Skip to main content
Acta Orthopaedica et Traumatologica Turcica logoLink to Acta Orthopaedica et Traumatologica Turcica
. 2020 May;54(3):330–336. doi: 10.5152/j.aott.2020.03.156

Comparison of peripheral nerve repair using ethyl-cyanoacrylate and conventional suture technique in a rat sciatic nerve injury model

Camettin Atam 1, Zafer Orhan 2, Gaye Toplu 3, Merdan Serin 3,, Z Okan Karaduman 2, Ayhan Öztürk 4
PMCID: PMC7586772  PMID: 32544069

Abstract

Objective

The aim of this study was to compare the outcomes of primary nerve repair using either ethyl-cyanoacrylate or conventional microsuture technique in a rat peripheral nerve injury model.

Methods

In this study, a total of 30 Wistar Albino rats weighing between 220 and 275g were used. The rats were randomly divided into three groups (10 in each), including one control (group 1) and two experimental groups (group 2, conventional microsuture repair; group 3, cyanoacrylate repair). In each group, the sciatic nerve was identified and transected. No further intervention was performed in group 1. The nerve was repaired using the epineural technique with a 10/0 atraumatic nylon in group 2 and synthetic cyanoacrylate adhesive in group 3. At the fifth postoperative week, needle electromyography (EMG) was performed to measure distal latency, combined muscle action potential (CMAP), and motor nerve conduction velocity (MNCV). Following the EMG recordings, animals were euthanized. Nerve samples were collected to evaluate vacuolar degeneration, fibrosis, and foreign body reaction histopathologically.

Results

In the EMG analysis, mean distal latency was significantly shorter in group 1 (0.85±0.09 ms) than in groups 2 (1.17±0.25 ms) (p=0.0052) and 3 (1.14±0.14 ms) (p=0.0026) while no significant differences existed between groups 2 and 3 (p>0.9999). The mean CMAP was greater in group 1 (10.5±0.35 mV) than in groups 2 (2.86±1.28 mV) (p=0.011) and 3 (2.16±1.34 mV) (p=0.0002), but there was no significant difference between groups 2 and 3 (p>0.9999). The mean MNCV was 53.5±5.95, 39.62±7.31, and 39.84±4.73 mm/sec in groups 1, 2, and 3, respectively. There was a significant difference between groups 1 and 2 (p=0.0052) and between 1 and 3 (p=0.0026), but not between 2 and 3 (p>0.9999). In the histopathological evaluation, the mean vacuolar degeneration score was 0, 2.12, and 1.88 in groups 1, 2, and 3, respectively. No obvious difference was observed between groups 2 and 3 (p=0.743). The mean fibrosis score was 0, 1.62, and 1.77 in groups 1, 2, and 3, respectively. There was no significant difference between groups 2 and 3 (p=0.888). The mean foreign body reaction score was 0, 2.5, and 2.44 in groups 1, 2, and 3, respectively. No difference was present between groups 2 and 3 (p=0.743).

Conclusion

Primary nerve repair using the cyanoacrylate adhesive may provide similar electrophysiological and histopathological results as compared to the conventional microsuture repair.

Keywords: Rat, Cyanoacrylate, Peripheral nerve injury, Peripheral nerve repair


Peripheral nerve injuries are a leading cause of permanent disability. These injuries are frequently a result of work and traffic accidents and primarily affect the young population and are frequently accompanied by other musculoskeletal injuries (1).

The classical treatment of complete dissection of a peripheral nerve involves perineural or epineural coaptation with microsutures. Despite being the preferred technique, this is a time-consuming procedure and misplaced sutures can potentially impair blood flow to axons thereby interrupting nerve regeneration (2).

Various alternative techniques have been proposed for nerve repair, including adhesive techniques that involve application of an adhesive material to both ends of the transected nerve for coaptation (36). An ideal adhesive should be easy to apply, have high binding strength, and be compatible with the surrounding tissue. Fibrin glue has been used as an adhesive for nerve repair and for microvascular anastomosis (7, 8). It is most often used in combination with nylon sutures since alone it does not have sufficient strength to hold the anastomosis in place. The major advantage of fibrin glue over other adhesives is its biocompatibility. However, since it is a blood product, it carries the risk of blood-borne disease transmission.

