Abstract
A parabolic stress–strain constitutive model for inorganic thermal-insulating material confined by carbon fiber-reinforced polymer (CFRP) exposed to a surrounding elevated temperature was proposed in this paper. The thermal-insulating material used in this study was composed of high-early-strength cement (HESC) and perlite powder. The compression strengths of four kinds of perlite powder composition ratios of thermal-insulating materials cylindrical specimens which were confined by one, two, and three-layer CFRP composite materials were acquired. The experimental results showed that the compression strength was enhanced as the amount of perlite substitute decreased or as the number of CFRP wrapping layers increased. The Mohr–Columb failure criteria were adopted to predict the maximum compressive strength of CFRP-confined inorganic thermal-insulating material. The strain at the maximum compressive strength was found from the experimental results, and the corresponding axial strain at the maximum compressive strength in the constitutive model was determined from the regression analysis. Furthermore, the compressive strengths of the four different perlite composites of thermal-insulating materials were obtained when heating the specimens from ambient temperature to 300 °C. The compressive strength decreased with an increase in temperature, and a thermal softening parameter model was proposed; the thermal softening parameter was determined from the experimental maximum compressive strength at an elevated temperature. Combining the above two models, the constitutive model of HESC with perlite powder additive as a thermal-insulating material confined by CFRP under elevated temperature was proposed.
Keywords: high-early-strength cement, perlite, carbon fiber-reinforced polymer, constitutive model, elevated temperature
1. Introduction
Petrochemicals are critical to the development of the global industry, and low-carbon steel-made pipelines are commonly used for transporting petroleum products because they are the most cost-effective. However, these steel pipes can be corroded, especially in the presence of corrosive acids, sulfur, and chlorides. The common method of steel pipeline repair is to use carbon fiber-reinforced materials or mineral wool-reinforced materials to cover the damaged steel. However, particularly when the damaged or corroded pipelines are assembled under a high-temperature environment, the current strengthening the insulation layer wrapped in the surface of the pipeline is a difficult problem that needs to be overcome. Hence, Li et al. proposed a method to strengthen high-temperature steel pipelines, where the inorganic thermal-insulating materials confined by CFRP are used to strengthen the damaged pipelines settled in high-temperature installations, as shown in Figure 1 [1].
The advantages of the manufacturing process of the CFRP composite material are as follows: high strength, high modulus, corrosion resistance, lightweight, and easy implementation [2,3]. The epoxies are polymer chemical compounds and serve as a bonding element in the CFRP composition. When epoxy resin was exposed to high temperature environment, its mechanical properties will reduce. Therefore, a thermal-insulating material made of HESC with perlite powder additive and wrapped in CFRP on the damaged metallic pipelines was proposed, which is a solution to prolong the lifetime of damaged metallic pipelines under high temperatures. A compressive strength test was performed on specimens made of HESC with various proportions of perlite at different temperatures. This study aims to build a constitutive model of CFRP-confined thermal-insulating material under elevated temperatures.
Perlite powder is an essential material for the application of thermal insulation material. By altering the proportion of perlite additive, it was found that the compressive strength diminished with the increment in the perlite [4,5,6]. The concrete specimen was added with perlite powder, the results indicated that the compressive strength of the concrete specimen diminished while the replacement rate of perlite powder increased. In aspects of the thermal conductivity and mechanical properties of lightweight concrete, the compressive strength and elastic modulus decreased with the increment of lightweight aggregates [7,8,9,10]. Confined concrete constitutive models using FRP and steel jacketing have been researched extensively in the last few decades. The compressive strength models are proposed to calculate the maximum strength of concrete reinforced with steel plate, and fiber-reinforced plastic (FRP) composites. [11,12,13,14,15,16,17,18,19,20,21].
When concrete cylinders and reinforced concrete columns were confined by FRP composite materials, the compressive strength could be enhanced by confining with FRP composite materials [22,23,24,25,26,27]. Instead of cylindrical reinforced concrete columns, the compression strength of square columns can be improved by enclosing with CFRP composite materials as well. The compressive strength increased with the number of CFRP wraps, and the strains of CFRP-confined concrete specimens decreased with the higher inherent strength of the concrete [28]. Rousakis et al. used transversely placed basalt composite rope as an external confining reinforcement and combined this with FRP sheets for reinforced concrete columns with a square section. The results showed that the basalt composite rope could increase the axial strain sustained by the concrete from 2.21% to 5.1% without rope fracture [29,30].
As the temperature increased, the behavior of the FRP-confined and unconfined specimens would lead to the failure of the concrete confinement. However, as the compressive strength of the FRP-reinforced concrete is increased, these properties would increase the performance and the effect of the restraining factors of FRP-reinforced concrete [31,32]. Al-Salloum et al. [33] investigated the effect of high temperatures on the performance of concrete externally confined with FRP sheets. The test results showed that the bond strength of the CFRP-overlaid specimens has a significant degradation at a temperature of 200 °C. da Costa Mattos et al. [34] analyzed the glass fiber-reinforced polyurethane repair system for corroded metallic pipelines; it was shown that the water temperature (between 60 and 90 °C) was a major shortcoming in the use of polymeric material in the repair system.
