Abstract
Background
Epicardial ganglionated plexuses (GP) have an important role in the pathogenesis of atrial fibrillation (AF). The relationship between anatomical, histological and functional effects of GP is not well known. We previously described atrioventricular (AV) dissociating GP (AVD-GP) locations. In this study, we hypothesised that ectopy triggering GP (ET-GP) are upstream triggers of atrial ectopy/AF and have different anatomical distribution to AVD-GP.
Objectives
We mapped and characterised ET-GP to understand their neural mechanism in AF and anatomical distribution in the left atrium (LA).
Methods
26 patients with paroxysmal AF were recruited. All were paced in the LA with an ablation catheter. High frequency stimulation (HFS) was synchronised to each paced stimulus for delivery within the local atrial refractory period. HFS responses were tagged onto CARTO™ 3D LA geometry. All geometries were transformed onto one reference LA shell. A probability distribution atlas of ET-GP was created. This identified high/low ET-GP probability regions.
Results
2302 sites were tested with HFS, identifying 579 (25%) ET-GP. 464 ET-GP were characterised, where 74 (16%) triggered ≥30s AF/AT. Median 97 (IQR 55) sites were tested, identifying 19 (20%) ET-GP per patient. >30% of ET-GP were in the roof, mid-anterior wall, around all PV ostia except in the right inferior PV (RIPV) in the posterior wall.
Conclusion
ET-GP can be identified by endocardial stimulation and their anatomical distribution, in contrast to AVD-GP, would be more likely to be affected by wide antral circumferential ablation. This may contribute to AF ablation outcomes.
Keywords: Ganglionated plexus, Autonomic nervous system, Intrinsic cardiac nerves, Pulmonary vein ectopy, Atrial fibrillation
Highlights
-
•
ET-GP can be stimulated endocardially using high frequency stimulation within the local atrial refractory period.
-
•
ET-GP stimulation displays a wide range of responses from single ectopy to sustained AF and occasionally AV block.
-
•
ET-GP have distinct anatomical regions in patients with AF, and their distribution contrasts that of AV dissociating GP.
-
•
Most ET-GP are in the roof/PV ostia and inadvertently ablated during PVI. This may contribute to AF ablation success.
1. Introduction
Atrial fibrillation (AF) is most commonly caused by rapid electrical discharges from pulmonary veins (PV) (Haïssaguerre et al., 1998). Stimulation of the intrinsic cardiac autonomic nervous system, particularly the atrial ganglionated plexuses (GP) lead to shortening of PV and atrial refractory periods, causing AF (Schauerte et al., 2001). GP are large and dense clusters of nerves in the epicardium of the heart, particularly in the atria (Armour et al., 1997). Clinical studies have used high frequency stimulation (HFS) to functionally identify GP in the endocardium. Commonly, HFS is delivered continuously over several seconds to observe for atrioventricular (AV) dissociation or block, causing significant RR prolongation compared to baseline (Scanavacca et al., 2006; Patterson et al., 2005). We previously mapped the AV dissociating GP (AVD-GP) in the left atrium (LA) of patients with AF, and found that they did not correlate to all topographically studied GP locations (Armour et al., 1997; Kim et al., 2018). AVD-GP were commonly targeted by previous GP ablation studies, which produced mixed results (Scanavacca et al., 2006; Pokushalov et al., 2009; Driessen et al., 2016).
Another method for identifying autonomic sites is to deliver bursts of HFS within the local atrial refractory period (synchronised to paced stimuli; “synchronised HFS”), avoiding direct high-rate myocardial capture like in continuous HFS. Synchronised HFS can reproducibly trigger atrial ectopy and/or AF/AT from sites distant to stimulation (Schauerte et al., 2001; Lim et al., 2011a). We termed these GP as “ectopy triggering GP” (ET-GP) and we noted that these sites did not always produce an AV dissociating effect. However, the initiation of ectopy and AF made these sites appealing targets as upstream triggers for AF. In order to further understand the role of ET-GP in the mechanism in AF, we tested the hypothesis that ET-GP have a different distribution pattern to that which we have previously described.
