Abstract
One of the primary tools for diagnosing COVID-19 is the nucleic acid-based real-time reverse transcriptase-polymerase chain reaction (RT-PCR) test performed on respiratory specimens. The detection rate of SARS-CoV-2 in lower respiratory specimens (such as sputum) is higher than that for upper respiratory specimens (such as nasal and pharyngeal swabs). However, sputum specimens are usually quite viscous, requiring a homogenization process prior to nucleic acid (NA) extraction for RT-PCR. Sputum specimens from COVID-19 and non-COVID-19 patients were treated with four commonly used reagents—saline, N-acetyl-L-cysteine (NALC), proteinase K (PK), and dithiothreitol (DTT), prior to NA extraction. These reagents were then compared for their performance in diagnosing COVID-19 in real clinical practice. The detection rate of SARS-CoV-2 in PK- or DTT-treated sputum was comparable, and higher than that in sputum treated with NALC or saline. While there was a 4.8% (1/21) false negative rate for the PK- and DTT-treated sputum, neither treatment showed any false positive cases among patients with non-COVID diseases. Moreover, sputum pretreated with saline, NALC, PK or DTT showed higher detection rates of SARS-CoV-2 as compared to pharyngeal swabs. Taken together, we provide direct evidence recommending the use of PK or DTT to pretreat sputum samples to facilitate SARS-CoV-2 detection by clinical laboratories. Moreover, our methods should help to standardize the procedure of processing sputum specimens and improve the ability to detect SARS-CoV-2 in these samples.
Keywords: sputum, detection of SARS-CoV-2, COVID-19, proteinase K (PK), DTT
Coronavirus disease 2019 (COVID-19) outbreak caused by SARS-Cov-2 was declared a global pandemic on Mar 11, 2020. One of the primary tools for diagnosing COVID-19 is the nucleic acid-based, real-time reverse transcriptase-polymerase chain reaction (RT-PCR) test, performed on respiratory specimens. The detection rate of SARS-CoV-2 in lower respiratory specimens (such as sputum) is higher than that obtained with upper respiratory specimens (such as nasal and pharyngeal swabs) (1). However, sputum samples often contain a large amount of mucus and are viscous, resulting in the trap of virus containing cell components within the mucus. This will prevent nuclei acid (NA) extraction reagents from accessing to these components, leading to low yield of RNA. Without being homogenized sufficiently, sputum samples can have multiple adverse effects, such as introducing cross-contamination to the automatic nucleic acid extraction instrument, and causing pipetting errors, clot formation, or failed amplification (2). Surprisingly, a number of kits used for detecting SARS-CoV-2 in sputum lack specific instructions on how to homogenize sputum samples before NA extraction.
Several reagents have been used to homogenize sputum samples, such as proteinase K (PK), dithiothreitol (DTT), and N-acetyl-L-cysteine (NALC). PK is a stable serine alkaline protease, and has broad substrate specificity (2, 3). It is often used to digest abundant proteins present in sputum samples, and preferentially degrades ester and peptide bonds next to the C-termini of hydrophobic, sulfuric, or aromatic amino acids. This digestion process inactivates nucleases that could degrade DNA or RNA during isolation and purification procedures. DTT has a very low redox potential, and is able to quantitatively reduce disulfide bonds and maintain monothiol in a reduced state. As a source of the reactive sulfhydryl groups, NALC is mucolytic (4). It prevents the formation of intramolecular and intermolecular disulfide bonds in sputum samples. By disrupting disulfide bonds, both DTT and NALC are widely used to liquefy mucus (5, 6). The proper homogenization and liquefaction of mucus by PK, DTT, and NALC will help to remove substances that inhibit amplification, as well as increase the yield of extracted RNA. This will ultimately improve the detection of virus RNA by RT-PCR. Using spiked sputum samples, a previous study showed that PK-DNase method was ideal for homogenizing sputum samples prior to RT-PCR for the detection of Middle East respiratory syndrome coronavirus (MERS-CoV) (7). Sputum appeared to be a good clinical specimen in patients at the early stage of SARS infection (8), and it also outperformed nasal/pharyngeal swabs in detecting other respiratory viruses, such as respiratory syncytial virus, parainfluenza virus, and human metapneumovirus (9). More recently, SARS-CoV-2 is shown to be more readily detected in sputum samples than in throat swabs of convalescent COVID-19 patients (10). Despite these findings, clinical assessment is lacking regarding how sputum should be pretreated for its best performance in diagnosing SARS-CoV-2 infections. To address this, we treated clinical sputum specimens with four commonly used reagents—saline, NALC, PK, and DTT, prior to NA extraction, and compared their performance in diagnosing COVID-19 in real practice.