Alternatively, previous studies have proposed cyanoacrylate glue as an adhesive for microvascular anastomosis and nerve injuries (9, 10). Experimental studies on rats found no difference with respect to recovery of the peripheral nerve between nerve repair using synthetic cyanoacrylate adhesive and repair using microsutures, but most of these studies relied on histological evaluation of the results, which could be misleading or incomplete in the absence of an electrophysiological study (1013).

The aim of this study was to compare the use of cyanoacrylate adhesive with conventional microsuturing in primary nerve repair using electrophysiology and histological analysis.

Materials and Methods

The study was conducted in Düzce University Medical School Animal Research Laboratory with the approval of the local ethics committee of Düzce University (Protocol number: 2010–01). Thirty Wistar albino rats weighing between 220 and 275 g were used. Ten animals were selected randomly for each group.

Rats were anesthetized with an intraperitoneal injection of 5 mg/kg xylazine hydrochloride and 75 mg/kg ketamine. Cefazolin was used as a prophylactic antibiotic. The skin was shaved prior to surgery and prepared with povidone-iodine solution.

A longitudinal incision was performed on the anterior thigh and hip to visualize the thigh muscles. The muscles were split to gain access to the sciatic nerve, which was dissected free from the surrounding tissues, and the tibial and peroneal branches were dissected away from each other. The rats were divided into one control and two experimental groups:

  • Group 1 (control): The nerve was transected (Figure 1) approximately 15 mm proximal to the sural, peroneal, and tibial nerve trifurcation using microscissors (Figure 2). No further intervention was made in this group.

  • Group 2 (conventional microsuture repair): The transected nerve was repaired under an operating microscope with 10/0 atraumatic nylon sutures. The epineural technique was used for the repair and approximately four sutures were placed for each repair (Figure 3).

  • Group 3 (cyanoacrylate repair): The proximal and distal ends of the nerve were held in place temporarily with a single 10/0 nylon suture while ethyl cyanoacrylate (Permabond, Permabond Engineering Adhesives Ltd., Hampshire, UK) was applied to both ends of the nerve to complete the repair (Figure 4). The suture was immediately removed following the application of the adhesive material.

Figure 1.

Figure 1

The left sciatic nerve is reached by separation of the femoral muscle through a longitudinal incision on the anterior aspect of the left hip and thigh with the rat in a supine position

Figure 2.

Figure 2

The sciatic nerve is cut sharply and transversely using microscissors at a point 15 mm proximal to the trifurcation of the sural, peroneal, and tibial nerves

Figure 3.

Figure 3

The nerve in the conventional-suture group is repaired by end-to-end coaptation using four stitches of 10/0 atraumatic nylon suture material

Figure 4.

Figure 4

The nerve in the cyanoacrylate group is repaired with a single 10/0 monofilament nylon suture and application of 0.2 ml cyanoacrylate adhesive to the proximal and distal ends of the nerve

Muscle repair and closure of the skin incision was performed in all groups with 5/0 nylon sutures at the end of surgery. Analgesia was administered following the surgery. Results were evaluated at the fifth postoperative week using macroscopic, electrophysiological, and histological examinations.

Electrophysiological evaluation

Needle electromyography (EMG) evaluation was performed by a neurologist who was blinded to the experimental groups. An Esaote Myto II EMG (Esaote, Istanbul, Turkey) device was used for the evaluation. Room temperature was kept at 24–25 °C for the evaluation. Rats were anesthetized using an intraperitoneal injection of 75 mg/kg ketamine (Ketalar, Pfizer, New York, USA). The electrical stimulus was given 2 cm proximal to the repair site of the nerve. Bipolar needle electrodes placed 2.5 cm distal to the repair site were used as a detector. Combined muscle action potentials (CMAPs) were recorded. Maximum CMAP amplitude, latency (the time delay between stimulation and CMAP onset), and motor nerve conduction velocity (MNCV) were calculated. In healthy resting muscles, two types of electrical activity can be recorded. The first occurs with movement of the needle inside the muscle. The second is due to the muscle end plate potential, which can be a low-amplitude electronegative activity (endplate noise) or can be composed of spikes (endplate spikes). During muscle contraction, motor-unit action potentials are recorded. A decrease in the amplitude and duration of the spikes and abnormal electrical activity at rest are usually indicative of a pathological condition. The distal latency difference is the interval measured from the moment of stimulation of the distal-most accessible site on the nerve. For MNCV calculation, the conduction distance between the stimulating electrodes and the latency of CMAP is measured. To calculate the MNCV, the proximal latency is subtracted from the distal latency and divided by the conduction distance.

