. 2020 Sep 23;15(9):e0239562. doi: 10.1371/journal.pone.0239562

A semi-automated method for unbiased alveolar morphometry: Validation in a bronchopulmonary dysplasia model

Thomas Salaets 1,2,*, Bieke Tack 3,4, André Gie 1, Benjamin Pavie 5, Nikhil Sindhwani 1, Julio Jimenez 6, Yannick Regin 1, Karel Allegaert 7,8, Jan Deprest 1,9,10, Jaan Toelen 1,2
Editor: Michael Koval11
PMCID: PMC7511023  PMID: 32966330

Abstract

Reproducible and unbiased methods to quantify alveolar structure are important for research on many lung diseases. However, manually estimating alveolar structure through stereology is time consuming and inter-observer variability is high. The objective of this work was to develop and validate a fast, reproducible and accurate (semi-)automatic alternative. A FIJI-macro was designed that automatically segments lung images to binary masks, and counts the number of test points falling on tissue and the number of intersections of the air-tissue interface with a set of test lines. Manual selection remains necessary for the recognition of non-parenchymal tissue and alveolar exudates. Volume density of alveolar septa (VVsep) and mean linear intercept of the airspaces (Lm) as measured by the macro were compared to theoretical values for 11 artificial test images and to manually counted values for 17 lungs slides using linear regression and Bland-Altman plots. Inter-observer agreement between 3 observers, measuring 8 lungs both manually and automatically, was assessed using intraclass correlation coefficients (ICC). VVsep and Lm measured by the macro closely approached theoretical values for artificial test images (R2 of 0.9750 and 0.9573 and bias of 0.34% and 8.7%). The macro data in lungs were slightly higher for VVsep and slightly lower for Lm in comparison to manually counted values (R2 of 0.8262 and 0.8288 and bias of -6.0% and 12.1%). Visually, semi-automatic segmentation was accurate. Most importantly, manually counted VVsep and Lm had only moderate to good inter-observer agreement (ICC 0.859 and 0.643), but agreements were excellent for semi-automatically counted values (ICC 0.956 and 0.900). This semi-automatic method provides accurate and highly reproducible alveolar morphometry results. Future efforts should focus on refining methods for automatic detection of non-parenchymal tissue or exudates, and for assessment of lung structure on 3D reconstructions of lungs scanned with microCT.

Introduction

During normal in utero lung development, large saccular airway structures with thick walls, evolve into smaller thin-walled alveoli through a process called secondary septation [1]. This process increases the total amount of surface available for gas exchange, and continues into adolescence [2]. During aging, alveolar size increases and surface area decreases again by coalescence [3]. Several diseases are known to affect alveolar structure. Bronchopulmonary dysplasia (BPD) for instance is characterized by larger alveoli, with thick septa [4]. Emphysema results in larger alveoli and a decreased total alveolar surface area [5], while fibrosis locally increases septal wall thickness [6]. The alveolar structural changes are often used as primary read-outs in preclinical research on these diseases. Reproducible and unbiased methods to quantify alveolar structure are of uttermost importance for the quality of this research.

The gold standard in quantification of structure is stereology. Stereology is a set of probabilistic methods used to define the physical properties of an irregular 3D structure based on 2D transsections through the structure. It has been used in lungs to estimate volumes, areas and numbers, in an unbiased way that is free of assumptions regarding size, shape or orientation of the structures [7]. Regarding lung structure, the most commonly used read-out is the mean linear intercept of the airspaces [8], reflecting the volume to surface-ratio of the airspaces (Lm). Proper determination of Lm includes manual point and intersection counting of septal tissue on a high number of test points and lines [9]. Using the same septal point and intersection counts, also alveolar surface area and septal tissue or air volumes can be estimated [7].

Manual counting is very time consuming and our experience (presented in this paper) suggests important inter-observer variability. Methods to automate or facilitate counting for alveolar morphometry (sometimes compatible with a stereological approach) have been developed. STEPanizer© is a free tool that loads test systems on digital images, but still involves manual counting [10]. More recently a system for automated high–throughput analysis of whole lung slides was described, however it requires specific software [11]. Plugins or macros for freely available software to count individual fields have also been developed [1214]. The common disadvantage of all these automated counting methods is that they do not discriminate large airways and blood vessels from lung parenchyma, and exudates or debris from septal tissue. The inability to filter out non-parenchyma or recognize inflammatory exudates leads to a significant bias of morphometric results.

The objective of this work was to develop and validate a fast, reproducible and accurate semi-automated method for counting of septal tissue points and intersections, which can be used to quantify alveolar surface area and volume, as well as mean linear intercept (Lm).

Materials and methods

Macro

A FIJI-macro [15] was designed that automatically counts the number of test points falling on reference tissue (parenchymal lung tissue, excluding conductive airways and vessels; Pref) or septal tissue (in contrast to air; Psep), and the number of intersections of the air-tissue interface (I) with a test line system. This macro automates the process of manual counting. The detection of non-reference tissue such as conductive airways, arteries, veins, pleura is still based on manual selection. In contrast, the detection of septal tissue is based on automatic thresholding, although exudates in the alveolar spaces had to be selected manually. The user has to manually define the threshold between tissue and air only in the first image of a batch (under the critical assumption that in each set of tissues are comparably processed, stained and images acquired using the same microscope settings). The macro is developed for batches of lung fields of 500x500μm, in PNG-format.

The image processing and analysis sequence that is automatically followed for all PNG-images in a folder, is briefly described below and summarized in Fig 1.

