Abstract
Tissue paper is defined by its physical and mechanical properties, namely: high softness, low grammage, high bulk and high liquid absorption capacity. It is expected that the production of tissue paper will continue to grow, which increases the importance of better understanding the processes involved in its production as well as its optimization [1]. The experimental data presented in this article, are the physical-mechanical characterization of a group of 13 industrial base tissue papers, which were collected at the end of the tissue paper machine on Portuguese factories. These samples vary in grammage, composition and creping [2], enabling a later evaluation of the crepe type [3] and its relationship with the final properties of the tissue paper.
Keywords: Industrial base tissue paper, Fiber morphology, Structural properties, Mechanical characterization, Absorption capacity, Tissue softness
Specifications Table
Subject | Materials Science (General) |
Specific subject area | Industrial Base Tissue Paper |
Type of data | Tables |
How data were acquired | MorFi® analyzer (morphological analysis), ISO standards methods, AccuPyc® II 1340 helium pycnometer (porosity analysis), TSA - Tissue Softness Analyzer (softness analysis) |
Data format | Raw and Analyzed data |
Parameters for data collection | 13 industrial base tissue papers with different grammages were obtained in situ on Portuguese factories |
Description of data collection | Techpap MorFi® analysis was performed to determine the industrial base paper morphology. Papers grammage, thickness and bulk were measured using paper tissue standards ISO 12625-6 and ISO 12625-3 respectively. The porosity was determined using a Micromeritics AccuPyc® II 1340 helium pycnometer. The absorption capacity was measured according to ISO 12625-8 applying the immersion method. Tensile tests were done in machine and cross directions (MD and CD) according with ISO 12625-4. Handfeel, real softness, smoothness/roughness, and stiffness were measured using the Emtec TSA - Tissue Softness Analyzer. All these determinations were done at 23°C and 50% humidity (ISO 187). |
Data source location | FibEnTech - Fiber Materials and Environmental Technologies Research Unit, Universidade da Beira Interior (UBI), Covilhã, Portugal RAIZ - Forest and Paper Research Institute, Eixo, Aveiro, Portugal |
Data accessibility | With the article |
Value of the Data
-
•
The data are relevant in tissue paper materials research to obtain premium tissue paper materials.
-
•
These data allow to evaluate the relationship between the final properties of the paper and the raw material.
-
•
These data allow to evaluate the relationship between the raw material and the type of crepe obtained with a specific creping angle and blade.
-
•
These data could make an important impact in the industrial production of tissue paper.
1. Data Description
In this article are presented the mean values and the standard deviations for all the measured data for the characterization of 13 industrial base tissue papers (identified from A to M) of different Portuguese factories. In Table 1 is showed the data of grammage, thickness and bulk for all the industrial base tissue papers. The morphological data for all the industrial base tissue papers, which is available in Tables 2 and 3, correspond to the number of fibers, length, width, coarseness, kink, curl, broken ends, and fines. Table 4 presents the results of the measured data in the porosity tests for all the industrial base tissue papers and the calculated apparent porosity [4]. The obtained data for water absorption time and water absorption capacity are shown in Table 5. In Tables 6 and 7 are listed the mechanical properties measured (tensile tests) in the machine direction (MD) and cross direction (CD) for all the industrial base tissue papers. The properties are the force, strength, tensile index, elongation at break, and Young modulus. Finally, the handfeel tests results (HF) and the corresponding TSA parameters, in particular, real softness/ fiber stiffness (TS7), paper surface roughness (TS750), frequency (fTS750), paper stiffness (D), plasticity (P), hysteresis (H), and elasticity (E) for all the industrial base tissue papers on top (Yankee side), bottom (Hood side), and globally are found in Tables 8,9,10,11 and 12. All the raw data presented in this manuscript is available in the Excel file attached as an appendix supplementary material.
Table 1.
Mean values and standard deviations of the grammage, thickness and bulk tests data for all the industrial base tissue papers.
