Skip to main content
Scientific Reports logoLink to Scientific Reports
. 2020 Oct 7;10:16690. doi: 10.1038/s41598-020-73915-2

Contrast medium administration with a body surface area protocol in step-and-shoot coronary computed tomography angiography with dual-source scanners

Liang Jin 1,#, Yiyi Gao 1,#, Yingli Sun 1, Cheng Li 1, Pan Gao 1, Wei Zhao 1, Ming Li 1,2,
PMCID: PMC7541528  PMID: 33028924

Abstract

We evaluated the feasibility and image quality of prospective electrocardiography (ECG)-triggered coronary computed tomography angiography (CCTA) using a body surface area (BSA) protocol for contrast-medium (CM) administration on both second- and third-generation scanners (Flash and Force CT), without using heart rate control. One-hundred-and-eighty patients with suspected coronary heart disease undergoing CCTA were divided into groups A (BSA protocol for CM on Flash CT), B (body mass index (BMI)-matched patients; BMI protocol for CM on Flash CT), and C (BMI-matched patients; BSA protocol for CM on Force CT). Patient characteristics, quantitative and qualitative measures, and radiation dose were compared between groups A and B, and A and C. Of the 180 patients, 99 were male (median age, 62 years). Average BSA in groups A, B, and C was 1.80 ± 0.17 m2, 1.74 ± 0.16 m2, and 1.64 ± 0.17 m2, respectively, with groups A and C differing significantly (P < 0.001). Contrast volume (50.50 ± 8.57 mL vs. 45.00 ± 6.18 mL) and injection rate (3.90 ± 0.44 mL/s vs. 3.63 ± 0.22 mL/s) differed significantly between groups A and C (P < 0.001). Groups A and C (both: all CT values > 250 HU, average scores > 4) achieved slightly lower diagnostic image quality than group B. The BSA protocol for CM administration was feasible in both Flash and Force CT, and therefore may be valuable in clinical practice.

Subject terms: Radiography, Tomography

Introduction

In 2018, coronary heart disease (CHD) was the leading cause of death in the United States, accounting for 43.8% of deaths overall1. Coronary computed tomography angiography (CCTA) is a noninvasive technique that plays an important role in CHD screening and diagnosis25. The use of iodinated contrast medium (CM) provides sufficient vessel attenuation to allow proper evaluation of blood vessel lesions6,7. However, with the increase in the number of examinations, the use of iodinated CM for CCTA has become a concern, as it may lead to contrast-induced nephropathy (CIN)811, and CM remaining in the right cardiac cavity after the scan is not useful. Although the relationship between CCTA and the development of CIN is under debate, elderly patients with cardiac disease are considered at risk of developing CIN9,12. With the appearance of CT scanners with faster gantry rotation (≤ 350 ms) and wider coverage, scan duration is now shorter, which allows adjustment of the protocol for CM administration9,10,1316.

Most protocols for CM administration are based on body mass index (BMI) or body weight7,8,14,17,18. Some more recent protocols have been based on the patient’s blood volume9 or use a high delivery rate13. However, the enhancement of vessel segments is influenced by the patient’s weight, height (expressed in terms of BMI and body surface area [BSA]), and cardiac output1922.

BSA, an index that is widely used in clinical practice, has been identified as the most promising parameter for adjusting the contrast bolus in future protocols; indeed, an increase in blood volume is well paralleled by BSA21,22. In fact, BSA is considered a better indicator of metabolic mass than body weight, because the former is less affected by abnormal adipose mass21,22. Although there is currently no standard BSA protocol for CM administration, a previous study reported a BSA-adapted scanning protocol in prospective electrocardiography (ECG)-triggered sequence acquisition mode (step-and-shoot) CCTA, with a 64-slice scanner (heart rate < 65 bpm)21. However, the feasibility of using a BSA-based protocol for CM administration without heart rate control on dual-source CT (DSCT) has not been studied. Similarly, it is unknown whether the BSA protocol can produce satisfactory image quality at a lower CM volume and injection rate in DSCT.

Therefore, in this study, we aimed to establish whether using a BSA protocol for CM administration, which involved using less CM, and adjusting the injection rate, was feasible in step-and-shoot CCTA. To this end, we first compared the image quality of the three main coronary arteries visualized with a second-generation DSCT scanner, using a BSA protocol for CM administration in step-and-shoot CCTA, without heart rate control, with that of a BMI protocol. Second, we compared the image quality obtained with this BSA protocol between second-generation and third-generation DSCT scanners.

