pierre-Pierre N, Yan X, Huo Q, Almodovar AJ, Valerio F, et al. Gold nanoparticle-enabled blood test for early stage cancer detection and risk assessment. ACS applied materials & interfaces 2015;7(12):6819–6827. [DOI] [PubMed] [Google Scholar]
  • 13.Papi M, Palmieri V, Digiacomo L, Giulimondi F, Palchetti S, Ciasca G, et al. Converting the personalized biomolecular corona of graphene oxide nanoflakes into a high-throughput diagnostic test for early cancer detection. Nanoscale 2019;11(32):15339–15346. 10.1039/c9nr01413f [DOI] [PubMed] [Google Scholar]
  • 14.Di Domenico M, Pozzi D, Palchetti S, Digiacomo L, Iorio R, Astarita C, et al. Nanoparticle‐biomolecular corona: A new approach for the early detection of non‐small‐cell lung cancer. J Cell Physiol 2019;234(6):9378–9386. 10.1002/jcp.27622 [DOI] [PubMed] [Google Scholar]
  • 15.Blundell EL, Healey MJ, Holton E, Sivakumaran M, Manstana S, Platt M. Characterisation of the protein corona using tunable resistive pulse sensing: determining the change and distribution of a particle’s surface charge. Analytical and bioanalytical chemistry 2016;408(21):5757–5768. 10.1007/s00216-016-9678-6 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Walkey CD, Olsen JB, Guo H, Emili A, Chan WC. Nanoparticle size and surface chemistry determine serum protein adsorption and macrophage uptake. J Am Chem Soc 2012;134(4):2139–2147. 10.1021/ja2084338 [DOI] [PubMed] [Google Scholar]
  • 17.Milani S, Baldelli Bombelli F, Pitek AS, Dawson KA, Radler J. Reversible versus irreversible binding of transferrin to polystyrene nanoparticles: soft and hard corona. ACS nano 2012;6(3):2532–2541. 10.1021/nn204951s [DOI] [PubMed] [Google Scholar]
  • 18.Ahsan SM, Rao CM, Ahmad MF. Nanoparticle-protein interaction: the significance and role of protein corona Cellular and Molecular Toxicology of Nanoparticles: Springer; 2018. p. 175–198. [DOI] [PubMed] [Google Scholar]
  • 19.Dobrovolskaia MA, Patri AK, Zheng J, Clogston JD, Ayub N, Aggarwal P, et al. Interaction of colloidal gold nanoparticles with human blood: effects on particle size and analysis of plasma protein binding profiles. Nanomedicine: Nanotechnology, Biology and Medicine 2009;5(2):106–117. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Palchetti S, Colapicchioni V, Digiacomo L, Caracciolo G, Pozzi D, Capriotti AL, et al. The protein corona of circulating PEGylated liposomes. Biochimica et Biophysica Acta (BBA)-Biomembranes 2016;1858(2):189–196. [DOI] [PubMed] [Google Scholar]
  • 21.del Pilar Chantada-Vázquez M, López AC, Bravo SB, Vázquez-Estévez S, Acea-Nebril B, Núñez C. Proteomic analysis of the bio-corona formed on the surface of (Au, Ag, Pt)-nanoparticles in human serum. Colloids and Surfaces B: Biointerfaces 2019;177:141–148. 10.1016/j.colsurfb.2019.01.056 [DOI] [PubMed] [Google Scholar]
  • 22.Weber C, Simon J, Mailänder V, Morsbach S, Landfester K. Preservation of the soft protein corona in distinct flow allows identification of weakly bound proteins. Acta biomaterialia 2018;76:217–224. 10.1016/j.actbio.2018.05.057 [DOI] [PubMed] [Google Scholar]
  • 23.Van Deun J, Mestdagh P, Agostinis P, Akay Ö, Anand S, Anckaert J, et al. EV-TRACK: transparent reporting and centralizing knowledge in extracellular vesicle research. Nature methods 2017;14(3):228 10.1038/nmeth.4185 [DOI] [PubMed] [Google Scholar]
  • 24.Kitka D, Mihály J, Fraikin J, Beke-Somfai T, Varga Z. Detection and phenotyping of extracellular vesicles by size exclusion chromatography coupled with on-line fluorescence detection. Scientific Reports 2019;9(1):1–7. 10.1038/s41598-018-37186-2 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Puhka M, Nordberg ME, Valkonen S, Rannikko A, Kallioniemi O, Siljander P, et al. KeepEX, a simple dilution protocol for improving extracellular vesicle yields from urine. European Journal of Pharmaceutical Sciences 2017;98:30–39. 10.1016/j.ejps.2016.10.021 [DOI] [PubMed] [Google Scholar]