2. Materials and Test Program
In the repair system shown in Figure 1, the materials consisted of HESC, expanded perlite, a carbon fiber sheet, and epoxy resin. The experimental procedures comprised compressive strength tests of thermal-insulating materials made of HESC with various ratios of perlite powder which were confined by CFRP composite materials. Therefore, the maximum compressive strength and the corresponding strain of various numbers of CFRP layers in a specific high-temperature surrounding was proposed.
2.1. Materials
HESC was manufactured by the Denka Company in Japan. The components of the HESC were analyzed by utilizing X-ray fluorescence analysis, as shown in Table 1.
Table 1.
Composition | Percentages (%) |
---|---|
CaO | 68.4 |
SiO2 | 11.9 |
Al2O3 | 9.20 |
SO2 | 5.10 |
Fe2O3 | 2.90 |
K2O | 1.80 |
TiO2 | 0.70 |
P2O5 | 0.50 |
Perlite powder is a white-in-color glassy volcanic rhyolitic lava, which can be expanded to up to 20 times the original dimensions and form a porous morphology when heated above 870 °C. It is commonly called expanded perlite and is a good insulating material due to its porosity characteristics, and it is commonly used in the fields of construction and agriculture and in the chemical industry. The perlite powder was placed on the top sieve, and the sieves were agitated in a mechanical shaker. The sieve analysis test results are shown in Table 2, and the fineness modulus is 2.97.
Table 2.
Sieve Number | Weight Retained (g) | Percent Retained | Percent Coarser Than |
---|---|---|---|
#4 | 0 | 0 | 0 |
#8 | 0 | 0 | 0 |
#16 | 106 | 0.53 | 53.27 |
#30 | 31 | 0.16 | 68.84 |
#50 | 26 | 0.13 | 81.91 |
#100 | 22 | 0.11 | 92.96 |
Pan | 2 | 0.01 | 100.00 |
Fineness modulus (F.M.) = 2.97 |
CFRP composite material is made of uni-directional carbon fiber sheet and polymer, where the carbon fiber provides a higher tensile strength and stiffness and the polymer adhesive material offers a cohesive strength to hold the fibers together. The uni-directional carbon sheet uses 12,000 carbon fiber monofilaments in a carbon fiber bundle, and its fiber area weight (FAW) is 300 g/m2. The material properties and specification of the uni-directional carbon fiber sheet and epoxy resin are listed in Table 3 and Table 4, respectively. A photo of the uni-directional CFRP sheet is shown in Figure 2.
Table 3.
Uni-directional Carbon Fiber Sheet | Specification | |
Young’s modulus | 250 (GPa) | |
Tensile strength | 4.9 (GPa) | |
Thickness | 0.16 (mm/layer) | |
Ultimate strain | 0.02 |
Table 4.
Epoxy Resin | Specification | |
Viscosity (at 25 °C) | 1823 (cps) | |
Young’s modulus | 3.5 (GPa) | |
Tensile strength | 52.2 (MPa) | |
Tensile adhesive strength | 10.5 (MPa) |
2.2. Testing Program
This study conducted compressive testing of cylindrical and cubic specimens, utilizing a 981 kN universal testing machine at the Department of Civil Engineering, National Taipei University of Technology. The compressive testing required the specimens to be placed in the universal testing machine, and a load cell (WF 17120, Wykeham Farrance, Milan, Italy) with a 490 kN capacity and strain gauges (KFGS-20-120-C1 L3M2R, KYOWA, Tokyo, Japan) were utilized. According to American Society for Testing and Materials (ASTM) C39/C39M-18 [35], the loading rate of each specimen was 900~1800 N/s. Additionally, a data acquisition system (KL-10, Geomaster Group, Tianjin, China) was used to obtain the force-displacement information during compressive testing.
Besides this, perlite powder of proportions 10, 20, and 30 wt.% was added to the HESC, and the water–cement ratio of HESC was 0.35. According to ASTM C109/C M109-02 [36], the compressive strength test was conducted on a standard cubic specimen with the dimensional aspects of 5 × 5 × 5 cm. The cubic specimen, after 28 days of curing for the compressive strength testing, was examined under various temperatures of 100, 150, 200, 250, and 300 °C. For the compressive strength test, the specimens were placed to heat up on the crucible in the furnace, then withdrawn out from the furnace immediately while we waited for the specimens to reach the above-mentioned temperature, then we started to proceed with the compressive testing.
Table 5 shows the specification of the specimen name and test method, where SPC represents the insulation material specimens with perlite mixed for compression testing, SPCC represents insulation material specimens with the perlite additive confined by CFRP composites for compression testing, and SPTC represents the insulation material specimens for compression testing under elevated temperature conditions. Table 6 shows the lists of the mixed ratios of the thermal-insulating materials.
Table 5.
Specimen | Description (Test Method) | Dimension | Perlite Ratio in Weight (%) |
---|---|---|---|
SPC | HESC with perlite (ASTM C39/C39M-18) |
Φ10 cm × 20 cm | 0; 10; 20; 30 |
SPCC | HESC with perlite confined by CFRP (ASTM C39/C39M-18) | Φ10 cm × 20 cm | |
SPTC | HESC with perlite under elevated temperature (ASTM C109/C M109-02) | 5 cm × 5 cm × 5 cm |
Table 6.