Histological evaluation

Following the EMG study, the rats were euthanized using a lethal-dose intraperitoneal phenobarbital injection and nerve samples for histopathological examination were obtained. Samples were fixed in 10% formaldehyde solution, embedded in paraffin, and 3–4 μ slices were obtained. H&E, Toluidine Blue, and Masson’s Trichrome stainings were performed. An Olympus BX50 (Tokyo, Japan) microscope was used to evaluate the samples. Parameters including vacuolar degeneration, fibrosis, and foreign-body reaction were evaluated (Figure 5). Vacuolar degeneration characterized by the presence of cytoplasmic vacuoles and fibrosis is consistent with degeneration following nerve injury. For the foreign-body reaction score and inflammatory response, the presence of activated macrophages, foreign-body giant cells in the epineural space, and morphometric changes were evaluated.

Figure 5. a–h.

Figure 5. a–h

Photomicrographs from histological evaluations. a. Normal findings in a longitudinal nerve section (control group) (toluidine blue (TB) x400). b. Normal findings in a longitudinal nerve section (control group) (Masson’s trichrome (MT) x400). c. Vacuolar degeneration in the cytoplasm of nerve cells accompanied by proliferation (conventional-suture group) (TBx400). d. Vacuolar degeneration in the cytoplasm of nerve cells accompanied by proliferation (cyanoacrylate group) (TBx400). e. Foreign-body reaction with inflammatory-cell infiltration, fibroblastic-vascular cell proliferation and giant cells (conventional-suture group) (TBx100). f. Foreign-body reaction with inflammatory cell infiltration (cyanoacrylate group) (TBx100). g. Significant fibrosis areas near the nerve cell (conventional-suture group) (MTx200). h. Significant fibrosis areas near the nerve cell (cyanoacrylate group) (MTx200) (Blue-stained areas near the nerve cell indicate fibrosis)

Statistical analysis

Statistical evaluation was performed to establish a descriptive and comparative analysis of the results. The Kruskal-Wallis test and Mann-Whitney U tests were used to compare the groups. Multiple comparisons were performed using Dunn’s test.

Results

Distal latency difference, action potential amplitude, and MNCV results

Mean distal latency difference values in milliseconds were 0.85±0.09, 1.17±0.25, and 1.14±0.14 for the control, conventional suture, and cyanoacrylate groups respectively (p values: control vs conventional: 0.0052 control vs cyanoacrylate: 0.0026 conventional vs cyanoacrylate: >0.9999). Mean action potential amplitudes in millivolts were 2.86±1.28, 2.16±1.34, and 10.5±0.35 for the control, conventional suture, and cyanoacrylate groups respectively (p values: control vs conventional: 0.0110, control vs cyanoacrylate: 0.0002, conventional vs cyanoacrylate: >0.9999). Mean MNCV values in millimeters per second were 53.5±5.95, 39.62±7.31, and 39.84±4.73 for the control, suture, and cyanoacrylate groups, respectively (p values: control vs conventional: 0.0052, control vs cyanoacrylate: 0.0026, conventional vs cyanoacrylate: >0.9999). The differences between the conventional suture and cyanoacrylate groups were statistically insignificant. Differences between the conventional suture group and the control group and between the cyanoacrylate group and the control group were all statistically significant (Figure 6).

Figure 6. a–f.

Figure 6. a–f

Summary of electrophysiological and histological findings. a. Mean distal latency difference measurements in milliseconds. b. Mean combined muscle action potential (CMAP) amplitude in millivolts. c. Mean motor nerve conduction velocity (MNCV) values in millimeters per second. d. Mean vacuolar degeneration scores in each group. e. Mean foreign-body-reaction scores in each group. f. Mean fibrosis scores in each group (*p <0.05)

Vacuolar degeneration, fibrosis and foreign-body-reaction results

The mean numbers of vacuolar degeneration scores were 0, 2.12, and 1.88 for the control, suture, and cyanoacrylate groups, respectively (p value: conventional vs cyanoacrylate: 0.606). The mean numbers of fibrosis scores were 0, 1.62, and 1.77 for the control, suture, and cyanoacrylate groups, respectively (p value: conventional vs cyanoacrylate: 0.888). The mean numbers of foreign-body-reaction scores were 0, 2.5, and 2.44 for the control, suture, and cyanoacrylate groups, respectively (p values: conventional vs cyanoacrylate: 0.743). The differences between the conventional suture and cyanoacrylate groups were statistically insignificant. The differences between the conventional suture group and the control group and between the cyanoacrylate group and the control group were statistically significant (p <0.05) (Figure 6).

