Abstract
In this paper, we characterized an assortment of photopolymers and stereolithography processes to produce 3D-printed molds and polydimethylsiloxane (PDMS) castings of micromixing devices. Once materials and processes were screened, the validation of the soft tooling approach in microfluidic devices was carried out through a case study. An asymmetric split-and-recombine device with different cross-sections was manufactured and tested under different regime conditions (10 < Re < 70). Mixing performances between 3% and 96% were obtained depending on the flow regime and the pitch-to-depth ratio. The study shows that 3D-printed soft tooling can provide other benefits such as multiple cross-sections and other potential layouts on a single mold.
Keywords: micromixers, split-and-recombine, additive manufacturing, surface metrology, asymmetric split-and-recombine (ASAR), stereolithography, surface roughness, soft tooling
1. Introduction
Microfluidic-based devices tend to operate under laminar flow regimes where reagent mixing is a significant challenge [1]. Bringing together two separate fluid streams from opposite directions [2] is a strategy that researchers have employed to enhance mixing in a group of devices identified as Split and Recombine (SAR). While the simplest type of SAR device, constituted by a system where two streams collide downstream (T-mixer), has limited performance, further configurations of this principle have been implemented successfully with more intricate geometries, such as rhomboids [3,4], right angles [5,6,7], and arcs [8,9,10,11], as well as the introduction of pillars [12]. Most SAR micromixer devices have been fabricated using approaches such as (a) soft lithography plus polydimethylsiloxane (PDMS) casting, (b) micromachining, or (c) laser ablation.
The development of micromixing has made great strides toward improved designs with better performance and functionality. Hence, SAR micromixers have evolved to adopt more complex three-dimensional structures that include ridges and modular designs [13,14,15,16]. For example, Chen et al. used an array of triangular baffles with three depths to produce transverse movement of fluids toward a cascaded splitting and combination (C-SAR) [17], while Gidde et al. introduced a new design based on rectangular baffles, triple split and recombination (RB-TSAR), and elliptical-based triple split and recombination (EB-TSAR) [18]. Raza and Kim [19] proposed an improved asymmetric split and recombine design based on semi-circular profiles [20] by adding forward and backward-facing steps along the microchannel. They report mixing capabilities of 86% under Reynolds number (Re) below 20.
Recent developments include micromixers based on stacking and folding channels, showing a mixing efficiency beyond 95% [21], as well as good performance under a wide range of Reynolds number (0.5 < Re < 100) for Newtonian and non-Newtonian fluids [22]. These complex designs are fabricated via micromilling [21,22,23]. Other advanced micromixers are based on serpentines with non-rectangular cross-sections [24,25].
The toolkit of materials and manufacturing technologies available for microdevice designers has expanded significantly using additive manufacturing [26,27,28]. For example, Shallan et al. [29] manufactured a three-dimensional micromixer design through direct 3D printing. The concept is based on a 10× scaled-up version (500 µm) of a three-dimensional mixer based on the Baker Map on a theoretical work developed by Carriere [30]. The design is a paragon of the ideal micromixer device. It represents a three-dimensional projection of the split and recombine concept within all the Cartesian directions and mixing at perpendicular angles. Nonetheless, direct device manufacturing (one-step) is still challenging due to the difficulty of 3D printing internal channels [31].
The rapid or soft tooling approach, initially developed for a low-volume production environment, is a viable alternative when complex microdevices are required [32]. Depending on the application, additive manufacturing can be applied directly or indirectly to build tooling (molds). With a direct tooling approach, a mold or die is created directly through 3D printing [33,34]. Complex micromixers with convoluted features can provide an improved homogeneity of samples and tackle the limitations of the low Reynolds number regime [35].
Stereolithography (SLA) or vat photopolymerization comprises several additive manufacturing processes that rely on the selective curing of resin using a UV light. SLA can provide the UV light through several methods, including a laser, a digital micromirror device (DMD), or a combination of a lamp and alLiquid Crystal Display (LCD) based mask. Compared to most 3D printing processes, SLA provides fine resolution, in a range sufficient to reproduce the designs of intricate three-dimensional micromixers. While SLA brings a wide range of possibilities in the development of novel microfluidic devices [36], the available literature is limited in terms of testing and validation of process capability and reliability.
