Abstract
The λ = 2.06 μm absorption band of CO2 is widely used for the remote sensing of atmospheric carbon dioxide, making it relevant to many important top-down measurements of carbon flux. The forward models used in the retrieval algorithms employed in these measurements require increasingly accurate line intensity and line shape data from which absorption cross-sections can be computed. To overcome accuracy limitations of existing line lists, we used frequency-stabilized cavity ring-down spectroscopy to measure 39 transitions in the 12C16O2 absorption band. The line intensities were measured with an estimated relative combined standard uncertainty of ur = 0.08 %. We predicted the J-dependence of the measured intensities using two theoretical models: a one-dimensional spectroscopic model with Herman-Wallis rotation-vibration corrections, and a line-by-line ab initio dipole moment surface model [Zak et al. JQSRT 2016;177:31–42]. For the second approach, we fit only a single factor to rescale the theoretical integrated band intensity to be consistent with the measured intensities. We find that the latter approach yields an equally adequate representation of the fitted J-dependent intensity data and provides the most physically general representation of the results. Our recommended value for the integrated band intensity equal to 7.183 × 10−21 cm molecule−1 ± 6 × 10−24 cm molecule−1 is based on the rescaled ab initio model and corresponds to a fitted scale factor of 1.0069 ± 0.0002. Comparisons of literature intensity values to our results reveal systematic deviations ranging from −1.16 % to +0.33 %.
Keywords: Precision molecular spectroscopy, Line lists, Carbon dioxide, Cavity ring-down spectroscopy, Dipole moment surfaces, Herman-Wallis expansion
1. Introduction
Increasing carbon dioxide (CO2) concentrations caused by anthropogenic emissions [1] are a primary contributor to the estimated global warming of 1 °C above pre-industrial levels [2]. To understand the consequences of this trend, climate models that rely on accurate knowledge of the global carbon cycle are required. Therefore, adequate constraints on the spatial and temporal variability of CO2 fluxes are necessary.
Satellite measurements can provide the information needed to constrain CO2 sources and sinks on time and spatial scales relevant to climate modeling with validation provided by ground-based carbon-monitoring networks, such as TCCON. The GOSAT, GOSAT-2 (JAXA), OCO-2 and OCO-3 (NASA), TanSat (CAS), and the upcoming MicroCarb (CNES) missions all use satellite-based spectrometers to analyze reflected sunlight within the CO2 bands at 1.61 μm and 2.06 μm. These instruments report the atmospheric-column-integrated CO2 mole fraction (XCO2) and rely on first-principles, line-by-line radiative transfer models to account for the dependence of the absorption cross-section on wavelength, pressure, temperature, and air-composition. Absorption cross-sections are frequently calculated offline and stored in look-up tables (i.e. ABSCO [3]) to increase the speed of retrieval algorithms.
Importantly, the carbon dioxide absorption cross-sections are scaled by the intensities of the lines comprising these bands. Because spectroscopy is only part of the retrieval error budget, line intensities need to be known to a higher accuracy and precision than the XCO2 relative standard uncertainty target, which is 0.3 % for the OCO-2 mission [4]. Only recently have line intensities of such accuracy been reported for CO2 [5], and the demand for improved accuracy continues to generally motivate recent advances in related cavity-enhanced methods (e.g., [6, 7]). Beyond single lines, it is highly desirable to minimize uncertainty in the intensities of many lines to establish reliable spectroscopic constraints and band-to-band consistency when retrieving CO2 concentration from observed spectra [8]. Because systematic errors in spectroscopic parameters can bias regional XCO2 retrievals and flux estimates, reference-quality measurements of CO2 spectroscopic parameters are necessary to achieve these targets.
ABSCO v5.0 OCO-2 retrieval algorithms use line lists provided by Devi et al. [9] and Benner et al. [10] for the 1.61 μm and 2.06 μm bands, respectively. Oyafuso et al. [3] evaluated ABSCO v5.0 single-band XCO2 retrievals against TCCON retrievals, which have an estimated relative uncertainty of 0.2 % [11]. Both bands showed a clear discrepancy with the TCCON XCO2 retrievals. A joint theoretical and experimental investigation [12] into the 1.61 μm band line intensities reported agreement between the ab initio calculations and cavity ring-down spectroscopy measurements within 0.3 % and an offset between the experimental measurements and the Devi work of 1.4 %. As noted by Oyafuso et al. [3], scaling the ABSCO v5.0 absorption coefficients by this factor would bring the 1.6 μm band XCO2 estimates into much better agreement with the TCCON-reported values that were calibrated against in situ profile measurements. At the time of the Oyafuso article publication, Benner et al. [10] was the only source of reference intensities for the 2.06 μm band.
In this paper, we present new measurements of transition intensities in the 20013 ← 00001 rotation-vibration band of 12C16O2, realized using frequency-stabilized cavity ring-down spectroscopy (FS-CRDS). These measurements are compared to ab initio calculations [13] and serve as reference intensity measurements for the 2.06 μm band. Because of its higher intensity relative to the 1.61 μm band, the 2.06 μm band studied here is colloquially referred to as the “strong band”. Figure 1 shows the calculated absorbance of this strong band and the lines included in this study. The spectra were recorded in two separate sessions with slightly different experimental configurations, yielding two data sets A and B, recorded respectively in November-December 2018 and May 2019. Data set A was acquired with a suite of narrowband distributed feedback (DFB) lasers and included only the 24 lines labeled in red in Fig. 1. Data set B was acquired with a broadly tunable external cavity diode laser (ECDL), enabling measurement of all 39 labeled lines. Both sets were used for the final analysis.
Fig. 1.
Calculated absorbance spectrum of CO2 near λ = 2.06 μm (pressure p = 6.7 kPa, pathlength L = 75 cm, CO2 mole fraction μmol/mol, line parameters from HITRAN2016 [18]). The 12C16O2 transitions labeled in red were recorded in both data sets, whereas those labeled in black were only recorded in data set B (2019).
The remainder of the paper is organized as follows. The next section gives an overview of the experimental setup and the data recording procedure. Data analysis is then described, and methods for calculating the integrated band intensity from the line-by-line analysis are discussed. Specifically, we compared two models for line-by-line intensities within the 20013 ← 00001 vibrational band: a standard spectroscopic model and an ab initio quantum chemistry model. Finally, the results are discussed in comparison to the literature values, including available line lists, databases, and prior experiments.
2. Experimental setup
Previous implementations of the cavity ring-down spectrometer used herein, operating at λ ≈ 2 μm, were described in Refs. [14, 15]. The setup comprises a high-finesse length-stabilized optical cavity, a gas flow system, a probe laser, and detection apparatus, as well as a computer with a digitizer and analysis software. The spectrometer leverages the FARS (frequency-agile, rapid scanning) [16] method to scan the probe laser frequency in the vicinity of a molecular line. Figure 2 presents a simplified diagram of the experimental setup.
Fig. 2.
Simplified diagram of the FS-CRDS experimental setup (optical isolators and mode-matching optics are not shown). Acronyms: AOM, acousto-optic modulator. EOM, electro-optic modulator. DGDG, digital gate-and-delay generator. LN2, liquid nitrogen. PC, personal computer. PZT, piezoelectric actuator. RF, radiofrequency.
The optical cavity was created by two high-reflectivity, multi-wavelength-coated mirrors of power reflectivity R = 0.99994 at λ = 2 μm and R ≈ 0.95 at λ = 633 nm separated by invar rods resulting in a mirror separation of nominally 75 cm. Because the mirror coatings were designed to have maximum reflectivity at a wavelength of λ = 2 μm (), the base losses varied over the studied wave number region ( to 4885 cm−1) from 2×10−4 to 6×10−4 (decay time constant in baseline from 13 to 4 μs). One of the mirrors was mounted to a piezoelectric transducer to actively stabilize the cavity length by maintaining resonance with a reference HeNe laser with long-term frequency stability of 1 MHz [17]. The free spectral range (νFSR) of this cavity was measured and reported in Ref. [15] to be 200.07 MHz ± 0.03 MHz.
The gas sample was a NIST-certified gravimetric mixture [18] of petrochemically derived CO2 in N2 with CO2 mole fraction μmol/mol ± 0.019 μmol/mol. The isotopic composition of CO2 within the certified sample was measured via Fourier transform spectroscopy (FTS) relative to a secondary reference CO2 sample with known value assignments for δ13 CVPDB and δ18 OVPDB, where VPDB indicates the δ values are on the Vienna Pee Dee Belemnite scale. Through FTS and the secondary reference sample, the certified sample was assigned δ13 CVPDB ≈ −40 ‰. To compute the relative abundance of the 12C16O2 (626) isotopologue, we assumed δ18 OVPDB ≈ −24 ‰ which is typical of petroleum-derived carbon dioxide. Assuming a stochastic distribution of C and O isotopes yields the relative abundance χ626 = 0.98464 ± 0.00007 so that the intensities we report here were normalized to the HITRAN relative abundance value of χ626,HT = 0.984204 [19] by multiplying by the factor χ626,HT/χ626 = 0.99956 ± 0.00007.
