Abstract
In order to improve the efficiency of disease diagnosis and environmental monitoring, it is desirable to detect the concentration of proteins and metal ions simultaneously, since the current popular diagnostic platform can only detect proteins or metal ions independently. In this work, we developed a colorimetric microfluidic paper-based analytical device (µPAD) for simultaneous determination of protein (bovine serum albumin, BSA) and metal ions [Fe(III) and Ni(II)]. The µPAD consisted of one central zone, ten reaction zones and ten detection zones in one device, in which reaction solutions were effectively optimized for different types of chromogenic reactions. Fe(III), Ni(II) and BSA can be easily identified by the colored products, and their concentrations are in good accordance with color depth based on the established standard curves. The detection limits are 0.1 mM for Fe(III), 0.5 mM for Ni(II) and 1µM for BSA, respectively. Best of all, we demonstrated the efficiency of the µPAD with accurate detection of Fe(III), Ni (II) and BSA from river water samples within 15 minutes. The µPAD detection is efficient, instrument-free, and easy-to-use, holding great potential for simultaneous detection of cross type analytes in numerous diagnostic fields.
Keywords: Microfluidic paper-based analytical device, Colorimetric detection, Simultaneous, Fe(III), Ni(II), BSA
Introduction
Proteins and metal ions are vital in life processes1–2. However, excessive intake of these essential biomolecules can lead to various diseases. For example, excess proteins can hinder functions of liver and kidney,3 the accumulation of iron increases the risk of anemia in the human body4, and a high level of nickel causes a variety of cancers5. Therefore, efficient monitoring proteins and metal ions is urgently needed for human health.6 Many methods have been used to detect the proteins and metal ions in drinking water, food and biological fluids7–11. For instance, the enzyme-linked immunosorbent assay (ELISA) can determine proteins sensitively12, inductively coupled plasma atomic emission spectrometry (ICP-AES) detects multiple metal ions at very low detection limits13–14, the liquid crystal-based chemical sensors is currently explored for detection of multiple metal ions effectively15 and the chromatography is able to determine multiple metal ions or proteins individually16–17. However, these techniques require not only expensive instruments but also fail to execute the simultaneous detection of cross type analytes at a time.
In the recent ten years, µPADs (microfluidic paper-based analytical devices) coupled with colorimetric assay are particularly attractive due to the instrument-free and easy-to-use features18–20. The specific chromogenic reactions in µPADs provide high-contrast color signal, so qualitative analysis is easy to realize by naked eyes21. Sensitive quantified measurements can be further accomplished through daily smartphone, iPad or digital camera, combined with the supporting software22. For instance, Jayawardane et al. performed 15 replicate colorimetric measurements of reactive phosphate on a single µPAD23. Fang Li et al. reported a µPAD for multiplexed colorimetric determination of six metal ions together24. S. Teepoo et al. reported a µPAD for simultaneous colorimetric detection of sucrose, fructose and glucose25. Unfortunately, these previous colorimetric detections were still limited to a single type of molecules such as macro molecules or micro molecules in one device. In fact, the simultaneous determination of two different types of chemical contaminants was realized in food by using μPADs technology, but it must be combined with fluorescence and rely on special complex instruments and trained personnel26.
In this work, a simple, rapid and effective colorimetric method is developed for the simultaneous detection of Fe(III), Ni(II) and BSA, as shown in Scheme 1. The assay combines a μPAD with different types of chromogenic reactions in a device. Four patterns were first designed to array in one mask, and then both the photoresist type and the spin coating speed were optimized for the proper volume of flow passage in a μPAD. What’s more, the injection interval time of reaction solution was optimized for simultaneous detection. According to the color palette, each color represent corresponding target, while the varying color depth corresponds to changing concentration. The calibration curves were further generated by drawing the color intensity as a function of concentration. Best of all, the convenience and efficiency of our device were verified by applying it to the detection of Fe(III), Ni(II) and BSA in natural river samples.
Scheme 1.

Schematic of the µPAD for simultaneous multiplexed detection of Fe(III), Ni(II) and BSA.
