Abstract
Purpose
To investigate the impact of respiratory motion in the treatment margins for lung SBRT frameless treatments and to validate our treatment margins using 4D CBCT data analysis.
Methods
Two hundred and twenty nine fractions with early stage NSCLC were retrospectively analyzed. All patients were treated in frameless and free breathing conditions. The treatment margins were calculated according to van Herk equation in Mid‐Ventilation. For each fraction, three 4D CBCT scans, pre‐ and postcorrection, and posttreatment, were acquired to assess target baseline shift, target localization accuracy and intra‐fraction motion errors. A bootstrap analysis was performed to assess the minimum number of patients required to define treatment margins.
Results
The retrospectively calculated target‐baseline shift, target localization accuracy and intra‐fraction motion errors agreed with the literature. The best tailored margins to our cohort of patients were retrospectively computed and resulted in agreement with already published data. The bootstrap analysis showed that fifteen patients were enough to assess treatment margins.
Conclusions
The treatment margins applied to our patient’s cohort resulted in good agreement with the retrospectively calculated margins based on 4D CBCT data. Moreover, the bootstrap analysis revealed to be a promising method to verify the reliability of the applied treatment margins for safe lung SBRT delivery.
Keywords: 4D CBCT, 4D CT, breathing motion, bootstrap, margins
1. INTRODUCTION
The application of the Stereotactic Body Radiation Therapy (SBRT) to the lung is a complicated scenario because respiratory‐induced tumor motion has an impact on the target localization and thus influences the accuracy of imaging, treatment planning, and treatment delivery. 1 One way to reduce these uncertainties is to use a respiratory‐correlated CT scan (4D CT) 2 , 3 , 4 , 5 , 6 , 7 at the treatment preparation stage and to perform 4D cone beam CT (4D‐CBCT) prior to treatment, as both techniques provide 3D images at multiple phases of the respiratory cycle. For lung SBRT in free breathing conditions, a moving organ can be treated using the Mid‐Ventilation approach (Mid‐V), 8 , 9 in which the predominant breathing phase closest to the time‐weighted mean tumor position is selected for the planning, thus ensuring small treatment margins. However, when calculating dose and appropriate margins for lung SBRT, motion, baseline shifts and low‐density media must also be considered. Van Herk et al 10 proposed a probabilistic approach to create the margins. The key of this approach is to include the systematic and random errrors based on clinical practice when computing the margins, in order to ensure adequate tumor dose coverage for a high percentage of patients. The systematic and random errors for lung tumors can be defined by statistical analysis of the distribution of changes in tumor position during a course of radiotherapy. Therefore, the 4D CBCT 11 makes it possible to assess, prior to each fraction treatment, the mean position and the 3D trajectory of the tumor, and then to verify the applied treatment margins on a daily basis. Moreover, breathing‐related variations in tumor positions can appear during the treatment intra‐ and inter‐fractionally. The intra‐fraction variation describes the variation in the tumor position during one treatment fraction, 12 , 13 , 14 while the inter‐fraction variation describes the variation of the tumor position between fractions. These two types of tumor motion variations are mainly manifested as tumor baseline shifts and introduce additional errors in the treatment. For this reason, 4D CBCT images taken at different moments in the treatment session are an appropriate way to quantify such errors; they also allows to track the 3D trajectory of the tumor, therefore veryfing the applied treatment margins on a daily basis. Within this context, the van Herk approach is commonly used to prospectively define setup margins for lung SBRT. However, this approach relies on statistical analysis of prospective data, assuming that no changes in the process occurs in the future. In this paper we propose two approaches that proactively re‐examines the margins when the process is changed by a modification in contention, treatment technique, etc. In those cases, it is indeed crucial to verify the applied margins to ensure safe SBRT delivery.
2. MATERIAL AND METHODS
2.1. Patients
Thirty patients (for a total of 229 fractions) with lower (n = 6), upper (n = 9) and mid‐lobe lesions (n = 15) and stage T1‐T2 nonsmall‐cell lung cancer were treated with SBRT. For each patient, a planning CT was acquired (16‐slices Aquilion LB; Toshiba, Japan) using a 4D acquisition protocol. Ten respiratory phases were retrospectively reconstructed from the 4D CT with the phase sorting algorithm. All patients were scanned in head‐first supine position using an arm and knee support. No additional immobilization devices were used, and none of the patients received any instructions for regular breathing before scan and treatment. The tumor motion characteristics, described as amplitude and trajectory, were assessed in the three directions. To determine the Mid‐V phase, 10 GTVs were contoured on the ten phases and the center of the mass of the GTV was determined for each phase. The phase providing the minimum distance between the center of mass of the GTV on each phase and the average center of mass of the GTV among the ten phases was selected as the Mid‐V phase. Once the Mid‐V 9 phase was identified then it was used for the delineation of the tumor and organs at risk as well as treatment planning. The patient‐specific tumor motion characteristic was used to calculate planning target volume (PTV) margins, with the van Herk equation. 10
2.2. Target volumes and planning
The Gross Target Volume (GTV) was delineated on the Mid‐V phase, in the Velocity software™ version 2.8 (Varian Medical Systems, USA), using a pulmonary level window (WW: 1224; WL: −412). No margins for microscopic extension were added to the GTV to form a Clinical Target Volume (CTV). 15 The PTV was created by applying margins to the GTV based on the van Herk equation 10 (see Margins section). The fractionation schemes were 12 x 5 Gy (n = 3), 5 × 12 Gy (n = 6), 8 × 7.5 Gy (n = 20) and 3 × 18 Gy (n = 1) depending on the tumor size and localization. All patients were planned with MONACO Monte Carlo‐based Treatment Planning System (TPS) (Elekta, Sweden) for Volumetric Modulated Arc Therapy (VMAT) delivery. Plans were prepared for a single arc or two arc VMAT deliveries depending on the patient anatomy.