In the past, our group has shown the potential of soft tooling [37]. The objective of this study is to characterize a wider range of photopolymers and associated stereolithography processes in the context of good manufacturing practices for the development of micromixing devices. Surface and dimensional metrology were carried out for soft tooling (molds) in order to assess the process capability and potential chemical interaction with the cast PDMS. Once the photopolymers and SLA processes were screened, an asymmetric split-and-recombine (ASAR) device was built as a case study.
2. Materials and Methods
2.1. Soft Tooling Material Process Screening
Figure 1 describes the process to develop micromixing devices with complex features followed in this work. The design of molds of microdevices that feature a varying cross-section is introduced toward developing complex devices that are more prone to be adapted in-field. The new design introduces the capability to cast devices with multiple cross-sections on a single step toward developing complex devices that are more prone to be adapted in-field. The steps aim to examine an assortment of materials in three different types of stereolithography-based additive manufacturing processes. The materials were selected considering that the employment of resins had become an affordable benchtop technology available for microdevice designers in their lab or as a service [38,39,40,41]. Each material’s screening is performed with surface characterization and dimensional metrology of selected features and evaluating the usability and the potential to produce functional devices. Insights of the screening can then be applied for the soft tooling of improved devices.
2.1.1. Screening Mold Geometry
A mold with three main channels and protrusions was designed for material screening (see Figure 2). A depth of 5 mm was selected for the main chamber. Each mold is patterned with three main channels (WA = 9 mm, WB = 7 mm, and WC = 5 mm) and a singular depth or pitch (∆ = 2 mm).
2.1.2. Qualitative Assessment
The assortment of materials and additive manufacturing techniques were tested experimentally as soft tooling alternatives with the conditions shown below. The test consisted of employing simple manual tools including tweezers, an X-Acto knife, and a Silhouette toolkit that included a hook and a scraper (Silhouette America, West Orem, UT, USA). Once each mold was developed, observations were made to record the usability of the device compared with an aluminum device. The examination of each process included evaluating the difficulty of removing the PDMS elastomer from the device and reviewing the existence of any abnormality observed in the molded pattern after the curation process.
2.1.3. Screening Mold Metrology
For the characterization of the molds, an Alicona Infinite Focus Measurement Machine (Bruker Alicona Headquarters, Graz, Austria) was selected. This device allows for the acquisition of datasets at a high depth of focus, similar to a Scanning Electronic MicroscopeSurface roughness (Ra), measured using a 10x optical lens.
2.1.4. Aluminum Mold Manufactured Using a Conventional Subtractive Methodology
A mold was manufactured with conventional subtractive methodology using an aluminum alloy and a 3-axis vertical milling machine center Makino F3 (Makino Inc., MASON, OH, USA) with a maximum spindle speed of 30,000 RPM. A tool holder and a clamp were used for holding the workpiece. A laser measuring system by BLUM (Blum-Novotest Ltd., Staffordshire, UK) was used for tool setting. Three solid tungsten carbide cutting tools were used; a 12.7 mm diameter flat end mill with 4 flutes, a 5 mm diameter flat end mill with two flutes, and a 3 mm flat end- mill with 2 flutes were used for rough, semi-finish, and finish operation. Given the close tolerances achievable through machining, this mold was used as a reference base line.
2.2. Additive Manufacturing Processes and Materials
A professional laboratory equipment DLP-SLA Envisiontec Perfactory P3 Mini Multilens, that uses a 60 mm lens system, a work tray of 84 × 63 × 230 mm, and a layer resolution between 15 µm and 150 µm was employed to generate the molds using ABS Flex White, HTM 140, E-Dent 400, ABS Flex Black, and E-Partial. These materials were post-processed in an Otoflash pulse curing chamber of the same supplier (11 W lamp with a wavelength between 300 and 700 nanometers and ten pulses per second).