  • 26.Witwer KW, Buzas EI, Bemis LT, Bora A, Lässer C, Lötvall J, et al. Standardization of sample collection, isolation and analysis methods in extracellular vesicle research. Journal of extracellular vesicles 2013;2(1):20360. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Pathan M, Keerthikumar S, Chisanga D, Alessandro R, Ang C, Askenase P, et al. A novel community driven software for functional enrichment analysis of extracellular vesicles data. Journal of Extracellular Vesicles 2017;6(1):1321455 10.1080/20013078.2017.1321455 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Keerthikumar S, Chisanga D, Ariyaratne D, Al Saffar H, Anand S, Zhao K, et al. ExoCarta: a web-based compendium of exosomal cargo. J Mol Biol 2016;428(4):688–692. 10.1016/j.jmb.2015.09.019 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29.Kim D, Lee J, Kim SR, Choi D, Yoon YJ, Kim JH, et al. EVpedia: a community web portal for extracellular vesicles research. Bioinformatics 2015;31(6):933–939. 10.1093/bioinformatics/btu741 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Kalra H, Adda CG, Liem M, Ang C, Mechler A, Simpson RJ, et al. Comparative proteomics evaluation of plasma exosome isolation techniques and assessment of the stability of exosomes in normal human blood plasma. Proteomics 2013;13(22):3354–3364. 10.1002/pmic.201300282 [DOI] [PubMed] [Google Scholar]
  • 31.Bastos-Amador P, Royo F, Gonzalez E, Conde-Vancells J, Palomo-Diez L, Borras FE, et al. Proteomic analysis of microvesicles from plasma of healthy donors reveals high individual variability. Journal of proteomics 2012;75(12):3574–3584. 10.1016/j.jprot.2012.03.054 [DOI] [PubMed] [Google Scholar]
  • 32.Cheow ESH, Cheng WC, Lee CN, De Kleijn D, Sorokin V, Sze SK. Plasma-derived extracellular vesicles contain predictive biomarkers and potential therapeutic targets for myocardial ischemic (MI) injury. Molecular & Cellular Proteomics 2016;15(8):2628–2640. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Shtam T, Naryzhny S, Kopylov A, Petrenko E, Samsonov R, Kamyshinsky R, et al. Functional properties of circulating exosomes mediated by surface-attached plasma proteins. Journal of Hematology 2018;7(4):149–153. 10.14740/jh412w [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34.Shtam T, Naryzhny S, Samsonov R, Karasik D, Mizgirev I, Kopylov A, et al. Plasma exosomes stimulate breast cancer metastasis through surface interactions and activation of FAK signaling. Breast Cancer Res Treat 2019;174(1):129–141. 10.1007/s10549-018-5043-0 [DOI] [PubMed] [Google Scholar]
  • 35.de Menezes-Neto A, Sáez MJF, Lozano-Ramos I, Segui-Barber J, Martin-Jaular L, Ullate JME, et al. Size-exclusion chromatography as a stand-alone methodology identifies novel markers in mass spectrometry analyses of plasma-derived vesicles from healthy individuals. Journal of extracellular vesicles 2015;4(1):27378. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.Karimi N, Cvjetkovic A, Jang SC, Crescitelli R, Feizi MAH, Nieuwland R, et al. Detailed analysis of the plasma extracellular vesicle proteome after separation from lipoproteins. Cellular and molecular life sciences 2018;75(15):2873–2886. 10.1007/s00018-018-2773-4 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Smolarz M, Pietrowska M, Matysiak N, Mielańczyk Ł, Widłak P. Proteome Profiling of Exosomes Purified from a Small Amount of Human Serum: The Problem of Co-Purified Serum Components. Proteomes 2019;7(2):18. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38.Kari OK, Ndika J, Parkkila P, Louna A, Lajunen T, Puustinen A, et al. In situ analysis of liposome hard and soft protein corona structure and composition in a single label-free workflow. Nanoscale 2020. [DOI] [PubMed] [Google Scholar]
  • 39.György B, Pálóczi K, Kovács A, Barabás E, Bekő G, Várnai K, et al. Improved circulating microparticle analysis in acid-citrate dextrose (ACD) anticoagulant tube. Thromb Res 2014;133(2):285–292. 10.1016/j.thromres.2013.11.010 [DOI] [PubMed] [Google Scholar]
  • 40.Mitchell AJ, Gray WD, Hayek SS, Ko Y, Thomas S, Rooney K, et al. Platelets confound the measurement of extracellular miRNA in archived plasma. Scientific reports 2016;6:32651 10.1038/srep32651 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 41.Frühbeis C, Helmig S, Tug S, Simon P, Krämer-Albers E. Physical exercise induces rapid release of small extracellular vesicles into the circulation. Journal of extracellular vesicles 2015;4(1):28239. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 42.Arraud N, Linares R, Tan S, Gounou C, Pasquet J, Mornet S, et al. Extracellular vesicles from blood plasma: determination of their morphology, size, phenotype and concentration. Journal of Thrombosis and Haemostasis 2014;12(5):614–627. 10.1111/jth.12554 [DOI] [PubMed] [Google Scholar]
