Abstract
Background
Retinal ganglion cell (RGC) loss is crucial in eye diseases like glaucoma. Axon damage and dendritic degeneration precede cell death, detectable within optical coherence tomography (OCT) resolution, indicating their correlation with neuronal degeneration. The purpose of this study is to evaluate the optical changes of early retinal degeneration.
Methods
The detection of optical changes in the axotomised retinal explants was completed in six C57BL/6J mice. OCT images were acquired up to 120 min from enucleation. A grey-level co-occurrence-based texture analysis was performed on the inner plexiform layer (IPL) to monitor changes in the optical speckles using a principal component analysis (PCA) and a support vector machine (SVM). In parallel tests, retinal transparency was confirmed by a comparison of the modulation transfer functions (MTFs) at 0 and 120 min.
Results
Quantitative confirmation by analysis of the MTFs confirmed the non-degradation of optical transparency during the imaging period: MTF (fx) = 0.267 ± 0.02. Textural features in the IPL could discriminate between the optical signals of RGC degeneration. The mean accuracy of the SVM classification was 86.3%; discrimination was not enhanced by the combination of the SVM and PCA (81.9%).
Conclusions
Optical changes in the IPL can be detected using OCT following RGC axotomy. High-resolution OCT can provide an index of retinal neuronal integrity and its degeneration.
Keywords: modulation transfer function, optical coherence tomography, retinal ganglion cell, support vector machine, principal component analysis
1. Introduction
Retinal ganglion cell (RGC) loss is a signature pathological event in many eye diseases and remains a topic of intense study [1–4]. Axon damage is a common driver of these changes in conditions such as glaucoma and traumatic optic neuropathy in which a compromised axonal transport initiates the disruption of organelles such as mitochondria [5,6] as a prelude to the initiation of programmed cell death. This sequence of neuronal degeneration provides a useful temporal window for detecting RGC dysfunction before the onset of cell death.
Dendritic degeneration has emerged as a robust marker of RGC degeneration [7]. Dendrite pruning can be driven extracellularly by the activation of the complement cascade pathway [8] and intracellularly through caspase activation [9–11]. Common to both is the fragmentation of the mitochondrial network, a characteristic feature of pre-apoptotic damage that can be seen histologically as beading in RGC dendrites [12,13]. Critically, these structural changes (within the range of 1–5 µm) lie within the detection resolution of high-resolution optical coherence tomography (OCT) [14,15]. While this does not imply the optical resolution of subcellular structures, it suggests that these changes generate optical signals that correlate with neuronal degeneration [16]. The feasibility of this approach is helped by the concentration of RGC dendrites within the inner plexiform layer (IPL), which represents a practical region of interest (ROI) for the assessment of RGC degeneration (or its inverse, neuronal health). Furthermore, the higher refractive index of membranous organelles such as mitochondria (1.48) [17,18] relative to the whole cell (1.38) [19] suggests that they contribute significantly to light scattering within the IPL [20].
We have previously reported that changes in optical texture correlate with the time course of degeneration in RGC5 cells [21]. A potential confounder of this analysis is that culture-related optical transparency reductions could generate spurious degeneration signals. We aim to develop optic tools for characterising retinal neuronal degeneration, specifically focusing on the tissues that remain transparent and healthy under clinical observation. To achieve this, we evaluated these changes in a retinal explant model. Additionally, we assessed retinal transparency by measuring the modulation transfer function during an imaging interval conducive to detecting early retinal degeneration.
2. Materials and Methods
2.1. Tissue Preparation
All experiments were conducted in accordance with Home Office regulations and the ARVO Statement for the Use of Animals in Ophthalmic and Vision Research. C57BL/6J mice (minimum age of 15 months) were sacrificed by cervical dislocation (Schedule 1 Appropriate Methods of Humane Killing, United Kingdom Animal Scientific Procedures Act 1986). The number of animals used in this study is in line with the UK NC3Rs policy regarding the use of animals in research.
