Skip to main content
BMC Ophthalmology logoLink to BMC Ophthalmology
. 2020 Oct 20;20:422. doi: 10.1186/s12886-020-01693-6

The changes of corneal biomechanical properties with long-term treatment of prostaglandin analogue measured by Corvis ST

Na Wu 1,2,3, Yuhong Chen 1,2,3,, Yaping Yang 1,2,3, Xinghuai Sun 1,2,3,4
PMCID: PMC7576693  PMID: 33081750

Abstract

Background

To investigate the corneal biomechanical changes in primary open angle glaucoma (POAG) patients treated with long-term prostaglandin analogue (PGA).

Methods

One hundred eleven newly diagnosed POAG patients, including 43 high tension glaucoma (HTG) and 68 normal tension glaucoma (NTG), were measured by Corvis ST to obtain intraocular pressure (IOP), central corneal thickness (CCT) and corneal biomechanical parameters at baseline and at each follow-up visit after initiation of PGA treatment. The follow-up measurements were analyzed by the generalized estimate equation model with an exchangeable correlation structure. Restricted cubic spline was employed to estimate the dose–response relation between follow-up time and corneal biomechanics.

Results

The mean follow-up time was 10.3 ± 7.02 months. Deformation amplitude (β = -0.0015, P = 0.016), the first applanation velocity (AV1, β = -0.0004, P = 0.00058) decreased and the first applanation time (AT1, β = 0.0089, P < 0.000001) increased statistically significantly with PGA therapy over time after adjusting for age, gender, axial length, corneal curvature, IOP and CCT. In addition, AT1 was lower (7.2950 ± 0.2707 in NTG and 7.5889 ± 0.2873 in HTG, P = 0.00011) and AV1 was greater (0.1478 ± 0.0187 in NTG and 0.1314 ± 0.0191 in HTG, P = 0.00002) in NTG than in HTG after adjusting for confounding factors.

Conclusions

Chronic use of PGA probably influences the corneal biomechanical properties directly, which is to make cornea less deformable. Besides, corneas in NTG tended to be more deformable compared to those in HTG with long-term treatment of PGA.

Keywords: Prostaglandin analogue, Corneal biomechanical properties, Glaucoma, Corvis ST

Background

Corneal biomechanical properties have recently attracted increasing attention for its involvement in glaucoma and in other ocular diseases, such as keratoconus [1]. The biomechanical properties of cornea may determine its deformation response to applanation, which influences the intraocular pressure (IOP) measurement [2, 3]. In addition, it has been speculated that corneal biomechanics may represent structural vulnerabilities of the whole eyeball to the development of glaucoma [46]. Thus, understanding corneal biomechanics is helpful to improve the diagnosis and management of glaucoma [2, 3, 7].

Primary open angle glaucoma (POAG) is the most common type of glaucoma worldwide. Prostaglandin analogue (PGA) is the first-line hypotensive medication for POAG currently. Long-term use of PGA has been reported to decrease the central corneal thickness (CCT) due to activation of corneal stromal matrix metalloproteinases (MMPs) [8, 9]. Experimental studies also indicate that PGA causes morphological and biochemical changes of corneal stroma [10]. These changes imply that corneal biomechanical properties could possibly be affected by PGA.

Most of the available studies about corneal biomechanics were conducted by using the Ocular Response Analyzer (ORA) [11]. ORA is the first developed device, which is able to provide an in vivo measurement of corneal viscoelastic parameter called corneal hysteresis (CH) [12]. CH is shown to be decreased in glaucomatous eyes compared to that in normal controls [13] and associated with visual field progression in glaucomatous eyes [7].

The Corneal Visualization Scheimpflug Technology (Corvis ST) is a newly available non-touch instrument that provides precise, repeatable, and reproducible measurements of corneal biomechanics in vivo [11, 14]. The Corvis ST uses an ultra-high-speed Scheimpflug camera to record corneal deformation in real time and provides direct information on corneal biomechanical behavior [15] and could potentially provide more information on corneal biomechanics than ORA [16].

Our previous study conducted by Corvis ST observed significant differences in biomechanical parameters between treatment naïve POAG patients and patients with long-term therapy of PGA, even after adjusting for other confounding factors that might influence biomechanics, such as IOP and CCT [17]. The results suggested that PGA might have a potential effect on corneal biomechanical properties in addition to its indirect effect owning to IOP decrease and CCT reduction [17]. However, due to the cross-sectional design, the influence of PGA on corneal biomechanics remains unanswered. In this study, we prospectively followed up newly diagnosed POAG patients under PGA treatment to observe the changes of corneal biomechanical properties over time.