  • 43.Eitan E, Green J, Bodogai M, Mode NA, Bæk R, Jørgensen MM, et al. Age-related changes in plasma extracellular vesicle characteristics and internalization by leukocytes. Scientific reports 2017;7(1):1–14. 10.1038/s41598-016-0028-x [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 44.Lane RE, Korbie D, Trau M, Hill MM. Purification protocols for extracellular vesicles Extracellular Vesicles: Springer; 2017. p. 111–130. [DOI] [PubMed] [Google Scholar]
  • 45.Cvjetkovic A, Lötvall J, Lässer C. The influence of rotor type and centrifugation time on the yield and purity of extracellular vesicles. Journal of extracellular vesicles 2014;3(1):23111. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46.Coumans FAW, Brisson AR, Buzas EI, Dignat-George F, Drees EEE, El-Andaloussi S, et al. Methodological Guidelines to Study Extracellular Vesicles. Circ Res 2017. May 12;120(10):1632–1648. 10.1161/CIRCRESAHA.117.309417 [DOI] [PubMed] [Google Scholar]
  • 47.Multia E, Tear CJY, Palviainen M, Siljander P, Riekkola M. Fast isolation of highly specific population of platelet-derived extracellular vesicles from blood plasma by affinity monolithic column, immobilized with anti-human CD61 antibody. Anal Chim Acta 2019;1091:160–168. 10.1016/j.aca.2019.09.022 [DOI] [PubMed] [Google Scholar]
  • 48.Zhang H, Freitas D, Kim HS, Fabijanic K, Li Z, Chen H, et al. Identification of distinct nanoparticles and subsets of extracellular vesicles by asymmetric flow field-flow fractionation. Nat Cell Biol 2018;20(3):332–343. 10.1038/s41556-018-0040-4 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 49.Smyth TJ, Redzic JS, Graner MW, Anchordoquy TJ. Examination of the specificity of tumor cell derived exosomes with tumor cells in vitro. Biochimica et Biophysica Acta (BBA)-Biomembranes 2014;1838(11):2954–2965. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 50.Escrevente C, Keller S, Altevogt P, Costa J. Interaction and uptake of exosomes by ovarian cancer cells. BMC Cancer 2011;11(1):108. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 51.Skliar M, Chernyshev VS, Belnap DM, Sergey GV, Al-Hakami SM, Bernard PS, et al. Membrane proteins significantly restrict exosome mobility. Biochem Biophys Res Commun 2018;501(4):1055–1059. 10.1016/j.bbrc.2018.05.107 [DOI] [PubMed] [Google Scholar]
  • 52.Chen F, Wang G, Griffin JI, Brenneman B, Banda NK, Holers VM, et al. Complement proteins bind to nanoparticle protein corona and undergo dynamic exchange in vivo. Nature nanotechnology 2017;12(4):387 10.1038/nnano.2016.269 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 53.Lundqvist M, Augustsson C, Lilja M, Lundkvist K, Dahlbäck B, Linse S, et al. The nanoparticle protein corona formed in human blood or human blood fractions. PloS one 2017;12(4):e0175871 10.1371/journal.pone.0175871 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 54.Kokkinopoulou M, Simon J, Landfester K, Mailänder V, Lieberwirth I. Visualization of the protein corona: towards a biomolecular understanding of nanoparticle-cell-interactions. Nanoscale 2017;9(25):8858–8870. 10.1039/c7nr02977b [DOI] [PubMed] [Google Scholar]
  • 55.Partikel K, Korte R, Mulac D, Humpf H, Langer K. Serum type and concentration both affect the protein-corona composition of PLGA nanoparticles. Beilstein journal of nanotechnology 2019;10(1):1002–1015. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 56.Gorshkov V, Bubis JA, Solovyeva EM, Gorshkov MV, Kjeldsen F. Protein corona formed on silver nanoparticles in blood plasma is highly selective and resistant to physicochemical changes of the solution. Environmental Science: Nano 2019;6(4):1089–1098. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 57.Simonsen JB, Münter R. Pay attention to the biological nanoparticles when studying the protein corona on nanomedicines. Angewandte Chemie International Edition 2020. [DOI] [PubMed] [Google Scholar]
  • 58.Biró É, Nieuwland R, Tak PP, Pronk LM, Schaap MC, Sturk A, et al. Activated complement components and complement activator molecules on the surface of cell-derived microparticles in patients with rheumatoid arthritis and healthy individuals. Ann Rheum Dis 2007;66(8):1085–1092. 10.1136/ard.2006.061309 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 59.Tan KH, Tan SS, Sze SK, Lee WKR, Ng MJ, Lim SK. Plasma biomarker discovery in preeclampsia using a novel differential isolation technology for circulating extracellular vesicles. Obstet Gynecol 2014;211(4):380. e1–380. e13. [DOI] [PubMed] [Google Scholar]