Grammage (g/m2) |
Thickness (µm) |
Bulk (cm3/g) |
||||
---|---|---|---|---|---|---|
Base paper | ±σ | ±σ | ±σ | |||
A | 19.1 | 0.1 | 121.0 | 2.1 | 6.33 | 0.10 |
B | 18.8 | 0.2 | 137.8 | 4.4 | 7.32 | 0.26 |
C | 16.2 | 0.2 | 122.9 | 1.5 | 7.58 | 0.10 |
D | 17.2 | 0.1 | 113.0 | 1.2 | 6.55 | 0.07 |
E | 15.8 | 0.1 | 113.3 | 0.9 | 7.16 | 0.06 |
F | 16.3 | 0.2 | 126.2 | 1.9 | 7.74 | 0.10 |
G | 15.7 | 0.3 | 116.2 | 2.7 | 7.41 | 0.25 |
H | 15.8 | 0.2 | 116.3 | 2.7 | 7.37 | 0.24 |
I | 15.7 | 0.3 | 110.0 | 2.4 | 7.03 | 0.22 |
J | 16.0 | 0.3 | 112.5 | 0.7 | 7.09 | 0.14 |
K | 16.0 | 0.4 | 110.7 | 1.9 | 6.89 | 0.26 |
L | 17.5 | 0.2 | 126.7 | 1.3 | 7.25 | 0.09 |
M | 17.3 | 0.2 | 131.4 | 2.3 | 7.62 | 0.11 |
Table 2.
Mean values and standard deviations of the morphology test data for all the industrial base tissue papers.
Fibers (million/g) |
Length weighted in length (mm) |
Width (µm) |
Coarseness (mg/100 m) |
|||||
---|---|---|---|---|---|---|---|---|
Base paper | ±σ | ±σ | ±σ | ±σ | ||||
A | 18.0 | 1.1 | 0.850 | 0.007 | 19.5 | 0.1 | 8.04 | 0.00 |
B | 14.7 | 0.2 | 0.930 | 0.004 | 20.8 | 0.2 | 9.47 | 0.00 |
C | 16.7 | 0.2 | 0.860 | 0.006 | 20.1 | 0.1 | 8.80 | 0.00 |
D | 14.7 | 0.2 | 0.930 | 0.004 | 20.8 | 0.2 | 9.47 | 0.00 |
E | 16.8 | 0.4 | 0.862 | 0.010 | 20.0 | 0.1 | 8.73 | 0.26 |
F | 17.4 | 0.2 | 0.859 | 0.002 | 20.3 | 0.3 | 8.48 | 0.12 |
G | 18.1 | 0.5 | 0.814 | 0.006 | 19.4 | 0.1 | 8.32 | 0.25 |
H | 18.3 | 0.5 | 0.812 | 0.005 | 19.4 | 0.1 | 8.22 | 0.21 |
I | 21.2 | 0.3 | 0.733 | 0.005 | 19.6 | 0.1 | 7.87 | 0.09 |
J | 20.4 | 0.3 | 0.742 | 0.002 | 19.6 | 0.1 | 8.11 | 0.11 |
K | 20.8 | 0.1 | 0.732 | 0.001 | 19.8 | 0.1 | 8.04 | 0.06 |
L | 22.4 | 0.1 | 0.740 | 0.001 | 19.3 | 0.0 | 7.14 | 0.03 |
M | 17.3 | 0.2 | 0.784 | 0.003 | 20.7 | 0.1 | 9.25 | 0.06 |
Table 3.
Mean values and standard deviations of the morphology test data for all the industrial base tissue papers.