2. Methods
Patients with symptomatic, paroxysmal AF undergoing first ablation procedure were recruited to the study. We selected patients between 18 and 85 yrs. old, who were suffering from paroxysmal atrial fibrillation, had failed medical therapy and had been referred for ablation therapy. Anyone taking amiodarone was off it for at least 60 days, and off other antiarrhythmics and betablockers for five half-lives before the procedures. The full inclusion and exclusion criteria are in Table 1. Patients gave written informed consent and the study had ethics approval from the Health Research Authority and the Local Research Ethics Committee.
Table 1.
Inclusion criteria | Exclusion criteria |
---|---|
|
|
(NYHA = New York Heart Association).
All patients had general anaesthesia and transthoracic oesophageal echocardiogram (TOE) to rule out left atrial appendage thrombus at the start of their procedures. Transseptal punctures were guided by TOE and fluoroscopy to access the left atrium. The CARTO™ system was used (Biosense Webster, Inc.) for 3D electroanatomical mapping of the left atrium. A decapolar catheter was positioned in the coronary sinus. A 20-pole circumferential catheter (LassoNav, Biosense Webster, Diamond Bar, CA, USA) was used to create a respiratory-gated 3-dimensional electroanatomic map of the LA (CARTO™, Biosense Webster, CA, USA). It was then positioned in the nearest PV to where HFS was being tested in the LA (e.g. left superior PV if HFS tested in the left side of the anterior wall, or left roof). A bipolar 3.5 mm irrigated-tip contact force sensing ablation catheter (Smart-Touch™, Biosense Webster, CA, USA) was used for pacing and delivering HFS. Blood pressure was continuously monitored using a radial arterial line. Heparin was administered throughout the cases to maintain the activated clotting time >300 s.
2.1. Mapping for ET-GP using synchronised HFS
An S88 Grass stimulator (Astro-Med, RI, USA) was used to perform synchronised HFS to map for ET-GP. First, the ablation catheter was positioned at a stable site in the left atrium, aiming >3 g of tissue contact. Also, the left side of the atrium was mapped first, as we often found more ET-GP in these regions. Secondly, the left atrium was paced at a higher rate than the intrinsic rate, using the ablation catheter with high output (10 V) at the distal poles. This checked for consistent atrial capture, no spontaneous atrial ectopy or ventricular capture. Ventricular capture was avoided with high output pacing first, in order to avoid capturing the ventricle with HFS which may cause ventricular arrhythmias. HFS was then synchronised to each pacing stimuli with 80 ms train duration, for up to 15 trains if no ectopy or AF. If atrial ectopy or AF occurred, pacing and HFS were stopped immediately. The same site was re-tested for reproducibility if synchronised HFS triggered ≤3 ectopy. A reproducible atrial ectopy and/or AF/AT triggering response to synchronised HFS was defined as “ET-GP”. If there was no response to HFS, it was deemed a “negative HFS” site. Both ET-GP and negative HFS sites were tagged on the CARTO™ 3D left atrial geometry. If AF was sustained for more than 2 min, direct DC cardioversion was performed up to three times to revert the patient back into sinus rhythm and continue with the synchronised HFS protocol. The LA was globally mapped with HFS, aiming to test at least 80 HFS sites evenly distributed around the LA. Each HFS tested points were within 6 mm distance from each other. HFS was avoided in the left atrial appendage, mitral annulus where there was ventricular capture with pacing, and within the pulmonary veins. All data were recorded at 1000 Hz by the EP recording system (Bard EP, Lowell, MA, USA).
2.2. Ablation protocol
All patients underwent ET-GP ablation with or without pulmonary vein isolation after completing HFS mapping in the LA. These patients underwent 12-month follow-up with multiple Holter monitors as part of another pilot study to assess safety and feasibility of ET-GP ablation. We have not reported the outcomes of the ablation in this paper, as the ablation strategy was heterogenous and the numbers are too small to draw any conclusions on the clinical effect.