Methods

This research was approved by the Medical Ethics Committee of Eye and ENT Hospital of Fudan University, and adhered to the Declaration of Helsinki. Written informed consents were obtained from all of the participants.

Patients who were newly diagnosed with POAG were recruited consecutively at Eye and ENT Hospital of Fudan University. POAG was diagnosed with the criteria as follows: an open anterior chamber angle on gonioscopy examination, characteristic glaucomatous optic disc changes (thinning of the optic disc rim and/or enlargement of the optic disc cupping) with corresponding visual field defects: (1) glaucoma hemifield test values outside the normal limits; or (2) three or more abnormal points with a probability of being normal of P < 5%, of which at least one point has a pattern deviation of P < 1%; or (3) a pattern standard deviation of P < 5%. In addition, patients were diagnosed with high tension glaucoma (HTG) when they had at least one measurement of IOP > 21 mmHg with a Goldmann applanation tonometer. Patients diagnosed as normal tension glaucoma (NTG) had an IOP ≤ 21 mmHg at all time points on a 24-h IOP variation test. Patients who received continuous therapy of only one type of PGA medication were enrolled in the study. Exclusion criteria included any coexisted ocular conditions such as corneal diseases, previous history of ocular laser or surgical treatment, which might affect corneal biomechanics. Secondary glaucoma, such as trauma, uveitis and steroid induced glaucoma, was excluded as well.

All participants underwent a comprehensive ophthalmologic examination when they were first enrolled in the study, including best corrected visual acuity, slit-lamp biomicroscopy, fundus evaluation with a 90D lens, gonioscopy examination, automated perimetry (Humphrey Field Analyzer, Carl Zeiss, USA) and the retinal nerve fiber layer thickness on optical coherence tomography (OCT) (Optovue RTVue OCT, USA). Axial length and corneal curvature were measured by IOL Master (Zeiss, Germany).

The Corvis ST (Oculus, GmbH, Wetzlar, Germany) not only measures IOP, biomechanically corrected IOP (bIOP), CCT, but also provides parameters of corneal biomechanical properties by exerting an air impulse on the cornea. Under the pressure, the cornea bends inward from the resting state to the first applanation point and continues to move until reaches the maximum deformation state, namely highest concavity (HC). When the pressure of air puff decreases, the cornea moves outward and passes the second applanation point before arriving at its resting state [11, 14]. The biomechanical parameters used in this study were: 1) time from the resting state to the first and second applanations (AT1 and AT2, respectively); 2) corneal velocity during the first and second applantions (AV1 and AV2, respectively); 3) highest concavity time (HC-time) and maximum deformation amplitude (DA) from the resting state to the HC at the corneal apex; peak distance between corneal bending points (HC-PD) and radius of curvature (HC-radius) at HC [11, 14, 18].

Patients were examined by Corvis ST at baseline and at each follow-up visit. Both eyes were included if they were eligible. Single eyes were selected on 7 patients because the other ones could not obtain reliable measurements. It should be noted that only Corvis ST measurements of post-treatment of PGA were used for statistical analysis.

Statistical analyses were performed with R 3.3 (https://www.R-project.org).

Descriptive statistical results were presented as the mean ± standard deviation (SD). The repeated follow-up measurements were analyzed by the generalized estimate equation model with an exchangeable correlation structure. Restricted cubic spline was employed to estimate the dose–response relation between follow-up time and IOP, CCT and corneal biomechanical parameters with adjustment. Independent samples t test and chi-square test were used for comparison of demographic (age and gender) and clinical (axial length and corneal curvature) measurements between NTG and HTG groups. It was considered statistically significant if the P value was less than 0.05.