Following enucleation, the eyes were further dissected in Hank’s balanced salt solution (HBSS, Life Technologies). The globe was penetrated at the limbus to remove the intraocular fluid, lens, and vitreous humour and to separate the retina. The retina was immediately transferred to a Petri dish and flat-mounted (ganglion cell layer up). The flat-mounted retinas were then imaged using a custom-built OCT (Figure 1), the technical details of which are described elsewhere [22]. During the post-dissection and imaging periods, the tissues were kept in a B27/Neurobasal (NB) medium (Thermo Fisher, Loughborough, UK) at room temperature. All explants were subject to the same laboratory conditions and were divided into two groups: one group for the assessment of optical transparency and the other for an OCT analysis; as it was performed in a 2 h time window, it was not technically possible to quantify both the retinal transparency and optical texture of the same sample.
Figure 1.
Mouse retinal explant preparation: after dissection and sectioning of the optic nerve, retinal tissue is flat-mounted in the coverslip and imaged using the Olympus-IX71 microscope (for the evaluation of transparency/opacity of retinal explants after axotomy) and OCT microscopy (for the monitoring of early RGC dendritic degeneration after axotomy). This was created with BioRender.comc.
2.2. Retinal Transparency Post Axotomy: Analysis of the Modulation Transfer Function
Explants were imaged using an Olympus-IX71 microscope to measure the modulation transfer function (MTF), computed as the normalised modulus of the fast Fourier transform (FFT) of the point spread function (PSF) [23]. The summation of the line of overlapping PSFs forms the line spread function (LSF) (Equation (1)), and we would expect the PSF width to increase if the optical transparency of the retina were compromised.
| (1) |
The LSF is the first derivative of the edge spread function (ESF), the image profile of an edge [24]; the ESF is built from a set of parallel LSFs, which end at the edge position. The modulation depth of a target placed under the retina and the transfer ratios were calculated (Equation (2)) and (Equation (3)) using the pixel intensity ranges from digital images (1360 × 1024 pixels). The MTF is defined as the ratio of the image’s contrast with the tissue to the contrast of the micrograph of the calibration slide.
| (2) |
where MI(fx) and MO(fx) are the modulation depths of the images of the grid lines with and without the retinal explant, respectively. Equation (2) can be expanded as Equation (3).
| (3) |
where Imax−I and Imin−I are the maximum and minimum intensity of the image with the retinal explant (I—image); Imax−O and Imin−O are the maximum and minimum intensity of the image without the retinal explant (O—object).
In order to measure the maximum and minimum intensity of the image with a retinal explant, the explanted retinal samples were placed on a Petri dish with the stage micrometre calibration slide (Muhwa Scientific, Shanghai, China) comprising a 1 mm scale of high contrast black and white lines, marking 0.01 mm divisions. At baseline, a control greyscale image was taken of the calibration slide (with an overlying Petri dish and without an overlying retinal explant) to measure the Imax−O and Imin−O.
Microscope images of the calibration graticule with and without the intervening retinal explant are shown in Figure 2. The Imax of both the images with and without the retinal tissue is 255, whereas their Imin differs: it is 57 for the image without an explant and 138 for the image with an explant.
Figure 2. Schematic diagram of the microscopy imaging (left) and acquired micrographs (right).
The control image was acquired without the explant (a); the retinal tissue was placed on a Petri dish with an underlying calibration slide for the measurement of MTF in dynamics (b).
2.3. Retinal Atrophy Post Axotomy: Texture Analysis of RGC Dendritic Tree
The dispersion compensation of the OCT images was performed during the image acquisition process, and all images were inspected as part of quality assurance before image processing. The analysis was conducted on a separate retinal series from those used for MTF analysis. The spectral data generated by OCT microscopy were processed into TIFF files with custom-built file conversion software (VSBL, Cardiff University, Cardiff, UK). An FFT filter was used to remove line-scan artefacts and background noise using FIJI Image J (NIH). The volumes of interest (VOI) and the textural features were then selected as previously reported [25].
OCTs were taken of 3 C57BL/6J mice explants (2 images from each retina) and were performed following insertion into the culture plate at the time points 0, 30, 60, and 120 min to provide 24 images. A total of 10 volumes of interest (VOI) were then manually selected within the IPL to provide 20 VOI for each retina, and 240 VOI in total for all the time points. Each VOI comprised 30 × 30 × 30 pixels (x, y and z): x and z coordinates were selected by a random number generator, and the y coordinate was chosen from the IPL/ganglion cell layer border along with the IPL thickness.
