Skip to main content
Brazilian Journal of Microbiology logoLink to Brazilian Journal of Microbiology
. 2020 Sep 12;51(4):2015–2020. doi: 10.1007/s42770-020-00374-2

Separation of Escherichia coli from natural samples for identification of sources and microcosm inoculation

Marcos Tavares Carneiro 1,2, Daniel Vidal Perez 3, Renato Castiglia Feitosa 2, Julio Cesar Wasserman 4,5,
PMCID: PMC7688740  PMID: 32920714

Abstract

Obtaining uncultured Escherichia coli from natural waters is an important step in the study of microbes in the environment, which are critical for bacterial decay and microbial source tracking. The quality of the samples used can influence the assays, because high contaminant concentrations, differing cell ages, and physiologic states can impair results. The proposed separation is based on a three-step filtration method applied to replicates of seven samples from a sewage plant affluent, collected in different periods. Aliquots of the leachate were inoculated into microcosms, aiming to observe the cultivability of the cells. The assay resulted in colimetry values ranging between 104 and 105 cells. In the leachate, averages of 1.05% of total coliforms and 1.10% of Escherichia coli were recovered from original samples. Although enduring unfavorable temperatures, salinities, and nutritional conditions, the inoculated microcosm populations grew approximately 310 times after 24 h. The final leachate contained cultivable cells in appropriate physiological states and quantities for inoculum in microcosm sets. The bacteria obtained from the leachate were also appropriate for surveys of microbial source tracking, because, in the developed procedure, organisms were separated from contaminants, while cell concentrations were sufficient for inocula.

Keywords: Escherichia coli, Wastewater, Microbial source tracking, Bacteria decay, Wild strains

Introduction

Applying cultured bacteria inoculum in vitro microbiological studies can directly influence the results of the assays, because the gene expression can be very different from natural ones. This topic is particularly critical in both (a) environmental bacterial decay studies and (b) contamination source studies (microbial source tracking, MST) [13]:

In decay studies, the culture of the samples alters the gene expression of the bacteria, because culture phase transitions induce pre-adaptations to osmotic shock, including variations in temperature, salinity, solar radiation, and other parameters. Thus, by applying cultured bacteria, it becomes difficult to relate results obtained from decay assays to what would actually have occurred in the environment [46].

As a proposed alternative to fully in vitro studies, samples can be obtained directly from the environment, which contain cells that have endured different conditions, and display several different physiological states: viable and cultivable, viable but non-cultivable, and non-viable [79]. However, environmental samples do not always yield cells at sufficient concentrations and viable/suitable conditions for decay studies [811].

Effluents from sewage treatment plants are expected to contain homogeneous bacterial populations at appropriate concentrations [12]. On the other hand, sewage has high concentrations of nutrients, solid materials, and chemical contaminants, which drastically change the growth behavior of bacterial populations. Nutrients promote intensive growth, solid materials can adsorb and drag down a large number of cells to sediments, and chemical contaminants may affect growth and produce matrix effects during microbial analysis [1315]. Therefore, inoculating raw sewage water in decay experiments can impair results.

The MST studies of contamination sources use molecular markers of targeted cells [1, 3, 16], and the techniques applied for cell concentration may also lead to the chemical contaminant concentration which affects molecular analysis. On the other hand, dilution to reduce the concentrations of chemical contaminants also reduces the concentration of markers, which often hinders their detection. Besides, quantitative approaches of cells with qPCR require procedures that do not apply bioaugmentation, thereby maintaining the quantitative relationship during the analytical process [17].

The aim of this work was to develop a new technique for the separation of Escherichia coli from raw sewage, applying reverse filtration (RF). The procedure seeks to separate out bacteria from other contaminants in the sewage, to provide inocula with a minimum amount of contaminants and natural genetic diversity, with appropriate quality and quantity for microbiological assays.