Materials and methods

Patients

One-hundred-and-eighty patients with suspected coronary heart disease who were scheduled for CCTA examination between January 2018 and January 2019 were enrolled. The 180 patients were divided into three groups: 60 patients underwent step-and-shoot CCTA on a second-generation DSCT scanner, with a BSA protocol for CM administration21 (group A; Table 1); 60 BMI-matched patients underwent step-and-shoot CCTA on a second-generation DSCT scanner with a BMI protocol for CM administration23 (group B, reference group; Table 1); and 60 BMI-matched patients underwent step-and-shoot CCTA on a third-generation DSCT scanner with a BSA protocol for CM administration (group C; Table 1). BSA (m2) was obtained using Stevenson’s formula (BSA [m2] = 0.0061 × height [cm] + 0.0128 × weight [kg] − 0.1529) for Chinese adults24,25

Table 1.

Body surface area (BSA)-adapted and body mass index (BMI)-adapted contrast-medium injection protocol.

BSA BMI
BSA (m2) Contrast volume (mL) Saline volume (mL) Flow rate (mL/s) BMI (kg/m2) Contrast volume (mL) Saline volume (mL) Flow rate (mL/s)
 ≤ 1.70 40 50 3.5  ≤ 20.0 45 50 4
1.70–1.79 45 50 3.5 20.1–24.9 50 45 4
1.80–1.94 55 40 4.0 25.0–29.9 55 40 4
1.95–2.14 60 35 4.5  ≥ 30.0 60 35 5
 > 2.15 70 20 5.0

The exclusion criteria were as follows: (1) patients allergic to iodine contrast agent or with severe renal insufficiency (creatinine ≤ 120 μmol/L); (2) patients with decompensated cardiac insufficiency; (3) patients taking drugs to control heart rate before examination; and (4) patients with arrhythmia, who could not hold their breath, or who had undergone stent implantation or coronary artery bypass grafting.

This prospective study was approved by the ethics committee of Huadong hospital (2019K005) and was carried out in accordance with relevant guidelines and regulations with ‘Discussion and evaluation of optimal use of contrast medium in coronary CT angiography’. All patients signed an informed consent form.

Image acquisition and reconstruction

A second-generation DSCT scanner (Somatom Definition Flash, Siemens Healthcare, Forchheim, Germany) was used in groups A and B, while a third-generation DSCT scanner (Somatom Force, Siemens Healthcare) was used in group C. In all groups, the slice thickness and the interval of image reconstruction were 0.75 mm (see Supplementary Material 1, Tables 1, 2).

Table 2.

Body mass index (BMI)-adapted scanning parameters.

BMI
BMI (kg/m2) Voltage (kV) Current (mA)
 ≤ 20.0 70 CARE dose (4D)
20.1–24.9 80 CARE dose (4D)
25.0–27.4 100 250
27.5–29.9 100 280
 ≥ 30.0 120 300

Quantitative and qualitative evaluation

The CT values and standard deviations (SDs) of coronary arteries were measured and as a qualitative analysis, double-blinded subjective scoring of image quality was performed (see Supplementary Material 2).

Radiation dose

Only the CCTA scanning dose was counted, and the scout view, coronary artery calcium score, and the radiation dose of the automatic bolus-tracking technique were not included. Dose length product (DLP) was automatically determined by the CT scanner. Effective radiation dose (ED) was estimated by multiplying the DLP by a conversion factor of 0.014 mSv/(mGy × cm)13,14.

Statistical analysis

IBM SPSS Statistics 22 (IBM, Chicago, IL, USA) software was used for statistical analysis. Levene’s test was used to assess normality of distribution of continuous variables. Continuous variables were expressed as means ± SD. Differences in patient characteristics, radiation dose, and quantitative and qualitative measures between groups A and B as well as between groups A and C were tested for significance with the independent-samples t-test. A two-tailed P-value (P) < 0.05 was considered to be statistically significant. Kappa analysis was used to evaluate interobserver agreement. The kappa value was defined as follows: < 0.20, poor agreement; 0.21–0.40, slight agreement; 0.41–0.60, moderate agreement; 0.61–0.80, good agreement; and 0.81–1.00, almost perfect agreement26.

