Tale of two complications following phakic intraocular lens implantation: secondary glaucoma and central serous retinopathy in one eye and inverted phakic IOL with cataract in the other eye

Raghav Preetam Peraka 1, Somasheila I Murthy 1,, Subhakar Reddy 2, Raja Narayanan 2
PMCID: PMC7604822  PMID: 33127710

Description

A 25-year-old woman presented with a 6-month history of pain and decreased vision in both eyes. She had undergone bilateral phakic intraocular lens (IOL) implantation (implantable phakic contact lens (IPCL), V1.0, Care Group, Sight Solution, Vadodara, India) elsewhere 5 years earlier and was asymptomatic prior to this. For recurrent redness in the right eye (OD), she was started on topical and oral steroids and received two posterior subtenon injections of 20 mg/0.5 mL of triamcinolone acetonide 4 months ago for cystoid macular oedema. Subsequently, she was noted to have developed steroid-induced glaucoma and was on 1% brinzolamide/0.2% brimonidine eye drops twice a day. Visual acuity in OD was 20/30 (20/20 with glasses) and in left eye (OS) was 20/60, improving to 20/25. Anterior chambers were quiet and IPCL was well-positioned in OD (figure 1A, B). OS showed paracentral anterior subcapsular cataract (figure 1C, D). Intraocular pressures were normal. Gonioscopy showed bilateral dense trabecular pigments, open angles in OD and peripheral anterior synechiae with three-quadrant angle closure in OS.

Figure 1.

Figure 1

(A) Slit-lamp photograph of OD shows a well-positioned IPCL (central hole indicated by the white arrow). Some pigment is visible on the optic’s surface. (B) OD, dilated view. (C) Slit-lamp photograph of the left eye shows IPCL with anterior subcapsular cataract (arrow). (D) After pupillary dilatation, the IPCL is noted to be inverted with a zone of contact on the lens capsule (short arrow) and paracentral cataract (long arrow). IPCL, implantable phakic contact lens; OD, right eye.

Vertical cup-to-disc ratio was 0.7:1 in OD; visual fields showed incomplete biarcuate scotoma. Macula of OD showed blunted foveal reflex, dome-shaped elevation and multiple cystic spaces.

Anterior segment optical coherence tomography (AS-OCT) (Optovue, Fremont, California, USA) showed adequate vault in OD (figure 2A), and inverted IPCL, lens touch and localised cataract in OS (figure 2B). Macular OCT of OD revealed foveal neurosensory detachment, shaggy photoreceptors, pachyvessels and intraretinal schisis (figure 2C), and OS was normal (figure 2D). Specular microscopy showed counts of 2984 cells/mm2 in OD and 1442 cells/mm2 in OS. She was diagnosed with resolved uveitis with steroid-induced glaucoma in OD, and resolving central serous retinopathy (CSR) and inverted IPCL and cataract in OS. Timolol eye drops twice daily was added for OD, and oral steroids were tapered. She was advised to undergo explantation of IPCL and cataract surgery in OS but she did not undergo the procedure because she preferred to get it done locally in her town.

Figure 2.

Figure 2

(A) AS-OCT of the right eye shows adequate vault of 400 μm. (B) In the left eye, OCT shows obliterated vault and an inverted IPCL, which is in contact with the anterior lens capsule. Arrow points to the cataractous portion (C) Macular OCT of the right eye shows neurosensory detachment (arrow) at the fovea. (D) Macular scan of the left eye is normal. AS-OCT, anterior segment optical coherence tomography; IPCL, implantable phakic contact lens.

Phakic IOLs show excellent results in moderate-to-high myopia.1 IPCL demonstrated efficacy and safety similar to Visian implantable collamer lens.2 Complications, though rare, can be related to lens sizing. Large-sized lenses can cause high vault and iris chafing, leading to recurrent uveitis. Incorrect orientation while inserting the lens is a known complication. Inverted lens will cause a low vault and anterior polar cataract in a stellate pattern.3 Though rare, this was known to occur with the V1.0 version of IPCL due to incorrect loading technique, intraoperative flipping or failure to recognise the incorrect side after injection. The newer version, IPCL V2.0, has a special patterned hole on the leading left corner to ensure correct orientation and positioning of IPCL. AS-OCT is invaluable in identifying the vault and inversion of phakic IOLs, as in our case.4 Removal of an inverted lens is necessary to prevent further complications such as secondary glaucoma and cataract progression.5 Our patient had a series of unfortunate events in OD; she had chronic postoperative inflammation, perhaps due to IPCL position shift over time, leading to macular oedema and steroid-induced glaucoma, leading to steroid-induced CSR. These are additional confounding factors.

Learning points.

  • Inverted implantable phakic contact lens (IPCL) is an inadvertent and rare intraoperative complication and the surgeon should be familiar with the various tips for correct insertion

  • If a very low vault is noted postoperatively, the possibility of inverted lens should be considered, and examination should be repeated after dilating the pupil.

  • Anterior segment optical coherence tomography is a useful modality to measure the vault height and study the orientation of IPCL with respect to crystalline lens and to confirm inverted lens.

  • Inverted phakic intraocular lens eventually need to be explanted to avoid further complications such as secondary glaucoma, chronic uveitis and progressive cataracts.

Acknowledgments

Hyderabad Eye Research Foundation.

Footnotes

Contributors: RPP and SIM have conceptualised the work, drafted the manuscript and acquired the data. SIM has also treated the patient and revised the final manuscript. SR has acquired the data and analysed the same and contributed to the draft. RN has been involved in the management of the patient and review of the final draft.

Funding: The authors have not declared a specific grant for this research from any funding agency in the public, commercial or not-for-profit sectors.

Competing interests: None declared.

Patient consent for publication: Obtained.

Provenance and peer review: Not commissioned; externally peer-reviewed.

References

  • 1.Moya T, Javaloy J, Montés-Micó R, et al. . Implantable collamer lens for myopia: assessment 12 years after implantation. J Refract Surg 2015;31:548–56. 10.3928/1081597X-20150727-05 [DOI] [PubMed] [Google Scholar]
  • 2.Sachdev GS, Singh S, Ramamurthy S, et al. . Comparative analysis of clinical outcomes between two types of posterior chamber phakic intraocular lenses for correction of myopia and myopic astigmatism. Indian J Ophthalmol 2019;67:1061. 10.4103/ijo.IJO_1501_18 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Gonvers M, Othenin-Girard P, Bornet C, et al. . Implantable contact lens for moderate to high myopia: short-term follow-up of 2 models. J Cataract Refract Surg 2001;27:380–8. 10.1016/s0886-3350(00)00759-8 [DOI] [PubMed] [Google Scholar]
  • 4.Alfonso JF, Fernández-Vega-Cueto L, Alfonso-Bartolozzi B, et al. . Five-Year follow-up of correction of myopia: posterior chamber phakic intraocular lens with a central Port design. J Refract Surg 2019;35:169–76. 10.3928/1081597X-20190118-01 [DOI] [PubMed] [Google Scholar]
  • 5.Sanders DR, ICL in Treatment of Myopia Study Group . Postoperative inflammation after implantation of the implantable contact lens. Ophthalmology 2003;110:2335–41. 10.1016/S0161-6420(03)00826-1 [DOI] [PubMed] [Google Scholar]

Articles from BMJ Case Reports are provided here courtesy of BMJ Publishing Group

RESOURCES