A benchtop SLA-LF Form 3 additive manufacturing equipment from Formlabs was used employing a 25 µm for the Clear V04 and 50 µm resolution setting for the Flexible V02 resin. Samples were cured using the provider’s recommended settings for post-processing the sample accordingly (15 min at 60 °C and 1 h of exposure to UV light).
Additionally, a 3D Systems ProJet 6000 that works with an ultraviolet laser was employed by a service provider [42] to develop devices in Accura SL 5530 resin. The thermoset resin selected for the molds was a high-temperature resistant stereolithography material, Accura SL 5530 (3D Systems, Rock Hill, SC, USA). A post-curing process was performed to the mold by exposing it for 90 min to UV light and baking it at a temperature of 160 °C for 2 h.
2.3. Microdevice Polydimethylsiloxane (PDMS) Casting
The standard process for PDMS casting was followed in this work. First, the Sylgard 184 PDMS (Dow-Corning, Midland, Michigan) was poured into a vessel and mixed with a curing agent in a 10:1 ratio by weight. To control this ratio the material was weighed using a calibrated analytical balance (Mettler AT200, Columbus, OH, USA). Then, the mixture was exposed to a vacuum chamber for 10 min to eliminate most of the air bubbles produced before and after pouring the material into the mold. Finally, each mold was placed over a hot plate at 75 °C for polymerization. The temperature was set below the glass transition temperature overnight (12 h) for the process screening and 45 min for the case study. In the latter, shorter times were considered to recreate a more lifelike and time demanding application. For other materials or experimental setup, different times might be required. The PDMS parts were removed using manual tools such as a cutting knife and tweezers.
For the case study, the inlets and outlet ports were punched using a 1.25 mm (internal diameter) Miltex disposable biopsy plunger (Integra Life Sciences, Princeton, NJ, USA). Then, the part was bonded to a 76 × 52 × 2 mm glass slide (VWR International, Radnor, PA, USA). Once the glass slide was cleaned with water and ethanol, the parts were introduced into a plasma cleaner (Harrick Plasma Inc., Ithaca, NY, USA). A vacuum inside the chamber was created for 3 min and the parts were exposed to plasma for 3 min. After three (3) more minutes, the treated surfaces were put in contact for PDMS-glass bonding. A visual inspection of the device was carried out to verify that the device was properly bonding and without bubbles trapped inside.
2.4. Case study: ASAR Micromixer Array
2.4.1. Micromixing Mold Geometry
The mixing performance of the proposed microdevice is based on the one developed by Ansari et al. [17] and used by our research group in the past [43,44]. This version has the added complexity of a variable depth or pitch ∆ (see Table 1 and Figure 3a). The device is composed of a single channel of 1000µm that splits into two subchannels of uneven width and converges on a channel six times (see Figure 3b,c). A set of micromixer molds were manufactured using the parameters described in Section 2.1 for ABS Flex White Resin. Additional molds were manufactured using ABS Flex Black and Accura SL 5530 resins.
Table 1.
Device Type | Array Elements | Microchannel Width (W) | SAR Subchannels (W1/W2) |
Micromixer Pitch ∆ |
---|---|---|---|---|
Asymmetric split and recombine micromixer | 6 | 1000 µm | 667/333 µm | I = 100 µm, II = 250 µm, III = 500 µm, IV = 750 µm, V = 900 µm, VI = 1000 µm |
2.4.2. Micromixing Performance Evaluation
Reynolds number is conventionally used to characterize the behavior of the flow conditions within microdevices and is defined as the ratio of inertial to viscous forces. Equation (1) represents the Reynolds number (Re) defined as:
(1) |
where µ is the viscosity (Pa s), ρ is the fluid density (kg m−3), U is the average velocity of the flow (m s−1), and Dh is the hydraulic diameter of channel (m), which is defined in Equation (2) as:
(2) |
where A and P are the area and the wetted perimeter of the cross-section, which is given by the micromixer width (W) and depth (∆).