Five grey-level co-occurrence matrix (GLCM) features in four directions (0°, 90°, 180°, and 270°) were extracted from each VOI using the FIJI plug-in “GLCM Texture” [26,27]. GLCM features (n = 20) (energy, contrast, entropy, correlation, and homogeneity) were extracted for four spatial directions. The 20-dimensional feature space was then analysed using machine learning (ML) tools—a principal component analysis (PCA) and support vector machine (SVM) [28].
The first and second principal components in the 2-dimensional data set, including 95% of the variance, were chosen for the PCA. The motivation for using a PCA was the dimension reduction and cost-effectiveness of the algorithm [29,30]. Among the SVM algorithms, a linear kernel was used for its higher accuracy in our previous study, where a retinal subcellular, constituent-mimicking phantom classification was made [25]. ML-based optical sign detection analysis was performed in Simulink using MATLAB R2019b (MathWorks).
3. Results
In total, six retinal explants were used in this study, all maintained under identical laboratory conditions. Three explants were used to quantify the changes in optical transparency, and three for the OCT measurements of optic texture. Technically, acquiring the explant OCT image and MTF data in the same tissue was impossible. After each experiment, all explants (six) were optically clear under microscopic inspection.
3.1. Transparency of the Retinal Explants
Figure 3A shows the micrographs of the calibration slide with the tissue explants at different time points. The images were timed following the capture of the first image of the retina in the culture (time 0) and at 30, 60, and 120 min thereafter. The preparation time for each retinal explant was 2–3 min (±1.5 min), so that time 0 represented 3–4 min post-mortem. The corresponding OCT images of the murine retinal explants were acquired (Figure 3B) at the same time intervals: at 0, 30, 60, and 120 min. The samples were moved from the OCT microscope platform to replace the Petri dish lid between OCT image acquisitions, so as to prevent an exact alignment of the regions of interest due to movement in the NB medium. Since the explants were covered with the NB medium, an air–fluid interface was not discernible in the OCT images.
Figure 3.
Microscopy (A) and OCT (B) images of the calibration slide with the tissue explants at different time points. The images were taken within the volumes of interest (VOI) of 30 × 30 × 30 pixels (x, y, and z). Scale bar for OCT images (B) = 50 µm.
The mean, maximum, and minimum intensity values of the time series micrographs were measured. Using Equations (1) and (2), the modulation features were calculated and the MTF(f x) ratios are provided in Figure 3A.
The ESF, LSF, and MTF relationships and the results of the computations are shown in Figure 4A–C. The x-axis of the MTF plot is the normalized modulation factor against the frequency input (cycles/pixel). The spread and modulation transfer function values remained stable, and an opacification of the retinal explants was not observed within the 2 h of imaging, confirming the preservation of optical transparency.
Figure 4.
(A) Edge spread function, (B) line spread function, and (C) modulation transfer function for explant microscopy images with and without the retinal explants. All functions were unchanged and there were no signs of secondary opacification of tissues during the 2 h of post-dissection. (D) 3D rendered OCT image of a mouse retinal explant at time 0 (see Figure 3B), RGC side up. Abbreviations: RNFL—retinal nerve fibre layer; GCL—ganglion cell layer; IPL—inner plexiform layer; INL—inner nuclear layer; OPL—outer plexiform layer; ONL—outer nuclear layer; PR—photoreceptor layer; ELM—external limiting membrane; IS/OS—the junction between the photoreceptor outer and inner segments; and RPE—retinal pigment epithelium.
3.2. IPL Texture Analysis Post Axotomy
The layers of the murine retina were discernible throughout the experiment (Figure 4D), which allowed for the selection of VOI from the IPL and the avoidance of areas within the blood vessels. Along with the other features of the grey-level dependency matrix, during the feature selection process, the entropy and contrast in ϑ = 0° between the reference (j-th) and index (i-th) pixels provided the most benefit to the performance of the SVM classifier (Figure 5): the clusters of early (0 and 30 min) and late (60 and 120 min) stages of post axotomy were separable in the feature space. The data from all the VOI of all the retinal explants were imported into the ML classifier.