Results and Discussion
Effective Control of the Flow Passage Volume
Suitable volume of flow passage is necessary for simultaneous detection of macro and micro molecules. The volume of flow passage is well-controlled by optimizing the thickness of photoresist in two steps. Firstly, photoresist types should be selected carefully. The photoresist SU-8 3050 was too sticky to spread uniformly on paper and the photoresist SU8 1050 was too thin to provide enough volume of flow passage, so SU8 GM-1075 was selected and verified in the subsequent experiment. Secondly, photoresist should be spun at a suitable speed. 1700 rpm was selected for spin coating and the thickness of photoresist obtained was 100 ± 10 μm (Figure 1), while in Whites’ method the filter paper was soaked in the photoresist and the thickness of photoresist was not controlled27–28. Compared with other fabrication methods such as wax printing and inkjet printing29–32, UV exposure method has the advantage of effectively controlling the flow passage volume by selecting the appropriate SU-8 photoresist type and spin coating speed.
Figure 1.

Main steps of fabricating µPADs by UV-exposure method.
Optimization of the Injection Interval Time of Reaction Solution
To achieve the best performance of the μPAD for simultaneous detection of Fe(III), Ni(II) and BSA, the injection interval time for each detection was optimized as shown in Figure 2. For the detection of Fe(III), after reaction mixture solution 1 diffused and infiltrated naturally into the detection zone for 1 min, phenanthroline can drop into the detection zone, so that the chromogenic reaction can be fully carried out. For the detection of Ni(II), the optimum injection interval time between the reaction mixture solution 2 and DMG solution was 5 min, which was the appropriate time for diffusion and permeation into the detection zone. The long time led to evaporation of the solution, while the short time made the solution difficult to penetrate completely. For the detection of BSA, the injection interval time of 3 mins was a key factor for the diffusion and immersion of reaction mixture solution 3 into the detection zone, and then tetrabromophenyl blue was introduced to the detection zone.
Figure 2.

The injection process and interval time of reaction mixture and colorimetric reagent for detection of Fe(III), Ni(II) and BSA.
Colorimetric Palettes for Simultaneous Detection of Fe(III), Ni(II) and BSA
For the detection of Fe(III), 1,10-phenanthroline was used as the colorimetric reagent that reacted with Fe(II) forming an orange complex. Hydroxylammonium chloride was first served as the reductant to reduce Fe(III) to Fe(II) and also as the masking agent to complex possible interfering metals Ni, Zn Cd and Co33. Ammonium acetate provided the acid environment for the chromogenic reaction. For the detection of Ni(II), dimethylglyoxime was used as the colorimetric reagent that reacted with Ni(II) producing a pink complex. Sodium fluoride and acetic acid masked the interference from Fe(III) and Co(II), and ammonium hydroxide solution provided pH 9.0 environment for chromogenic reaction34. For the detection of BSA, tetrabromophenyl blue was used as the chromogenic reagent that reacted with BSA forming a green complex27. Sodium citrate buffer and hydrochloric acid solution provided pH 1.8–2.0 environment for chromogenic reaction.
The simultaneous detection result is displayed in Figure 3. For the first device (Figure 3a), detection zones 1–3 exhibited weak, light and bright orange, corresponding to 0.1, 0.7 and 5 mM Fe(III). Detection zones 4–6 showed weak, light and dark pink, corresponding to 0.5, 5 and 50 mM Ni(II). Detection zones 7–9 displayed dots of green, shallow and deep green, corresponding to 0.001, 0.03 and 0.1mM BSA. The detection area 10 displayed yellow as the control zone.
Figure 3.

Color palettes for visual simultaneous determination of Fe(III), Ni(II) and BSA. (a) Chromogenic reactions for 0.1, 0.7 and 5 mM Fe(III), 0.5, 5 and 50 mM Ni(II), 0.001, 0.03 and 0.1mM BSA. (b) Chromogenic reactions for 0.3, 1 and 10 mM Fe(III), 1, 10 and 100 mM Ni(II), 0.005, 0.05 and 0.15 mM BSA. (c) Chromogenic reactions for 0.5, 3 and 17.9 mM Fe(III), 2, 20 and 200 mM Ni(II), 0.01, 0.07 and 0.2 mM BSA. Yellow corresponds to 0 mM BSA as control.