2.3. Target motion assessment
Target motion amplitude was individually quantified for all patients before the start of the treatment (Table 1). The amplitude of the target measured from the 4D CT was defined as the maximum coordinates minus the minimum coordinates of the target centroid in the left‐right (LR), cranial‐caudal (CC), and anterior‐posterior (AP) directions. The 3D scalar amplitude was defined as the distance in 3D coordinates and calculated as . The 4D CT parameters were 120 kV, 150 mA, a detector width of 320 mm and a rotation time of 0.5 seconds. The pitch was less than 0.1 in order to ensure that at least one complete respiratory cycle was included in the scan acquisition. 16 Images were reconstructed with 2 mm slice thickness and 2 mm slice separation. The respiratory signal was tracked with the AZ‐733 V ANZAI belt (ANZAI Medical Solutions, Japan) measuring the variation of pressure on the belt generated by the breathing motion. Ten respiratory breathing phases were sorted retrospectively.
Table 1.
Target motion amplitude at 4D CT.
| # Patient | LR [cm] | AP [cm] | SI [cm] | 3D [cm] |
|---|---|---|---|---|
| 1 | 0.2 | 0.2 | 0.06 | 0.29 |
| 2 | 0.21 | 0.43 | 0.37 | 0.6 |
| 3 | 0.09 | 0.46 | 1.32 | 1.4 |
| 4 | 0.04 | 0.14 | 0.55 | 0.57 |
| 5 | 0.12 | 0.25 | 1 | 1.04 |
| 6 | 0.4 | 0.39 | 0.2 | 0.59 |
| 7 | 0.12 | 0.23 | 0.1 | 0.28 |
| 8 | 0.1 | 0.19 | 0.27 | 0.34 |
| 9 | 0.11 | 0.22 | 0.2 | 0.32 |
| 10 | 0.26 | 0.26 | 0.12 | 0.39 |
| 11 | 0.11 | 0.34 | 0.8 | 0.88 |
| 12 | 0.32 | 0.21 | 0.2 | 0.43 |
| 13 | 0.12 | 0.38 | 0.2 | 0.45 |
| 14 | 0.25 | 0.51 | 0.4 | 0.69 |
| 15 | 0.13 | 0.27 | 0.2 | 0.36 |
| 16 | 0.21 | 0.32 | 0.67 | 0.77 |
| 17 | 0.28 | 0.37 | 0.3 | 0.55 |
| 18 | 0.65 | 0.64 | 0.4 | 1 |
| 19 | 0.22 | 0.23 | 0.35 | 0.47 |
| 20 | 0.09 | 0.22 | 1.39 | 1.41 |
| 21 | 0.1 | 0.2 | 0.33 | 0.4 |
| 22 | 0.11 | 0.33 | 1.2 | 1.25 |
| 23 | 0.28 | 0.26 | 0.6 | 0.71 |
| 24 | 0.1 | 0.2 | 1.18 | 1.2 |
| 25 | 0.22 | 0.21 | 1.2 | 1.24 |
| 26 | 0.21 | 0.11 | 2.2 | 2.21 |
| 27 | 0.59 | 0.19 | 0.08 | 0.62 |
| 28 | 0.43 | 0.21 | 0.6 | 0.77 |
| 29 | 0.16 | 0.17 | 0.26 | 0.35 |
| 30 | 0.28 | 0.25 | 0.34 | 0.51 |
Abbreviations: AP, Anterior‐Posterior target motion amplitude; LR, Left‐Right target motion amplitude; SI, Superior‐Inferior target motion amplitude.
2.4. On‐line 4D CBCT for target localization and motion characterization
Image Guided Radiotherapy (IGRT) and treatment were performed on an Elekta Synergy linear accelerator with integrated CBCT scanner (Elekta, Sweden). Each patient was positioned with the arm and knee support used for the planning CT and aligned to the room lasers. A pretreatment 4D CBCT 17 scan was acquired. The average 4D CBCT was registered to the primary image Mid‐V using XVI software v 4.5 (Elekta, Sweden); an automatic rigid registration of the bony anatomy (i.e. vertebrae) and of the GTV (soft‐tissue) with an expansion of 5 mm was chosen in order to create a 3D shape of the region of interest (ROI). That ROI was automatically registered to each phase of the 4D CBCT. The goal was to verify that the overall tumor motion excursion measured on the ten phases was within the PTV margins applied on the Mid‐V phase. In case a shift was detected, only the translation corrections relative to the GTV isocenter were applied to the couch, because rotation corrections were not supported by our treatment couch. A second 4D CBCT was acquired after couch correction to assess the residual setup errors. Again, a dual automatic registration of both bony anatomy and ROI was performed in order to visually validate the target alignment. A posttreatment 4D CBCT scan was acquired at the end of the treatment delivery to quantify the intra‐fraction motion errors, obtained as the difference in target alignment between the second and the third 4D CBCT scan. To reduce the additional dose to the patient, the first 4D CBCT was acquired with the standard protocol of 4 minutes, while the second 4D CBCT was reduced to 2 minutes by downsizing the number of projections and the final 4D‐CBCT to only 1 minute. The resulting image quality was good enough to evaluate the intra‐fraction motion errors. 18 Finally, the 3D couch shifts from the three 4D CBCTs using soft‐tissue and bony registration were collected for all treatment fractions and for all patients and used to retrospectively determine the margins according to our data as described in the Margins section.