Fig 1. Summary of image processing and analysis from lung field to Pref, Psep and I*.

Fig 1

(A) Non-parenchymal tissue (in this case conductive airway) is selected manually. (B) Pref is counted as the number of points of a 64 point test grid, outside the selection of non-parenchymal tissue. (C) Image is thresholded to binary mask. (D) Automatically all small and unconnected exudates are removed. (E) Larger and connected exudates require manual selection. (F) Mask is cleaned and smoothened. (G) Psep is counted as the number of points of the test grid that are common to the cleaned mask. (H) The edges of the cleaned mask are aligned. (I-J) I is counted as the number of intersections of a test system of 8 horizontal and 8 vertical lines with the edge-image. *Pref = reference points, Psep = septal points, I = intersections.

  • Resizing of the image to 680x680 pixels (pixel resolution of 0,735μm) to match the test system.

  • Manual selection of the non-parenchymal tissue (conductive airways, arteries and veins) using a freehand selection tool (Fig 1A).

  • Deletion of the points matching the non-parenchymal tissue on a quadratic test system of 64 points on a central counting area of 567x567μm. Counting of the remaining points in the grid: Pref (Fig 1B).

  • Processing of the image to an 8-bit image and subsequently to a binary mask of tissue versus air by applying the user-defined threshold (Fig 1C).

  • Automatical detection of exudates, as unconnected particles of 0 to 1000 pixels that do not overlap with the border of the image and removal from the mask (Fig 1D).

  • Visual removal of the automatically detected exudates from a duplicated original image. Manual selection of the exudates that were not automatically detected (too large or in contact with septal tissue) and removal from the mask (Fig 1E).

  • Cleaning of the mask, by filling white particles of 1 to 200 pixels within the septal tissue, by removal of outliers and by a dilate-erode sequence (Fig 1F).

  • Calculation of a binary image containing all pixels that are black in both the clean mask and the test grid without the non-parenchymal points. Counting of the number of 1-pixel particles: Psep (Fig 1G).

  • Determination of the edges of the mask and creation of an edge image (Fig 1H).

  • Calculation of a binary image containing all pixels that are black in both the edge image and an image of 8 horizontal (Fig 1I) and then 8 vertical lines (Fig 1J) of 567 pixels (unit length d = 104μm or 141.75 pixels). Counting of the number of particles of both the horizontal and vertical image: I.

The macro generates one.csv file containing Pref, Psep and I for every lung field. It also automatically saves intermediate images and selections for a possible visual check. The macro (S1 File, morphometry_v4.0.ijm) is available for download with this paper, together with a user manual (S2 File) and a second macro that can be used for checking the accuracy of the algorithm in batch (S3 File, checkmorphometry_v4.0.ijm).

Artificial test images

To test and validate the counting procedure in the macro, a set of artificial binary images was made in FIJI. All images were 2040x2040 pixels and were composed of wallpaper-like repetitions of a combination of geometric figures for which surface and perimeter can be calculated. Within each square-shaped repetition the geometric figures (in white) were randomly organized against a black background. Based on the surface and perimeter of the geometric figures, a theoretical “septal volume” density (VVsep) and mean linear intercept of the geometric “airspaces” (Lm) could be calculated.

VVsep=20402surfacegeometricfigures20402
Lm=4*(1VVsep)perimetergeometricfigures

Twenty (partially overlapping) fields of 680x680 pixels were randomly extracted using the results of a random number generator as coordinates. An example is shown in Fig 2A. These 20 fields were automatically counted using a slightly modified version of the macro that omitted the steps converting a color image to a cleaned binary mask.

Fig 2. Validation on artificial images.

Fig 2

(A) Illustration of an artificial test image with sampling strategy. (B-C) Macro results for VVsep * and Lm† plotted against the theoretical values. The regression line is plotted in red, dashed line represents identity (y = x). (D-E) Bland-Altman plots for VVsep * and Lm† plot the relative difference [(theoretical–macro)/average] to the average result. Red line indicates bias, with confidence interval (dashed red line). *volume density of alveolar septa (VVsep); †mean linear intercept of the airspaces (Lm).

Lung images

Lung slides were obtained from previous experiments in the preterm rabbit model for BPD [16, 17]. Briefly, pregnant rabbit dams underwent cesarean section on day 28 of gestation, (normal gestation is 31 days). Preterm rabbit pups were raised in an incubator with controlled temperature and humidity, in either normoxia (N; 21% O2) or hyperoxia (H; 95% O2). Pups were hand-fed, twice daily, by gavage, using a milk replacer appropriate for rabbits. Colostrum and probiotics were added to the feeding. Vitamin K was supplemented intramuscularly, and antibiotics were administered to prevent infections. On day 7 pups were euthanized. Experiments were approved by the Ethical Committee for Animal Research at KULeuven as P059/2016.

Lungs of preterm rabbits on day 7 were harvested “en-bloc” after thoracotomy, with the trachea and carina intact. Right bronchus was ligated and right lungs removed for other purposes. A 20G catheter was inserted and fixed in the trachea, through which the left lung was connected to a pump filled with paraformaldehyde 4%, delivering a constant hydrostatic pressure of 25cmH2O. For 24h, the left lung was kept in a bath for immersion fixation, while connected to the system for pressure-fixation. Afterwards lungs were rinsed in phosphate buffered saline, dehydrated in ethanol and embedded in paraffin as a whole. Sagittal 5μm thick microtome sections were made and stained with hematoxylin and eosin.