Based on the result of the first device, the second and third devices were used to explore the concentration in a wider and finer range. The color palette in the second device is displayed in Figure 3b. Detection zones 1–3 exhibited light to dark orange, corresponding to 0.3 to 10 mM Fe(III). Detection zones 4–6 showed light pink to rose red, corresponding to 1 to 100 mM Ni(II). Detection zones 7–9 displayed shallow to dark green, and the color deepened with the increase of the concentration of BSA from 0.005 to 0.15 mM. The detection result of the third chip is shown in Figure 3c. In accordance with the color change trend of the front two devices, the color in the third device was still deepened as the concentration increased. Thus color palettes provide a quick and rough qualitative analysis, and the following calibration curves are required for the further quantitative systematic analysis.
Generation of Calibration Curves for Fe(III), Ni(II) and BSA
Calibration curves for Fe(III), Ni(II) and BSA are shown in Figure 4. The unit of μM was chosen to make sure the value on abscissa axis being positive. It can be found that the relationship between color intensity and logarithmic concentration behaved good linear in wide dynamic ranges. For the detection of Fe(III), the linear range was 0.1–5 mM and detection limit was 0.1 mM, respectively. For the detection of Ni(II), the linear range and detection limit were 1–50 mM and 0.5 mM, respectively. For the detection of BSA, the linear range was 1–100 μM and detection limit was 1μM. The detection range of our μPAD is very wide, which make it great potential in the water pollution detection.
Figure 4.

Calibration curves between color intensity and log target concentration for (a) Fe(III), (b) Ni(II), and (c) BSA detection. The error bars present standard deviation (SD) obtained from three independent measurement (n=3).
Interference Study
Na(I), Co(II), Mg(II), Ca(II), Cd(II), Al(III) were chosen as typical interference ions. We investigated the color intensity of mixtures containing Fe(III), Ni(II), BSA and the six interference ions. The concentration of each interfering ion was 2 mM, and the concentrations of Fe(III), Ni(II) and BSA were 1 mM, 5 mM, 0.03 mM, respectively. We also studied the color intensity of analytes of Fe(III), Ni(II), BSA. Then the comparative results were shown in Figure 5. As expected, the color intensity of each analyte was similar to that of mixtures including analyte and interference ions, while the color intensity of the interferences was very low. This suggested that the interference ions had little effect on the colorimetric detection. Thus, the fabricated μPADs possessed high selectivity and could be applied for the simultaneous detection of Fe(III), Ni(II), and BSA. Such high selectivity was the result of the masking effect of masking reagents, the selectivity of chromogenic reagents, and the specific reaction conditions optimized for the detection of each metal ion and BSA.
Figure 5.

Interference study of the microfluidic paper-based analytical device. 1 BSA detection zone, 2 Fe(III) detection zone, 3 Ni(II) detection zone.
Repeatability and Stability of the µPAD
We studied the repeatability and reproducibility on the developed μPAD. The repeatability of the assay was evaluated by averaging 3 replicate analyses of 0.3 mM Fe(III), 1mM Ni(II) and 0.05 mM BSA and calculating the relative standard deviation (%RSD). The %RSD was 1.6 for Fe(III), 3 for Ni(II) and 1.4 for BSA. The reproducibility of the devices was analyzed by using 3 different μPADs for their detections of 0.1 mM Fe(III), 5 mM Ni(II) and 0.03 mM BSA, and the RSD values obtained were 1.27%, 3.4% and 2.4% for Fe(III), Ni(II) and BSA, respectively. All the results showed that the proposed μPADs had high accuracy.
The storage stability of the μPAD was tested by measuring the change of color intensity in a period of time. The color intensities of samples were 80, 75 and 83% of initial values of Fe(III), Ni(II) and BSA, respectively, after a storage period of 3 months at room temperature and dark conditions.