Methods
Sputum Collection
A total of 68 sputum specimens were collected from adult patients admitted to Tongji Hospital, Huazhong University of Science and Technology (Wuhan, China) between Jan 28 and Mar 2, 2020. Of these patients, 21 were diagnosed as SARS-CoV-2 positive (SARS-CoV-2+) based on clinical symptoms (fever, cough, and dyspnea), computed tomography (CT) and/or RT-PCR results from pharyngeal swabs. The remaining 47 patients had diseases unrelated to COVID-19. This study was approved by the ethics committee of Tongji Hospital (TJ-C2030).
Sputum Treatment
All sputum specimens were repeatedly pipetted up and down every 5 min, and vortexed for 30 min. Each sputum specimen was aliquoted into four Eppendorf tubes (500 μl per tube), followed by the addition of 500 μl of saline, NALC (0.5 g/100 ml, Sinopharm Chemical Reagent Co. Ltd, freshly made), PK (1 g/l, TianLong Science and Technology Co., Ltd., Xi'an, China), and DTT (Sputasol, Oxoid Microbiological Products) into each tube. Samples were kept upright at room temperature for 30 min, and pipetted up and down once at the 15 min interval, until completely liquefied.
RNA Extraction and RT-PCR Test
Liquefied sputum samples were centrifuged, and the supernatants (250 μl) were used for RNA extraction on a fully automated nucleic acid extraction system 9600E, using the NA extraction kit from Tianlong Science & Technology (TianLong Science and Technology Co., Ltd., Xi'an, China). The RT-PCR was performed with a SARS-CoV-2 nucleic acid detection kit according to the manufacturer's instructions (Da'an Gene Co., Ltd. of Sun Yat-Sen University, Guangzhou, China, approved by National Medical Products Administration). This kit detects ORF1ab and N genes from SARS-CoV-2. Samples with cycle threshold values (Ct-values) for both genes ≤ 40, or a Ct-value of only one gene ≤ 40, repeated twice, were defined as SARS-CoV-2+. Samples with Ct-values for both genes > 40, or not showing an amplification curve for either gene, were defined as SARS-CoV-2 negative.
Results
With the sputum samples collected from the 47 patients having non-COVID-19 diseases, no amplification curves were observed for either the ORF1ab or N gene under any treatment conditions (saline, NALC, PK, and DTT), suggesting no SARS-CoV-2 in these samples. In contrast, RT-PCR tests of all the sputum samples from the SARS-CoV-2+ patients showed Ct-values for both genes <40, or Ct-values of one gene <40 (repeated twice), under at least one treatment condition. Ct-values of the N gene from saline-, NALC-, PK-, and DTT-pretreated sputum samples were 38.3 ± 9.8, 34.2 ± 8.0, 34.0 ± 7.4, 33.4 ± 6.8, respectively, with the NALC-, PK-, and DTT-pretreated groups significantly lower than the saline-treated group (Figure 1A). Ct-values of the ORF1ab gene from these treatments were 41.4 ± 8.7, 39.3 ± 9.2, 39.3 ± 8.8, 36.9 ± 8.0, respectively, with the DTT-pretreated group significantly different from the saline-treated group (Figure 1B).
According to the positive criteria described in the methods section, pretreatment of sputum samples with NALC, PK, and DTT increased the detection of SARS-CoV-2+ cases to 85.7% (18/21), 95.2% (20/21), and 95.2% (20/21), respectively, as compared to the 52.4% (11/21) obtained with saline pretreated sputum (see Table 1). Of the 8 mucopurulent sputum samples, only 1 was found to be SARS-CoV-2 negative when treated with PK or DTT. Notably, the amount of sputa required for the detection of SARS-CoV-2 by NALC, PK, or DTT treatments was as low as 0.2 ml.
Table 1.
