Skip to main content
Scientific Reports logoLink to Scientific Reports
. 2020 Sep 23;10:15482. doi: 10.1038/s41598-020-72094-4

Facile decoding of quantitative signatures from magnetic nanowire arrays

Mohammad Reza Zamani Kouhpanji 1,2, Ali Ghoreyshi 3, P B Visscher 4, Bethanie J H Stadler 1,
PMCID: PMC7512014  PMID: 32968111

Abstract

Magnetic nanoparticles have been proposed as contact-free minimal-background nanobarcodes, and yet it has been difficult to rapidly and reliably decode them in an assembly. Here, high aspect ratio nanoparticles, or magnetic nanowires (MNWs), are characterized using first-order reversal curves (FORC) to investigate quantitative decoding. We have synthesized four types of nanowires (differing in diameter) that might be used for barcoding, and identified four possible “signature” functions that might be used to quickly distinguish them. To test this, we have measured the signatures of several combination samples containing two or four different MNW types, and fit them to linear combinations of the individual type signatures to determine the volume ratios of the types. We find that the signature which determines the ratios most accurately involves only the slope of each FORC at its reversal field, which requires only 2–4 data points per FORC curve, reducing the measurement time by a factor of 10 to 50 compared to measuring the full FORC.

Subject terms: Magnetic properties and materials, Characterization and analytical techniques

Introduction

Magnetic nanowires (MNWs) are increasingly impacting biomedical applications16, environmental sciences7,8, and quantum devices912. A unique benefit of MNWs is that they can be excited indirectly using an external field, regardless of their surroundings5,1315. Especially in biomedical applications, it is essential to locate, identify, and quantify the targeted MNWs, while using multiple types of MNWs for enriching and multiplexing biological entities4,1517.

MNWs have been characterized by measuring their magnetization at various applied fields using hysteresis loops and/or first-order reversal curves (FORC). Accuracy and speed are competing criteria—hysteresis loop measurements are relatively fast but contain significantly less information than FORC measurements, which typically have 50–100 × more measurement points. For example, hysteresis loops measure saturation magnetization and coercivity, which are sufficient to describe a single type of non-interacting MNW1821. However, hysteresis loops cannot fully describe arrays with multiple types of MNWs, especially if there are interactions between the MNWs2224. FORC, on the other hand, can separate the signals of different types of MNWs but the technique is much slower than hysteresis loops. Theoretical models, such as the mean-field model, have been used to quantify the information in FORC diagrams25,26 by considering perfect arrangements of MNWs with homogeneous properties. These ideal assumptions are not well-satisfied by experimental arrays of MNWs, especially those grown inside polycarbonate templates where the MNW distribution is random.

Historically, FORC measurements have provided qualitative and quantitative descriptions of complex nanomagnetic systems21,2729. Mayergoyz30,31 proposed the current conventional FORC measurement as an identification technique for the classical Preisach model32, which describes magnetic hysteresis loops as a superposition of numerous independent switches, called hysterons, with rectangular hysteresis loops, such as those of isolated MNWs acting like Stoner-Wohlfarth particles33,34. Experimentally, FORC measurements start with applying a large magnetic field Hsat, to ensure the positive saturation of the sample, Fig. 1. The field is then reduced to a predefined field, known as a reversal field, Hr. The moment of the sample is measured while the applied field, H, is slowly increased back to Hsat. This process is repeated with different reversal fields Hr to collect a family of magnetization curves, M(H, Hr), as a function of Hr and H. Mathematically, the FORC distribution is defined31 as

ρ=-122MH,HrHHr 1

The FORC results are typically plotted as heat-maps with axes of coercivity, defined by Hc = (H-Hr)/2, and interaction field, defined by Hu = (H + Hr)/2, see Figures SI-1 and SI-2.

Figure 1.

Figure 1

A schematic FORC measurement with interacting hysterons according to the Preisach model. The inset is a schematic of an individual hysteron, which switches down at the reversal field Hr.

Although the FORC technique is an exceptional method for the qualitative and sometimes quantitative explanation of complex systems3639, it has three main drawbacks. First, FORC usually requires very long measurement times, which is not efficient for biomedical applications or industrial quality control4042. Second, smoothing is required for data processing and can induce spurious features4346. Third, taking two derivatives amplifies noise that can conceal the real features.