Application to Actual River Samples
In order to evaluate the performance of μPAD in practical applications, river samples were analyzed by our device. Firstly, reaction mixture solutions were introduced into reaction zones 1–9. Secondly, colorimetric reagents were dropped into detection zones 1–9 respectively. Injection details were the same as described in method part. Thirdly, 30 μl river water sample was added to the center zone of the prepared μPADs. Note, the detection zone 10 was used as a control zone. It took only 15 mins from the addition of various reaction solutions to the end of the detection. As shown in Figure 6, the color of detection zones 7–9 changed from yellow to dark green, indicating the presence of BSA residues in the sample. According to the established color palettes and calibration curves respectively, the concentration of BSA in the sample was about 0.1 mM. There was no color change in detection zones 1–6, indicating no heavy metal ions Fe(III) or Ni(II) within the detection range in the sample. Accordingly, it can be quantitatively concluded that the river water was safe in the level of Fe(III) or Ni(II).
Figure 6.

Simultaneous detection of Fe(III), Ni(II) and BSA in an actual river sample (a) µPAD with reaction mixture solutions and colorimetric reagents added. (b) µPAD showing detection of an actual river sample.
In views of actual applications compared with chromatography16–17, our colorimetric analysis35–40 based on μPAD shows many advantages. Firstly, the amount of reagents used for one sample detection is within 100 μl, while the chromatography method needs about 100 ml. Secondly, the average analysis time is within 15 mins, while the compared method needs 30 mins. Thirdly, the operation part of our method is to inject drops with a liquid gun, while the chromatography method needs special skills in the operation of instrument. Fourthly, the size of a μPAD is about 2.5 × 2.5 cm and the weight is within 100 g, which is easier to carry to the real environment comparing to carry chromatographic equipment. Finally, the cost of fabricating a device and analyzing a sample is about $10 for our method, while the cost is high by a chromatography method.
Conclusions
In this work, simultaneous determination of protein and metal ions was performed using a cheaper, simpler, faster, more portable, and easier to use method, compared to the conventional method. To the best of our knowledge, this is the first simultaneous detection of Fe(III), Ni(II) and BSA based on a μPAD. High-contrast color palettes were obtained by optimizing the volume of μPAD and parameters of reaction solution. The reproducible log-linear calibration curves were further established correlating color intensity with concentrations of analytes. The limits of detection are 0.1 mM for Fe(III), 0.5 mM for Ni(II) and 1μM for BSA. The linear ranges are 0.1 to 5 mM for Fe(III), 1–50 mM for Ni(II) and 1–100 μM for BSA. The accuracy and stability of the method were evaluated in a satisfied result. We verified that the μPAD can effectively detect the content of Fe(III), Ni(II) and BSA in the natural water sample. Therefore, the proposed colorimetric μPADs open the door for simultaneous detection of cross type samples in numerous diagnostic fields.
Materials and Methods
Chemicals and Materials
Iron (III) standard solution (17.9 mM), Nickel (II) sulfate hexahydrate and Na(I), Co(II), Mg(II), Ca(II), Cd(II), Al(III) standard solution were purchased from Sigma-Aldrich Corp. Bovine serum albumin (BSA), phenanthroline, dimethylglyoxime (DMG), tetrabromophenol blue (TBPB), hydroxylammonium chloride, ammomium acetate, sodium fluoride (NaF), sodium citrate, ammonium hydroxide and hydrochloric acid were purchased from Aladdin Industrial Corp. All reagents used in the experiment were analytical grade. 2 mM TBPB and 2 mg/ml DMG solution were prepared individually with ethanol. 0.156 g/ml hydroxylammonium chloride solution, 0.48 mg/ml ammomium acetate solution, 0.5 M NaF and 10 mM sodium citrate buffer solution were diluted with ultrapure water. Reaction mixture solution 1 was prepared by mixing ammonium acetate and hydroxylammonium chloride solution at 1:1 for Fe(III) detection. Reaction mixture solution 2 was made by mixing sodium fluoride, acetic acid and ammonium hydroxide solution at 2:1:4 for Ni(II) detection. Reaction mixture solution
3 was obtained by mixing sodium citrate and hydrochloric acid at 1:1 for BSA detection. The standard solutions (0.1–17.9 mM Fe(III), 0.5–200 mM Ni(II) and 0.001–0.2 mM BSA) were prepared by diluting purchased mother liquor with ultrapure water. The river water samples were collected from the Wo River in Henan province of China.
Whatman grade 1 filter paper was purchased from Whatman International Ltd. SU-8 GM-1075 was purchased from Gersteltec Corp. Ultrapure water was obtained from a minipore water purification system. The commercial UV exposure machine (Carl Suss MA6, Germany) and plasma degumming machine (PVA Tepla, Germany) were used to fabricate the paper-based device.
