. 2020 Nov 5;20(21):6293. doi: 10.3390/s20216293

Accuracy of Mobile Applications versus Wearable Devices in Long-Term Step Measurements

Filippo Piccinini 1,*, Giovanni Martinelli 1, Antonella Carbonaro 2
PMCID: PMC7663794  PMID: 33167361

Abstract

Fitness sensors and health systems are paving the way toward improving the quality of medical care by exploiting the benefits of new technology. For example, the great amount of patient-generated health data available today gives new opportunities to measure life parameters in real time and create a revolution in communication for professionals and patients. In this work, we concentrated on the basic parameter typically measured by fitness applications and devices—the number of steps taken daily. In particular, the main goal of this study was to compare the accuracy and precision of smartphone applications versus those of wearable devices to give users an idea about what can be expected regarding the relative difference in measurements achieved using different system typologies. In particular, the data obtained showed a difference of approximately 30%, proving that smartphone applications provide inaccurate measurements in long-term analysis, while wearable devices are precise and accurate. Accordingly, we challenge the reliability of previous studies reporting data collected with phone-based applications, and besides discussing the current limitations, we support the use of wearable devices for mHealth.

Keywords: health and fitness datasets, step measurements, fitness trackers, wearable devices, mobile applications, long-term analysis

1. Introduction

Innovative applications (apps) and smart devices such as smartphones and tablets have emerged as integral parts of people’s lives [1]. They provide information to profile society [2], but also to make users aware of body signals important for predicting life expectancy [3], promoting patient engagement, self-management of diseases, and assist doctors to remotely follow up patients [4]. In particular, in the healthcare sector, we have seen the development of systems to assist users in different ways during the day [5] and night [6]. These devices offer incredible potential to generate big data, often identified as patient-generated health data (PGHD), that could influence medical doctors’ decision-making [7], as well as the potential for earlier diagnosis [8]. The World Health Organization (WHO) defines these tools under the labels electronic health (eHealth) and mobile health (mHealth): eHealth refers to any use of information and communication technology for health care; mHealth is a subset of eHealth specifically referring to the use of mobile and wireless devices. For instance, fitness trackers, blood glucose meters [9], blood pressure monitors [10], smoking sensors [11], and temperature-detection devices [12] are today popular for monitoring different fitness parameters and vital signs used for health analysis [13] and many other motion-related applications including tracking, positioning, activity recognition, and augmented reality [14]. In addition, electronic textiles (e-textiles), smart clothes, and flexible/printable electronics bring us closer to scenarios where electronic systems are totally integrated in our everyday life and help us in achieving a higher comfort level when interacting with smartphones and domotics in general [15].

Actually, there are three main ways to monitor and record physical activity (PA) parameters: (a) subjective methods, including self-reporting instruments such as questionnaires and diaries; (b) phone-based applications that help to record activities performed daily; and (c) wearable devices that record fitness and vital parameters in a continuous manner. However, most of the recent studies are based on mobile applications and/or fitness trackers to avoid subjective measurement, leading to wrong estimations (e.g., typically lower than self-reported estimations [16]). Among the fitness trackers, bracelets usually worn on the wrist can be today considered as the gold standard device used for activity tracking [17]. Furthermore, most of these fitness bracelets have complementary applications for interacting with social media to allow users to post their sleep and activity data, making these devices always more and more common. This has spawned a new trend, especially in the younger generations, and the total sales of fitness trackers are projected to be USD 6 billion by the end of 2020 [18].

Recently, Arigo et al. [19] described the history and future of the wearable devices used in medicine. Briefly, the earliest uses of technology to support medicine interventions occurred in the late 1940s and 1950s with the use of mechanical counters to provide feedback on users’ behavior. Pedometers (meant as early-stage mechanical devices that collect ambulatory data) were first used in the treatment of obesity in 1949 [20]. Later versions of activity sensors, such as aligned wrist- and ankle-worn counters [21], paved the way for modern smartphones and wearable fitness trackers. Most of these systems are equipped with accelerometers that record accelerations in one or more planes. These data elements are then processed into more meaningful variables [7], such as step counts; time spent in sedentary, light, moderate, and vigorous PA; flights of stairs climbed; and hours of sleep [22]. Steps are the basic parameter for several other indirect measurements. They are objective, intuitive, and comprehensible in the context of understanding personal activity, which makes this measure ideal for people to reflect on [23]. Steps are recorded in the device when a vertical acceleration deflects a spring-suspended lever arm above a designated force sensitivity threshold [24]. Most of the other common fitness tracker measures (e.g., flights of stairs, active minutes, calories burned, etc.) are then derived from the step count [25]. However, questions remain about the accuracy of the data they collect [26] and whether appropriate validation occurs before commercial sale [27].

In recent years, many studies have shown the importance of PA for long-term cardiovascular health [28]. Similarly, the number of studies considering patients’ PA in cancer clinical trials is rapidly increasing. Recently, Cox et al. [29] reviewed the different types of data recorded in cancer clinical trials, Purswani et al. [24] reviewed oncological studies specifically considering the patient’s steps, and Gresham et al. [30] looked at oncology trials based on wearable activity monitors. In general, the trend shows a rising number of studies involving some form of PA analysis, and the population is always more willing to share personal data, especially for research purposes [13]. In oncology, PGHD may be useful in providing continuous, dynamic, and objective assessments of patients’ health status between clinician visits. In general, medical doctors typically suggest that oncology patients engage in several PAs to keep a healthy status [31]. However, for several cancer types, the effects of PA on cancer prevention, treatment, and survival are still not known. An example is thyroid cancer for which the literature reports controversial results. Kitahara et al. [32] observed an increased risk of thyroid cancer in subjects reporting a higher frequency of PA. Conversely, the results reported by Leitzmann et al. [33] suggest that PA is unrelated to total thyroid cancer. Finally, Rossing et al. [34] support the hypothesis that PA may reduce the risk of thyroid cancer, but such a hypothesis is too sparse to make a more definitive judgment and give robust guidelines to patients. Like for thyroid, for several other cancer types we can also find in the literature controversial studies confirming that today, the health and fitness data at our disposal are not able to clarify the relations between cancer and PA. New technologies for collecting fitness and health data and better data accuracy may significantly improve the reliability of scientific studies in the field [35], and having large datasets reporting timeline PA and patients’ clinical status at the scientific community’s disposal would help in better profiling patients and understanding the correlations in order to improve people’s wellbeing [36].