2.3. The probability distribution atlas of ET-GP
At the end of procedures, the LA fast anatomical maps of all patients were exported from CARTO™. A representative LA anatomy was chosen as a reference shell and all exported maps were co-registered onto this geometry using a semi-automated process (Ali et al., 2015). Further technical details of this process are described in our AVD-GP mapping study (Kim et al., 2018). A probability of 1 was applied to ET-GP sites and 0 for negative HFS response sites. Only HFS tested sites were included. Each measurement site was weighted by a Gaussian kernel with a variance of 5 mm, which characterised the uncertainty in the measurement of the site location as a result of catheter movement. The probability that an arbitrary test point within the reference atrial surface that has an ET-GP response was then computed per-patient. This was the sum of the product of probabilities of nearby measured sites with their respective weight kernels evaluated at the required point which was then normalised by the sum of the weight kernels evaluated at the point. Resulting maps were then averaged across the patients.
2.4. Statistics
Continuous variables that followed a normal distribution with small measure of spread were expressed as mean and standard deviation (mean ± SD). Continuous variables with skewed distribution and larger measure of spread were expressed as median and interquartile range (IQR).
3. Results
26 patients were recruited. Table 2 shows patient demographics and clinical characteristics. A range of reproducible responses were observed with synchronised HFS, characterised as follows.
Table 2.
Demographic characteristics | |
---|---|
Age (yrs) | 60 ± 9 |
Sex (male) | 18 (69.2%) |
Body mass index (kg/m2) | 27.7 ± 5.3 |
Left ventricular Ejection fraction (%) |
64.5 ± 1.2 |
Left atrial diameter (cm) | 3.69 ± 0.41 |
CHA2DS2-VASc | 1.2 ± 0.9 |
0 | 8 (30.8%) |
1 | 9 (34.6%) |
≥2 | 9 (34.6%) |
Stroke/ Transient ischaemic attack |
1 (3.8%) |
Coronary artery disease | 1 (3.8%) |
Hypertension | 6 (23.1%) |
Diabetes mellitus | 1 (3.8%) |
Continuous variables represented as mean ± SD. Categorical variables represented as numbers (%).
3.1. AV dissociation with synchronised HFS
AV dissociation is the hallmark GP stimulation effect observed with continuous HFS but is also seen occasionally during synchronised HFS. Fig. 1A shows progressive Wenckebach until asystole. Re-testing the same site with continuous HFS produced a more pronounced AV dissociation, confirming the site as AV dissociating GP (AVD-GP). Less frequently, Wenckebach was followed by atrial ectopy and AF with synchronised HFS (Fig. 1B and C), identifying both AVD-GP and ET-GP at a single test site.
3.2. Atrial ectopy and arrhythmia with synchronised HFS
A PV ectopy triggered by synchronised HFS at an ET-GP site was mapped and visualised using CARTOFINDER®. Fig. 1D and Supplementary Video 1 show a step-by-step PV ectopy activation sequence and suggests that atrial ectopy induced by HFS is not the result of direct myocardial capture, but a distant neural effect that occurs remotely to the stimulation site.
Further example of PV ectopy triggered by synchronised HFS is shown in Fig. 2. Similar PV activation sequence is seen in Fig. 2A, B and C after stimulating three different HFS sites in the LA. However, Fig. 2A HFS triggers single PV ectopy only, whereas Fig. 2B and C trigger short run of AF and sustained AF respectively. The mechanism for these varied responses is yet to be determined but illustrates how the neural network can act on a single PV from multiple sites. Also, fewer HFS trains were needed for a more profound myocardial response each time at the same PV end-location. Similar phenomenon was also seen by stimulating the same HFS site and the examples are in the reproducibility section. The range of responses to ET-GP stimulation was seen in most patients and the distribution of this range in a single patient is shown in Supplementary Fig. 1.
We analysed and categorised 464 HFS sites into: <3 beats of atrial ectopy (187 sites, 40%), <30s of atrial arrhythmia (203 sites, 44%), >30s of atrial arrhythmia (74 sites, 16%).
3.3. Reproducibility of atrial ectopy from ET-GP stimulation
Spontaneous ectopy occurs during AF mapping procedures. Therefore, it is important to prove that the observations described in Fig. 1, Fig. 2 are reproducible and are driven by neural stimulation via synchronised HFS, rather than as spontaneous events. All synchronised HFS sites provoking single and short run of ectopy were re-tested from the same location at least twice for reproducibility (Fig. 3A). Sometimes, this triggered non-sustained AF (Fig. 3B). This type of potentiation confirms the reproducibility of neural stimulation even though the effect is more pronounced. Fig. 3C demonstrates an example from a different patient where the same location triggers an almost identical ectopy followed by non-sustained AF on both occasions. These observations confirm that ET-GP sites are anatomically fixed. In total, 150 ET-GP sites were tested at least twice in 26 patients. 118 (79%) retested positive, and 32 (21%) retested negative.
