Abstract
Range of movement (ROM) assessment is an important strategy to increase physical-technical performance and minimize the risk of sports-related injuries. Currently, there is no consensus regarding which ROM assessment method is the most appropriate. The main objective of this study was to perform a systematic review of the test batteries available for the assessment of lower limb ROM; additionally, we compare the ROM-SPORT I battery with those previously reported in the literature. The systematic review was conducted following the Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) guidelines. The identification of publications was made by using the databases SciELO, Medline, Scopus, PubMed, and Web of Science. Based on the inclusion criteria, sixteen publications were selected and analyzed. The ROM-SPORT I battery is the most valid of the analyzed methods. This battery evaluates the ROM of eleven lower limb movements. The inclinometer with a telescopic arm and a box is a simpler, more comfortable, and faster procedure than others. The Lumbosant support and use of two examiners are essential to avoid compensatory movements to obtain reliable measurements during ROM assessment. The ROM-SPORT I is a field-based battery of tests that may be used by sports professionals, clinics, and researchers in applied settings to accurately assess and monitor lower extremity ROM.
Keywords: flexibility, lumbar support, inclinometer, reliability, injury prevention, performance
1. Introduction
Flexibility, which is defined as the intrinsic ability of tissues to achieve the maximum range of movement without sports injury [1], is one of the key components of athletic performance together with strength, endurance, speed, and coordination [2,3,4,5]. The range of motion (ROM) in quantitative terms (degrees) represents the indirect measurement of muscle extensibility [1,6,7].
A limited or restricted ROM has been considered an important intrinsic and modifiable risk factors for the most prevalent sports-related injuries, such as groin pain (limited hip adductor [8,9], and internal rotation ROMs [10,11]; hamstring (limited hip flexion ROM [12], and quadriceps (limited knee flexion ROM [10]) muscle strains; patellar (limited hip flexion ROM [13,14]) and Achilles (limited ankle dorsiflexion ROM [15]) tendinopathies; anterior cruciate ligament injury (limited hip rotation [11,15]); as well as lower back pain (limited hip flexion, extension and/or internal rotation ROMs [16,17,18], and femoropatellar pain (limited hip flexion ROM [19]).
A possible explanation for the association between limited ROM and injury risk is attributed to the fact that athletes with limited ROMs have muscle-tendon units that may not be sufficiently prepared to store and release the high amount of elastic energy generated during repeated high-intensity movements that are intrinsic to most sports (e.g., sudden acceleration and deceleration, rapid changes of directions, jumping and landing tasks), and this might predispose such players to high injury risk [12]. Likewise, limited lower extremity joint ROM (e.g., limited hip and knee flexion, and ankle dorsiflexion ROMs) may lead athletes to adopt aberrant movement patterns (e.g., excessive dynamic valgus motion at the knee) during the execution of such high-intensity dynamic tasks (e.g., cutting and landing), which is suggested to increase the risk of soft-tissue (muscle, tendon, and ligament) overloading [20,21,22].
In addition, the ROM can be decreased by high training loads and repeated movements used in technical sports actions during both training and competition throughout the season, which induces physical stress and fatigue on the muscles [23,24]. When these effects are not compensated with adequate recovery measures, the muscle, tendon units may suffer alterations in their mechanical and neuronal properties, including muscle tightness and a ROM reduction [25,26,27]. Low ROM values are related to higher sports injury, but a high ROM value does not ensure injury prevention, because injury risk is a complex and multifactorial issue. Although it is generally assumed that those competing at the highest sport levels have higher ROM values [5,28,29], a high incidence of severe sports injuries has been shown in the highest level of competition for rowing, ice-hockey, football, and rugby [30,31,32,33]. Furthermore, it has been demonstrated that high ROM values are required to adequately perform the highly demanding technical actions of gymnastics, taekwondo, diving, and figure skating [17,34,35]; in this sense, a limited ROM decreases physical performance in these sports [3,36,37,38,39]. Therefore, it is clearly necessary to assess the athlete’s ROM (especially in the major joints of the lower extremity or poly-articular muscles, due to their high rate of injuries) not only to prevent injuries, but also in certain sports, as a quantifiable training component that may be fundamental to achieving a high level of sports-related performance.
Certain articles in the scientific literature that assess athletes´ flexibility show major differences in results depending on the sport [4,34,35,40,41]. Thus, we can observe that flexibility is specific for each joint, muscle action, or movement and that for the same sport, different joints require differing degrees of flexibility [17,42]. Flexibility also differs depending on the specific position of each player in a team [43,44], between the dominant and non-dominant limb [45,46,47], and at varying competitive levels [5,28,29]. For example, the study of Gannon et al. [48] indicated that international athletes (dancers and gymnasts) present higher flexibility values (shoulder flexion and extension ROM, hip flexion, extension and abduction ROM with full knee extension, trunk ROM and ankle ROM) than national, beginners or active athletes. Moreno et al. [35] on estimating hamstring muscle flexibility using the sit and reach (SRT) test in 32 different sports, concluded that elite athletes present higher flexibility values than the general population. Battista et al. [28] concluded that university rowers present better hamstring flexibility (SRT) than amateurs, and that experienced rowers have higher flexibility [28]. De la Fuente and Gómez-Landero [5] examined the differences between Taekwondo cadet-athletes competing at different competitive levels and found that hip ROM was significantly different between medalists and non-medalists in both the passive flexion test of both legs and the abduction test in active and passive positions.
There are many published assessment tests to measure the ROM of the major joints in the lower extremities (i.e., hip, knee, and ankle) [12,49,50,51,52,53,54,55,56]. Subsequently, there are several different methodologies used to assess ROM, for example, passively (e.g., straight leg raise test [hip flexion ROM] or actively (i.e., walking step test [ankle dorsiflexion ROM], and/or using single (Thomas test [hip extension ROM]) or multi (deep back squat [hip flexion ROM] joints. Furthermore, numerous instruments have been suggested to aid measurement of ROM directly (Leighton flexometer, inclinometer or goniometer) or indirectly (measuring tape, video camera) in degrees. However, and despite the large number of published ROM tests, there is currently no consensus as to what exploratory tests are the most appropriate to assess the ROM of the major lower extremity joints [6,57]. The selection of a reference diagnostic, based on the suggestions of Hopkins [58,59], should be based firstly on the criteria of high validity and reliability, and then to value simplicity and universality of the procedure. The identification of the criterion-referenced assessment tests and the promotion of their use in differing contexts would allow practitioners to unify ROM assessment and monitoring.
The ROM-SPORT I battery is a ROM assessment method that has been used to assess the main movements of the lower limb (11 ROM tests for hip [n = 7], knee [n = 1], and ankle [n = 2]) in athletes and general population [7,24,60,61]. Currently, it seems that this battery may be the most appropriate in terms of validity, reliability, simplicity of the procedure, and low requirements of human and material resources. Therefore, the main objective of this study was to perform a systematic review of the batteries available for the assessment of the lower limb ROM; and secondly to compare the ROM-SPORT I battery with those previously reported in the literature. This review may be of importance for researchers working in sports performance, risk of sports injuries, clinical evaluation, and others. In addition, complete information about the existing ROM batteries would also be useful for sports professionals, clinics, and athletes.
2. Methods
Systematic Review
The systematic review was conducted following the Preferred Reporting Items for Systematic Reviews (PRISMA) guidelines [62]. According to the PRISMA Statement guidelines to conduct a systematic review [62], which include the following four steps: Identification, screening, eligibility, and inclusion (Figure 1).
Figure 1.
Flow diagram of the systematic review process.
The systematic computerized search was conducted up to 5th August 2020. The identification of publications was made by using the databases Google Scholar, SciELO, Medline, Scopus, PubMed, and Web of Science. The search strategy for identification used the Boolean constructs and combinations of the relevant keywords “flexibility”, “range of motion”, “Range of movement”, and “ROM”. The descriptors “flexibility”, “range of motion”, and “Range of movement” were used with the search operators “OR” and “AND”.
The purpose of the first screening of publications was to select those written in English and to discard publications in the form of literature reviews, abstracts, editorial commentaries, and letters to the editor. Then, the eligibility process for publications was performed according to the following inclusion criteria: (1) Being published before August 2020, (2) research studies assessing the ROM of lower limbs, (3) studies including a battery with at least four ROM tests, (4) articles describing the tests including details, such as starting and final position, type of movement, compensation control, repetitions or trials, human and material resources, (5) using a sample of at least 15 participants, and (6) reporting the reliability.
Two independent reviewers (A.C. and P.S.B.) selected the publications that met the searching, screening, and inclusion criteria. Disagreements were resolved by consulting a third reviewer (F.S.M.).
The variables that were obtained from those publications chosen in this systematic review (data extraction) were classified into twelve categories: (1) General descriptors (authors and publication year), (2) estimated time for testing, (3) warm-up regimen before testing, (4) participant´s starting position, (5) movement testing, (6), measurement procedure (instruments and human resources), (7) types of range of motion evaluated, (8), criteria for end-of test, (9) control of compensatory movements, (10), number of assessment sessions and repetitions for each ROM test, (11) validity and (12) reliability. These categories are considered the most important features are describing the ROM measurement methods [6,57,63]. The ROM-SPORT I battery is a sport-specific ROM assessment tool [40,49,63]. In order to investigate the possible advantages of the ROM-SPORT I battery, this battery was compared with the rest of the ROM assessment batteries published according to these 12 categories.
3. Results
A total of 2896 publications were initially identified using Google Scholar, SciELO, Medline, Scopus, PubMed, and Web of Science. At the end of the screening and eligibility processes based on the inclusion criteria, sixteen publications were selected and analyzed (Figure 1). These sixteen publications describe ROM assessment methods consisting of batteries or groups of ROM tests, each ROM test corresponding to the assessment of a specific joint movement; the extensibility of a muscle and other joint tissues are measured in each joint movement. Table 1 shows the information regarding the 12 descriptive categories of the ROM measurement methods described in the 16 studies selected in the systematic review.
Table 1.