Discussion

Peripheral nerve injuries that can result in long-term functional impairment are common in clinical practice. Despite ongoing experimental and clinical research, nerve regeneration results are often incomplete and can result in permanent disabilities. The rat sciatic nerve model is commonly used in experimental research. Advantages of this nerve-injury model include the fact that the sciatic nerve is a mixed sensory and motor nerve and that this model is cost effective (14).

Human peripheral nerve axons have a high regeneration capacity after trauma (15). Despite this, various problems after nerve repair can result in impaired nerve regeneration. The outcome of nerve regeneration depends on the balance between Schwann cell nerve regeneration and scar tissue (16). Excessive scar tissue can be related to technical difficulties regarding nerve coaptation during surgery. In our study, we found that the fibrosis scores of the conventional suture and cyanoacrylate repair groups were similar. Despite these results, the lack of skill of inexperienced surgeons in performing conventional-suture repair is probably more likely to result in scar formation. Cyanoacrylate repair could therefore be advantageous for surgeons who are inexperienced in microsurgical procedures.

Electrophysiological studies are one of the most valuable tools to evaluate recovery following peripheral nerve injury. Despite this, early EMG studies cannot provide sufficient information since axons are still regenerating in the early postoperative period (17). In our study, we allowed five weeks of regeneration to ensure that the electrophysiological study was reliable. The electrophysiological results revealed no significant difference in the CMAP amplitude, MNCV values, or distal latency times of the cyanoacrylate and conventional suture groups. Regeneration after a nerve injury can be assessed based on the number of axons and the nerve diameter, but these histological parameters are often insufficient to determine the quality and functional status of the axons (18). Some axons may be disrupted and dysfunctional (17, 19). Electrophysiological studies that provide combined action potential information are valuable in this respect (20). A delay in surgery after nerve injury is an important factor that affects functional outcomes. In our study, immediate nerve repair was performed. In clinical settings, possible delays in repair might correspond to differences in results (2123). One of the shortcomings of combined-action-potential measurement is that the results are dominated by the nerve fascicles that are myelinated and fast. Amplitude and speed measurements do not correspond to the whole nerve but rather to the fastest, most myelinated fascicles (24). Electrophysiological study results also correlate with the numbers and diameters of axons and the numbers of dorsal root ganglion cells. One of the limitations of this study was that it lacked tests to evaluate the functionality of the rats, such as walking. Future studies involving further histology and electron microscopy could be valuable to demonstrate nerve regeneration and the efficiency of nerve repair using adhesives.

Synthetic tissue adhesives have been used previously in studies of vessel anastomosis and nerve repair. Cyanoacrylates are synthetic adhesives that react quickly with biological tissues when in contact with air, water, or blood. Their toxicity depends on the rate of elimination. Formaldehyde and heat are produced once they are in contact with air, which are responsible for their toxicity (25). Short-chain acrylate adhesives such as ethyl-2-cyanoacrylate have higher tissue toxicity (26, 27). Long-chain acrylates such as 2-octyl-cyanoacrylate have proven to be much less toxic in comparison and have been approved for topical use by the FDA (28). Hall et al. and Ang et al. used octyl cyanoacrylate for microsurgical vessel anastomosis with success (29, 30). At three weeks post-surgery, they found that there was no foreign-body reaction and excess adhesive had been completely resorbed from surrounding tissues. However, ethyl-cyanoacrylate repair has been shown to induce Wallerian degeneration, macrophage density, and an inflammatory reaction that can increase the regeneration capacity of the nerve (9). In a previous study that used a pig model, Rickett et al. found no acute toxicity from ethyl cyanoacrylate, and the bonding strength was sufficient for nerve repair (31). In our study, histological examination revealed no significant difference in foreign-body-reaction findings between the conventional suture and cyanoacrylate groups.