Similarly, negative HFS sites were also reproducible and anatomically fixed (Fig. 3D). We tested a negative site five times and no ectopic responses were elicited. This was repeated in 10 patients to prove that negative sites remain negative.
3.4. Quantification of ET-GP in the LA
A total of 2302 sites were tested with synchronised HFS in the LA, which identified 579 (25%) ET-GP. A median of 97 (IQR 55) HFS sites were tested per patient, which identified a median of 19 (20%; IQR 12) ET-GP per patient. The number of ET-GP ranged widely from one patient to another (Supplementary Fig. 2). There was no direct relationship between the number of HFS tested and the number of ET-GP identified (Supplementary Fig. 3).
3.5. The probability distribution atlas of ET-GP
Registration of all our patients to one reference shell revealed that 58.3% of the total surface area of the LA contained 90% of ET-GP. The average target registration error was 2.78 ± 1.05 mm (where ‘0’ is perfect registration). The probability atlas of ET-GP across the whole LA revealed 30–40% probability of ET-GP in the following anatomical regions: the roof, around the ostia of all PVs except for the base of the right inferior PV in the posterior wall, mid anterior wall, left side of the anterior wall near the right superior PV and left side of the posterior wall near the left inferior PV. Smaller, discrete patches of ≥40% probability of ET-GP was confined to the PV region: left sided PV carina, right superior PV antrum and its ostium in the roof (Fig. 4).
3.6. Comparison of ET-GP and AVD-GP probability distribution
A comparison was made between the ET-GP and the AVD-GP probability distribution atlases (Kim et al., 2018). A clear contrast was seen in the anatomical distribution of the two GP subtypes. This was particularly apparent in the roof, floor and the posterior wall of the LA. This illustrates the complexity of the neural network from a functional perspective.
4. Discussion
The triggered effects of synchronised HFS have been shown to be neurally mediated, and we have provided further evidence with phenomenon observed during synchronised HFS (Schauerte et al., 2001; Lim et al., 2011b; Scherlag et al., 2005). The distribution and characteristics of ET-GP in patients with AF help to explain some of the clinical phenomena described during and after PV isolation (PVI) for AF and support the development of a strategy for autonomic modulation.
4.1. The ganglionated plexuses
GP sites that cause AV-dissociation (AVD-GP) have been frequently cited in clinical studies for AF ablation, with the assumption that it is involved in the arrhythmogenesis of AF. However, PV ectopy is known to trigger AF and this was replicated with synchronised HFS within the local myocardial refractory period at ET-GP (Schauerte et al., 2001; Lim et al., 2011a). HFS within the local myocardial refractory period stimulate the intracardiac nerves without direct myocardial capture. Smaller nerves branch out from the epicardial GP and are located throughout transmural atrial tissue (Cho et al., 2019), and would also stimulate with HFS. A detailed study on the muscle connection and autonomic nerve distribution in the PV-LA junction of the LA showed that both adrenergic and cholinergic nerves were equally spatially distributed along the longitudinal and transmural axes of the PV-LA segments and circumferentially around the PV orifice (Tan et al., 2006). We are likely stimulating both types of nerves with HFS, and this may be the neural composition of ET-GP as we found these to be mostly in the PV-LA junction. Neural stimulation lead to abundant acetylcholine and catecholamine release, which shortens the action potential of the local and adjacent myocardial cells, inducing atrial ectopy and arrhythmia (Patterson et al., 2005; Singh et al., 1999; Chen et al., 2014). The action potential normalises within two beats of HFS cessation (Schauerte et al., 2001).