Lung slides were scanned with a whole slide scanner (Axio Scan® Slide Scanner, Zen Zeiss, Oberkochen, Germany), generating 1 CZI-file for each whole lung slide. A customized Groovy Script for FIJI randomly sampled 20 fields of 500x500μm within the edges of the lung tissue, and exported them as PNG-images. The Groovy Script for random sampling can be found in S4 File (extract_some_tiles_from_tissue_czi_v02.groovy). An example of the lung sampling is shown in Fig 3A.

Fig 3. Validation on lung images.

Fig 3

(A) Illustration of a lung slide with sampling strategy. (B-C) Macro results for VVsep * and Lm† plotted against the manual values. The regression line is plotted in red, dashed line represents identity (y = x). (D-E) Bland-Altman plots for VVsep * and Lm† plot the relative difference [(manual–macro)/average] to the average result. Red line indicates bias, with confidence interval (dashed red line). *volume density of alveolar septa (VVsep); †mean linear intercept of the airspaces (Lm).

Manual counting

The results of semi-automatic counting with the FIJI-macro were compared to manual counting, the current gold standard. The same 20 lung fields were converted to JPG-images for counting with STEPanizer [10]. A quadratic test system of 64 points and 8 horizontal and 8 vertical lines with a total length of 6670μm (d = 104 μm) was used, with an equal length and position as the test system in the macro [18]. The points falling on non-parenchymal tissue (Pnon-par), Psep and I were manually counted.

Morphometric read-outs

Volume density of alveolar septa (VVsep) and mean linear intercept of the airspaces (Lm) of each test image or lung slide was calculated using the following formulas, according to the guidelines for quantitative assessment of lung structure of the American Thoracic Society [7]:

Pref=64Pnonpar
VVsep=PsepPref
Lm=2*d*PrefPsepI

Other read-outs such as mean transsectional wall length (Lmw) [19] and the surface area density of the air spaces (SVair) [7, 18] can also be calculated based on Pref, Psep and I. When the total lung volume is available, volume and surface density can be converted to absolute volume (Vsep) and surface (S), respectively. For the purpose of validation of the counting macro, we only focused on VVsep as a read-out based on point counting alone, and Lm as a read-out based on both point and intersection counting.

Validation

For validation, we first tested the macro on a set of 11 artificial test images, and compared the automatically calculated VVsep and Lm to the theoretical values. On lung images, VVsep and Lm were determined both manually and semi-automatically by a single observer for a set of fields from 17 lungs (of which 5 and 7 in plain normoxia and hyperoxia conditions respectively) and by 3 independent observers for a set of 8 lungs. The manual selection of non-parenchymal tissue and exudates in the semi-automatic macro was done independently by each of the 3 observers. Semi-automatic results of 17 lungs were compared to manual results for a single observer. The results of the 3 observers were used for assessment of inter-observer agreement (reproducibility).

Results were compared by means of linear regression and Bland-Altman plots using GraphPad Prism® 7.0 software (GraphPad, La Jolla, California, USA). We report R2-values, a best-fit equation for the regression line and relative bias (with confidence interval) derived from the Bland-Altman plots. We calculated ICC (two way random effects model for absolute agreement) using SPSS® version 25 (IBM, Armonk, New York, USA) for inter-observer agreement between the 3 observers [20]. Results from an N and H group were compared by a t-test with Welch correction for unequal variance.

Results

Artificial test images

We observed a very strong correlation between the results of the macro and the theoretical results of the artificial test images. For VVsep R2 was 0.9750 and the trend line was almost on the identity line (Y = 0.9824*X + 0.006889; Fig 2B). Bias was -0.35% (CI -8.2–7.5%; Fig 2D). For Lm R2 was 0.9573 and the trend line was close to identity (Y = 1.000*X– 5.230; Fig 2C). The Bland-Altman plot confirmed an underestimation by the macro with a bias of -8.7% (CI -34.7–17.2%; Fig 2E).

Lung images

For the lung images, the correlation between manual counting and the macro was less strong (Fig 3), despite the use of exactly the same fields and exactly the same test system for both manual and semi-automatic counting. R2 was 0.8262 for VVsep with semi-automatic results that somewhat overestimated the manual values (Y = 1.137*X—0.01488; Fig 3B). Overestimation was confirmed by a bias of 6.0% (CI -6.9–18.9%; Fig 3D). Almost always, counting with the macro resulted in a higher number of septal points (Psep) in comparison to manually counting. For Lm R2 was 0.8288, but the trend line indicated a considerable underestimation of Lm (Y = 0.5494*X + 21.89; Fig 3C) in comparison to the manual gold standard. The Bland-Altman plot in Fig 3E confirms underestimation of Lm with a bias of -12.1% (CI -23.5 –-0.6%). In general, overlaying the cleaned edge image over the original lung field reveals accurate automatic segmentation of the septal tissue (Fig 4).

Fig 4. Illustration of a semi-automatically segmented lung image, with overlaid test system.

Fig 4

Central white zone hides a manually selected vascular structure. Crossing points not falling on the vascular structure are counted as Pref, crossing points falling on septal tissue are counted as Psep and intersections of the test lines with the blue line indicating the edge of the septal tissue are counted as I.

Reproducibility

Evaluation of inter-observer agreement of the manual results demonstrates an ICC of 0.859 (good agreement) for VVsep and 0.643 (moderate agreement) for Lm. ICC increased when the semi-automatic method was used, indicating improved reproducibility. With the semi-automatic method, ICC for VVsep was 0.956, while 0.900 for Lm (both excellent agreement). Pairwise comparisons between observers are shown in S1 Fig. For the manual results it becomes apparent that repetition of counting by another observer results in random error, but for Lm also in an important systematic error (over- or underestimation). Use of the macro decreases random differences overall and decreases systematic inter-observer error in the Lm-results. For VVsep in 2/3 cases it increased systematic error, however to an arguably irrelevant extent.