Figure 5. Texture analysis of post-axotomy retinal explants at the following time points: time 0, 30 min, 60 min, and 120 min.
Four clusters in the feature space: the two most discriminating grey-level co-occurrence matrix features—contrast and entropy—demonstrated a better classification performance.
After the transection of the optic nerve, the cluster representing the images at 30 min shifted slightly right and to the top of the feature space above. In contrast, at 60 and 120 min, the clusters in the 2D feature space shifted more in the same direction from the baseline time 0 position, and the border between the early and late stages of axotomy was visible. We noted a considerable overlap at 0 and 30 min (no discrimination), but clear separation at 0 and 60 min can be seen in the 2-dimensional feature space (Figure 5) and in Table 1.
Table 1. Machine learning-based classification summary.
| SVM Classification | |||||||
|---|---|---|---|---|---|---|---|
| Predicted Class (% Correct) | TPR | FPR | |||||
| Time Points | Time 0 | 30 min | 60 min | 120 min | |||
| True Class | time 0 | 75% | 25% | 0% | 0% | 75% | 25% |
| 30 min | 23% | 77% | 0% | 0% | 77% | 23% | |
| 60 min | 0% | 0% | 97% | 3% | 97% | 3% | |
| 120 min | 0% | 0% | 4% | 96% | 96% | 4% | |
| PCA and SVM Classification | |||||||
| Predicted Class (% Correct) | TPR | FPR | |||||
| Time Points | Time 0 | 30 min | 60 min | 120 min | |||
| True Class | time 0 | 70% | 30% | 0% | 0% | 70% | 30% |
| 30 min | 28% | 72% | 0% | 0% | 72% | 28% | |
| 60 min | 0% | 0% | 92% | 8% | 92% | 8% | |
| 120 min | 0% | 0% | 7% | 93% | 93% | 7% | |
Abbreviations: TPR—true positive rate; FPR—false positive rate.
The rate of misclassification was greatest for the samples at 0 and 30 min: 24 ± 1% of the false negative rate with the SVM only and 29 ± 1% with the PCA + SVM. By contrast, the time images taken at 60 and 120 min could be classified with a high degree of accuracy (92.5 ± 0.5%). In summary, we can discriminate between time 0 and 60 min, and 30 min and 60 min, but not between time 0 and 30 min or 60 min and 120 min.
4. Discussion
The MTF analysis confirmed that retinal explants, in an NB medium under room air temperature maintained optical transparency 2 h after optic nerve transection during which time we could detect the changes in optical texture using OCT microscopy.
Previous work suggests that organelle fragmentation particularly among mitochondria [21] is a source of change in optical texture/contrast. However, given the numerous candidate sources of a change in retinal light backscatter [31–33], the precise identification of these scatterers lies outside the scope of this study. A recent analysis of retinal phantoms containing scattering agents with refractive indices that mimic the optical properties of organelles such as mitochondria indicates that they generate variation in optical texture that can be used to discriminate scattering agents [25].
The shift of the cluster in the later stages of apoptosis (60 and 120 min) in the 2-dimensional space (from 20D after a PCA dimensionality reduction) demonstrates a change in the optical signature aligned with the period of RGC degeneration. Similar apoptotic changes, initiated by the administration of staurosporine [34,35] were investigated in an RGC-5 cell culture for the in vitro detection of early apoptosis using an ultrahigh-resolution OCT [21,36].
The axial resolution of OCT is determined by the wavelength of the coherent light [37–40] and the full width at half maximum (FWHM) of the light source [41–44]. It is important to note that a useful time point classification could be achieved even though our device’s longitudinal and transverse resolutions are not matched (non-isotropic) [45], with the central λ = 1040 nm and FWHM = 70 nm. It is reasonable to conclude that a higher FWHM (consequently with a higher axial resolution) would further enhance the accuracy of texture-based discrimination.
5. Conclusions
Detecting apoptosis, particularly in its early stages, remains a topic of considerable interest and clinical relevance. The present studies further support using ligand-free methods for quantifying retinal health [13,25]. Although the present study is restricted to the retinal ganglion cell layer where axotomy can be used as a precise temporal driver of neuronal degeneration, the explant model is suited to studying the optical scattering associated with the degeneration of the outer retinal layers.