In this work, we considered a basic parameter for PA evaluation—the number of steps taken daily. Our aim was to give the users an idea about how much steps they miss when measuring them through a smartphone-based application. In particular, we compared six fitness tracking applications for Android mobiles and three commercial fitness tracking wristbands, and we analyzed the precision and accuracy of the phone-based applications versus the dedicated wearable devices. Several brands and models of consumer trackers were examined for their accuracy in step measurement in a laboratory setting [37], e.g., treadmill walking [38], level walking [39], and stair walking [40]. However, count accuracy in real environments remains a major challenge [41]. To assess the accuracy and precision of the considered trackers, we performed two types of experiments (Figure 1). The first experiment was similar to those performed by Case et al. [42] and Modave et al. [43]. Basically, we evaluated the accuracy of the trackers in controlled outdoor tests with known ground truth, i.e., the real number of steps counted manually by analyzing videos recorded with a camera to serve as the benchmark (Figure 1a) [44]. In the second experiment, we asked a healthy 35-year-old man to install the six applications in his mobile and at the same time, wear all the fitness wristbands, and we measured the precision of the different systems in a 2-month 24 h/7 days experiment (Figure 1b). All the collected data and acquired videos are publicly available on FigShare (https://doi.org/10.6084/m9.figshare.c.4923645.v2).

Figure 1.

Figure 1

Representation of performed experiments. (a) Outdoor controlled test with number of steps counted by processing a video recorded with a camera. (b) Two-month 24 h/7 days monitoring of a healthy 35-year-old man wearing three fitness wristbands and carrying a mobile with six running step-counter applications.

The results obtained show that despite the good accuracy of all the tracking systems, the mobile applications did not provide reliable data in the long-term analysis due to an intrinsic problem, a missing parameter—the length of time the mobile was carried. Basically, in daily routines, mobiles are not always carried by people, especially when acting in a small indoor environment and performing standard daily life activities (e.g., cleaning, cooking, visiting the toilet), and this may generate unreliable day-based measurements. Generally, most of the time, young people carry their mobiles, so the number of steps recorded is reliable, but this is a very different situation for elders. In our case, even though the man performing the experiment was aware of the purpose of the collected data, the difference between the number of steps recorded by the phone-based applications was, on average, 30% lower with respect to what was recorded by the fitness wristbands, and this probably was misleading for all types of subsequent statistics, especially if the data were collected for clinical trials. Furthermore, these noncredible data may be understood by patients as being trustworthy and may also have a negative impact on users’ behavior.

We decided to share our data to make the scientific community aware that many studies based on steps counted with smartphone-based applications may be unreliable. Several recent as well as ongoing studies are based on data collected using smartphone-based applications [45], but our data show that the findings of these studies should be reconsidered. In our opinion, the only way to collect reliable data is to use an accurate fitness tracker worn on someone’s body for 24 h a day, 7 days a week. A major limitation of these devices is that they may not be sensitive enough for non-ambulatory physical activities such as cycling, swimming, and dancing [24]. Furthermore, most of them become unreliable when used for people with disabilities [46]. However, they are still a better compromise available today to collect reliable data passively without influencing people’s lives.

2. Materials and Methods

2.1. Phone-Based Applications and Wearable Fitness Trackers

Today, the market offers a wide range of phone-based applications and wearable devices for fitness tracking [47]. They differ in terms of available hardware and software installed, and it is known that the accuracy depends on both software and hardware [48]. However, even when the operating system, application programming interface (API), and sensors are the same, different implementations can affect the computation of the number of steps.

In this work, we mimicked a user interested in installing an application for fitness tracking by downloading one from among those freely available. The applications and devices included in this study were selected considering different software companies, prices, sensors, and algorithms used to analyze the data. Our decision was to install the applications in a mid-range smartphone, considering this to be the representative technology of the average consumer today. In particular, all of the applications were downloaded from the Google Play store and were installed on a Huawei P Smart FIG-LX1 phone with the Android 9 operating system.

In this work, 6 phone-based fitness tracking applications (APPs) and 3 wearable fitness trackers (WFTs) were tested. The 6 applications were:

The 3 wearable fitness trackers were:

2.2. Tracker Accuracy: Experiment Description

To assess how closely the different trackers agreed, we asked 3 operators to perform a test carrying a mobile with the 6 apps installed in a trouser pocket and wearing the 3 fitness wristbands on their left arm. The operators were 3 healthy subjects: a 35-year-old man (hereafter, Operator1), a 65-year-old man (Operator2), and a 65-year-old woman (Operator3). We asked each operator to walk in a fairly flat park while counting approximately 1200 steps. For the test, we chose this outdoor environment and not an indoor treadmill because it is known that in real-world conditions, especially on difficult terrain, there can be far more variation in step counts, given the changes in gait and wrist movement [43]. To have the ground truth, a cameraman recorded a video by following the operator performing the test with a camera. The acquired videos were post-processed to count the actual number of steps. Accuracy was then assessed by comparing the number of steps recorded by each tracker with the ground truth. All videos considered in the experiments are publicly available on FigShare (https://doi.org/10.6084/m9.figshare.c.4923645.v2).

2.3. Tracker Precision: Experiment Description

To evaluate the precision of the different trackers, we performed a long-term experiment based on the one-day test lasting for a few months in order to collect 60 days of reliable data. Basically, we asked an operator to carry the mobile with apps installed and wear the fitness wristbands 24 h/7 days. Then, we kept the data of the first 60 days, in which all the tracking systems were working. Precisely, every time one of the tracking systems was under recharge, we discarded the data collected by all the other systems. Furthermore, all the days when the operator could wear the wristbands but not carry the mobile in a trouser pocket (due to performing activities in his free time that could potentially damage the smartphone, for instance swimming, working in a vegetable garden, riding a horse, dancing) were removed from the analysis.

The operator was Operator1, a healthy 35-year-old man who leads a standard office job life (he is a computer scientist researcher) with several typical activities like working at the computer, answering the office phone, going to the printer, sharing documents with colleagues, and meeting with collaborators. The raw data recorded by different trackers are reported in Table 1. Once again, it is worth remarking that the 60 days considered in the experiment were not continuous, mainly due to battery recharge issues of the wearable devices and operator needs.

Table 1.

Steps recorded by trackers in step-controlled experiments.