Comparison of normoxia and hyperoxia results

Both VVsep and Lm discriminate lungs of pups raised in normoxia and hyperoxia. Manually counted VVsep tends to increase in hyperoxia (p = 0.06) and Lm increases (p = 0.01). Use of the macro results in comparable differences between the groups: p = 0.01 and p = 0.04 for VVsep and Lm respectively (S2 Fig).

Discussion

The objective of this research was to develop and validate a semi-automatic counting method for lung morphometry. First, we demonstrated in a series of artificial test images that the use of the macro results in values that closely approach the true geometric characteristics of an image in general. We hypothesize that agreement is not perfect because of a potential sampling error, using a quadratic test system on a quadratic repetition of irregularly placed geometric objects. The use of the “find edges”-function, might also decrease the inner size of the geometric objects by 1 pixel at each edge and explain the slight underestimation of Lm. Both effects are expected to be irrelevant for completely irregular and non-binary lung images.

Second, we showed on lung samples that semi-automatic counting approached the results of manual counting, however R2 was considerably lower than for the artificial test images. In comparison to manual counting it also slightly over- and underestimated VVsep and Lm respectively. Despite manual counting being considered as the gold standard, it is unclear here which methods captures best the true morphometric characteristics of the tissue. A visual check of the mask reveals appropriate segmentation with the semi-automatic method, supporting the accuracy of the semi-automated method. The difference between manual and semi-automatic counting might be explained by a difference in resolution. Semi-automatic counting has a higher resolution, leading to a higher count of Psep and I. The irregularity of the alveolar surface sometimes results in 2 distinct intersections with a 1-pixel thick test line in the plugin, when the human eye in the manual method only sees the alveolar surface touching the test line once. It is plausible that the semi-automated method therefore results in higher accuracy then the manual method, however given the gold standard status of the latter this is impossible to prove.

Third, we also observe a relevant inter-observer variability of the manual results. Semi-automatic counting on the other hand resulted in highly reproducible results. It is theoretically possible that this finding is explained by the macro making a systematic error in estimating the true morphometric characteristics of the tissue, while manual counting results in a random error (hence its high inter-observer variability). We confirm the higher random error if manual data are compared between observers, but also note an important systematic over- or underestimation of Lm (systematic error), which was reduced by the use of the macro. We thus conclude that this macro provides a valid and more reproducible alternative to manual counting that is compatible with a stereological approach.

Additionally, we showed that counting with the macro preserves the manually counted difference in VVsep and Lm between pups raised in hyperoxia (BPD-phenotype) and normoxia (control). Caution should however be taken to use these results as a characterization of the effect of hyperoxia in preterm rabbits. This experiment was not designed for this purpose and the included lungs do not represent a randomized group of pups from the same mothers. We however did previously use this new semi-automatic method to quantify lung structure in several experiments with complete randomization between normoxia and hyperoxia groups [2123]. We anticipate this method can be used for research on BPD in other models, as well as on other diseases that diffusely alter lung structure (e.g. fibrosis or emphysema).

A major advantage of semi-automatic counting is efficiency. The time cost of counting however is, next to the capability of the observer to remain undistracted during this cumbersome and repetitive task, strongly dependent on the amount of inflammatory exudates and non-parenchymal areas on the fields, since these require manual selection. Previously described automatic counting methods did not exclude non-parenchymal areas or did not discriminate between septal tissue and exudates [11, 12, 14]. This can bias the results of these methods. If fields with many vascular structures or alveolar exudates (e.g lungs with important inflammation) are included, Psep and I will probably be overestimated. If these fields are avoided, sampling will be biased towards more peripheral or less diseased areas (less inflammation), while truly random sampling is the cornerstone of a stereological approach. Further improvements in segmentation tools based on machine learning, might lead to a completely automated detection of non-parenchymal tissue or exudates. At the moment however, the human eye remains essential for these tasks.

Because it is of no relevance for the validation of the counting method, we did not focus in this paper on lung processing and sampling. We acknowledge however that it contributes to a great extent to the accuracy of morphometric read-outs in general [7]. Regardless how perfect and fast the counting method, results will be biased if processing is not optimal. Furthermore, the higher the proportion of lung that is sampled (and counted), the more closely the results approach the true structural characteristics of the tissue.

Computerized approaches offer the possibility to increase the sampling density, at a lower time cost, and thereby improve the accuracy of the result. Some authors have developed methods to quantify structural characteristics on a complete lung slide, not requiring sampling of a set of fields [11]. However, the time cost of manually cleaning these whole lung slides from non-parenchymal areas and exudates, outbalances the accuracy gained by a sample density of 100%. Furthermore, it requires specific software and hardware with a high computational speed. Finally, the advances in virtual histology should be noted. Using imaging techniques such as microCT, 3D reconstructions and segmentations have been made on which structural characteristics of pulmonary acini can be measured in 3D, instead of estimated from 2D images [2426].

In conclusion, we developed and validated a semi-automatic method to count alveolar morphometry, compatible with a stereological approach. This semi-automatic method provides highly reproducible results in a relatively fast way. The macro is available for download as a supplement to this paper and runs on open access software (FIJI). We think the use of this method would enhance the quality of the morphometric results in research on BPD, emphysema or fibrosis. Future efforts should go to the development of methods for automatic detection of non-parenchymal areas and exudates and for assessment of structure on 3D reconstructions of lungs scanned with microCT.