The sample was flowed through the optical cavity after passing through a needle valve, and the intra-cavity pressure was stabilized using a voltage-controlled valve placed between the cavity gas outlet and a vacuum pump. The chosen volumetric flow rates (20 std. cm3 min−1 to 50 std. cm3 min−1) were high enough to largely eliminate the effects confounding interactions of CO2 with metal surfaces in the ring-down cavity (estimated gas residence time of 60 s), and a pressure stability of 10 Pa (about 0.1 Torr) at each setpoint was achieved over a time interval of approximately 8 h. The sample pressure was accurately measured in two steps. First, pressure was measured at a single point in the flow system (located immediately upstream of the optical cavity) by a resonant silicon manometer with a full-scale range of 130 kPa calibrated against a secondary NIST pressure standard. Second, to measure the flow-induced pressure drop between the sample gas upstream of the manometer and that within the optical measurement volume, a differential pressure measurement was performed between two points in the flow which were symmetrically located about the geometric center of the optical cavity. Analyzed in combination, the absolute and differential pressure measurements resulted in a relative combined type-B uncertainty associated with pressure of 0.02 %. The temperature was measured by a platinum resistance thermometer in good thermal contact with the outside of the metallic sample cell, and temperature stability was enhanced by surrounding the sample cell with a passive thermally insulated enclosure. Again, the temperature probe was calibrated using a secondary NIST standard.
Different probe lasers were used for the two recording sessions (data sets A and B). For data set A recorded in 2018, four different DFB laser diodes were used to measure the transitions labeled in red in Fig. 1. Before the second recording session, the DFBs were replaced by an ECDL with a tuning range from 1975 nm to 2073 nm (data set B). The rest of the optical system remained unchanged.
The fibered output of the probe laser passed through an optical isolator and was coupled into an electro-optic modulator (EOM) which generated sidebands used for FARS scanning. The frequency-modulated beam was then amplified by an optical fiber amplifier with variable gain. The amplified continuous-wave laser subsequently passed through an acousto-optic modulator (AOM) and several Faraday isolators (total optical isolation of ≥ 60 dB) and continued in free space through mode-matching optics before being injected into the optical cavity.
The probe transmission was collected by a liquid-nitrogen-cooled InSb photodetector followed by a transimpedance amplifier (105 V/A). When the transmission reached a user-defined threshold, a digital gate-and-delay generator (DGDG) triggered the decay acquisition by shuttering the incident light, acting on two optical switches simultaneously: the AOM was switched off and the EOM sideband generation was also switched off by a rapid microwave switch. The resulting decay signals were recorded by a digitizer with a resolution of 16 bits and electronic bandwidth of 125 MHz. Digitizer nonideality was independently characterized for each recording session using the procedure described in Ref. [5].
From the optical power at the photodetector at trigger threshold, and assuming a mirror power loss coefficient from absorption and scattering of 3×10−5, we estimate the intracavity intensity to be <0.4 W cm−2 with a beam waist radius ω0 = 0.56 mm — an intensity which is several orders of magnitude less than the saturation intensity [20] predicted for the strongest CO2 line studied here. Therefore, saturation effects at sample pressures >6 kPa were negligible.
Spectra were acquired for each individual line, with several replicates recorded sequentially (5 to 15 replicates for data set A, 3 for data set B) in the following manner. First, the probe laser was tuned to the center of the line and its frequency was finely adjusted to bring one of the EOM sidebands onto resonance with a TEM00 mode of the ring-down cavity. At that point, the laser frequency was dither-locked to the cavity with feedback to the laser current. Then the EOM sideband frequency was stepped in increments of νFSR from −6 GHz to +6 GHz (where a negative frequency implies that the negative sideband was in resonance with the cavity), resulting in a 60-point scan covering a 12 GHz span. At each frequency point, nominally 100 (set A) or 300 (set B) decay events were averaged. A summary of experimental conditions for data sets A and B is shown in Table 1.
Table 1.
Summary of experimental conditions for the two data sets comprising transition intensities (S) for the 20013 ← 00001 12C16O2 band near λ = 2.06 μm.
| Description | Data set A 2018 | Data set B 2019 |
|---|---|---|
| Dates recorded | 14 Nov. to 4 Dec. | 6 May to 14 May |
| Number of 12C16O2 transitions | 24 | 39 |
| Probe laser(s)a | DFB lasers (quantity 4) | ECDL |
| Probe laser linewidthb | <2 MHz | 200 kHz |
| Digitizer nonidealityc |
τcorr = b0 + b1τ b0 = 0.01078 b1 = 1.00175 |
τcorr = b0 + b1τ + b2τ2 b0 = 0.009456 b1 = 1.002414 b2 = 6.558×10−5 |
| Number of decays averaged | 100 | 300 |
| FS-CRDS precision (στ/τ) | 0.1 % to 0.5 % | 0.04 % at 4885 cm−1 to 0.12 % at 4825 cm−1 |
| DGDG trigger threshold | Variable, 0.2 V to 1.8 V | 2 V |
| Number of replicates per pressure | 5 to 15 | 3 |
| Flow rated | 20 std. cm3 min−1 | 50 std. cm3 min−1 |
| Pressure-gradient correction | None | Two-point measurement −0.17 % at 6.7 kPa −0.02 % at 20 kPa |
| Observed temperature range | 25 °C to 25.6 °C | 25.4 °C to 26 °C |
| Baseline etalon | None fitted | 2.82 GHz period |
| Line profilee | SDNGP with fixed aw = 0.08f | SDNGP with constrained aw |
| Line profile bias correctiong | −0.049 % | −0.036 % |
DFB, distributed feedback. ECDL, external cavity diode laser.
Manufacturer’s specification. Integration time: DFB, none provided; ECDL, 50 ms.
Digitizer settings: Vertical range = 10 V; Impedance = 50 Ohm; Decay fit window = variable, from 1.5 μs to 10τ.
Readout from an uncalibrated flow gage.
SDNGP, speed-dependent Nelkin-Ghatak profile.
aw = Γ2/Γ0, where Γ2 and Γ0 are the speed-dependent and velocity-averaged collisional relaxation rates [22–25].
Bias correction relative to the chosen reference profile, the Hartmann-Tran profile with η ≤ 0.5.
We note that only one value of the pressure and temperature was recorded for each individual FARS scan (90 s scan time). However, the temperature appeared to be rising continuously throughout the day (~8 h) corresponding to a change between 1 mK and 5 mK during any given scan. On the time scale of a scan, the pressure variation was below the digital resolution of the gauge (~1.3 Pa, or 0.01 Torr).
3. Data analysis
The total fractional optical power loss per unit length in the optical cavity is given by the relation
| (1) |
where c is the speed of light, τ is the decay time constant, L0 is the baseline loss divided by the cavity length (mirrors, parasitic etalons, etc.) and α is the absorption coefficient of the medium inside the cavity.
Measurements of digitizer nonidealities mentioned in the previous section resulted in a systematic correction of the recorded decay time constants by one of the following two relations: τ = b0 + b1τa (data set A) or (data set B), where τa is the raw “apparent” time constant and the coefficients {b0, b1} and {b0, b1, b2} were determined through the traceable procedure described in Ref. [5]. For data set A, digitizer nonidealities were measured using an arbitrary waveform generator (AWG) as a transfer between the digitizer under test and a metrology-grade reference digitizer, whereas for data set B, coefficients were determined directly from the unamplified AWG output which we confirmed to be consistent with the reference board. The two measurements of nonideality performed nearly 6 months apart agreed to within 0.05 %.
In both data sets, lines were recorded for 5 pressure values between 6.7 kPa and 20 kPa [(50, 75, 100, 125, 150) Torr equal to (6.7, 10, 13.3, 16.7, 20) kPa]. To account for changes in the effective cavity length with pressure, the frequency spacing between spectral data points was calculated from the empty-cavity νFSR and the known dependence of the refractive index on gas density [21].