It is our objective in this paper to use MNWs as labels or barcodes, which requires that we be able to quickly measure the amounts of each type of MNW in a combined sample. In principle this can be done by fitting the entire FORC distribution to a linear combination of single-type FORC distributions—in fact there is extensive work on this in the rock magnetism literature27. In that case, the components are intimately mixed crystallites of different minerals, so that interactions may invalidate the assumption of linear superposition. Our problem is a bit easier in that each type of MNW is not close to the other types in our combinations, so the pure signatures combine linearly. However, determining the entire FORC distribution is time-consuming. For our purpose, we need a signature that can be measured and fit more quickly, and that is ideally a function of one rather than two variables. Two such distributions are often extracted in FORC analysis: the coercivity distribution (PHc) and interaction field distributions (PHu). These are projections of the FORC heat-maps onto the Hc and Hu axes18,24,35 using the integrals:

PHcHc=-ρHc,HudHuandPHuHu=0ρHc,HudHc 2

We will use these as two of the four “signatures” for rapid characterization of our MNW systems. The last two are also functions of one variable that can be extracted from a FORC experiment (but can also be measured more rapidly): the projection the FORC heat-map onto the Hr axis, which is mathematically equivalent to the irreversible switching field distribution (ISFD), and the backfield remanence magnetization (BRM), both of which will be defined below.

Experimental methods

As a proof of concept, four types of cobalt (Co) magnetic nanowires (MNWs) with average diameters of 32 nm, 55 nm, 110 nm, and 208 nm were prepared using a well-established template-assisted electrodeposition technique20,21 (see SI including Figure SI-3). Each of the four MNW types was measured individually with the FORC technique (magnetic field applied parallel to the MNWs axes), Figure SI-1. Next, several combinations were created with at least two different types of MNWs, and the FORC measurements were repeated, Figure SI-2. For quantitative decoding, the individual magnetic signatures were extracted from each combination FORC measurement using four different signatures: (1) the coercivity distribution (PHc), (2) the interaction field distribution (PHu), (3) irreversible switching field distribution (ISFD), and (4) the backfield remanence magnetization (BRM).

The first and second signatures (PHc and PHu) are calculated using Eq. (2) which project the FORC heat-maps on the Hc and Hu axes, respectively. The third signature is related to the “switching field distribution” (SFD) which is conventionally defined as the derivative of the upper branch of the hysteresis loop [in our notation, M(H, Hr) at H = Hr]:

SFDH=12MH,HH=12MH,HrHrHr=H+12MH,HrHHr=H 3

The term “switching field distribution” is slightly unfortunate because elements “switch” at specific fields only in a system of ideal Preisach hysterons—however, the term is well established so we will use it here. Note that the change in M upon switching is twice the saturation moment—if we define SFD to be the amount of saturation moment switching per unit field, we get the factor of 1/2 shown in Eq. (3). The first term in Eq. (3) vanishes for a reversible system, so we will refer to it as the irreversible SFD (ISFD), and the second term as the reversible SFD. It is schematically shown as the blue line in Fig. 2b. Mathematically, ISFD is also proportional to the projection of the FORC heat-maps onto the Hr axis by integrating over all applied fields:

HrρH,HrdH=-12MH,HrHrH=+12MH,HrHrH=Hr=0+12MH,HrHrH=Hr 4

Note that the first term is zero because the magnetization does not change with Hr at large values of applied field (H) due to saturation.

Figure 2.

Figure 2

Schematic comparison of conventional FORC and alternative methods with necessary data (black dots). The red dashed lines show the direction of the field change. (a) Conventional FORC typically measures ~ 100 data points for each reversal curve, (b) ISFD requires only two data points on each reversal curve (as shown), and (c) BRM measures magnetization at zero field after the application of each Hr.

Finally, the fourth signature (BRM) is the value of magnetization of the sample when the applied field is brought to zero after each application of different Hr values, Fig. 2c.

To determine which of these four magnetic signatures reliably and quantitatively decodes the amounts and types of the MNW in the combinations, we fit the signature of the combination to a linear superposition of the magnetic signatures from individual MNWs types (“volumetric fit” in the figures). For example, for the PHc signature of a combination of MNWs with diameters of 55 nm and 208 nm,

VolumetricfitforPHc=α55nmPHc55nm+α208nmPHc208nm 5

where the volume fraction α55nm = (volume of Co in 55 nm wires)/(total volume of Co) and similarly for α208 nm, so that α55 nm + α208 nm = 1. The RMS error is defined as

RMS=1Ni=1NExp.data-Volumetricfit2 6

where N is the number of data-points for the corresponding signature. The αi coefficients are found by minimizing the RMS. The volume ratio (x) is then

x=α208nmα55nm 7

Each magnetic signature is explained in detail below, and then we explain how the minimum number of points shown in Fig. 2b can be used to obtain the best quantitative signatures with orders of magnitude fewer data points than conventional FORC.