Design and Fabrication of µPADs
Patterns of μPADs were drawn by L-edit software. As shown in Figure 1, four μPADs were designed and arrayed in one mask and each μPAD consisted of a centre zone (10 mm diameter), 10 reaction zones (3 mm diameter for each zone) and 10 detection zones (2.5 mm diameter for each zone) connected through narrow channels. The channel length between the reaction and center zone was 1 cm, and the channel length between the reaction and detection zone was 3 cm. 10 reaction zones and 10 detection zones were designed for simultaneous assay of Fe(III), Ni(II) and BSA in different concentrations.
The μPAD was fabricated by UV-exposure method referred by Whites27–28. The main processes of fabrication are shown in Figure 1. Firstly we cut a whatman1 paper into the shape of 4- inch silicon wafer and poured about 20 ml of SU-8 GM-1075 onto the paper fixed on a clean silicon wafer. Secondly the paper was coated with photoresist at 1700 rpm for 100 s and prebaked at 40°C for 30 min and at 120°C for 2 min. Afterwards, the photoresist was exposed to 365 nm UV light by UV exposure machine for 6 s and baked at 95°C for 30 min. Next, the unpolymerized photoresist was removed by soaking the paper in PGMEA for 3 min and by rinsing the pattern with isopropyl alcohol for 1 min. Then the surface was exposed to oxygen plasma for 60 s with 150 W plasma power by plasma degumming machine. Finally, the back of the paper surface was covered with packing tapes to prevent solution leakage.
Detection Procedures for µPADs
We used three μPADs for exploring the detection limit and detection range of Fe(III), Ni(II) and BSA. For the first μPAD, 3 pieces of 1.5 μl reaction mixture solution 1 for Fe(III) were added into reaction zones 1–3, respectively. 3 pieces of 1.5 μl reaction mixture solution 2 for Ni(II) were added into reaction zones 4–6, respectively. 4 pieces of 1.5 μl reaction mixture solution 3 for BSA were added into reaction zones 7–10, respectively. Next, 3 pieces of 0.5 μl phenanthroline solutions were dropped into detection zones 1–3, respectively. 3 pieces of 0.5 μl DMG solutions were individually dropped into detection zones 4–6. 4 pieces of 0.5 μl tetrabromophenyl blue solutions were dropped into detection zones 7–10, respectively. Finally, standard solutions (0.1, 0.7, 5 mM Fe(III), 0.5, 5, 50 mM Ni(II) and 0.001, 0.03, 0.1 mM BSA) were introduced into detection zones 1–9, respectively. Note, the detection zone 10 was used as a control zone.
For the second and third μPADs, reaction mixture solutions and colorimetric reagents were first added in the same way as the first device. Next, for the second device, standard solutions including 0.3, 1, 10 mM Fe(III), 1, 10, 100 mM Ni(II), 0.005, 0.05, 0.15 mM BSA were individually injected into detection zones 1–9. For the third device, standard solutions including 0.5, 3, 17.9 mM Fe(III), 2, 20, 200 mM Ni(II), 0.01, 0.07, 0.2 mM BSA were added into detection zones 1–9, respectively. Note, each detection repeated above 5 times.
Establishment of Calibration Curves
After the color products were formed, μPADs dried for 1 min at room temperature and were imaged using an iPad mini camera. ImageJ software was used to convert the image to 8-bit grayscale and evaluate the color intensity. Calibration curves were established by drawing the functional relationship between the color intensity and the concentration, and used as references for actual samples detecting.
Acknowledgements
This work is funded by the National Natural Science Foundation of China (NSFC) (11734003 and 51661135026), the National Key Research and Development Program of China (2016YF A0300600 & 2016YFA0300904).
Footnotes
Conflict of Interests
The authors declare no competing financial interests.
Contributor Information
Junfeng Han, Email: pkuhjf@bit.edu.cn.
Qingfan Shi, Email: qfshi123@bit.edu.cn.