Results

The examined group consisted of 111 newly diagnosed POAG patients, including 43 female and 68 male with a mean age of 48.04 ± 14.14 years (22—82 years). Together, 215 eyes were examined (both eyes from 104 subjects and 7 eyes from 7 subjects). The mean follow-up time was 10.3 ± 7.02 months (1.15—41.57 months). Subjects had an average of 2.53 ± 1.42 (1–7) times of follow-up visits in the study. The mean axial length and corneal curvature of the total subjects were 25.6 ± 1.77 mm and 7.75 ± 0.24 mm, respectively (Table 1). A slight but statistically significant decrease in IOP (β = -0.0596, P = 0.000047), bIOP (β = -0.0369, P = 0.0029) and CCT (β = -0.6639, P < 0.000001) was observed during the period of PGA usage (Table 2, Fig. 1).

Table 1.

Demographic, clinical and diagnostic characteristics of 111 newly diagnosed primary open angle glaucoma patients participating in the study

Category
Age, years 48.04 ± 14.14 (22–82)
Gender
 Female 43 (38.7%)
 Male 68 (61.3%)
Follow-up period, months 10.3 ± 7.02 (1.15—41.57)
Follow-up times 2.53 ± 1.42 (1–7)
Diagnosis
 High tension glaucoma (HTG) 43 (38.7%)
 Normal tension glaucoma (NTG) 68 (61.3%)
Axial length, mm 25.6 ± 1.77
Corneal curvature, mm 7.75 ± 0.24

Table 2.

The changes of IOP, bIOP and CCT in POAG patients under PGA treatment over time

β 95% CI P value
IOP -0.0596 -0.0883 to -0.0309 0.000047
bIOP -0.0369 -0.0612 to -0.0126 0.0029
CCT -0.6639 -0.8048 to -0.5230  < 0.000001

IOP intraocular pressure, bIOP biomechanically corrected intraocular pressure, CCT central corneal thickness, POAG primary open angle glaucoma, PGA prostaglandin analogue

Fig. 1.

Fig. 1

The changes of IOP (a), bIOP (b) and CCT (c) in POAG patients under PGA treatment over time

Generalized estimate equation model with an exchangeable correlation structure was used to observe the corneal biomechanical changes with PGA treatment over time. After adjusting for age, gender, axial length, corneal curvature, IOP and CCT, AT1 increased (β = 0.0089, P < 0.000001), whereas DA and AV1 decreased statistically significantly over time (β = -0.0015, P = 0.016 for DA; β = -0.0004, P = 0.00058 for AV1) (Table 3, Fig. 2). Other corneal biomechanical parameters showed no statistically significant changes over time (Table 3).

Table 3.

The changes of corneal biomechanical parameters in POAG patients under PGA treatment over time with adjustment for age, gender, axial length, corneal curvature, IOP and CCT

Corneal biomechanical parameters After adjustment
β P value
DA -0.0015 0.016
AT1 0.0089  < 0.000001
AV1 -0.0004 0.00058
AT2 -0.0059 0.139
AV2 0.0003 0.364
HC-time -0.0044 0.272
HC-PD -0.0023 0.196
HC-radius -0.0076 0.346

POAG primary open angle glaucoma, PGA prostaglandin analogue, IOP intraocular pressure, CCT central corneal thickness, DA deformation amplitude, AT1 the first applanation time, AV1 the first applanation velocity, AT2 the second applanation time, AV2 the second applanation velocity, HC the highest concavity, PD peak distance

Fig. 2.

Fig. 2

The changes of DA (a), AT1 (b), AV1 (c) and AT2 (d) in POAG patients under PGA treatment over time

In addition, we analyzed the differences of corneal biomechanical parameters between NTG and HTG groups under PGA treatment over time. Among the 111 POAG patients, 68 were NTG patients and the other 43 were HTG (Table 1). There were no statistically significant differences in age, gender, axial length and corneal curvature between these two groups (all P > 0.05, Table 4). IOP, bIOP and CCT of post-treatment of PGA in NTG group were all statistically significantly lower than those in HTG group (all P < 0.0001, Table 4). After correcting for age, gender, axial length, corneal curvature, IOP and CCT, AT1 was lower (7.2950 ± 0.2707 in NTG and 7.5889 ± 0.2873 in HTG, P = 0.00011, Fig. 3a) and AV1 was higher (0.1478 ± 0.0187 in NTG and 0.1314 ± 0.0191 in HTG, P = 0.00002, Fig. 3b) in NTG group compared to that in HTG group with statistically significant differences (Table 5).

Table 4.