Specimen | Perlite Ratio in Weight (%) | Perlite (g) | HESC (g) | Water (g) |
---|---|---|---|---|
SPC0 | 0 | 0 | 2000 | 700 |
SPC10 | 10 | 200 | 1800 | 630 |
SPC20 | 20 | 400 | 1600 | 560 |
SPC30 | 30 | 600 | 1400 | 490 |
Table 7 lists the identification and number of cylindrical specimens. A total number of 48 cylindrical insulation material specimens were tested to obtain the compression strength of the specimens confined by different numbers of CFRP layers.
Table 7.
Specimen | Shape | No. of CFRP Layer | No. of Cylindrical Specimen |
---|---|---|---|
SPC0 | Cylinder | Nil, 1, 2, 3 | 12 |
SPCC10 | 12 | ||
SPCC20 | 12 | ||
SPCC30 | 12 |
The total number of specimens: 48.
The application procedures of the CFRP composite materials to the cylindrical specimens were as follows: Before applying the CFRP layer with a coating epoxy adhesive, we cleaned the surface of the cylinders to ensure a good adhesion at the interfaces. Firstly, we applied a thin layer of primer epoxy resin to the surface of the cylinder. After the primer epoxy resin was cured at room temperature for a few hours, a carbon fiber sheet was applied to paste onto the cylindrical specimens. The epoxy was applied by using a paintbrush layer by layer for a fully saturated infiltration on the carbon fiber. The overlapping cover length was more than 10 cm, and the next layer was applied 24 h later. After applying the desired sheet, the CFRP jacketing was cured at room temperature.
The tensile circumferential strain of CFRP was measured by strain gauges (KFGS-20-120-C1 L3M2R, Kyowa, Japan) attached to the middle surface of the CFRP-confined specimen. The concrete cylinder confined by the CFRP composites established on the compression testing instrument is shown in Figure 3.
Similarly, a total number of 72 cubical specimens (5 × 5 × 5 cm) were made to investigate the compression strength of thermal-insulating materials at different elevated temperatures, as shown in Table 8.
Table 8.
Specimen | Shape | Elevated Temperatures (°C) | No. of CFRP Cubic Specimen |
---|---|---|---|
SPTC0 | Cube | 25, 100, 150, 200, 250, 300 | 18 |
SPTC10 | 18 | ||
SPTC20 | 18 | ||
STPC30 | 18 |
The total number of specimens: 72.
3. Constitutive Model of the CFRP-Confined Thermal-Insulating Material
The following subsections will introduce the results of the compressive strength test of the thermal-insulating materials without and with CFRP confinement. The research aims at studying the effect of various amounts of perlite additive (0, 10, 20, and 30 wt.%) on the compressive strength.
3.1. Compressive Strength Test of SPCs
A series of compressive strength tests were carried out on SPC specimens to observe the changes in terms of strength related to the different structural designs with various components of the composites. Table 9 shows that the compressive strength diminishes as the addition of perlite content rises.
Table 9.
Specimen | Perlite Ratio in Weight (%) | Average Compressive Strength (MPa) | Decrease Percentage (%) |
---|---|---|---|
SPC0 | 0 | 47.25 | - |
SPC10 | 10 | 26.04 | 44.89 |
SPC20 | 20 | 17.18 | 63.64 |
SPC30 | 30 | 12.84 | 72.82 |
3.2. Compression Test on CFRP-Confined Specimens
In this subsection, the compressive strength and failure mode of the SPC and SPCC specimens confined by different layers of CFRP composite material were investigated.
3.2.1. HESC Specimens
The compression test was conducted with a cylindrical specimen without perlite as a control group. Figure 4a shows the relationship between the axial stress–axial strain relationships of the cylindrical specimens without CFRP confinement. The average maximum compressive strength of SPC0 was 42.75 MPa. The maximum compressive strength of specimens SPCC0_1, SPCC0_2, and SPCC0_3 increased by 33%, 95%, and 181%, respectively. The maximum compressive strength and corresponding strain of the specimens increased with increasing the number of CFRP wrapping layers, as shown in Figure 4b–d. In SPCC0_2. It should be noted that the strength was suddenly drop due to the partial fracture occurrence of CFRP while the loading stress was about 60 MPa.
3.2.2. HESC with Perlite Content
From the compressive test results, the average maximum compressive strength without wrapping CFRP on a cylinder consisting of 10, 20, and 30 wt.% perlite additive was 26.04, 17.18, and 12.84 MPa, respectively. As revealed in Table 10, the number of CFRP layers increased for the confined specimens; the maximum compressive strength of the confined specimens with 10, 20, and 30 wt.% of added perlite increased by 51.1~219%, 78.4~340%, and 107.6~439.1%, respectively. As the number of CFRP layers increased, especially in specimen SPCC30_3, the compressive strength increased the percentage of intensity up to 439.1%.
Table 10.