Material and methods

Seven 150-mL samples of influent of a sewage treatment plant were obtained from the Oswaldo Cruz Foundation, Rio de Janeiro, Brazil. Samples were collected in November (Spring) and December (summer) in consecutive days. The samples were collected from the diverging section of a Parshall flume, after sewage had passed through the grit chamber (before any treatment). Samples were placed in 200-mL autoclaved flasks and transported under refrigeration to the laboratory which is 100 m away from the plant, and immediately processed, according to the description in Fig. 1 (total time between collection and processing was always less than 1 h).

Fig. 1.

Fig. 1

Schematic design of the reverse filtration (RF) procedure. Source: authors

Considering that bacterial size does not vary considerably [18] and oscillates around 0.8 μm [19], samples were sequentially passed through 0.8-μm and 0.45-μm membranes. Samples were thoroughly homogenized and 10 mL of the samples was passed through a mixed cellulose esters 0.80-μm Millipore® membrane and the filtrate was recovered. The membrane was replaced, and the procedure was repeated until a 50-mL filtrate was obtained. Samples were continuously homogenized between steps, the filtration samples were then reserved, and membranes were discarded.

A second filtration step was performed using a 0.45-μm filter membrane from the same manufacturer. After the second filtration, the filtrate was discarded, and the membrane containing purified bacteria was reversed (top side down) in the filtration holder (as shown in Fig. 1). Then 100 mL of sterile phosphate water (following the standard methods; [20]) were passed through the filter, leaching off bacteria. A 3-mL sample of each final leachate (phosphate water) was analyzed in a spectrophotometer at 660 nm, to verify the optical density of the bacteria suspension. The remaining leachate obtained in this reverse filtration (RF) was subsequently analyzed as follows:

  1. First, analyses of the colimetry of each raw sewage influent sample were performed with enzymatic substrate Colilert® in a Quanti-Tray system. The trays were incubated at 35 °C for 24 h

  2. Replicate colimetry of the phosphate waters (which leached 0.45-μm filters) was carried out with the same Colilert® procedure. Two subsamples of phase 1 filtrate from samples 2 and 5 were carried out, with the aim of controlling whether the filtrations at 0.80 μm were unexpectedly retaining bacteria.

  3. A second aliquot of the leachate was used to inoculate microcosms in the laboratory. In total, 750 mL of sterile phosphate water received 26.25 g of sterile NaCl, yielding a solution of 3.5% (simulating seawater) and 0.75 mL (0.1%) of Brain Heart Infusion broth. The solution was inoculated with 7.5 mL of leachate obtained from the reverse filtration. The experimental setting was divided into three 250-mL portions and transferred to a 500-mL Erlenmeyer flask, constituting triplicates with the simulated seawater.

The above-described microcosms were incubated in a 60 RPM shaker at 20 °C (room temperature, simulating natural environmental conditions) for 24 h. After this incubation period, colimetry was made as described previously.

Results and discussion

The primary results of the reverse filtration tests are presented in Table 1, where it can be observed that in all tests, total coliforms (TC) and Escherichia coli (EC) were obtained in the final leachate with the proposed reverse filtration (RF), presenting concentrations ranging from 104 to 105.

Table 1.

Colimetry average (most probable number/100 mL) in the raw sample, after 0.80-μm filtration and after reverse filtration. Reverse filtration for each sample was performed four times

Sample (n) Raw influent Control after filtration in 0.80 μm After reverse filtration in 0.45 μm (4 replicates)
Total coliforms E. coli Total coliforms E. coli Total coliforms E. coli
1 4.9E+07 9.6E+06 2.5E+06 5.4E+05 4.4E + -5 1.1E+05
2 2.4E+07 8.8E+06 1.8E+05 8.3E+04
3 5.7E+06 2.3E+06 7.1E+04 3.3E+04
4 5.7E+06 2.3E+06 5.2E+04 2.5E+04
5 1.6E+07 6.5E+06 1.9E+05 8.2E+04 1.8E+05 6.3E+04
6 1.4E+07 7.3E+06 1.8E+05 7.0E+04
7 1.3E+07 7.7E+06 1.9E+05 7.8E+04