Patient ID | Treatment | Sputum characteristics | ||||||
---|---|---|---|---|---|---|---|---|
Saline | NALC | PK | DTT | Swabs | Viscosity | Appearance | Amount (ml) | |
1 | – | + | + | + | NA | Moderate | Mucopurulent | 2.5 |
2 | – | – | + | + | NA | High | Mucopurulent | 1.6 |
3 | – | + | + | + | – | Moderate | Mucoid | 2 |
4 | – | + | + | + | – | Mild | Mucoid | 1.5 |
5 | – | + | + | + | NA | High | Mucoid | 8 |
6 | + | + | + | + | + | Moderate | Mucopurulent | 6 |
7 | + | + | + | + | + | Mild | Blood-tinged | 1.2 |
8 | + | + | + | + | + | Moderate | Blood-tinged | 1.4 |
9 | + | – | + | + | – | Mild | Mucoid | 0.8 |
10 | – | + | + | + | – | High | Mucopurulent | 0.4 |
11 | – | + | + | + | – | Moderate | Mucoid | 1.5 |
12 | – | + | + | + | NA | Mild | Mucoid | 3 |
13 | + | + | + | + | NA | Mild | Mucoid | 4 |
14 | + | + | + | + | – | High | Mucopurulent | 0.5 |
15 | + | + | + | + | NA | Mild | Mucoid | 16 |
16 | + | + | + | – | – | Moderate | Mucopurulent | 1 |
17 | – | + | + | + | + | High | Mucopurulent | 0.2 |
18 | + | + | + | + | – | High | Mucopurulent | 2.5 |
19 | + | + | + | + | + | Moderate | Blood-tinged | 1.5 |
20 | – | – | – | + | – | Moderate | Mucopurulent | 1.2 |
21 | + | + | + | + | + | High | Blood-tinged | 2 |
A total of 21 sputum specimens were obtained from SARS-CoV-2 positive patients. Saline, NALC, PK, and DTT treatments of sputum were able to detect 52.4% (11/21), 85.7% (18/21), 95.2% (20/21), and 95.2% (20/21) of SARS-CoV-2+ cases, respectively. Pharyngeal swabs were able to detect 40.0% (6/15) of SARS-CoV-2 positive cases. NA, not available.
Of the 21 SARS-CoV-2+ patients, 15 also had pharyngeal swabs collected within 1 day of sputum collection (i.e., when sputum was used for RT-PCR test), with only 40% (6/15) of these patients identified as SARS-CoV-2+ based on testing the swabs by RT-PCR.
Discussion
Based on previous experience with other respiratory viruses, the USA CDC has recommended the use of DTT to pretreat sputum for the detection of SARS-CoV-2. However, there is a lack of direct clinical evidence supporting this suggestion or the use of other chemicals to pretreat sputum prior to performing RT-PCR tests for SARS-CoV-2.
We examined how different pretreatments affected SARS-CoV-2 detection from sputum specimens. Our RT-PCR assay showed a higher sensitivity for detecting the N gene, similar to that reported by others (11, 12). This likely results from the relative amplification differences between the ORF1ab or N genes, as the N gene has a much higher level of subgenomic mRNA (13). The homogenization of sputum by PK and DTT appeared to be very thorough, as these pre-treatments increased the positive rates by ~32.8% as compared to saline-treated sputum. Similar to our report, the detection of human avian influenza A (H7N9) virus from sputum samples is also improved by PK and DTT pretreatment (14). Pretreating sputum samples with NALC also improved the detection of SARS-CoV-2+ cases, with freshly made NALC improving the detection rate by 15% as compared to 1-day-old NALC (data not shown). However, the detection rate of SARS-CoV-2 in NALC-treated sputum was lower than that obtained with PK- or DTT-treated sputum. One plausible reason for this could be that PK and DTT are able to digest mucous protein more completely than NALC, resulting in increased concentration of extracted RNA. Supporting this, DTT (a dithiol having two redox-active cysteine residues) is more effective than NALC (a monothiol) in reducing sputum elasticity (15, 16).