Decision Letter 0

John Matthew Koomen

29 Apr 2020

PONE-D-20-08075

Extracellular vesicles from human plasma and serum are carriers of extravesicular cargo ─ implications for biomarker discovery

PLOS ONE

Dear Dr Siljander,

Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process.

The reviewers were both very favorable in their reviews, but noted some changes that need to be made to the manuscript.  Because this journal focuses on transparency of methods and clarity of presentation, please carefully address the comments requesting explanation of the statistical approaches.  Also, please check on the figure quality to make sure that they will have sufficient resolution for publication.

We would appreciate receiving your revised manuscript by Jun 13 2020 11:59PM. When you are ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.

If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter.

To enhance the reproducibility of your results, we recommend that if applicable you deposit your laboratory protocols in protocols.io, where a protocol can be assigned its own identifier (DOI) such that it can be cited independently in the future. For instructions see: http://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols

Please include the following items when submitting your revised manuscript:

  • A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). This letter should be uploaded as separate file and labeled 'Response to Reviewers'.

  • A marked-up copy of your manuscript that highlights changes made to the original version. This file should be uploaded as separate file and labeled 'Revised Manuscript with Track Changes'.

  • An unmarked version of your revised paper without tracked changes. This file should be uploaded as separate file and labeled 'Manuscript'.

Please note while forming your response, if your article is accepted, you may have the opportunity to make the peer review history publicly available. The record will include editor decision letters (with reviews) and your responses to reviewer comments. If eligible, we will contact you to opt in or out.

We look forward to receiving your revised manuscript.

Kind regards,

John Matthew Koomen, PhD

Academic Editor

PLOS ONE

Journal Requirements:

When submitting your revision, we need you to address these additional requirements.

1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf

2. PLOS ONE now requires that authors provide the original uncropped and unadjusted images underlying all blot or gel results reported in a submission’s figures or Supporting Information files. This policy and the journal’s other requirements for blot/gel reporting and figure preparation are described in detail at https://journals.plos.org/plosone/s/figures#loc-blot-and-gel-reporting-requirements and https://journals.plos.org/plosone/s/figures#loc-preparing-figures-from-image-files. When you submit your revised manuscript, please ensure that your figures adhere fully to these guidelines and provide the original underlying images for all blot or gel data reported in your submission. See the following link for instructions on providing the original image data: https://journals.plos.org/plosone/s/figures#loc-original-images-for-blots-and-gels.

In your cover letter, please note whether your blot/gel image data are in Supporting Information or posted at a public data repository, provide the repository URL if relevant, and provide specific details as to which raw blot/gel images, if any, are not available. Email us at plosone@plos.org if you have any questions.

3. We note that you have included the phrase “data not shown” in your manuscript. Unfortunately, this does not meet our data sharing requirements. PLOS does not permit references to inaccessible data. We require that authors provide all relevant data within the paper, Supporting Information files, or in an acceptable, public repository. Please add a citation to support this phrase or upload the data that corresponds with these findings to a stable repository (such as Figshare or Dryad) and provide and URLs, DOIs, or accession numbers that may be used to access these data. Or, if the data are not a core part of the research being presented in your study, we ask that you remove the phrase that refers to these data.

4. Thank you for including your ethic statement in the methods section:

"Blood samples were obtained from healthy, fasting volunteers and collected into ACD-A (Vacuette #455055, Greiner Bio-One, Kremsmünster, Austria), citrate (Vacuette #455322, Greiner Bio-One), serum (BD #369032, BD Biosciences, Franklin Lakes, USA) and EDTA (K2F, BD #368861, BD Biosciences) tubes by a protocol approved by the departmental ethical board."

Please amend your current ethics statement to include the full name of the ethics committee/institutional review board(s) that approved your specific study.

Once you have amended this statement in the Methods section of the manuscript, please add the same text to the “Ethics Statement” field of the submission form (via “Edit Submission”).

For additional information about PLOS ONE ethical requirements for human subjects research, please refer to http://journals.plos.org/plosone/s/submission-guidelines#loc-human-subjects-research

5. Please include captions for your Supporting Information files at the end of your manuscript, and update any in-text citations to match accordingly. Please see our Supporting Information guidelines for more information: http://journals.plos.org/plosone/s/supporting-information.

[Note: HTML markup is below. Please do not edit.]

