Skip to main content
BMC Infectious Diseases logoLink to BMC Infectious Diseases
. 2020 Aug 27;20:637. doi: 10.1186/s12879-020-05360-5

Increased physiological dead space in mechanically ventilated COVID-19 patients recovering from severe acute respiratory distress syndrome: a case report

Jingen Xia 1,2, Yingying Feng 1, Min Li 1, Xin Yu 1, Yi Zhang 1, Jun Duan 3, Qingyuan Zhan 1,
PMCID: PMC7450943  PMID: 32854630

Abstract

Background

An ongoing outbreak of coronavirus disease 2019 (COVID-19) is spreading globally. Recently, several articles have mentioned that the early acute respiratory distress syndrome (ARDS) caused by COVID-19 significantly differ from those of ARDS due to other causes. Actually, we newly observed that some mechanically ventilated COVID-19 patients recovering from severe ARDS (more than 14 days after invasive ventilation) often experienced evidently gradual increases in CO2 retention and minute ventilation. However, the underlying mechanics remain unclear.

Case presentation

To explain these pathophysiological features and discuss the ventilatory strategy during the late phase of severe ARDS in COVID-19 patients, we first used a metabolic module on a General Electric R860 ventilator (Engstrom Carestation; GE Healthcare, USA) to monitor parameters related to gas metabolism, lung mechanics and physiological dead space in two COVID-19 patients. We found that remarkably decreased ventilatory efficiency (e.g., the ratio of dead space to tidal volume 70–80%, arterial to end-tidal CO2 difference 18–23 mmHg and ventilatory ratio 3–4) and hypermetabolism (oxygen consumption 300–400 ml/min, CO2 elimination 200–300 ml/min) may explain why these patients experienced more severe respiratory distress and CO2 retention in the late phase of ARDS caused by COVID-19.

Conclusion

During the recovery period of ARDS among mechanically-ventilated COVID-19 patients, attention should be paid to the monitoring of physiological dead space and metabolism. Tidal volume (8–9 ml/kg) could be increased appropriately under the limited plateau pressure; however, barotrauma should still be kept in mind.

Keywords: Coronavirus disease 2019, Acute respiratory distress syndrome, Dead space ventilation, Mechanical ventilation, Case report

Background

An ongoing outbreak of coronavirus disease 2019 (COVID-19) is spreading globally [1, 2]. As of April 29, 2020, the number of total confirmed cases has exceeded 3 million, associated to 207,973 deaths worldwide [1]. Recently, several articles [35] have reported that the early acute respiratory distress syndrome (ARDS) caused by coronavirus disease 2019 (COVID-19) significantly differ from those of ARDS due to other causes, such as mismatch between changes in respiratory mechanics and severity of impaired oxygenation [3], significantly decreased ventilation efficiency [4], and lower lung recruitability [5]. We also found that many mechanically ventilated COVID-19 patients recovering from severe ARDS experienced gradual increases in CO2 retention and minute ventilation (MV). To explain these pathophysiological features and discuss the ventilatory strategy during the late phase of severe ARDS in COVID-19 patients, we first used a metabolic module (COVX module; GE Healthcare, Helsinki, Finland) on a General Electric R860 ventilator (Engstrom Carestation; GE Healthcare, USA) to monitor parameters related to gas metabolism, end-expiratory lung volume (EELV), physiological dead space, ventilatory ratio (VR) [4], and lung mechanics in two COVID-19 patients.

Case presentation

Case 1: A 70-year-old woman (BMI, 21.5 kg/m2) with acute respiratory failure caused by COVID-19 was transferred to Tongji Hospital (Wuhan, China) on February 26, 2020. On admission, she had severe dyspnea (respiratory rate [RR], 40 bpm) and acute hypoxemic respiratory failure (oxygen saturation 45% with oxygen flow 12 L/min) and underwent endotracheal intubation immediately. A tracheotomy was performed 6 days post-admission. She was supported in pressure control mode: inspiratory pressure 15–18 cmH2O and positive end-expiratory pressure (PEEP) 6–8 cmH2O. About 14 days post-admission, she experienced a gradual increase in RR (from 25 to 30–40 bpm), tidal volume (VT, from 410 to 480 ml [7.6–9.1 ml/kg PBW]), and MV (from 10 to 12–15 L/min), accompanied by an increased PaCO2 (from 39 to 47–60 mmHg) and decreased oxygenation (arterial partial pressure of oxygen [PaO2]/fraction of inspired oxygen [FiO2], from 127 to 74–100 mmHg; FiO2, from 0.5 to 0.7). On day 15, the ventilator was changed to an R860 ventilator with COVX module. The following data were recorded: oxygen consumption (VO2) 280 ml/min, CO2 elimination (VCO2) 175 ml/min; ratio of dead space to VT (VD/VT) 78%, end-tidal carbon dioxide (ETCO2) 26.1 mmHg, arterial to end-tidal CO2 difference (P(a-ET)CO2) 22.3 mmHg, VR 3.57; EELV 1672 ml; airway resistance (R) 10.8 cmH2O/L/s, and respiratory system compliance (Cresp) 12.5 ml/cmH2O. Chest computed tomography (CT) revealed bilateral diffuse ground glass opacity, interstitial fibrosis, traction bronchiectasis, and a small amount of consolidation in the dependent aspects of the lungs on 2 day and 19 day after admission (Fig. 1). Forty days after admission, her lung function still did not recover from sustained hypercapnia in the treatment of Lopinavir/ritonavir, infusion of convalescent plasma, low molecular weight heparin and prone position ventilation, and was transferred to another hospital.