4.2. The interconnecting neural network of GP
The GP are part of the intricately interconnected autonomic network. The “right lower GP” near the base of the right inferior PV act as an ‘integration centre’ for AV dissociating effects from other GP areas in the atria (Hou et al., 2007). Similarly, stimulation of the GP near the anterior portion of the right superior PV act as the integration centre for slowing of the heart rate and shortening the effective refractory period via the sinoatrial node (Ardell and Randall, 1986; Quan et al., 1999). Ablation at these integration centres abolish their stimulation effects at distant sites (Hou et al., 2007; Malcolme-Lawes et al., 2013).
The current study also demonstrated that ET-GP stimulated at one location in the LA can trigger electrical changes at another without any apparent effect on the myocardium in between the two locations. PVI can transect the neural communication between ET-GP and the isolated PV, and direct ablation over an ET-GP site abolishes its effects of triggering ectopy (Katritsis et al., 2008). The probability atlas from this study shows a preponderance of ET-GP in the PV antra and may explain why circumferential PV antral (CPVA) ablation is superior to segmental isolation, by transecting the GP neural connections into the PVs. This model may explain why 58.6% patients can have of at least one PV re-connected at follow-up mapping without recurrence of AF (Nery et al., 2016). These findings from the ET-GP distribution and behaviour may finally explain some of the inconsistencies from PV isolation simply being about preventing activation exiting the veins.
4.3. Functional and anatomical locations of ET-GP and AVD-GP
We densely mapped the whole LA with synchronised HFS to identify their distinct anatomical sites. The high probability (>30%) sites of ET-GP was consistent with previous anatomical and clinical studies of GP (Haïssaguerre et al., 1998; Hsieh et al., 1999; Lau et al., 1999). Interestingly, there were discrete regions that were absent from ET-GP such as the right side of the posterior wall and the base of the right inferior PV. These regions are likely occupied by AVD-GP, as we described previously (Kim et al., 2018). Similarly, the regions that are absent of AVD-GP are likely occupied by ET-GP. These anatomical differences are important to distinguish to deliver the correct HFS technique to identify all GP.
4.4. Differences in GP responses to HFS
We demonstrated a range of responses with synchronised HFS at an ET-GP site. This may be related to the degree of GP stimulation which can be controlled by the amount of current delivered to the site (Schauerte et al., 2001; Scherlag et al., 2002), which in turn affects the actional potential and atrial effective refractory period shortening. Therefore, a single ectopy-triggering GP site with HFS may be capable of inducing AF with more prolonged HFS or increased current delivery to the GP site (Schauerte et al., 2001).
Occasionally, we observed a progressive Wenckebach with or without ectopy when testing a GP site with synchronised HFS, as previously reported by Lim et al., 2011. Re-testing the site with continuous HFS showed a more pronounced RR prolongation, reaching the threshold for an AVD-GP site. As synchronised HFS can identify both ET-GP and AVD-GP, we would have expected to see more AVD-GP in the posterior wall but found only a few. This may be due to not adequately reaching the threshold for stimulating AVD-GP with shorter bursts of HFS trains used with synchronised HFS.
4.5. Clinical implications
In clinical studies, continuous HFS has been commonly used to identify AVD-GP as targets for autonomic modulation in AF (Driessen et al., 2016; Katritsis et al., 2008). However, continuous HFS does not identify all GP. ET-GP and AVD-GP have very different anatomical and functional characteristics that need to be distinguished to target the relevant GP.
The current standard ablative treatment for AF is complete PVI via CPVA (Kirchhof et al., 2017). CPVA would invariably ablate many ET-GP that are located in the roof and around the PV ostia. This is in effect, both PVI and GP ablation procedure. However, the results from this study demonstrate that there are ET-GP outside the conventional CPVA lines. It is not known whether ET-GP ablation may confer additional benefit to CPVA alone in prevention of AF.
4.6. Limitations
The effect of general anaesthesia on patients' autonomic response to HFS is not known. Co-location of ET-GP and AVD-GP has been identified in some patients, but this has not been consistently tested across all patients as the focus of this paper was in the ET-GP distribution of the LA. Endocardial HFS may not reach to stimulate all GP in the epicardium, and therefore we may be underestimating the quantity of ET-GP in each patient in this study. The morphology of intracardiac electrograms at ET-GP sites were not analysed in this study. It was not possible to prove that synchronised HFS exclusively stimulates the intrinsic nerves or the GP in this clinical study. Further mechanistic studies are warranted to provide evidence for neural activation with synchronised HFS.