Sputum pretreated with saline, NALC, PK, or DTT showed a higher detection rate than when assessing pharyngeal swabs, a finding similar to that outlined in two recent reports (1, 17). While there was only a 4.8% (1/21) false negative rate for the PK- or DTT-treated sputum samples, neither treatment caused any false positive cases among patients with non-COVID-19 diseases. These data suggest that testing sputum may be a preferred approach to diagnosing COVID-19, as well as differentiating SARS-CoV-2 from other prevalent viral infections that cause similar symptoms (18). Such approaches could potentially decrease the pressure on critical care resources in hospitals where multiple pharyngeal swabs are often required to rule in/out COVID-19. Currently, many point-of-care tests (POCT) have already been developed for SARS-CoV-2 detection. These POCT tests will not only significantly reduce time of testing, but also help to optimize clinical management and increase patient satisfaction (19). While these tests are most likely effective with nasal/pharyngeal swabs or aspirates, it may not work well with non-homogenized sputum. Our findings thus provide a very promising scenario whereby sputum specimens pretreated with PK or DTT, in conjunction with these POCT tests, could significantly increase the accuracy of diagnosing COVID-19 as well as provide rapid diagnosis.
This study was limited to the single collection of sputum from a small number of SARS-CoV-2+ inpatients with moderate to severe infections. Further studies should include more patients, particularly those with mild infections, as well as collect sputum at least twice from each patient. Also, in some cases, there is a limited availability of sputum from COVID-19 patients. In a study with a larger population, ~33% of COVID-19 patients produced sputum (20), and the majority of COVID-19 patients may produce no or very limited amount of sputum. However, since the amount of sputum required for this assay is as low as 0.2 ml, we anticipate that pretreating sputum samples with PK or DTT will facilitate SARS-CoV-2 detection from patients who fail to produce abundant sputum.
Conclusion
In summary, while it is known that sputum samples usually outperform nasal/pharyngeal swabs in detecting respiratory viruses, including SARS-CoV-2, the performance of sputum samples in the diagnosis of COVID-19 can be further affected by the way how sputum was pretreated. We provide direct clinical evidence recommending the use of PK or DTT to pretreat sputum to facilitate SARS-CoV-2 detection in clinical laboratories. This recommendation could be further confirmed with more diverse clinical samples, ultimately improving the procedure of processing sputum specimens for their best performance in detecting SARS-CoV-2.
Data Availability Statement
The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.
Ethics Statement
This study was approved by the ethics committee of Tongji Hospital (TJ-C2030). Written informed consent for participation was not required for this study in accordance with the national legislation and the institutional requirements.
Author Contributions
JP, HY, and ZS had full access to all of the data in the study and take responsibility for the integrity of the data. JP, YL, JS, HY, and ZS: concept and design, acquisition, analysis, or interpretation of data. JP and HY: drafting of the manuscript. BV and KJ: critical revision of the manuscript for important intellectual content. HY: statistical analysis. ZS: obtained funding. HY and ZS: supervision. All authors contributed to the article and approved the submitted version.
Conflict of Interest
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Footnotes
Funding. This work was supported by grants from National Mega Project on Major Infectious Disease Prevention (Grant Nos. 2017ZX10103005-007-001, 2017ZX10103005-007-002). The sponsors had no role in the design and conduct of the study, collection, management, analysis, and interpretation of the data, preparation, review, or approval of the manuscript, and decision to submit the manuscript for publication.
References
- 1.Wang W, Xu Y, Gao R, Lu R, Han K, Wu G, et al. Detection of SARS-CoV-2 in different types of clinical specimens. JAMA. (2020) 323:1843–44. 10.1001/jama.2020.3786 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Wilson D, Yen-Lieberman B, Reischl U, Warshawsky I, Procop GW. Comparison of five methods for extraction of Legionella pneumophila from respiratory specimens. J Clin Microbiol. (2004) 42:5913–6. 10.1128/JCM.42.12.5913-5916.2004 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Sweeney PJ, Walker JM. Proteinase K (EC 3.4.21.14). Methods Mol Biol. (1993) 16:305–11. 10.1385/0-89603-234-5:305 [DOI] [PubMed] [Google Scholar]