Operator Operator1 Operator2 Operator3
GROUND TRUTH [steps] 1027 1409 1175
APP1 [steps] 1036 1410 1176
APP2 [steps] 1036 1410 1176
APP3 [steps] 1036 1410 1176
APP4 [steps] 1036 1293 1095
APP5 [steps] 1036 1410 1176
APP6 [steps] 1036 1410 1176
WFT1 [steps] 1016 1380 1230
WFT1 [steps] 944 1424 1197
WFT1 [steps] 994 1402 1159
APP1 (PAND) 0.88 0.07 0.09
APP2 (PAND) 0.88 0.07 0.09
APP3 (PAND) 0.88 0.07 0.09
APP4 (PAND) 0.88 8.23 6.81
APP5 (PAND) 0.88 0.07 0.09
APP6 (PAND) 0.88 0.07 0.09
WFT1 (PAND) 1.07 2.06 4.68
WFT1 (PAND) 8.08 1.06 1.87
WFT1 (PAND) 3.21 0.50 1.36

2.4. Statistics

In the accuracy assessment, the absolute normalized difference percentage (PAND) between step value (Vi) recorded by the trackers (i) and ground truth (G), determined in the post-processing of the videos, was computed to measure the closeness of agreement of the different counts according to Equation (1):

PAND = 100 × |ViG|/G (1)

In the precision assessment, unbalanced one-way analysis of variance (ANOVA) was performed to measure if the step values recorded daily by the apps significantly differed from those recorded by the fitness wristbands. Then, the normalized difference percentage (PND) between the values (Vi) recorded by the trackers (i) and the average value (A), computed considering the values of apps (Aa) or wearables (Aw) together, was calculated to evaluate the precision of each tracker i, according to Equation (2):

PND = 100 × (ViAa/w)/Aa/w (2)

The tests were carried out using MATLAB (MathWorks, Inc., Natick, MA, USA), and a p-value ≤ 0.05 was considered statistically significant. The asterisks in column 1 of Table 2 are only intended to flag levels of significance for three of the most commonly used levels: p-value less than 0.05 is flagged with one asterisk (*), p-value less than 0.01 is flagged with two asterisks (**), and p-value less than 0.001 is flagged with three asterisks (***). The bold values reported in column 1 of Table 2 highlight the days when the step values recorded by the apps did not significantly differ (considering p-value = 0.05 as the threshold) from those recorded by the fitness wristbands. The same analysis was repeated by accumulating the steps and subdividing the data in 6 blocks of 10 days (Table 3).

Table 2.

Steps recorded by trackers in the 2-month experiment. * p-value less than 0.05; ** p-value less than 0.01; *** p-value less than 0.001. Bold values in column 1 highlight days when step values recorded by APPs do not significantly differ (considering p-value = 0.05 as the threshold) from those recorded by fitness wristbands (WFTs).

Day APP1 APP2 APP3 APP4 APP5 APP6 WFT1 WFT2 WFT3
01 * 6767 5000 6203 6100 6328 6140 7139 7216 7899
02 ** 5507 5389 5070 5400 5310 4594 5907 6095 6631
03 *** 5015 5015 4760 5000 5082 5015 6114 6387 7326
04 16,234 16,150 15,469 16,100 15,951 16,150 15,082 20,687 18,774
05 *** 5363 5286 4823 4900 5233 5286 6596 9336 8853
06 *** 1188 1188 1004 1200 792 1188 4011 6405 5018
07 *** 5296 5255 4319 5300 5255 5255 7110 8817 8102
08 ** 1793 1793 1589 1700 1793 1733 2759 3991 5452
09 13,997 629 13,699 629 629 629 10,112 13,966 14,618
10 * 11,305 3662 11,047 2000 3663 3674 12,090 14,023 13,480
11 ** 5568 4337 4651 2600 4169 5443 8661 7564 6381
12 8846 2396 8426 3800 8708 8738 8835 10,962 10,372
13 *** 6299 6199 5959 4800 6101 6059 9633 8314 9241
14 ** 9158 8931 7976 8000 8488 9621 10,356 11,972 11,192
15 ** 4966 2764 4508 3400 3383 3591 5848 6504 6120
16 ** 10,179 10,493 9640 10,000 10,493 10,103 11,770 17,065 15,826
17 *** 6926 6926 6046 6200 6924 6926 9917 10,366 10,291
18 *** 2777 2788 2631 2600 2604 2788 5159 5013 5893
19 *** 3948 3948 3846 4100 3907 3948 6666 5785 6068
20 6050 6154 9211 6900 6154 6048 8000 8831 8543
21 * 7798 7798 6052 5000 7652 7798 9306 8831 9062
22 *** 4036 3988 4858 4400 3988 3988 6354 5841 7265
23 * 6403 6403 6429 4200 6403 6403 7613 8051 7811
24 *** 1306 1306 1155 2100 1306 1306 3105 2880 3466
25 *** 2891 2862 2840 2700 2772 2862 4858 4592 5199
26 ** 4741 4413 4259 5800 4399 4393 7262 6573 5391
27 * 3800 3800 3615 4000 3800 3800 5618 4752 4107
28 12,487 12,410 12,414 14,000 12,410 12,410 11,813 16,608 16,767
29 6442 6395 6107 6500 6252 6309 5275 9551 8598
30 ** 5220 4987 4818 3800 4987 4987 6131 6130 7361
31 * 5505 5373 5154 9600 5370 5373 9108 8936 8252
32 *** 3067 3059 2740 2600 3057 2991 6646 5655 6898
33 *** 6972 7189 6748 8900 7187 6817 10,567 10,244 10,292
34 4645 4428 4015 6500 4428 4428 4838 5860 6421
35 *** 3188 3023 2967 3800 2964 3023 6174 7824 8364
36 *** 4045 3921 3565 4600 3921 3921 9744 10,198 9900
37 ** 11,294 11,035 10,648 9400 11,035 11,035 13,264 19,936 19,899
38 *** 6323 6187 5705 6000 6041 6187 8226 8135 8289
39 *** 3919 3697 3278 3500 3563 3697 6939 5700 5900
40 * 6113 5809 5296 4900 5809 5809 7062 6118 7123
41 ** 6765 6574 6232 8900 6574 6574 9763 9020 9004
42 *** 8707 8617 8305 9000 8587 8617 10,972 12,499 13,511
43 *** 5132 5129 5142 4700 5129 5129 7411 10,038 10,260
44 * 7439 7487 7252 8200 7311 7436 7536 11,673 12,831
45 11,226 11,226 10,800 7600 11,226 11,226 11,935 12,368 12,228
46 *** 4729 4731 4458 4200 4580 4729 6836 7442 8118
47 17,699 17,699 17,271 10,900 17,560 17,699 17,440 20,016 18,621
48 * 6055 6055 5863 6700 5851 6055 6396 6533 7151
49 ** 13,563 13,188 13,309 11,200 13,188 13,188 13,889 17,786 18,717
50 7744 7744 7600 12,100 7606 7606 10,101 8938 10,198
51 *** 2473 2473 2400 2400 2407 2407 5109 4265 4340
52 *** 4694 4694 4631 3900 4498 4694 7346 6078 6859
53 *** 5578 5408 5456 5400 5385 5577 7974 7373 9056
54 *** 4435 4363 3986 3200 4363 4363 6572 6236 6530
55 * 3257 3228 2992 3700 3228 3228 4890 9674 5193
56 ** 4279 4249 4120 4900 4246 4249 7162 11,407 7133
57 *** 6719 6553 6468 4600 6553 6553 9663 10,120 11,205
58 4304 3981 3807 3700 3917 3981 5891 6018 7882
59 ** 7811 7651 7370 9700 7651 7532 9423 10,990 11,043
60 *** 10,967 10,967 10,752 11,000 10,967 10,967 14,003 14,171 14,559