A summarized of all the variables studied in the 16 selected publications of the batteries for the assessment of the lower limb range of movement.
Reference | Estimate Time for Testing | Warm-up before Testing | Participant´s Starting Position | Movement Testing | Measurement Procedure (Instruments, Material and Human Resources) | Types of Range of Movement (ROM) Evaluated | Criteria for End-of Test | Control of Compensatory Movements | Number of Assessment Sessions and Repetitions | Validity | Reliability |
---|---|---|---|---|---|---|---|---|---|---|---|
Ekstrand et al. [55] | No detail | No | Supine | Hip extension | 2-examiners Velcro bands Anatomical landmark Standard GM Leighton flexometer |
Passive | Maximum ROM | APT | 2 testing sessions 1 rep |
No detail | CV = 1.2% |
Supine | Hip flexion, knee extension | PPT Contralateral hip flexion |
CV = 1.4% | ||||||||
Supine | Hip abduction, knee flexion | No detail | CV = 2.5% | ||||||||
Supine | Knee flexion | APT | CV = 1.1% | ||||||||
Standing | Ankle dorsiflexion, neutral knee | Knee flexion, heel on the ground |
CV = 2.5% | ||||||||
Standing | Ankle dorsiflexion, maximum knee flexion | Heel on the ground | CV = 2.6% | ||||||||
Moller et al. [64] | No detail | Yes | Supine | Hip extension | 2-examiners Velcro bands Anatomical landmark Standard GM |
Passive | Maximum ROM | APT | 2 testing sessions 1 rep |
No detail | CV = 1.2% |
Supine | Hip flexion, knee extension | PPT, contralateral hip flexion |
CV = 1.4% | ||||||||
Supine | Hip abduction, knee flexion | No detail | CV = 2.5% | ||||||||
Supine | Knee flexion | APT | CV = 1.1% | ||||||||
Standing | Ankle dorsiflexion, neutral knee | Knee flexion, heel on the ground |
CV = 2.5% | ||||||||
Standing | Ankle dorsiflexion, maximum knee flexion | Heel on the ground | CV = 2.6% | ||||||||
Reid et al. [65] | No detail | Yes | Supine | Hip extension, knee relax | 2-examiners Velcro bands Anatomical landmark Standard GM |
Passive | Compensation movements | APT | 3 testing sessions, alternate days 3 reps |
No detail | CV = 4.3% |
Supine | Hip flexion, knee flexion | No detail | No detail | ||||||||
Supine | Hip abduction, neutral knee | No detail | No detail | ||||||||
Lateral | Hip adduction (Ober test) | No detail | No detail | ||||||||
Sitting | Hip internal rotation | No detail | No detail | ||||||||
Sitting | Hip external rotation | No detail | No detail | ||||||||
Clapper et al. [66] | No detail | No detail | Supine | Hip flexion | 2-examiners Anatomical landmark Standard GM Orthoranger pendulum oriented perpendicular to the long axis of the moving segment |
Active | No detail | No detail | 3 testing sessions (3-week apart) 3 reps |
No detail | ICC GM = 0.95 ICC ORR = 0.89 |
Prone | Hip extension, neutral knee | ICC GM = 0.83 ICC ORR = 0.72 |
|||||||||
Standing | Hip abduction | ICC GM = 0.86 ICC ORR = 0.79 |
|||||||||
Standing | Hip adduction | ICC GM = 0.80 ICC ORR = 0.77 |
|||||||||
Supine | Hip internal rotation | ICC GM = 0.92 ICC ORR = 0.86 |
|||||||||
Supine | Hip external rotation | ICC GM = 0.80 ICC ORR = 0.86 |
|||||||||
Supine | Knee flexion | ICC GM = 0.95 ICC ORR = 0.91 |
|||||||||
Supine | Knee extension | ICC GM = 0.85 ICC ORR = 0.80 |
|||||||||
Supine | Ankle dorsiflexion | ICC GM = 0.92 ICC ORR = 0.80 |
|||||||||
Supine | Ankle plantar flexion | ICC GM = 0.96 ICC ORR = 0.93 |
|||||||||
Wang et al. [67] | No detail | Yes | Supine | Hip extension, neutral knee | 2-examiners Bledsoe knee brace Anatomical landmark Standard GM |
Passive | Compensation movements | APT | 2 testing sessions (1–2 days apart) No detail |
No detail | ICC = 0.97 |
Supine | Hip extension, 90° knee flexion | No detail | ICC = 0.97 | ||||||||
Supine | Hip flexion, neutral knee | PPT | ICC = 0.90 | ||||||||
Supine | Ankle dorsiflexion, neutral knee | Maximun ROM | No detail | ICC = 0.98 | |||||||
Prone | Ankle dorsiflexion, 90° knee flexion | No detail | ICC = 0.93 | ||||||||
Witvrouw et al. [12] | No detail | No detail | Supine | Hip flexion, knee flexion | 2-examiners Anatomical landmark Standard GM |
Passive | No detail | No detail | No detail | Based on the study by Gogia et al. [68] | No detail |
Supine | Hip abduction | Compensation movements | Hip rotation | ||||||||
Prone | Knee flexion | Maximum ROM | No detail | ||||||||
Standing | Ankle dorsiflexion, neutral knee | Compensation movements | Heel on the floor | ||||||||
Steinberg et al. [69] |
No detail | No | Prone | Hip extension, knee extension | 2-examiners Anatomical landmark Standard GM |
Active | Compensation movements | Stabilized pelvis | Two testing sessions (1 day apart) consecutive days No detail |
No detail | Pearson r = 0.91 |
Supine | Hip abduction, knee extension | Passive | Hip rotation | Pearson r = 0.96 | |||||||
Prone | Hip internal rotation, 90° knee flexion | Stabilized pelvis | Pearson r = 0.89 | ||||||||
Prone | Hip external rotation, 90° knee flexion | Stabilized pelvis | Pearson r = 0.89 | ||||||||
Supine | Hip flexion, knee flexion | PPT | Pearson r = 0.95 | ||||||||
Supine | Knee flexion | No | Pearson r = 0.93 | ||||||||
Supine | Ankle dorsiflexion, neutral knee | Passive | Compensation movements | Ankle and foot neutral position | Pearson r = 0.90 | ||||||
Supine | Ankle plantarflexion, neutral knee | Pearson r = 0.91 | |||||||||
Bradley and Portas [50] |
No detail | No detail | Prone | Hip extension, neutral knee | 2-examiners Reflective skin markers Software for 2-dimensional image-based analysis Video camera |
Passive | Feeling of stretching | No detail | No detail 1 rep |
No detail | ICC Hip = 0.92 |
Supine | Hip flexion, flexion knee | ||||||||||
Supine | Knee flexion, hip flexion | ICC knee = 0.95 | |||||||||
Supine | Knee extension, hip flexion | ||||||||||
Supine | Ankle plantarflexion, neutral knee | ICC ankle = 0.91 | |||||||||
Supine | Ankle dorsiflexion, neutral knee | ||||||||||
Pua et al. [70] | No detail | No detail | Supine | Hip extension, 80° flexion knee | 1-examiner Strap Anatomical landmark Extendable GM Electronic inclinometer |
Passive | Firm end sensation Presence of pain |
PPT, flattened lumbar spine |
2 testing sessions (at least 1 week) 2 reps |
No detail | MDC (90% IC) = 10.5° |
Supine | Hip extension, knee unconstrained | MDC (90% IC) = 11° | |||||||||
Supine | Hip abduction, neutral knee | Stabilized pelvis | MDC (90% IC) = 7.3° | ||||||||
Sitting | Hip internal rotation | No detail | MDC (90% IC) = 7.8° | ||||||||
Sitting | Hip external rotation | MDC (90% IC) = 7.1° | |||||||||
Supine | Hip flexion, flexion knee | APT, contralateral hip flexion |
MDC (90% IC) = 8.2° | ||||||||
Bozic et al. [54] | 25 min/group muscle | Yes | Supine | Hip abduction, neutral knee | 2-examiners (a) Anatomical landmark Kinanthropometry, ruler and protractor Trigonometric calculations (b) Reflective markers 3D kinematic analysis system |
Passive | Maximum ROM | No detail | 2 testing sessions (1 week apart) 3 reps |
Concurrent validity 3D kinematic analysis system vs Field methods ICC: 0.66 to 0.96 CV: 0.8 to 3.5% |
ICC = 0.87; CV = 3.4% |
Supine | Hip flexion, neutral knee | ICC = 0.87; CV = 2.1% | |||||||||
Standing | Single-legged knee bend | Active | ICC = 0.57; CV = 3.9% | ||||||||
Standing | Sideward leg splits | Active | ICC = 0.89; CV = 2.3% | ||||||||
Sitting | Sit and reach | Passive | ICC = 0.94; CV = 6.7% | ||||||||
Standing | Sideways leg splits | Active | ICC = 0.88; CV = 2.4% | ||||||||
Standing | Lengthwise leg splits | Active | ICC = 0.85; CV = 3% | ||||||||
Nussbaumer et al. [56] | No detail | No detail | Supine | Hip adduction, neutral knee | 2-examiners (a) Anatomical landmark Standard GM Longitudinal axis (b) Anatomical landmark and sensor location ETS (electromagnetic tracking system) |
Passive | Force application | No detail | 2 testing sessions (1 week apart) 3 reps |
Concurrent validity LOA: 3.3° ICC:0.53 |
GM (ICC = 0.84; CV = 6.7%) ETS (ICC = 0.82; CV = 6.3%) |
Hip abduction, knee extension | Concurrent validity LOA: 1.9° ICC:0.93 |
GM (ICC = 0.92; CV = 5.8%) ETS (ICC = 0.94; CV = 5.6%) |
|||||||||
Hip internal rotation, 90° hip and knee flexion | Concurrent validity LOA: 8.1° ICC:0.87 |
GM (ICC = 0.95; CV = 7.7%) ETS (ICC = 0.90; CV = 10.2%) |
|||||||||
Hip external rotation, 90° flexion hip and knee | Concurrent validity LOA: 3.5° ICC: 0.54 |
GM (ICC = 0.91; CV = 5.2%) ETS (ICC = 0.93; CV = 5.1%) |
|||||||||
Hip flexion, flexion knee | Construct validity (not differ between FAI and control) Concurrent validity (LOA: 18.9°; ICC: 0.44) |
GM (ICC = 0.91; CV = 3.1%) ETS (ICC = 0.94; CV = 2.6%) |
|||||||||
Fourchet et al. [53] | No detail | No detail | Supine | Hip abduction, neutral knee | Two examiners Anatomical landmarks Hand-held dynamometer Force application Video capture digital Digital motion analysis software |