The percentages of cells recovery shown in Table 2 ranged from 0.77% (in sample 2) of total coliforms (average 1.05 ± 0.31%) to 1.46% (in sample 3) of E. coli (average 1.10 ± 0.37%). Comparatively, the recovery after the first filtration yielded 5.04% and 5.64% of total coliforms and E. coli (sample 1) and 1.21% and 1.26% (sample 5), respectively. Thus, it is pertinent to consider that a large proportion of the bacteria were adsorbed to the solid materials, which were retained in the 0.80-μm pore filter used in the initial stage. The filtration through 0.45 μm also eliminated most of the dissolved materials as indicated by spectrometric absorbance.

Table 2.

Colimetric yield after reverse filtration (RF) and percentages of the RF leachate colimetry in relation to raw sewage

Sample Total coliforms (% in the filtrate) Escherichia coli (% in the leachate)
1 0.89 ± 0.09 1.15 ± 0.39
2 0.77 ± 0.11 0.94 ± 0.25
3 1.26 ± 0.35 1.46 ± 0.38
4 0.92 ± 0.23 1.11 ± 0.51
5 1.13 ± 0.02 0.97 ± 0.02
6 1.19 ± 0.25 0.96 ± 0.04
7 1.46 ± 0.42 1.01 ± 0.17
Average 1.05 ± 0.31 1.10 ± 0.37

Although the percentage of cell recovery did not correlate with the initial concentration (r2 = 0.223 and 0.384 for total coliforms and E. coli respectively), it was observed that the recovery approximately agreed with the decay pattern. However, there was a linear correlation between the initial and final absolute values, both for total coliforms (r2 = 0.936) and for E. coli (r2 = 0.938), as can be seen from Fig. 2.

Fig. 2.

Fig. 2

Correlation between total coliform (left) and Escherichia coli (right) in raw sewage and yield in the final filtrate (reverse filtration)

The reverse filtration method (RF) generates a translucent final leachate with an absorbance of 0.00 (at 660 nm), against milky phosphate water used as blank control. It can be observed from Table 3 that the E. coli population from the RF inoculum was able to grow even when the microcosm was saline and supplemented with only 0.1% Brain Heart Infusion (BHI) broth.

Table 3.

Comparison of cultivable coliforms (most probable number 100 mL−1) obtained in reverse filtration (RF) after 24 h of incubation in the microcosm (dark conditions and 3.5% NaCl)

Sample 2 Conc. filtrate RF Concentration inoculum % BHI added 24-h microcosm Replicates
Total coliforms 1.8E+05 1.8E+03 0.1 8.2E+06 3
E. coli 8.3E+04 8.3E+02 0.1 2.6E+05 3

Purified E. coli obtained from reverse filtration for inoculation in microcosm decay assays presents appropriate concentrations and physiologic conditions, but does not require the cultivation of natural samples. In microbial source tracking (MST) approaches for water quality surveys, it is desirable to use samples with little chemical contaminants (frequently present on the raw water) that may constitute interferences in the analytical procedures. The proposed reverse filtration (RF) was shown to be a fast, easy, and practical procedure for the separation of bacteria from raw water. It can be processed in approximately 60 min, producing a leachate with natural wild bacteria that fulfill the needed requirements, but stripped of water contaminants from where it was collected.

The 99% reduction on cell count, when compared with the original sample, was associated with adsorption to abundant solids in the sewage, but this value can be significantly reduced when the procedure is applied to natural waters (instead of raw sewage, as in the present research). Despite this reduction in cell count, the leachate obtained from reverse filtration proved to be adequate for E. coli inoculation in microcosms, because the inoculum contained enough cells to repopulate the microcosm. Besides, the bacterial inoculum constituted only a small fraction of the microcosm volume, without adding solid materials to the experimental set, as measured turbidity was insignificant. Particles between 0.45 and 0.80 μm were retained in the membrane and were leached together with bacteria in 100 mL of phosphate water, explaining the low absorbance (at 660 nm). In this case, residues that could be ecotoxic to the bacteria were adsorbed in the membrane and were significantly diluted during the last step, with only a small portion reaching the final leachate. Moreover, a leachate volume corresponding to only 1% of microcosms was used to inoculate, a dilution factor of 100.