Supporting information

S1 Fig

(TIF)

S2 Fig

(TIF)

S1 File. Morphometry_v4.0 plugin.

Plugin for semi-automated morphometry analysis.

(IJM)

S2 File. User manual.

User manual of the morphometry_v4.0 plugin.

(PDF)

S3 File. Checkmorphometry_v4.0 plugin.

Plugin to check the quality of the semi-automated segmentation (optional).

(IJM)

S4 File. Extract_some_tiles_from_tissue_czi_v02 plugin.

Plugin to randomly sample a proportion of a slide scanner image in.czi image in individual.png fields.

(GROOVY)

S5 File. Original data.

Full results used for the analysis presented in the paper.

(XLSX)

Acknowledgments

We acknowledge Katrien Luyten for her technical assistance with lung processing.

Data Availability

All available data is present in the graphs as individual data points. A spreadsheet containing the individual counting results is available in the supplement.

Funding Statement

KA and TS are supported by the SAFEPEDRUG project (funded by the agency for innovation by Science and Technology in Flanders IWT SBO 130033). JT is supported by a C2 grant from KU Leuven (C24/18/101) and a research grant from the Research Foundation – Flanders (FWO G0C4419N). AG is supported by the Erasmus+ Programme of the European Commission (2013–0040). BT is holder of an FWO-SB fellowship (Research Foundation Flanders, 1153220N). YR is holder of an FWO-SB fellowship (Research Foundation - Flanders, 1S71619N). JD is funded by the Great Ormond Street Hospital Charity. The funding bodies had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. www.safepedrug.euwww.ewi-vlaanderen.bewww.fwo.bewww.gosh.orgwww.kuleuven.be/english/research/support/if.