2.5. Margins
The 3D couch shifts using soft‐tissue and bony registration were collected for all treatment fractions for all patients. The mean and standard deviation were calculated for each patient. From these data, the standard deviation of the systematic error (∑), and standard deviation of the random error (σ) were calculated. The ∑ was obtained by calculating the standard deviation of the mean for each patient, and the σ was the root mean square of the standard deviations for each patient. To analyze the difference between the bony and soft‐tissue registration, the couch shifts obtained using soft‐tissue registration were subtracted from the couch shifts obtained using bony registration in each direction. Finally, the PTV margins, M(PTV), for frameless SBRT patients with online 4D CBCT image guidance were calculated for each patient by applying the van Herk equation 10 :
| (1) |
where ∑TOT and σTOT are the overall systematic and random errors (as defined in Equations 2 and 3) 19 and σp is the width of the penumbra modeled by a cumulative Gaussian.
| (2) |
Sum of the standard deviations of the systematic errors calculated from delineation, localization and intra‐fraction.
| (3) |
Sum of the root mean square of the random errors calculated from localization, intra‐fraction and respiratory motion.
For the lung, σp was taken equal to 0.64 cm as analytically estimated by Mexner et al. 20 Equation 1 describes the GTV to PTV margin necessary to ensure that the GTV receives 99 % of the prescribed dose for 90 % of the patients when all geometric uncertainties are included. The target delineation error (1 SD = 2 mm for T1‐T2 tumor staging), 21 , 22 the target localization error and the intra‐fraction motion error were considered as systematic errors. The latter comes from the fact that the treatment lasts longer than the planning CT and therefore the free breathing of the patient causes a deviation in the shape of the total dose distribution. For each patient the respiratory motion error is calculated according to the Lujan equation. 23 The margins used for the patients treatment were initially taken from the data of systematic and random errors reported in the literature 17 (target localization accuracy, intra‐fraction motion and target delineation uncertainty, intra‐fraction motion and respiratory motion, see Table 2). Then the errors obtained from the retrospective analysis of the patients treated at our institution were used to compute customized margins.
Table 2.
Systematic and random errors of van Herk equation for margins calculation based on the off‐line analysis (4D CBCT data) and from literature (treatment); the latter was taken as reference. A is the target motion amplitude.
| LR (cm) | AP (cm) | SI (cm) | |
|---|---|---|---|
| Systematic errors ∑e | |||
| Localisation | |||
| Off‐line | 0.09 | 0.15 | 0.12 |
| Treatment | 0.08 | 0.09 | 0.08 |
| Delineation | |||
| Off‐line | 0.2 | 0.2 | 0.2 |
| Treatment | 0.2 | 0.2 | 0.2 |
| Intra‐fx | |||
| Off‐line | 0.03 | 0.07 | 0.12 |
| Treatment | 0.12 | 0.18 | 0.12 |
| Random errors σe | |||
| Localisation | |||
| Off‐line | 0.14 | 0.15 | 0.2 |
| Treatment | 0.11 | 0.14 | 0.11 |
| Target motion | |||
| Off‐line | 0.36xA(LR) | 0.36xA(AP) | 0.36xA(SI) |
| Treatment | 0.36xA(LR) | 0.36xA(AP) | 0.36xA(SI) |
| Intra‐fx | |||
| Off‐line | 0.14 | 0.15 | 0.22 |
| Treatment | 0.13 | 0.18 | 0.15 |
2.6. Iterative analysis
To assess the robustness of our data, the margins were recalculated with an iterative method for different subsets of 10, 15, 20, 25 and 30 patients taken in chronological order (p + 1) with respect to their treatment. The scope was to determine whether or not the margins calculated were converging for samples with increasing number of patients. This approach has been chosen at first due to its rather simple implementation; however it presents a major drawback, the lack of large data to build good statistics. This was a clear limitation to validate our results.