Fig. 1.

Fig. 1

Left: transverse chest CT images from a 70-year-old female COVID-19 patient showing bilateral diffuse ground glass opacity, interstitial fibrosis, traction bronchiectasis and a small amount of lung consolidation in the dependent lungs on 2 and 19 days after invasive ventilation. Right: transverse chest CT images from a 42-year-old male COVID-19 patient showing bilateral ground glass opacity, interstitial fibrosis, left pleural effusion and traction bronchiectasis on 36 days and 48 days after invasive ventilation

Case 2: A 42-year-old man (BMI, 22.9 kg/m2) diagnosed with COVID-19 was transferred to Tongji Hospital (Wuhan, China) on March 3, 2020. Tracheal intubation and venous-venous extracorporeal membrane oxygenation (ECMO) were performed 25 and 24 days, respectively, before admission due to severe refractory ARDS. ECMO catheters were removed after 14 days of treatment due to a severe blood stream infection. However, ECMO was performed again due to bilateral pneumothorax 8 days before admission. Post-admission, he was treated with antiviral therapy, antibiotic therapy, tracheotomy (1 day post-admission), prone ventilation, and other treatments using our standard protocol. Oxygenation improved gradually, and the ECMO catheter was removed again 19 days post-admission. Over the next week, he showed a gradual increase in MV and hypercapnia. On day 26 post-admission, he was ventilated mechanically in pressure support mode: pressure support 18 cmH2O, PEEP 3 cmH2O, FiO2 0.3, VT 651 ml (9.2 ml/kg), RR 31 bpm, and MV 17.9 L/min. Arterial blood gas revealed the following: pH 7.463, PaCO2 51 mmHg, PaO2 80.4 mmHg, HCO3 34.9 mmol/L, and PaO2/FiO2 268 mmHg. The following data were recorded using the COVX module: VO2 401 ml/min, VCO2 292 ml/min; VD/VT 76%, ETCO2 33.2 mmHg, P(a-ET)CO2 17.8 mmHg, VR 3.4; EELV 1000 ml; R 7.7 cmH2O/L/s and Cresp 19.6 ml/cmH2O. Chest CT showed bilateral ground glass opacity, interstitial fibrosis, and traction bronchiectasis 11 days and 23 days post-admission (Fig. 1). He was disconnected from invasive ventilator and transferred to another hospital for further pulmonary rehabilitation on 38 days post-admission.

Discussion and conclusion

We found that the lung tissue of COVID-19 patients recovering from severe ARDS not only reflects the typical characteristics of late-phase ARDS (reduced lung compliance, pulmonary fibrosis, and decreased EELV) but is also associated with a significantly increased dead space (VD/VT 70–80%, VR 3–4), markedly higher than that in patients with severe ARDS due to other reasons [6]. Besides, some COVID-19 patients show an obvious hypermetabolic status even in the recovery period. Therefore, significantly decreased ventilation efficiency and hypermetabolism may explain why these patients experienced more severe respiratory distress and CO2 retention in the late phase of ARDS.

A remarkably increased physiological dead space may be a prominent pathophysiological feature in mechanically ventilated COVID-19 patients recovering from severe ARDS; however, the underlying mechanism remains unclear. It may be related to significant regional ventilation/perfusion heterogeneity [7] due to loss of lung perfusion regulation and hypoxic vasoconstriction [3], pulmonary microthrombosis [8], and increased anatomical dead space from obvious traction bronchiectasis observed on chest CT.

To reduce the risk of ventilator-induced lung injury with high tidal volume (8–9 ml/kg), we tried to reduce the VT (6–8 ml/kg) and increase the RR to maintain the MV. However, severe hypercapnia (PaCO2 98 mmHg, pH 7.10 in case 2) was observed, and the use of sedatives and anesthetic agents had to be increased. These serious consequences are worthy of attention. In these two patients, we set a higher VT (8–9 ml/kg), lower peak airway pressure (< 25 cmH2O), and low PEEP levels (3–6 cmH2O) due to low lung recruitability; barotrauma did not occur. Of course, our experience from few patients cannot be extrapolated to all COVID-19 patients, however, this report provides a possible more suitable lung protective ventilation for COVID-19 patients recovering from acute respiratory failure with refractory hypercapnia, which deserved to be further investigated in clinical research.