Passive | Force application | No detail | 2 testing sessions (3 days apart) No detail |
No detail | CV (90% IC) = 7.2%; ICC = 0.85 |
Hip extension, knee flexion | CV (90% IC) = 2.6%; ICC = 0.51 | ||||||||||
Hip internal rotation | CV (90% IC) = 9.6%; ICC = 0.92 | ||||||||||
Hip external rotation | CV (90% IC) = 12.4%; ICC = 0.91 | ||||||||||
Knee flexion, neutral hip | CV (90% IC) = 8.3%; ICC = 0.86 | ||||||||||
Knee extension, 90° hip flexion | CV (90% IC) = 2.6%; ICC = 0.51 | ||||||||||
Prone | Ankle dorsiflexion, neutral knee | CV (90% IC) = 4.5%; ICC = 0.93 | |||||||||
Ankle dorsiflexion, 90° knee flexion | CV (90% IC) = 5.7%; ICC = 0.66 | ||||||||||
Tainaka et al. [71] | No detail | No detail | Prone | Hip extension, neutral knee | 1-examiner Anatomical landmarks Standard GM |
Active | No detail | Stabilized pelvis and spine | 2 testing sessions (1-week apart) 3 reps |
No detail | Pearson r > 0.85 |
Supine | Hip adduction | ||||||||||
Hip abduction, neutral knee | |||||||||||
Hip internal rotation, 90° hip and knee flexion | |||||||||||
Hip external rotation, 90° flexion hip and knee | |||||||||||
Hip flexion, knee flexion | |||||||||||
Cejudo et al. [45] | 1 min | Yes | Supine | Hip extension, knee flexion | Two examiners Lumbar support “Lumbosant” (Imucot Traumatología SL, Murcia, Spain) Longitudinal axis (imaginary bisector line) Inclinometer with atelescopic rod |
Passive | Firm end sensation Compensatory movements (lumbar spine, pelvis or lower limb) Feeling of stretching |
APT | 3 testing sessions (2-week apart) 2 or 3 (variation > 5%) |
Content validity by American medical organizations | SEM = 1.3°; MDC = 3.7°; ICC = 0.96 Cejudo et al. [63] |
Supine | Hip adduction, 90° knee flexion | Transversal pelvis rotation | SEM = 1.8°; MDC = 4.5°; ICC = 0.92 Unpublished data |
||||||||
Supine | Hip abduction, neutral knee | Frontal pelvis rotation, contralateral knee extension, transversal hip rotation |
SEM = 1.8° MDC = 5.5°; ICC = 0.93; Cejudo et al. [63,72] |
||||||||
Supine | Hip abduction, 90° hip and knee flexion | Transversal pelvis rotation | SEM = 2.1°; MDC = 5.8°; ICC = 0.99 Cejudo et al. [72] |
||||||||
Supine | Hip flexion, extension knee | PPT, knee flexion, hip rotation, contralateral hip flexion |
SEM = 1.9°; MDC = 6.1°; ICC: 0.91; Cejudo et al. [63] |
||||||||
Supine | Hip flexion, flexion knee | SEM = 2.5°; MDC = 6.2°; ICC = 0.90 Cejudo et al. [63] |
|||||||||
Supine | Knee flexion, neutral hip | APT, hip rotation |
SEM = 2.8°; MDC = 6.9°; ICC = 0.89; Cejudo et al. [63] |
||||||||
Prone | Hip internal rotation, neutral hip and 90° knee flexion | Transversal pelvis rotation, hip abduction |
SEM = 2.5°; MDC = 6.8°; ICC = 0.92 Unpublished data |
||||||||
Prone | Hip external rotation, neutral hip and 90° knee flexion | Transversal pelvis rotation, hip abduction |
SEM = 2.5°; MDC = 6.8° ICC = 0.92 Unpublished data |
||||||||
Standing | Ankle dorsiflexion, neutral knee | Heel on the floor, Knee flexion |
SEM = 1.7°; MDC = 4.7°; ICC = 0.95 Cejudo et al. [63] |
||||||||
Standing | Ankle dorsiflexion, Knee flexion | Heel on the floor | SEM = 1.8°; MDC = 5°; ICC = 0.95 Cejudo et al. [63] |
||||||||
Shah et al. [11] | No detail | Yes | Prone | Hip extension | 2-examiners Lateral midline of the thigh and horizontal axis of the body 2-examiners Bony landmark Standard GM |
Passive | No detail | No details | 2 testing sessions 1 rep |
No detail | ICC = 0.62 |
Supine | Hip flexion | Compensation movements Maximum ROM |
ICC = 0.77 | ||||||||
Hip internal rotation, 90° flexion hip and knee | Transversal pelvis rotation, lumbar lateral flexion |
ICC = 0.77 | |||||||||
Hip external rotation, 90° flexion hip and knee | ICC = 0.90 | ||||||||||
Grazette et al. [73] | No detail | No detail | Standing | Ankle dorsiflexion, knee flexion | Centimeters measurement units | Passive | Maximum ROM | Heel on the floor, knee flexion, foot pronation, foot supination, pelvic rotation, knee valgus or varus |
2 testing sessions (3–7 days apart) No detail |
No detail | ICC = 0.95 CV = 35.9° |
Supine | Medial hip rotation, 90˚ hip and knee | 2-examiners Standard GM |
Passive | Firm end sensation | No detail | ICC = 0.72 CV = 8.3° |
|||||
Prone | Hip internal rotation | Passive | ICC = 0.70 CV = 36.5° |
||||||||
Supine | Hip external rotation | Active | ICC = 0.82 CV = 49° |
||||||||
Supine | Knee extension (Hamstring 90/90) | Passive | ICC = 0.47 CV = 65.3° |
GM, goniometer; ORR, orthoranger; APT, anterior pelvis tilt, PPT, posterior pelvis tilt; CV, coefficient of variation at 95% confidence intervals; ICC, intraclass correlation coefficient; SEM, standard error of the mean; MDC, minimal detectable change at 95% confidence intervals (CI).
3.1. Estimated Time for Testing
Data describing this parameter is very scarce in the literature, and in general, this information is rarely provided. Only Bozic et al. [54] and Cejudo et al. [42,45] indicate the estimated testing time, which was 25 min and 1 min for each ROM test, respectively. The testing duration of the ROM-SPORT I battery (11 ROM tests and both sides of the body) varies from approximately 8–11 min [40,42,45].
3.2. Warm-Up before Testing
Six studies reported using a warm-up before measuring the ROM [11,45,54,64,65,67]. No warm-up exercises were undertaken in the studies of Ekstrand et al. [74] and Steinberg at al. [69]. The other selected publications did not provide information relating to a warm-up [12,50,66,70,71,73].
3.3. Participant’s Starting Position
Athletes are placed in different starting positions depending on the study. The starting positions described are standing, supine, prone, lateral, and sitting. Testing in a supine position was the most commonly used starting position to assess the ROM, followed by the prone position.
3.4. Movement Testing
The assessment batteries selected in this systematic review include between four [12] and eleven [42,45] ROM tests. The ROM tests selected in each study depended on the objective of the study. For hip ROM, the movements tested were: (1) Hip extension with neutral knee, relax knee flexion or 80° knee flexion (supine, sagittal plane) for iliopsoas; (2) hip adduction with 90° hip flexion (supine, transversal plane) for the hip abductors muscles; (3) hip flexion with knee extension or knee extension with 90° hip flexion “Hamstring 90/90” (supine, sagittal plane) for hamstrings; (4) hip flexion with relax flexion knee (supine, sagittal plane) for gluteus maximus; (5) hip abduction with neutral knee (supine, frontal plane) for adductors; (6) hip abduction with 90° knee flexion (supine, transversal plane) for monoarticular adductors; (7) hip internal rotation with neutral hip and 90° knee flexion (prono, transversal plane) or 90° hip and knee flexion (supine, transversal plane) for external rotator muscles; and (8) hip external rotation with neutral hip and 90° knee flexion (prono, transversal plane) or 90° hip and 90° knee flexion (supine, transversal plane) for internal rotator muscles ROM tests. For the knee ROM assessment, the movements tested were: (1) Knee flexion with neutral hip (supine, sagittal plane) for quadriceps; and (2) knee extension (supine, sagittal plane) for hamstrings. The ankle joints ROM were evaluated by testing (1) ankle dorsiflexion with 90° knee flexion or maximum knee flexion (standing, sagittal plane) for soleus, (2) ankle dorsiflexion with neutral knee (standing, sagittal plane) for gastrocnemius, and (3) ankle plantar flexion (supine, sagittal plane) for ankle flexor muscles.
3.5. Measurement Procedure (Instruments, Material and Human Resources)
The most commonly used measuring instrument for ROM is the two-armed standard goniometer (GM). In addition, other measurement instruments include certain field based methods—Kinanthropometry, ruler and protractor [54,73], extendable GM [73], Leighton flexometer [74], Orthoranger [66], electronic inclinometer [70], inclinometer with a telescopic rod [45,63], electromagnetic tracking system [56], and video capture digital and software for 2- or 3-dimensional image-based analysis [50,53,54].
All selected studies reported that ROM assessment procedures were performed by two experienced examiners, except for the studies of Pua et al. [70] and Tainaka et al. [71] with only one examiner employed. Routinely, one examiner performs the movement, and the second examiner measures the angle with GM. However, Cejudo et al. [45,63] reported that the main examiner executes the movement and takes the ROM measures, while the assistant examiner maintains the initial position of the subject (zero position) and controls compensatory movements, which is considered a major contribution of their protocol.