Acknowledgments
M.K. was supported by the InnoHK initiative and the Hong Kong Special Administrative Region Government.
Funding
This research was funded by the Vice-Chancellor’s International Scholarships for Research Excellence, Cardiff University, Cardiff, UK (M.K.), the Medical Research Council (G0800547, JEM), Tweedie Bequest, University Hospital of Wales (J.M.), and the NIH’s National Institute of General Medical Sciences (1R01GM143388-01A1), (A.A.).
Footnotes
Author Contributions: Conceptualization, M.K. and J.M.; methodology, J.M., N.A. and M.K.; software, N.A. and M.K; validation, A.A., N.A. and J.M.; formal analysis, M.K.; investigation, R.B., A.W. and M.K.; resources, J.A. and J.M.; data curation, J.A. and N.A.; writing—original draft preparation, M.K.; writing—review and editing, A.A., J.A. and J.M.; visualization, M.K.; supervision, J.M. and J.A.; project administration, J.A. and J.M.; funding acquisition, J.M. All authors have read and agreed to the published version of the manuscript.
Conflicts of Interest: The authors declare no conflicts of interest.
Institutional Review Board Statement: The animal study protocol was under the UK Animals Scientific Procedures Act 1986 and the ethical guidelines of Cardiff University under the authority of UK Home Office licences (30/3220, P8159A562 and 30/03313).
Informed Consent Statement: Not applicable.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
Contributor Information
Ryan Bevan, Email: bevanrj@cardiff.ac.uk.
Andrew Want, Email: wanta@cardiff.ac.uk.
Nantheera Anantrasirichai, Email: n.anantrasirichai@bristol.ac.uk.
Alin Achim, Email: eeama@bristol.ac.uk.
Julie Albon, Email: albonj@cardiff.ac.uk.
James Morgan, Email: morganje3@cardiff.ac.uk.
Abbreviations
The following abbreviations are used in this manuscript:
- ELM
External limiting membrane
- ESF
Edge spread function
- FFT
Fourier transform
- FPR
False positive rate
- FWHM
Full width at half maximum
- GCL
Ganglion cell layer
- GLCM
Grey-level co-occurrence matrix
- HBSS
Hank’s balanced salt solution
- INL
Inner nuclear layer
- IPL
Inner plexiform layer
- IS/OS
Junction between the photoreceptor outer and inner segments
- LSF
Line spread function
- ML
Machine learning
- MTF
Modulation transfer function
- NB
Neurobasal
- OCT
Optical coherence tomography
- ONL
Outer nuclear layer
- OPL
Outer plexiform layer
- PCA
Principal component analysis
- PR
Photoreceptor
- PSF
Point spread function
- RGC
Retinal ganglion cell
- RNFL
Retinal nerve fibre layer
- ROI
Region of interest
- RPE
Retinal pigment epithelium
- SVM
Support vector machine
- TPR
True positive rate
Data Availability Statement
Information on the data underpinning this publication, including access details, can be found in the Figshare Research Data Repository at https://doi.org/10.6084/m9.figshare.28451531.