2.7. Bootstrap analysis
The principle of the bootstrap method is that inference regarding a population can be modeled by resampling with replacement a subset of this population. 24 , 25 In this way, it is possible to expand the sampling from a limited pool of data and better estimate the statistical parameters of the population. In particular, for each patient error (target localisation accuracy, intra‐fraction motion, and target delineation), a resampling was computed with different cohort sizes to create new systematic and random errors. For the bootstrap calculation the delineation systematic error was fixed at 2 mm for all patients. The localization systematic error was defined as: Σloc = SD (M(p)) where SD represents the standard deviation, M represents the mean, and p represents the pth patient. The pth is a patient created from a resampling with replacement of the localization patient’s data of one patient randomly chosen. The intra‐fraction systematic error was defined as Σintra = SD (M(s)) where s represents the sth session. The sth is a session created from a resampling with replacement of the intra‐fraction patient’s data of n patients randomly chosen.
The motion amplitude random error was fixed at 0.36 x patient’s motion amplitude (A). The localization random error was defined as where n represents the number of patient and p represents the pth patient. Finally, the intra‐fraction random error was defined as: where n represents the number of patient and s represents the sth session.
In our experiment, the cohort size was defined by the number of patients n included in this cohort with n equal to 3,6,9,12,15,30,50,75,100 and 150. For each sampling, bootstrap calculation was repeated 1000 times with random choice of patients at each time. The mean and standard error was calculated from the results obtained with these 1000 repetitions.
3. RESULTS
3.1. Target motion
Figure 1 shows the relation of the target motion between 4D CT and the first 4D CBCT in the three directions. The correlation coefficient was R2 = 0.96 in the LR and SI directions, and R2 = 0.92 in the AP direction.
Fig. 1.

Correlation between 4D CT and 4D CBCT target motion displacement in all directions. The dashed‐dotted line corresponds to a unity fit.
3.2. Error analysis
Figure 2 shows the histograms obtained from the analysis of the target baseline shift, the target localisation, and the intra‐fraction motion errors on the 229 fractions, in the three directions. The mean and standard deviation of the target baseline shift were 0.00 ± 0.16 cm, 0.02 ± 0.25 cm and 0.01 ± 0.22 cm for LR, AP, and SI directions, respectively. The mean and standard deviation of the target localization were −0.01 ± 0.16 cm, −0.11 ± 0.21 cm and 0.06 ± 0.21 cm for LR, AP and SI directions, respectively. The mean and standard deviation of the intra‐fraction were −0.00 ± 0.17 cm, −0.02 ± 0.18 cm, and 0.01 ± 0.15 cm for LR, AP and SI directions, respectively.
Fig. 2.

Histograms of the target baseline‐shift (left), target localization accuracy (centre), and intra‐fraction motion (right), in the three directions. The solid curves represent a gaussian fit of the data.
3.3. Margins computation
As expected, 26 , 27 the systematic errors are dominated by the delineation error (Table 2). All errors used for treatments (data from literature) were in general smaller than the ones calculated retrospectively (off‐line analysis) with the exceptions of the intra‐fraction in the LR and AP directions for the systematic error and AP direction for the random error (Table 2).
Figure 3 shows the PTV margins based on published data and off‐line data from 30 patients treated at our center. The margins calculated with off‐line data were systematically larger than those coming from the literature.
Fig. 3.

PTV margins calculated according to the off‐line analysis (4D CBCT data; filled marker) and from treatment (literature data; empty marker), in the three directions and for the 30 patients, respectively. Abbreviations: LR, Left‐Right; AP, Anterior ‐Posterior; SI, Superior‐Inferior.
3.4. Iterative analysis
The margins calculated with the iterative analysis using different subsets of patient samples are reported in Figure 4, along with their corresponding standard error. An asymptotic margin reduction trend is observed as the number of patients involved in the calculation increases.
Fig. 4.

Margins calculated from the off‐line analysis (4D CBCT data) for a different number of patients. The error standard bars for each data are also shown in the graph. Abbreviations: LR, Left‐Right; AP, Anterior ‐Posterior; SI, Superior‐Inferior.
3.5. Bootstrap
Figure 5 shows the results of the margins calculated applying the bootstrap method for different simulations (number of included patients being 3, 6, 9, 12, 15, 30, 50, 75, 100 and 150), along with their standard errors. We did not observe any statistical difference on the calculated margins for cohort sizes including more than 15 patients.
Fig. 5.

PTV margins calculated from the bootstrap analysis on the 4D CBCT data, in the three directions and for the 3 to 150 bootstrap simulations according to different initial patient sample sizes, 10, 15, 20 and 28, taken consecutively. The standard error bars for each data are also shown in the graph. Abbreviations: LR, Left‐Right; AP, Anterior ‐Posterior; SI, Superior‐Inferior.
4. DISCUSSION
The aim of our study was to provide centers, which are either implementing frameless lung SBRT or still using literature margins, a method to calculate personalized margins. The method proposed in this paper takes into account changes in the process due to modification of contentions, treatment technique, etc. In those cases, it is crucial to verify the applied margins to ensure continued safe SBRT delivery. We therefore retrospectively analyzed our patient cohort to assess the margin uncertainties induced by respiratory motion during frameless stereotactic radiotherapy, and then compared them with already published data. We also determined the minimum number of patients required to validate our treatment margins based initially on literature data with an iterative method and a bootstrap method. The bootstrap method performed better than the iterative method. The former having larger data than the latter was capable to provide better statistics and so to better converge.