Specimen | No. of CFRP Layers | Average Maximum Compressive Strength (MPa) | Increase Percentage (%) |
---|---|---|---|
SPCC0_1 | 1 | 63.05 | 33.4 |
SPCC0_2 | 2 | 92.15 | 95.0 |
SPCC0_3 | 3 | 133.04 | 181.6 |
SPCC10_1 | 1 | 39.31 | 51.1 |
SPCC10_2 | 2 | 54.25 | 108.3 |
SPCC10_3 | 3 | 83.07 | 219.0 |
SPCC20_1 | 1 | 30.69 | 78.4 |
SPCC20_2 | 2 | 49.46 | 187.6 |
SPCC20_3 | 3 | 75.68 | 340.0 |
SPCC30_1 | 1 | 26.66 | 107.6 |
SPCC30_2 | 2 | 42.19 | 228.6 |
SPCC30_3 | 3 | 69.22 | 439.1 |
According to the test data, the maximum compressive strength of the SPCC specimens was improved due to the supported confinement of a different number of CFRP layers. As the number of CFRP layers increased for the confined specimens, no matter what the percentage of perlite additives was, the increasing percentage of maximum compressive strength could be improved. Table 11 shows the post-test photographs of SPCC specimens; it can be seen that the fracture in CFRP and the spalling in concrete are more severe as the number of confining layers increases. The measured lateral strain at the maximum compressive strength of SPCCs is listed in Table 12.
Table 11.
Specimen with Perlite Percentage (%) | 1-Layer CFRP | 2-Layer CFRP | 3-Layer CFRP |
---|---|---|---|
Without perlite (SPCC0) | |||
10% perlite (SPCC10) | |||
20% perlite (SPCC20) | |||
30% perlite (SPCC30) |
Table 12.
Strain | 1-Layer CFRP SPCC0-1 |
2-Layer CFRP SPCC0-2 |
3-Layer CFRP SPCC0-3 |
---|---|---|---|
Measured Lateral Strain (%) | 0.898 | 1.092 | 1.223 |
0.975 | 1.076 | 1.173 | |
1.186 | 1.125 | 1.159 | |
Average Lateral Strain (%) | 1.020 | 1.098 | 1.185 |
3.3. Constitutive Model for CFRP-Confined Thermal-Insulating Material
This study used both the analytical model and regression analysis of experimental data to progress a constitutive model that was appropriate for representing the compression behavior of thermal-insulating material specimens with a different number of CFRP layers. The maximum compressive strength of the thermal-insulating materials confined by CFRP was derived from the Mohr–Coulomb failure criterion; the corresponding strain at the maximum compressive strength was derived from the regression analysis of the data.
3.3.1. Compressive Stress–Strain Relationship of the Constitutive Model
The proposed parabolic constitutive model for the CFRP-confined specimens is shown in Figure 5. In rock mechanics, the Mohr–Coulomb failure criterion is often used and is expressed as the following equation:
(1) |
where is the uniaxial compressive strength of rock with lateral confinement stress, is the internal friction angle, and is the uniaxial compressive strength without lateral confinement [37].
The mechanical behavior of thermal-insulating material confined by the CFRP composite material is similar to that of rock confined by lateral water pressure. Therefore, the maximum compressive strength of the proposed model was adopted from the Mohr–Coulomb failure criterion, and can be expressed as follows:
(2) |
(3) |
Where:
f’cc = the compressive strength of the confined concretes;
f’c = the compressive strength of the unconfined concretes;
f’l = the effective lateral confined stress of CFRP;
ϕ = internal friction angle of concretes;
n = the number of CFRP wrapping layers;
t = the thickness of a single CFRP layer;
Ecf = the elastic modulus of CFRP;
εcf = the strain of CFRP;
kc = a sectional shape factor.
In this paper, the internal friction angle was proposed as follows:
(4) |
By applying Equation (3), the lateral confined stress of the CFRP confinement can be derived. The measured lateral strains of the cylindrical specimens wrapped with different numbers of CFRP sheets are listed in Table 12, and the average measured lateral strain was εcf = 1.1%. For one layer, two layers, and three layers of CFRP-confined cylindrical specimens (Φ10 cm × 20 cm), the effective lateral confined stresses were 7.84, 15.68, and 23.51 MPa, respectively.
To find the angle of internal friction, Equation (3) can be modified as follows:
(5) |
In Equation (5), a regression analysis was performed to obtain the experimental internal friction angle, ϕ, where f’l/f’c and f’cc/f’c are set as the abscissa and ordinate axes of the coordinates. The computed results are shown in Figure 6. The experimental values of the internal friction angles were 15.2°, 15.6°, and 21.7°, for the specimens confined with different layers of CFRP, as shown in Figure 6a–c, respectively.
A regression analysis was performed to derive the coefficients A and B in Equation (4), where f’c/f’l and ϕ were set as the abscissa and ordinate axes of coordinates; the values of f’c/f’l used for the analysis are listed in Table 13.
Table 13.