Results

CCTA was successfully performed in all 180 patients (99 [55%] men and 81 [45%] women; median age, 62 years). The patient characteristics and radiation doses are shown in Table 3.

Table 3.

Patient characteristics and radiation dose comparison.

Parameters Group A (N = 60) Group B (N = 60) P value Group A (N = 60) Group C (N = 60) P value
BSA (m2) 1.80 ± 0.17 1.74 ± 0.16 0.061 1.80 ± 0.17 1.64 ± 0.17 0.0001
BMI (kg/m2) 24.75 ± 2.57 23.96 ± 2.35 0.083 24.75 ± 2.57 24.10 ± 2.68 0.184
CM (mL) 50.50 ± 8.57 51.00 ± 2.02 0.662 50.50 ± 8.57 45.00 ± 6.18 0.0001
FL (mL/s) 3.90 ± 0.44 4.00 ± 0.00 0.083 3.90 ± 0.44 3.63 ± 0.22 0.0001
DLP 190.39 ± 97.21 184.88 ± 64.20 0.715 190.39 ± 97.21 196.57 ± 51.91 0.665
ED (mSv) 2.66 ± 1.36 2.59 ± 0.89 0.715 2.66 ± 1.36 2.75 ± 0.73 0.665
HR (bpm) 64.88 ± 11.03 (39–94) 64.67 ± 13.17 (41–90) 0.924 64.88 ± 11.03 (39–94) 61.70 ± 12.19 (65–90) 0.137

BMI, body mass index; BSA, body surface area; CM, contrast medium; DLP, dose length product; ED, effective radiation dose; FL, flow rate; HR, heart rate.

Quantitative and qualitative evaluation

Table 4 shows a comparison of the measured CT values and subjective image quality scores (see Supplementary Material 3, Fig. 1). Representative images obtained with the Flash and Force CT scanners are shown in Figs. 2 and 3, respectively.

Table 4.

Comparison of quantitative and qualitative analysis results.

Parameters Group A (N = 60) Group B (N = 60) P value Group A (N = 60) Group C (N = 60) P value
AO (HU) 469.80 ± 97.69 566.78 ± 102.23 0.0001 469.80 ± 97.69 505.63 ± 111.56 0.064
LAD-P (HU) 474.23 ± 108.96 578.22 ± 97.30 0.0001 474.23 ± 108.96 476.17 ± 113.35 0.925
LAD-D (HU) 300.19 ± 76.61 332.53 ± 113.07 0.070 300.19 ± 76.61 256.18 ± 68.75 0.0001
LCX-P (HU) 474.23 ± 108.96 578.22 ± 97.30 0.0001 474.23 ± 108.96 476.17 ± 113.35 0.925
LCX-D (HU) 344.08 ± 108.00 379.08 ± 93.99 0.061 344.08 ± 108.00 283.48 ± 74.33 0.001
RCA-P (HU) 469.12 ± 93.98 545.12 ± 91.12 0.0001 469.12 ± 93.98 485.95 ± 192.32 0.544
RCA-D (HU) 415.35 ± 100.27 473.24 ± 110.85 0.003 415.35 ± 100.27 469.86 ± 142.09 0.017
AO_CNR 14.83 ± 22.69 11.60 ± 6.87 0.293 14.83 ± 22.69 8.87 ± 5.62 0.052
LAD-P_CNR 39.51 ± 16.88 51.56 ± 30.59 0.009 39.51 ± 16.88 35.32 ± 18.50 0.198
LCX-P_CNR 39.51 ± 16.88 51.56 ± 30.59 0.009 39.51 ± 16.88 35.32 ± 18.50 0.198
RCA-P_CNR 39.42 ± 17.35 47.78 ± 26.85 0.045 474.23 ± 108.96 34.89 ± 17.31 0.155
Qualitative analysis for RCA 4.62 ± 0.53 (3.5–5) 4.72 ± 0.36 (4–5) 0.231 4.62 ± 0.53 (3.5–5) 4.83 ± 0.33 (4–5) 0.011
Qualitative analysis for LAD 4.16 ± 0.56 (3–5) 4.40 ± 0.39 (3.5–5) 0.016 4.16 ± 0.56 (3–5) 4.40 ± 0.34 (4–5) 0.012
Qualitative analysis for LCX 4.17 ± 0.60 (3–5) 4.25 ± 0.53 (3–5) 0.423 4.17 ± 0.60 (3–5) 4.15 ± 0.32 (3.5–5) 0.850

AO, aortic root; HU, Hounsfield units; LAD-D, distal left anterior descending; LAD-P, proximal left anterior descending; LCX-D, distal left circumflex; LCX-P, proximal left circumflex; PVAT, perivascular adipose tissue; RCA-D, distal proximal right coronary artery; RCA-P, proximal right coronary artery.