At first, we assessed the target motion excursion for each patient by analysing 4D CT data. As expected, we found that the most important motion was in the superior‐inferior direction, with a maximum tumor motion of 2.2 cm, in agreement with other authors. 13 , 14 The tumors located in the lower lobe were the most impacted by the large motion amplitude, while the upper and median lobes were giving similar results. In this specifc case, the reliability of the frameless approach with respect to the breathing managing technique might be questionable. However, in our cohort we found only one patient where the motion amplitude was superior to 2 cm that would have justified the benefit of using breathing management technique. Moreover, we found a correlation between motion excursion detected in the 4D CT and in the 4D CBCT data, with a correlation coefficient of R2 = 0.96 in the LR and SI directions, and R2 = 0.92 in the AP direction. The observed differences may be due to the different techniques used for phase sorting, i.e belt for 4D CT and diaphragm motion for 4D CBCT. Nevertheless, the respiratory motion assessed from the 4D CT scan was mostly reproducible during the treatment delivery for our patient cohort (see Figure 1). 28 , 29 , 30 , 31 As also found in a recent paper of Liang, et al, 32 if the baseline shift can be corrected by treatment couch, the target motion range is comparable to the one assessed with the 4DCT. Regarding the use of the 4D CBCT, it should be noted that for an ITV approach, the 3D CBCT alone may be sufficient since the blurred target volume on the 3D CBCT can be associated to an ITV; however for a Mid‐V approach, a 4D CBCT is highly recommended as confirmed by others. 33 , 34 , 35 From the retrospective 4D CBCT data analysis, we observed that the target delineation was the largest error as was found by others. 26 , 27 It is well‐known, 10 that this systematic error has a big impact on the margin definition. Unfortunately, this error was not assessed in this study as well as the sigma penumbra and we consider those two as limitations of the study. From the analysis of the target baseline shift, the target localization, and the target intra‐fraction motion we found, in all directions, mean values of maximum 0.2 mm and standard deviations of maximum 2.5 mm. This indicates the robustness of the Mid‐V strategy associated with the van Herk equation (see Figure 2). The larger systematic errors found for the AP target localization are probably caused by the patient relaxing between the first and second 4D CBCT. The values obtained for the systematic and random localization errors, i.e., discrepancies between planned and actual tumor position after corrections have been applied, were comparable to what was found by Sonke et al. 17 However, the applicability of the van Herk equation in the context of SBRT might be still questioned. Within this context, Ecclestone et al 36 have recently investigated the robustness of the van Herk equation to variation in tumor size, motion amplitude, tissue density and plan technique in lung radiotherapy and they ensured the safe clinical application of the van Herk margins as no CTV under dosage was observed. Another aspect to consider in the van Herk equation is the difference of the number of fractions for SBRT over standard radiotherapy treatment. For this reason as reported by Leong et al. 37 and van Herk et al, 38 in Equation 1 an additional systematic error was taken into account, being the quadratic sum of the random errors divided by the square root of the number of fractions. Moreover, Sonke et al. 17 suggested that if the errors are quantified from a limited number of fractions, this effect will be implicitly taken into account when calculating margins. Therefore, the above considerations justify the application of the van Herk equation to the Mid‐V approach for safe lung SBRT. In particular, the Mid‐V approach minimizes some of those systematic errors, such as target localization and baseline shifts errors, hence reducing the margins size for a better sparing of the organs at risk. It should be noted that mid‐position, a refinement of the Mid‐V concept, would have even more improved the image quality by means of artifacts reduction as described by Wolthaus et al, 39 thus providing a better representation of the tumor shape and volume. However, this approach is more complex and time consuming since it requires a reliable deformable image registration tool. Nevertheless, Peulen et al 40 have reported an excellent local control of 98% using the Mid‐V based PTV margin approach combined with online image guided SBRT in early stage lung cancer.
Senthi et al 41 have reported in their sytematic review low level of toxicity with SBRT, offering a safe and effective curative treatment for patients with central tumors who unfit for surgery. In Figure 3 was shown the comparison between the applied systematic and random errors obtained from the literature (treatment) and the systematic and random errors calculated retrospectively from the 4D CBCT (off‐line analysis). The comparison illustrated that the treatment margins were systematically larger in all directions with the largest difference of about 1 mm in the SI direction. Our results seem to indicate that margins calculation depends on the local parameters of the patient cohort, treatment technique and immobilization system as described by Lin et al 42 and that the parameters used in the literature may not be used locally without caution. In other terms, data from the literature might be taken as a starting point, but the margins applied to patients should be re‐evaluated with local results obtained through acquired experience (i.e. patient treatments). Not performing that local evaluation could lead to overly large margins that might, in certain cases, be clinically unacceptable for lung stereotactic treatments. For this reason, to assess the robustness of our results and to determine the minimum number of patients required to validate custom margins, the latters were calculated using first an iterative method. As shown in Figure 4, the results did not converge for 30 patients; in particular, a monotone decreasing function with associated large errors bars was observed. As a consequence, the bootstrap method was chosen, providing more statistics. This method was recently implemented in radiation oncology to estimate toxicity, setup errors, organ motion, or in other applications. 43 , 44 , but it was never applied to the context of margin validation. The analysis showed that, independently from the initial patient sample size, a sample of at least 15 patients was needed to observe a convergence (see Figure 5). This is in agreement with a similar study conducted by Matsumoto et al, 45 Chaikh et al, 46 where they also reported that the bootstrap method can be considered as a practical solution to simulate a larger population in case of a small sample size. In their paper, the authors recommended the use of the bootstrap for a sample size larger than 10 to provide good estimation in case of heterogeneous and not normally distributed data. The main difference between the iterative and bootstrap methods is that with the iterative method we can only extrapolate the data to obtain the correct margins, while it is possible with the bootstrap method to reach a convergence (plateau in Figure 5) with at least 10 patients, 28 and so to define the correct margins in each direction.