Table 3.

Cumulative number of steps recorded subdividing the data reported in Table 2 in 6 blocks of 10 days. Asterisks in column 1 highlight days when step values recorded by APPs significantly differ from those recorded by fitness wristbands (WFTs). * p-value less than 0.05; ** p-value less than 0.01; *** p-value less than 0.001.

Block APP1 APP2 APP3 APP4 APP5 APP6 WFT1 WFT2 WFT3
I ** 72,465 49,367 67,983 48,329 50,036 49,664 76,920 96,923 96,153
II *** 64,717 54,936 62,894 52,400 60,931 63,265 84,845 92,376 89,927
III *** 55,124 54,362 52,547 52,500 53,969 54,256 67,335 73,809 75,027
IV *** 55,071 53,721 50,116 59,800 53,375 53,281 82,568 88,606 91,338
V *** 89,059 88,450 86,232 83,500 87,612 88,259 10,2279 11,6313 12,0639
VI *** 54,517 53,567 51,982 52,500 53,215 53,551 78,033 86,332 83,800

3. Results

3.1. Tracker: Accuracy: Results

To assess the accuracy of the trackers, we asked three operators to wear the devices and walk in a park while counting approximately 1200 steps. To have the ground truth number of steps, a cameraman followed the operator and recorded a video that was subsequently used to determine the real number of steps. Table 1 reports the name of the operator performing the test in row 1, the ground truth number of steps in row 2, the number of steps recorded by the devices in rows 3–11, and the PAND values in rows 12–21. It is worth noting that all apps counted the same number of steps in all tests, except APP4 in the test performed by Operator2 and Operator3 (Figure 2a). However, all PAND values were lower than 10% (the worst PAND was 8.23% for the apps and 8.08% for the wristbands), proving the accuracy of all the trackers in a short-term analysis performed under the controlled conditions of a standard walk in a park.

Figure 2.

Figure 2

Bar-charts showing (a) absolute normalized difference percentage (PAND) values reported in the last nine rows of Table 1, and (b) day-based averages of the APPs and WFTs step values reported in Table 2. The gray bars in (b) are the standard deviations. * p-value less than 0.05; ** p-value less than 0.01; *** p-value less than 0.001. Bold values in the x-axis of (b) highlight days when step values recorded by APPs do not significantly differ (considering p-value = 0.05 as the threshold) from those recorded by fitness wristbands (WFTs).

3.2. Tracker Precision: Results

To analyze the precision of the trackers, PND values were computed considering Aa as a normalization factor for apps and Aw for the fitness trackers. Table 2 reports the steps counted by the trackers in the 60-day experiment. Day-based average values and standard deviations of APPs and WFTs are reported in Figure 2b. PND values are reported in Table 4. The average PND computed by considering all the data collected (last line of Table 4) ranges from −3% to 8% for apps and −6% to 4% for wearables, showing good precision of the trackers. The same analysis was repeated not just day-based, but also accumulating the steps and subdividing the data in 6 blocks of 10 days. Table 3 reports the cumulative step numbers and Table 5 the block-based PND values. The average PND computed by considering the 6 blocks together (last line of Table 5) ranges from −4% to 8% for apps and −8% to 4% for wearables. This shows that despite some local values strongly differing from the average, across the whole experiment, there were no significant differences between the APPs or WFTs considered separately. Accordingly, this proves that today, despite recorded values being logically dependent on the quality of the algorithms, on average, thanks to the available technology, all apps and wearables gave practically the same number of counted steps in long-term analysis.

Table 4.

Percentage normalized difference (PND) values computed for trackers in the 2-month experiment.