In conclusion, during the recovery period of ARDS in mechanically ventilated COVID-19 patients, attention should be paid to the monitoring of physiological dead space and VR [4]. Tidal volume (8–9 ml/kg) could be increased appropriately under the limited plateau pressure; however, barotrauma should still be considered. In theory, extracorporeal CO2 removal is a better choice for these patients [9] and will be more beneficial to reduce lung injury while awaiting lung tissue repair; however, further clinical investigations are warranted.

Acknowledgements

This work was supported by Zhejiang University special scientific research fund for COVID-19 prevention and control (No. 2020XGZX008); National Key Research and Development Program of China (No. 2016YFC1304300); National Natural Science Foundation of China (No. 81870072); CAMS Innovation Fund for Medical Sciences (No. 2018-I2M-1-003) and Non-profit Central Research Institute Fund of CAMS (No. 2019TX320006).

Abbreviations

ARDS

Acute respiratory distress syndrome

Cresp

Respiratory system compliance

COVID-19

Coronavirus disease 2019

CT

Computed tomography

ECMO

Extracorporeal membrane oxygenation

EELV

End-expiratory lung volume

FiO2

Fraction of inspired oxygen

MV

Minute ventilation

PaCO2

Arterial partial pressure of carbon dioxide

P(a-ET)CO2

Arterial to end-tidal CO2 difference

PaO2

Arterial partial pressure of oxygen

PEEP

Positive end-expiratory pressure

R

Airway resistance

RR

Respiratory rate

VD/VT

Ratio of dead space to VT

VR

Ventilatory ratio

VT

Tidal volume

VO2

Oxygen consumption

VCO2

CO2 elimination

Authors’ contributions

All authors contributed to the design and conception of the study and performed medical treatment for these two patients; The first draft of the manuscript was written by JX, YF, ML and XY; YZ, JD and QZ revised the manuscript. All authors read and approved the final version of the manuscript.

Funding

The authors have not received money, gifts, or other compensation from any organization, institution, or business that may be affected financially by our publication.

Availability of data and materials

Not applicable.

Ethics approval and consent to participate

The study was approved by the ethics committee of China-Japan Friendship Hospital (2020–21-K16).

Consent for publication

Both of the patients gave written consent for their personal or clinical details along with any identifying images to be published in this study. A copy of the written consent is available for review by the Editor-in-Chief of this journal.

Competing interests

The authors declare that they have no competing interests.

Footnotes

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.Di Gennaro F, Pizzol D, Marotta C, Antunes M, Racalbuto V, Veronese N, et al. Coronavirus diseases (COVID-19) current status and future perspectives: a narrative review. Int J Environ Res Public Health. 2020;17(8):2690. doi: 10.3390/ijerph17082690. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.World Health Organization. https://www.who.int/docs/default-source/coronaviruse/situation-reports/20200429-sitrep-100-covid-19.pdf?sfvrsn=bbfbf3d1_6 (accessed on 11 March 2020).
  • 3.Gattinoni L, Coppola S, Cressoni M, Busana M, Rossi S, Chiumello D. Covid-19 does not Lead to a “typical” acute respiratory distress syndrome. Am J Respir Crit Care Med. 2020;201:1299–1300. doi: 10.1164/rccm.202003-0817LE. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Liu X, Liu X, Xu Y, Xu Z, Huang Y, Chen S, et al. Ventilatory ratio in Hypercapnic mechanically ventilated patients with COVID-19 associated ARDS. Am J Respir Crit Care Med. 2020;201:1297–1299. doi: 10.1164/rccm.202002-0373LE. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Pan C, Chen L, Lu C, Zhang W, Xia JA, Sklar MC, et al. Lung Recruitability in SARS-CoV-2 associated acute respiratory distress syndrome: a single-center, observational study. Am J Respir Crit Care Med. 2020;201:1294–1297. doi: 10.1164/rccm.202003-0527LE. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Henderson WR, Chen L, Amato MBP, Brochard LJ. Fifty years of research in ARDS. Respiratory mechanics in acute respiratory distress syndrome. Am J Respir Crit Care Med. 2017;196:822–833. doi: 10.1164/rccm.201612-2495CI. [DOI] [PubMed] [Google Scholar]
  • 7.Robertson HT. Dead space: the physiology of wasted ventilation. Eur Respir J. 2015;45:1704–1716. doi: 10.1183/09031936.00137614. [DOI] [PubMed] [Google Scholar]
  • 8.Nuckton TJ, Alonso JA, Kallet RH, Daniel BM, Pittet JF, Eisner MD, et al. Pulmonary dead-space fraction as a risk factor for death in the acute respiratory distress syndrome. N Engl J Med. 2002;346:1281–1286. doi: 10.1056/NEJMoa012835. [DOI] [PubMed] [Google Scholar]
  • 9.Goligher EC, Amato MBP, Slutsky AS. Applying precision medicine to trial design using physiology. Extracorporeal CO2 removal for acute respiratory distress syndrome. Am J Respir Crit Care Med. 2017;196:558–568. doi: 10.1164/rccm.201701-0248CP. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

Not applicable.


Articles from BMC Infectious Diseases are provided here courtesy of BMC

RESOURCES