A limitation of this study is that rotational errors were not taken into account in the margins computation, because our linear accelerator was not equipped with a 6 degrees of freedom (DOF) couch. However, in our study we did not observe rotation angles larger than 1°. Besides, it is important to notice that the lung SBRT tumors are generally small and spherical in shape; thereby the value of rotational shifts is further minimized, by placing the isocenter within the GTV. Indeed, as found by Ottoson et al, 47 CTV to PTV margins were approximately the same, regardless if the CBCT matches were performed with 3 or 6 DOF. Finally a robotic couch wouldn’t lead to further margin reduction.
If we now consider the impact of the type of technique VMAT or IMRT to the margins, in the publication of Rana et al 48 it has been shown that the major advantage of VMAT over IMRT is in the reduction of the number of monitor units leading to a faster treatment delivery times without compromising the quality of the treatment plans. Hence, faster delivery time is more patient‐friendly and minimizes intra‐fraction patient motion enabling the reduction of the treatment margins. 49 , 50 In line with this study, in our center all SBRT are delivered with VMAT technique.
5. CONCLUSIONS
The study presented here is a retrospective margins analyisis collected on a group of patients. We believe that this analysis could be beneficial to centers that want to apply personalized margins or simply adapt their margins.
The minimum number of patients needed to reach a convergence in the margin definition was evaluated using both iterative and bootstrap methods. The two methods provided similar results within the uncertainties. However, the iterative method was not converging because the number of patients of our cohort was not enough to reach conclusions on the margins. On the contrary, the bootstrap method showed that the required patient sample size to validate our treatment margins for frameless lung SBRT on a population scale was 15 patients.
To conclude, when implementing lung SBRT treatments, or when adapting the lung SBRT treatment protocol due to changes in local practice, an analysis based on the bootstrap method is suggested to verify the safe delivery of the treatment, without adding extra dose to the patient and increasing the treatment time.
REFERENCES
- 1. Keall PJ, Mageras GS, Balter JM, et al. The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med Phys. 2006;33:3874‐3900. [DOI] [PubMed] [Google Scholar]
- 2. Pan T, Lee TY, Rietzel E, Chen GT. 4D‐CT imaging of a volume influenced by respiratory motion on multi‐slice CT. Med Phys. 2004;31:333‐340. [DOI] [PubMed] [Google Scholar]
- 3. Keall PJ, Starkschall G, Shukla H, et al. Acquiring 4D thoracic CT scans using a multislice helical method. Phys Med Biol. 2004;49:2053‐2067. [DOI] [PubMed] [Google Scholar]
- 4. Handels H, Werner R, Frenzel T, et al. Generation of 4D CT image data and analysis of lung tumour mobility during the breathing cycle. Stud Health Technol Inform. 2006;124:977‐982. [PubMed] [Google Scholar]
- 5. Guckenberger M, Wilbert J, Meyer J, Baier K, Richter A, Flentje M. Is a single respiratory correlated 4D‐CT study sufficient for evaluation of breathing motion? Int J Radiat Oncol Biol Phys. 2007;67:1352‐1359. [DOI] [PubMed] [Google Scholar]
- 6. Yamamoto T, Kabus S, Lorenz C, et al. 4D CT lung ventilation images are affected by the 4D CT sorting method. Med Phys. 2013;40:101907. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7. Zhang SX, Zhou LH, Lin SQ, et al. 4D‐CT reconstruction based on pulmonary average CT values. Bio‐Med Mater Eng. 2014;24:85‐94. [DOI] [PubMed] [Google Scholar]
- 8. Wolthaus JW, Sonke JJ, van Herk M, et al. Comparison of different strategies to use four‐dimensional computed tomography in treatment planning for lung cancer patients. Int J Radiat Oncol Biol Phys. 2008;70:1229‐1238. [DOI] [PubMed] [Google Scholar]
- 9. Wolthaus JW, Schneider C, Sonke JJ, et al. Mid‐ventilation CT scan construction from four‐dimensional respiration‐correlated CT scans for radiotherapy planning of lung cancer patients. Int J Radiat Oncol Biol Phys. 2006;65:1560‐1571. [DOI] [PubMed] [Google Scholar]
- 10. van Herk M, Remeijer P, Rasch C, Lebesque JV. The probability of correct target dosage: dose‐population histograms for deriving treatment margins in radiotherapy. Int J Radiat Oncol Biol Phys. 2000;47:1121‐1135. [DOI] [PubMed] [Google Scholar]