References

  • 1.Schittny JC. Development of the lung. Cell Tissue Res. 2017;367(3):427–44. 10.1007/s00441-016-2545-0 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Herring MJ, Putney LF, Wyatt G, Finkbeiner WE, Hyde DM. Growth of alveoli during postnatal development in humans based on stereological estimation. Am J Physiol Lung Cell Mol Physiol. 2014;307(4):L338–44. 10.1152/ajplung.00094.2014 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Mauderly JL. Effect of age on pulmonary structure and function of immature and adult animals and man. Fed Proc. 1979;38(2):173–7. [PubMed] [Google Scholar]
  • 4.Coalson JJ. Pathology of bronchopulmonary dysplasia. Semin Perinatol. 2006;30(4):179–84. 10.1053/j.semperi.2006.05.004 [DOI] [PubMed] [Google Scholar]
  • 5.Wiebe BM, Laursen H. Lung morphometry by unbiased methods in emphysema: bronchial and blood vessel volume, alveolar surface area and capillary length. Apmis. 1998;106(6):651–6. 10.1111/j.1699-0463.1998.tb01395.x [DOI] [PubMed] [Google Scholar]
  • 6.Knudsen L, Ruppert C, Ochs M. Tissue remodelling in pulmonary fibrosis. Cell Tissue Res. 2017;367(3):607–26. 10.1007/s00441-016-2543-2 [DOI] [PubMed] [Google Scholar]
  • 7.Hsia CC, Hyde DM, Ochs M, Weibel ER. An official research policy statement of the American Thoracic Society/European Respiratory Society: standards for quantitative assessment of lung structure. Am J Respir Crit Care Med. 2010;181(4):394–418. 10.1164/rccm.200809-1522ST [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Muhlfeld C, Hegermann J, Wrede C, Ochs M. A review of recent developments and applications of morphometry/stereology in lung research. Am J Physiol Lung Cell Mol Physiol. 2015;309(6):L526–36. 10.1152/ajplung.00047.2015 [DOI] [PubMed] [Google Scholar]
  • 9.Knudsen L, Weibel ER, Gundersen HJ, Weinstein FV, Ochs M. Assessment of air space size characteristics by intercept (chord) measurement: an accurate and efficient stereological approach. J Appl Physiol (1985). 2010;108(2):412–21. [DOI] [PubMed] [Google Scholar]
  • 10.Tschanz SA, Burri PH, Weibel ER. A simple tool for stereological assessment of digital images: the STEPanizer. J Microsc. 2011;243(1):47–59. 10.1111/j.1365-2818.2010.03481.x [DOI] [PubMed] [Google Scholar]
  • 11.Sallon C, Soulet D, Provost PR, Tremblay Y. Automated High-Performance Analysis of Lung Morphometry. Am J Respir Cell Mol Biol. 2015;53(2):149–58. 10.1165/rcmb.2014-0469MA [DOI] [PubMed] [Google Scholar]
  • 12.Davey MG, Hedrick HL, Bouchard S, Adzick NS, Flake AW, Doolin EJ. Computer-assisted stereology: point fraction of lung parenchyma and alveolar surface density in fetal and newborn sheep. Scanning. 2003;25(1):37–44. 10.1002/sca.4950250108 [DOI] [PubMed] [Google Scholar]
  • 13.Laucho-Contreras ME, Taylor KL, Mahadeva R, Boukedes SS, Owen CA. Automated measurement of pulmonary emphysema and small airway remodeling in cigarette smoke-exposed mice. J Vis Exp. 2015(95):52236 10.3791/52236 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Jacob RE, Carson JP, Gideon KM, Amidan BG, Smith CL, Lee KM. Comparison of two quantitative methods of discerning airspace enlargement in smoke-exposed mice. PLoS One. 2009;4(8):e6670 10.1371/journal.pone.0006670 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Schindelin J, Arganda-Carreras I, Frise E, Kaynig V, Longair M, Pietzsch T, et al. Fiji: an open-source platform for biological-image analysis. Nat Methods. 2012;9(7):676–82. 10.1038/nmeth.2019 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Richter J, Toelen J, Vanoirbeek J, Kakigano A, Dekoninck P, Verbeken E, et al. Functional assessment of hyperoxia-induced lung injury after preterm birth in the rabbit. Am J Physiol Lung Cell Mol Physiol. 2014;306(3):L277–83. 10.1152/ajplung.00315.2013 [DOI] [PubMed] [Google Scholar]
  • 17.Jimenez J, Richter J, Nagatomo T, Salaets T, Quarck R, Wagennar A, et al. Progressive Vascular Functional and Structural Damage in a Bronchopulmonary Dysplasia Model in Preterm Rabbits Exposed to Hyperoxia. Int J Mol Sci. 2016;17(10). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Porzionato A, Guidolin D, Macchi V, Sarasin G, Grisafi D, Tortorella C, et al. Fractal analysis of alveolarization in hyperoxia-induced rat models of bronchopulmonary dysplasia. Am J Physiol Lung Cell Mol Physiol. 2016;310(7):L680–8. 10.1152/ajplung.00231.2015 [DOI] [PubMed] [Google Scholar]
  • 19.Roubliova XI, Deprest JA, Biard JM, Ophalvens L, Gallot D, Jani JC, et al. Morphologic changes and methodological issues in the rabbit experimental model for diaphragmatic hernia. Histol Histopathol. 2010;25(9):1105–16. 10.14670/HH-25.1105 [DOI] [PubMed] [Google Scholar]
  • 20.Koo TK, Li MY. A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research. J Chiropr Med. 2016;15(2):155–63. 10.1016/j.jcm.2016.02.012 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Salaets T, Aertgeerts M, Gie A, Vignero J, de Winter D, Regin Y, et al. Preterm birth impairs postnatal lung development in the neonatal rabbit model. Respir Res. 2020;21(1):59 10.1186/s12931-020-1321-6 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Salaets T, Gie A, Jimenez J, Aertgeerts M, Gheysens O, Vande Velde G, et al. Local pulmonary drug delivery in the preterm rabbit: feasibility and efficacy of daily intratracheal injections. Am J Physiol Lung Cell Mol Physiol. 2019;316(4):L589–l97. 10.1152/ajplung.00255.2018 [DOI] [PubMed] [Google Scholar]
  • 23.Gie A, Salaets T, Vignero J, Regin Y, Vanoirbeek J, Deprest J, et al. Intermittent CPAP limits hyperoxia-induced lung damage in a rabbit model of bronchopulmonary dysplasia. Am J Physiol Lung Cell Mol Physiol. 2020;318(5). [DOI] [PubMed] [Google Scholar]
  • 24.Vasilescu DM, Gao Z, Saha PK, Yin L, Wang G, Haefeli-Bleuer B, et al. Assessment of morphometry of pulmonary acini in mouse lungs by nondestructive imaging using multiscale microcomputed tomography. Proc Natl Acad Sci U S A. 2012;109(42):17105–10. 10.1073/pnas.1215112109 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Kizhakke Puliyakote AS, Vasilescu DM, Newell JD Jr., Wang G, Weibel ER, Hoffman EA. Morphometric differences between central vs. surface acini in A/J mice using high-resolution micro-computed tomography. J Appl Physiol (1985). 2016;121(1):115–22. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Vasilescu DM, Klinge C, Knudsen L, Yin L, Wang G, Weibel ER, et al. Stereological assessment of mouse lung parenchyma via nondestructive, multiscale micro-CT imaging validated by light microscopic histology. J Appl Physiol (1985). 2013;114(6):716–24. [DOI] [PMC free article] [PubMed] [Google Scholar]

Decision Letter 0

Michael Koval

23 Jul 2020

PONE-D-20-17619

A semi-automated method for unbiased alveolar morphometry: validation in a bronchopulmonary dysplasia model

PLOS ONE

Dear Dr. Salaets,

Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process.

Please note that the original Reviewer #2 declined to review the manuscript after initially agreeing to do so.  To avoid further delay, I reviewed the manuscript myself, so I am Reviewer #2.  Along with my critique, I think it is particularly important to demonstrate that the macro can distinguish V-Vsep and Lm values from hyperoxic and normoxic lung sections. A more thorough discussion of how the macro calculated values vary from literature values is warranted. Also, both Reviewer #1 and I would like to see a more detailed analysis and discussion of inter-observer variability in manual morphometric analysis.

Please submit your revised manuscript by Sep 06 2020 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.

Please include the following items when submitting your revised manuscript:

  • A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'.

  • A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.

  • An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'.

If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter.

If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: http://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols

We look forward to receiving your revised manuscript.

Kind regards,

Michael Koval

Academic Editor

PLOS ONE

Journal Requirements:

When submitting your revision, we need you to address these additional requirements.

1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at

https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and

https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf

2. We note that you have included the phrase “data not shown” in your manuscript. Unfortunately, this does not meet our data sharing requirements. PLOS does not permit references to inaccessible data. We require that authors provide all relevant data within the paper, Supporting Information files, or in an acceptable, public repository. Please add a citation to support this phrase or upload the data that corresponds with these findings to a stable repository (such as Figshare or Dryad) and provide and URLs, DOIs, or accession numbers that may be used to access these data. Or, if the data are not a core part of the research being presented in your study, we ask that you remove the phrase that refers to these data.