Results

The FORC data and heat-maps were measured and processed using the conventional FORC protocols to obtain signatures for the four Co MNWs samples that contained a single type of MNW (32 nm, 55 nm, 110 nm, and 208 nm), Figure SI-1. Similar conventional FORC measurements and processing were performed for all six combinations of two MNW types and for one combination that included all four MNW types, Figure SI-2.

For quantitative decoding, the FORC heat-maps were first projected on the Hc and Hu axes to find the coercivity distribution (PHc) and interaction distribution (PHu), respectively. The PHc and PHu signatures of individual types of nanowires are shown in parts (a) of Figs. 3 and 4. Combinations of these individual types were then measured (blue lines) and the volume fractions αi were chosen to minimize the RMS error (Eq. 6). Table 1 gives the resulting relative volume fractions.

Figure 3.

Figure 3

Coercivity distribution (PHc, determined by taking an integral over Hu from FORC heat-maps) for (a) normalized for individual types of MNWs, (bg) different combinations of two types of MNWs, as indicated in the legend and (h) one combination of four types. The blue lines show measurements of combinations, and the red lines show the best match for combinations of the individual signatures (from a) using volume ratio, see Table 1.

Figure 4.

Figure 4

Interaction distribution (PHu, the integral over Hc from the FORC heat-maps) for (a) normalized for individual types of MNWs, (bg) different combinations of two types of MNWs, as indicated in the legend and (h) one combination of four types . The blue lines show measurements of combinations, and the red lines show the best match for combinations of the individual signatures (from a) using volume ratio, see Table 1.

Table 1.

Comparison of extracted volume ratios. The ratio x is normalized to the first type listed, i.e., in the first row x = α55 nm/α32 nm.

1:x x from PHc x from PHu x from ISFD x from BRM
Known x Fit Error Fit Error Fit Error Fit Error
Combinations of two
32 nm:55 nm 1.1 0.38 − 0.63 2.6 1.5 0.70 − 0.33 0.47 − 0.56
32 nm:110 nm 5.8 42 6.3 5.1 − 0.11 2.6 − 0.54 21 2.7
32 nm:208 nm 23 880 37 23 − 0.01 20 − 0.13 120 4.0
55 nm:110 nm 5.5 27 3.8 4.5 − 0.18 2.3 − 0.58 12 1.2
55 nm:208 nm 22 440 19 34 0.52 20 − 0.09 98 3.4
110 nm:208 nm 4.0 11 1.8 14 2.5 3.4 − 0.15 3.5 − 0.14
Combination of four
32 nm 1 1 0 0 1 0 1 0
55 nm 1.1 0.95 − 0.14 0.091 − 0.92 1.2 0.12 0.27 − 0.75
110 nm 5.8 26 3.4 0.73 − 0.87 2.8 − 0.52 4.2 − 0.27
208 nm 23 270 11 16 − 0.30 16 − 0.32 11 − 0.53

Of our first two signatures, the projections onto the Hu and Hc axes, PHu is the more effective signature for most combinations with the largest error being 50% overestimation of 208 nm MNWs in a combination with 55 nm MNWs. This may seem like a large error, but many multiplexed nanoparticle diagnoses to date use log scales to plot populations due to large potential offsets5. For example, fluorescence labels have large errors due to background lighting and bleaching4. While this is the case, here we are interested in finding the best magnetic signature for decoding MNWs, so that these signatures are known for comparisons to other labelling systems in future studies.

The first two signatures PHu and PHc require taking two derivatives of the FORC data followed by an integral, but this can be avoided by using the irreversible switching field distribution (ISFD) or backfield remanence magnetization (BRM). Both ISFD and BRM can be obtained directly from the raw data (see Fig. 2). Specifically, ISFD is the change in magnetization at the same applied field when we change the reversal field, Fig. 2b. BRM is the magnetization at zero applied field after applying and removing each Hr, Fig. 2c.