Kink fibers (%) |
Curl (%) |
Broken ends (%) |
Fines (% area) |
|||||
---|---|---|---|---|---|---|---|---|
Base paper | ±σ | ±σ | ±σ | ±σ | ||||
A | 40.1 | 0.2 | 9.2 | 0.0 | 23.2 | 0.3 | 14.1 | 0.1 |
B | 43.7 | 0.2 | 10.0 | 0.0 | 26.8 | 0.3 | 14.3 | 0.3 |
C | 47.9 | 0.6 | 10.2 | 0.0 | 24.8 | 0.2 | 16.1 | 0.7 |
D | 43.7 | 0.2 | 10.0 | 0.0 | 26.8 | 0.3 | 14.3 | 0.3 |
E | 130.8 | 0.3 | 10.1 | 0.0 | 25.3 | 0.1 | 14.7 | 0.1 |
F | 130.7 | 0.2 | 10.4 | 0.0 | 26.3 | 0.9 | 16.1 | 0.9 |
G | 48.7 | 0.6 | 10.3 | 0.1 | 23.4 | 0.4 | 15.3 | 0.4 |
H | 48.0 | 0.6 | 10.2 | 0.0 | 22.7 | 0.4 | 14.5 | 0.5 |
I | 50.7 | 0.5 | 11.3 | 0.1 | 23.6 | 0.5 | 15.8 | 0.2 |
J | 50.7 | 0.2 | 11.2 | 0.1 | 24.0 | 0.5 | 16.0 | 0.3 |
K | 50.2 | 0.3 | 11.2 | 0.1 | 25.0 | 0.4 | 15.9 | 0.2 |
L | 45.6 | 0.2 | 9.8 | 0.1 | 22.6 | 0.1 | 13.9 | 0.1 |
M | 48.4 | 0.2 | 10.3 | 0.0 | 26.3 | 0.4 | 14.4 | 0.1 |
Table 4.
Mean values and standard deviations of the porosity tests data for all the industrial base tissue papers and the results of the apparent porosity.
Porosity (%) |
Apparent Porosity (%) | ||
---|---|---|---|
Base paper | ±σ | ||
A | 91.6 | 0.0 | 89.7 |
B | 90.9 | 0.0 | 91.1 |
C | 92.2 | 0.0 | 91.5 |
D | 90.8 | 0.0 | 90.6 |
E | 93.9 | 0.0 | 90.9 |
F | 89.1 | 0.0 | 91.7 |
G | 95.7 | 0.0 | 91.2 |
H | 95.7 | 0.0 | 91.1 |
I | 90.1 | 0.0 | 90.7 |
J | 90.9 | 0.0 | 90.8 |
K | 90.3 | 0.0 | 90.6 |
L | 90.8 | 0.0 | 91.1 |
M | 91.3 | 0.0 | 92.3 |
Table 5.
Mean values and standard deviations of the water absorption time and water absorption capacity tests data for all the industrial base tissue papers.
Water Absorption Time (s) |
Water Absorption Capacity (g/g) |
|||
---|---|---|---|---|
Base paper | ±σ | ±σ | ||
A | 4.688 | 0.420 | 6.862 | 0.310 |
B | 4.644 | 0.370 | 7.573 | 0.310 |
C | 3.969 | 0.030 | 8.173 | 0.090 |
D | 4.272 | 0.450 | 7.990 | 0.160 |
E | 4.895 | 0.510 | 7.636 | 0.170 |
F | 4.158 | 0.640 | 8.180 | 0.390 |
G | 4.852 | 0.060 | 9.007 | 0.190 |
H | 4.856 | 0.070 | 8.642 | 0.270 |
I | 4.606 | 0.060 | 7.850 | 0.130 |
J | 4.262 | 0.410 | 7.908 | 0.170 |
K | 4.727 | 0.510 | 7.883 | 0.210 |
L | 4.641 | 0.400 | 7.436 | 0.090 |
M | 4.852 | 0.510 | 8.614 | 0.250 |
Table 6.
Mean values and standard deviations of the tensile tests data (MD and CD) for all the industrial base tissue papers.