DAY APP1 APP2 APP3 APP4 APP5 APP6 WFT1 WFT2 WFT3
01 11 −18 2 0 4 1 −4 −3 6
02 6 3 −3 4 2 −12 −5 −2 7
03 1 1 −4 0 2 1 −7 −3 11
04 1 1 −3 1 0 1 −17 14 3
05 4 3 −6 −5 2 3 −20 13 7
06 9 9 −8 10 −28 9 −22 24 −2
07 4 3 −16 4 3 3 −11 10 1
08 3 3 −8 −2 3 0 −32 −2 34
09 178 −88 172 −88 −88 −88 −22 8 13
10 92 −38 87 −66 −38 −38 −8 6 2
11 25 −3 4 −42 −7 22 15 0 −15
12 30 −65 24 −44 28 28 −12 9 3
13 7 5 1 −19 3 3 6 −8 2
14 5 3 −8 −8 −2 11 −7 7 0
15 32 −27 20 −10 −10 −5 −5 6 −1
16 0 3 −5 −1 3 0 −21 15 6
17 4 4 −9 −7 4 4 −3 2 1
18 3 3 −2 −4 −3 3 −4 −6 10
19 0 0 −3 4 −1 0 8 −6 −2
20 −10 −9 36 2 −9 −10 −5 4 1
21 11 11 −14 −29 9 11 3 −3 0
22 −4 −5 15 5 −5 −5 −2 −10 12
23 6 6 6 −30 6 6 −3 3 0
24 −8 −8 −18 49 −8 −8 −1 −9 10
25 2 1 1 −4 −2 1 −1 −6 6
26 2 −5 −9 24 −6 −6 13 3 −16
27 0 0 −5 5 0 0 16 −2 −15
28 −2 −2 −2 10 −2 −2 −22 10 11
29 2 1 −4 3 −1 0 −32 22 10
30 9 4 0 −21 4 4 −6 −6 13
31 −9 −11 −15 58 −11 −11 4 2 −6
32 5 5 −6 −11 5 2 4 −12 8
33 −5 −2 −8 22 −2 −7 2 −1 −1
34 −2 −7 −15 37 −7 −7 −15 3 13
35 1 −4 −6 20 −6 −4 −17 5 12
36 1 −2 −11 15 −2 −2 −2 3 0
37 5 3 −1 −12 3 3 −25 13 12
38 4 2 −6 −1 −1 2 0 −1 1
39 9 2 −9 −3 −1 2 12 −8 −5
40 9 3 −6 −13 3 3 4 −10 5
41 −2 −5 −10 28 −5 −5 5 −3 −3
42 1 0 −4 4 −1 0 −11 1 10
43 1 1 2 −7 1 1 −20 9 11
44 −1 0 −4 9 −3 −1 −29 9 20
45 6 6 2 −28 6 6 −2 2 0
46 3 3 −2 −8 0 3 −8 0 9
47 7 7 5 −34 7 7 −7 7 0
48 −1 −1 −4 10 −4 −1 −4 −2 7
49 5 2 3 −13 2 2 −17 6 11
50 −8 −8 −10 44 −9 −9 4 −8 5
51 2 2 −1 −1 −1 −1 12 −7 −5
52 4 4 2 −14 0 4 9 −10 1
53 2 −1 0 −1 −2 2 −2 −9 11
54 8 6 −3 −22 6 6 2 −3 1
55 0 −1 −9 13 −1 −1 −26 47 −21
56 −1 −2 −5 13 −2 −2 −16 33 −17
57 8 5 4 −26 5 5 −6 −2 8
58 9 1 −4 −6 −1 1 −11 −9 19
59 −2 −4 −7 22 −4 −5 −10 5 5
60 0 0 −2 1 0 0 −2 −1 2
AVERAGE 8 −3 2 −3 −3 −1 −6 2 4

Table 5.

Percentage normalized difference (PND) values computed analyzing the 6 blocks of cumulative steps reported in Table 3.

Block APP1 APP2 APP3 APP4 APP5 APP6 WFT1 WFT2 WFT3
I 29 −12 21 −14 −11 −12 −15 8 7
II 8 −8 5 −12 2 6 −5 4 1
III 2 1 −2 −2 0 1 −7 2 4
IV 2 −1 −8 10 −2 −2 −6 1 4
V 2 1 −1 −4 0 1 −10 3 7
VI 2 1 −2 −1 0 1 −6 4 1
AVERAGE 8 −3 2 −4 −2 −1 −8 4 4

However, the number of steps recorded by the phone-based apps was significantly lower than that recorded by the fitness wristbands. The average number of steps recorded daily by the phone-based apps was on average 34% lower than that recorded by the fitness wristbands (Figure 2b) according to the day-based analysis, and 32% in the cumulative-based one. Furthermore, on approximately 80% of the days (50 out of 60 days), the values recorded by the phone-based apps statistically significantly differed from those recorded by the wearable devices, according to an unbalanced one-way ANOVA test performed on the day-based data. This suggests lower accuracy of the apps in long-term analysis with respect to wearables worn on the body. This is also emphasized when considering the cumulative-based data reported in Table 3: in 100% of the 6 blocks, the cumulative values referring to the phone-based apps strongly (Block I is characterized by a p-value lower than 0.01; all the other blocks by p-values lower than 0.001) statistically significantly differed from those referring to the wearable devices.

It is worth remarking that the operator performing the experiment was well informed about the finality of the acquired data. However, to collect reliable data, he did not modify his daily routine and the way he used his mobile. Accordingly, he was not carrying the mobile during several daily movements typical of a standard office job, like standing from the desk for answering the office phone, going to the printer, bringing documents to colleagues, and visiting the toilet. Furthermore, during his free time (mainly in the evenings at home), he was not carrying the mobile during standard activities like cooking and cleaning. The recorded data proved that these standard movements strongly affect the final count of steps taken, and the difference between steps recorded by phone-based apps and fitness wristbands would be even larger for elderly people, who typically leave their mobile on a desk in a central room of the house and perform standard activities in the environment.

4. Discussion

One of the goals of this work was to compare the accuracy and precision of smartphone-based apps versus those of wearable fitness wristbands to suggest the best way to collect data for long-term clinical trials. Even though several research studies have confirmed that both the accuracy and precision of activity tracking devices have steadily improved over the last decade, device accuracy still remains a concern. However, technological improvements, increased knowledge on how to use the devices and for what purposes, and a better statistical approach to understanding the data all contribute to more comfort in the use of wearables and sensors for clinical trials.

Logically, to be effective in measuring PA, patients must wear a wristband or use an app for the entire day. Therefore, design, battery life, water-resistance, and comfort must all be maximized [29]. However, since in daily life people are not always carrying their smartphone, data collected by phone-based apps may be unreliable for long-term analysis, and asking people to carry their smartphone 24 h a day, 7 days a week would be impossible and would definitively change their lifestyle. Besides, other studies already proved that even fitness wristbands generally slightly underestimate the number of steps [38]. Consequently, there are several reasons to suggest that data obtained by smartphone-based apps are unreliable. On the other hand, fitness wristbands: (a) are somewhat invasive; (b) do not influence people’s lifestyle; and (c) can collect accurate and precise data for long-term analysis. However, since foot pods measure walking or running cadence directly, we do not exclude the idea that more reliable data could be acquired using ankle bracelets, which are probably more accurate than devices measuring at the wrist or the hip [43]. Previous comparisons of data from various consumer- and commercial-grade wearables already demonstrated variability among devices related to body placement. For instance, Hildebrand et al. [49] examined the effects of tracker placement on acceleration values. In particular, they showed a significant difference between hip and wrist placement, showing that the output from the wrist was generally higher than that from the hip. A hip tracker usually has several limitations, including underestimation of energy expenditure during activities with little or no movement at the hip and potential loss of data due to removing the tracker when dressing, and influencing the lifestyle. On the other hand, several studies have documented noncompliance resulting in loss of data when using a hip-mounted accelerometer [16,50].