ISFD as a signature can be characterized by two parameters: (I) the amplitude of the local peak associated with each MNW type, proportional to the volume fraction of that type), and (II) the relative location of the peaks (dominated by the coercivity of the MNW type), Fig. 5a. For combined samples, ISFD broadens and forms two local peaks associated with the coercivities of the individual MNWs in each combination where the heights of the peaks indicate the amount of each MNW relative to another.

Figure 5.

Figure 5

Irreversible switching field distribution (ISFD) results, (a) normalized for individual types of MNWs, (bg) different combinations of two types of MNWs, as indicated in the legend and (h) one combination of four types. The blue circles show measurements of combinations, and the red circles show the best match for combinations of the individual signatures (from a) using volume ratio, see Table 1.

It should be emphasized that the sensitivity of ISFD depends on both of the amount, the fraction of irreversible switching, and coercivity of component MNWs, with the latter being the dominant parameter. Therefore, combinations of MNWs can be designed for optimal quantitative decoding by combining high coercivity and low coercivity “signatures”15. For example, in Fig. 5d, the combination contains 22 × more volume of 208 nm-diameter MNWs than 32 nm-diameter MNWs. However, this ratio was easily quantified with high accuracy due to separated peaks in ISFD, third column parameter in Table 1. Combinations of 32 nm or 55 nm MNWs with 110 nm MNWs had the most error (~ 50%) due to the combination of large volume ratios (~ 1:5) and the similarities in coercivity. When the volume ratio was closer (1:1 or 1:4), the coercivities of MNW “barcodes” could be closer without as much impact on decoding the combination. This technique also yielded the best results for decoding all four Co MNW codes from the single 4-way combination, lower section of Table 1.

BRM curves for single MNW types and combinations are shown in Fig. 6. Since the combinations had different magnetic moments, we normalized BRM with respect to their saturation backfield remanence (remanence of the major hysteresis loop, Msbr) to render them from − 1 to + 1. From Fig. 6, it can be seen that the BRM value of any combination is always between the BRM values of the individual MNWs in the combination. Therefore, the BRM shift in the combinations determines the amounts of each MNW present. Two features characterize BRM as a signature4750: (I) the field where it is zero, which is average coercivity of the MNWs, and (II) its overall slope which is correlated to the interaction fields. The fourth parameter in Table 1 has the results of volume ratio calculations. Although this measurement can be very fast compared to PHc and PHu, ISFD appears to be the best signature for these Co MNWs.

Figure 6.

Figure 6

Normalized backfield remanence magnetization (BRM) results for (a) individual types of MNW, (bg) different combinations of two types of MNWs, as indicated in the legend and (h) one combination of four types. The blue circles show measurements of combinations, and the red circles show the best match for combinations of the individual signatures (from a) using volume ratio, see Table 1.

As mentioned in the Experimental Method section, the volume ratio of MNWs present in each combination was calculated using a weighted sum of the individual signatures (parts (a) of the preceding figures) where RMS error between each calculated curve and its respective measured combination curve was minimized. The ratios of these weights, which are the volume of each MNW type, determine to the volume ratios of the MNWs present in each combination. For each of the four magnetic signatures (PHc, PHu, ISFD, and BRM), these volume ratios were tabulated with the known volume ratio for comparison in Table 1. Italic emphasis highlighting was used to show which MNW combinations-signature pairs measured the volume ratio within a factor of 2 (corresponding to + /− 100% error). Most commonly used nanobarcodes, especially in the nanomedicine or biology, use optical nanobarcodes such as fluorescent dyes or quantum dots nanoparticles4,5,13,15,51. These barcode methods typically plot calculated values and errors on log scales, where a factor of 2 is quite small. In this regard, ISFD appears to be an excellent signature for overall decoding MNW combinations. The most effective multiplexing systems, however, will use a combination of techniques. For example, fluorescently-labelled magnetic nanowires could be detected by independent optical and magnetic techniques. Here, we simply report a promising magnetic technique, which has great potential to help future studies of many kinds.

As alluded to above, both ISFD and BRM can also be measured much more quickly than conventional FORC, and involve much simpler and faster data processing. This makes ISFD even more ideal for real-time diagnosis and quality control. Specifically, these signatures do not require massive data processing as required by the conventional FORC analysis4346. For example, conventional FORC analysis typically requires 20–100 curves with 20–100 points each (= 400 to 10,000 points). In contrast, Figs. 2b and 7 show how the ISFD can be calculated from substantially fewer points on each magnetization curve (= 40–200 points). The results in Fig. 5 were calculated using only two points—to test the effect of smoothing, we repeated the analysis using 4 points (as shown in Fig. 7) and similarly with 6 points. The results are given in Figures SI-5 and SI-6, and there was not a notable deviation in ISFD.