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

1. Is the manuscript technically sound, and do the data support the conclusions?

The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented.

Reviewer #1: Yes

Reviewer #2: Yes

**********

2. Has the statistical analysis been performed appropriately and rigorously?

Reviewer #1: Yes

Reviewer #2: No

**********

3. Have the authors made all data underlying the findings in their manuscript fully available?

The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.

Reviewer #1: Yes

Reviewer #2: Yes

**********

4. Is the manuscript presented in an intelligible fashion and written in standard English?

PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.

Reviewer #1: Yes

Reviewer #2: Yes

**********

5. Review Comments to the Author

Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)

Reviewer #1: Extracellular vesicles (EVs) have been extensively usedfor biomarker studies. It is expected that preanalytical processing methods of freshly draw blood may affect components of EV cargo. So far, however, few studies have evaluated such effect. To address this question, in this paper, Palviainen et al examined effect of anti-coagulation on isolated EV population and found significant increase on EV counts in serum when compared to plasma samples. Proteomics analysis showed significant differences between serum and plasma as well as among plasma samples with different anticoagulants. Results from the study enriches our knowledge on the effect of blood sample preparation methods on isolated EV characteristics. The manuscript is well-written, and the data are solid. It can be further improved by addressing the following questions:

1. The study mainly focused on difference. It will be beneficial to include scatter plots showing similarity (with r values) in commonly detected proteins.

2. Please provide a supplementary table showing proteomics data categorized by sample types (serum, different anticoagulants).

3. Keratin proteins are likely from contamination during sample preparation. A discussion on its origination should be added.

4. Discussion on limitation of the study should be added.

5. Figures are in bad quality in pdf file. High resolution in published manuscript is needed.

Reviewer #2: Palviainen and colleagues have conducted an interesting and useful work assessing how several anticoagulation reagents for plasma preparation and serum affect the concentration, cellular origin, and protein content of circulating extracellular vesicles (EV). The authors additionally and originally assessed, at least through bioinformatic methods, whether the detected protein cargo could include an EV protein signature resembling a reported protein corona from synthetic nanoparticles. The study is rigorous in its design, using state-of-the-art methods and it is clearly presented. However, there are several issues that need to be addressed to reach publication quality.

Major Issues:

1. The Statistical Analysis section (and statistical references throughout other items of the Materials and Methods section) needs major improvement. The authors need to clarify how they assessed the normality of the data before implementing ANOVA followed by Tukey tests, which assume normally distributed data. The statement “For multiple parameter analysis of non-normal distributed data Tukey multiple comparison test was used”, on line 194, is not accurate. What the authors need to do to handle comparisons of multiple groups of non-normal data is a transformation of the data to approximate normality before conducting an ANOVA test followed by the post-hoc Tukey test for multiple comparisons, or, alternatively, the implementation of a non-parametric test such as the Kruskal-Wallis test followed by appropriate post-hoc analysis such as the Dunn test. Additionally, information on the PCA approach is necessary.

2. Starting on page 18 of the result section “Protein cargo of the EV corona is modified by anticoagulation or its absence”, the authors described several comparisons with lists of proteins from published studies and claim (e.g., on line 322) that the overlap denote “marked similarities regarding the EV proteome”. For this claim to be justified, the statistical significance of the overlap between the different studies needs to be assessed. This can be done by calculating an empirical P value for the overlap among the protein lists based on simulation analyses. The simulation analysis would assess the probability of producing an equivalent random overlap between the published MP corona protein signatures (from the published studies) and a number of simulated protein lists (e.g., 1,000 or 10,000 simulated lists) that are generated by randomly selecting lists of proteins from Exocarta or EVpedia (with the simulated protein lists having the same length as the lists of experimentally detected EV proteins in this study). Only then could the overlap be claimed to be significant. The simulation analysis will reveal whether the detected overlap among the lists could have just happened by chance, therefore potentially not meaningful.\\

Minor Issues:

1. On line 90, the word “each” is misplaced.

2. Methods for EV isolation need to be better described. It is not clear what was the initial volume of pooled plasma or serum used for set I and II (the pellets of which were resuspended in 250 uL of PBS). It is not clear whether the elution from the SEC column was performed as a single elution step with 1 mL of PBS or whether there were multiple fractions collected.

3. Supplementary Figure 1 should be moved to the main text and significant digits used on Sup. Fig. 1A should be consistent.

4. Provide data table or representative NTA plots of size distributions for visual assessment of the size distribution differences instead of referring “data not shown” on line 215. This data could be included in the Supplementary Information document.