Finally, a comparison of the presented method with current procedures applied in the literature highlights their advantages and pitfalls. Table 4 summarizes the advantages of reverse filtration in relation to preparation procedures currently used for inoculation in microcosms or environmental molecular evaluations. Inoculation of raw sewage [2] or raw natural water [21] shows pitfalls like varying physiological state, contamination with chemicals and nutrients that modify bacterial reproduction. Cultured bacteria as applied in the works of Jozic et al. [5] and Eichmiller et al. [22] may not respond adequately to natural processes, because these organisms display small genetic variation.

Table 4.

Comparison of current preparation of samples for inoculation in microcosms or environmental molecular evaluations with reverse filtration (RF)

Type of study Procedures from the literature Negative aspects Advantages of reverse filtration
Inoculation of microcosm or mesocosm Inoculation with raw natural water or sewage [2, 21]

Bacteria have varying cellular and physiological states.

Various generations may be present in the same sample

Presence of chemical contaminants, excess nutrient, and solid materials

Age and physiological state of the cells remain homogeneous. Cells are viable and cultivable

Inoculation can be done with freshly sampled raw sewage with no cultivation, minimizing dissolved contaminants and nutrients

Inoculation with cultured bacteria [5, 22] Alteration of the genetic expression of bacteria.
Molecular analysis of natural waters quality Bioaugmentation (pre-enrichment) [23] Quantitative approach is invalidated.

No bioaugmentation is necessary, reducing time spent. A qualitative approach is possible.

Cells remain viable and can be quantified by PMA-qPCR.

Concentration of cells can be carried out together with purification, reducing dissolved contaminants and minimizing damages to the genetic material to be extracted.

Cell concentration [23, 24] The procedure of cell concentration increases the amount of dissolved contaminants that damage genetic materials for PCR analyses
Nucleic acid extraction and purification [24, 25]. The nucleic acid extraction and purification result in the loss of molecular targets.

Although bioaugmentation [23] allows an increase in detection levels in molecular analyses for water quality evaluation, quantitative pieces of information are lost. On the other hand, cell concentration procedures [24] improve detection, but contaminants are also concentrated and may interfere with the results. Molecular analyses applying nucleic extractions also have been used to evaluate the resistance of bacteria under natural conditions [25]. However, the loss of molecular targets is expected.

Conclusion

The final leachate (from reverse filtration) contained viable and cultivable E. coli cells, in physiologically suitable conditions and quantity to produce inocula for microcosm tests. The results of the microcosm obtained after 24-h inoculation confirm this statement, when the inoculated population had grown approximately 310 times, although under unfavorable temperature, salinity, and nutritional conditions.

The results presented here allow to conclude that the leachate obtained by reverse filtration is also appropriate for microbial source tracking approaches, because contaminants in the sample were stripped off, while yielding cell concentrations compatible with what is usually required for this kind of studies. Furthermore, the obtained cells were shown viable and the leachate can be submitted to quantitative analyses of PMA-qPCR [26].

From the presented procedure, there is no need for culturing samples to obtain cells for inoculum, nor for augmenting the number of cells for molecular biochemistry surveys. The possibilities of alterations in genotypic expression—a frequent pitfall during cultures, such as those that occur in the transition from the log phase to the stationary phase—are reduced. Further studies are needed, mainly related to the chemical composition of the final leachate and the genetic expressions of the produced bacteria.

Acknowledgments

The authors are thankful to Fundação Instituto Osvaldo Cruz and Post-Graduation Program in the Management of Sustainable Systems of the University Federal Fluminense for their support.

Funding

This work was supported by the Brazilian Council of Scientific and Technological Development – CNPq (grant number 306714/2013-2) to JCW.