Microsuture anastomosis is the conventional technique used in nerve repairs. This technique has the potential to disrupt the fascicular blood flow and delay nerve regeneration and tissue repair, especially in the hands of surgeons inexperienced in microsurgery. The skills needed for cyanoacrylate repair, in contrary, are easy to learn and have a shallow learning curve. Cyanoacrylate nerve repair can be performed in tight spaces such as the intraoral region where conventional repair would be very difficult.

In conclusion, in our study, there were no significant differences between the conventional suture and cyanoacrylate techniques in terms of CMAP peak amplitude, distal latency, and MNCV measurements. In addition, the histological findings of the two groups regarding vacuolar degeneration, fibrosis, and foreign-body reactions were similar. Nerve separation was not seen in any of the repairs using cyanoacrylate, indicating the adequate adhesive strength of the material. In conclusion, our results imply that cyanoacrylate nerve repair can achieve similar results to conventional suture techniques in certain situations. The cyanoacrylate technique is inexpensive, less time consuming, and easy to learn. It can be used safely in inconvenient and tight surgical spaces with basic microsurgical training.

HIGHLIGHTS.

  • Ethyl-cyanoacrylate and conventional microsuture technique in a rat peripheral nerve injury model revealed similar needle electromyography (EMG) results at the fifth postoperative week.

  • Ethyl-cyanoacrylate and conventional microsuture groups showed similar reaction histopathological findings at the fifth postoperative week.

  • Primary nerve repair using the cyanoacrylate adhesive yielded comparable results with the conventional microsuture repair.

Footnotes

Ethics Committee Approval: Ethics committee approval was received for this study from the Local Ethics Committee of Düzce University (Protocol number: 2010-01).

Author Contributions: Concept - C.A, Z.O., Z.O.K.; Design - C.A, Z.O., Z.O.K.; Supervision - Z.O.; Resources - C.A, Z.O., G.T., Z.O.K.; Materials - C.A, Z.O., G.T., Z.O.K.; Data Collection and/or Processing - C.A, Z.O, M.S, Z.O.K.; Analysis and/or Interpretation - C.A, Z.O, M.S, Z.O.K., A.O.; Literature Search - G.T, M.S., Z.O.K.; Writing Manuscript - M.S, Z.O.K.; Critical Review - Z.O., A.O.

Conflict of Interest: The authors have no conflicts of interest to declare.

Financial Disclosure: The authors declared that this study has received no financial support.