5. The statement “The generally upheld view of the EV field is that there are more platelet-derived “microparticles” or EVs, in serum than plasma,” on line 240 seems too subjective and needs a published reference. The sentence should be rephrased to more scientifically covey its meaning. The authors could instead write something similar as in the discussion section lines 348-349, e.g., “The fact that large EVs from serum have been shown to contain more platelet-derived microparticles than large EV from ACD plasma (7), prompted us to…”

6. Quality of all figures is unacceptably low. Replace figures with higher resolution versions.

7. Table 1 should go to Supplementary Information and columns ACD, Citrate, and EDTA clearly marked as P values.

8. The word “blotted” on line 275 should read “plotted”.

9. The statement: “At the moment, very few studies have addressed the factors (age, sex) which may affect EV concentrations in healthy populations”, on lines 362-363, requires citation(s) of some of the referenced studies.

**********

6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.

Reviewer #1: No

Reviewer #2: Yes: Richard Pratley, MD

[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files to be viewed.]

While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email us at figures@plos.org. Please note that Supporting Information files do not need this step.

PLoS One. 2020 Aug 19;15(8):e0236439. doi: 10.1371/journal.pone.0236439.r002

Author response to Decision Letter 0


14 Jun 2020

Response to reviewers

Reviewer #1: Extracellular vesicles (EVs) have been extensively used for biomarker studies. It is expected that preanalytical processing methods of freshly draw blood may affect components of EV cargo. So far, however, few studies have evaluated such effect. To address this question, in this paper, Palviainen et al examined effect of anti-coagulation on isolated EV population and found significant increase on EV counts in serum when compared to plasma samples. Proteomics analysis showed significant differences between serum and plasma as well as among plasma samples with different anticoagulants. Results from the study enriches our knowledge on the effect of blood sample preparation methods on isolated EV characteristics. The manuscript is well-written, and the data are solid. It can be further improved by addressing the following questions:

We would like to thank the reviewer for his or her positive remarks.

1. The study mainly focused on difference. It will be beneficial to include scatter plots showing similarity (with r values) in commonly detected proteins.

We thank the reviewer for this valuable comment. We have performed Pearson correlation analysis (as described in Methods lines 199-200), and results are presented in Results (lines 284-286) and Supplementary files (S5 table).

2. Please provide a supplementary table showing proteomics data categorized by sample types (serum, different anticoagulants).

We have now added the proteomics file as a Supplementary file (S4 table).

3. Keratin proteins are likely from contamination during sample preparation. A discussion on its origination should be added.

We agree that the majority of the identified keratins likely originate from exogenous sources, and this information has been added to the Legend text of Table 1.

4. Discussion on limitation of the study should be added.

We thank the reviewer for this valuable comment. We have now included the following limitations to the Discussion: the use of pooled samples, the use of differential ultracentrifugation, and the absence of analysis of the impact of the anticoagulation on the smallest EV. The comments have been integrated in the text and therefore the Discussion had to be rewritten and restructured to reorganize the text. The additions are highlighted.

5. Figures are in bad quality in pdf file. High resolution in published manuscript is needed.

We wholly agree with both reviewers. The cause is the PDF-generating system of the journal, which produces low-resolution files. All figures accessible through the separate downloadable link were and still are in high resolution. We have now rechecked that all the figures meet the requirements of the journal.

Reviewer #2: Palviainen and colleagues have conducted an interesting and useful work assessing how several anticoagulation reagents for plasma preparation and serum affect the concentration, cellular origin, and protein content of circulating extracellular vesicles (EV). The authors additionally and originally assessed, at least through bioinformatic methods, whether the detected protein cargo could include an EV protein signature resembling a reported protein corona from synthetic nanoparticles. The study is rigorous in its design, using state-of-the-art methods and it is clearly presented. However, there are several issues that need to be addressed to reach publication quality.

Major Issues:

1. The Statistical Analysis section (and statistical references throughout other items of the Materials and Methods section) needs major improvement. The authors need to clarify how they assessed the normality of the data before implementing ANOVA followed by Tukey tests, which assume normally distributed data. The statement “For multiple parameter analysis of non-normal distributed data Tukey multiple comparison test was used”, on line 194, is not accurate. What the authors need to do to handle comparisons of multiple groups of non-normal data is a transformation of the data to approximate normality before conducting an ANOVA test followed by the post-hoc Tukey test for multiple comparisons, or, alternatively, the implementation of a non-parametric test such as the Kruskal-Wallis test followed by appropriate post-hoc analysis such as the Dunn test. Additionally, information on the PCA approach is necessary.

We thank the reviewer for the comment and valuable suggestions. Accordingly, we have now tested the data of all experiments for normality using Saphiro-Wilk test, and based on the results analyzed the data of flu-SEC experiment with Tukey test, and the flow cytometry and proteomics data using Kruskall-Wallis test. The statistics-paragraph in the methods has been rephrased based on these changes (lines 192-201). In addition, PCA is now explained in more detail (lines 277-284).