Compliance with ethical standards

Conflict of interest

The authors declare that there are no conflicts of interest.

Footnotes

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.Field KG, Samadpour M. Fecal source tracking, the indicator paradigm, and managing water quality. Wat Res. 2007;41(16):3517–3538. doi: 10.1016/j.watres.2007.06.056. [DOI] [PubMed] [Google Scholar]
  • 2.Mattioli MC, Sassoubre LM, Russell TL, Boehm AB. Decay of sewage-sourced microbial source tracking markers and fecal indicator bacteria in marine waters. Wat Res. 2017;108:106–114. doi: 10.1016/j.watres.2016.10.066. [DOI] [PubMed] [Google Scholar]
  • 3.Mendes Silva D, Domingues L. On the track for an efficient detection of Escherichia coli in water: a review on PCR-based methods. Ecotoxicol Environ Saf. 2015;113:400–411. doi: 10.1016/j.ecoenv.2014.12.015. [DOI] [PubMed] [Google Scholar]
  • 4.Berney M, Weilenmann HU, Ihssen J, Bassin C, Egli T. Specific growth rate determines the sensitivity of Escherichia coli to thermal, UVA, and solar disinfection. Appl Environ Microbiol. 2006;72(4):2586–2593. doi: 10.1128/AEM.72.4.2586-2593.2006. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Jozic S, Morovic M, Solic M, Krstulovic N, Ordulj M. Effect of solar radiation, temperature and salinity on the survival of two different strains of Escherichia coli. Fresenius Environ Bull. 2014;23(8):1852–1859. [Google Scholar]
  • 6.Siegele DA, Kolter R. Life after log. J Bacteriol. 1992;174(2):345–348. doi: 10.1128/jb.174.2.345-348.1992. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Pinto D, Santos MA, Chambel L. Thirty years of viable but nonculturable state research: unsolved molecular mechanisms. Crit Rev Microbiol. 2015;41(1):61–76. doi: 10.3109/1040841x.2013.794127. [DOI] [PubMed] [Google Scholar]
  • 8.Servais P, Prats J, Passerat J, Garcia-Armisen T. Abundance of culturable versus viable Escherichia coli in freshwater. Can J Microbiol. 2009;55(7):905–909. doi: 10.1139/w09-043. [DOI] [PubMed] [Google Scholar]
  • 9.Troussellier M, Bonnefont JL, Courties C, Derrien A, Dupray E, Gauthier M, Gourmelon M, Joux F, Lebaron P, Martin Y, Pommepuy M. Responses of enteric bacteria to environmental stresses in seawater. Oceanol Acta. 1998;21(6):965–981. doi: 10.1016/s0399-1784(99)80019-x. [DOI] [Google Scholar]
  • 10.Jang J, Hur HG, Sadowsky MJ, Byappanahalli MN, Yan T, Ishii S. Environmental Escherichia coli: ecology and public health implications a review. J Appl Microbiol. 2017;123(3):570–581. doi: 10.1111/jam.13468. [DOI] [PubMed] [Google Scholar]
  • 11.van Elsas JD, Semenov AV, Costa R, Trevors JT. Survival of Escherichia coli in the environment: fundamental and public health aspects. ISME J. 2011;5(2):173–183. doi: 10.1038/ismej.2010.80. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.McLellan SL, Huse SM, Mueller-Spitz SR, Andreishcheva EN, Sogin ML. Diversity and population structure of sewage-derived microorganisms in wastewater treatment plant influent. Environ Microbiol. 2010;12(2):378–392. doi: 10.1111/j.1462-2920.2009.02075.x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Bucci V, Vulic M, Ruan XD, Hellweger FL. Population dynamics of Escherichia coli in surface water. J Am Water Resour Assoc. 2011;47(3):611–619. doi: 10.1111/J.1752-1688.2011.00528.X. [DOI] [Google Scholar]