Figure 1.

Figure 1

Comparison of CT values of all measurements in all groups. (A) Comparison of groups A and B. (B) Comparison of groups A and C.

Figure 2.

Figure 2

Representative image of a 70-year-old female patient, body surface area (BSA) 1.58 m2, body mass index (BMI) 27.27 kg/m2, heart rate (HR) 96 bpm, obtained using 40 mL contrast agent injected at a flow rate of 3.5 mL/s on a Flash computed tomography scanner.

Figure 3.

Figure 3

Representative image of a 59-year-old female patient, body surface area (BSA) 1.48 m2, body mass index (BMI) 23.8 kg/m2, heart rate (HR) 85 bpm, using 40 mL of contrast agent injected at a flow rate of 3.5 mL/s on a Force computed tomography scanner.

Discussion

In this study, we compared the feasibility of using a BSA protocol for CM administration in step-and-shoot CCTA on Flash and Force CT; implementation of the protocol was feasible, and the image quality obtained on both second- and third-generation CT scanners was satisfactory for diagnosis.

Pazhenkottil et al. demonstrated that a CM-injection protocol based on BSA was feasible with a 64-slice CT scanner, using a step-and-shoot acquisition mode, in 201021. However, in daily practice, we found that the BSA-adapted scanning protocol was not suitable for use in DSCT with free heart rate, as some CM remained in the right heart chambers after the scan. CIN is closely related to existing renal insufficiency and the use of a large amount of CM27,28.

With both scanners used in this study, the scan duration is shorter, reducing the amount of CM required. The Flash CT scanner is a 64-slice scanner with two X-ray tubes, while the Force CT scanner has an additional wider-coverage detector (5.76 cm, 96-slice)29,30. Hence, in this study, we designed a new BSA protocol for Chinese adults in which the maximum contrast volume was reduced to 90 mL, corresponding to a maximum injection rate of 5 mL/s to keep the injection duration similar (approximately 13 s) for a BSA of 1.7–2.14 m2, with a reduction of 20 mL of contrast volume for large BSAs (> 2.15 m2).

A recent study used a first-generation DSCT scanner with a double low-dose strategy and a high iodine delivery rate (IDR) of more than 2.0 g iodine/s in terms of the total iodine dose (TID)13, and achieved a TID of 19.5 ± 2.7 g iodine (gI) with an IDR of 2.22 gI/s. In our study, we achieved a TID of 18.69 ± 3.17 gI with an IDR of 1.44 ± 0.16 gI/s in group A. Our values were reduced (TID: 4%; IDR: 35%) without a decrease in diagnostic image quality. The BMI, BSA, and iodine concentration of group A were similar to those of group 2 in the previous study13. In the present study, group A had an average volume of 50.50 ± 8.57 mL (range, 40–70 mL) and average BSA of 1.80 ± 0.17 m2 (approximate TID per m2, 10.23 gI/m2) while group C had an average volume of 45.00 ± 6.18 mL (range, 40–55 mL) and average BSA of 1.64 ± 0.17 m2 (approximately 10.15 gI/m2). This corresponded to a reduction of 19% and 20.5% in TID/m2, respectively, as compared with the 70.9 ± 14.1 mL for 1.98 m2 (approximately 12.77 gI/m2) in a study by Pazhenkottil et al21.

In quantitative and qualitative analysis of Flash CT images, group A showed an average CT value of more than 300 HU in all measured segments. Although vessel enhancement was slightly lower than that in group B (the reference group), and the average qualitative scores in group B were better than those in group A, the image quality was not affected, as the optimal images had high intra-arterial opacification of more than 250 HU11. Moreover, all qualitative scores exceeded 4. The BSAs of groups A and C were significantly different (P < 0.001), which resulted in significant differences in both contrast volume and injection rate (P < 0.001). Nevertheless, the image quality met diagnostic demands, with subjective scores > 4. Furthermore, vessel enhancement in the AO and proximal coronary arteries was greater than 400 HU, and even the lower levels of enhancement in the distal coronary arteries exceeded 250 HU.