Based on the new statistical analysis of proteomic data done with Kruskall-Wallis test followed by Dunn test (post-hoc), the results were slightly changed. 35 proteins showed significant difference between different sample types and this has now stated in lines 306-314) and table 1 has been now corrected accordingly.

2. Starting on page 18 of the result section “Protein cargo of the EV corona is modified by anticoagulation or its absence”, the authors described several comparisons with lists of proteins from published studies and claim (e.g., on line 322) that the overlap denote “marked similarities regarding the EV proteome”. For this claim to be justified, the statistical significance of the overlap between the different studies needs to be assessed. This can be done by calculating an empirical P value for the overlap among the protein lists based on simulation analyses. The simulation analysis would assess the probability of producing an equivalent random overlap between the published MP corona protein signatures (from the published studies) and a number of simulated protein lists (e.g., 1,000 or 10,000 simulated lists) that are generated by randomly selecting lists of proteins from Exocarta or EVpedia (with the simulated protein lists having the same length as the lists of experimentally detected EV proteins in this study). Only then could the overlap be claimed to be significant. The simulation analysis will reveal whether the detected overlap among the lists could have just happened by chance, therefore potentially not meaningful.

We thank the reviewer for the insightful comment and advice concerning performing a simulation analysis. Firstly, we would like to point out that by the chosen wording (e.g. “markedly” in the Abstract) we tried to highlight the novelty, but not statistical significance of our finding as this was the first report on the similarities of EVs and NPs that we are aware of. However, we looked into this suggestion and consulted the experts available to us. Although we agree that a simulation would be very interesting to perform, we feel that in the scope of the current study it is too extensive and difficult for us to do without experience and absence of help on the matter. We also find that the databases on EVs are not well-curated regarding the experimental methods (e.g. EV isolation), so comparison against a randomly produced datasets of very variable studies are likely not be meaningful. Therefore, based on the reviewer’s comment, we moderated our text as follows:

•the sentence in line 334-336 as following: “Based on the similarities of the EV proteome of our study and the two earlier studies using different isolation procedures, we hypothesize that there may be a common “EV protein corona”.

•the sentence in lines 399-400 was adjusted and the word “remarkable” was removed.

•in the Abstract “markedly” was removed, and the sentence now reads: “Comparison to other studies further revealed that the shared EV protein composition resembles the “protein corona” of synthetic nanoparticles incubated in plasma or serum.”

Finally, we were glad to discover a supporting publication from Simonsen and Münter, which was published while our work was being reviewed, which shares our concern about the similarities of NPs and EVs including the protein cargo they carry. “Pay attention to the biological nanoparticles when studying the protein corona on nanomedicines” (https://onlinelibrary.wiley.com/doi/abs/10.1002/anie.202004611). Although, the authors did not provide experimental data, we added this reference into the manuscript in the text (lines 406-407).

Minor Issues:

1. On line 90, the word “each” is misplaced.

The word has been removed.

2. Methods for EV isolation need to be better described. It is not clear what was the initial volume of pooled plasma or serum used for set I and II (the pellets of which were resuspended in 250 uL of PBS). It is not clear whether the elution from the SEC column was performed as a single elution step with 1 mL of PBS or whether there were multiple fractions collected.

The information on initial volumes of pooled samples for sets I and II is now added to the S1 table (workflow).

The elution from the SEC column was performed as a single elution step with 1 mL PBS. Column geometry and elution protocol was adapted from the application notes of PD MidiTrap G-25 columns (GE Healthcare), except that the stationary phase was replaced from Sephadex G-25 to Sepharose CL-2B. This protocol enables the separation of EVs from soluble proteins (e.g. albumin), but does not separate all lipoprotein particles. This has now been clarified in the manuscript (line 126).

3. Supplementary Figure 1 should be moved to the main text and significant digits used on Sup. Fig. 1A should be consistent.

S1 figure has now been corrected, but in our opinion the S1 figure serves its purpose for providing visual data of background data of the experiment best in the supplementary files.

4. Provide data table or representative NTA plots of size distributions for visual assessment of the size distribution differences instead of referring “data not shown” on line 215. This data could be included in the Supplementary Information document.

A Figure depicting size distributions has now been added to S1 figure (C) and the sentence in lines 218-221 has been corrected accordingly.

5. The statement “The generally upheld view of the EV field is that there are more platelet-derived “microparticles” or EVs, in serum than plasma,” on line 240 seems too subjective and needs a published reference. The sentence should be rephrased to more scientifically covey its meaning. The authors could instead write something similar as in the discussion section lines 348-349, e.g., “The fact that large EVs from serum have been shown to contain more platelet-derived microparticles than large EV from ACD plasma (7), prompted us to…”

We thank the reviewer for this suggestion. The sentence has now been edited (lines 243-244).

