. 2020 May 22;8(5):e2815. doi: 10.1097/GOX.0000000000002815

The Use of Cold Atmospheric Plasma Device in Flap Elevation

Massimo Pinelli 1, Marta Starnoni 1,, Giorgio De Santis 1
PMCID: PMC7572129  PMID: 33133892

Dear Sir,

We have found a lot of interest in the use of a cold atmospheric plasma device (Renuvion/J-Plasma; Apyx Medical, Clearwater, Fla.). This surgical instrument can be used for both therapeutic and cosmetic applications. It has been used in different fields (from general to gynecology surgery) for open and laparoscopic cases.1 In plastic/cosmetic surgery, radio frequency helium plasma has been shown to be very effective for skin rejuvenation and skin tightening and also for rhinophyma reduction and skin cancer treatment.2

We have focused our attention on the use of J-Plasma in flap elevation. In fact, in an attempt to improve and enhance surgical techniques and patient care, the use of surgical instruments different from traditional electrosurgery for flap elevation is widely described in the literature. For example, the use of harmonic scalpel has been reported in the latissimus dorsi, deep inferior epigastric perforator, and fibula flap harvest.35

The technical advantages of J-Plasma when compared with conventional electrosurgical devices include minimal lateral and depth of thermal spread, a high level of precision, and less smoke, odor, and eschar. Moreover, the ability to provide consistent power across a wide range of tissue impedances makes it effective on many tissue types.2

We have experienced this surgical instrument for the dissection of osteoseptocutaneous flaps (12 cases of fibula free flap), fasciocutaneous flaps (10 cases of radial free forearm flap) (Fig. 1), and musculocutaneous flaps (15 cases of latissimus dorsi flap) without any observed complications. The setting of the instrument used was different in fibula free flap (J-Plasma mode, at 4-L flow and 30% power), radial free forearm flap (J-Plasma mode, at 3-L flow and 20% power), and latissimus dorsi flap (J-Plasma mode, at 4-L and 50% power) harvest.

Fig. 1.

Fig. 1.

Use of cold atmospheric plasma device in radial-free forearm flap elevation.

We would like to share our experience in the attempt to facilitate the setting of this instrument for plastic surgeons interested in its use in flap elevation.

In our experience, we have observed significant differences between the use of the J-Plasma cool helium plasma and the traditional monopolar electrosurgery in flap elevation such as simultaneous tissue dissection and hemostasis, the absence of muscle contraction, the absence of fat necrosis without oil formation and tissue burn during dissection, and surgeons' reduced fear of unintended tissue trauma.

Our limited use in few cases, coupled with good outcomes, has allowed us to continue with the use of this surgical device moving forward. In our opinion, this instrumental device can be very useful in plastic surgery not only for skin tightening but also for pedicle and free flap elevation utilizing the proper settings.

DISCLOSURE

The authors have no financial interest to declare in relation to the content of this article.

Footnotes

Published online 22 May 2020.

REFERENCES

  • 1.Pedroso JD, Gutierrez MM, Volker KW, et al. Thermal effect of J-plasma(R) energy in a porcine tissue model: implications for minimally invasive surgery. Surg Technol Int. 2017;30:19–24. [PubMed] [Google Scholar]
  • 2.Gentile RD.Renuvion/J-plasma for subdermal skin tightening facial contouring and skin rejuvenation of the face and neck. Facial Plast Surg Clin North Am. 2019;27:273–290. [DOI] [PubMed] [Google Scholar]
  • 3.Starnoni M, De Santis G, Pinelli M.Fibula free flap elevation without tourniquet: are harmonic scalpel shears useful? Plast Reconstr Surg Glob Open. 2019;7:e2409. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Baccarani A, Starnoni M, De Santis G.Ultrasonic cutting and coagulating device in implant-based breast reconstruction. Plast Reconstr Surg Glob Open. 2018;6:e2020. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Lee YJ, Kim HY, Han HH, et al. Comparison of dissection with harmonic scalpel and conventional bipolar electrocautery in deep inferior epigastric perforator flap surgery: a consecutive cohort study. J Plast Reconstr Aesthet Surg. 2017;70:222–228. [DOI] [PubMed] [Google Scholar]

Articles from Plastic and Reconstructive Surgery Global Open are provided here courtesy of Wolters Kluwer Health

RESOURCES