References

  • 1.Ciaramitaro P, Mondelli M, Logullo F, et al. Traumatic peripheral nerve injuries: epidemiological findings, neuropathic pain and quality of life in 158 patients. J Peripher Nerv Syst. 2010;15:120–7. doi: 10.1111/j.1529-8027.2010.00260.x. [DOI] [PubMed] [Google Scholar]
  • 2.Levinthal R, Brown WJ, Rand RW. Comparison of fascicular, interfascicular and epineural suture techniques in the repair of simple nerve lacerations. J Neurosurg. 1977;47:744–50. doi: 10.3171/jns.1977.47.5.0744. [DOI] [PubMed] [Google Scholar]
  • 3.Roth J, Shtokman J, Shamir MH, et al. Regeneration of the transected rat sciatic nerve after suturing or adhesion with cyanoacrylate glue. J Neurosurg. 2011;114:245–52. doi: 10.3171/2010.7.JNS091266. [DOI] [PubMed] [Google Scholar]
  • 4.Papalia I, Magaudda L, Righi M, et al. Epineurial window is more efficient in attracting axons than simple coaptation in a sutureless (cyanoacrylate-bound) model of end-to-side nerve repair in the rat upper limb: functional and morphometric evidences and review of the literature. PLoS One. 2016;11:e0148443. doi: 10.1371/journal.pone.0148443. doi: 10.1371/journal.pone.0148443. eCollection 2016. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Liu ZY, Chen ZB, Chen JH. A novel chronic nerve compression model in the rat. Neural Regen Res. 2018;13:1477–85. doi: 10.4103/1673-5374.235306. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Zhang ZY, Yang J, Fan ZH, et al. Fresh human amniotic membrane effectively promotes the repair of injured common peroneal nerve. Neural Regen Res. 2019;14:2199–208. doi: 10.4103/1673-5374.262596. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Nishihira S. Experimental study of motor nerve repair: comparison of nylon suture and two component fibrin adhesive techniques. Nihon Jibiinkoka Gakkai Kaiho. 1988;91:1208–12. doi: 10.3950/jibiinkoka.91.1208. [DOI] [PubMed] [Google Scholar]
  • 8.Nishihira S, McCaffrey TV. Repair of motor nerve defects: comparison of suture and fibrin adhesive techniques. Otolaryngol Head Neck Surg. 1989;100:17–21. doi: 10.1177/019459988910000103. [DOI] [PubMed] [Google Scholar]
  • 9.Landegren T, Risling M, Persson JK. Local tissue reactions after nerve repair with ethyl-cyanoacrylate compared with epineural sutures. Scand J Plast Reconstr Surg Hand Surg. 2007;41:217–27. doi: 10.1080/02844310701552001. [DOI] [PubMed] [Google Scholar]
  • 10.Souther SG, Levitsky S, Roberts WC. Bucrylate tissue adhesive for microvascular anastomosis. Technique, results, and histologic evaluation. Arch Surg. 1971;103:496–9. doi: 10.1001/archsurg.1971.01350100094017. [DOI] [PubMed] [Google Scholar]
  • 11.Choi BH, Kim BY, Huh JY, et al. Microneural anastomosis using cyanoacrylate adhesives. Int J Oral Maxillofac Surg. 2004;33:777–80. doi: 10.1016/j.ijom.2004.03.006. [DOI] [PubMed] [Google Scholar]
  • 12.Landegren T, Risling M, Brage A, Persson JK. Long-term results of peripheral nerve repair: a comparison of nerve anastomosis with ethyl-cyanoacrylate and epineural sutures. Scand J Plast Reconstr Surg Hand Surg. 2006;40:65–72. doi: 10.1080/02844310500513030. [DOI] [PubMed] [Google Scholar]
  • 13.Pineros-Fernandez A, Rodeheaver PF, Rodeheaver GT. Octyl 2-cyanoacrylate for repair of peripheral nerve. Ann Plast Surg. 2005;55:188–95. doi: 10.1097/01.sap.0000164386.72523.3c. [DOI] [PubMed] [Google Scholar]
  • 14.West CA, Davies KA, Hart AM, Wiberg M, Williams SR, Terenghi G. Volumetric magnetic resonance imaging of dorsal root ganglia for the objective quantitative assessment of neuron death after peripheral nerve injury. Exp Neurol. 2007;203:22–33. doi: 10.1016/j.expneurol.2006.07.013. [DOI] [PubMed] [Google Scholar]
  • 15.Tatagiba M, Rosahl S, Gharabaghi A, et al. Regeneration of auditory nerve following complete sectioning sectioning and intrathecal application of the IN-1 antibody. Acta Neurochir (Wien) 2002;144:181–7. doi: 10.1007/s007010200022. [DOI] [PubMed] [Google Scholar]