Perlite Ratio in Weight | |||||
---|---|---|---|---|---|
No. of CFRP Layers | 0% | 10% | 20% | 30% | |
Value | 1 | 6.03 | 3.32 | 2.19 | 1.64 |
2 | 3.01 | 1.66 | 1.10 | 0.82 | |
3 | 2.01 | 1.11 | 0.73 | 0.55 |
The results of the coefficients A and B were 19.4 and −0.95; thus, Equation (4) was rewritten as:
(6) |
By substituting the above-mentioned internal friction angles (ϕ) into Equation (2), the analytical maximum compressive strengths could be obtained. The maximum compressive strengths of the experimental and analytical results are shown in Table 14, where the average absolute error is 7.24%. Figure 7 shows the deviation between the experimental and analytical maximum compressive strengths, as well as the correlation coefficient (R2) is 0.903. The results show that the proposed constitutive model could portend the experimental maximum compressive strength with a realistic degree of accuracy.
Table 14.
Specimen | Number of CFRP Layers | Average Experimental Maximum Strength (MPa) | Analytical Maximum Strength (MPa) | Absolute Error (%) |
---|---|---|---|---|
SPCC10_1 | 1 | 39.31 | 40.80 | 3.79 |
SPCC20_1 | 1 | 30.69 | 32.54 | 6.03 |
SPCC30_1 | 1 | 26.66 | 28.50 | 6.90 |
SPCC10_2 | 2 | 54.25 | 57.33 | 5.68 |
SPCC20_2 | 2 | 49.46 | 49.10 | 0.73 |
SPCC30_2 | 2 | 42.19 | 45.08 | 6.85 |
SPCC10_3 | 3 | 83.07 | 73.90 | 11.04 |
SPCC20_3 | 3 | 75.68 | 65.68 | 13.21 |
SPCC30_3 | 3 | 69.22 | 61.66 | 10.92 |
Average absolute error (%) 7.24.
3.3.2. The Axial Strain at the Maximum Compressive Strength
As the axial stress achieves the maximum compressive strength “”, the CFRP breaks and fails to provide confinement, and the corresponding axial strain at the maximum compressive strength “” is primarily governed by the CFRP confining strength. Therefore, the analytical could be presented as the following equation.
(7) |
From the regression analysis, the parameters and α can be found, where = 0.0356 and α = 0.056. In Figure 8, the experimental data are expressed as dots which are obtained from the stress–strain relationships of specimen SPCCs, and the straight line is obtained from Equation (7). It shows that Equation (7) can anticipate the corresponding axial strain at the maximum strength by anticipating consistency as well.
Then, the compressive stress–strain relationship of the constitutive model, as shown in Figure 5, can be expressed as follows.
(8) |
In Equation (8), fc and εc are the compression stress and strain of the specimens wrapped with CFRP composite material.
4. Constitutive Model of the Thermal-Insulating Material at Elevated Temperature
The purpose of the experiment was to understand the compressive strengths of the thermal-insulating material specimens (with the addition of 0, 10, 20, and 30 wt.% perlite powder) at different temperature conditions of 25, 100, 150, 200, 250, and 300 °C. These were applied to standard cubic specimens with a size of 5 × 5 × 5. The specimens were settled on a crucible to heat in the oven. While the specimens were taken out of the furnace, the compressive strength test was performed immediately when the scheduled temperature was achieved. The thermal softening model was proposed for the maximum compressive strength. According to the experimental results, the thermal softening parameters of the maximum compressive strength were determined.
4.1. Compression Test at Elevated Temperature Conditions
The relationship of the compressive strength of the specimens with various perlite ratios and different temperatures is shown in Figure 9. The results show that the maximum compressive strength of the thermal-insulating material specimens also diminishes as the amount of perlite added rises. The maximum compressive strength was reduced by increasing the content of the perlite additive with the rising temperature.
The results showed that the weight ratio of perlite added played an important role as a thermal-insulating material for resisting the thermal transport during the elevated temperatures. For the compressive strength test at a specific temperature, although the specimen consisted of a lower compression strength with a higher proportion of perlite added, the difference in the compression strength of the specimens with perlite added for comparing between 0 wt.% and 30 wt.% decreased with the elevating temperature.
4.2. A Maximum Compressive Strength Model at Elevated Temperatures
For the maximum compressive strength of the thermal-insulating material at elevated temperatures, an exponential thermal softening model was proposed as follows [38,39]:
(9) |
where f’T and f’c are the maximum compressive strengths of the thermal-insulating material under an elevated temperature (T) and the reference temperature (Tref), respectively. In Equation (9), λ is the thermal softening parameter of the thermal-insulating materials with various perlite ratios added.
The results of the compressive strength test with various perlite ratios at different elevated temperatures were analyzed numerically via regression analysis to obtain a thermal softening parameter. Figure 10 shows the results of the regression analysis results of the thermal softening parameter of HESC with different ratios of perlite powder. The thermal softening parameters of the thermal-insulating materials obtained from the regression analysis were λ = 0.00341, 0.00238, 0.00223, and 0.00229 for perlite ratios of 0, 10, 20, and 30 wt.%, respectively.
The thermal softening material parameter of the thermal-insulating material with different perlite ratios in weight was substituted into Equation (9) to obtain the analytical maximum compressive strength. The absolute errors between the analytical and experimental maximum compressive strengths are listed in Table 15, and the average absolute errors were 5.12%, 3.13%, 3.49%, and 2.63% for perlite ratios of 0, 10, 20, and 30 wt.%, respectively. The correlation coefficients (R2) between the analytical and experimental maximum compressive strengths were found to be 0.95, 0.98, 0.98, and 0.98 for perlite ratios of 0, 10, 20, and 30 wt.%, respectively. The proposed thermal softening model, as shown in Equation (9), could predict the experimental maximum compressive strength with a reasonable degree of accuracy.