To quantify the mixing behavior, the variance of the liquid species in the micromixer (σ) was calculated. The variance of the species was determined at the cross-sectional area at the output of the micromixer perpendicular to the x-axis. To evaluate the degree of mixing, the variance of the mass fraction of the mixture in a cross-section (σ) that is normal to the flow defined in Equation (3):
(3) |
where N is the number of sampling points inside the cross-section, ci is the mass fraction at the sampling point I, and cm is the optimal mixing mass fraction, which is 0.5 at any cross-sectional plane (ideal mixing). To quantitatively analyze the numerical mixing performance of the micromixer, the mixing index (M) at a cross-sectional plane is shown in Equation (4), which can be defined as:
(4) |
where the mixing efficiency (ranges from 0.00 (0% mixing) to 1.00 (100% mixing). The maximum variance σmax represents a completely unmixed condition.
2.4.3. Micromixing Experimental Setup
An experimental setup for testing mixing efficiency was used for micromixing evaluation. Inlet flows were programmed in a syringe pump (KDS200, Holliston, MA, USA). The micromixer device was evaluated on a range of conditions using the blue dye and distillate water under an Axiovert 200 inverted microscope (Carl Zeiss AG, Oberkochen, Germany). The mixing measures were calculated using intensity profiles. The image processing was performed using the custom software MIQUOD (Mixing Quantification of Devices). The actual flow entering the channels varied considering the hydraulic radius of each of the microchannels, and the Reynolds number at which the micromixer was tested was calculated using the FS3 and FS5 flow meters (Elvesys, Paris, France) connected to the MFS flow reader (Elvesys, Paris, France). The acquisition of 1920 × 1080 pixels images was made using a C930E webcam (Logitech Incorporated, Newark, CA, USA).
The ASAR micromixer array with a variable depth was developed using an Accura SL 5530 resin and tested to assess how relevant the channel pitch for determining the mixing performance. The target areas were equally defined for all the measures (193 × 197 pixels) and calibrated with a channel completely filled with dye and with water before experimentation. The calibration was carried out under the same operating conditions in the experiment (micromixer position and lighting).
3. Results
3.1. Qualitative Assessment of Screened Materials
The qualitative observations derived from the testing of materials for 3D printed mold are shown in Table 2. All the molds were tested under similar conditions. From the assessment it was observed that only the aluminum, E-Partial, ABS Flex white, Clear V04, and Flexible V02 showed the potential for the development of microfluidic devices. In contrast, E-Dent 400, ABS Flex Black, and HTM140 are not recommended for the development of molds. Difficulties for the remotion and swelling have been reported before for untreated bulk and surface of PDMS due to incompatibility with solvents, the absorption of small molecules, or deformations during casting [45,46,47]. It is possible that these could be some fundamental reasons for the negative observations registered.
Table 2.
Material | Manufacturing | Tensile Strength/Modulus (MPa) 1 | Observations during Casting |
---|---|---|---|
Aluminum 7075 | Micromilling | 276/ 68900 | Excellent surface quality, easy demolding |
Clear V04 | SLA-LF | 65/2800 | Excellent surface quality, excellent demolding |
Accura SL 5530 | SLA | 57-63/2854-3130 | Good surface quality |
E-Partial | SLA-DLP | 129/3125 | Good surface quality |
ABS Flex White | SLA-DLP | 65/1772 | Good surface quality |
Flexible V02 | SLA-LF | 3.4/8.5 | Fair surface quality, easy demolding due flexibility |
* E-Dent 400 | SLA-DLP | 85/2100 | Difficulties for demolding |
* ABS Flex Black | SLA-DLP | 65/1772 | Difficulties for demolding |
* HTM 140 | SLA-DLP | 115/3350 | PDMS reaction |
1 Information from datasheets. * Note: these resins are not recommended.
PDMS is a kind of silicone. The curing of silicones can be inhibited when in contact with materials that contains sulfur, tin, and nitrogen [48]. In the case of HTM 140, E-Dent 400, and ABS Flex Black, a partial or significant PDMS curing inhibition was found. Therefore, these materials are not recommended as molds. While ABS Flex White resin and ABS Flex Black share the same mechanical properties, it is suspected that the pigment on the latter inhibited PDMS curing. Unfortunately, vendors of 3D printing materials as the ones used in this study do not provide details on the chemical composition and additives. Therefore, it is difficult to provide a detailed analysis as to the reasons behind curing inhibition problems. In addition to the adverse effect of PDMS curing inhibition, the printed mold flexibility plays a significant role in the demanding process of the cast PDMS, as indicated in Table 2, that ranks mold materials from best to worst.