References
- 1.Nam JM, Thaxton CS, Mirkin CA. Nanoparticle-based bio-bar codes for the ultrasensitive detection of proteins. Science. 2003;301:1884–1886. doi: 10.1126/science.1088755. [DOI] [PubMed] [Google Scholar]
- 2.Liu S, Zhang X, Luo W, Wang Z, Guo X, Steigerwald ML, Fang X. Single-molecule detection of proteins using aptamer-functionalized molecular electronic devices. Angew. Chem. Int. Ed. 2011;50:2496–2502. doi: 10.1002/anie.201006469. [DOI] [PubMed] [Google Scholar]
- 3.Frank R, Hargreaves R. Clinical biomarkers in drug discovery and development. Nat. Rev. Drug Discovery. 2003;2:566–580. doi: 10.1038/nrd1130. [DOI] [PubMed] [Google Scholar]
- 4.Johnson S. Iron catalyzed oxidative damage, in spite of normal ferritin and transferrin saturation levels and its possible role in Werner’s syndrome, Parkinson’s disease, cancer, gout, rheumatoid arthritis, etc. Med. Hypotheses. 2000;55:242–244. doi: 10.1054/mehy.2000.1052. [DOI] [PubMed] [Google Scholar]
- 5.Shi Z. Nickel carbonyl: toxicity and human health. Sci. Total Environ. 1994;148:293–298. doi: 10.1016/0048-9697(94)90406-5. [DOI] [PubMed] [Google Scholar]
- 6.Arora M, Kiran B, Rani S, Rani A, Kaur B, Mittal N. Heavy metal accumulation in vegetables irrigated with water from different sources. Food Chem. 2008;111:811–815. doi: 10.1016/j.foodchem.2008.04.049. [DOI] [Google Scholar]
- 7.Kingsmore SF. Multiplexed protein measurement: technologies and applications of protein and antibody arrays. Nat. Rev. Drug Discovery. 2006;5:310–320. doi: 10.1038/nrd2006. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Ma H, An R, Chen L, Fu Y, Ma C, Dong X, Zhang X. A study of the photodeposition over Ti/TiO2 electrode for electrochemical detection of heavy metal ions. Electrochem. Commun. 2015;57:18–21. doi: 10.1016/j.elecom.2015.04.015. [DOI] [Google Scholar]
- 9.Posta J, Berndt H, Luo S-K, Schaldach G. High-performance flow flame atomic absorption spectrometry for automated on line separation and determination of Cr(III)/Cr(VI) and preconcentration of Cr(VI) Anal. Chem. 1993;65:2590–2595. doi: 10.1021/ac00067a008. [DOI] [Google Scholar]
- 10.Paleologos EK, Lafis SI, Tzouwara-Karayanni SM, Karayannis MI. Speciation analysis of CrIII-CrVI using flow injection analysis with fluorimetric detection. Analyst. 1998;123:1005–1009. doi: 10.1039/a707927c. [DOI] [Google Scholar]
- 11.Ullah N, Mansha M, Khan I, Qurashi I. Nanomaterial-based optical chemical sensors for the detection of heavy metals in water: recent advances and challenges. TrAC, Trends Anal. Chem. 2018;100:155–166. doi: 10.1016/j.trac.2018.01.002. [DOI] [Google Scholar]
- 12.Scott AW, Garimella V, Calabrese CM, Mirkin CA. Universal biotin-PEG-linked gold Nanoparticle probes for the simultaneous detection of nucleic acids and proteins. Bioconjugate Chem. 2017;28:203–211. doi: 10.1021/acs.bioconjchem.6b00529. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Kuhn HR, Günther D. Elemental fractionation studies in laser ablation inductively coupled plasma mass spectrometry on laser-induced brass aerosols. Anal Chem. 2003;75:747–753. doi: 10.1021/ac0259919. [DOI] [PubMed] [Google Scholar]
- 14.Wu J, Yu J, Li J, Wang J, Ying Y. Detection of metal ions by atomic emission spectroscopy from liquid-electrode discharge plasma. Spectrochim. Acta, Part B. 2007;62:1269–1272. doi: 10.1016/j.sab.2007.10.026. [DOI] [Google Scholar]