Force (N) |
Strength (N/m) |
Tensile Index (Nm/g) |
||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
MD |
CD |
MD |
CD |
MD |
CD |
|||||||
Base paper | ±σ | ±σ | ±σ | ±σ | ±σ | ±σ | ||||||
A | 14.19 | 1.00 | 8.80 | 0.30 | 0.284 | 0.020 | 0.176 | 0.006 | 14.86 | 1.04 | 9.21 | 0.32 |
B | 10.52 | 1.06 | 6.48 | 0.23 | 0.210 | 0.021 | 0.130 | 0.005 | 11.19 | 1.12 | 6.89 | 0.24 |
C | 8.71 | 0.45 | 4.40 | 0.23 | 0.175 | 0.009 | 0.088 | 0.005 | 10.62 | 0.55 | 5.37 | 0.28 |
D | 9.82 | 0.33 | 4.78 | 0.18 | 0.196 | 0.007 | 0.095 | 0.004 | 11.69 | 0.40 | 5.68 | 0.21 |
E | 8.60 | 0.60 | 4.37 | 0.29 | 0.172 | 0.012 | 0.087 | 0.006 | 10.68 | 0.74 | 5.43 | 0.36 |
F | 8.95 | 0.64 | 4.22 | 0.20 | 0.179 | 0.013 | 0.084 | 0.004 | 10.98 | 0.80 | 5.17 | 0.24 |
G | 7.96 | 0.72 | 3.94 | 0.13 | 0.159 | 0.014 | 0.079 | 0.003 | 10.14 | 0.92 | 5.02 | 0.16 |
H | 7.97 | 0.64 | 4.12 | 0.14 | 0.159 | 0.013 | 0.082 | 0.003 | 10.09 | 0.81 | 5.21 | 0.18 |
I | 7.75 | 0.46 | 4.08 | 0.09 | 0.156 | 0.010 | 0.082 | 0.002 | 9.87 | 0.59 | 5.20 | 0.11 |
J | 7.51 | 0.41 | 3.54 | 0.24 | 0.150 | 0.008 | 0.071 | 0.005 | 9.39 | 0.51 | 4.42 | 0.30 |
K | 8.19 | 0.31 | 3.80 | 0.26 | 0.164 | 0.006 | 0.076 | 0.005 | 10.24 | 0.39 | 4.75 | 0.32 |
L | 8.88 | 0.42 | 3.87 | 0.19 | 0.178 | 0.008 | 0.077 | 0.004 | 10.04 | 0.47 | 4.37 | 0.22 |
M | 8.38 | 0.34 | 3.68 | 0.15 | 0.168 | 0.007 | 0.074 | 0.003 | 10.03 | 0.41 | 4.40 | 0.17 |
Table 7.
Mean values and standard deviations of the tensile test data (MD and CD) for all the industrial base tissue papers.
Elongation at Break (%) |
Young Modulus (MPa) |
|||||||
---|---|---|---|---|---|---|---|---|
MD |
CD |
MD |
CD |
|||||
Base paper | ±σ | ±σ | ±σ | ±σ | ||||
A | 28.97 | 1.49 | 2.90 | 0.13 | 13.21 | 1.67 | 74.29 | 6.30 |
B | 24.16 | 1.53 | 3.02 | 0.15 | 8.36 | 0.97 | 42.22 | 2.42 |
C | 25.04 | 1.00 | 3.44 | 0.38 | 8.70 | 0.36 | 28.68 | 1.42 |
D | 22.53 | 1.78 | 4.00 | 0.47 | 15.04 | 2.36 | 31.53 | 2.19 |
E | 24.56 | 1.28 | 3.23 | 0.32 | 9.43 | 0.80 | 33.59 | 1.13 |
F | 26.27 | 1.29 | 3.89 | 0.44 | 7.80 | 0.28 | 24.58 | 1.37 |
G | 23.48 | 1.89 | 4.36 | 0.30 | 10.54 | 1.92 | 22.11 | 1.38 |
H | 23.22 | 2.13 | 4.15 | 0.27 | 10.17 | 0.79 | 23.79 | 1.62 |
I | 24.80 | 1.59 | 3.30 | 0.21 | 8.51 | 0.73 | 35.56 | 0.92 |
J | 25.76 | 1.16 | 3.50 | 0.52 | 7.81 | 0.44 | 27.73 | 1.10 |
K | 24.64 | 1.10 | 3.32 | 0.39 | 9.51 | 0.69 | 30.49 | 3.61 |
L | 27.04 | 1.04 | 2.88 | 0.43 | 6.84 | 0.25 | 29.02 | 2.32 |
M | 22.96 | 0.975 | 3.25 | 0.25 | 10.13 | 0.45 | 22.34 | 1.16 |
Table 8.