6. Quality of all figures is unacceptably low. Replace figures with higher resolution versions.

Unfortunately, the PDF-file that the journal automatically creates contains a low-resolution version of the figures. All the figures were downloadable in high resolution format for the review from a separate toggle. We have rechecked and all figures meet the requirements of the journal.

7. Table 1 should go to Supplementary Information and columns ACD, Citrate, and EDTA clearly marked as P values.

We are happy to remove the Table to Supplementary files if the reviewer insists that this will improve the paper. However, we would prefer to keep it in the main text, so that the information of the corona proteins would be easily accessible to the readers, which is not the case with separate supplementary information which is often accessed only a few people. We would like the readers to reflect on the meaning and impact of the selection of the corona proteins on EVs. Table 1 has been corrected after the new statistical analysis with Kruskall-Wallis test followed with Dunn´s test. As reviewer has suggested, the columns ACD, Citrate and Serum has now been marked with “p-value”.

8. The word “blotted” on line 275 should read “plotted”.

Corrected

9. The statement: “At the moment, very few studies have addressed the factors (age, sex) which may affect EV concentrations in healthy populations”, on lines 362-363, requires citation(s) of some of the referenced studies.

We have added three references (lines 375-380): Eitan et al., Age-related changes in plasma extracellular vesicle characteristics and internalization by leukocytes. Scientific Reports 2017, Arraud et al., Extracellular vesicles from blood plasma: determination of their morphology, size, phenotype and concentration. Journal of thrombosis and haemostasis 2014, and Frühbeis et al., Physical exercise induces rapid release of small extracellular vesicles into the circulation. Journal of extracellular vesicles 2015.

Attachment

Submitted filename: Responce to Reviewers.docx

Decision Letter 1

John Matthew Koomen

8 Jul 2020

Extracellular vesicles from human plasma and serum are carriers of extravesicular cargo ─ implications for biomarker discovery

PONE-D-20-08075R1

Dear Dr. Siljander,

We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements.

Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication.

An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org.

If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org.

Kind regards,

John Matthew Koomen, PhD

Academic Editor

PLOS ONE

Additional Editor Comments (optional):

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation.

Reviewer #1: All comments have been addressed

Reviewer #2: All comments have been addressed

**********

2. Is the manuscript technically sound, and do the data support the conclusions?

The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented.

Reviewer #1: Yes

Reviewer #2: Yes

**********

3. Has the statistical analysis been performed appropriately and rigorously?

Reviewer #1: Yes

Reviewer #2: Yes

**********

4. Have the authors made all data underlying the findings in their manuscript fully available?

The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.

Reviewer #1: Yes

Reviewer #2: Yes

**********

5. Is the manuscript presented in an intelligible fashion and written in standard English?

PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.

Reviewer #1: Yes

Reviewer #2: Yes

**********

6. Review Comments to the Author

Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)

Reviewer #1: The authors have satisfactorily addressed my comments. The data presented will fill some knowledge gap in EV research.

Reviewer #2: (No Response)

**********

7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.

Reviewer #1: Yes: Liang Wang

Reviewer #2: Yes: Richard Pratley, MD

Acceptance letter

John Matthew Koomen

24 Jul 2020

PONE-D-20-08075R1

Extracellular vesicles from human plasma and serum are carriers of extravesicular cargo ─ implications for biomarker discovery

Dear Dr. Siljander:

I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department.

If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org.

If we can help with anything else, please email us at plosone@plos.org.

Thank you for submitting your work to PLOS ONE and supporting open access.

Kind regards,

PLOS ONE Editorial Office Staff

on behalf of

Dr. John Matthew Koomen

Academic Editor

PLOS ONE

Associated Data

    This section collects any data citations, data availability statements, or supplementary materials included in this article.

    Supplementary Materials

    S1 Raw images

    (PDF)

    S1 Fig. General characterization of plasma and serum–derived EVs.

    (JPG)

    S1 Table. Workflow of the study.

    (DOCX)

    S2 Table. Flow cytometry analysis of plasma and serum–derived EVs.

    (DOCX)

    S3 Table. Flu-SEC analysis of plasma and serum–derived EVs.

    (DOCX)

    S4 Table. Identified and quantified proteins.

    (XLSX)

    S5 Table. Pearson correlation matrix of identified and quantified proteins.

    (XLSX)

    S6 Table. A gene ontology analysis of “EV corona proteins”.

    (DOCX)

    S7 Table. A gene ontology analysis of “NP and EV corona proteins”.

    (DOCX)

    Attachment

    Submitted filename: Responce to Reviewers.docx

    Data Availability Statement

    All proteomic data files are available from the PRIDE database (accession number PXD015375).


    Articles from PLoS ONE are provided here courtesy of PLOS

    RESOURCES