Most authors used anatomical landmarks to determine the sides of the ROM angle or to measure the angle from an initial position. When measuring with digital capture, the examiner places reflective skin markers on certain bone points [53,54]. Other examiners simplify the procedure by placing the measuring instrument in the longitudinal axis of the mobilized segment through the imaginary bisector line [45,56,63], instead of using landmarks.
3.6. Types of ROM Evaluated
The maximal passive and active ROM are the types of movement used in the studies. Specifically, maximum passive movement is predominantly used in the observed studies (13 out of 16 publications).
3.7. Criteria for End-Of Test
Five criteria of end-of ROM test were established by the authors: (1) Feeling of stretching or tolerable stretch, no pain [45,50,63,69], (2) point of resistance, firm or stiff end sensation [40,63,70,71], (3) maximum ROM [11,12,45,54,55,63,64,67], (4) the emergence of compensatory movements [11,12,40,63,65,67], or (5) standardized force application [53,56]. Usually, the authors consider two or three of these end-of ROM test criteria in their studies. Most of these criteria are subjective because they are based on qualitative observations, except the criterion of force application; in this case, the quantification of the applied force determines the test end [53,56].
3.8. Control of Compensatory Movements
Only six studies outline information related to the control of compensatory movements during ROM measurements, such as a compensatory trunk, pelvis (rotation, lateral tilting, anterior and posterior pelvis tilt), opposite hip (flexion, rotation, and abduction), knee (flexion and extension) and ankle and foot (pronation, supination, and heel on the ground) movements [45,63,64,65,67,70,74]. Different methods were used to avoid these compensatory movements, including velcro bands or straps [67,70,74], the explored athlete himself [12,45,63,64,74], Bledsoe knee brace [67], and the lumbar support tool, “Lumbosant” (Imucot Traumatología SL, Murcia, Spain), together with an assistant examiner [45,63].
3.9. Number of Assessment Sessions and Repetitions
Selected studies reported two or three assessment sessions. It is understood that other studies used a single assessment session [12,50].
These studies described one, two or three repetitions or trials of each ROM test. Studies that do not provide this information are understood to carry out a single repetition [12,53,67,69].
3.10. Validity
The validity criterion is not reported by most of the selected studies. Witvrouw et al. [12] and Cejudo et al. [40] report criterion validity (gold standard) of their ROM tests based on previous studies reported by Gogia et al. [68] and Enwemeka et al. [75]. In addition, Cejudo et al. [45,63] report content validity for the battery´s ROM tests taken as reference values from the anatomical knowledge and extensive clinical, and sports experience of two American medical organizations (American Medical Association [6] and American Academy of Orthopaedic Association [76]). The studies of Bozic et al. [54] and Nussbaumer et al. [56] determined the concurrent validity between their digital motion measurement method (kinematic analysis) and field methods.
3.11. Reliability
All publications report reliability of their ROM measuring batteries. However, different populations studied, the same examiner or several examiners, research designs, and statistical tests have been used to calculate the reliability values of measurement.
Authors displayed coefficient of variation (CV) values ranging from 1.1 to 2.6% [64,74], Bozic et al. [54] from 2.1% to 6.7%, Nussbaumer et al. [56] from 2.6% to 10.2%, Fourchet et al. [53] from 2.6% to 12.4% and Reid et al. [65] reports an average of 4,3%. In sense, Grazette et al. [73] show CV values between 8.3° to 65.3°.
Grazette et al. [73] reported intraclass correlation coefficients (ICC) values between 0.47 to 0.95, Fourchet et al. between 0.51 to 0.92 [53], Bozic et al. between 0.57 to 0.94 [54], Shah et al. between 0.62 to 0.90 [11], Clapper et al. between 0.72 to 0.95 [66], Nussbaumer et al. between 0.82 to 0.95 [56], Cejudo et al. between 0.89 to 0.96 [63,72], Wang et al. [67] between 0.90 to 0.97, and Bradley and Portas [50] between 0.91 to 0.95.
Pua et al. [70] reported minimum detectable change values (MDC) at a 90% confidence interval between 7.1° to 11°, and Cejudo et al. [52,76] reported MDC at a 95% confidence interval between 3.7° and 6.9°. Lastly, Steinberg et al. [69] reported Pearson r values between 0.89 to 0.96, and Tainaka et al. [71] reported average values of 0.85.
4. Discussion
A battery of ROM evaluation tests should be characterized by: (1) Inclusion of measurement of the extensibility of the major joints of the lower extremities (at least 11 ROM tests), (2) a simple exploratory procedure to administer, (3) allows examiners to directly assess (in degrees) the ROM in a very short period of time, (4) austerity in human and material resources that especially aim to avoid compensatory movements, (5) valid ROM test and (6) reliable ROM test. Examiners and researchers should consider the strengths and limitations of each method (Table 1) when measuring ROM in athletes and the general population. This section aims to discuss and analyze the different batteries available for the evaluation of ROM as described in the selected publications according to the optimal characteristics of an assessment procedure.
The estimated time for testing ROM using an inclinometer with a telescopic rod (method of ROM-SPORT I battery) is 1 min per ROM test [45,63]. The ROM-SPORT I battery presents a much faster procedure than the procedures proposed by the other authors. The marking of anatomical landmark, the complexity of using the measuring instrument (GM, electronic computerized goniometer, Leighton flexometer, capture digital, electromagnetic tracking system), and the additional use of hand-held dynamometers leads to a considerable increase in the estimated time for testing—more than 3 min per ROM test [54]. This time is still higher if the ROM is subsequently measured using a digital image or video capture or an electromagnetic tracking system. After obtaining a digital image or video, examiners still need to measure the angle with digital motion analysis software [53,54]; also, a lot of time is spent on locating the body area and attaching the sensors of electromagnetic tracking system with double-sided tape, flexible medical adhesive tape, and a velcro band, all increasing the time needed for the assessment. In addition, the increased complexity of the procedure is associated with an increase in the variability and potential error of the measure [58,77].
The warm-up mainly has three aims: (1) To minimize the risk of muscle injury because all the tests required a large muscle tension stimulus [78,79], (2) to reduce the effects of muscle lengthening on repeated trials during data collection [80,81], and (3) to reduce the variability and standard error of measurements by minimizing the effect of different muscle temperature on muscle flexibility [81] that could be, for example, caused by the different means transport (walking, bike, car…) employed by the athletes to reach de assessment session. However, there are certain circumstances where the examiners do not have sufficient time to warm-up, such as the limited time provided by coaches or the time required for other tests different from flexibility.
Trying to reduce the participant positioning during tests is essential to reduce the time it takes to complete the test battery. In addition, appropriate starting positions and movements (movements contrary to the muscle actions) ensures specific muscle extensibility and ROM measurement [63,82]. Starting or ‘zero position’ [6] that is used in the studies of Nussbaumer et al. [56] and Cejudo et al. [45,63] facilitates the measurement of the ROM only once (at the final test position).
The ROM tests selected in each ROM assessment battery depend on the objective of the study. The main movements of the lower limb are hip extension, hip adduction with the hip flexed 90°, hip flexion with the knee flexed and extended, hip abduction with the hip neutral and hip flexed 90°, hip external and internal rotation, knee flexion, ankle dorsiflexion with the knee flexed and extended ROMs. These movements have usually been selected in the scientific literature because limited ROM, induced by muscle tightness, increases the sports injury risk [24,83] and decreases athletic physical-technical performance [3,36,38]. In addition, the measurement results of each of these ROMs in ascending order determines the lower, limb flexibility profile in the sport and is based on the specificity of this component of physical fitness to a given sport [7,17,42,45,49,83].
The ROM assessment using an inclinometer with a telescopic rod (method of the ROM-SPORT I battery) appears to be a simpler and faster method than using other instruments (Table 1). It has the advantage of not requiring the marking of bony landmarks, since the maximum ROM values can be determined as the angle formed by the longitudinal axis of the leg (lateral or anterior bisector of the leg) within the vertical or horizontal planes. In this sense, the initial and final positions can be identified with systematic and repetitive precision [6,50,63,72,84]. Also, using an inclinometer with a telescopic arm turns the instrument into a one-arm goniometer, with the advantage of having a gravity level that allows for the better precision of measurements, and subsequently, increasing measuring speed [6,63,72]. In addition, this instrument does not have the disadvantage of, for example, the goniometer, which requires the precise positioning of its arms, while moving the goniometer at the same time as the limb [6,63]. Finally, and unlike other more sophisticated tools, the cost of an inclinometer is relatively low (ranging from 110 to 150€).
Two experienced examiners are required to measure hip and knee ROMs. In the measurement with GM participate, two examiners, the main examiner perform the ROM tests movements, while the assistant examiner place the two, armed GM on the two body segments. However, generally, there is no control over the compensatory movements in this method, which may result in an imprecise measure (high standard error of measurement). This is a limitation of the ROM assessment with GM, since it is essential to avoiding compensatory movements, which may result in imprecise measures (high standard error of measurement) [84,85,86]. A recent study by Santonja et al. [84] observed 13.9° less hip flexion with knee extension or “Straight Leg Raising” test when the compensatory movements were not controlled for by the lumbar support tool, “Lumbosant” (Imucot Traumatología SL, Murcia, Spain), together with an assistant examiner. For examiners to take on more competences, Cejudo et al. [63,72,87] recommend using an inclinometer with a telescopic rod, which behaves like a single one-armed GM. This measuring instrument allows the main examiner to perform the movement and measurement of the ROM with the inclinometer, while the assistant examiner avoids the compensatory movements.
The use of anatomical landmarks and the placement of reflective skin markers or Orthoranger pendulum considerably increases the measurement time of any ROM assessment battery. To reduce the time of the measurement procedure, Cejudo et al. [45,63] and Nussbaumer et al. [56] used a movable armed GM or telescopic rod of an inclinometer with a longitudinal axis of the mobilized segment, following its imaginary bisector line. Compared to the GM, the inclinometer with a telescopic rod allows the examiner to simultaneously perform compensatory movement control, movement testing, and ROM measurement [45,63].