  • 14.Carrillo M, Estrada E, Hazen TC. Survival and enumeration of the fecal indicators Bifidobacterium adolescentis and Escherichia coli in atropical rain forest watershed. Appl Environ Microbiol. 1985;50(2):468–476. doi: 10.1128/AEM.50.2.468-476.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Hernroth B, Lothigius A, Bolin I. Factors influencing survival of enterotoxigenic Escherichia coli, Salmonella enterica (serovar Typhimurium) and Vibrio parahaemolyticus in marine environments. FEMS Microbiol Ecol. 2010;71(2):272–280. doi: 10.1111/j.1574-6941.2009.00803.x. [DOI] [PubMed] [Google Scholar]
  • 16.Ahmed W, Hughes B, Harwood VJ. Current status of marker genes of bacteroides and related taxa for identifying sewage pollution in environmental waters. Water. 2016;8(6):27. doi: 10.3390/w8060231. [DOI] [Google Scholar]
  • 17.Nocker A, Cheung C-Y, Camper AK. Comparison of propidium monoazide with ethidium monoazide for differentiation of live vs. dead bacteria by selective removal of DNA from dead cells. J Microbiol Methods. 2006;67(2):310–320. doi: 10.1016/j.mimet.2006.04.015. [DOI] [PubMed] [Google Scholar]
  • 18.Justice SS, Harrison A, Becknell B, Mason KM. Bacterial differentiation, development, and disease: mechanisms for survival. FEMS Microbiol Lett. 2014;360(1):1–8. doi: 10.1111/1574-6968.12602. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Herath G, Yamamoto K, Urase T. Mechanism of bacterial and viral transport through microfiltration membranes. Water Sci Technol. 1998;38(4–5):489–496. doi: 10.1016/s0273-1223(98)00549-6. [DOI] [Google Scholar]
  • 20.APHA (2012) Standard methods for the examination of water and wastewater. 22 edn. American Public Health Association; American Water Works Association; Water Environment Federation, Washington, DC
  • 21.Korajkic A, McMinn BR, Shanks OC, Sivaganesan M, Fout GS, Ashbolt NJ. Biotic interactions and sunlight affect persistence of fecal indicator bacteria and microbial source tracking genetic markers in the upper Mississippi River. Appl Environ Microbiol. 2014;80(13):3952–3961. doi: 10.1128/aem.00388-14. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Eichmiller JJ, Borchert AJ, Sadowsky MJ, Hicks RE. Decay of genetic markers for fecal bacterial indicators and pathogens in sand from Lake Superior. Water Res. 2014;59:99–111. doi: 10.1016/j.watres.2014.04.005. [DOI] [PubMed] [Google Scholar]
  • 23.Mull B, Hill VR. Recovery and detection of Escherichia coli O157:H7 in surface water, using ultrafiltration and real-time PCR. Appl Environ Microbiol. 2009;75(11):3593–3597. doi: 10.1128/aem.02750-08. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Maheux AF, Bissonnette L, Boissinot M, Bernier J-LT, Huppé V, Picard FJ, Bérubé È, Bergeron MG. Rapid concentration and molecular enrichment approach for sensitive detection of Escherichia coli and Shigella species in potable water samples. Appl Environ Microbiol. 2011;77(17):6199–6207. doi: 10.1128/aem.02337-10. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Zhang Q, He X, Yan T. Differential decay of wastewater bacteria and change of microbial communities in beach sand and seawater microcosms. Environ Sci Technol. 2015;49(14):8531–8540. doi: 10.1021/acs.est.5b01879. [DOI] [PubMed] [Google Scholar]
  • 26.Li D, Tong T, Zeng S, Lin Y, Wu S, He M. Quantification of viable bacteria in wastewater treatment plants by using propidium monoazide combined with quantitative PCR (PMA-qPCR) J Environ Sci. 2014;26(2):299–306. doi: 10.1016/S1001-0742(13)60425-8. [DOI] [PubMed] [Google Scholar]

Articles from Brazilian Journal of Microbiology are provided here courtesy of Brazilian Society of Microbiology

RESOURCES