Heart rate is one of the main factors affecting the quality of coronary imaging3135, determining the acquisition mode of CCTA. Previous studies have suggested that high-pitch scanning was helpful to reduce the contrast-medium volume and injection rate10,17,36, due to the very short scan duration (< 1 s). However, high-pitch scanning is strictly limited by heart rate. Gordic et al. proved that the diagnostic rate in cases with a heart rate > 75 bpm on Force CT was only 14%. In fact, using a high-pitch mode on Flash CT requires that the heart rate did not exceed 63 bpm; this requirement was relaxed to 70 bpm on Force CT29. Step-and-shoot acquisition has advantages over high-pitch scanning, due to the more relaxed heart rate limits9,16,22. as well as over retrospective ECG-gated scanning, due to its lower radiation dose3739]. However, it involves a longer acquisition time for a higher injection rate to maintain sufficient peak intravascular enhancement. In this study, heart rate ranged from 39 bpm to 94 bmp. Higher heart rates were mainly supported by the fast gantry rotation of DSCT, and the temporal resolution was increased from 83 to 75 ms for the Flash CT and to 66 ms for the Force CT. A previous study reported decreased coronary arterial attenuation with an increased heart rate during DSCT-CCTA, without heart rate control during data acquisition6. Our findings demonstrated the feasibility of using a BSA-based protocol with a lower contrast-medium volume and a slower injection rate at higher heart rates. This was consistent with the findings of a previous study21 that showed that lower injection rates (< 5 mL/s) were sufficient for coronary artery enhancement in step-and-shoot acquisition (when the heart rate < 65 bpm).

The present study had some limitations. First, the study covered relatively narrow BMI and BSA ranges. Therefore, assuming potential differences in body composition extremes, it may not be possible to generalize or extrapolate our findings to other populations. Second, further improvement in terms of even lower CM volume and slower injection rate is possible, because CM was still found in the right atrium after scanning in some patients, which could decrease image quality. Third, coronary angiography was not considered as the gold standard. Fourth, although the BSA of group C was not matched, it was still challenging to obtain sufficient enhancement in vessel segments with the lower contrast volume and slower injection rate in cases with higher heart rates and the image quality in group C was also satisfied. Therefore, the image quality could not be compared between groups. Nevertheless, the image quality still indicated the feasibility of using the BSA protocol on Force CT.

Conclusion

Using the BSA protocol for CM administration, we could achieve better diagnostic image quality in step-and-shoot CCTA with free heart rate than with the BMI protocol, on both Flash and Force CT scanners. Thus, we demonstrated that using the BSA protocol for CM administration was feasible in step-and-shoot CCTA.

Supplementary information

Acknowledgments

No applicable.

Abbreviations

AO

Aortic root

BMI

Body mass index

BSA

Body surface area

CCTA

Coronary computed tomography angiography

CHD

Coronary heart disease

CIN

Contrast-induced nephropathy

CM

Contrast-medium

CT

Computed tomography

DSCT

Dual-source computed tomography

ECG

Electrocardiography

LAD-D

Distal left anterior descending

LAD-P

Proximal left anterior descending

LCX-D

Distal left circumflex

LCX-P

Proximal left circumflex

PVAT

Perivascular adipose tissue

RCA-D

Distal proximal right coronary artery

RCA-P

Proximal right coronary artery

Author contributions

L.J. and Y.G. wrote the main manuscript text, Y.S., C.L. and P.G. prepared figures, W.Z. edited the main manuscript text and M.L. was the supervisor of this study.

Funding

This work was supported by the National Key Research and Development Program of China 2017YFC0112800 (P.W.) and 2017YFC0112905 (J.S.); the Medical Imaging Key Program of Wise Information Technology of 120, Health Commission of Shanghai 2018ZHYL0103 (M.L.); and Youth Medical Talents –Medical Imaging Practitioner Program (AB83030002019004,L.J.). The funding sources played no role in the study design; collection, analysis, and interpretation of data; writing of the report; or decision to submit the article for publication.