Figure 7.

Figure 7

Calculation of smoothed ISFD: The upper (red) FORC begins at Hri and has four measured points (black dots). A straight red line is least-squares fit to these points. The lower FORC begins at Hri+1 and its points are similarly fit to the green line. The black Xs are the points on the two lines with H = Hri, and the vertical distance between them is proportional to the ISFD.

Also, BRM only requires the magnetization at one point, namely zero-field (H = 0) after applying each reversal field (= 20–100 points). It should be emphasized that the BRM measurement is slightly different from the standard remanence measurements, such as isothermal remanence or DC demagnetization remanence, for example50,5255. The BRM protocol saturates combinations before applying and removing each reversal field while the standard remanence protocols measure the remanence after applying and removing a continuous ascending or descending field. Although this signature was not highly effective for the Co MNWs in this study, future magnetic nanoparticles could be engineered to have large BRM differentiation to take advantage of this potentially fast decoding method.

Conclusions

Irreversible switching field distribution (ISFD) was identified as an overall promising signature for decoding MNWs. Both ISFD and BRM can be determined 10–50 × faster than conventional FORC signatures with much simpler data processing. Regardless of the type of MNW, measurement instrument, and the data acquisition system, ISFD and BRM are fast because they require substantially fewer data points. In summary, ISFD has great potential to accelerate decoding, enabling new industry-friendly quality control and real-time diagnosis.

Supplementary information

Supplementary file1 (2.3MB, pdf)

Acknowledgements

This work is based upon work supported primarily by the National Science Foundation under Grant No. CMMI-1762884. Portions of this work were conducted in the Minnesota Nano Center, which is supported by the National Science Foundation through the National Nano Coordinated Infrastructure Network (NNCI) under Award Number ECCS-1542202. Part of this work was performed at the Institute for Rock Magnetism (IRM) at the University of Minnesota. The IRM is a US National Multi-user Facility supported through the Instrumentation and Facilities program of the National Science Foundation, Earth Sciences Division (NSF/EAR 1642268), and by funding from the University of Minnesota.

Author contributions

M.R.Z.K. and B.J.H.S. initiated the original idea and designed the experiments. M.R.Z.K. conducted the samples fabrication, measurements, and processed/analyzed the data. M.R.Z.K., A.G., P.B.V., and B.J.H.S. interpreted the data and contributed to writing/revising the manuscript. B.J.H.S. supervised the study and provided the funding.

Data availability

The datasets collected and/or analyzed during the current study are available from the corresponding author on a reasonable request.

Competing interests

The authors declare no competing interests.

Footnotes

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary information

is available for this paper at 10.1038/s41598-020-72094-4.