[Note: HTML markup is below. Please do not edit.]

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

1. Is the manuscript technically sound, and do the data support the conclusions?

The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented.

Reviewer #1: Yes

Reviewer #2: Partly

**********

2. Has the statistical analysis been performed appropriately and rigorously?

Reviewer #1: Yes

Reviewer #2: Yes

**********

3. Have the authors made all data underlying the findings in their manuscript fully available?

The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.

Reviewer #1: Yes

Reviewer #2: Yes

**********

4. Is the manuscript presented in an intelligible fashion and written in standard English?

PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.

Reviewer #1: Yes

Reviewer #2: Yes

**********

5. Review Comments to the Author

Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)

Reviewer #1: This well-written manuscript describes a semi-automated method for determining lung morphometry that meets a critical need in the field of development lung biology and in the study of lung disease. The authors clearly demonstrate the variability between using the more common manual counting methods to determine mean linear intercept and septal thickness. They have made their app available for download in the supplement and provided a user manual that is easy to follow. While this is not the first automated counting method to be described, much of the other software and plugins are proprietary, and this free plug-in works with the ImageJ, which is also freely available to all scientists.

Minor: One issue with the methodology is that manual counting is currently the "gold standard" for validation even though manual counting is not as accurate for all of the reasons described by the authors in their introduction. While the authors do address this issue in the text, perhaps a more detailed discussion on this point would be helpful.

Reviewer #2: In this manuscript the authors present a new semi-automated method for measuring lung morphology. There are several advantages to this method: it is public domain, easy to use and performs well against an artificially generated image. It is also very effective in outlining septal borders (Fig 4). However when applied to actual lung slices, there is a systemic bias in the measurements when compared with manual quantitation. This is especially a concern with mean linear intercept (Lm) which was consistently underestimated when compared with values obtained by manual counting done by three independent observers. The study does not compare calculations between BPD (hyperoxic) and control (normoxic) premature rabbit lungs, either as generated by the authors or with values from the literature. This combined with the systematic overestimation of V-Vsep and underestimation of Lm raises some concerns that need to be addressed.

Specific comments:

1. Lines 135-141: It looks as though there were lung sections from both hyperoxic and normoxic pups yet the data is aggregated so it is difficult to tell whether both types of sections were included in the analysis. It is especially critical to show whether the macro calculates a difference in V-Vsep and Lm between BPD and non-BPD lungs.

2. In reference 16, the authors present Lm values of ~70 (normoxia) and ~95 (hyperoxia) in a comparable BPD rabbit model. How do these compare with the values obtained manually and using the macro in the current study? Can the macro be applied to images from the literature and compared with literature values for V-Vsep and Lm as an added validation method?

3. Although the manual morphometry is presented in the supplement, including a more detailed analysis of systematic bias between the observers in the main body of the manuscript would be interesting. (listed as not shown on line 240)

4. Figure 3d,e. It looks as though the graph in 3d has a bias of -12.1 and 3e has a bias of +6.0. Are these figures reversed?

5. Lines 83-85. "The user has to manually define the threshold between tissue and air only in the first image of a batch (under the critical assumption that all images in a batch are stained in the same batch and acquired with the same microscope settings)." This is a bit confusing. Consider changing to: "The user has to manually define the threshold between tissue and air only in the first image of a batch (under the critical assumption that in each set of tissues are comparably processed, stained and images acquired using the same microscope settings)."

**********

6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.

Reviewer #1: No

Reviewer #2: No

[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.]

While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step.

PLoS One. 2020 Sep 23;15(9):e0239562. doi: 10.1371/journal.pone.0239562.r002

Author response to Decision Letter 0


6 Sep 2020

Rebuttal letter

We thank the editor for considering our manuscript for publication in PlosOne. Below we respond point-by-point (in italics) to the questions raised by the reviewers.

Reviewer #1: This well-written manuscript describes a semi-automated method for determining lung morphometry that meets a critical need in the field of development lung biology and in the study of lung disease. The authors clearly demonstrate the variability between using the more common manual counting methods to determine mean linear intercept and septal thickness. They have made their app available for download in the supplement and provided a user manual that is easy to follow. While this is not the first automated counting method to be described, much of the other software and plugins are proprietary, and this free plug-in works with the ImageJ, which is also freely available to all scientists.

Minor: One issue with the methodology is that manual counting is currently the "gold standard" for validation even though manual counting is not as accurate for all of the reasons described by the authors in their introduction. While the authors do address this issue in the text, perhaps a more detailed discussion on this point would be helpful.

We included a pairwise comparison of manual counting results, to discuss in more detail the problem with manual counting: a random error, but more importantly for Lm also a systematic error.

Reviewer #2: In this manuscript the authors present a new semi-automated method for measuring lung morphology. There are several advantages to this method: it is public domain, easy to use and performs well against an artificially generated image. It is also very effective in outlining septal borders (Fig 4). However when applied to actual lung slices, there is a systemic bias in the measurements when compared with manual quantitation. This is especially a concern with mean linear intercept (Lm) which was consistently underestimated when compared with values obtained by manual counting done by three independent observers. The study does not compare calculations between BPD (hyperoxic) and control (normoxic) premature rabbit lungs, either as generated by the authors or with values from the literature. This combined with the systematic overestimation of V-Vsep and underestimation of Lm raises some concerns that need to be addressed.