The passive maximal measurement is the most commonly used maneuver in the selected studies [11,12,42,53,54,56,63,64,65,67,69,70,73,74]. The use of passive movements is based on the following two reasons: First, in several of the active tests, the peak ROM depends on the participant’s muscle strength (mainly psoas, hamstring, quadriceps) and the ability to simultaneously contract the agonist muscles and relax the antagonist muscles that are to be measured [88]. This makes the application of the active tests very limited in individuals with lower absolute strength of specific muscles, such as children and adolescents [89]. Furthermore, it does not compare the ROM values between sex and sport disciplines, due to the different strength profile of their participants [4]. Second, the active tests are strongly influenced by the participant’s motivation to actively move the joint until achieving the peak ROM, which can be considered a source of error of the measurement (intra-individual variability) [6]. However, it should be noted that the ROM assessment tests of the ankle joint are active, due to the fact that the passive measurements are technically more difficult to carry out, which has shown to negatively influence the precision of the measurement obtained from them [90].
Furthermore, all the selected passive tests specifically measure a single joint movement. The tests that imply using more than one joint (i.e., sit and reach, Functional Movement Screen [FMS®]) might not accurately assess ROM, as they may be biased by other factors, such as anthropometry (length of the limbs), and inter-muscular coordination (dynamic stability) which could limit the validity of the results.
The ROM is the measurement of movement around a specific joint in the body. The aim of the ROM measurement is to indirectly quantify muscle extensibility [1,6,63]. Usually, a maximum passive movement is performed by the main examiner [12,45,54,63,66,69,74]. However, the test can be terminated earlier if an examiner felt or appreciated some compensatory movement that may increase the ROM [45,63].
Lastly, the aim of ROM measurement is to quantify muscle extensibility. For that reason, the maximum movements opposed to the actions of the muscle must be performed during the ROM test procedure for the subject or athlete to feel the muscle stretching as the final criterion of the test [45,50,63,69] without reaching the pain point, which can request myotactic reflex.
The control of the applied force during the movement of the ROM test contributes to the standardization of the protocol and adds a new criterion for the end of the ROM test [53,56]. However, the inclusion of this criterion considerably increases the complexity of the procedure and increases the evaluating time and the error of the measure.
Compensatory movements in the trunk, pelvis, opposite lower limb, ankle, and foot are produced during the measurement of lower limb ROM [63,64,65,67,70,74]. The studies of Cejudo et al. [45,63,72] precisely detail the possible compensatory movement pattern in each ROM test of the ROM-SPORT I battery; these authors report that the lumbar support tool, “Lumbosant” (Imucot Traumatología SL, Murcia, Spain), and two examiners can help in minimizing compensatory movements of the hip and knee during ROM tests. For ankle ROM tests, the athlete and the main examiner control the compensatory movements [87]. This method is better in helping to limit compensatory movements of the trunk, pelvis, and lower limb than the use of velcro bands or straps [63,72]. The lumbar support tool, “Lumbosant” (Imucot Traumatología SL, Murcia, Spain), is a reference for the assistant examiner to keep the pelvis in a zero/neutral position [84]. The task of the assistant examiner is to provide the proper stability based on the initial position, by fixing a certain segment of the pelvis throughout the assessment maneuver, to avoid or minimize any compensatory movements, which could increase and bias the outcome. However, using two examiners to carry out the tests appears to limit the practical application of these measurement methods in the sport and clinic context. As these measurement methods are simple to perform, the role of the assistant examiner could be undertaken by any postgraduate student or athletic trainer who performs one or two 10 min training sessions (statement based on the authors’ extensive experience). The Bledsoe knee brace of Wang et al. [67] is an effective device for fixing the knee; however, its use requires extra time.
Several assessment sessions required depends directly on the type of study. Generally, scientific studies perform only one evaluation session; specifically, studies to determine the lower-limb flexibility profile [7,42,45,49,91,92] or to associate/predict athletic physical-technical performance [3,37,39,93] and risk of injury [11,12,24,83,94]. The validity and absolute reliability of scientific studies involved 2–4 assessment sessions to determine the relative or absolute reliability of an assessment battery test [58]. Moreover, studies conducted to determine the chronic effects of a flexibility program on ROM include several assessment sessions [95,96].
A single repetition reported per ROM test by different authors [12,53,67,69] does not provide the examiner with the precision or variability of measurements beyond error [58,97].
The most recommended by authors is to perform at least two repetitions o trials per ROM test [45,63,70]. For that reason, the proposal of Cejudo et al. [45,63] performs two maximal trials of each test and limb (dominant and non-dominant) in a randomized order. The mean score for each test would be considered as the final (true) ROM value. In the cases where variation is higher than 5% in the ROM values between the two trials of any test, an extra trial would be performed [45,63]. The two most closely related trials would be used to calculate the true ROM value, as long as the difference with the new trial is <5%. If this is not the case, then the examiner would be required to revise the procedure for any possible error or review the circumstances that may explain the variability.
The content validity is determined by judging if an instrument or procedure accurately measures and represents the variable of interest. In this sense, all the selected assessment tests (Table 1), including ROM-SPORT I battery tests, have been considered appropriate by the American Medical Organizations [6,76] and included in the accredited manuals of Sports Medicine and Science [6,57,82], based on anatomical knowledge and extensive clinical experience.
Studies based on a radiography method considered the standard criterion (gold standard) for measuring flexibility, report a high concordance (criterion validity or both procedures can be interchangeable) with the ROM measurement method using a goniometer or inclinometer [84,98]. Some studies have examined the criterion-related validity (mainly through correlation coefficients) of some knee and hip ROM measures recorded using different field-based tools (i.e., mainly inclinometers and goniometers) and radiography [68,75]. These ROM measures obtained through using goniometers and inclinometers have reported correlations with their respective radiography criterion measures higher than 0.80, which suggests that their use may be interchangeable [68,75,84]. Finally, studies are needed to determine the criterion-related validity of the digital motion measurement method (kinematic analysis) proposed by Bozic et al. [54] and Nussbaumer et al. [56] in accordance with the radiographic method.
All the tests represented in Table 1 displayed moderate to excellent reliability values (ICC ranging from 0.72 to 0.99) except for hip extension with knee flexion and knee extension with 90° hip flexion tests [53]. This result may possibly be due to the complex procedure of the test and evaluation methods (anatomical landmarks, hand-held dynamometer, video capture digital, and digital motion analysis software).
According to absolute reliability values, clinicians and sport practitioners can be 95% confident that an observer’s change between two measures larger than 1.3–6.9° for the ROM values obtained from the ROM-SPORT I would likely indicate a real change (determined through the statistical minimal detectable change with a 95% confidence interval.
5. Practical Guidelines
For the practical application of the ROM-SPORT I battery test, users should consider the following aspects to obtain accurate and valid measurements: (1) The majority of the tests of the ROM-SPORT I battery (9 of the 11) involve two examiners to avoid any possible compensatory movements; it reduces measurement error and may give more accurate ROM values, avoiding false diagnostic of limited ROM; (2) The inclinometer (the instrument used in the ROM-SPORT I procedure) is easy and simple to use, as it does not require the estimation of the joint’s axis nor the initial position. Also, this tool reduces measurement errors since the examiner can systematically and repeatedly locate the same position to place the inclinometer by just following the parallel imaginary bisector of the segment assessed; (3) It is recommended to use a telescopic arm to facilitate the inclinometer’s placement, which may improve the precision and reproducibility of the measurement and reduce the duration of the ROM-SPORT I battery; (4) The lower-back protection support “Lumbosant” (Imucot Traumatología SL, Murcia, Spain), used in the ROM-SPORT I battery, helps to standardize the lumbar curvature (20°) during the assessments, avoiding higher ROM values, due to anterior or posterior pelvis tilt compensatory movements.
Although this review has been focused mainly on a sports context, the ROM-SPORT I battery can also be applied in research (clinical studies, sports performance sport risk injuries, and others) and clinical fields. This battery has the following practical applications:
-
−
To accurately quantify the ROM measures of the major lower extremity joints (hip, knee, and ankle);
-
−
To identify athletes with limited or restricted joint ROM values. This knowledge may help in the decision-making process regarding the identification of athletes at high risk of sustaining an injury (mainly soft tissue injury);
-
−
To detect those athletes (e.g., rhythmic gymnasts, figure skaters, and diving) that should improve their ROM values to successfully perform the technical actions that are awarded the highest points by a judge;
-
−
To monitor the efficacy of intervention programs (e.g., stretching exercises and foam rolling) designed to maintain or improve lower extremity joints ROM;
-
−
Furthermore, in rehabilitation processes, the ROM-SPORT I battery may be used to determine if the ROM of the injured joint has been fully restored, which may help to achieve a safe return to play (athletes) or activities of daily life (general population).
6. Conclusions
Although different batteries have been used to assess ROM previously, they all have some limitations. The ROM-SPORT I battery seems to be the most complete procedure that meets the requirements of a battery of tests for the ROM assessment of the lower limbs. The novelty and new contributions of the ROM-SPORT I battery over other procedures described previously by other authors are: (1) The rapidity of the ROM-SPORT I battery. This procedure evaluates 11 tests in one athlete, including both lower limbs in 8–11 min; (2) the importance of the assistant examiner, together with using the lumbar support tool, “Lumbosant” (Imucot Traumatología SL, Murcia, Spain), to reduce compensatory movements; (3) the simplicity of the procedure. The inclinometer with an extensible rod is a simple and cheap tool that minimizes the measured variability and the error of the examiner.; (4) the validity of the ROM-SPORT I battery is based on criterion validity (radiographic) and content validity; and (5) all the ROM tests of the selected publications reported moderate to excellent reliability values; it is excellent for tests of ROM-SPORT I battery.
