Skip to main content
Oxford University Press - PMC COVID-19 Collection logoLink to Oxford University Press - PMC COVID-19 Collection
. 2020 Oct 19:ciaa1589. doi: 10.1093/cid/ciaa1589

Self-Collected Oral Fluid and Nasal Swab Specimens Demonstrate Comparable Sensitivity to Clinician-Collected Nasopharyngeal Swab Specimens for the Detection of SARS-CoV-2

N Kojima 1,, F Turner 2, V Slepnev 2, A Bacelar 2, L Deming 2, S Kodeboyina 2, J D Klausner 1
PMCID: PMC7665422  PMID: 33075138

Abstract

We compared self-collected oral fluid swab specimens with and without clinician supervision, clinician-supervised self-collected mid-turbinate (nasal) swab specimens, and clinician-collected nasopharyngeal swab specimens for the detection of SARS-CoV-2. Supervised oral fluid and nasal swab specimens performed similarly to clinician-collected nasopharyngeal swab specimens. No sample type could detect SARS-CoV-2 infections amongst all positive participants.


Articles from Clinical Infectious Diseases: An Official Publication of the Infectious Diseases Society of America are provided here courtesy of Oxford University Press