Data analysis for each of the two data sets was performed independently. A representative analysis procedure is described here. In the first step, the spectra within each respective data set were fitted individually with a chosen line profile (Fig. 3). For a recent review of relevant line profiles and their parameters, see Ref. [22]. For data set A, the chosen line profile was a speed-dependent Nelkin-Ghatak profile (SDNGP) [23] with a fixed value for the dimensionless speed-dependent broadening parameter of aw ≡ Γ2/Γ0 = 0.08 (where Γ2 and Γ0 are the speed-dependent relaxation rate and the velocity-averaged Lorentzian halfwidth, respectively) [24, 25]. For data set B, four different line profiles were used: Galatry (GP) [26], Nelkin-Ghatak (NGP), speed-dependent Voigt (SDVP), and SDNGP. For this last profile, the dimensionless speed-dependent parameter aw was fixed to a value calculated for each line as
| (2) |
where n is the temperature exponent of the collisional broadening coefficient, and mp/ma is the perturber-to-absorber mass ratio [25]; this value of aw varied between 0.057 and 0.08 for the different lines. In all cases, floated parameters included line position (ν0 + Δ, where Δ is the pressure shift), integrated spectral area (A(T)), collisional broadening halfwidth (Γ0), Dicke narrowing frequency (νVC), and the slope and intercept of a linear background. The Doppler halfwidth (ΓD) was fixed to the theoretical value based on the measured temperature, absorber mass and transition frequency.
Fig. 3.
Sample spectra of the lines P28, P16, R2 and R24, recorded at pressures of 6.7 kPa, 13.3 kPa and 20.0 kPa in data set B. In this example, each spectrum was fitted with the speed-dependent Nelkin-Ghatak profile (SDNGP) and the resulting residuals are shown below each spectrum along with the corresponding quality factor (QF). The baseline noise amplitude scaled with the base losses and was larger in the P-branch. An etalon of period 2.82 GHz was included in the fits, and the fitted etalon amplitude also scaled with the base losses. Note that the relative vertical scale is the same for the four represented transitions.
In practice, to the extent that the chosen line profile differs from the actual line shape, the retrieved area of a transition depends on the line profile used to fit the spectral data. Indeed, systematic differences were observed in data set B between the areas retrieved using different profiles; areas obtained with NGP were typically about 0.1 % to 0.2 % lower than those obtained from SDVP, with the two other profiles falling in between those two extreme cases. Because no systematic structure was observed in the residuals, it was hard to justify which profile best represented the experimental results. To be relatively consistent with the analysis of data set A, we chose for data set B to report the line areas fitted by the most sophisticated profile: the SDNGP with constrained aw.
We evaluated bias in the choice of the line profile by fitting to a series of simulated reference profiles. Here, the reference profile is the Hartmann-Tran profile (HTP) [22] with values for the parameter describing partial correlation between velocity and rotational state changes due to collisions, η, within the range of 0 to 0.5. The upper-bound of η = 0.5 was determined empirically by establishing the value of η at which the quality factor (QF) of the fit dropped below the experimental signal-to-noise ratio. Fits to the simulated reference profiles using appropriate spectroscopic parameters for the CO2 band studied here resulted in estimates of the systematic bias for both data sets: data set A bias correction, −0.049 %; data set B bias correction, −0.036 %, relative to the chosen HTP reference profile. Both bias corrections were estimated with an uncertainty of 0.03 %.
Because of the higher signal-to-noise ratios observed for cavity decays in data set B, owing to the improved laser linewidth and higher output power of the ECDL, the background noise was reduced by comparison to data set A and an etalon of period 2.82 GHz became apparent. The phase and amplitude of this etalon were then also floated.
The integrated spectral areas A(T) were normalized to a reference temperature of Tref = 296 K using the appropriate calculated total partition function Q(T) [19, 27]:
| (3) |
where E′′ are the lower-state vibrational energies, ℎ is the Planck constant, and k is the Boltzmann constant.
Line intensities were obtained as the slope of a weighted linear regression of A296 vs. number density , where p is the sample pressure and T is the sample temperature. The intercept of this regression was fixed to zero. Figure 4 shows a representative example from data set B. All replicates were included simultaneously in the linear regression, and the weighting factors wi were derived from the fit quality factor defined earlier as , with σi = A296/QF.
Fig. 4.
Linear regression of spectral area vs. CO2 number density, for line R24 recorded in data set B. The slope of a weighted linear regression yielded the line intensity S = 2.2220 × 10−22 cm molecule−1 ± 5 × 10−26 cm molecule−1. Residuals of the linear regression are also shown, with error bars corresponding to the standard uncertainty estimated as being inversely proportional to the fit quality factor.
Spectral interferences from weak CO2 transitions were simulated and fixed during the fitting of the target CO2 transitions using Voigt line shapes and known reference data [19]. Two transitions (R16 and R28) were also affected by spectral interference from water (H2O). As a representative example from data set B, the intensity of line R16 (4866.264948 cm−1) was corrected for the contribution of an underlying water line at 4866.25151 cm−1, which was fully hidden in the spectra. The water mole fraction in the cell was estimated to be , based on observation of another isolated water transition at 4874.27767 cm−1, visible in the spectra about 5 GHz from the center of line R28. The intensity of line R28 was also corrected in this way. These corrections amounted to a relative change of −0.35(7) % for line R16 and +0.18(3) % for line R28.
While no further line-by-line corrections were required, we did perform a line-by-line analysis of the relative uncertainty contribution from weak CO2 spectral interferences. For each affected line, this uncertainty in the retrieved area for the target CO2 line was estimated as the relative change in its fitted value, when the fixed intensity of the weak interfering line was modified by an amount equal to its tabulated uncertainty in HITRAN2016 (2 % to 5 %) [19]. These line-by-line systematic uncertainty estimates from known spectral interferences are tabulated later in the paper (see Section 5.1.3, Table 4).
Table 4.
Summary of line-by-line transition intensities (S) for the 20013 ← 00001 12C16O2 vibrational band, reported in units of cm molecule−1 (abbreviated cm mlc−1). Line-by-line relative standard uncertainties (type A reproducibility and type B spectral interferences only) from the weighted regressions of A296 vs. ranged from 0.6 % to 1.6 % (data set A) and from 0.10 % to 0.6 % (data set B).
| Transition | m | Spectral interference | Data set A | Data set B | Spectroscopic model | ab initio model | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| % | S×1022cm mlc−1 | % | S×1022 cm mlc−1 | % | S×1022 cm mlc−1 | % | S×1022 cm mlc−1 | % | ||
| P34 | −34 | 0.1 | 0.984 | 0.5 | 0.9848 | 0.16 | 0.9846 | 0.02 | ||
| P32 | −32 | 0.01 | 1.185 | 0.17 | 1.1873 | 0.14 | 1.1872 | 0.02 | ||
| P30 | −30 | 0.02 | 1.404 | 0.17 | 1.4050 | 0.13 | 1.4047 | 0.02 | ||
| P28 | −28 | 0.05 | 1.610 | 0.6 | 1.633 | 0.3 | 1.6311 | 0.11 | 1.6302 | 0.02 |
| P26 | −26 | 0 | 1.846 | 0.5 | 1.858 | 0.13 | 1.8564 | 0.10 | 1.8548 | 0.02 |
| P24 | −24 | 0.01 | 2.058 | 0.5 | 2.071 | 0.13 | 2.0695 | 0.09 | 2.0682 | 0.02 |
| P22 | −22 | 0.02 | 2.246 | 0.5 | 2.257 | 0.14 | 2.2577 | 0.08 | 2.2555 | 0.02 |
| P20 | −20 | 0 | 2.406 | 0.5 | 2.412 | 0.11 | 2.4069 | 0.07 | 2.4046 | 0.02 |
| P18 | −18 | 0.03 | 2.475 | 0.5 | 2.510 | 0.17 | 2.5033 | 0.06 | 2.5012 | 0.02 |