References

  • 1.Jeon YS, et al. Metallic Fe–Au barcode nanowires as a simultaneous T cell capturing and cytokine sensing platform for immunoassay at the single-cell level. ACS Appl. Mater. Interfaces. 2019;11:23901–23908. doi: 10.1021/acsami.9b06535. [DOI] [PubMed] [Google Scholar]
  • 2.Martínez-Banderas AI, et al. Iron-based core–shell nanowires for combinatorial drug delivery and photothermal and magnetic therapy. ACS Appl. Mater. Interfaces. 2019;11:43976–43988. doi: 10.1021/acsami.9b17512. [DOI] [PubMed] [Google Scholar]
  • 3.Safronov AP, et al. Polyacrylamide ferrogels with Ni nanowires. Materials (Basel) 2019;12:2582. doi: 10.3390/ma12162582. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Zamani Kouhpanji MR, Um J, Stadler BJH. Demultiplexing of magnetic nanowires with overlapping signatures for tagged biological species. ACS Appl. Nano Mater. 2020;3:3080–3087. doi: 10.1021/acsanm.0c00593. [DOI] [Google Scholar]
  • 5.Zamani Kouhpanji MR, Stadler BJH. A guideline for effectively synthesizing and characterizing magnetic nanoparticles for advancing nanobiotechnology: A review. Sensors. 2020;20:2554. doi: 10.3390/s20092554. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Nemati Z, et al. Magnetic isolation of cancer-derived exosomes using Fe/Au magnetic nanowires. ACS Appl. Nano Mater. 2020;3:2058–2069. doi: 10.1021/acsanm.0c00263. [DOI] [Google Scholar]
  • 7.Moreno JA, et al. Growth of ordered iron oxide nanowires for photo-electrochemical water oxidation. ACS Appl. Energy Mater. 2019;2:8473–8480a. doi: 10.1021/acsaem.9b01343. [DOI] [Google Scholar]
  • 8.Cui H, Shi J, Yuan B, Fu M. Synthesis of porous magnetic ferrite nanowires containing Mn and their application in water treatment. J. Mater. Chem. A. 2013;1:5902–5907. doi: 10.1039/c3ta01692g. [DOI] [Google Scholar]
  • 9.Mohammed H, et al. Controlled spin-torque driven domain wall motion using staggered magnetic wires. Appl. Phys. Lett. 2020;116:032402. doi: 10.1063/1.5135613. [DOI] [Google Scholar]
  • 10.Maqableh MM, et al. Low-resistivity 10 nm diameter magnetic sensors. Nano Lett. 2012;12:4102–4109. doi: 10.1021/nl301610z. [DOI] [PubMed] [Google Scholar]
  • 11.Parkin S, Yang S-H. Memory on the racetrack. Nat. Nanotechnol. 2015;10:195–198. doi: 10.1038/nnano.2015.41. [DOI] [PubMed] [Google Scholar]
  • 12.Um J, et al. Fabrication of long-range ordered aluminum oxide and Fe/Au multilayered nanowires for 3D magnetic memory. IEEE Trans. Magn. 2020;56:1–6. [Google Scholar]
  • 13.Bhana S, Wang Y, Huang X. Nanotechnology for enrichment and detection of circulating tumor cells. Micro Nanosyst. 2015;7:1973–1990. doi: 10.2217/nnm.15.32. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Jeon IT, et al. Magnetic NiFe/Au barcode nanowires with self-powered motion. J. Appl. Phys. 2012;111:5–8. doi: 10.1063/1.3700249. [DOI] [Google Scholar]
  • 15.Zamani Kouhpanji MR, Stadler BJH. Projection method as a probe for multiplexing/demultiplexing of magnetically enriched biological tissues. RSC Adv. 2020;10:13286–13292. doi: 10.1039/D0RA01574A. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Cho JU, et al. Effect of field deposition and pore size on Co/Cu barcode nanowires by electrodeposition. J. Magn. Magn. Mater. 2007;310:2420–2422. doi: 10.1016/j.jmmm.2006.10.809. [DOI] [Google Scholar]
  • 17.Lee JH, et al. Iron-gold barcode nanowires. Angew. Chem. Int. Ed. 2007 doi: 10.1002/anie.200605136. [DOI] [PubMed] [Google Scholar]
  • 18.Zamani Kouhpanji MR, Stadler BJH. Beyond the qualitative description of complex magnetic nanoparticle arrays using FORC measurement. Nano Express. 2020;1:010017. doi: 10.1088/2632-959X/ab844d. [DOI] [Google Scholar]
  • 19.Kouhpanji, M. R. Z. & Stadler, B. J. H. Assessing the reliability and validity ranges of magnetic characterization methods. ArXiv 1–9 (2020).
  • 20.Kouhpanji MRZ, Visscher PB, Stadler BJH. Underlying magnetization responses of magnetic nanoparticles in assemblies. arXiv. 2020;1:1–7. [Google Scholar]