- 15.Amin N, Siddiqi HM, Lin YK, Hussain Z, Majeed N. Bovine serum albumin protein-based liquid crystal biosensors for optical detection of toxic heavy metals in water. Sensors. 2020;20:298. doi: 10.3390/s20010298. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Fredrikson M, Carlsson N-G, Almgren A, Sandberg A-S. Simultaneous and sensitive analysis of Cu, Ni, Zn, Co, Mn, and Fe in food and biological samples by ion chromatography. J. Agric. Food Chem. 2002;50:59–65. doi: 10.1021/jf010792w. [DOI] [PubMed] [Google Scholar]
- 17.Gjoka X, Schofield M, Cvetkovic A, Gantier R. Combined protein A and size exclusion high performance liquid chromatography for the single-step measurement of mAb, aggregates and host cell proteins. J. Chromatogr. B: Anal. Technol. Biomed. Life Sci. 2014;972:48–52. doi: 10.1016/j.jchromb.2014.09.017. [DOI] [PubMed] [Google Scholar]
- 18.Sriram G, Bhat MP, Patil P, Uthappa UT, Jung H-Y, Altalhi T, Kumeria T, Aminabhavi TM, Pai RK, Madhuprasad, Kurkuri MD. Paper-based microfluidic analytical devices for colorimetric detection of toxic ions: a review. TrAC, Trends Anal. Chem. 2017;93:212–227. doi: 10.1016/j.trac.2017.06.005. [DOI] [Google Scholar]
- 19.Hossain SMZ, Brennan JD. β-Galactosidase-based colorimetric paper sensor for determination of heavy metals. Anal.Chem. 2011;83:8772–8778. doi: 10.1021/ac202290d. [DOI] [PubMed] [Google Scholar]
- 20.Teengam P, Siangproh W, Tuantranont A, Vilaivan T, Chailapakul O, Henry CS. Multiplex paper-based colorimetric DNA sensor using pyrrolidinyl peptide nucleic acid-induced AgNPs aggregation for detecting MERS-CoV, MTB, and HPV oligonucleotides. Anal. Chem. 2017;89:5248–5435. doi: 10.1021/acs.analchem.7b00255. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Karita S, Kaneta T. Chelate titrations of Ca2+ and Mg2+ using microfluidic paper-based analytical devices. Anal. Chim. Acta. 2016;924:60–67. doi: 10.1016/j.aca.2016.04.019. [DOI] [PubMed] [Google Scholar]
- 22.Mentele MM, Cunningham J, Koehler K, Volckens J, Henry CS. Microfluidic paper-based analytical device for particulate metals. Anal. Chem. 2012;84:4474–4480. doi: 10.1021/ac300309c. [DOI] [PubMed] [Google Scholar]
- 23.Jayawardane BM, Wongwilai W, Grudpan K, Kolev SD, Heaven MW, Nash DM, McKelvie ID. Evaluation and application of a paper-based device for the determination of reactive phosphate in soil solution. J. Environ. Qual. 2014;43:1081–1085. doi: 10.2134/jeq2013.08.0336. [DOI] [PubMed] [Google Scholar]
- 24.Li F, Hu Y, Li Z, Liu J, Guo L, He J. Three-dimensional microfluidic paper-based device for multiplexed colorimetric detection of six metal ions combined with use of a smartphone. Anal. Bioanal. Chem. 2019;411:6497–6508. doi: 10.1007/s00216-019-02032-5. [DOI] [PubMed] [Google Scholar]
- 25.Aksorn J, Teepoo S. Development of the simultaneous colorimetric enzymatic detection of sucrose, fructose and glucose using a microfluidic paper-based analytical device. Talanta. 2020;207:120302. doi: 10.1016/j.talanta.2019.120302. [DOI] [PubMed] [Google Scholar]
- 26.Zhang Y, Zuo P, Ye BC. A low-cost and simple paper-based microfluidic device for simultaneous multiplex determination of different types of chemical contaminants in food. Biosens. Bioelectron. 2015;68:14–19. doi: 10.1016/j.bios.2014.12.042. [DOI] [PubMed] [Google Scholar]