  • 16.Sullivan R, Dailey T, Duncan K, Abel N, Borlongan CV. Peripheral nerve injury: Stem cell therapy and peripheral nerve transfer. Int J Mol Sci. 2016;17 doi: 10.3390/ijms17122101. pii: E2101. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Nichols CM, Myckatyn TM, Rickman SR, Fox IK, Hadlock T, Mackinnon SE. Choosing the correct functional assay: a comprehensive assessment of functional tests in the rat. Behav Brain Res. 2005;163:143–58. doi: 10.1016/j.bbr.2005.05.003. [DOI] [PubMed] [Google Scholar]
  • 18.Terenghi G, Calder JS, Birch R, Hall SM. A morphological study of Schwann cells and axonal regeneration in chronically transected human peripheral nerves. J Hand Surg Br. 1998;23:583–7. doi: 10.1016/S0266-7681(98)80006-5. [DOI] [PubMed] [Google Scholar]
  • 19.Kanaya F, Firrell JC, Breidenbach WC. Sciatic function index, nerve conduction tests, muscle contraction, and axon morphometry as indicators of regeneration. Plast Reconstr Surg. 1996;98:1264–71. doi: 10.1097/00006534-199612000-00023. discussion 1272–4. [DOI] [PubMed] [Google Scholar]
  • 20.Rupp A, Dornseifer U, Fischer A, et al. Electrophysiologic assessment of sciatic nerve regeneration in the rat: surrounding limb muscles feature strongly in recordings from the gastrocnemius muscle. J Neurosci Methods. 2007;166:266–77. doi: 10.1016/j.jneumeth.2007.07.015. [DOI] [PubMed] [Google Scholar]
  • 21.Lundborg G. A 25-year perspective of peripheral nerve surgery: evolving neuroscientific concepts and clinical significance. J Hand Surg Am. 2000;25:391–414. doi: 10.1053/jhsu.2000.4165. [DOI] [PubMed] [Google Scholar]
  • 22.Wilson ADH, Hart A, Brannstrom T, Wiberg M, Terenghi G. Primary sensory neuronal rescue with systemic acetyl-l-carnitine following peripheral axotomy. A dose-response analysis. Br J Plast Surg. 2003;56:732–9. doi: 10.1016/j.bjps.2003.08.005. [DOI] [PubMed] [Google Scholar]
  • 23.Wilson ADH, Hart A, Brännström T, Wiberg M, Terenghi G. Delayed acetyl-l-carnitine administration and its effect on sensory neuronal rescue after peripheral nerve injury. J Plast Reconstr Aesthet Surg. 2007;60:114–8. doi: 10.1016/j.bjps.2006.04.017. [DOI] [PubMed] [Google Scholar]
  • 24.Kanaya F, Firrell JC, Breidenbach WC. Sciatic function index, nerve conduction tests, muscle contraction, and axon morphometry as indicators of regeneration. Plast Reconstr Surg. 1996;98:1264–71. doi: 10.1097/00006534-199612000-00023. [DOI] [PubMed] [Google Scholar]
  • 25.Toriumi DM, O’Grady K, Desai D, Bagal A. Use of octyl-2-cyanoacrylate for skin closure in facial plastic surgery. Plast Reconstr Surg. 1998;102:2209–19. doi: 10.1097/00006534-199811000-00062. [DOI] [PubMed] [Google Scholar]
  • 26.Yoshii E. Cytotoxic effects of acrylates and methacrylates: Relationships of monomer structures and cytotoxicity. J Biomed Mater Res. 1997;37:517–24. doi: 10.1002/(sici)1097-4636(19971215)37:4<517::aid-jbm10>3.0.co;2-5. [DOI] [PubMed] [Google Scholar]
  • 27.Sohn JJ, Gruber TM, Zahorsky-Reeves JL, Lawson GW. Comparison of 2-ethyl-cyanoacrylate and 2-butyl-cyanoacrylate for use on the calvaria of CD1 mice. J Am Assoc Lab Anim Sci. 2016;55:199–203. [PMC free article] [PubMed] [Google Scholar]
  • 28.Singer AJ, Quinn JV, Hollander JE. The cyanoacrylate topical skin adhesives. Am J Emerg Med. 2008;26:490–6. doi: 10.1016/j.ajem.2007.05.015. [DOI] [PubMed] [Google Scholar]
  • 29.Hall WW, Wrye SW, Banducci DR, Ehrlich P. Microvascular anastomosis using 2-octyl cyanoacrylate in the rat femoral artery. Ann Plast Surg. 2000;44:508–11. doi: 10.1097/00000637-200044050-00008. [DOI] [PubMed] [Google Scholar]
  • 30.Ang ES, Tan KC, Tan LH, Ng RT, Song IC. 2-octylcyanoacrylate-assisted microvascular anastomosis: comparison with a conventional suture technique in rat femoral arteries. J Reconstr Microsurg. 2001;17:193–201. doi: 10.1055/s-2001-14351. [DOI] [PubMed] [Google Scholar]
  • 31.Rickett T, Li J, Patel M, Sun W, Leung G, Shi R. Ethyl-cyanoacrylate is acutely nontoxic and provides sufficient bond strength for anastomosis of peripheral nerves. J Biomed Mater Res A. 2009;90:750–4. doi: 10.1002/jbm.a.32137. [DOI] [PubMed] [Google Scholar]

Articles from Acta Orthopaedica et Traumatologica Turcica are provided here courtesy of Turkish Association of Orthopaedics and Traumatology

RESOURCES