| P16 | −16 | 0 | 2.528 | 0.5 | 2.537 | 0.11 | 2.5338 | 0.06 | 2.5314 | 0.02 |
| P14 | −14 | 0.02 | 2.481 | 0.5 | 2.491 | 0.14 | 2.4877 | 0.05 | 2.4851 | 0.02 |
| P12 | −12 | 0.01 | 2.361 | 0.5 | 2.357 | 0.12 | 2.3577 | 0.05 | 2.3552 | 0.02 |
| P10 | −10 | 0.01 | 2.142 | 0.5 | 2.138 | 0.13 | 2.1407 | 0.04 | 2.1387 | 0.02 |
| P8 | −8 | 0.01 | 1.844 | 0.5 | 1.836 | 0.13 | 1.8387 | 0.04 | 1.8366 | 0.02 |
| P6 | −6 | 0.01 | 1.458 | 0.15 | 1.4590 | 0.04 | 1.4580 | 0.02 | ||
| P4 | −4 | 0.01 | 1.009 | 0.18 | 1.0140 | 0.03 | 1.0130 | 0.02 | ||
| P2 | −2 | 0.1 | 0.5193 | 0.5 | 0.5209 | 0.03 | 0.52048 | 0.02 | ||
| R0 | 1 | 0.26372 | 0.02 | |||||||
| R2 | 3 | 0 | 0.7830 | 0.2 | 0.7837 | 0.04 | 0.7834 | 0.02 | ||
| R4 | 5 | 0 | 1.274 | 0.15 | 1.2745 | 0.04 | 1.2738 | 0.02 | ||
| R6 | 7 | 0.02 | 1.715 | 0.16 | 1.7157 | 0.04 | 1.7158 | 0.02 | ||
| R8 | 9 | 0.01 | 2.092 | 0.13 | 2.0902 | 0.05 | 2.0904 | 0.02 | ||
| R10 | 11 | 0 | 2.386 | 0.11 | 2.3853 | 0.05 | 2.3854 | 0.02 | ||
| R12 | 13 | 0.01 | 2.594 | 0.12 | 2.5937 | 0.06 | 2.5949 | 0.02 | ||
| R14 | 15 | 0.02 | 2.713 | 0.14 | 2.7134 | 0.07 | 2.7147 | 0.02 | ||
| R16a | 17 | 0.07 | 2.74 | 1.6 | 2.749 | 0.3 | 2.7474 | 0.08 | 2.7489 | 0.02 |
| R18 | 19 | 0.01 | 2.695 | 0.5 | 2.703 | 0.11 | 2.703 | 0.09 | 2.7056 | 0.02 |
| R20 | 21 | 0.02 | 2.581 | 0.5 | 2.594 | 0.14 | 2.592 | 0.10 | 2.5949 | 0.02 |
| R22 | 23 | 0.02 | 2.421 | 0.5 | 2.428 | 0.14 | 2.427 | 0.12 | 2.4297 | 0.02 |
| R24 | 25 | 0 | 2.219 | 0.5 | 2.223 | 0.12 | 2.222 | 0.13 | 2.2253 | 0.02 |
| R26 | 27 | 0.01 | 1.989 | 0.5 | 1.997 | 0.13 | 1.993 | 0.15 | 1.9947 | 0.02 |
| R28a | 29 | 0.03 | 1.737 | 0.8 | 1.750 | 0.15 | 1.751 | 0.17 | 1.7531 | 0.02 |
| R30 | 31 | 0.02 | 1.509 | 0.17 | 1.509 | 0.19 | 1.5104 | 0.02 | ||
| R32 | 33 | 0.02 | 1.272 | 0.6 | 1.274 | 0.18 | 1.276 | 0.2 | 1.2778 | 0.02 |
| R34 | 35 | 0.01 | 1.054 | 0.6 | 1.059 | 0.18 | 1.059 | 0.2 | 1.0613 | 0.02 |
| R36 | 37 | 0.01 | 0.861 | 0.6 | 0.8631 | 0.2 | 0.863 | 0.3 | 0.8651 | 0.02 |
| R38 | 39 | 0.02 | 0.692 | 0.7 | 0.6920 | 0.2 | 0.6917 | 0.3 | 0.6931 | 0.02 |
| R40 | 41 | 0 | 0.546 | 0.8 | 0.5448 | 0.3 | 0.5447 | 0.3 | 0.54576 | 0.02 |
| R42 | 43 | 0.02 | 0.421 | 0.9 | 0.4204 | 0.4 | 0.4216 | 0.4 | 0.42251 | 0.02 |
| R44 | 45 | 0.1 | 0.3205 | 0.6 | 0.3209 | 0.4 | 0.32161 | 0.02 | ||
Overlap with known spectral interference from water. Transition not included in band intensity analysis.
4. Initial uncertainty budget
Table 2 summarizes the type B (systematic) uncertainty components common to each measurement. The remainder of this section discusses estimates of the individual type A uncertainties (σm,A, long-term reproducibility) for the purposes of performing a properly weighted least-squares analysis of the vibrational band intensity in Section 5.1.
Table 2.
Type B (systematic) uncertainty budget for intensities (S) as measured by frequency-stabilized cavity ring-down spectroscopy.
| Parameter | (%) | Description |
|---|---|---|
| 0.04 | Sample mole fraction | |
| b0, b1, b2 | 0.04 | Digitizer nonideality |
| 0.03 | Choice of line profile | |
| vFSR | 0.02 | Cavity free spectral range |
| wm | 0.02 | Choice of weighting factorsa |
| p | 0.02 | Pressure and non-ideal gas effects |
| T | 0.01 | Transition-dependent T correction |
| χ626 | 0.007 | Isotopic abundance of 12C16O2 |
| 0.07 | Combined type B uncertainty | |
Weighting factors for vibrational band intensity fits, see Section 5.1.
Because of interferences from nearby water transitions as noted in Section 3, the R16 and R28 lines were not included in either the type A uncertainty evaluation presented here, or in the subsequent band fitting analysis discussed in Section 5.1. Here, we begin with a plot in Fig. 5 of the short-term type A fit uncertainties (σm,A(ST)) that resulted from individual fits of A296 vs. (e.g., Fig. 4). Data set A is plotted as red squares vs. S, and data set B is plotted as blue open circles.
Fig. 5.
Measured (symbols) and smoothed (solid lines) values for short-term type A measurement precision, σm,A(ST) plotted vs. line intensities, S. Data set A is shown as full red squares, and data set B is shown as blue open circles.
Absent a robust set of repeated measurements at each line, we chose to estimate the long-term reproducibility [28] as follows, leveraging the fact that data sets A and B are a two-point test of long-term reproducibility. In Section 5.1, we will discuss two models for predicting individual line intensities (S) from an integrated band intensity (Sband). By fitting the models in Section 5.1 to both data sets, we assume that a reduced chi-squared goodness-of-fit parameter greater than unity can be used to rescale the presumed under-estimation of the combined line-by-line variances , where are the type B variances due to spectral interferences. Therefore, we write
| (4) |
for , where is a smooth function of S which yields predicted values of σm,A(ST). The purpose of the smoothing functions is to minimize the influence of large deviations in σm,A(ST) that may arise from a low measurement sample size. The smoothing functions are plotted as solid lines in Fig. 5 and assume a linear relationship between σm,A(ST) and S.
The smoothing functions aim to extract an estimate of the type-A reproducibility only. As seen in Fig. 5, several values of σm,A(ST) appear to be outliers with relatively large short-term type-A uncertainties, especially for data set A (red squares). These outliers are attributed to the influence of spectral interferences (namely weak CO2 and H2O lines), and we excluded data points for transitions which have direct overlap with known H2O lines (R16 and R28). To avoid biasing , we weighted our fits of the smoothing functions by the normalized values . Consequently, transitions with the largest line-by-line type-B uncertainties attributed to spectral interferences were given a weight of zero and transitions uninfluenced by spectral interferences were given a weight of one. All other weights were linearly interpolated between the values of zero and one based on their relative systematic uncertainties .
5. Results and discussion
5.1. The 20013 ← 00001 integrated band intensity for 12C16O2
In this work, we measured the intensities of 39 unique CO2 transitions with lower state rotational quantum numbers of J′′ ≤ 44 using several tunable lasers near λ = 2.06 μm. With relatively broadband data, we were therefore able to determine an accurate integrated band intensity (Sband) for the 20013 ← 00001 band of . While the fitting of vibrational band parameters is commonly done when very broadband spectral data is available (e.g., with Fourier transform spectroscopy [29]), it is less common for laser diode spectroscopy because of the normally limited number of accessible transitions. Here we overcame the limitations of tunability in continuous-wave laser spectroscopy by brute force: first by aligning four DFB lasers and then again by the introduction of a narrow linewidth ECDL. The result was a tabulation of 63 intensity measurements of 39 transitions with relative combined standard uncertainties (ur,S) ranging from 0.13 % to 1.6 % (median value of ).
In this section, we apply and discuss two models for the individual intensities in order to determine Sband. In doing so, we show that the standard rotation-vibration coupling correction factor (i.e., the Herman-Wallis factor [30–33]) normally applied to the one-dimensional quantum mechanical model for S are not required when we instead compare directly with the J′′ dependence predicted by a fully ab initio dipole moment surface (DMS) [13]. For transitions with J′′ ≤ 44, we show that existing ab initio DMS calculations are as accurate as experiment in capturing the J′′ dependence of S for this combination-overtone band of a linear polyatomic molecule. Furthermore, subtle differences in the J′′ dependent models elude to secondary perturbations beyond rotation-vibration coupling which are captured by the ab initio DMS. We also show that Sband can be fitted equally well by either a properly normalized spectroscopic model or by applying a simple scaling of intensities from the ab initio DMS.