- 11. Sonke JJ, Zijp L, Remeijer P, van Herk M. Respiratory correlated cone beam CT. Med Phys. 2005;32:1176‐1186. [DOI] [PubMed] [Google Scholar]
- 12. Nakagawa K, Haga A, Kida S, et al. 4D registration and 4D verification of lung tumor position for stereotactic volumetric modulated arc therapy using respiratory‐correlated cone‐beam CT. J Radiat Res. 2013;54:152‐156. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13. Seppenwoolde Y, Shirato H, Kitamura K, et al. Precise and real‐time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. Int J Radiat Oncol Biol Phys. 2002;53:822‐834. [DOI] [PubMed] [Google Scholar]
- 14. Sonke JJ, Lebesque J, van Herk M. Variability of four‐dimensional computed tomography patient models. Int J Radiat Oncol Biol Phys. 2008;70:590‐598. [DOI] [PubMed] [Google Scholar]
- 15. Benedict SH, Yenice KM, Followill D, et al. Stereotactic body radiation therapy: The report of AAPM Task Group 101. Med Phys. 2010;37(8):4078‐4101. [DOI] [PubMed] [Google Scholar]
- 16. Ford EC, Mageras GS, Yorke E, Ling CC. Respiration‐correlated spiral CT: a method of measuring respiratory‐induced anatomic motion for radiation treatment planning. Med Phys. 2003;30:88‐97. [DOI] [PubMed] [Google Scholar]
- 17. Sonke JJ, Rossi M, Wolthaus J, van Herk M, Damen E, Belderbos J. Frameless stereotactic body radiotherapy for lung cancer using four‐dimensional cone beam CT guidance. Int J Radiat Oncol Biol Phys. 2009;74:567‐574. [DOI] [PubMed] [Google Scholar]
- 18. Westberg J, Jensen HR, Bertelsen A, Brink C. Reduction of Cone‐Beam CT scan time without compromising the accuracy of the image registration in IGRT. Acta Oncol. 2010;49(2):225‐229. [DOI] [PubMed] [Google Scholar]
- 19. van Herk M. Errors and margins in radiotherapy. Semin Radiat Oncol. 2004;14(1):52‐64. [DOI] [PubMed] [Google Scholar]
- 20. Mexner V, Wolthaus JCH, van Herk M, Damen EMF, Sonke JJ. Effects of respiration‐induced density variations on dose distributions in radiotherapy of lung cancer. Int J Radiat Oncol Biol Phys. 2009;74(4):1266‐1275. [DOI] [PubMed] [Google Scholar]
- 21. Steenbakkers RJ, Duppen JC, Fitton I, et al. Observer variation in target volume delineation of lung cancer related to radiation oncologist‐computer interaction: a 'Big Brother' evaluation. Radiother Oncol. 2005;77:182‐190. [DOI] [PubMed] [Google Scholar]
- 22. Thengumpallil S, Germond JF, Bourhis J, Bochud F, Moeckli R. Impact of respiratory‐correlated CT sorting algorithms on the choice of margin definition for free‐breathing lung radiotherapy treatments. Radiother Oncol. 2016;119(3):438‐443. [DOI] [PubMed] [Google Scholar]
- 23. Lujan AE, Larsen EW, Balter JM, Ten Haken RK. A method for incorporating organ motion due to breathing into 3D dose calculations. Med Phys. 1999;26:715‐720. [DOI] [PubMed] [Google Scholar]
- 24. Efron B, Tibshirani R. An introduction to the bootstrap. New York: Chapman & Hall; 1994. [Google Scholar]
- 25. Gallas BD, Gallas BD. Variance of the channelized‐hotelling observer from a finite number of trainers and testers, Proc. SPIE 5034, Medical Imaging 2003: Image Perception, Observer Performance, and Technology Assessment. 2003; 10.1117/12.480334. [DOI]
- 26. Lin R. Target volume delineation and margins in the management of lung cancers in the era of image guided radiation therapy. J Med Radiat Sci. 2014;61(1):1‐3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27. Vinod SK, Jameson MG, Min M, Holloway LC. Uncertainties in volume delineation in radiation oncology: A systematic review and recommendations for future studies. Radiother Oncol. 2016;121(2):169‐179. [DOI] [PubMed] [Google Scholar]
- 28. Gottlieb KL, Hansen CR, Hansen O, Westberg J, Brink C. Investigation of respiration induced intra‐ and inter‐fractional tumour motion using a standard Cone Beam CT. Acta Oncol. 2010;49(7):1192‐1198. [DOI] [PubMed] [Google Scholar]
- 29. Liu G, Hu F, Ding X, et al. Simulation of dosimetry impact of 4DCT uncertainty in 4D dose calculation for lung SBRT. Radiation Oncology. 2019;14(1). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30. Li X, Yang Y, Li T, Fallon K, Heron ED, Huq MS. Dosimetric effect of respiratory motion on volumetric‐modulated arc therapy‐based lung SBRT treatment delivered by TrueBeam machine with flattening filter‐free beam. J Appl Clin Med Phys. 2013;14(6):195‐204. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31. Cuijpers JP, Verbakel WFAR, Slotman BJ, Senan S. A novel simple approach for incorporation of respiratory motion in stereotactic treatments of lung tumors. Radiother Oncol. 2010;97(3):443‐448. [DOI] [PubMed] [Google Scholar]