Differences in demographic and clinical characteristics between NTG and HTG groups

NTG (n = 68) HTG (n = 43) P value
Age (male) 49.15 ± 14.51 46.28 ± 13.50 0.292
Gender 41 (60.3%) 27 (62.8%) 0.843
Axial length 25.52 ± 1.81 25.74 ± 1.70 0.374
Corneal curvature 7.76 ± 0.22 7.75 ± 0.27 0.826
IOP 16.05 ± 2.36 18.47 ± 2.36  < 0.0001
bIOP 15.37 ± 2.09 16.90 ± 2.10  < 0.0001
CCT 537.44 ± 32.13 564.35 ± 27.96  < 0.0001

NTG normal tension glaucoma, HTG high tension glaucoma, IOP intraocular pressure, bIOP biomechanically corrected intraocular pressure, CCT central corneal thickness

Fig. 3.

Fig. 3

The changes of AT1 (a) and AV1 (b) in NTG and HTG patients under PGA treatment over time

Table 5.

Differences in corneal biomechanical parameters between NTG and HTG groups under PGA treatment over time after adjusting for age, gender, axial length, corneal curvature, IOP and CCT

NTG (n = 68) HTG (n = 43) P value
DA 1.1070 ± 0.1115 1.0425 ± 0.1248 0.681
AT1 7.2950 ± 0.2707 7.5889 ± 0.2873 0.00011
AV1 0.1478 ± 0.0187 0.1314 ± 0.0191 0.00002
AT2 21.8646 ± 0.6164 21.6138 ± 0.5827 0.173
AV2 -0.2682 ± 0.0580 -0.2551 ± 0.0426 0.709
HC-time 16.8531 ± 0.5389 16.8520 ± 0.8962 0.477
HC-PD 5.0539 ± 0.2704 4.8712 ± 0.3023 0.241
HC-radius 6.5643 ± 0.9992 6.8861 ± 2.5276 0.428

NTG normal tension glaucoma, HTG high tension glaucoma, PGA prostaglandin analogue, IOP intraocular pressure, CCT central corneal thickness, DA deformation amplitude, AT1 the first applanation time, AV1 the first applanation velocity, AT2 the second applanation time, AV2 the second applanation velocity, HC the highest concavity, PD peak distance

Discussion

PGA is the most widely used first-line therapeutic medication for POAG due to its highest effectiveness in decreasing IOP [19] and reducing circadian IOP fluctuations, as well as its convenient dosing and tolerable side effects [20]. However, PGA was found to have some other effects, such as decreasing the thickness of central cornea. Our results showed CCT declined under treatment of PGA over time, which was in accordance with previous studies [21, 22], implying a possible time cumulative effect of PGA on cornea tissue. The mechanisms of CCT reduction are possibly due to the MMPs up-regulation and extracellular matrix degradation stimulated by PGA in the cornea [8, 9, 23].

The cornea is considered to have both viscous and elastic properties [1]. Studies conducted on the ORA showed that IOP decreased and CH increased significantly after topical PGA treatment [24, 25]. Increased CH indicates an increased corneal viscoelastic response [26]. IOP is a significant influencing factor of corneal deformation [1, 27] and should always be taken into account when analyzing corneal biomechanics. Hence, to better elucidate the corneal biomechanical changes with long-term treatment of PGA and to avoid the influences of IOP sudden decrease on it, baseline Corvis ST measurements, namely those before initiation of PGA treatment, were not analyzed.

In this study, we showed that DA, AT1 and AV1 changed with statistical significances under PGA therapy over time. Since the results were adjusted for age, gender, axial length, corneal curvature, IOP and CCT, it suggested long-term use of PGA might influence the corneal biomechanics directly. Our observation was consistent with an previous observational study, which found CH increased significantly after 6 months treatment of PGA on newly diagnosed POAG patients measured by ORA, and this increase was only significantly correlated with basal IOP but not with the drug induced IOP reduction, suggesting PGA could have a direct effect on cornea biomechanical properties [25].

A more deformable cornea is characterized by reaching the first applanation faster (with shorter AT1 and greater AV1), the second applanation slower (with longer AT2 and lower AV2) and the highest concavity with greater DA [14]. In our study, although not all of the biomechanical parameters reached statistical significances, DA (β = -0.0015), AV1 (β = -0.0004) and AT2 (β = -0.0059) decreased and AT1 (β = 0.0089) increased as PGA treatment time extended after adjusting for potential confounding factors. Based on the meanings of the parameters, our results indicated a less deformable cornea as PGA treatment prolonged.