As introduced in Section 4, the proper choice of weighting factors for the band-wide fits is the inverse of the true type A variances associated with long-term reproducibility at each measurement point (i.e., each transition), [28]. However, line-by-line systematic contributions from spectral interferences have also been identified. Therefore, the chosen weighting factors are inversely proportional to the sum of type A (reproducibility) and type B (spectral interference, see Section 3) variances (e.g., ). Values of were estimated using Eq. (4) in Section 4, the smoothed functions plotted in Fig. 5, and the values of calculated from a fitted model. To simplify the weighted least-squares regressions, we chose to use the normalized weighting factors
| (5) |
Critically, the value of is not required to calculate the normalized weighting factors in Eq. (5), and only the smoothed functions plotted in Fig. 5 calculated from the observed short-term trends in fit precision and the systematic contributions from spectral interferences shown in Eq. (4) must be known a priori.
5.1.1. Standard spectroscopic model
The individual rotational-vibrational line intensities of a linear molecule can be calculated from the following spectroscopic model [34] with its origins in quantum mechanics [35]:
| (6) |
where SV is the vibrational band intensity without perturbation from rotation-vibration coupling, χiso is the reference isotopic abundance (e.g., χ626,HT), g is the degeneracy of the rotational-vibrational state, is the origin frequency of the vibrational band in cm−1, QR(T) is the rotational partition function, are the individual transition frequencies in cm−1, Lm are the Hönl-London factors, Fm are the Herman-Wallis factors, and are the lower state rotational energies in dimensions of wave number. For a more detailed discussion of Eq. (6) and its constituent terms, see Ref. [29].
For the 20013 ← 00001 12C16O2 band, we calculate from Section 4.1 of [29] that g = 1 and Lm = |m|, where m = −J′′ for the P-branch (ΔJ = J′ − J′′ = −1) and m = J′′ + 1 for the R-branch (ΔJ = +1), and J′ is the upper state rotational quantum number. For the form of the Herman-Wallis factor, we choose
| (7) |
where a1, a2, and a3 are fitted coefficients [along with SV in Eq. (6)]. In applying Eq. (6), the following terms were held constant: ν0 = 4854.447 cm−1 [13], T = Tref = 296 K, and QR(Tref) = 263.87063 [19, 27]. Values for χiso = χ626,HT, E′′ and ν were taken from HITRAN2016 [19].
We call attention here to the subtle difference between a vibrational band intensity (SV) and the integrated band intensity, [10]. If the Herman-Wallis factors in Eq. (6) are neglected (i.e., Fm = 1), then Sband = SV. However, once rotation-vibration coupling is introduced the values of SV and Sband diverge by consequence of their respective definitions. This is reconciled here by the introduction of F0, or the Herman-Wallis normalization factor, where Sband = F0SV.
The fitted values of a1, a2 and a3 are listed in Table 3, along with the normalization factor F0. Also listed is the isotopic-abundance-normalized integrated band intensity, . Following a first fitting iteration with F0 = 1, the normalization factor F0 was calculated imposing the constraint and subsequently fixed for a second and final fitting iteration. The full numerical normalization factor F0 is written in Eq. (8)
| (8) |
where the summation over m included 109 transitions with J′′ < 110, equal to the total number of 20013 ← 00001 12C16O2 transitions in HITRAN2016 [19].
Table 3.
Summary of the fitted 20013 ← 00001 12C16O2 vibrational band intensity parameters and reduced chi-squared values. Standard uncertainties are shown in parenthesis and represent the type A fit precisions retrieved from each model.
| Parameter | Units | Spectroscopic model | ab initio model |
|---|---|---|---|
| cm molecule−1 | 7.182(2)×10−21 | 7.1830(17)×10−21 | |
| a1 | 1.96(11)×10−4 | ||
| a2 | 2.98(3)×10−5 | ||
| a3 | 16(14)×10−8 | ||
| F0 | 1.0323 | ||
| 14.6 | 19.8 |
5.1.2. Application of an ab initio dipole moment surface
Intensities reported here for the 20013 ← 00001 12C16O2 band near λ = 2.06 μm were also compared to those available in the HITRAN2016 database [19], originally calculated by Zak et al. using an accurate ab initio DMS [13]. While the spectroscopic model discussed in the preceding Section 5.1.1 has its origins in quantum chemistry modeling, several basic assumptions are required to calculate the individual intensities using Eq. (6). As early evidence of its limitations, the Fm-style correction factors were introduced originally by Herman and Wallis [30] to account for perturbations to the rotational intensities due to rotation-vibration coupling. However, with a fully ab initio DMS available for CO2 and its isotopologues [13, 36, 37], we can simply forego the spectroscopic model and compare directly with intensities from the multidimensional ab initio DMS.
Plotted in Fig. 6 are the line-by-line values reported herein (SNIST) vs. the corresponding values in HITRAN2016 (SHT) [19] calculated from the ab initio DMS [13]. A weighted least-squares fit of the parameter β, where SNIST = βSHT, yielded the black line in Fig. 6 and the scaling parameter β = 1.0069 with a relative uncertainty of ur,β = 0.02 %. The integrated band intensity was then calculated using Eq. (9)
| (9) |
where the summation was again over 109 transitions with J′′ < 110. (We confirmed numerically that was equal to the integrated band intensity reported in Table 1 of [13].) Therefore, in addition to the spectroscopic model discussed in Section 5.1.1, we also report in Table 3 of this work a fitted value for which assumed a J′′ dependence from the ab initio DMS: cm molecule−1 .
Fig. 6.
Weighted regression of SNIST vs. SHT16 is shown in the top panel, where SNIST comprises both data sets A (red squares) and B (blue circles). The fitted scaling factor (solid black line) was β = 1.0069 ± 0.0002 (relative uncertainty of 0.02 %) — meaning that the NIST values for the 20013 ← 00001 12C16O2 band are 0.69 % larger than those tabulated in HITRAN2016 [19]. Relative fit residuals for both data sets A and B are plotted in the bottom panel. Error bars represent 1σ type A uncertainty in A296 vs. (see Table 4).
5.1.3. Reported line-by-line intensities
Here we report the line-by-line intensities measured in data sets A and B, as well as the intensities that resulted from weighted fits of the combined data sets to a spectroscopic model (Section 5.1.1) and an ab initio DMS (Section 5.1.2). The results are summarized in Table 4.
In Table 4, the values associated with the fitted β parameter (“ab initio model”) are all identical, with no m dependence in the scaling procedure. In contrast, the for the “spectroscopic model” have a noticeable m dependence caused by propagation of uncertainty in the fitted Fm coefficients comprising Eq. (7). Relative values of S calculated from both band fitting models are plotted vs. m in Fig. 7. In Fig. 7, the shaded area represents the uncertainty in this relative difference as a quadrature sum of s in Table 4 (both models). Small, systematic differences are observed when comparing the spectroscopic model and ab initio DMS model. However, the differences are on the order of the combined uncertainties plotted in Fig. 7.
Fig. 7.
Plotted vs. m is the relative difference between the spectroscopic model for intensities which included Herman-Wallis factors (SHW) and a scaled version of the ab initio DMS intensities (Sβ). The shaded region represents the quadrature sum of type-A fit precision from each model.
Given that the J′′ dependence of the ab initio DMS [as well as that of the underlying potential energy surface (PES)] should capture phenomena beyond just rotation-vibration coupling, we choose to report the β parameter scaling of the ab initio DMS as our experimentally derived values for SNIST: cm molecule−1 ± 6 × 10−24 cm molecule−1. The relative combined standard uncertainty (ur,S = 0.08 %) resulted from the quadrature sum of the type A fit precision from Section 5.1.2 shown in Table 4 of this section and the relative combined type B (systematic) standard uncertainty shown in Table 2 of Section 4. A final line list inclusive of our total measurement range is available as supplemental material. From , we calculate the vibrational band intensity of the 20013 ← 00001 CO2 band to be cm molecule−1 ± 6 × 10−24 cm molecule−1.