Actually, how to improve the general accuracy of step counting still remains a very important issue. For instance: (a) by exploiting the decreasing trend of the prices of electronics and the increasing size-reduction of all the sensors, three sensors could be embedded in all the devices to always provide a median value; (b) GPS measurements of the distances that have been walked or ran could be considered in all step counting algorithms to improve the accuracy of the system; (c) other less noise-prone body placement positions could be tested, for instance the neck or waist, or smart wearable technologies, such as smart shirts or pants, could be considered. However, with the information available today, we think that the best trade-off in collecting reliable data without affecting people’s lifestyle is offered by wearable fitness wristbands. Therefore, we suggest that these types of devices be used for long-term clinical trials, and we caution the community to reconsider the findings of previous studies based on smartphone applications.

5. Conclusions

At this time, the number of clinical trials involving physical activity measurements is growing. Smartphone-based applications, fitness wristbands, ankle bracelets, hip belts, and many other tracking systems are very common in society. However, the accuracy and precision of these devices still remain a concern.

In this work, we analyzed the precision and accuracy of six phone-based applications (i.e., APP1—Huawei Health; APP2—Bits&Coffee ActivityTracker; APP3—Best Simple Apps Contapassi; APP4—GALA MIX WinWalk; APP5—LG Electronics LG Health; APP6—Pacer Health’s Pacer) and three wearable fitness wristbands (i.e., WFT1—Decathlon OnCoach 100; WFT2—Crane activity tracker; WFT3—Suunto 9). The experiments performed were conceived as a proof of concept to give an idea about what can be expected in terms of relative differences in the measurements achieved using different system typologies. In particular, the number of steps recorded by the trackers in controlled tests with ground truth was considered to assess the accuracy of the trackers; a long-term analysis based on data acquired in a 2-month experiment was considered to estimate the precision. The first experiment performed proves that the accuracy of the smartphone applications is comparable to that of the wearable fitness wristbands; the second experiment proves that due to the fact that people cannot always carry a smartphone, the step measurement in long-term analysis may differ even by 30%. Providing significant statistics about the absolute performance of mobile applications and fitness wristbands is beyond the scope of this work. However, we can reassume that between the applications, just APP4 gave significantly different results, and between the wristbands, WFT1 gave, in general, lower step measurements.

The main outcome of the experiments is that despite good accuracy in short-term analysis of controlled conditions, data acquired with phone-based applications may be unreliable in long-term analysis. This not due to system accuracy, but because people do not always carry their smartphone in their trouser pocket. For instance, they typically leave their mobile on a desk in a central room of the house and do not carry their smartphone when performing standard daily life activities (e.g., cleaning, cooking, visiting the toilet) in small indoor environments, and we proved that the sum of these moments, added to the moments when they do not carry their mobile because performing activities that could potentially damage it (e.g., swimming, working in the vegetable garden, riding a horse, dancing), at the end of the day, may have a significant impact on step measurement.

To conclude, besides suggesting the use of wearable fitness wristbands to collect data, we also caution the scientific community to reconsider outcomes of studies based on data collected with mobile trackers.

Acknowledgments

We would like to thank Mattia Cantagalli (Faenza, Italy) and Roberto Montevecchi (Faenza, Italy) for sharing important opinions about fitness trackers; Roberto Vespignani (IRST IRCCS, Meldola, Italy) and Nicola Caroli (IRST IRCCS, Meldola, Italy) for technical assistance in testing applications/trackers; Amedeo Bertuccioli (University of Bologna, Italy) for analyzing the videos; Roberta Vicchi (Ravenna, Italy) for editing the manuscript; the MDPI English Editing Services for revising the manuscript language.

Author Contributions

Conceptualization: F.P., G.M., A.C.; data curation: F.P.; formal analysis: F.P., A.C.; funding acquisition: G.M., A.C.; investigation. F.P., A.C.; methodology: F.P., A.C.; project administration: A.C.; resources: G.M., A.C.; software: F.P.; supervision: A.C.; validation: F.P.; visualization: F.P.; writing—original draft: F.P., A.C.; writing—review and editing: G.M. All authors have read and agreed to the published version of the manuscript.

Funding

G.M. is supported by Horizon 2020—ONCORELIEF EU Project (ref: H2020-875392). This research received no other funding.

Conflicts of Interest

The authors declare no conflict of interest.

Ethics Statements

It is worth noting that this is not a clinical study/trial. In this research, there are no patients and the operators involved in the experiments were volunteers just carrying a smartphone and wearing three fitness wristbands. We are not sharing personal health data or sensible data and the experiments have been designed only to test tracking systems. However, all the operators involved in the experiments signed the informed consent to authorize the treatment of the collected data. Their consent is publicly available: https://doi.org/10.6084/m9.figshare.c.4923645.v2.