Our observations were supported by a few previous studies as follows. Hussnain et al. observed a significant decrease in CH among medication, laser or surgery treated POAG patients in a retrospective study [28]. They hypothesized that CH decreased over time in POAG patients even though increased in a short term with therapies to reduce IOP [28]. However, the percentages and types of medical treatment were not mentioned in their publication. Another recent prospective study conducted by Meda et al. showed that POAG patients with long-term PGA therapy for at least 1 year had significantly lower CH values than those whose PGA were discontinued [12], which indicated that long-term use of PGA might cause CH decrease.

Pathogenesis differences between NTG and HTG have been investigated by many studies. Factors other than IOP probably contribute more to the onset and development of NTG. Interestingly, we found there were statistically significant differences in corneal biomechanical parameters under PGA treatment between NTG and HTG groups. After adjusting for age, gender, axial length, corneal curvature, IOP and CCT, AT1 was shorter and AV1 was greater in NTG than in HTG, which means that corneas in NTG tend to be more deformable compared to those in HTG with the extension of PGA treatment.

To our knowledge, this is the first prospective study investigating the long-term changes of corneal biomechanical properties with chronic use of PGA measured by Corvis ST. However, some of the limitations need to be considered. The patient profile may not necessarily represent the whole population data because of our clinic-based design. Furthermore, the patients had variant follow-up times and different intervals between visits, which could potentially introduce bias into current results.

Conclusions

Our study indicated that long-term treatment of PGA might make cornea less deformable. It should be taken into consideration when analyzing corneal biomechanics in patients with PGA treatment. We speculate the corneal extracellular matrix remodeling may be involved, although the underlying mechanisms remain unknown. It would be interesting for further studies to validate these changes at a molecular level.

Acknowledgements

We are grateful to the glaucoma patients who participated in the study.

Abbreviations

AT1

The first applanation time

AT2

The second applanation time

AV1

The first applanation velocity

AV2

The second applanation velocity

bIOP

Biomechanically corrected IOP

CCT

Central corneal thickness

CH

Corneal hysteresis

Corvis ST

Corneal Visualization Scheimpflug Technology

DA

Deformation amplitude

HC

Highest concavity

HC

Highest concavity

HTG

High tension glaucoma

IOP

Intraocular pressure

MMPs

Matrix metalloproteinases

NTG

Normal tension glaucoma

OCT

Optical coherence tomography

ORA

Ocular Response Analyzer

PD

Peak distance

PGA

Prostaglandin analogue

POAG

Primary open angle glaucoma

SD

Standard deviation

Authors’ contributions

YC and XS conceived and designed the study. NW and YY collected the data. YC and NW performed the statistical analysis, interpreted the data and drafted the manuscript. All authors contributed to manuscript revision, read and approved the submitted version and the authorship list.

Funding

Supported by funds from the National Science Foundation of China [No. 81570887 and No. 81600730]; the Shanghai Committee of Science and Technology [No. 17410712500] and the top priority of clinical medicine center of Shanghai [No. 2017ZZ01020]. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.

Availability of data and materials

The raw data may be made available upon reasonable request from the corresponding author.

This research was approved by the Medical Ethics Committee of Eye and ENT Hospital of Fudan University (KY2012001), and adhered to the Declaration of Helsinki. Written informed consents were obtained from all of the participants.

Ethics approval and consent to participate

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interest.