Competing interests

The authors declare no competing interest.

Footnotes

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

These authors contributed equally: Liang Jin and Yiyi Gao.

Supplementary information

is available for this paper at 10.1038/s41598-020-73915-2.

References

  • 1.Benjamin EJ, Muntner P, Alonso A, et al. Heart disease and stroke statistics-2019 update: A report from the American Heart Association. Circulation. 2019;139:e56–e528. doi: 10.1161/CIR.0000000000000659. [DOI] [PubMed] [Google Scholar]
  • 2.Miller JM, Rochitte CE, Dewey M, et al. Diagnostic performance of coronary angiography by 64-row CT. N. Engl. J. Med. 2008;359:2324–3233. doi: 10.1056/NEJMoa0806576. [DOI] [PubMed] [Google Scholar]
  • 3.Neefjes LA, Rossi A, Genders TS, et al. Diagnostic accuracy of 128-slice dual-source CT coronary angiography: A randomized comparison of different acquisition protocols. Eur. Radiol. 2013;23:614–622. doi: 10.1007/s00330-012-2663-3. [DOI] [PubMed] [Google Scholar]
  • 4.Moscariello A, Vliegenthart R, Schoepf UJ, et al. Coronary CT angiography versus conventional cardiac angiography for therapeutic decision making in patients with high likelihood of coronary artery disease. Radiology. 2012;2265:385–392. doi: 10.1148/radiol.12112426. [DOI] [PubMed] [Google Scholar]
  • 5.Litt HI, Gatsonis C, Snyder B, et al. CT angiography for safe discharge of patients with possible acute coronary syndromes. N. Engl. J. Med. 2012;366:1393–1403. doi: 10.1056/NEJMoa1201163. [DOI] [PubMed] [Google Scholar]
  • 6.Zhu X, Chen W, Li M, et al. Contrast material injection protocol with the flow rate adjusted to the heart rate for dual source CT coronary angiography. Int. J. Cardiovasc. Imaging. 2012;28:1557–1565. doi: 10.1007/s10554-011-9950-y. [DOI] [PubMed] [Google Scholar]
  • 7.Qu TT, Li JY, Jiao XJ, et al. Contrast dose reduction with shortened injection durations in coronary CT angiography on 16-cm wide-detector CT scanner. Br. J. Radiol. 2018;91:20180580. doi: 10.1259/bjr.20180580. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Mihl C, Kok M, Altintas S, et al. Evaluation of individually body weight adapted contrast media injection in coronary CT-angiography. Eur. J. Radiol. 2016;85:830–836. doi: 10.1016/j.ejrad.2015.12.031. [DOI] [PubMed] [Google Scholar]
  • 9.Eijsvoogel NG, Hendriks B, Willigers JL, et al. Personalization of injection protocols to the individual patient's blood volume and automated tube voltage selection (ATVS) in coronary CTA. PLoS ONE. 2018;13:e203682. doi: 10.1371/journal.pone.0203682. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Feng R, Tong J, Liu X, Zhao Y, Zhang L. High-pitch coronary CT angiography at 70 kVp adopting a protocol of low injection speed and low volume of contrast medium. Korean J. Radiol. 2017;18:763–772. doi: 10.3348/kjr.2017.18.5.763. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Abbara S, Blanke P, Maroules CD, et al. SCCT guidelines for the performance and acquisition of coronary computed tomographic angiography: A report of the society of Cardiovascular Computed Tomography Guidelines Committee: Endorsed by the North American Society for Cardiovascular Imaging (NASCI) J. Cardiovasc. Comput. Tomogr. 2016;10:435–449. doi: 10.1016/j.jcct.2016.10.002. [DOI] [PubMed] [Google Scholar]
  • 12.Aycock RD, Westafer LM, Boxen JL, Majlesi N, Schoenfeld EM, Bannuru RR. Acute kidney injury after computed tomography: A meta-analysis. Ann. Emerg. Med. 2018;71:44–53. doi: 10.1016/j.annemergmed.2017.06.041. [DOI] [PubMed] [Google Scholar]