Footnotes

Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.Jee H. Review of researches on smartphone applications for physical activity promotion in healthy adults. J. Exerc. Rehabil. 2017;13:3–11. doi: 10.12965/jer.1732928.464. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Zhao S., Li S., Ramos J., Luo Z., Jiang Z., Dey A.K., Pan G. User profiling from their use of smartphone applications: A survey. Pervasive Mob. Comput. 2019;59:101052. doi: 10.1016/j.pmcj.2019.101052. [DOI] [Google Scholar]
  • 3.Kang J.J., Adibi S. Systematic predictive analysis of personalized life expectancy using smart devices. Technologies. 2018;6:74. doi: 10.3390/technologies6030074. [DOI] [Google Scholar]
  • 4.Bayo-Monton J.L., Martinez-Millana A., Han W., Fernandez-Llatas C., Sun Y., Traver V. Wearable sensors integrated with Internet of Things for advancing eHealth care. Sensors. 2018;18:1851. doi: 10.3390/s18061851. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Kranz M., MöLler A., Hammerla N., Diewald S., PlöTz T., Olivier P., Roalter L. The mobile fitness coach: Towards individualized skill assessment using personalized mobile devices. Pervasive Mob. Comput. 2013;9:203–215. doi: 10.1016/j.pmcj.2012.06.002. [DOI] [Google Scholar]
  • 6.Sadeghi R., Banerjee T., Hughes J.C., Lawhorne L.W. Sleep quality prediction in caregivers using physiological signals. Comput. Biol. Med. 2019;110:276–288. doi: 10.1016/j.compbiomed.2019.05.010. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Purswani J.M., Dicker A.P., Champ C.E., Cantor M., Ohri N. Big data from small devices: The future of smartphones in oncology. Semin. Radiat. Oncol. 2019;29:338–347. doi: 10.1016/j.semradonc.2019.05.008. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Dias D., Silva Cunha J.P. Wearable health devices—Vital sign monitoring, systems and technologies. Sensors. 2018;18:2414. doi: 10.3390/s18082414. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Heintzman N.D. A digital ecosystem of diabetes data and technology: Services, systems, and tools enabled by wearables, sensors, and apps. J. Diabetes Sci. Technol. 2016;10:35–41. doi: 10.1177/1932296815622453. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Villarreal V., Nielsen M., Samudio M. Sensing and storing the blood pressure measure by patients through a platform and mobile devices. Sensors. 2018;18:1805. doi: 10.3390/s18061805. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Sazonov E., Lopez-Meyer P., Tiffany S. A wearable sensor system for monitoring cigarette smoking. J. Stud. Alcohol Drugs. 2013;74:956–964. doi: 10.15288/jsad.2013.74.956. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Lee J.W., Han D.C., Shin H.J., Yeom S.H., Ju B.K., Lee W. PEDOT: PSS-based temperature-detection thread for wearable devices. Sensors. 2018;18:2996. doi: 10.3390/s18092996. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Kessel K.A., Vogel M.M., Kessel C., Bier H., Biedermann T., Friess H., Herschbach P., von Eisenhart-Rothe R., Meyer B., Kiechle M., et al. Mobile health in oncology: A patient survey about app-assisted cancer care. JMIR mHealth uHealth. 2017;5:e81. doi: 10.2196/mhealth.7689. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Kang X., Huang B., Qi G. A novel walking detection and step counting algorithm using unconstrained smartphones. Sensors. 2018;18:297. doi: 10.3390/s18010297. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Rajan K., Garofalo E., Chiolerio A. Wearable intrinsically soft, stretchable, flexible devices for memories and computing. Sensors. 2018;18:367. doi: 10.3390/s18020367. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Troiano R.P., Berrigan D., Dodd K.W., Masse L.C., Tilert T., McDowell M. Physical activity in the United States measured by accelerometer. Med. Sci. Sports Exerc. 2008;40:181–188. doi: 10.1249/mss.0b013e31815a51b3. [DOI] [PubMed] [Google Scholar]
  • 17.Mansukhani M.P., Kolla B.P. Apps and fitness trackers that measure sleep: Are they useful. Clevel. Clin. J. Med. 2017;84:451–456. doi: 10.3949/ccjm.84a.15173. [DOI] [PubMed] [Google Scholar]
  • 18.Kinney D.A., Nabors L.A., Merianos A.L., Vidourek R.A. College students’ use and perceptions of wearable fitness trackers. Am. J. Health Educ. 2019;50:298–307. doi: 10.1080/19325037.2019.1642265. [DOI] [Google Scholar]
  • 19.Arigo D., Jake-Schoffman D.E., Wolin K., Beckjord E., Hekler E.B., Pagoto S.L. The history and future of digital health in the field of behavioral medicine. J. Behav. Med. 2019;42:67–83. doi: 10.1007/s10865-018-9966-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Larsen G. Treatment of obesity. Tidsskr. Nor. laegeforen. 1949;69:442–446. [PubMed] [Google Scholar]
  • 21.Schulmann J.L., Reisman J.M. An objective measurement of hyperactivity. Am. J. Ment. Defic. 1959;64:455–456. [PubMed] [Google Scholar]
  • 22.Burgdorf A., Güthe I., Jovanović M., Kutafina E., Kohlschein C., Bitsch J.Á., Jonas S.M. The mobile sleep lab app: An open-source framework for mobile sleep assessment based on consumer-grade wearable devices. Comput. Biol. Med. 2018;103:8–16. doi: 10.1016/j.compbiomed.2018.09.025. [DOI] [PubMed] [Google Scholar]
  • 23.Bassett D.R., Toth L.P., LaMunion S.R., Crouter S.E. Step counting: A review of measurement considerations and health-related applications. Sports Med. 2017;47:1303–1315. doi: 10.1007/s40279-016-0663-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Purswani J.M., Ohri N., Champ C. Tracking steps in oncology: The time is now. Cancer Manag. Res. 2018;10:2439. doi: 10.2147/CMAR.S148710. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.El-Amrawy F., Nounou M.I. Are currently available wearable devices for activity tracking and heart rate monitoring accurate, precise, and medically beneficial? Health Inform. Res. 2015;21:315–320. doi: 10.4258/hir.2015.21.4.315. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Evenson K.R., Goto M.M., Furberg R.D. Systematic review of the validity and reliability of consumer-wearable activity trackers. Int. J. Behav. Nutr. Phys. Act. 2015;12:159. doi: 10.1186/s12966-015-0314-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Peake J., Kerr G.K., Sullivan J.P. A critical review of consumer wearables, mobile applications and equipment for providing biofeedback, monitoring stress and sleep in physically active populations. Front. Physiol. 2018;9:743. doi: 10.3389/fphys.2018.00743. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Hershman S.G., Bot B.M., Shcherbina A., Doerr M., Moayedi Y., Pavlovic A., Waggott D., Cho M.K., Rosenberger M.E., Haskell W.L., et al. Physical activity, sleep and cardiovascular health data for 50,000 individuals from the MyHeart Counts Study. Sci. Data. 2019;6:1–10. doi: 10.1038/s41597-019-0016-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29.Cox S.M., Lane A., Volchenboum S.L. Use of wearable, mobile, and sensor technology in cancer clinical trials. JCO Clin. Cancer Inform. 2018;2:1–11. doi: 10.1200/CCI.17.00147. [DOI] [PubMed] [Google Scholar]