5.2. Final uncertainty evaluation
As detailed in Section 5.1.3, we report a line list for the 20013 ← 00001 band of 12C16O2 as a scaled version of the intensities calculated from the ab initio DMS of Zak et al. [13]. The scaling factor, β = 1.0069, leads to an integrated band intensity of 7.183 × 10−21 cm molecule−1 ± 6 × 10−24 cm molecule−1. Because the ab initio DMS intensities display a J′′ dependence which matches our experimental observations, we fit only the scaling factor β. Therefore, the relative combined uncertainties for all transitions reported in our line list are equal to the quadrature sum of the type A (fit precision on β) and type B (see Table 2) relative uncertainties, ur,S = 0.08 %. The consistency in ur,S vs. J′′ (or m, where m = −J′′ for the P-branch and m = J′′ + 1 for the R-branch) is a consequence of only fitting one parameter. All of our measured intensities weighted by the inverse of their combined variances contribute to the value of β. Therefore, scatter in these data about the ab initio model provides a measure of the long-term measurement reproducibility, whereas uncertainty in the weighted mean value of β affects the accuracy of the measured band intensity.
The line-by-line type A uncertainties reported in Table 4 for the spectroscopic model fit are very different and display a clear m dependence. This is not surprising and is a consequence of floating three Herman-Wallis coefficients (a1, a2, and a3) with their own levels of fit precision (and covariance). The values of reported for the spectroscopic model in Table 4, where is the type A standard uncertainty, were calculated using the full covariance matrix and Eq. (10),
| (10) |
Above, f represents the model in Eq. (6), xi are the floated parameters (quantity N = 4), σ2(xi) are the diagonal elements of the covariance matrix, and σ(xi, xj) are the off-diagonal elements (co-variances) [38]. Analytical expressions for the partial derivatives enabled accurate calculation from the estimated covariance matrix.
5.3. Constraining the Herman-Wallis expansion for CO2
For the nearby 20012 ← 00001 band of 12C16O2 at λ ≈ 2.0 μm, Casa et al. reported a constraint on the accuracy of the Herman-Wallis expansion of 0.5 % [39]. However, the constraint was limited by the number of intensity measurements reported within only the R-branch, up to m = 19. Further, subsequent measurements [14, 40, 41] and ab initio calculations [13] revealed systematic shifts in the original Casa et al. data attributed to the choice of line shape. Given the large number of intensities reported here, from m = −34 to m = 45, and our comprehensive, low uncertainty budget, we revisit the concept of constraining the accuracy of the Herman-Wallis expansion for CO2.
First, we note that the fitted values of retrieved from both the spectroscopic model and the ab initio model agreed to within their reported precisions of about 0.02 % to 0.03 % (see Table 3). While scales the line-by-line intensities [see Eq. (6)], we can further analyze the m-dependence of the spectroscopic model by focusing on just the Herman-Wallis expansion. Shown in Fig. 8 are the weighted residuals from the fitted spectroscopic model with 3rd-order Herman-Wallis expansion [see Eq. (7)], relative to the measured intensities. Using the weighted residuals, we calculate the root mean squared deviation from the weighted fit as:
| (11) |
where are again the normalized weights , Sm are the reported intensities measured here, and are the intensities fitted by the spectroscopic model. The result is a root mean squared deviation of , only a factor of 2.25 larger than our combined relative uncertainty of 0.08 %. Therefore, we postulate based on our experimental observations that the Herman-Wallis expansion can accurately reproduce the m-dependence of the 20013 ← 00001 band intensities to within .
Fig. 8.
Plotted vs. m are the weighted residuals from the fitted spectroscopic model, relative to the measured values of SNIST. Visual inspection of the weighted residuals suggests that the spectroscopic model with Herman-Wallis expansion is sufficient to capture m-dependent trends in the experimental data. The root mean squared deviation for the spectroscopic model with Herman-Wallis expansion is .
Our rigorous evaluation of the accuracy of the Herman-Wallis expansion is further strengthened by the availability of highly accurate ab initio calculations. The root mean squared deviation from the weighted fit to the ab initio model was similar, with a value of . Collectively, our observations and analysis comprise the most rigorous comparison of spectroscopic models, ab initio calculations, and low-uncertainty experiments for CO2 to date — fulfilling the relative uncertainty criteria of ≤0.1 % for reference line intensities required to achieve precision remote sensing of the Earth’s atmosphere. Furthermore, as enabled by our highly accurate FS-CRDS measurements, we explicitly show that CO2 intensities predicted by a fitted spectroscopic model with Herman-Wallis expansion are consistent with a simply rescaling of the integrated band intensity calculated by an ab initio dipole moment surface.
5.4. Comparisons with the literature: additional CO2 line lists
Figure 9 presents a comparison of our results with several databases and line lists available in the literature: intensities from HITRAN2012 [29, 42], Benner et al. [10], Ames-2016 [43], and the carbon dioxide spectroscopic databank, CDSD-296 [44] are plotted relative to our scaled ab initio model. The Fourier transform spectroscopy (FTS) line list of Benner et al. [10] has a J′′ dependence which is reproduced well by our data and by the ab initio DMS intensities over the range of J′′ ≤ 44. The Ames-2016 line list of Huang et al. [43], also an ab initio DMS calculation, displays a similar J′′ dependence. Significantly, the summary plot in Fig. 9 therefore shows good agreement between two independent experimental measurements (FS-CRDS and FTS) as well as two nearly independent theoretical approaches (University College London, UCL, and Ames-2016) on the J′′ dependence of the intensities within the 20013 ← 00001 12C16O2 vibrational band.
Fig. 9.
Comparison with reference databases. Plotted are relative differences Si/Sβ − 1 where Sβ = βSHT are the scaled ab initio DMS intensities [13]. The shaded region represents our relative combined standard uncertainty of 0.08 %. The relative standard uncertainties for each line list (not shown) are: HITRAN2012, 1 % [29, 42]; Benner 2016, 1 % [10]; Ames-2016, 1–3 % [43]; CDSD-296, 1.6 % [44].
The line lists, however, do disagree significantly in the magnitude of the integrated band intensity, . From the line lists we calculated the following average relative deviations from our scaled ab initio DMS line list: HITRAN2012: –0.52 % ± 0.15 %; Benner et al.: –1.16 % ± 0.05 %; Ames-2016: –0.54 % ± 0.18 %; CDSD-296: +0.33 % ± 0.20 %.
5.5. Comparisons with the literature: other measurements
Figure 10 shows an additional comparison of our scaled ab initio model with two publications from the CNRS group in Reims, France: a combined Fourier transform spectroscopy and tunable diode laser absorption spectroscopy (TDLAS) study by Régalia et al. [45], and 6 lines measured with laser diode absorption spectroscopy reported by Joly et al. [46]. The average agreement is quite good despite the large scatter found in the prior experiments. For the 2.06 μm band, Régalia et al. [45] performed multispectral fits using Voigt profiles to model absorption from single-pass sample cells containing high-purity CO2. In Joly et al. [46] several transitions were revisited again using TDLAS and Voigt profiles but with a multipass absorption cell. While, on average, agreement with the NIST values in Fig. 10 is good, Voigt profiles have been shown numerically to underestimate molecular line areas by 1 % to 4 % [47]. Therefore, the agreement may be partly coincidental.
Fig. 10.
Comparison with FTS [45] and laser diode absorption spectroscopy [46] measurements from CNRS. Plotted are relative differences Si/Sβ − 1 where Sβ = βSHT are the scaled ab initio DMS intensities [13]. The shaded region represents our relative combined standard uncertainty of 0.08 %. The relative combined standard uncertainty for the intensities in Ref. [45] (not shown) is about 2 %.
6. Conclusions
Here we report accurate frequency-stabilized cavity ring-down spectroscopy measurements of the 20013 ← 00001 vibrational band of 12C16O2 near λ = 2.06 μm. As one of the two CO2 bands observed by the NASA Orbiting Carbon Observatory-2, the so-called “strong band” at λ = 2.06 μm is important for space-based atmospheric measurements of carbon sources and sinks [48, 49] as well as various near-ground based regional observation platforms [50–52]. Our broadband measurements, performed using five different tunable continuous-wave lasers, were analyzed to yield fitted vibrational band intensities using two different models. Firstly, we fitted the measured values to the traditional spectroscopic model derived from fundamental assumptions of quantum mechanics, including Herman-Wallis factors with proper normalization. Secondly, we used our experimental values to scale the calculated ab initio intensities [13] found in HITRAN2016 [19]. This approach assumes that the ab initio dipole moment surface (DMS) of Zak et al. [13] accurately yields the J′′ dependence of the line-by-line intensities.