Table 15.
- | ΔT (°C) | Perlite Ratio in Weight (%) | |||
---|---|---|---|---|---|
- | 0 | 10 | 20 | 30 | |
Absolute Error (%) | 0 | 0 | 0 | 0 | |
9.10 | 5.84 | 4.08 | 2.02 | ||
6.51 | 7.51 | 1.64 | 10.01 | ||
3.96 | 4.85 | 3.78 | 11.72 | ||
8.39 | 4.57 | 5.40 | 3.56 | ||
0.99 | 1.64 | 5.34 | 5.59 | ||
Average Absolute Error (%) | - | 5.12 | 3.13 | 3.49 | 2.63 |
Correlation Coefficient (R2) | - | 0.95 | 0.98 | 0.98 | 0.98 |
5. Constitutive Model of CFRP-Confined Thermal-Insulating Material at Elevated Temperatures
This study used both the theoretical Mohr–Coulomb failure criterion and a regression analysis of the experimental data to develop a constitutive model of CFRP-confined thermal-insulating material at elevated temperatures. The maximum compressive strength of the CFRP-confined thermal-insulating materials was gained from the Mohr–Coulomb failure criterion. In the meantime, the corresponding axial strain at the maximum compressive strength was derived from the test results via regression analysis. Therefore, a parabolic stress–strain relationship constitutive model for CFRP-confined specimens was proposed, as shown in Equation (8). For the maximum compressive strength of the thermal-insulating material at elevated temperatures, a thermal softening model was proposed, as shown in Equation (9).
Eventually, the physical-based constitutive model (stress–strain relationship) for thermal-insulating material specimens wrapped with CFRP under an elevated temperature is proposed as follows.
(10) |
where fT and εc are the compression stress and strain of specimens wrapped with CFRP under elevated temperatures. Then, a parabolic stress–strain relationship of the constitutive model for CFRP-confined thermal-insulating material at elevated temperatures was proposed, as shown in Equation (10).
6. Conclusions
This study presented a constitutive model of CFRP-confined thermal-insulating material at elevated temperatures. From the experimental and regression analysis results, the following conclusions were drawn:
Based on the compressive test results, the maximum compressive strength of HESC diminished with the increment in the addition of perlite, and also decreased with elevating temperature.
From the compressive test results, the maximum compressive strength of the thermal-insulating material confined by CFRP was enhanced with an increment in the number of CFRP layers used.
For the maximum compressive strength prediction model, the average absolute error between the analytical model and the experimental maximum compressive strengths was 7.24%, and its correlation coefficient (R2) is 0.903.
For the proposed thermal softening model of the thermal-insulation specimens at elevated temperature, the average absolute errors between the analytical and experimental maximum compressive strengths errors were 5.12%, 3.13%, 3.49%, and 2.63% for perlite ratios of 0, 10, 20, and 30 wt.%, respectively. The correlation coefficients (R2) between the analytical and experimental maximum compressive strengths errors were 0.95, 0.98, 0.98, and 0.98 for perlite ratios of 0, 10, 20, and 30 wt.%, respectively.
The physics-based constitutive model for inorganic thermal-insulating material confined by CFRP exposed at a surrounding elevated temperature was proposed, and this proposed constitutive model can predict the experimental maximum compressive strength for the thermal-insulating material confined by CFRP composite materials accompanied with increasing temperature.
Author Contributions
Conceptualization, Y.-F.L.; data curation, W.-K.S.; formal analysis, W.-K.S.; investigation, W.-K.S., T.-H.Y., and Y.-K.T.; methodology, Y.-F.L. and Y.-K.T.; project administration, Y.-F.L.; supervision, Y.-F.L.; writing—original draft, W.-K.S. and T.-H.Y.; writing—review and editing, Y.-F.L. and Y.-K.T. All authors have read and agreed to the published version of the manuscript.
Funding
This research was funded by the Ministry of Science and Technology of Taiwan government, under contract no. MOST-106-2221-E-027-047, and the “Research Center of Energy Conservation for New Generation of Residential, Commercial, and Industrial Sectors” from the Ministry of Education in Taiwan under contract no. L7091101-19.
Conflicts of Interest
The authors declare no conflict of interest.