Footnotes

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.Ali NQ, Patel DV, McGhee CN. Biomechanical responses of healthy and keratoconic corneas measured using a noncontact scheimpflug-based tonometer. Invest Ophthalmol Vis Sci. 2014;55:3651–3659. doi: 10.1167/iovs.13-13715. [DOI] [PubMed] [Google Scholar]
  • 2.Liu J, Roberts CJ. Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis. J Cataract Refract Surg. 2005;31:146–155. doi: 10.1016/j.jcrs.2004.09.031. [DOI] [PubMed] [Google Scholar]
  • 3.Medeiros FA, Weinreb RN. Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the ocular response analyzer. J Glaucoma. 2006;15:364–370. doi: 10.1097/01.ijg.0000212268.42606.97. [DOI] [PubMed] [Google Scholar]
  • 4.Sigal IA, Flanagan JG, Ethier CR. Factors influencing optic nerve head biomechanics. Invest Ophthalmol Vis Sci. 2005;46:4189–4199. doi: 10.1167/iovs.05-0541. [DOI] [PubMed] [Google Scholar]
  • 5.Johnson CS, Mian SI, Moroi S, Epstein D, Izatt J, Afshari NA. Role of corneal elasticity in damping of intraocular pressure. Invest Ophthalmol Vis Sci. 2007;48:2540–2544. doi: 10.1167/iovs.06-0719. [DOI] [PubMed] [Google Scholar]
  • 6.Wells AP, Garway-Heath DF, Poostchi A, Wong T, Chan KC, Sachdev N. Corneal hysteresis but not corneal thickness correlates with optic nerve surface compliance in glaucoma patients. Invest Ophthalmol Vis Sci. 2008;49:3262–3268. doi: 10.1167/iovs.07-1556. [DOI] [PubMed] [Google Scholar]
  • 7.Congdon NG, Broman AT, Bandeen-Roche K, Grover D, Quigley HA. Central corneal thickness and corneal hysteresis associated with glaucoma damage. Am J Ophthalmol. 2006;141:868–875. doi: 10.1016/j.ajo.2005.12.007. [DOI] [PubMed] [Google Scholar]
  • 8.Sen E, Nalcacioglu P, Yazici A, Aksakal FN, Altinok A, Tuna T, et al. Comparison of the effects of latanoprost and bimatoprost on central corneal thickness. J Glaucoma. 2008;17:398–402. doi: 10.1097/IJG.0b013e31815d784c. [DOI] [PubMed] [Google Scholar]
  • 9.Kocabeyoglu S, Mocan MC, Irkec M. Decreased keratocyte density and central corneal thickness in primary open-angle glaucoma patients undergoing treatment with topical prostaglandin analogues. Indian J Ophthalmol. 2015;63:15–19. doi: 10.4103/0301-4738.151456. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Wu KY, Wang HZ, Hong SJ. Effect of latanoprost on cultured porcine corneal stromal cells. Curr Eye Res. 2005;30:871–879. doi: 10.1080/02713680591006237. [DOI] [PubMed] [Google Scholar]
  • 11.Chansangpetch S, Panpruk R, Manassakorn A, Tantisevi V, Rojanapongpun P, Hurst CP, et al. Impact of Myopia on Corneal Biomechanics in Glaucoma and Nonglaucoma Patients. Invest Ophthalmol Vis Sci. 2017;58:4990–4996. doi: 10.1167/iovs.17-22219. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Meda R, Wang Q, Paoloni D, Harasymowycz P, Brunette I. The impact of chronic use of prostaglandin analogues on the biomechanical properties of the cornea in patients with primary open-angle glaucoma. Br J Ophthalmol. 2017;101:120–125. doi: 10.1136/bjophthalmol-2016-308432. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Shin J, Lee JW, Kim EA, Caprioli J. The effect of corneal biomechanical properties on rebound tonometer in patients with normal-tension glaucoma. Am J Ophthalmol. 2015;159:144–154. doi: 10.1016/j.ajo.2014.10.007. [DOI] [PubMed] [Google Scholar]
  • 14.Salvetat ML, Zeppieri M, Tosoni C, Felletti M, Grasso L, Brusini P. Corneal Deformation Parameters Provided by the Corvis-ST Pachy-Tonometer in Healthy Subjects and Glaucoma Patients. J Glaucoma. 2015;24:568–574. doi: 10.1097/IJG.0000000000000133. [DOI] [PubMed] [Google Scholar]
  • 15.Hon Y, Lam AKC. Corneal Deformation Measurement Using Scheimpflug Noncontact Tonometry. Optom Vis Sci. 2013;90:E1–E8. doi: 10.1097/OPX.0b013e318279eb87. [DOI] [PubMed] [Google Scholar]