To reproduce the experimentally observed transition intensities, we find that the traditional spectroscopic model with the inclusion of three normalized Herman-Wallis factors, performed equally as well as a single-parameter scaling of the ab initio DMS values. However, given that the ab initio DMS is more physically general than the Herman-Wallis spectroscopic model and requires only a single floated parameter to fit to our measurements, we chose the results of Ref. [13] as the best available representation of the true CO2 DMS. To this end, we report an integrated band intensity for the 20013 ← 00001 vibrational band of 12C16O2 near λ = 2.06 μm of cm molecule−1 ± 6 × 10−24 cm molecule−1 (ur,S = 0.08 %). This experimental band intensity, used in combination with the J′′ dependence calculated from the ab initio DMS, allowed for a comparison of our accurate intensities with those available from other line lists and prior laser spectroscopy experiments.
Self-consistent and accurate line-by-line carbon dioxide reference data should encompass line intensities, line mixing coefficients and line shape parameters valid over a relevant range of temperature and pressure. These data are critical for further reduction of spectroscopic uncertainties in XCO2 retrieval error budgets [3]. Thompson et al. [53] improved 2.06 μm band retrievals through the addition of an ad hoc continuum, which is used in current ABSCO v5.0. The need for an ad hoc continuum could come from the nearest-neighbor line mixing approximation [10] used in ABSCO v5.0, which does not account for coupling between all combinations of lines, specifically between the P and R branches [54]. Also, given that line mixing involves intensities of the interacting lines, our reported values strongly constrain line-mixing models that are fit to measured spectra for this band. Future work will include band-wide laser scans and frequency-stabilized cavity ring-down spectroscopy measurements that probe a pressure range where line mixing and non-Voigt profile line shape effects are important. We seek to include the current study with these new measurements to yield a self-consistent set of reference data.
Acknowledgments
Funding: This work was supported by the National Institute of Standards and Technology (NIST); the NIST Greenhouse Gas and Climate Science Program; and the National Aeronautics and Space Administration (NASA) [contract number NRA NNH17ZDA001N-OCO2].
D. Michelle Bailey (NIST) provided comments on the manuscript.
Footnotes
Competing Interests
The authors declare no competing interests.
References
- 1.Feldman DR, Collins WD, Gero PJ, Torn MS, Mlawer EJ, Shippert TR. Observational determination of surface radiative forcing by CO2 from 2000 to 2010. Nature 2015;519:339. [DOI] [PubMed] [Google Scholar]
- 2.Intergovernmental Panel on Climate Change. Global Warming of 1.5°C, an IPCC special report on the impacts of global warming of 1.5°C above pre-industrial levels and related global greenhouse gas emission pathways, in the context of strengthening the global response to the threat of climate change, sustainable development, and efforts to eradicate poverty. Intergovernmental Panel on Climate Change; 2018. [Google Scholar]
- 3.Oyafuso F, Payne VH, Drouin BJ, Devi VM, Benner DC, Sung K, Yu S, Gordon IE, Kochanov R, Tan Y, et al. High accuracy absorption coefficients for the Orbiting Carbon Observatory-2 (OCO-2) mission: Validation of updated carbon dioxide cross-sections using atmospheric spectra. J Quant Spectrosc Radiat Transfer 2017;203:213–23. [Google Scholar]
- 4.Miller CE, Crisp D, DeCola PL, Olsen SC, Randerson JT, Michalak AM, Alkhaled A, Rayner P, Jacob J, Suntharalingam P, et al. Precision requirements for space-based data. Journal of Geophysical Research: Atmospheres. 2007;112:D10. [Google Scholar]
- 5.Fleisher AJ, Adkins EM, Reed ZD, Yi H, Long DA, Fleurbaey HM, Hodges JT. Twenty-five-fold reduction in measurement uncertainty for a molecular line intensity. Phys Rev Lett 2019;123:043001. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Cygan A, Wcisło P, Wójtewicz S, Kowzan G, Zaborowski M, Charczun D, Bielska K, Trawiński RS, Ciuryło R, Masłowski P, et al. High-accuracy and wide dynamic range frequency-based dispersion spectroscopy in an optical cavity. Opt Express 2019;27:21810–21821. [DOI] [PubMed] [Google Scholar]
- 7.Cygan A, Fleisher AJ, Ciuryło R, Gillis KA, Hodges JT, Lisak D. Cavity buildup dispersion spectroscopy, arXiv:2001.08447 [physics.optics]. [Google Scholar]
- 8.Long DA, Reed ZD, Fleisher AJ, Mendonca J, Roche S, Hodges JT. High accuracy near-infrared carbon dioxide intensity measurements to support remote sensing. Geophys Res Lett. doi: 10.1029/2019GL086344. [DOI] [Google Scholar]
- 9.Devi VM, Benner DC, Sung K, Brown LR, Crawford TJ, Miller CE, Drouin BJ, Payne VH, Yu S, Smith MAH, et al. Line parameters including temperature dependences of self- and air-broadened line shapes of 12C16O2: 1.6-μm region. J Quant Spectros Radiat Transfer 2016;177:117–44. [Google Scholar]
- 10.Benner DC, Devi VM, Sung K, Brown LR, Miller CE, Payne VH, Drouin BJ, Yu S, Crawford TJ, Mantz AW, et al. Line parameters including temperature dependences of air- and self-broadened line shapes of 12C16O2: 2.06-μm region. J Mol Spectrosc 2016;326:21–47. [Google Scholar]
- 11.Wunch D, Toon GC, Wennberg PO, Wofsy SC, Stephens RS, Fischer ML, Uchino O, Abshire JB, Bernauth P, Biraud SC, et al. Calibration of the Total Carbon Column Observing Network using aircraft profile data. Atmos Meas Tech 2010;3:1351–1362. [Google Scholar]
- 12.Polyansky OL, Bielska K, Ghysels M, Lodi L, Zobov NF, Hodges JT, Tennyson J. High-accuracy CO2 line intensities determined from theory and experiment. Phys Rev Lett 2015;114:243001. [DOI] [PubMed] [Google Scholar]
- 13.Zak E, Tennyson J, Polyansky OL, Lodi L, Zobov NF, Tashkun SA, Perevalov VI. A room temperature CO2 line list with ab initio computed intensities. J Quant Spectrosc Radiat Transfer 2016;177:31–42. [Google Scholar]
- 14.Yi H, Liu Q, Gameson L, Fleisher AJ, Hodges JT. High-accuracy 12C16O2 line intensities in the 2 μm wavelength region measured by frequency-stabilized cavity ring-down spectroscopy. J Quant Spectrosc Radiat Transfer 2018;206:367–77. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Yi H, Fleisher AJ. High-resolution cavity ring-down spectroscopy of the ν1 + ν6 combination band of methanol at 2.0 μm. J Chem Phys 2019;151:25146. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Truong G-W, Douglass KO, Maxwell SE, van Zee RD, Plusquellic DF, Hodges JT, Long DA. Frequency-agile, rapid scanning spectroscopy. Nat Photonics 2013;7:532–4. [Google Scholar]
- 17.Hodges JT, Layer HP, Miller WW, Scace GE. Frequency-stabilized single-mode cavity ring-down apparatus for high-resolution absorption spectroscopy. Rev Sci Instrum 2004;75:849–63. [Google Scholar]
- 18.Milton MJT, Guenther F, Miller WR, Brown AS. Validation of the gravimetric values and uncertainties of independently prepared primary standard gas mixtures. Metrologia 2006;43:L7–L10. [Google Scholar]
- 19.Gordon IE, Rothman LS, Hill C, Kochanov RV, Tan Y, Bernath PF, Birk M, Boudon V, Campargue A, Chance KV, et al. The HITRAN2016 molecular spectroscopic database. J Quant Spectrosc Radiat Transfer 2017;203:3–69. [Google Scholar]
- 20.Cancio P, Galli I, Bartalini S, Giusfredi G, Mazzotti D, De Natale P. Saturated-absorption cavity ring-down (SCAR) for high-sensitivity and high-resolution molecular spectroscopy in the mid IR In: Gagliardi G, Loock H-P, editors. Cavity-enhanced spectroscopy and sensing, Berlin: Springer-Verlag; 2014, p. 143–162. [Google Scholar]