References
- 1.Almasieh M, Wilson AM, Morquette B, Cueva Vargas JL, Di Polo A. The molecular basis of retinal ganglion cell death in glaucoma. Prog Retin Eye Res. 2012;31:152–181. doi: 10.1016/j.preteyeres.2011.11.002. [DOI] [PubMed] [Google Scholar]
- 2.Smith C, Vianna J, Chauhan B. Assessing retinal ganglion cell damage. Eye. 2017;31:209–217. doi: 10.1038/eye.2016.295. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Khatib T, Martin K. Protecting retinal ganglion cells. Eye. 2017;31:218–224. doi: 10.1038/eye.2016.299. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Vernazza S, Oddone F, Tirendi S, Bassi AM. Risk Factors for Retinal Ganglion Cell Distress in Glaucoma and Neuroprotective Potential Intervention. Int J Mol Sci. 2021;22:7994. doi: 10.3390/ijms22157994. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.DePina AS, Langford GM. Vesicle transport: The role of actin filaments and myosin motors. Microsc Res Tech. 1991;47:93–106. doi: 10.1002/(SICI)1097-0029(19991015)47:2<93::AID-JEMT2>3.0.CO;2-P. [DOI] [PubMed] [Google Scholar]
- 6.Munemasa Y, Kitaoka Y. Molecular mechanisms of retinal ganglion cell degeneration in glaucoma and future prospects for cell body and axonal protection. Front Cell Neurosci. 2013;6:60. doi: 10.3389/fncel.2012.00060. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Williams PA, Tribble JR, Pepper KW, Cross SD, Morgan BP, Morgan JE, John SWM, Howell GR. Inhibition of the classical pathway of the complement cascade prevents early dendritic and synaptic degeneration in glaucoma. Mol Neurodegener. 2016;11:26. doi: 10.1186/s13024-016-0091-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Williams PA, Howell GR, Barbay JM, Braine CE, Sousa GL, John SWM, Morgan JE. Retinal Ganglion Cell Dendritic Atrophy in DBA/2J Glaucoma. PLoS ONE. 2013;8:e72282. doi: 10.1371/journal.pone.0072282. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Fan T-J, Han L-H, Cong R-S, Liang J. Caspase Family Proteases and Apoptosis. Acta Biochim Biophys Sin. 2005;37:719–727. doi: 10.1111/j.1745-7270.2005.00108.x. [DOI] [PubMed] [Google Scholar]
- 10.Kumar S. Caspase function in programmed cell death. Cell Death Differ. 2006;14:32. doi: 10.1038/sj.cdd.4402060. [DOI] [PubMed] [Google Scholar]
- 11.Hoshino A, Ratnapriya R, Brooks MJ, Chaitankar V, Wilken MS, Zhang C, Starostik MR, Gieser L, Torre La, Nishio M, et al. Molecular Anatomy of the Developing Human Retina. Dev Cell. 2017;43:763–779. doi: 10.1016/j.devcel.2017.10.029. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Tribble JR, Vasalauskaite A, Redmond T, Young RD, Hassan S, Fautsch MP, Sengpiel F, Williams PA, Morgan JE. Midget retinal ganglion cell dendritic and mitochondrial degeneration is an early feature of human glaucoma. Brain Commun. 2019;1:fcz035. doi: 10.1093/braincomms/fcz035. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.You W, Knoops K, Boesten I, Berendschot TTJM, van Zandvoort MAMJ, Benedikter BJ, Webers CAB, Reutelingsperger CPM, Gorgels TGMF. A time window for rescuing dying retinal ganglion cells. Cell Commun Signal. 2024;22:88. doi: 10.1186/s12964-023-01427-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Reche J, Stocker AB, Henchoz V, Habra O, Escher P, Wolf S, Zinkernagel MS. High-Resolution Optical Coherence Tomography in Healthy Individuals Provides Resolution at the Cellular and Subcellular Levels. Transl Vis Sci Technol. 2023;12:12. doi: 10.1167/tvst.12.7.12. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Hamza A, Hayward TM, Majumder A, Brimhall N, Menon R, Ha I. High-resolution optical coherence tomography using a multi-level diffractive lens. Opt Express. 2024;32:27748–27755. doi: 10.1364/OE.529870. [DOI] [PubMed] [Google Scholar]