- 27.Martinez AW, Phillips ST, Butte MJ, White-sides GM. Patterned paper as a platform for inexpensive, low-volume, portable bioassays. Angew. Chem. Int. Ed. 2007;46:1318–1320. doi: 10.1002/anie.200603817. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Martinez AW, Phillips ST, Wiley BJ, Gupta M, Whitesides GM. FLASH:A rapid method for prototyping paper-based microfluidic devices. Lab Chip. 2008;8:2146–2150. doi: 10.1039/b811135a. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Sun X, Li B, Qi A, Tian C, Han J, Shi Y, Lin B, Chen L. Improved assessment of accuracy and performance using a rotational paper based device for multiplexed detection of heavy metals. Talanta. 2018;178:426–431. doi: 10.1016/j.talanta.2017.09.059. [DOI] [PubMed] [Google Scholar]
- 30.Ding J, Li B, Chen L, Qin W. A three-dimensional origami paper-based device for potentiometric biosensing. Angew. Chem. Int. Ed. 2016;55:13033–13037. doi: 10.1002/anie.201606268. [DOI] [PubMed] [Google Scholar]
- 31.Yang M, Zhang W, Zheng W, Cao F, Jiang X. Inkjet-printed barcodes for a rapid and multiplexed paper-based assay compatible with mobile devices. Lab Chip. 2017;17:3874–3882. doi: 10.1039/C7LC00780A. [DOI] [PubMed] [Google Scholar]
- 32.Li X, Tian J, Garnier G, Shen W. Fabrication of paper-based microfluidic sensors by printing. Colloids Surf., B. 2010;76:564–570. doi: 10.1016/j.colsurfb.2009.12.023. [DOI] [PubMed] [Google Scholar]
- 33.Asano H, Shiraishi Y. Development of paper-based microfluidic analytical device for iron assay using photomask printed with 3D printer for fabrication of hydrophilic and hydrophobic zones on paper by photolithography. Anal. Chim. Acta. 2015;883:55–60. doi: 10.1016/j.aca.2015.04.014. [DOI] [PubMed] [Google Scholar]
- 34.Rattanarat P, et al. Multilayer paper-based device for colorimetric and electrochemical quantification of metals. Anal. Chem. 2014;86:3555–3562. doi: 10.1021/ac5000224. [DOI] [PubMed] [Google Scholar]
- 35.Patil P, Madhuprasad, Bhat MP, Gatti MG, Kabiri S, Altalhi T, Jung H-Y, Losic D, Kurkuri M. Chemodosimeter functionalized diatomaceous earth particles for visual detection and removal of trace mercury ions from water. Chem. Eng. J. 2017;327:725–733. doi: 10.1016/j.cej.2017.06.138. [DOI] [Google Scholar]
- 36.Wei SQ, Chen G, Jia X, Mao X, Chen T, Mao D, Zhang W, Xiong W. Exponential amplification reaction and triplex DNA mediated aggregation of gold nanoparticles for sensitive colorimetric detection of microRNA. Anal. Chim. Acta. 2020;1095:179–184. doi: 10.1016/j.aca.2019.10.020. [DOI] [PubMed] [Google Scholar]
- 37.Zhang X, Wang CY, Gao YF. Cerium(III)-doped MoS2 nanosheets with expanded interlayer spacing and peroxidase-mimicking properties for colorimetric determination of hydrogen peroxide. Microchim. Acta. 2020;187:111. doi: 10.1007/s00604-019-4078-1. [DOI] [PubMed] [Google Scholar]
- 38.Bhat MP, Madhuprasad, Patil P, Nataraj SK, Altalhi T, Jung H-Y, Losic D, Kurkuri MD. Turmeric, naturally available colorimetric receptor for quantitative detection of fluoride and iron. Chem. Eng. J. 2016;303:14–21. doi: 10.1016/j.cej.2016.05.113. [DOI] [Google Scholar]
- 39.Bhat MP, Kigga M, Govindappa H, Patil P, Jung H-Y, Yu J, Kurkuri M. A reversible fluoride chemosensor for the development of multi-input molecular logic gates. New J. Chem. 2019;43:12734–12743. doi: 10.1039/C9NJ03399H. [DOI] [Google Scholar]
- 40.Patil P, Ajeya KV, Bhat MP, Sriram G. Real-time probe for the efficient sensing of inorganic fluoride and copper ions in aqueous media. ChemistrySelect. 2018;3:11593–11600. doi: 10.1002/slct.201802411. [DOI] [Google Scholar]