  • 30.Gresham G., Schrack J., Gresham L.M., Shinde A.M., Hendifar A.E., Tuli R., Rimel B.J., Figlin R., Meinert C.L., Piantadosi S. Wearable activity monitors in oncology trials: Current use of an emerging technology. Contemp. Clin. Trials. 2018;64:13–21. doi: 10.1016/j.cct.2017.11.002. [DOI] [PubMed] [Google Scholar]
  • 31.Chandwani K.D., Perkins G., Nagendra H.R., Raghuram N.V., Spelman A., Nagarathna R., Johnson K., Fortier A., Arun B., Wei Q., et al. Randomized, controlled trial of yoga in women with breast cancer undergoing radiotherapy. J. Clin. Oncol. 2014;32:1058. doi: 10.1200/JCO.2012.48.2752. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Kitahara C.M., Platz E.A., Freeman L.E.B., Black A., Hsing A.W., Linet M.S., Park Y., Schairer C., De González A.B. Physical activity, diabetes, and thyroid cancer risk: A pooled analysis of five prospective studies. Cancer Causes Control. 2012;23:463–471. doi: 10.1007/s10552-012-9896-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Leitzmann M.F., Brenner A., Moore S.C., Koebnick C., Park Y., Hollenbeck A., Schatzkin A., Ron E. Prospective study of body mass index, physical activity and thyroid cancer. Int. J. Cancer. 2010;126:2947–2956. doi: 10.1002/ijc.24913. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34.Rossing M.A., Remler R., Voigt L.F., Wicklund K.G., Daling J.R. Recreational physical activity and risk of papillary thyroid cancer (United States) Cancer Causes Control. 2001;12:881–885. doi: 10.1023/A:1013757030600. [DOI] [PubMed] [Google Scholar]
  • 35.Carbonaro A., Piccinini F., Reda R. Integrating heterogeneous data of healthcare devices to enable domain data management. J. e-Learn. Knowl. Soc. 2018;14:1–12. [Google Scholar]
  • 36.Dijkhuis T.B., Blaauw F.J., Van Ittersum M.W., Velthuijsen H., Aiello M. Personalized physical activity coaching: A machine learning approach. Sensors. 2018;18:623. doi: 10.3390/s18020623. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Tam M.K., Cheung S.Y. Validation of consumer wearable activity tracker as step measurement in free-living conditions. Finn. J. eHealth eWelfare. 2019;11:68–75. doi: 10.23996/fjhw.76673. [DOI] [Google Scholar]
  • 38.Sears T., Alvalos E., Lawson S., McAlister I., Eschbach L.C., Bunn J. Wrist-worn physical activity trackers tend to underestimate steps during walking. Int. J. Exerc. Sci. 2017;10:764–773. [Google Scholar]
  • 39.Takacs J., Pollock C.L., Guenther J.R., Bahar M., Napier C., Hunt M.A. Validation of the Fitbit One activity monitor device during treadmill walking. J. Sci. Med. Sport. 2014;17:496–500. doi: 10.1016/j.jsams.2013.10.241. [DOI] [PubMed] [Google Scholar]
  • 40.Huang Y., Xu J., Yu B., Shull P.B. Validity of FitBit, Jawbone UP, Nike+ and other wearable devices for level and stair walking. Gait Posture. 2016;48:36–41. doi: 10.1016/j.gaitpost.2016.04.025. [DOI] [PubMed] [Google Scholar]
  • 41.Ngueleu A.M., Blanchette A.K., Bouyer L., Maltais D., McFadyen B.J., Moffet H., Batcho C.S. Design and accuracy of an instrumented insole using pressure sensors for step count. Sensors. 2019;19:984. doi: 10.3390/s19050984. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 42.Case M.A., Burwick H.A., Volpp K.G., Patel M.S. Accuracy of smartphone applications and wearable devices for tracking physical activity data. JAMA. 2015;313:625–626. doi: 10.1001/jama.2014.17841. [DOI] [PubMed] [Google Scholar]
  • 43.Modave F., Guo Y., Bian J., Gurka M.J., Parish A., Smith M.D., Lee A.M., Buford T.W. Mobile device accuracy for step counting across age groups. JMIR mHealth uHealth. 2017;5:e88. doi: 10.2196/mhealth.7870. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 44.Bunn J.A., Jones C., Oliviera A., Webster M.J. Assessment of step accuracy using the Consumer Technology Association standard. J. Sports Sci. 2019;37:244–248. doi: 10.1080/02640414.2018.1491941. [DOI] [PubMed] [Google Scholar]
  • 45.Soto-Perez-De-Celis E., Kim H., Rojo-Castillo M.P., Sun C.L., Chavarri-Guerra Y., Navarrete-Reyes A.P., Waisman J.R., Avila-Funes J.A., Aguayo A., Hurria A. A pilot study of an accelerometer-equipped smartphone to monitor older adults with cancer receiving chemotherapy in Mexico. J. Geriatr. Oncol. 2018;9:145–151. doi: 10.1016/j.jgo.2017.09.008. [DOI] [PubMed] [Google Scholar]
  • 46.Jones M., Morris J., Deruyter F. Mobile healthcare and people with disabilities: Current state and future needs. Int. J. Environ. Res. Public Health. 2018;15:515. doi: 10.3390/ijerph15030515. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 47.Muzny M., Henriksen A., Giordanengo A., Muzik J., Grottland A., Blixgard H., Hartvigsen G., Arsand E. Wearable sensors with possibilities for data exchange: Analyzing status and needs of different actors in mobile health monitoring systems. Int. J. Med. Inform. 2020;133:104017. doi: 10.1016/j.ijmedinf.2019.104017. [DOI] [PubMed] [Google Scholar]
  • 48.Díaz S., Stephenson J.B., Labrador M.A. Use of wearable sensor technology in gait, balance, and range of motion analysis. Appl. Sci. 2020;10:234. doi: 10.3390/app10010234. [DOI] [Google Scholar]
  • 49.Hildebrand M., Van Hees V.T., Hansen B.H., Ekelund U.L.F. Age group comparability of raw accelerometer output from wrist-and hip-worn monitors. Med. Sci. Sports Exerc. 2014;46:1816–1824. doi: 10.1249/MSS.0000000000000289. [DOI] [PubMed] [Google Scholar]
  • 50.Colley R., Gorber S.C., Tremblay M.S. Quality control and data reduction procedures for accelerometry-derived measures of physical activity. Health Rep. 2010;21:63. [PubMed] [Google Scholar]

Articles from Sensors (Basel, Switzerland) are provided here courtesy of Multidisciplinary Digital Publishing Institute (MDPI)