Footnotes
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Li Y.F., Yang T.H., Tsai T.H. A novel strengthening method for damaged pipeline under high temperature using inorganic insulation material and carbon fiber reinforced plastic composite material. Materials. 2019;12:3484. doi: 10.3390/ma12213484. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Bakis C.E., Bank L.C., Brown V.L., Cosenza E., Davalos J.F., Lesko J.J., Machida A., Rizkalla S.H., Triantafillou T.C. Fiber-reinforced polymer composites for construction—State-of-the-art review. J. Compos. Constr. 2002;6:73–87. doi: 10.1061/(ASCE)1090-0268(2002)6:2(73). [DOI] [Google Scholar]
- 3.Hollaway L.C. A review of the present and future utilization of FRP composites in the civil infrastructure with reference to their important in-service properties. Constr. Build. Mater. 2010;24:2419–2445. doi: 10.1016/j.conbuildmat.2010.04.062. [DOI] [Google Scholar]
- 4.Topçu I.B., Işıkdağ B. Manufacture of high heat conductivity resistant clay bricks containing perlite. Build. Environ. 2016;42:3540–3546. doi: 10.1016/j.buildenv.2006.10.016. [DOI] [Google Scholar]
- 5.Topçu I.B., Işıkdağ B. Effect of expanded perlite aggregate on the properties of lightweight concrete. J. Mater. Process. Technol. 2008;204:34–38. doi: 10.1016/j.jmatprotec.2007.10.052. [DOI] [Google Scholar]
- 6.Demirboğa R., Örüng İ., Gül R. Effect of expanded perlite aggregate and mineral admixtures on the compressive strength of low-density concretes. Cem. Concr. Res. 2001;31:1627–1632. doi: 10.1016/S0008-8846(01)00615-9. [DOI] [Google Scholar]
- 7.Ramezanianpour A.A., Karein S.M.M., Vosoughi P., Pilvar A., Isapour S., Moodi F. Effects of calcined perlite powder as a SCM on the strength and permeability of concrete. Constr. Build. Mater. 2014;66:222–228. doi: 10.1016/j.conbuildmat.2014.05.086. [DOI] [Google Scholar]
- 8.Tasdemir C., Sengul O., Tasdemir M.A. A Comparative study on the thermal conductivities and mechanical properties of lightweight concretes. Energy Build. 2017;151:469–475. doi: 10.1016/j.enbuild.2017.07.013. [DOI] [Google Scholar]
- 9.Sengul O., Azizi S., Karaosmanoglu F., Tasdemir M.A. Effect of expanded perlite on the mechanical properties and thermal conductivity of lightweight concrete. Energy Build. 2011;43:671–676. doi: 10.1016/j.enbuild.2010.11.008. [DOI] [Google Scholar]
- 10.Huang Z., Liew J.Y.R., Li W. Evaluation of compressive behavior of ultra-lightweight cement composite after high temperature exposure. Constr. Build. Mater. 2017;148:579–589. doi: 10.1016/j.conbuildmat.2017.04.121. [DOI] [Google Scholar]
- 11.Li Y.F., Lin C.T., Sung Y.Y. A constitutive model for concrete confined with carbon fiber reinforced plastics. Mech. Mater. 2003;35:603–619. doi: 10.1016/S0167-6636(02)00288-0. [DOI] [Google Scholar]
- 12.Hoshikuma J., Kawashima K., Nagaya K., Taylor A.W. Stress-strain model for confined concrete in bridge piers. J. Struct. Eng. ASCE. 1997;123:624–633. doi: 10.1061/(ASCE)0733-9445(1997)123:5(624). [DOI] [Google Scholar]
- 13.Kent D.C., Park R. Flexural members with confined concrete. J. Struct. Div. ASCE. 1971;97:1969–1990. [Google Scholar]
- 14.Sheikh S.A. A Comparative study of confinement models. ACI J. 1982;79:296–305. [Google Scholar]
- 15.Mander J.B., Priestley M.J.N., Park R. Theoretical stress-strain model for confined concrete. J. Struct. Div. ASCE. 1988;114:1804–1826. doi: 10.1061/(ASCE)0733-9445(1988)114:8(1804). [DOI] [Google Scholar]
- 16.Mander J.B., Priestley M.J.N., Park R. Observed stress-strain behavior of confined concrete. J. Struct. Div. ASCE. 1988;114:1969–1990. doi: 10.1061/(ASCE)0733-9445(1988)114:8(1827). [DOI] [Google Scholar]
- 17.Saatcioglu M., Razvi S. Strength and ductility of confined concrete. J. Struct. Div. ASCE. 1992;118:1590–1607. doi: 10.1061/(ASCE)0733-9445(1992)118:6(1590). [DOI] [Google Scholar]
- 18.Mirmiran A., Shahawy M. Behavior of concrete columns confined by fiber composites. J. Struct. Div. ASCE. 1997;123:583–590. doi: 10.1061/(ASCE)0733-9445(1997)123:5(583). [DOI] [Google Scholar]
- 19.Harmon T.G., Ramakrishnan S., Wang E.H. Confined concrete subjected to uniaxial monotonic loading. J. Eng. Mech. ASCE. 1998;124:1303–1309. doi: 10.1061/(ASCE)0733-9399(1998)124:12(1303). [DOI] [Google Scholar]
- 20.Lin C.T., Li Y.F. An effective peak stress formula for concrete confined with carbon fiber reinforced plastics. Can. J. Civil Eng. 2003;30:882–889. doi: 10.1139/l03-047. [DOI] [Google Scholar]