  • 16.Wang W, Du S, Zhang X. Corneal Deformation Response in Patients With Primary Open-Angle Glaucoma and in Healthy Subjects Analyzed by Corvis ST. Invest Ophthalmol Vis Sci. 2015;56:5557–5565. doi: 10.1167/iovs.15-16926. [DOI] [PubMed] [Google Scholar]
  • 17.Wu N, Chen Y, Yu X, Li M, Wen W, Sun X. Changes in Corneal Biomechanical Properties after Long-Term Topical Prostaglandin Therapy. Plos One. 2016;11:e0155527. doi: 10.1371/journal.pone.0155527. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Huseynova T, Waring GO, Roberts C, Krueger RR, Tomita M. Corneal Biomechanics as a Function of Intraocular Pressure and Pachymetry by Dynamic Infrared Signal and Scheimpflug Imaging Analysis in Normal Eyes. Am J Ophthalmol. 2014;157:885–893. doi: 10.1016/j.ajo.2013.12.024. [DOI] [PubMed] [Google Scholar]
  • 19.Li F, Huang W, Zhang X. Efficacy and safety of different regimens for primary open-angle glaucoma or ocular hypertension: a systematic review and network meta-analysis. Acta Ophthalmol. 2018;96:e277–e284. doi: 10.1111/aos.13568. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Konstas AG, Quaranta L, Katsanos A, Riva I, Tsai JC, Giannopoulos T, et al. Twenty-four hour efficacy with preservative free tafluprost compared with latanoprost in patients with primary open angle glaucoma or ocular hypertension. Br J Ophthalmol. 2013;97:1510–1515. doi: 10.1136/bjophthalmol-2012-303026. [DOI] [PubMed] [Google Scholar]
  • 21.Sawada A, Yamamoto T, Takatsuka N. Randomized crossover study of latanoprost and travoprost in eyes with open-angle glaucoma. Graefes Arch Clin Exp Ophthalmol. 2012;250:123–129. doi: 10.1007/s00417-011-1762-1. [DOI] [PubMed] [Google Scholar]
  • 22.Lee H, Cho BJ. Long-term effect of latanoprost on central corneal thickness in normal-tension glaucoma: five-year follow-up results. J Ocul Pharmacol Ther. 2015;31:152–155. doi: 10.1089/jop.2014.0109. [DOI] [PubMed] [Google Scholar]
  • 23.Lopilly Park HY, Kim JH, Lee KM, Park CK. Effect of prostaglandin analogues on tear proteomics and expression of cytokines and matrix metalloproteinases in the conjunctiva and cornea. Exp Eye Res. 2012;94:13–21. doi: 10.1016/j.exer.2011.10.017. [DOI] [PubMed] [Google Scholar]
  • 24.Tsikripis P, Papaconstantinou D, Koutsandrea C, Apostolopoulos M, Georgalas I. The effect of prostaglandin analogs on the biomechanical properties and central thickness of the cornea of patients with open-angle glaucoma: a 3-year study on 108 eyes. Drug Des Devel Ther. 2013;7:1149–1156. doi: 10.2147/DDDT.S50622. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Bolivar G, Sanchez-Barahona C, Teus M, Castejon MA, Paz-Moreno-Arrones J, Gutierrez-Ortiz C, et al. Effect of topical prostaglandin analogues on corneal hysteresis. Acta Ophthalmol. 2015;93:e495–498. doi: 10.1111/aos.12689. [DOI] [PubMed] [Google Scholar]
  • 26.Jung Y, Park HL, Yang HJ, Park CK. Characteristics of corneal biomechanical responses detected by a non-contact scheimpflug-based tonometer in eyes with glaucoma. Acta Ophthalmol. 2017;95:e556–e563. doi: 10.1111/aos.13466. [DOI] [PubMed] [Google Scholar]
  • 27.Tian L, Wang D, Wu Y, Meng X, Chen B, Ge M, et al. Corneal biomechanical characteristics measured by the CorVis Scheimpflug technology in eyes with primary open-angle glaucoma and normal eyes. Acta Ophthalmol. 2016;94:e317–324. doi: 10.1111/aos.12672. [DOI] [PubMed] [Google Scholar]
  • 28.Hussnain SA, Alsberge JB, Ehrlich JR, Shimmyo M, Radcliffe NM. Change in corneal hysteresis over time in normal, glaucomatous and diabetic eyes. Acta Ophthalmol. 2015;93:e627–630. doi: 10.1111/aos.12726. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

The raw data may be made available upon reasonable request from the corresponding author.

This research was approved by the Medical Ethics Committee of Eye and ENT Hospital of Fudan University (KY2012001), and adhered to the Declaration of Helsinki. Written informed consents were obtained from all of the participants.


Articles from BMC Ophthalmology are provided here courtesy of BMC

RESOURCES