Author Contributions
Conceptualization, A.C., F.S.-M., P.S.d.B., F.A. and M.D.S.C.; formal analysis, A.C., F.S.-M., P.S.d.B. and F.A.; funding acquisition, A.C., F.S.-M., F.A. and P.S.d.B.; investigation, A.C., F.S.-M., P.S.d.B., F.A. and M.D.S.C.; methodology, A.C., F.S.-M., F.A. and P.S.d.B.; project administration, P.S.d.B. and A.C.; resources, A.C., F.S.-M., and P.S.d.B.; supervision, A.C., F.S.-M., M.D.S.C. and P.S.d.B.; writing—original draft, A.C., F.S.-M., P.S.d.B., F.A. and M.D.S.C.; writing—review and editing, A.C., F.S.-M., P.S.d.B., F.A. and M.D.S.C. All authors have read and agreed to the published version of the manuscript.
Funding
This study is part of the project entitled “Estudio del riesgo de lesión en jóvenes deportistas a través de redes de inteligencia artificial”, funded by the Spanish Ministry of Science and Innovation (DEP2017-88775-P), the State Research Agency (AEI) and the European Regional Development Fund (ERDF). This study was conducted during the research stay at the School of Sport and Exercise at the University of Gloucestershire (United Kingdom) from 25/11/2019 to 29/01/2020 (A.C.). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Conflicts of Interest
The authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, or in the decision to publish the results.
Footnotes
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Holt L., Pelham T., Holt J. Flexibility: A Concise Guide To Conditioning, Performance Enhancement, Injury Prevention, and Rehabilitation. Humana Press; Totowa, NJ, USA: 2009. [Google Scholar]
- 2.Magnusson P., Renström P. The European College of Sports Sciences position statement: The role of stretching exercises in sports. Eur. J. Sport Sci. 2006;6:87–91. doi: 10.1080/17461390600617865. [DOI] [Google Scholar]
- 3.García-Pinillos F., Ruiz-Ariza A., Moreno del Castillo R., Latorre-Román P. Impact of limited hamstring flexibility on vertical jump, kicking speed, sprint, and agility in young football players. J. Sports Sci. 2015;33:1293–1297. doi: 10.1080/02640414.2015.1022577. [DOI] [PubMed] [Google Scholar]
- 4.Hahn T., Foldspang A., Vestergaard E., Ingemann-Hansen T. Active knee joint flexibility and sports activity. Scand. J. Med. Sci. Sports. 1999;9:74–80. doi: 10.1111/j.1600-0838.1999.tb00212.x. [DOI] [PubMed] [Google Scholar]
- 5.De la Fuente A., Gómez-Landero L. Motor differences in cadet taekwondo athletes according to competition level. Rev. Int. Med. Cienc. Act. Fis. Deport. 2019;19:63–75. doi: 10.15366/rimcafd2019.73.005. [DOI] [Google Scholar]
- 6.Gerhardt J., Cocchiarella L., Lea R. The Practical Guide to Range of Motion Assessment. American Medical Association; Chicago, IL, USA: 2002. [Google Scholar]
- 7.Cejudo A., Robles-Palazón F., Sainz De Baranda P. Fútbol sala de élite: Diferencias de flexibilidad según sexo. E-Balonmano.com Rev. Cienc. Deport. 2019;15:37–48. [Google Scholar]
- 8.Verrall G., Slavotinek J., Barnes P., Esterman A., Oakeshott R., Spriggins A. Hip joint range of motion restriction precedes athletic chronic groin injury. J. Sci. Med. Sport. 2007;10:463–466. doi: 10.1016/j.jsams.2006.11.006. [DOI] [PubMed] [Google Scholar]
- 9.Arnason A., Sigurdsson S., Gudmundsson A., Holme I., Engebretsen L., Bahr R. Risk Factors for Injuries in Football. Am. J. Sports Med. 2004;32(Suppl. S1):5S–16S. doi: 10.1177/0363546503258912. [DOI] [PubMed] [Google Scholar]
- 10.Ibrahim A., Murrell G., Knapman P. Adductor Strain and Hip Range of Movement in Male Professional Soccer Players. J. Orthop. Surg. 2007;15:46–49. doi: 10.1177/230949900701500111. [DOI] [PubMed] [Google Scholar]
- 11.Shah S., Testa E., Gammal I., Sullivan J., Gerland R., Goldstein J., Cohn R. Hip Range of Motion: Which Plane of Motion Is More Predictive of Lower Extremity Injury in Elite Soccer Players? A Prospective Study. J. Surg. Orthop. Adv. 2019;28:201–208. [PubMed] [Google Scholar]
- 12.Witvrouw E., Danneels L., Asselman P., D’Have T., Cambier D. Muscle flexibility as a risk factor for developing muscle injuries in male professional soccer players: A prospective study. Am. J. Sports Med. 2003;31:41–46. doi: 10.1177/03635465030310011801. [DOI] [PubMed] [Google Scholar]
- 13.Okamura S., Wada N., Tazawa M., Sohmiya M., Ibe Y., Shimizu T., Usuda S., Shirakura K. Injuries and disorders among young ice skaters: Relationship with generalized joint laxity and tightness. Open Access J. Sport. Med. 2014;5:191–195. doi: 10.2147/OAJSM.S63540. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Witvrouw E., Bellemans J., Lysens R., Danneels L., Cambier D. Intrinsic Risk Factors for the Development of Patellar Tendinitis in an Athletic Population. Am. J. Sports Med. 2001;29:190–195. doi: 10.1177/03635465010290021201. [DOI] [PubMed] [Google Scholar]
- 15.VandenBerg C., Crawford E., Enselman E., Robbins B., Wojtys E., Bedi A. Restricted Hip Rotation Is Correlated With an Increased Risk for Anterior Cruciate Ligament Injury. Arthrosc. J. Arthrosc. Relat. Surg. 2017;33:317–325. doi: 10.1016/j.arthro.2016.08.014. [DOI] [PubMed] [Google Scholar]
- 16.Murray E., Birley E., Twycross-Lewis R., Morrissey D. The relationship between hip rotation range of movement and low back pain prevalence in amateur golfers: An observational study. Phys. Ther. Sport. 2009;10:131–135. doi: 10.1016/j.ptsp.2009.08.002. [DOI] [PubMed] [Google Scholar]
- 17.Sainz de Baranda P., Cejudo A., Ayala F., Santonja F. Perfil óptimo de flexibilidad del miembro inferior en jugadoras de fútbol sala. Rev. Int. Med. Cienc. Act. Fis. Deport. 2015;15:647–662. doi: 10.15366/rimcafd2015.60.003. [DOI] [Google Scholar]
- 18.Vad V., Bhat A., Basrai D., Gebeh A., Aspergren D., Andrews J. Low Back Pain in Professional Golfers: The Role of Associated Hip and Low Back Range-of-Motion Deficits. Am. J. Sports Med. 2004;32:494–497. doi: 10.1177/0363546503261729. [DOI] [PubMed] [Google Scholar]
- 19.Witvrouw E., Van Tiggelen D., Willems T. Anterior Knee Pain and Patellar Instability. Springer; London, UK: 2005. Risk factors and prevention of anterior knee pain; pp. 135–145. [DOI] [Google Scholar]
- 20.Koga H., Nakamae A., Shima Y., Bahr R., Krosshaug T. Hip and Ankle Kinematics in Noncontact Anterior Cruciate Ligament Injury Situations Video Analysis Using Model-Based Image Matching. Am. J. Sports Med. 2018;46:333–340. doi: 10.1177/0363546517732750. [DOI] [PubMed] [Google Scholar]
- 21.McLean S., Walker K., van den Bogert A., den Bogert V. Effect of Gender on Lower Extremity Kinematics during Rapid Direction Changes: An Integrated Analysis of Three Sports Movements. J. Sci. Med. Sport. 2005;8:411–422. doi: 10.1016/S1440-2440(05)80056-8. [DOI] [PubMed] [Google Scholar]
- 22.Herrington L. Knee valgus angle during single leg squat and landing in patellofemoral pain patients and controls. Knee. 2014;21:514–517. doi: 10.1016/j.knee.2013.11.011. [DOI] [PubMed] [Google Scholar]
- 23.Kawałek K., Garsztka T. An analysys of muscle balance in professional field hockey players. TRENDS Sport Sci. 2013;4:181–187. [Google Scholar]
- 24.Cejudo A., Moreno-Alcaraz V.J., Izzo R., Santonja-Medina F., Sainz de Baranda P. External and Total Hip Rotation Ranges of Motion Predispose to Low Back Pain in Elite Spanish Inline Hockey Players. Int. J. Environ. Res. Public Health. 2020;17:4858. doi: 10.3390/ijerph17134858. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Butler D., Moseley G. Explain Pain Course Description. 2nd ed. Noigroup publications; Adelaide, Australia: 2013. [Google Scholar]
- 26.Fridén J., Lieber R. Eccentric exercise-induced injuries to contractile and cytoskeletal muscle fibre components. Acta Physiol. Scand. 2001;171:321–326. doi: 10.1046/j.1365-201X.2001.00834.x. [DOI] [PubMed] [Google Scholar]
- 27.Worrell T., Perrin D. Hamstring muscle injury: The influence of strength, flexibility, warm-up, and fatigue. J. Orthop. Sports Phys. Ther. 1992;16:12–18. doi: 10.2519/jospt.1992.16.1.12. [DOI] [PubMed] [Google Scholar]
- 28.Battista R., Pivarnik J., Dummer G., Sauer N., Malina R. Comparisons of physical characteristics and performances among female collegiate rowers. J. Sports Sci. 2007;25:651–657. doi: 10.1080/02640410600831781. [DOI] [PubMed] [Google Scholar]
- 29.Sánchez-Sánchez J., Pérez A., Boada P., García M., Moreno C., Carretero M. Estudio de la flexibilidad de luchadores de kickboxing de nivel internacional. Arch. Med. Deport. 2014;31:85–91. [Google Scholar]