5. Conclusion
This study gives further insight into the variation and complexity of the intrinsic cardiac autonomic network in humans. ET-GP stimulation with synchronised HFS displays a wide range of responses from few beats of ectopy to sustained AF, and occasionally AV block with or without atrial arrhythmia. There are distinct high and low probabilities regions of ET-GP in patients with AF, and their anatomical distribution is markedly different to AVD-GP. ET-GP preponderance to the roof and the PV ostia suggest that they are inadvertently ablated during circumferential PVI, which is likely to alter GP function and may contribute to outcomes.
The following are the supplementary data related to this article.
Declaration of competing interest
None.
Acknowledgments
Acknowledgements
This study and some of the authors (BS, FSN, ZW NWFL) were part-funded by British Heart Foundation, UK; British Cardiac Trust, UK funded MYK; Rosetrees Trust, UK part-funded MYK, BHF Centre of Research Excellence, UK part-funded MYK and St Mary's Coronary Flow Trust, UK part-funded MYK. The department is supported by the National Institute for Health Research (NIHR) Biomedical Research Centre based at Imperial College Healthcare NHS Trust and Imperial College London. The views expressed are those of the author(s) and not necessarily those of the NHS, the NIHR or the Department of Health.
Funding
British Cardiac Trust; British Heart Foundation, Grant/Award Number: FS/13/73/30352; St Mary's Coronary Flow Trust, Rosetrees Trust, BHF Centre of Research Excellence.
References
- Ali R.L., Cantwell C.D., Qureshi N.A., Roney C.H., Lim P.B., Sherwin S.J., Siggers J.H., Peters N.S. Proc Annu Int Conf IEEE Eng Med Biol Soc EMBS. 2015. Automated fiducial point selection for reducing registration error in the co-localisation of left atrium electroanatomic and imaging data; pp. 1989–1992. 2015-Novem. [DOI] [PubMed] [Google Scholar]
- Ardell J.L., Randall W.C. Selective vagal innervation of sinoatrial and atrioventricular nodes in canine heart. Am. J. Physiol. Heart Circ. Physiol. 1986;251:H764–H773. doi: 10.1152/ajpheart.1986.251.4.H764. [DOI] [PubMed] [Google Scholar]
- Armour J.A., Murphy D.A., Yuan B.X., Macdonald S., Hopkins D.A. Gross and microscopic anatomy of the human intrinsic cardiac nervous system. Anat. Rec. 1997;247:289–298. doi: 10.1002/(SICI)1097-0185(199702)247:2<289::AID-AR15>3.0.CO;2-L. [DOI] [PubMed] [Google Scholar]
- Chen P.S., Chen L.S., Fishbein M.C., Lin S.F., Nattel S. Role of the autonomic nervous system in atrial fibrillation: pathophysiology and therapy. Circ. Res. 2014;114:1500–1515. doi: 10.1161/CIRCRESAHA.114.303772. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Cho K.H., Kim J.H., Murakami G., Abe H., Rodríguez-Vázquez J.F., Chai O.H. Nerve distribution in myocardium including the atrial and ventricular septa in late stage human fetuses. Anat. Cell Biol. 2019;52:48–56. doi: 10.5115/acb.2019.52.1.48. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Driessen A.H.G., Berger W.R., Krul S.P.J., Berg N.W.E. van den, Neefs J., Piersma F.R., Chan Pin Yin D.R.P.P., Jong J.S.S.G. de, Boven W.P. van, Groot J.R. de. Ganglion plexus ablation in advanced atrial fibrillation. J. Am. Coll. Cardiol. 2016;68:1155–1165. doi: 10.1016/j.jacc.2016.06.036. [DOI] [PubMed] [Google Scholar]