- 21.Zhang J, Lu ZH, Wang LJ. Precision refractive index measurements of air, N2, O2, Ar, and CO2 with a frequency comb. Appl. Opt. 2008:47;3143–3151. [DOI] [PubMed] [Google Scholar]
- 22.Tennyson J, Bernath PF, Campargue A, Császár AG, Daumont L, Gamache RR, Hodges JT, Lisak D, Naumenko OV, Rothman LS, et al. Recommended isolated-line profile for representing high-resolution spectroscopic transitions (IUPAC Technical Report). Pure Appl Chem 2014;86:1931–43. [Google Scholar]
- 23.Lance B, Blanquet G, Walrand J, Bouanich J. On the speed-dependent hard collision lineshape models: Application to C2H2 perturbed by Xe. J Mol Spectrosc 1997;185:262–71. [DOI] [PubMed] [Google Scholar]
- 24.Lisak D, Cygan A, Wcisło P, Ciuryło R. Quadratic speed dependence of collisional broadening and shifting for atmospheric applications. J Quant Spectrosc Radiat Transfer 2015;151:43–8. [Google Scholar]
- 25.Ghysels M, Liu Q, Fleisher AJ, Hodges JT. A variable-temperature cavity ring-down spectrometer with applications to the line shape analysis of CO2 spectra in the 1600 nm region. Appl Phys B 2017;123:124. [Google Scholar]
- 26.Galatry L Simultaneous effect of Doppler and foreign gas broadening on spectral lines. Phys Rev 1961;122:1218–23. [Google Scholar]
- 27.Gamache RR, Roller C, Lopes E, Gordon IE, Rothman LS, Polyansky OL, Zobov NF, Kyuberis AA, Tennyson J, Yurchenko SN, et al. Total internal partition sums for 166 isotopologues of 51 molecules important in planetary atmospheres: Application to HITRAN2016 and beyond. J Quant Spectrosc Radiat Transfer 2017;203:70–87. [Google Scholar]
- 28.The procedure presented in Section 4 uses information in the NIST Engineering Statistics Handbook, specifically sections 1.3.5.15. Chi-Square Goodness-of-Fit Test, 4.1.4.3. Weighted Least Squares Regression, and 4.4.5.2. Accounting for Non-Constant Variation Across the Data: cited as NIST/SEMATECH e-Handbook of Statistical Methods, https://www.itl.nist.gov/div898/handbook/, accessed 21 January 2020. [Google Scholar]
- 29.Toth RA, Brown LR, Miller CE, Devi VM, Benner DC. Line strengths of 12C16O2: 4500–7000 cm−1. J Mol Spectrosc 2006;239:221–42. [Google Scholar]
- 30.Herman R, Wallis RF. Influence of vibration-rotation interaction on line intensities in vibration-rotation bands of diatomic molecules. J Chem Phys 1955;23:637–46. [Google Scholar]
- 31.Toth RA. Line intensities of N2O in the 1120–1440 cm−1 region. Appl Opt 1984;23:1825–34. [DOI] [PubMed] [Google Scholar]
- 32.Johns JWC. Absolute intensity and pressure broadening measurements of CO2 in the 4.3 μm region. J Mol Spectrosc 1987;125:442–64. [Google Scholar]
- 33.Watson JKG. Quadratic Herman-Wallis factors in the fundamental bands of linear molecules. J Mol Spectrosc 1987;125:438–41. [Google Scholar]
- 34.Rothman LS, Young LDG. Infrared energy levels and intensities of carbon dioxide—II. J Quant Spectrosc Radiat Transfer 1981;25:505–24. [Google Scholar]
- 35.Bunker PR, Jensen Per. Molecular Symmetry and Spectroscopy, 2nd ed. Ottawa: NRC Research Press; 2006. [Google Scholar]
- 36.Zak EJ, Tennyson J, Polyansky OL, Lodi L, Zobov NF, Tashkun SA, Perevalov VI. Room temperature line lists for CO2 symmetric isotopologues with ab initio computed intensities. J Quant Spectrosc Radiat Transfer 2017;189:267–80. [Google Scholar]
- 37.Zak EJ, Tennyson J, Polyansky OL, Lodi L, Zobov NF, Tashkun SA, Perevalov VI. Room temperature line lists for CO2 asymmetric isotopologues with ab initio computed intensities. J Quant Spectrosc Radiat Transfer 2017;203:265–81. [Google Scholar]
- 38.Taylor BN, Kuyatt CE. Guidelines for evaluating and expressing the uncertainty of NIST measurement results. NIST Technical note 1297 1994. [Google Scholar]
- 39.Casa G, Parretta DA, Castrillo A, Wehr R, Gianfrani L. Highly accurate determinations of CO2 line strengths using intensity-stabilized diode laser absorption spectrometry. J. Chem. Phys. 2007:127;084311. [DOI] [PubMed] [Google Scholar]
- 40.Wübbeler G, Padilla Viquez GJ, Jousten K, Werhahn O, Elster C. Comparison and assessment of procedures for calculating the R(12) line strength of the ν1 + 2ν2 + ν3 band of CO2. J Chem Phys 2011:135;204304. [DOI] [PubMed] [Google Scholar]
- 41.Odintsova TA, Fasci E, Moretti L, Zak EJ, Polyansky OL, Tennyson J, Gianfrani L, Castrillo A. Highly accurate intensity factors of pure CO2 lines near 2 μm. J Chem. Phys. 2017:146;244309. [DOI] [PubMed] [Google Scholar]
- 42.Rothman LS, Gordon IE, Babikov Y, Barbe A, Benner DC, Bernath PF, Birk M, Bizzocchi L, Boudon V, Brown LR, et al. The HITRAN2012 molecular spectroscopic database. J Quant Spectrosc Radiat Transfer 2013;130:4–50. [Google Scholar]
- 43.Huang X, Schwenke DW, Freedman RS, Lee TJ. Ames-2016 line lists for 13 isotopologues of CO2: Updates, consistency, and remaining issues. J Quant Spectrosc Radiat Transfer 2017:203;224–41. [Google Scholar]
- 44.Tashkun SA, Perevalov VI, Gamache RR, Lamouroux J. CDSD-296, high resolution carbon dioxide spectroscopic databank: An update. J Quant Spectrosc Radiat Transfer 2019;228;124–131. [Google Scholar]
- 45.Régalia-Jarlot L, Zéninari V, Parvitte B, Grossel A, Thomas X, von der Heyden P, Durry G. A complete study of the line intensities of four bands of CO2 around 1.6 and 2.0 μm: A comparison between Fourier transform and diode laser measurements. J Quant Spectrosc Radiat Transfer 2006;101:325–38. [Google Scholar]
- 46.Joly L, Marnas F, Gibert F, Bruneau D, Grouiez B, Flamant PH, Durry G, Dumelie N, Parvitte B, Zéninari V. Laser diode absorption spectroscopy for accurate CO2 line parameters at 2.0 μm: Consequences for space-based DIAL measurements and potential biases. Appl Opt 2009;48:5475–83. [DOI] [PubMed] [Google Scholar]
- 47.Kochanov VP. On systematic errors in spectral line parameters retrieved with the Voigt line profile. J. Quant. Spectrosc. Radiat. Transfer 2012;113:1635–41. [Google Scholar]
- 48.Crisp D, Atlas RM, Breon F-M, Brown LR, Burrows JP, Ciais P, Conner BJ, Doney SC, Fung IY, Jacob DJ, et al. The Orbiting Carbon Observatory (OCO) mission. Adv Space Res 2004;34:700–9. [Google Scholar]
- 49.Yang Z, Toon GC, Margolis JS, Wennberg PO. Atmospheric CO2 retrieved from ground-based near IR solar spectra. Geophys Res Lett 2002;29:53. [Google Scholar]
- 50.Washenfelder RA, Toon GC, Blavier J-F, Yang Z, Allen NT, Wennberg PO, Vay SA, Matross DM, Daube BC. Carbon dioxide column abundances at the Wisconsin Tall Tower site. J Geophys Res Atmos 2006;111:D22305. [Google Scholar]
- 51.Rieker GB, Giorgetta FR, Swann WC, Kofler J, Zolot AM, Sinclair LC, Baumann E, Cromer C, Petron G, Sweeney C, et al. Frequency-comb-based remote sensing of greenhouse gases over kilometer air paths. Optica 2014;1:290–8. [Google Scholar]
- 52.Cossel KC, Waxman EM, Giorgetta FR, Cermak M, Coddington IR, Hesselius D, Ruben S, Swann WC, Truong G-W, Rieker GB, et al. Open-path dual-comb spectroscopy to an airborne retroreflector. Optica 2017;4:724–8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 53.Thompson DR, Benner DC, Brown LR, Crisp D, Devi VM, Jiang Y, Natraj V, Oyafuso F, Sung K, Wunch D, et al. Atmospheric validation of high accuracy CO2 absorption coefficients for the OCO-2 mission. J Quant Spectrosc Radiat Transfer 2012;113:2265–2276. [Google Scholar]
- 54.Lamouroux J, Régalia L, Thomas X, Vander Auwera J, Gamache RR, Hartmann JM. CO2 line-mixing database and software update and its tests in the 2.1 μm and 4.3 μm regions. J Quant Spectrosc Radiat Transfer 2015;151:88–96. [Google Scholar]