  • 13.Tan SK, Ng KH, Yeong CH, et al. Personalized administration of contrast medium with high delivery rate in low tube voltage coronary computed tomography angiography. Quant. Imaging Med. Surg. 2019;9:552–564. doi: 10.21037/qims.2019.03.13. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Chen Y, Wang Q, Li J, Jia Y, Yang Q, He T. Triple-rule-out CT angiography using two axial scans with 16 cm wide-detector for radiation dose reduction. Eur. Radiol. 2018;28:4654–4661. doi: 10.1007/s00330-018-5426-y. [DOI] [PubMed] [Google Scholar]
  • 15.Kok M, Mihl C, Hendriks BM, et al. Optimizing contrast media application in coronary CT angiography at lower tube voltage: Evaluation in a circulation phantom and sixty patients. Eur. J. Radiol. 2016;85:1068–1074. doi: 10.1016/j.ejrad.2016.03.022. [DOI] [PubMed] [Google Scholar]
  • 16.Albrecht MH, Nance JW, Schoepf UJ, et al. Diagnostic accuracy of low and high tube voltage coronary CT angiography using an X-ray tube potential-tailored contrast medium injection protocol. Eur. Radiol. 2018;28:2134–2142. doi: 10.1007/s00330-017-5150-z. [DOI] [PubMed] [Google Scholar]
  • 17.Liu J, Gao J, Wu R, Zhang Y, Hu L, Hou P. Optimizing contrast medium injection protocol individually with body weight for high-pitch prospective ECG-triggering coronary CT angiography. Int. J. Cardiovasc. Imaging. 2013;29:1115–1120. doi: 10.1007/s10554-012-0170-x. [DOI] [PubMed] [Google Scholar]
  • 18.Tang Z. Application of double low dose combined low flow injection in coronary dual-source coronary computed tomography angiography. Echocardiography. 2018;35:1442–1447. doi: 10.1111/echo.14036. [DOI] [PubMed] [Google Scholar]
  • 19.Husmann L, Alkadhi H, Boehm T, et al. Influence of cardiac hemodynamic parameters on coronary artery opacification with 64-slice computed tomography. Eur. Radiol. 2006;16:1111–1116. doi: 10.1007/s00330-005-0110-4. [DOI] [PubMed] [Google Scholar]
  • 20.Bae KT, Seeck BA, Hildebolt CF, et al. Contrast enhancement in cardiovascular MDCT: Effect of body weight, height, body surface area, body mass index, and obesity. AJR Am. J. Roentgenol. 2008;190:777–784. doi: 10.2214/AJR.07.2765. [DOI] [PubMed] [Google Scholar]
  • 21.Pazhenkottil AP, Husmann L, Buechel RR, et al. Validation of a new contrast material protocol adapted to body surface area for optimized low-dose CT coronary angiography with prospective ECG-triggering. Int. J. Cardiovasc Imaging. 2010;26:591–597. doi: 10.1007/s10554-010-9594-3. [DOI] [PubMed] [Google Scholar]
  • 22.Yu Y, Yin W, Liao K, et al. Individualized contrast agents injection protocol tailored to body surface area in coronary computed tomography angiography [published online ahead of print May 12, 2019] Acta Radiol. 2019 doi: 10.1177/0284185119840769. [DOI] [PubMed] [Google Scholar]
  • 23.Benz DC, Grani C, Hirt MB, et al. A low-dose and an ultra-low-dose contrast agent protocol for coronary CT angiography in a clinical setting: Quantitative and qualitative comparison to a standard dose protocol. Br. J. Radiol. 2017;90:20160933. doi: 10.1259/bjr.20160933. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Mosteller RD. Simplified calculation of body-surface area. N. Engl. J. Med. 1987;317:1098. doi: 10.1056/NEJM198710223171717. [DOI] [PubMed] [Google Scholar]
  • 25.Bai B, Teliewubai J, Lu Y, et al. Comparison of pulse wave velocity and pulse pressure amplification in association with target organ damage in community-dwelling elderly: The Northern Shanghai Study. Hypertens. Res. 2018;41:372–381. doi: 10.1038/s41440-018-0027-3. [DOI] [PubMed] [Google Scholar]
  • 26.Yin WH, Lu B, Li N, et al. Iterative reconstruction to preserve image quality and diagnostic accuracy at reduced radiation dose in coronary CT angiography: An intraindividual comparison. JACC Cardiovasc. Imaging. 2013;6:1239–1249. doi: 10.1016/j.jcmg.2013.08.008. [DOI] [PubMed] [Google Scholar]