- Haïssaguerre M., Jaïs P., Shah D.C., Takahashi A., Hocini M., Quiniou G., Garrigue S., Mouroux A. Le, Métayer P. Le, Clémenty J. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N. Engl. J. Med. 1998;339:659–666. doi: 10.1056/NEJM199809033391003. [DOI] [PubMed] [Google Scholar]
- Hou Y., Scherlag B.J., Lin J., Zhou J., Song J., Zhang Y., Patterson E., Lazzara R., Jackman W.M., Po S.S. Interactive atrial neural network: determining the connections between ganglionated plexi. Heart Rhythm. 2007;4:56–63. doi: 10.1016/j.hrthm.2006.09.020. [DOI] [PubMed] [Google Scholar]
- Hsieh M.H., Chen S.A., Tai C.T., Tsai C.F., Prakash V.S., Yu W.C., Liu C.C., Ding Y.A., Chang M.S. Double multielectrode mapping catheters facilitate radiofrequency catheter ablation of focal atrial fibrillation originating from pulmonary veins. J. Cardiovasc. Electrophysiol. 1999;10:136–144. doi: 10.1111/j.1540-8167.1999.tb00654.x. [DOI] [PubMed] [Google Scholar]
- Katritsis D., Giazitzoglou E., Sougiannis D., Goumas N., Paxinos G., Camm A.J. Anatomic approach for ganglionic plexi ablation in patients with paroxysmal atrial fibrillation. Am. J. Cardiol. 2008;102:330–334. doi: 10.1016/j.amjcard.2008.03.062. [DOI] [PubMed] [Google Scholar]
- Kim M.Y., Sikkel M.B., Hunter R.J., Haywood G.A., Tomlinson D.R., Tayebjee M.H., Ali R.L., Cantwell C.D., Gonna H., Sandler B.C., Lim E., Furniss G., Panagopoulos D., Begg G., Dhillon G., Hill N.J., O’Neill J., Francis D.P., Lim P.B., Peters N.S., Linton N.W.F., Kanagaratnam P. A novel approach to mapping the atrial ganglionated plexus network by generating a distribution probability atlas. J. Cardiovasc. Electrophysiol. 2018;29:1624–1634. doi: 10.1111/jce.13723. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kirchhof P., Benussi S., Zamorano J.L., Aboyans V., Achenbach S., Agewall S., Badimon L., Barón-Esquivias G., Baumgartner H., Bax J.J., Bueno H., Carerj S., Dean V., Erol Ç., Fitzsimons D., Gaemperli O., Kirchhof P., Kolh P., Lancellotti P., Lip G.Y.H., Nihoyannopoulos P., Piepoli M.F., Ponikowski P., Roffi M., Torbicki A., Carneiro A.V., Windecker S., Hayrapetyan H.G., Roithinger F.X., Aliyev F. 2016 ESC guidelines for the management of atrial fibrillation developed in collaboration with EACTS. Russ. J. Cardiol. 2017;147:7–86. [Google Scholar]
- Lau C.P., Tse H.F., Ayers G.M. Defibrillation-guided radiofrequency ablation of atrial fibrillation secondary to an atrial focus. J. Am. Coll. Cardiol. 1999;33:1217–1226. doi: 10.1016/s0735-1097(98)00691-3. Elsevier Masson SAS. [DOI] [PubMed] [Google Scholar]
- Lim P.B., Malcolme-Lawes L.C., Stuber T., Wright I., Francis D.P., Davies D.W., Peters N.S., Kanagaratnam P. Intrinsic cardiac autonomic stimulation induces pulmonary vein ectopy and triggers atrial fibrillation in humans. J. Cardiovasc. Electrophysiol. 2011;22:638–646. doi: 10.1111/j.1540-8167.2010.01992.x. [DOI] [PubMed] [Google Scholar]
- Lim P.B., Malcolme-Lawes L.C., Stuber T., Kojodjojo P., Wright I.J., Francis D.P., Wyn Davies D., Peters N.S., Kanagaratnam P. Stimulation of the intrinsic cardiac autonomic nervous system results in a gradient of fibrillatory cycle length shortening across the atria during atrial fibrillation in humans. J. Cardiovasc. Electrophysiol. 2011;22:1224–1231. doi: 10.1111/j.1540-8167.2011.02097.x. [DOI] [PubMed] [Google Scholar]