- 21.Saeed H.Z., Khan Q.U.Z., Khan H.A., Farooq R. Experimental investigation of stress-strain behavior of CFRP confined low strength concrete (LSC) cylinders. Constr. Build. Mater. 2016;104:208–215. doi: 10.1016/j.conbuildmat.2015.12.061. [DOI] [Google Scholar]
- 22.Berthet J.F., Ferrier E., Hamelin P. Compressive behavior of concrete externally confined by composite jackets. Part A: Experimental study. Constr. Build. Mater. 2005;19:223–232. doi: 10.1016/j.conbuildmat.2004.05.012. [DOI] [Google Scholar]
- 23.Wootton I., Spainhour L., Yazdani N. Corrosion of steel reinforcement in carbon fiber-reinforced polymer wrapped concrete cylinders. J. Compos. Constr. 2003;7:339–347. doi: 10.1061/(ASCE)1090-0268(2003)7:4(339). [DOI] [Google Scholar]
- 24.Ceccatoa C., Teng J.G., Cusatis C. Numerical prediction of the ultimate condition of circular concrete columns confined with a fiber reinforced polymer jacket. Compos. Struct. 2020;241:112103. doi: 10.1016/j.compstruct.2020.112103. [DOI] [Google Scholar]
- 25.Cao Y., Liu M., Wu Y.F. Effect of low strain rate on the axial behavior of concrete in CFRP-confined circular cylinders. Constr. Build. Mater. 2020;255:119351. doi: 10.1016/j.conbuildmat.2020.119351. [DOI] [Google Scholar]
- 26.Han Q., Yuan W.Y., Ozbakkaloglu T., Bai Y.L., Du X.L. Compressive behavior for recycled aggregate concrete confined with recycled polyethylene naphthalate/terephthalate composites. Constr. Build. Mater. 2020;261:120498. doi: 10.1016/j.conbuildmat.2020.120498. [DOI] [Google Scholar]
- 27.Zhou J., Bi F., Wang Z., Zhang J. Experimental investigation of size effect on mechanical properties of carbon fiber reinforced polymer (CFRP) confined concrete circular specimens. Constr. Build. Mater. 2016;127:643–652. doi: 10.1016/j.conbuildmat.2016.10.039. [DOI] [Google Scholar]
- 28.Belouar A., Laraba A., Benzaid R., Chikh N. Structural performance of square concrete columns wrapped with CFRP sheets. Procedia Eng. 2013;54:232–240. doi: 10.1016/j.proeng.2013.03.021. [DOI] [Google Scholar]
- 29.Rousakis T.C. Inherent seismic resilience of RC columns externally confined with nonbonded composite ropes. Compos. Part B Eng. 2018;135:142–148. doi: 10.1016/j.compositesb.2017.10.023. [DOI] [Google Scholar]
- 30.Rousakis T.C., Panagiotakis G.D., EArchontaki E.E., Kostopoulos A. Prismatic RC columns externally confined with FRP sheets and pre-tensioned basalt fiber ropes under cyclic axial load. Compos. Part B Eng. 2019;136:96–106. doi: 10.1016/j.compositesb.2018.11.024. [DOI] [Google Scholar]
- 31.Micelli F., Modarelli R. Experimental and analytical study on properties affecting the behavior of FRP-confined concrete. Compos. Part B Eng. 2013;45:1420–1431. doi: 10.1016/j.compositesb.2012.09.055. [DOI] [Google Scholar]
- 32.Trapko T. The effect of high temperature on the performance of CFRP and FRCM confined concrete elements. Compos. Part B Eng. 2013;54:138–145. doi: 10.1016/j.compositesb.2013.05.016. [DOI] [Google Scholar]
- 33.Al-Salloum Y.A., Elsanadedy H.M., Abadel A.A. Behavior of FRP-confined concrete after high temperature exposure. Constr. Build. Mater. 2011;25:838–850. doi: 10.1016/j.conbuildmat.2010.06.103. [DOI] [Google Scholar]
- 34.da Costa Mattos H.S., Reis J.M.L., Paim L.M., da Silva M.L., Amorim F.C., Perrut V.A. Analysis of a glass fibre reinforced polyurethane composite repair system for corroded pipelines at elevated temperatures. Compos. Struct. 2014;114:117–123. doi: 10.1016/j.compstruct.2014.04.015. [DOI] [Google Scholar]
- 35.ASTM C39/C39M-18. Standard Test. Method for Compressive Strength of Cylindrical Concrete Specimens. ASTM; West Conshohocken, PA, USA: 2018. [Google Scholar]
- 36.ASTM International ASTM C109/C M109-02. Standard Test. Method for Compressive Strength of Hydraulic Cement Mortars. ASTM; West Conshohocken, PA, USA: 2016. [Google Scholar]
- 37.Jaeger J.G., Cook N.G.W., Zimmerman R.W. Fundamental of Rock Mechanics. 4th ed. Blackwell Publishing; Malden, MA, USA: 2007. pp. 91–92. [Google Scholar]
- 38.Li Y.F., Sio W.K., Tsai Y.K. A Compressive peak strength model for CFRP Confined Thermal Insulation Materials under elevated temperature. Materials. 2020;13:26. doi: 10.3390/ma13010026. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Nemat-Nasser S., Li Y.F., Isaacs J.B. Experimental/ computational evaluation of flow stress at high strain rates with application to adiabatic shear banding. Mech. Mater. 1994;17:23–56. doi: 10.1016/0167-6636(94)90053-1. [DOI] [Google Scholar]