- 16.Erchova I, Tumlinson AR, Fergusson J, White N, Drexler W, Sengpiel F, Morgan JE. Optophysiological Characterisation of Inner Retina Responses with High-Resolution Optical Coherence Tomography. Sci Rep. 2018;8:1813. doi: 10.1038/s41598-018-19975-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Wilson JD, Cottrell WJ, Foster TH. Index-of-refraction-dependent subcellular light scattering observed with organelle-specific dyes. J Biomed Opt. 2007;12:014010. doi: 10.1117/1.2437765. [DOI] [PubMed] [Google Scholar]
- 18.Mourant JR, Canpolat M, Brocker C, Esponda-Ramos O, Johnson TM, Matanock A, Stetter K, Freyer JP. Light scattering from cells: The contribution of the nucleus and the effects of proliferative status. J Biomed Opt. 2000;5:131–137. doi: 10.1117/1.429979. [DOI] [PubMed] [Google Scholar]
- 19.Beuthan J, Minet O, Helfmann J, Herrig M, Müller G. The spatial variation of the refractive index in biological cells. Phys Med Biol. 1996;41:369–382. doi: 10.1088/0031-9155/41/3/002. [DOI] [PubMed] [Google Scholar]
- 20.Gourley PL, Hendricks JK, McDonald AE, Copeland RG, Barrett KE, Gourley CR, Singh KK, Naviaux RK. Mitochondrial Correlation Microscopy and Nanolaser Spectroscopy—New Tools for Biophotonic Detection of Cancer in Single Cells. Technol Cancer Res Treat. 2005;4:585–592. doi: 10.1177/153303460500400602. [DOI] [PubMed] [Google Scholar]
- 21.Tudor D, Kajić V, Rey S, Erchova I, Považay B, Hofer B, Powell KA, Marshall D, Rosin PL, Drexler W, et al. Non-Invasive Detection of Early Retinal Neuronal Degeneration by Ultrahigh Resolution Optical Coherence Tomography. PLoS ONE. 2014;9:e93916. doi: 10.1371/journal.pone.0093916. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Kulmaganbetov M, Morgan JE. Handbook of Texture Analysis. CRC Press; Boca Raton, FL, USA: 2024. Application of Texture Analysis in Retinal OCT Imaging; pp. 154–179. [Google Scholar]
- 23.Williams CS, Becklund OA. Introduction to the Optical Transfer Function. SPIE Press; Bellingham, WA, USA: 2002. pp. 23–64. [Google Scholar]
- 24.Boreman GD. Modulation Transfer Function in Optical and Electro-Optical Systems. SPIE Press; Bellingham, WA, USA: 2001. pp. 1–50. [Google Scholar]
- 25.Kulmaganbetov M, Bevan RJ, Anantrasirichai N, Achim A, Erchova I, White N, Albon J, Morgan JE. Textural Feature Analysis of Optical Coherence Tomography Phantoms. Electronics. 2022;11:669. doi: 10.3390/electronics11040669. [DOI] [Google Scholar]
- 26.Haralick RM, Shanmugam K, Dinstein I. Textural Features for Image Classification. IEEE Trans Syst Man Cybern. 1973;3:610–621. doi: 10.1109/TSMC.1973.4309314. [DOI] [Google Scholar]
- 27.Conners RW, Trivedi MM, Harlow CA. Segmentation of a high-resolution urban scene using texture operators. Comput Vis Graph Image Process. 1984;25:273–310. doi: 10.1016/0734-189X(84)90197-X. [DOI] [Google Scholar]
- 28.Anantrasirichai N, Achim A, Morgan JE, Erchova I, Nicholson L. SVM-based texture classification in Optical Coherence Tomography; Proceedings of the 2013 IEEE 10th International Symposium on Biomedical Imaging; San Francisco, CA, USA. 2013. Apr 7–11, [Google Scholar]
- 29.Jolliffe IT, Cadima J. Principal component analysis: A review and recent developments. Philos Trans A Math Phys Eng Sci. 2016;374:20150202. doi: 10.1098/rsta.2015.0202. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Koch I, Naito K. Dimension selection for feature selection and dimension reduction with principal and independent component analysis. Neur Comput. 2007;19:513–545. doi: 10.1162/neco.2007.19.2.513. [DOI] [PubMed] [Google Scholar]