- Malcolme-Lawes L.C., Lim P.B., Wright I., Kojodjojo P., Koa-Wing M., Jamil-Copley S., Dehbi H.M., Francis D.P., Davies D.W., Peters N.S., Kanagaratnam P. Characterization of the left atrial neural network and its impact on autonomic modification procedures. Circ. Arrhythmia Electrophysiol. 2013;6:632–640. doi: 10.1161/CIRCEP.113.000193. [DOI] [PubMed] [Google Scholar]
- Nery P.B., Belliveau D., Nair G.M., Bernick J., Redpath C.J., Szczotka A., Sadek M.M., Green M.S., Wells G., Birnie D.H. Relationship between pulmonary vein reconnection and atrial fibrillation recurrence: a systematic review and meta-analysis. JACC Clin. Electrophysiol. 2016;2:474–483. doi: 10.1016/j.jacep.2016.02.003. [DOI] [PubMed] [Google Scholar]
- Patterson E., Po S.S., Scherlag B.J., Lazzara R. Triggered firing in pulmonary veins initiated by in vitro autonomic nerve stimulation. Heart Rhythm. 2005;2:624–631. doi: 10.1016/j.hrthm.2005.02.012. [DOI] [PubMed] [Google Scholar]
- Pokushalov E., Romanov A., Shugayev P., Artyomenko S., Shirokova N., Turov A., Katritsis D.G. Selective ganglionated plexi ablation for paroxysmal atrial fibrillation. Heart Rhythm. 2009;6:1257–1264. doi: 10.1016/j.hrthm.2009.05.018. Elsevier Inc. [DOI] [PubMed] [Google Scholar]
- Quan K.J., Lee J.H., Geha A.S., Biblo L.A., Van Hare G.F., Mackall J.A., Carlson M.D. Characterization of sinoatrial parasympathetic innervation in humans. J. Cardiovasc. Electrophysiol. 1999;10:1060–1065. doi: 10.1111/j.1540-8167.1999.tb00278.x. [DOI] [PubMed] [Google Scholar]
- Scanavacca M., Pisani C.F., Hachul D., Lara S., Hardy C., Darrieux F., Trombetta I., Negrão C.E., Sosa E. Selective atrial vagal denervation guided by evoked vagal reflex to treat patients with paroxysmal atrial fibrillation. Circulation. 2006;114:876–885. doi: 10.1161/CIRCULATIONAHA.106.633560. [DOI] [PubMed] [Google Scholar]
- Schauerte P., Scherlag B.J., Patterson E., Scherlag M.A., Matsudaria K., Nakagawa H., Lazzara R., Jackman W.M. Focal atrial fibrillation: experimental evidence for a pathophysiologic role of the autonomic nervous system. J. Cardiovasc. Electrophysiol. 2001;12:592–599. doi: 10.1046/j.1540-8167.2001.00592.x. [DOI] [PubMed] [Google Scholar]
- Scherlag B.J., Yamanashi W.S., Schauerte P., Scherlag M., Sun Y.X., Hou Y., Jackman W.M., Lazzara R. Endovascular stimulation within the left pulmonary artery to induce slowing of heart rate and paroxysmal atrial fibrillation. Cardiovasc. Res. 2002;54:470–475. doi: 10.1016/s0008-6363(02)00239-0. [DOI] [PubMed] [Google Scholar]
- Scherlag B.J., Nakagawa H., Jackman W.M., Yamanashi W.S., Patterson E., Po S., Lazzara R. Electrical stimulation to identify neural elements on the heart: their role in atrial fibrillation. J. Interv. Card. Electrophysiol. 2005;13(Suppl. 1):37–42. doi: 10.1007/s10840-005-2492-2. [DOI] [PubMed] [Google Scholar]
- Singh S., Johnson P.I., Javed A., Gray T.S., Lonchyna V.A., Wurster R.D. Monoamine- and histamine-synthesizing enzymes and neurotransmitters within neurons of adult human cardiac ganglia. Circulation. 1999;99:411–419. doi: 10.1161/01.cir.99.3.411. [DOI] [PubMed] [Google Scholar]
- Tan A.Y., Li H., Wachsmann-Hogiu S., Chen L.S., Chen P.S., Fishbein M.C. Autonomic innervation and segmental muscular disconnections at the human pulmonary vein-atrial junction. Implications for catheter ablation of atrial-pulmonary vein junction. J. Am. Coll. Cardiol. 2006;48:132–143. doi: 10.1016/j.jacc.2006.02.054. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.