Mean values and standard deviations of the handfeel (HF) tests data for all the industrial base tissue papers.
HF |
||||||
---|---|---|---|---|---|---|
Top |
Bottom |
Global |
||||
Base paper | ±σ | ±σ | ±σ | |||
A | 59.1 | 3.4 | 49.5 | 2.3 | 54.3 | 5.7 |
B | 54.2 | 3.6 | 52.7 | 3.2 | 53.5 | 3.3 |
C | 71.3 | 1.5 | 67.7 | 1.9 | 69.5 | 2.5 |
D | 67.4 | 2.8 | 61.1 | 1.7 | 64.3 | 4.0 |
E | 74.7 | 1.7 | 67.6 | 2.6 | 71.2 | 4.3 |
F | 73.2 | 1.8 | 64.3 | 2.3 | 68.7 | 5.1 |
G | 73.1 | 0.9 | 71.0 | 0.6 | 72.1 | 1.3 |
H | 71.5 | 1.9 | 68.6 | 1.7 | 70.0 | 2.3 |
I | 71.4 | 1.6 | 71.0 | 4.0 | 71.2 | 2.9 |
J | 72.3 | 4.3 | 64.9 | 2.9 | 68.6 | 5.2 |
K | 63.0 | 4.7 | 63.0 | 2.6 | 63.0 | 3.6 |
L | 72.3 | 2.7 | 69.4 | 1.7 | 70.9 | 2.6 |
M | 74.2 | 1.9 | 65.2 | 1.6 | 69.7 | 5.0 |
Table 9.
Mean values and standard deviations of the TSA parameters tests data for all the industrial base tissue papers.
TS7 Parameter |
||||||
---|---|---|---|---|---|---|
Top |
Bottom |
Global |
||||
Base paper | ±σ | ±σ | ±σ | |||
A | 25.6 | 1.8 | 30.7 | 1.2 | 28.2 | 3.0 |
B | 27.9 | 1.9 | 28.7 | 1.7 | 28.3 | 1.8 |
C | 19.6 | 0.8 | 21.4 | 1.0 | 20.5 | 1.3 |
D | 21.7 | 1.4 | 24.9 | 0.9 | 23.3 | 2.1 |
E | 18.0 | 0.9 | 21.7 | 1.3 | 19.9 | 2.2 |
F | 18.5 | 0.9 | 23.2 | 1.2 | 20.8 | 2.6 |
G | 18.8 | 0.4 | 20.0 | 0.3 | 19.4 | 0.7 |
H | 19.7 | 1.0 | 21.2 | 0.8 | 20.4 | 1.1 |
I | 19.8 | 0.8 | 20.1 | 2.0 | 20.0 | 1.5 |
J | 19.4 | 2.2 | 23.2 | 1.5 | 21.3 | 2.7 |
K | 24.2 | 2.4 | 24.2 | 1.4 | 24.2 | 1.8 |
L | 18.9 | 1.4 | 20.5 | 0.9 | 19.7 | 1.4 |
M | 17.8 | 1.0 | 22.5 | 0.8 | 20.1 | 2.6 |
Table 10.
Mean values and standard deviations of the TSA parameters tests data for all the industrial base tissue papers.