  • 27.Özbek K, Ceyhan K, Koç F, et al. The protective effect of single dose tadalafil in contrast-induced nephropathy: An experimental study. Anatol. J. Cardiol. 2015;15:306–310. doi: 10.5152/akd.2014.5380. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Yeganehkhah MR, Iranirad L, Dorri F, et al. Comparison between three supportive treatments for prevention of contrast-induced nephropathy in high-risk patients undergoing coronary angiography. Saudi J. Kidney Dis. Transpl. 2014;25:1217–1223. doi: 10.4103/1319-2442.144255. [DOI] [PubMed] [Google Scholar]
  • 29.Messerli M, Dewes P, Scholtz JE, et al. Evaluation of an adaptive detector collimation for prospectively ECG-triggered coronary CT angiography with third-generation dual-source CT. Eur. Radiol. 2018;28:2143–2150. doi: 10.1007/s00330-017-5177-1. [DOI] [PubMed] [Google Scholar]
  • 30.Gordic S, Husarik DB, Desbiolles L, Leschka S, Frauenfelder T, Alkadhi H. High-pitch coronary CT angiography with third generation dual-source CT: Limits of heart rate. Int. J. Cardiovasc. Imaging. 2014;30:1173–1179. doi: 10.1007/s10554-014-0445-5. [DOI] [PubMed] [Google Scholar]
  • 31.Muenzel D, Noel PB, Dorn F, Dobritz M, Rummeny EJ, Huber A. Step and shoot coronary CT angiography using 256-slice CT: Effect of heart rate and heart rate variability on image quality. Eur. Radiol. 2011;21:2277–2284. doi: 10.1007/s00330-011-2185-4. [DOI] [PubMed] [Google Scholar]
  • 32.Meng L, Cui L, Cheng Y, et al. Effect of heart rate and coronary calcification on the diagnostic accuracy of the dual-source CT coronary angiography in patients with suspected coronary artery disease. Korean J. Radiol. 2009;10:347–354. doi: 10.3348/kjr.2009.10.4.347. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Achenbach S, Marwan M, Schepis T, et al. High-pitch spiral acquisition: A new scan mode for coronary CT angiography. J. Cardiovasc. Comput. Tomogr. 2009;3:117–121. doi: 10.1016/j.jcct.2009.02.008. [DOI] [PubMed] [Google Scholar]
  • 34.Weustink AC, Neefjes LA, Kyrzopoulos S, et al. Impact of heart rate frequency and variability on radiation exposure, image quality, and diagnostic performance in dual-source spiral CT coronary angiography. Radiology. 2009;253:672–680. doi: 10.1148/radiol.2533090358. [DOI] [PubMed] [Google Scholar]
  • 35.Brodoefel H, Burgstahler C, Tsiflikas I, et al. Dual-source CT: Effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy. Radiology. 2008;247:346–355. doi: 10.1148/radiol.2472070906. [DOI] [PubMed] [Google Scholar]
  • 36.Wang W, Zhao YE, Qi L, et al. Prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp with 30 mL contrast agent: An intraindividual comparison with sequential scanning at 120 kVp with 60mL contrast agent. Eur. J. Radiol. 2017;90:97–105. doi: 10.1016/j.ejrad.2017.02.020. [DOI] [PubMed] [Google Scholar]
  • 37.Renker M, Ramachandra A, Schoepf UJ, et al. Iterative image reconstruction techniques: Applications for cardiac CT. J. Cardiovasc. Comput. Tomogr. 2011;5:225–230. doi: 10.1016/j.jcct.2011.05.002. [DOI] [PubMed] [Google Scholar]
  • 38.Moscariello A, Takx RA, Schoepf UJ, et al. Coronary CT angiography: Image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique-comparison with traditional filtered back projection. Eur. Radiol. 2011;221:2130–2138. doi: 10.1007/s00330-011-2164-9. [DOI] [PubMed] [Google Scholar]
  • 39.Sabarudin A, Sun Z, Ng KH. A systematic review of radiation dose associated with different generations of multidetector CT coronary angiography. J. Med. Imaging Radiat. Oncol. 2012;56:5–17. doi: 10.1111/j.1754-9485.2011.02335.x. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials


Articles from Scientific Reports are provided here courtesy of Nature Publishing Group

RESOURCES