Once this initial qualitative screening was conducted, Clear V04 and Accura SL 5530 were used to produce cast PDMS components. With both of these materials, the plasma treatment was successful when sealing the PDMS component to the microscope slide.
Figure 4a shows a picture of some of the molds manufactured. The materials that are listed with difficulties for demolding either presented bad surface quality or the part could not be removed (See Figure 4b). This problem was most frequently observed between channels B and C and between channel C and the edge of the device, considering that these were the narrowest features.
Compared to the aluminum mold, the polymeric devices were prone to breaking due the force induced by the manual tools. For example, while the Accura SL 5530 resin mold produced a patterned part, one of the walls was shattered during the extraction.
In contrast, compelling results on the usability of the flexible material (Flexible v02) resin were found as the patterned piece could be pulled easily without apparent risks of destroying the device.
3.2. Dimensional and Surface Metrology of Photopolymers and AM Processes
Infinite Focus Microscopy (IFM) has been shown to be capable of capturing images with a lateral resolution down to 400 nm providing 3D data sets with very accurate results [49]. Table 3 and Table 4 resume the dimensional and surface metrology of the prismatic protrusions and main channels.
Table 3.
Feature | Feature | Al | ABS Flex White | HTM 140 | E-Dent 400 | ABS Flex Black | Accura SL 5530 | Clear V04 | Flexible V02 |
---|---|---|---|---|---|---|---|---|---|
PD (mm) | Protrusion depth | 1.006 ± 0.002 | 1.014 ± 0.013 | 1.026 ± 0.003 | 0.943 ± 0.002 | 1.011 ± 0.009 | 0.890 ± 0.013 | 1.006 ± 0.011 | 0.993 ± 0.011 |
PL (mm) | Protrusion length | 4.437 ± 0.002 | 4.207 ± 0.040 | 4.217 ± 0.052 | 4.512 ± 0.024 | 4.202 ± 0.019 | 4.450 ± 0.02 | 4.449 ± 0.041 | 4.504 ± 0.100 |
PW (mm) | Protrusion width | 3.036 ± 0.002 | 2.890 ± 0.013 | 2.887 ± 0.036 | 3.032 ± 0.012 | 2.908 ± 0.006 | 3.11 ± 0.056 | 3.02 ± 0.009 | 3.083 ± 0.010 |
Ra (µm) | Protrusion roughness | 0.262 ± 0.085 | 0.636 ± 0.002 | 0.526 ± 0.105 | 0.91 ± 0.170 | 0.394 ± 0.042 | 0.303 ± 0.036 | 0.807 ± 0.098 | 4.833 ± 0.164 |
Table 4.
Feature | Feature | Al | ABS Flex White | HTM 140 | E-Dent 400 | ABS Flex Black | Accura SL 5530 | Clear V04 | Flexible V02 |
---|---|---|---|---|---|---|---|---|---|
WA (mm) | Channel width A | 5.038 | 4.484 | 4.758 | 5.001 | 4.819 | 5.035 | 9.056 | 9.098 |
WB (mm) | Channel width B | 7.044 | 6.634 | 6.642 | 6.884 | 6.714 | 7.072 | 7.029 | 7.15 |
W C | Channel width C | 9.035 | 8.574 | 8.552 | 8.796 | 8.642 | 9.104 | 5.07 | 5.056 |
DABC (mm) | Channel depth | 1.996 ± 0.004 | 1.966 ± 0.015 | 2.004 ± 0.011 | 1.871 ± 0.008 | 1.954 ± 0.004 | 2.015 ± 0.005 | 2.009 ± 0.013 | 1.970 ± 0.010 |
Ra (µm) | Channel Roughness | 0.225 ± 0.066 | 0.653 ± 0.032 | 0.460 ± 0.056 | 1.095 ± 0.288 | 0.664 ± 0.120 | 0.354 ± 0.10 | 0.839 ± 0.043 | 4.871 ± 0.214 |
While the deviational error of the aluminum mold using subtractive manufacturing is still a paragon, there are some major advantages on the surface quality of the metallic device compared with the polymeric counterparts, however, such as low surface roughness and a significantly higher bulk modulus (easing the removal of the part from the mold). Low-force stereolithography printing uses a flexible tank and linear illumination to deliver and improve surface quality and print accuracy. According to the provider, lower print forces allow for support structures to be removed more easily (compared to traditional stereolithography) [50].