TS750 Parameter |
fTS750 Parameter (Hz) |
|||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Top |
Bottom |
Global |
Top |
Bottom |
Global |
|||||||
Base paper | ±σ | ±σ | ±σ | ±σ | ±σ | ±σ | ||||||
A | 18.3 | 1.1 | 32.7 | 1.8 | 25.5 | 7.7 | 399.8 | 55.4 | 397.8 | 30.8 | 398.8 | 42.3 |
B | 23.9 | 1.4 | 31.1 | 2.0 | 27.5 | 4.1 | 540.0 | 50.8 | 446.4 | 46.8 | 493.2 | 67.5 |
C | 15.1 | 0.5 | 17.4 | 1.1 | 16.2 | 1.4 | 800.2 | 40.9 | 785.0 | 45.2 | 792.6 | 41.5 |
D | 16.4 | 0.6 | 18.3 | 0.2 | 17.3 | 1.1 | 861.8 | 46.5 | 828.0 | 122.8 | 844.9 | 89.3 |
E | 11.8 | 0.2 | 16.9 | 1.2 | 14.3 | 2.8 | 947.6 | 29.2 | 829.0 | 61.4 | 888.3 | 77.2 |
F | 13.0 | 0.6 | 18.4 | 1.0 | 15.7 | 2.9 | 841.8 | 17.2 | 658.4 | 36.6 | 750.1 | 100.3 |
G | 15.1 | 0.7 | 15.3 | 0.9 | 15.2 | 0.8 | 806.6 | 52.9 | 821.8 | 78.5 | 814.2 | 63.6 |
H | 15.4 | 0.7 | 16.5 | 0.6 | 15.9 | 0.8 | 805.8 | 35.3 | 827.2 | 46.8 | 816.5 | 40.6 |
I | 15.9 | 1.0 | 13.1 | 1.4 | 14.5 | 1.9 | 910.4 | 31.9 | 969.2 | 41.7 | 939.8 | 46.8 |
J | 13.0 | 1.2 | 17.2 | 0.4 | 15.1 | 2.4 | 950.2 | 38.1 | 878.6 | 63.5 | 914.4 | 62.1 |
K | 17.0 | 1.1 | 18.5 | 0.8 | 17.8 | 1.2 | 759.0 | 76.5 | 869.8 | 49.9 | 814.4 | 84.4 |
L | 14.7 | 0.7 | 20.5 | 0.6 | 17.6 | 3.1 | 773.8 | 49.1 | 594.0 | 84.5 | 683.9 | 115.0 |
M | 15.8 | 0.9 | 19.1 | 0.6 | 17.4 | 1.9 | 749.0 | 60.2 | 736.0 | 116.0 | 742.5 | 87.4 |
Table 11.
Mean values and standard deviations of the TSA parameters tests data for all the industrial base tissue papers.
D Parameter (mm/N) |
P Parameter (μm) |
|||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Top |
Bottom |
Global |
Top |
Bottom |
Global |
|||||||
Base paper | ±σ | ±σ | ±σ | ±σ | ±σ | ±σ | ||||||
A | 2.0 | 0.0 | 2.1 | 0.0 | 2.0 | 0.0 | -30.2 | 9.5 | -50.1 | 5.1 | -40.2 | 12.7 |
B | 2.0 | 0.1 | 2.1 | 0.0 | 2.1 | 0.1 | -17.8 | 5.3 | -34.6 | 9.9 | -26.2 | 11.6 |
C | 2.4 | 0.0 | 2.5 | 0.0 | 2.4 | 0.0 | -28.2 | 10.9 | -47.3 | 12.4 | -37.8 | 14.9 |
D | 2.2 | 0.0 | 2.2 | 0.0 | 2.2 | 0.0 | -20.9 | 6.4 | -24.8 | 12.6 | -22.9 | 9.7 |
E | 2.4 | 0.0 | 2.4 | 0.0 | 2.4 | 0.0 | -30.1 | 4.8 | -54.2 | 19.1 | -42.2 | 18.2 |
F | 2.5 | 0.0 | 2.5 | 0.0 | 2.5 | 0.0 | -48.4 | 6.3 | -52.8 | 8.4 | -50.6 | 7.4 |
G | 2.4 | 0.1 | 2.5 | 0.0 | 2.5 | 0.1 | -22.9 | 12.5 | -38.7 | 3.8 | -30.8 | 12.1 |
H | 2.5 | 0.0 | 2.4 | 0.1 | 2.5 | 0.1 | -38.8 | 12.7 | -20.2 | 7.0 | -29.5 | 13.8 |
I | 2.4 | 0.0 | 2.5 | 0.1 | 2.5 | 0.1 | -30.6 | 6.3 | -48.9 | 11.8 | -39.8 | 13.1 |
J | 2.6 | 0.1 | 2.5 | 0.0 | 2.6 | 0.1 | -53.5 | 13.8 | -62.5 | 11.4 | -58.0 | 12.8 |
K | 2.5 | 0.1 | 2.4 | 0.0 | 2.4 | 0.0 | -52.6 | 16.0 | -49.8 | 6.9 | -51.2 | 11.7 |
L | 2.6 | 0.1 | 2.6 | 0.0 | 2.6 | 0.0 | -105.2 | 14.8 | -119.0 | 17.6 | -112.1 | 17.0 |
M | 2.5 | 0.0 | 2.5 | 0.0 | 2.5 | 0.0 | -85.0 | 20.4 | -91.3 | 11.5 | -88.2 | 16.0 |
Table 12.