- 30.Newlands C., Reid D., Parmar P. The prevalence, incidence and severity of low back pain among international-level rowers. Artic. Br. J. Sport. Med. 2015;49:951–956. doi: 10.1136/bjsports-2014-093889. [DOI] [PubMed] [Google Scholar]
- 31.Wattie N., Cobley S., Macpherson A., Howard A., Montelpare W., Baker J. Injuries in Canadian youth ice hockey: The influence of relative age. Pediatrics. 2007;120:142–148. doi: 10.1542/peds.2006-2672. [DOI] [PubMed] [Google Scholar]
- 32.Lee A., Garraway M. Epidemiological comparison of injuries in school and senior club rugby. Br. J. Sport. Med. 1996;30:213–217. doi: 10.1136/bjsm.30.3.213. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Orchard J., Wood T., Seward H., Broad A. Comparison of injuries in elite senior and junior Australian football. J. Sci. Med. Sport. 1998;1:83–88. doi: 10.1016/S1440-2440(98)80016-9. [DOI] [PubMed] [Google Scholar]
- 34.Hogg J., Schmitz R., Nguyen A., Shultz S. Lumbo-Pelvic-Hip Complex Passive Hip Range-of-Motion Values Across Sex and Sport. J. Athl. Train. 2018;53:560–567. doi: 10.4085/1062-6050-426-16. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35.Moreno A., Gómez E., Martín A. Valoración de la flexibilidad de tronco mediante el test del cajón en diferentes modalidades deportivas. Sel. Rev. Esp. Iberoam. Med. Educ. Fis. Deport. 2004;13:148–154. [Google Scholar]
- 36.Kang M.-H., Park K.-H., Oh J.-S. Association of Ankle Kinematics and Performance on the Y-Balance Test with Inclinometer Measurements on the Weight-Bearing-Lunge Test. J. Sport Rehabil. 2015;24:62–67. doi: 10.1123/jsr.2013-0117. [DOI] [PubMed] [Google Scholar]
- 37.Aslan H., Buddhadev H., Suprak D., San Juan J. Acute effects of two hip flexor stretching techniques on knee joint position sense and balance. Int. J. Sports Phys. Ther. 2018;13:846–859. doi: 10.26603/ijspt20180846. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Lee E., Etnyre B., Poindexter H., Sokol D., Toon T. Flexibility characteristics of elite female and male volleyball players. J. Sports Med. Phys. Fit. 1989;29:49–51. [PubMed] [Google Scholar]
- 39.Faiss R., Terrier P., Praz M., Fuchslocher J., Gobelet C., Deriaz O. Influence of Initial Foot Dorsal Flexion on Vertical Jump and Running Performance. Artic. J. Strength Cond. Res. 2009;24:2352–2357. doi: 10.1519/JSC.0b013e3181aff2cc. [DOI] [PubMed] [Google Scholar]
- 40.Cejudo A., Sainz De Baranda P., Ayala F., Santonja F. Normative data of lower-limb muscle flexibility in futsal players. Rev. Int. Med. Cienc. Act. Fis. Deport. 2014;14:509–525. [Google Scholar]
- 41.Chandler T., Kibler W., Uhl T., Wooten B., Kiser A., Stone E. Flexibility comparisons of junior elite tennis players to other athletes. Am. J. Sports Med. 1990;18:134–136. doi: 10.1177/036354659001800204. [DOI] [PubMed] [Google Scholar]
- 42.Cejudo A., Moreno-Alcaraz V.J., Croix M.D.S., Santonja-Medina F., Sainz de Baranda P. Lower-Limb Flexibility Profile Analysis in Youth Competitive Inline Hockey Players. Int. J. Environ. Res. Public Health. 2020;17:4338. doi: 10.3390/ijerph17124338. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.Oberg B., Ekstrand J., Moller M., Gillquist J. Muscle strength and flexibility in different positions of soccer players. Int. J. Sports Med. 1984;5:213–216. doi: 10.1055/s-2008-1025908. [DOI] [PubMed] [Google Scholar]
- 44.Bloomfield J., Polman R., O´Donoghue P. Physical demands of different positions in FA Premier League soccer. J. Sport. Sci. Med. 2007;6:63–70. [PMC free article] [PubMed] [Google Scholar]
- 45.Cejudo A., Robles-Palazón F., Ayala F., De Ste Croix M., Ortega-Toro E., Santonja F., Sainz de Baranda P. Age-related differences in flexibility in soccer players 8-19 years old. PeerJ. 2019;2019:e6236. doi: 10.7717/peerj.6236. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46.Ellenbecker T., Ellenbecker G., Roetert E., Silva R., Keuter G., Sperling F. Descriptive profile of hip rotation range of motion in elite tennis players and professional baseball pitchers. Am. J. Sports Med. 2007;35:1371–1376. doi: 10.1177/0363546507300260. [DOI] [PubMed] [Google Scholar]
- 47.Bittencourt N., Ocarino J., Sorrentino F., Jales F., Gabriel S., Mendonça L., Fonseca S. Normative data for muscle flexibility in male soccer players. Br. J. Sports Med. 2014;48:568–569. doi: 10.1136/bjsports-2014-093494.24. [DOI] [Google Scholar]
- 48.Gannon L., Bird H., Gan Non L. The quantification of joint laxity in dancers and gymnasts The quantification of joint laxity in dancers and gymnasts. J. Sports Sci. 1999;17:743–750. doi: 10.1080/026404199365605. [DOI] [PubMed] [Google Scholar]
- 49.Cejudo A. El perfil óptimo de flexibilidad en jóvenes jugadores de fútbol durante su periodo sensible del desarrollo físico. Batería ROM-SPORT. JUMP. 2020;2:16–25. doi: 10.17561/jump.n2.2. [DOI] [Google Scholar]
- 50.Bradley P., Portas M. The relationship between preseason range of motion and muscle strain injury in elite soccer players. J. Strength Cond. Res. 2007;21:1155–1159. doi: 10.1519/R-20416.1. [DOI] [PubMed] [Google Scholar]
- 51.Gabbe B., Bennell K., Wajswelner H., Finch C. Reliability of common lower extremity musculoskeletal screening tests. Phys. Ther. Sport. 2004;5:90–97. doi: 10.1016/S1466-853X(04)00022-7. [DOI] [Google Scholar]
- 52.Cejudo A., Moreno-Alcaraz V.J., Izzo R., Robles-Palazón F.J., Sainz de Baranda P., Santonja-Medina F. Flexibility in Spanish Elite Inline Hockey Players: Profile, Sex, Tightness and Asymmetry. Int. J. Environ. Res. Public Health. 2020;17:3295. doi: 10.3390/ijerph17093295. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 53.Fourchet F., Materne O., Horobeanu C., Hudacek T., Buchheit M. Reliability of a novel procedure to monitor the flexibility of lower limb muscle groups in highly-trained adolescent athletes. Phys. Ther. Sport. 2013;14:28–34. doi: 10.1016/j.ptsp.2012.02.004. [DOI] [PubMed] [Google Scholar]
- 54.Bozic P., Pazin N., Berjan B., Planic N., Cux I. Evaluation of the field tests of flexibility of the lower extremity: Reliability and the concurrent and factorial validity. J. Strength Cond. Res. 2010;24:2523–2531. doi: 10.1519/JSC.0b013e3181def5e4. [DOI] [PubMed] [Google Scholar]
- 55.Ekstrand J., Gillquist J. The frequency of muscle tightness and injuries in soccer players. Am. J. Sports Med. 1982;10:75–78. doi: 10.1177/036354658201000202. [DOI] [PubMed] [Google Scholar]
- 56.Nussbaumer S., Leunig M., Glatthorn J., Stauffacher S., Gerber H., Maffiuletti N. Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients. BMC Musculoskelet. Disord. 2010;11:194. doi: 10.1186/1471-2474-11-194. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 57.Norkin C., White D. Measurement of Joint Motion: A Guide to Goniometry. FA Davis; Philadelphia, PA, USA: 2016. [Google Scholar]
- 58.Hopkins W., Marshall S., Batterham A., Hanin J. Progressive Statistics for Studies in Sports Medicine and Exercise Science. Med. Sci. Sport. Exerc. 2009;41:3–12. doi: 10.1249/MSS.0b013e31818cb278. [DOI] [PubMed] [Google Scholar]
- 59.Hopkins W. How to interpret changes in an athletic performance test. Sport Sci. 2004;8:1–7. [Google Scholar]
- 60.Cejudo A. Ph.D. Thesis. Universidad de Murcia; Murcia, Spain: 2015. Deporte y Flexibilidad: Rendimiento Deportivo sin Riesgo de Lesión. [Google Scholar]
- 61.Sainz De Baranda P., Cejudo A., Ayala F., Santonja F. Perfil de flexibilidad de la extremidad inferior en jugadoras senior de fútbol sala. Rev. Esp. Educ. Fis. Deport. 2015;409:35–48. [Google Scholar]
- 62.Moher D., Liberati A., Tetzlaff J., Altman D.G., Altman D., Antes G., Atkins D., Barbour V., Barrowman N., Berlin J.A., et al. Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement. PLoS Med. 2009;6:e1000097. doi: 10.1371/journal.pmed.1000097. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 63.Cejudo A., Sainz de Baranda P., Ayala F., Santonja F. Test-retest reliability of seven common clinical tests for assessing lower extremity muscle flexibility in futsal and handball players. Phys. Ther. Sport. 2015;16:107–113. doi: 10.1016/j.ptsp.2014.05.004. [DOI] [PubMed] [Google Scholar]
- 64.Möller M., Öberg B., Gillquist J. Effect of Stretching on Range of Motion in the Lower Extremity in Connection with Soccer Training. Int. J. Sports Med. 1985;6:50–52. doi: 10.1055/s-2008-1025813. [DOI] [PubMed] [Google Scholar]