  • 21.Kouhpanji, M. R. Z. & Stadler, B. J. H. Quantitative description of complex magnetic nanoparticle arrays. arXiv:1911.12480 1–9 (2019).
  • 22.Palmero EM, et al. Stepwise magnetization reversal of geometrically tuned in diameter Ni and FeCo bi-segmented nanowire arrays. Nano Res. 2019;12:1547–1553. doi: 10.1007/s12274-019-2385-9. [DOI] [Google Scholar]
  • 23.Fernández JG, Martínez VV, Thomas A, de la Prida Pidal VM, Nielsch K. Two-step magnetization reversal FORC fingerprint of coupled bi-segmented Ni/Co magnetic nanowire arrays. Nanomaterials. 2018;8:1–15. doi: 10.3390/nano8070548. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Ramazani A, Asgari V, Montazer AH, Kashi MA. Tuning magnetic fingerprints of FeNi nanowire arrays by varying length and diameter. Curr. Appl. Phys. 2015;15:819–828. doi: 10.1016/j.cap.2015.04.023. [DOI] [Google Scholar]
  • 25.Gilbert DA, et al. Quantitative decoding of interactions in tunable nanomagnet arrays using first order reversal curves. Sci. Rep. 2014;4:1–5. doi: 10.1038/srep04204. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Dobrotă C-I, Stancu A. Tracking the individual magnetic wires’ switchings in ferromagnetic nanowire arrays using the first-order reversal curves (FORC) diagram method. Phys. B Condens. Matter. 2015;457:280–286. doi: 10.1016/j.physb.2014.10.006. [DOI] [Google Scholar]
  • 27.Carvallo C, Muxworthy AR, Dunlop DJ. First-order reversal curve (FORC) diagrams of magnetic mixtures: Micromagnetic models and measurements. Phys. Earth Planet. Inter. 2006;154:308–322. doi: 10.1016/j.pepi.2005.06.017. [DOI] [Google Scholar]
  • 28.Roberts AP, Heslop D, Zhao X, Pike CR. Understanding fine magnetic particle systems through use of first-order reversal curve diagrams. Rev. Geophys. 2014;52:557–602. doi: 10.1002/2014RG000462. [DOI] [Google Scholar]
  • 29.Dobrotă C-I, Stancu A. What does a first-order reversal curve diagram really mean? A study case: Array of ferromagnetic nanowires. J. Appl. Phys. 2013;113:043928. doi: 10.1063/1.4789613. [DOI] [Google Scholar]
  • 30.Mayergoyz ID. Mathematical models of hysteresis (invited) IEEE Trans. Magn. 1986;22:603–608. doi: 10.1109/TMAG.1986.1064347. [DOI] [Google Scholar]
  • 31.Mayergoyz ID. The classical Preisach model of hysteresis and reversibility. J. Appl. Phys. 1991;69:4602–4604. doi: 10.1063/1.348323. [DOI] [Google Scholar]
  • 32.Preisach F. Uber die magnetische nachwirkung. Mitteilung aus dem Zentrallaboratorium des Wernerwerkes der Siemens Halske. 1935;277:277–302. [Google Scholar]
  • 33.Stancu A, Pike C, Stoleriu L, Postolache P, Cimpoesu D. Micromagnetic and preisach analysis of the first order reversal curves (FORC) diagram. J. Appl. Phys. 2003;93:6620–6622. doi: 10.1063/1.1557656. [DOI] [Google Scholar]
  • 34.Dobrotǎ CI, Stancu A. What does a first-order reversal curve diagram really mean? A study case: Array of ferromagnetic nanowires. J. Appl. Phys. 2013;113:043928. doi: 10.1063/1.4789613. [DOI] [Google Scholar]
  • 35.Valcu BF, Gilbert DA, Liu K, Technology S. Fingerprinting inhomogeneities in recording media using the first-order reversal curve method. IEEE Trans. Magn. 2011;47:2988–2991. doi: 10.1109/TMAG.2011.2146241. [DOI] [Google Scholar]
  • 36.Pike CR, Roberts AP, Verosub KL. Characterizing interactions in fine magnetic particle systems using first order reversal curves. J. Appl. Phys. 1999;85:6660–6667. doi: 10.1063/1.370176. [DOI] [Google Scholar]
  • 37.Frampton MK, et al. First-order reversal curve of the magnetostructural phase transition in FeTe. Phys. Rev. B. 2017;214402:1–8. [Google Scholar]
  • 38.Gilbert DA, et al. Probing the A 1 to L 10 transformation in FeCuPt using the first order reversal curve method. APL Mater. 2014;2:086106. doi: 10.1063/1.4894197. [DOI] [Google Scholar]