- 31.Litts KM, Zhang Y, Freund KB, Curcio CA. Optical coherence tomography and histology of age-related macular degeneration support mitochondria as reflectivity sources. Retina. 2018;38:445–461. doi: 10.1097/IAE.0000000000001946. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Scholler J, Groux K, Goureau O, Sahel JA, Fink M, Reichman S, Boccara C, Grieve K. Dynamic full-field optical coherence tomography: 3D live-imaging of retinal organoids. Light Sci Appl. 2020;9:140. doi: 10.1038/s41377-020-00375-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Chauhan P, Kho AM, FitzGerald P, Shibata B, Srinivasan VJ. Subcellular Comparison of Visible-Light Optical Coherence Tomography and Electron Microscopy in the Mouse Outer Retina. Invest Ophthalmol Vis Sci. 2022;63:10. doi: 10.1167/iovs.63.9.10. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Schultheiss M, Schnichels S, Miteva K, Warstat K, Szurman P, Spitzer MS, Van Linthout S. Staurosporine-induced differentiation of the RGC-5 cell line leads to apoptosis and cell death at the lowest differentiating concentration. Graefes Arch Clin Exp Ophthalmol. 2012;250:1221–1229. doi: 10.1007/s00417-011-1906-3. [DOI] [PubMed] [Google Scholar]
- 35.Gil J, Almeida S, Oliveira CR, Rego AC. Cytosolic and mitochondrial ROS in staurosporine-induced retinal cell apoptosis. Free Radic Biol Med. 2003;35:1500–1514. doi: 10.1016/j.freeradbiomed.2003.08.022. [DOI] [PubMed] [Google Scholar]
- 36.Cordeiro MF, Guo L, Luong V, Harding G, Wang W, Jones HE, Moss SE, Sillito AM, Fitzke FW. Real-time imaging of single nerve cell apoptosis in retinal neurodegeneration. Proc Natl Acad Sci USA. 2004;101:13352–13356. doi: 10.1073/pnas.0405479101. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Israelsen NM, Petersen CR, Barh A, Jain D, Jensen M, Hannesschläger G, Tidemand-Lichtenberg P, Pedersen C, Podoleanu A, Bang O. Real-time high-resolution mid-infrared optical coherence tomography. Light Sci Appl. 2019;8:11. doi: 10.1038/s41377-019-0122-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Nishizawa N, Kawagoe H, Yamanaka M, Matsushima M, Mori K, Kawabe T. Wavelength Dependence of Ultrahigh-Resolution Optical Coherence Tomography Using Supercontinuum for Biomedical Imaging. IEEE J Sel Top Quantum Electron. 2019;25:1–15. doi: 10.1109/JSTQE.2018.2854595. [DOI] [Google Scholar]
- 39.Wachulak P, Bartnik A, Fiedorowicz H. Optical coherence tomography (OCT) with 2 nm axial resolution using a compact laser plasma soft X-ray source. Sci Rep. 2018;8:8494. doi: 10.1038/s41598-018-26909-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Lee SW, Jeong HW, Kim BM, Ahn YC, Jung W, Chen Z. Optimization for Axial Resolution, Depth Range, and Sensitivity of Spectral Domain Optical Coherence Tomography at 1.3 µm. J Korean Phys Soc. 2009;55:2354–2360. doi: 10.3938/jkps.55.2354. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Lee B, Chen S, Moult EM, Yu Y, Alibhai AY, Mehta N, Baumal CR, Waheed NK, Fujimoto JG. High-Speed, Ultrahigh-Resolution Spectral-Domain OCT with Extended Imaging Range Using Reference Arm Length Matching. Trans Vis Sci Tech. 2020;9:12. doi: 10.1167/tvst.9.7.12. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42.Sato M, Wakaki I, Watanabe Y, Tanno N. Fundamental characteristics of a synthesized light source for optical coherence tomography. Appl Opt. 2005;44:2471–2481. doi: 10.1364/ao.44.002471. [DOI] [PubMed] [Google Scholar]
- 43.Bousi E, Charalambous I, Pitris C. Optical coherence tomography axial resolution improvement by step-frequency encoding. Opt Express. 2010;18:11877–11890. doi: 10.1364/OE.18.011877. [DOI] [PubMed] [Google Scholar]
- 44.Makita S, Fabritius T, Yasuno Y. Full-range, high-speed, high-resolution 1-µm spectral-domain optical coherence tomography using BM-scan for volumetric imaging of the human posterior eye. Opt Express. 2008;16:8406–8420. doi: 10.1364/oe.16.008406. [DOI] [PubMed] [Google Scholar]
- 45.Tsai CY, Shih CH, Chu HS, Hsieh YT, Huang SL, Chen WL. Submicron spatial resolution optical coherence tomography for visualising the 3D structures of cells cultivated in complex culture systems. Sci Rep. 2021;11:3492. doi: 10.1038/s41598-021-82178-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
Information on the data underpinning this publication, including access details, can be found in the Figshare Research Data Repository at https://doi.org/10.6084/m9.figshare.28451531.