Specific comments:

1. Lines 135-141: It looks as though there were lung sections from both hyperoxic and normoxic pups yet the data is aggregated so it is difficult to tell whether both types of sections were included in the analysis. It is especially critical to show whether the macro calculates a difference in V-Vsep and Lm between BPD and non-BPD lungs.

For this validation of methodology we indeed aggregated data from different groups raised in normoxia and hyperoxia. We intended to validate the use of this macro regardless of its value to discriminate normoxia and hyperoxia pups. This discriminative capacity is indeed useful for our research line, but showing that there is a difference between normoxia and hyperoxia does not prove that the macro generates results that are close to the true morphometric characteristics of the lung.

Upon request of the reviewer we added a comparison of normoxia and hyperoxia samples. Of the 17 lungs used for manual to macro comparison, 5 were plain normoxia and 7 were plain hyperoxia. The other 5 pups were in comparable conditions, however received a slightly different experimental treatment. We show that there are comparable differences between the groups whether manual counting or the macro was used to obtain the results. We however think these results should be interpreted with caution. In our therapeutic experiments we always ensure proper randomization of pups from the same mother. For this validation study several samples from different mothers were taken together and no proper randomization has happened between the pups of the included samples.

2. In reference 16, the authors present Lm values of ~70 (normoxia) and ~95 (hyperoxia) in a comparable BPD rabbit model. How do these compare with the values obtained manually and using the macro in the current study? Can the macro be applied to images from the literature and compared with literature values for V-Vsep and Lm as an added validation method?

See answer above.

If one would compare reported values, over time a trend towards less sick animals would be observed. By increasing our experience with the model and improving our care techniques we noticed that animals got less sick. Furthermore the counting method has changed tremendously over years. This manuscript finalizes the many quality improvements we have implemented to our histology workflow. Direct comparison to historical data will therefore be impossible.

Nevertheless we have in the meanwhile published several studies using this algorithm in the model, showing that it can be used to discriminate normoxia, hyperoxia and treated samples (1, 2). Not only Lm or Vvsep but also derived measures have been used.

3. Although the manual morphometry is presented in the supplement, including a more detailed analysis of systematic bias between the observers in the main body of the manuscript would be interesting. (listed as not shown on line 240)

We included a pairwise comparison of manual counting results, to discuss in more detail the problem with manual counting: a large random error, but more importantly for Lm also a systematic error.

4. Figure 3d,e. It looks as though the graph in 3d has a bias of -12.1 and 3e has a bias of +6.0. Are these figures reversed?

We thank the reviewer for remarking this error. After careful revision we also noted some inconsistencies in the calculation of bias (+ or -) in both figures 2 and 3. Figures and the describing text in the result section have been corrected.

5. Lines 83-85. "The user has to manually define the threshold between tissue and air only in the first image of a batch (under the critical assumption that all images in a batch are stained in the same batch and acquired with the same microscope settings)." This is a bit confusing. Consider changing to: "The user has to manually define the threshold between tissue and air only in the first image of a batch (under the critical assumption that in each set of tissues are comparably processed, stained and images acquired using the same microscope settings)."

Has been changed.

1. Salaets T, Aertgeerts M, Gie A, Vignero J, de Winter D, Regin Y, et al. Preterm birth impairs postnatal lung development in the neonatal rabbit model. Respir Res. 2020;21(1):59.

2. Salaets T, Gie A, Jimenez J, Aertgeerts M, Gheysens O, Vande Velde G, et al. Local pulmonary drug delivery in the preterm rabbit: feasibility and efficacy of daily intratracheal injections. Am J Physiol Lung Cell Mol Physiol. 2019;316(4):L589-l97.

Decision Letter 1

Michael Koval

9 Sep 2020

A semi-automated method for unbiased alveolar morphometry: validation in a bronchopulmonary dysplasia model

PONE-D-20-17619R1

Dear Dr. Salaets,

We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements.

Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication.

An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org.

If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org.

Kind regards,

Michael Koval

Academic Editor

PLOS ONE

Acceptance letter

Michael Koval

14 Sep 2020

PONE-D-20-17619R1

A semi-automated method for unbiased alveolar morphometry: validation in a bronchopulmonary dysplasia model

Dear Dr. Salaets:

I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department.

If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org.

If we can help with anything else, please email us at plosone@plos.org.

Thank you for submitting your work to PLOS ONE and supporting open access.

Kind regards,

PLOS ONE Editorial Office Staff

on behalf of

Dr. Michael Koval

Academic Editor

PLOS ONE

Associated Data

    This section collects any data citations, data availability statements, or supplementary materials included in this article.

    Supplementary Materials

    S1 Fig

    (TIF)

    S2 Fig

    (TIF)

    S1 File. Morphometry_v4.0 plugin.

    Plugin for semi-automated morphometry analysis.

    (IJM)

    S2 File. User manual.

    User manual of the morphometry_v4.0 plugin.

    (PDF)

    S3 File. Checkmorphometry_v4.0 plugin.

    Plugin to check the quality of the semi-automated segmentation (optional).

    (IJM)

    S4 File. Extract_some_tiles_from_tissue_czi_v02 plugin.

    Plugin to randomly sample a proportion of a slide scanner image in.czi image in individual.png fields.

    (GROOVY)

    S5 File. Original data.

    Full results used for the analysis presented in the paper.

    (XLSX)

    Data Availability Statement

    All available data is present in the graphs as individual data points. A spreadsheet containing the individual counting results is available in the supplement.


    Articles from PLoS ONE are provided here courtesy of PLOS