  • 39.Ruta S, et al. First order reversal curves and intrinsic parameter determination for magnetic materials; Limitations of hysteron-based approaches in correlated systems. Sci. Rep. 2017;7:1–12. doi: 10.1038/s41598-016-0028-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 40.Gräfe J, Schmidt M, Audehm P, Schütz G, Goering E. Application of magneto-optical Kerr effect to first-order reversal curve measurements. Rev. Sci. Instrum. 2014;85:023901. doi: 10.1063/1.4865135. [DOI] [PubMed] [Google Scholar]
  • 41.De Biasi E. Faster modified protocol for first order reversal curve measurements. J. Magn. Magn. Mater. 2017;439:259–268. doi: 10.1016/j.jmmm.2017.05.005. [DOI] [Google Scholar]
  • 42.Rivas M, Gorria P, Muñoz-Gómez C, Martińez-García JC. Quasi-static AC FORC measurements for soft magnetic materials and their differential interpretation. IEEE Trans. Magn. 2017;53:2–7. doi: 10.1109/TMAG.2017.2696165. [DOI] [Google Scholar]
  • 43.Harrison RJ, Feinberg JM. FORCinel: An improved algorithm for calculating first-order reversal curve distributions using locally weighted regression smoothing. Geochem. Geophys. Geosyst. 2008;9:1–11. doi: 10.1029/2008GC001987. [DOI] [Google Scholar]
  • 44.Cimpoesu D, Dumitru I, Stancu A. DoFORC tool for calculating first-order reversal curve diagrams of noisy scattered data. J. Appl. Phys. 2019;125:023906. doi: 10.1063/1.5066445. [DOI] [Google Scholar]
  • 45.Groß F, et al. gFORC: A graphics processing unit accelerated first-order reversal-curve calculator. J. Appl. Phys. 2019;126:163901. doi: 10.1063/1.5120495. [DOI] [Google Scholar]
  • 46.Berndt TA, Chang L. Waiting for forcot: Accelerating FORC processing 100× using a fast-Fourier-transform algorithm. Geochem. Geophys. Geosyst. 2019;20:6223–6233. doi: 10.1029/2019GC008380. [DOI] [Google Scholar]
  • 47.Martnez Huerta JM, De La Torre Medina J, Piraux L, Encinas A. Self consistent measurement and removal of the dipolar interaction field in magnetic particle assemblies and the determination of their intrinsic switching field distribution. J. Appl. Phys. 2012;111:083914. doi: 10.1063/1.4704397. [DOI] [Google Scholar]
  • 48.Araujo E, Martínez-Huerta JM, Piraux L, Encinas A. Quantification of the interaction field in arrays of magnetic nanowires from the remanence curves. J. Supercond. Nov. Magn. 2018;31:3981–3987. doi: 10.1007/s10948-018-4671-2. [DOI] [Google Scholar]
  • 49.Robertson DJ, France DE. Discrimination of remanence-carrying minerals in mixtures, using isothermal remanent magnetisation acquisition curves. Phys. Earth Planet. Inter. 1994;82:223–234. doi: 10.1016/0031-9201(94)90074-4. [DOI] [Google Scholar]
  • 50.Heslop D, Dillon M. Unmixing magnetic remanence curves without a priori knowledge. Geophys. J. Int. 2007;170:556–566. doi: 10.1111/j.1365-246X.2007.03432.x. [DOI] [Google Scholar]
  • 51.DaCosta MV, Doughan S, Han Y, Krull UJ. Lanthanide upconversion nanoparticles and applications in bioassays and bioimaging: A review. Anal. Chim. Acta. 2014;832:1–33. doi: 10.1016/j.aca.2014.04.030. [DOI] [PubMed] [Google Scholar]
  • 52.De Toro JA, et al. Remanence plots as a probe of spin disorder in magnetic nanoparticles. Chem. Mater. 2017;29:8258–8268. doi: 10.1021/acs.chemmater.7b02522. [DOI] [Google Scholar]
  • 53.Pfeiffer H. Determination of anisotropy field distribution in particle assemblies taking into account thermal fluctuations. Phys. Status Solidi. 1990;118:295–306. doi: 10.1002/pssa.2211180133. [DOI] [Google Scholar]
  • 54.Tsoi G, Wenger L. Investigation of magnetic interactions in large arrays of magnetic nanowires. J. Appl. Phys. 2014 doi: 10.1063/1.2834242. [DOI] [Google Scholar]
  • 55.Elbaile L, Crespo RD, Vega V, García JA. Magnetostatic interaction in Fe–Co nanowires. J. Nanomater. 2012;2012:1–6. doi: 10.1155/2012/198453. [DOI] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary file1 (2.3MB, pdf)

Data Availability Statement

The datasets collected and/or analyzed during the current study are available from the corresponding author on a reasonable request.


Articles from Scientific Reports are provided here courtesy of Nature Publishing Group

RESOURCES