Mean values and standard deviations of the TSA parameters tests data for all the industrial base tissue papers.
H Parameter (J) |
E Parameter (mm/N) |
|||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Top |
Bottom |
Global |
Top |
Bottom |
Global |
|||||||
Base paper | ±σ | ±σ | ±σ | ±σ | ±σ | ±σ | ||||||
A | 28.2 | 11.7 | 29.6 | 6.6 | 28.9 | 9.0 | 2.0 | 0.0 | 2.0 | 0.0 | 2.0 | 0.0 |
B | 26.7 | 6.0 | 23.5 | 14.1 | 25.1 | 10.4 | 2.0 | 0.1 | 2.1 | 0.0 | 2.1 | 0.1 |
C | 26.8 | 7.9 | 29.7 | 9.5 | 28.3 | 8.4 | 2.4 | 0.0 | 2.5 | 0.0 | 2.4 | 0.0 |
D | 22.2 | 6.6 | 22.8 | 10.1 | 22.5 | 8.0 | 2.2 | 0.0 | 2.2 | 0.0 | 2.2 | 0.0 |
E | 27.7 | 6.8 | 28.3 | 9.2 | 28.0 | 7.6 | 2.4 | 0.0 | 2.4 | 0.0 | 2.4 | 0.0 |
F | 30.7 | 7.2 | 27.3 | 6.6 | 29.0 | 6.8 | 2.5 | 0.0 | 2.5 | 0.0 | 2.5 | 0.0 |
G | 19.6 | 13.4 | 26.3 | 10.0 | 22.9 | 11.7 | 2.4 | 0.1 | 2.6 | 0.0 | 2.5 | 0.1 |
H | 23.5 | 11.2 | 13.8 | 6.2 | 18.7 | 10.0 | 2.5 | 0.0 | 2.4 | 0.1 | 2.5 | 0.1 |
I | 20.6 | 5.7 | 28.6 | 6.1 | 24.6 | 6.9 | 2.4 | 0.0 | 2.5 | 0.1 | 2.5 | 0.1 |
J | 33.7 | 7.5 | 31.3 | 7.9 | 32.5 | 7.4 | 2.6 | 0.0 | 2.5 | 0.0 | 2.6 | 0.0 |
K | 29.7 | 5.7 | 30.2 | 7.4 | 30.0 | 6.2 | 2.4 | 0.1 | 2.4 | 0.0 | 2.4 | 0.0 |
L | 36.0 | 3.6 | 35.4 | 4.0 | 35.7 | 3.6 | 2.5 | 0.0 | 2.5 | 0.0 | 2.5 | 0.0 |
M | 34.8 | 7.6 | 37.8 | 6.5 | 36.3 | 6.9 | 2.4 | 0.0 | 2.4 | 0.0 | 2.4 | 0.0 |
2. Experimental Design, Materials and Methods
An extensive characterization of the 13 different samples of the industrial base tissue papers was carried out, using different methods. We started by determining the grammage, thickness and bulk. The grammage, expressed in g/m2 was determined in accordance with ISO 12625-6:2005 [5] and using a Mettler Toledo PB303 Delta Range analytical balance. The thickness was also determined using a FRANK-TPI® Micrometer according to ISO 12625-3:2014 [6]. Finally, the bulk, could be determined using the same standard as before, since it is the inverse of density. The morphology of all base papers was evaluated using the MORFI® Fiber and Shive Analyser from Techpap SAS, that provides us the quantity of fibers in the structure, fiber length and width, coarseness, kink fibers, curl, broken ends and fines percentage in area [7]. The Apparent porosity (theoretical) was determined, for all the industrial base tissue papers samples, using Eq. 1,
(1) |
where is the density of the cellulose (which is assumed to be 1.6 g/cm3) and is the density of the sample (g/cm3), which is the inverse of the bulk (cm3/g) [4]. The porosity was determined using a Micromeritics AccuPyc II 1340 helium pycnometer for all the samples too. The water absorption time and the water absorption capacity was measured according to ISO 12625-8:2010 [8]using a FRANK-TPI® tissue absorption tester to apply the immersion method. The industrial base tissue paper samples were cut, doing an adaptation to the above standard, with the dimensions, width 76±1 mm and length 100±1 mm, in the machine direction, since the toilet base paper does not have a defined service length. Tensile tests were done in