- 65.Reid D.C., Burnham R.S., Saboe L.A., Kushner S.F. Lower extremity flexibility patterns in classical ballet dancers and their correlation to lateral hip and knee injuries. Am. J. Sports Med. 1987;15:347–352. doi: 10.1177/036354658701500409. [DOI] [PubMed] [Google Scholar]
- 66.Clapper M., Wolf S. Comparison of the reliability of the Orthoranger and the standard goniometer for assessing active lower extremity range of motion. Phys. Ther. 1988;68:214–218. doi: 10.1093/ptj/68.2.214. [DOI] [PubMed] [Google Scholar]
- 67.Wang S., Whitney S., Burdett R., Janosky J. Lower extremity muscular flexibility in long distance runners. J. Orthop. Sports Phys. Ther. 1993;17:102–107. doi: 10.2519/jospt.1993.17.2.102. [DOI] [PubMed] [Google Scholar]
- 68.Gogia P., Braatz J., Rose S., Norton B. Reliability and Validity of Goniometric Measurements at the Knee. Phys. Ther. 1987;67:192–195. doi: 10.1093/ptj/67.2.192. [DOI] [PubMed] [Google Scholar]
- 69.Steinberg N., Hershkovitz I., Peleg S., Dar G., Masharawi Y., Heim M., Siev-Ner I. Range of joint movement in female dancers and nondancers aged 8 to 16 years: Anatomical and clinical implications. Am. J. Sports Med. 2006;34:814–823. doi: 10.1177/0363546505281805. [DOI] [PubMed] [Google Scholar]
- 70.Pua Y., Wrigley T., Cowan S., Bennell K. Intrarater test-retest reliability of hip range of motion and hip muscle strength measurements in persons with hip osteoarthritis. Arch. Phys. Med. Rehabil. 2008;89:1146–1154. doi: 10.1016/j.apmr.2007.10.028. [DOI] [PubMed] [Google Scholar]
- 71.Tainaka K., Takizawa T., Kobayashi H., Umimura M. Limited hip rotation and non-contact anterior cruciate ligament injury: A case–control study. Knee. 2014;21:86–90. doi: 10.1016/j.knee.2013.07.006. [DOI] [PubMed] [Google Scholar]
- 72.Cejudo A., Ayala F., Sainz de Baranda P., Santonja F. Reliability of two methods of clinical examination of the flexibility of the hip adductor muscles. Int. J. Sports Phys. Ther. 2015;10:976–983. [PMC free article] [PubMed] [Google Scholar]
- 73.Grazette N., McAllister S., Ong C.W., Sunderland C., Nevil M.E., Morri J.G. Reliability of a musculoskeletal profiling test battery in elite academy soccer players. PLoS ONE. 2020;15:e0236341. doi: 10.1371/journal.pone.0236341. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 74.Ekstrand J., Wiktorsson M., Oberg B., Gillquist J. Lower extremity goniometric measurements: A study to determine their reliability. Arch. Phys. Med. Rehabil. 1982;63:171–175. [PubMed] [Google Scholar]
- 75.Enwemeka C. Radiographic verification of knee goniometry. Scand. J. Rehabil. Med. 1986;18:47–49. [PubMed] [Google Scholar]
- 76.Greene W., Heckman J. Clinical Assessment of Joint Movement. Edika Med.; Barcelona, Spain: 1997. [Google Scholar]
- 77.Hopkins W. Measures of Reliability in Sports Medicine and Science. Sport. Med. 2000;30:1–15. doi: 10.2165/00007256-200030010-00001. [DOI] [PubMed] [Google Scholar]
- 78.McHugh M., Cosgrave C. To stretch or not to stretch: The role of stretching in injury prevention and performance. Scand. J. Med. Sci. Sports. 2009;20:169–181. doi: 10.1111/j.1600-0838.2009.01058.x. [DOI] [PubMed] [Google Scholar]
- 79.Iwata M., Yamamoto A., Matsuo S., Hatano G., Miyazaki M., Fukaya T., Fujiwara M., Asai Y., Suzuki S. Dynamic Stretching Has Sustained Effects on Range of Motion and Passive Stiffness of the Hamstring Muscles. J. Sport. Sci. Med. 2019;18:13–20. [PMC free article] [PubMed] [Google Scholar]
- 80.Magnusson S., Simonsen E., Aagaard P., Gleim G., McHugh M., Kjaer M. Viscoelastic response to repeated static stretching in the human hamstring muscle. Scand. J. Med. Sci. Sports. 1995;5:342–347. doi: 10.1111/j.1600-0838.1995.tb00056.x. [DOI] [PubMed] [Google Scholar]
- 81.Ayala F., Moreno-Perez V., Vera-Garcia F., Moya M., Sanz-Rivas D., Fernandez-Fernandez J. Acute and time-course effects of traditional and dynamic warm-up routines in young elite junior tennis players. PLoS ONE. 2016;11:e0152790. doi: 10.1371/journal.pone.0152790. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 82.Magee D. Orthopedic Physical Assessment. Elsevier Health Sciences; Philadelphia, PA, USA: 2013. [Google Scholar]
- 83.Cejudo A., Ginés-Díaz A., Sainz de Baranda P. Asymmetry and Tightness of Lower Limb Muscles in Equestrian Athletes: Are They Predictors for Back Pain? Symmetry (Basel) 2020;12:1679. doi: 10.3390/sym12101679. [DOI] [Google Scholar]
- 84.Santonja-Medina F., Santonja-Renedo S., Cejudo A., Ayala F., Ferrer V., Pastor A., Collazo-Diéguez M., Rodríguez-Ferrán O., Andújar P., Sainz de Baranda P. Straight Leg Raise Test: Influence of Lumbosant© and Assistant Examiner in Hip, Pelvis Tilt and Lumbar Lordosis. Symmetry (Basel) 2020;12:927. doi: 10.3390/sym12060927. [DOI] [Google Scholar]
- 85.Bohannon R., Gajdosik R., Leveau B. Contribution of pelvic and lower limb motion to increases in the angle of passive straight leg raising. Phys. Ther. 1985;65:474–476. doi: 10.1093/ptj/65.4.474. [DOI] [PubMed] [Google Scholar]
- 86.Cameron D., Bohannon R., Owen S. Influence of hip position on measurements of the straight leg raise test. J. Orthop. Sports Phys. Ther. 1994;19:168–172. doi: 10.2519/jospt.1994.19.3.168. [DOI] [PubMed] [Google Scholar]
- 87.Cejudo A., Sainz De Baranda P., Ayala F., Santonja F. A simplified version of the weight-bearing ankle lunge test: Description and test-retest reliability. Man. Ther. 2014;19:355–359. doi: 10.1016/j.math.2014.03.008. [DOI] [PubMed] [Google Scholar]
- 88.Fredriksen H., Dagfinrud H., Jacobsen V., Maehlum S. Passive knee extension test to measure hamstring muscle tightness. Scand. J. Med. Sci. Sports. 1997;7:279–282. doi: 10.1111/j.1600-0838.1997.tb00153.x. [DOI] [PubMed] [Google Scholar]
- 89.Ayala F., Sainz de Baranda P., De Ste Croix M., Santonja F. Reproducibility and criterion-related validity of the sit and reach test and toe touch test for estimating hamstring flexibility in recreationally active young adults. Phys. Ther. Sport. 2012;13:219–226. doi: 10.1016/j.ptsp.2011.11.001. [DOI] [PubMed] [Google Scholar]
- 90.Gómez-Jiménez F., Ayala F., Cejudo A., Sainz de Baranda P., Santonja F. Efecto del nivel de experiencia clínica del examinador sobre la validez de criterio y fiabilidad inter-sesión de cinco medidas del rango de movimiento de la flexión. Cuad. Psicol. del Deport. 2015;15:123–134. doi: 10.4321/S1578-84232015000300012. [DOI] [Google Scholar]
- 91.Robles-Palazón F., Ayala F., Cejudo A., De Ste Croix M., Sainz de Baranda P., Santonja F. Effects of age and maturation on lower extremity range of motion in male youth soccer players. J. Strength Cond. Res. 2020 doi: 10.1519/JSC.0000000000003642. [DOI] [PubMed] [Google Scholar]
- 92.López-Valenciano A., Ayala F., Vera-García F., De Ste Croix M., Hernández-Sánchez S., Ruiz-Pérez I., Cejudo A., Santonja F. Comprehensive profile of hip, knee and ankle ranges of motion in professional football players. J. Sports Med. Phys. Fit. 2019;59:102–109. doi: 10.23736/S0022-4707.17.07910-5. [DOI] [PubMed] [Google Scholar]
- 93.Rey E., Padrón-Cabo A., Barcala-Furelos R., Mecías-Calvo M. Effect of High and Low Flexibility Levels on Physical Fitness and Neuromuscular Properties in Professional Soccer Players. Int. J. Sports Med. 2016;37:878–883. doi: 10.1055/s-0042-109268. [DOI] [PubMed] [Google Scholar]
- 94.Fousekis K., Tsepis E., Poulmedis P., Athanasopoulos S., Vagenas G. Intrinsic risk factors of non-contact quadriceps and hamstring strains in soccer: A prospective study of 100 professional players. Br. J. Sports Med. 2011;45:709–714. doi: 10.1136/bjsm.2010.077560. [DOI] [PubMed] [Google Scholar]
- 95.Ayala F., Sainz de Baranda P., De Ste Croix M., Santonja F. Comparison of active stretching technique in males with normal and limited hamstring flexibility. Phys. Ther. Sport. 2013;14:98–104. doi: 10.1016/j.ptsp.2012.03.013. [DOI] [PubMed] [Google Scholar]
- 96.Santonja F., Sainz De Baranda P., García P., López-Miñarro P., Jordana M. Effects of frequency of static stretching on straight-leg raise in elementary school children. J. Sport. Med. Phys. Fit. 2007;47:304–308. [PubMed] [Google Scholar]
- 97.Weir J.P. Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. J. Strength Cond. Res. 2005;19:231–240. doi: 10.1519/15184.1. [DOI] [PubMed] [Google Scholar]
- 98.Perret C., Poiraudeau S., Fermanian J., Colau M., Benhamou M., Revel M. Validity, reliability, and responsiveness of the fingertip-to-floor test. Arch. Phys. Med. Rehabil. 2001;82:1566–1570. doi: 10.1053/apmr.2001.26064. [DOI] [PubMed] [Google Scholar]