- 4.Samuni Y, Goldstein S, Dean OM, Berk M. The chemistry and biological activities of N-acetylcysteine. Biochim Biophys Acta. (2013) 1830:4117–29. 10.1016/j.bbagen.2013.04.016 [DOI] [PubMed] [Google Scholar]
- 5.Cleland WW. Dithiothreitol, a new protective reagent for Sh groups. Biochemistry. (1964) 3:480–2. 10.1021/bi00892a002 [DOI] [PubMed] [Google Scholar]
- 6.Saraswathy Veena V, Sara George P, Jayasree K, Sujathan K. Comparative analysis of cell morphology in sputum samples homogenized with dithiothreitol, N-acetyl-L cysteine, Cytorich®red preservative and in cellblock preparations to enhance the sensitivity of sputum cytology for the diagnosis of lung cancer. Diagn Cytopathol. (2015) 43:551–8. 10.1002/dc.23266 [DOI] [PubMed] [Google Scholar]
- 7.Sung H, Yong D, Ki CS, Kim JS, Seong MW, Lee H, et al. Comparative evaluation of three homogenization methods for isolating Middle East respiratory syndrome coronavirus nucleic acids from sputum samples for real-time reverse transcription PCR. Ann Lab Med. (2016) 36:457–62. 10.3343/alm.2016.36.5.457 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Chan KH, Poon LL, Cheng VC, Guan Y, Hung IF, Kong J, et al. Detection of SARS coronavirus in patients with suspected SARS. Emerg Infect Dis. (2004) 10:294–9. 10.3201/eid1002.030610 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Falsey AR, Formica MA, Walsh EE. Yield of sputum for viral detection by reverse transcriptase PCR in adults hospitalized with respiratory illness. J Clin Microbiol. (2012) 50:21–4. 10.1128/JCM.05841-11 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Han H, Luo Q, Mo F, Long L, Zheng W. SARS-CoV-2 RNA more readily detected in induced sputum than in throat swabs of convalescent COVID-19 patients. Lancet Infect Dis. (2020) 20:655–6. 10.1016/S1473-3099(20)30174-2 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Chu DKW, Pan Y, Cheng SMS, Hui KPY, Krishnan P, Liu Y, et al. Molecular diagnosis of a novel coronavirus (2019-nCoV) causing an outbreak of pneumonia. Clin Chem. (2020) 66:549–55. 10.1093/clinchem/hvaa029 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Lu X, Wang L, Sakthivel SK, Whitaker B, Murray J, Kamili S, et al. US CDC real-time reverse transcription PCR panel for detection of severe acute respiratory syndrome coronavirus 2. Emerg Infect Dis. (2020) 26:1654–65. 10.3201/eid2608.201246 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Moreno JL, Zuniga S, Enjuanes L, Sola I. Identification of a coronavirus transcription enhancer. J Virol. (2008) 82:3882–93. 10.1128/JVI.02622-07 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Yu F, Qiu T, Zeng Y, Wang Y, Zheng S, Chen X, et al. Comparative evaluation of three preprocessing methods for extraction and detection of influenza A virus nucleic acids from sputum. Front Med. (2018) 5:56. 10.3389/fmed.2018.00056 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Rancourt RC, Tai S, King M, Heltshe SL, Penvari C, Accurso FJ, et al. Thioredoxin liquefies and decreases the viscoelasticity of cystic fibrosis sputum. Am J Physiol Lung Cell Mol Physiol. (2004) 286:L931–8. 10.1152/ajplung.00352.2003 [DOI] [PubMed] [Google Scholar]
- 16.Nielsen H, Hvidt S, Sheils CA, Janmey PA. Elastic contributions dominate the viscoelastic properties of sputum from cystic fibrosis patients. Biophys Chem. (2004) 112:193–200. 10.1016/j.bpc.2004.07.019 [DOI] [PubMed] [Google Scholar]
- 17.Lin C, Xiang J, Yan M, Li H, Huang S, Shen C. Comparison of throat swabs and sputum specimens for viral nucleic acid detection in 52 cases of novel coronavirus (SARS-Cov-2)-infected pneumonia (COVID-19). Clin Chem Lab Med. (2020) 58:1089–94. 10.1515/cclm-2020-0187 [DOI] [PubMed] [Google Scholar]
- 18.Cascella M, Rajnik M, Cuomo A, Dulebohn SC, Di Napoli R. Features, Evaluation and Treatment Coronavirus (COVID-19). Treasure Island, FL: StatPearls; (2020). [PubMed] [Google Scholar]
- 19.Sheridan C. Fast, portable tests come online to curb coronavirus pandemic. Nat Biotechnol. (2020) 38:515–8. 10.1038/d41587-020-00010-2 [DOI] [PubMed] [Google Scholar]
- 20.Guan WJ, Ni ZY, Hu Y, Liang WH, Ou CQ, He JX, et al. Clinical characteristics of coronavirus disease 2019 in China. N Engl J Med. (2020) 382:1708–20. 10.1101/2020.02.06.20020974 [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.