- 32. Liang Z, Yang J, Liu H, et al. Real‐time tumor motion monitoring and PTV margin determination in lung SBRT treatment. Acta Oncol. 2019;1‐4. [DOI] [PubMed] [Google Scholar]
- 33. Sweeney RA, Seubert B, Stark S, et al. Accuracy and inter‐observer variability of 3D versus 4D cone‐beam CT based image‐guidance in SBRT for lung tumors. Radiation Oncology. 2012;7(1):81. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34. Thengumpallil S, Smith K, Monnin P, Bourhis J, Bochud F, Moeckli R. Difference in performance between 3D and 4D CBCT for lung imaging: a dose and image quality analysis. J Appl Clin Med Phys. 2016;17(6):97‐106. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35. Tan Z, Liu C, Zhou Y, Shen W. Preliminary comparison of the registration effect of 4D‐CBCT and 3D‐CBCT in image‐guided radiotherapy of Stage IA non–small‐cell lung cancer. J Rad Res. 2017;58(6):854‐861. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36. Ecclestone G, Bissonnette J‐P, Heath E. Experimental validation of the van Herk margin formula for lung radiation therapy. Med Phys. 2013;40(11):111721. [DOI] [PubMed] [Google Scholar]
- 37. Leong J. Implementation of random positioning error in computerised radiation treatment planning systems as a result of fractionation. Phys Med Biol. 1987;32:327‐334. [DOI] [PubMed] [Google Scholar]
- 38. Van Herk M, Witte M, van der Geer J, Schneider C, Lebesque JV. Biologic and physical fractionation effects of random geometric errors. Int J Rad Oncol Biol Phys. 2003;57(5):1460‐1471. [DOI] [PubMed] [Google Scholar]
- 39. Wolthaus JW, Sonke JJ, van Herk M, Damen EM. Reconstruction of a time‐averaged midposition CT scan for radiotherapy planning of lung cancer patients using deformable registration. Med Phys. 2008;35:3998‐4011. [DOI] [PubMed] [Google Scholar]
- 40. Peulen H, Belderbos J, Rossi M, Sonke J‐J. Mid‐ventilation based PTV margins in Stereotactic Body Radiotherapy (SBRT): A clinical evaluation. Radiother Oncol. 2014;110(3):511‐516. [DOI] [PubMed] [Google Scholar]
- 41. Senthi S, Haasbeek CJA, Slotman BJ, Senan S. Outcomes of stereotactic ablative radiotherapy for central lung tumours: A systematic review. Radiother Oncol. 2013;106(3):276‐282. [DOI] [PubMed] [Google Scholar]
- 42. Lin C, Xu S, Yao W, Wu Y, Fang J, Wu V. Comparison of set up accuracy among three common immobilisation systems for intensity modulated radiotherapy of nasopharyngeal carcinoma patients. J Med Radiat Sci. 2017;64(2):106‐113. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43. Palombarini M, Mengoli S, Fantazzini P, Cadioli C, Degli Esposti C, Frezza GP. Analysis of inter‐fraction setup errors and organ motion by daily kilovoltage cone beam computed tomography in intensity modulated radiotherapy of prostate cancer. Radiation Oncology. 2012;7(1):56. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44. Hout W, Kramer G, Noordijk E, et al. Cost‐ utility analysis of short‐versus long‐course palliative radiotherapy in patients with Non – Small‐Cell Lung Cancer. J Natl Cancer Inst. 2006;98(24):1786‐1794. [DOI] [PubMed] [Google Scholar]
- 45. Matsumoto M, Ohta S, Ohno Y, Ogata Y. Study of setup margins in radiation therapy: how many verification times and patients are required. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2010;66:1186‐1196.20975239 [Google Scholar]
- 46. Chaickh A, Bresciani JP, Balosso J. The Bootstrap method to improve statistically analysis of dosimetric data for radiotherapy outcomes. Int J Cancer Therap Oncol. 2017;1:5. [Google Scholar]
- 47. Ottosson W, Baker M, Hedman M, Behrens CF, Sjöström D. Evaluation of setup accuracy for NSCLC patients; studying the impact of different types of cone‐beam CT matches based on whole thorax, columna vertebralis, and GTV. Acta Oncol. 2010;49(7):1184‐1191. [DOI] [PubMed] [Google Scholar]
- 48. Rana SB. Volumetric intensity modulated arc therapy in lung cancer. Current Literature Rev. 2013;2:9‐13. [Google Scholar]
- 49. Rossi MMG, Peulen HMU, Belderbos JSA, Sonke J‐J. Intrafraction motion in stereotactic body radiation therapy for non‐small cell lung cancer: intensity modulated radiation therapy versus volumetric modulated arc therapy. Int J Rad Oncol Biol Phys. 2016;95(2):835‐843. [DOI] [PubMed] [Google Scholar]
- 50. Vloet A, Li W, Giuliani M, et al. Comparison of residual geometric errors obtained for lung SBRT under static beams and VMAT techniques: Implications for PTV margins. Physica Med. 2018;52:129‐132. [DOI] [PubMed] [Google Scholar]