machine and cross directions (MD and CD) for all the samples, according with ISO 12625-4:2005 [9], on a Thwing-Albert® VantageNX Universal Testing Machine. For the measurements of HF, TS7, TS750, fTS750, D, P, H, and E, the Tissue Softness Analyzer (TSA) from EMTEC was used [10]. The handfeel (HF) is one of the parameters calculated by the TSA combining several measurements of the samples to obtain a global quantification of softness of the papers. In this case the QA I algorithm was used for the calculation of the HF. All the toilet base paper samples were prepared accordingly with the machine specifications.
Declaration of Competing Interest
The authors declare that they have no known competing financial interests or personal relationships which have, or could be perceived to have, influenced the work reported in this article.
Acknowledgments
This work was carried out under the Project InPaCTus – Innovative Products and Technologies from Eucalyptus, Project N° 21874, funded by Portugal 2020 through European Regional Development Fund (ERDFin the frame of COMPETE 2020 N° 246/AXIS II/2017) .
Footnotes
Supplementary material associated with this article can be found in the online version at doi:10.1016/j.dib.2020.106434.
Appendix. Supplementary Materials
References
- 1.Raunio Simulation of creping pattern in tissue paper. Nordic Pulp Paper Res. J. 2012;27:375–381. doi: 10.3183/NPPRJ-2012-27-02-p375-381. [DOI] [Google Scholar]
- 2.Anukul P., Khantayanuwong S., Somboon P. Development of laboratory wet creping method to evaluate and control pulp quality for tissue. TAPPI J. 2015;14:7. [Google Scholar]
- 3.Ramasubramanian M.K., Shmagin D.L. An experimental investigation of the creping process in low-density paper manufacturing. J. Manuf. Sci. Eng. 2000;122:576. doi: 10.1115/1.1285908. [DOI] [Google Scholar]
- 4.J.C. Vieira, A. de O. Mendes, A.M. Carta, E. Galli, P.T. Fiadeiro, A.P. Costa, Impact of Embossing on Liquid Absorption of Toilet Tissue Papers. 15 (2020) 3888–3898. doi: 10.15376/biores.15.2.3888-3898. [DOI]
- 5.ISO 12625-6:2005 Tissue Paper and Tissue Products - Part 6: Determination of Grammage (2005).
- 6.ISO 12625-3:2014 Tissue Paper and Tissue Products - Part 3: Determination of Thickness, Bulking Thickness and Apparent Bulk Density and Bulk, (2014).
- 7.Tourtollet G., Cottin F., Cochaux A., Petit-Conil M. International Mechanical Pulping Conference, Quebec City, Canada, 2-5 June. 2003. The use of MorFi analyser to characterise mechanical pulps; pp. 225–232. [Google Scholar]
- 8.ISO 12625-8:2010 Tissue Paper and Tissue Products - Part 8: Water-absorption Time and Water-absorption Capacity, Basket-immersion Test Method, (2010).
- 9.ISO 12625-4:2005 Tissue Paper and Tissue Products - Part 4: Determination of tensile strength, stretch at break and tensile energy absorption, (2005).
- 10.EMTEC Innovative Testing Solutions “TSA - Tissue softness analyzer,” https://www.emtec-electronic.de/en/tsa-tissue-softness-analyzer.html, 2018 (accessed on June 7, 2018).
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.