Figure 5 Clear V04 and Flexible V02 offered the closest (and lowest) deviational error to the aluminum molds among all the materials. The other materials had an absolute deviational error around between 2.97% and 3.64%. Additional data is available in the Supplementary Material.
In terms of the surface roughness of the devices, the values were very similar among the prismatic protrusions and the channels (see Table 3 and Table 4). The average surface roughness of each material is shown in Figure 6. The roughest surface was the Flexible v02, and the smoothest molds were produced with the Accura SL 5530 and the HTM 140 resins.
3.3. Case Study: Asymmetric Split-and-Recombine (ASAR) Microdevice Surface Metrology
An additional evaluation of features was done for some of the screened materials to evaluate if the features of a device with finer features could be produced and screened with a similar methodology as the molds made in Section 2.1.1.
Figure 7 shows examples that highlight the advantages of Infinite Focus for evaluating the features compared with other metrology options, such as a stylus-based profilometer. With this methodology, it is possible to obtain details in the micro and meso-scale concurrently in three-dimensional models and determine important functional features such as the width of the subchannels of the ASAR micromixer (Figure 7a).
Overall, the manufacture using the materials was consistent with the data described above. For example, the characterization of the set of ABS Flex White showed to be below 10 µm (see Figure 7b). Figure 7c shows an example of a device manufactured using the proposed methodology and employed for the micromixing performance manufactured with Accura SL 5530 (see Section 3.4). The material was selected because it displayed more potential for usability (see Table 2).
3.4. Micromixing Performance
Pictures obtained with the experimental setup described in Section 2.4.3 are shown in Figure 8a as examples of the varying conditions on the degree of mixing, depending on the Reynolds number and the pitch Δ. Figure 8b describes the mixing index (M) values quantitatively. As expected, a higher Reynolds number can be associated with a higher degree of mixing overall, considering that in conditions where the inertia forces are more predominant then the viscous forces, the chaotic advection can act to create secondary vortices and enhance mixing downstream.
The disposition of the array allowed us to evaluate the performance of the device under similar conditions for different depths and hence different width-to-height ratios (see Figure 8b). Notice that the color of the circle around the picture indicates the corresponding pitch (orange for 100 µm, green for 250 µm, purple for 500 µm, yellow for 750 µm, blue for 900 µm, and pink for 1000 µm). An examination of the data suggests that increasing the microchannel pitch can help increase the degree of mixing. However, the mixing performance improvement between the flow regime of Reynolds number 50 and Reynolds number 70 is limited. During the process, some bubbles were formed on some of the channels (Re = 70 and Δ = 250 µm); however, these appeared adjacently to the microdevice walls, and a disruption of the flow mixing due was not observed. The mixing performance showed a dependence on the pitch of the microchannel and the Reynolds number.
The capability to modify the mixing efficiency using a ratio of a single feature to the pitch of the channel has been reported previously [51,52]. Graph (Figure 8b) shows an upward trend between pitch and mixing efficiency. While the ASAR device was developed successfully, there are limitations that offer opportunities for further research to comprehend the phenomena underlying the operation.
3.5. Learned Lessons and Future Work
The applications of the learned lessons can be resumed in the case study as follows:
It is possible to produce different versions of the same device on a single mold with a single demolding step. Other possible layouts include different devices on a single molding step or an array of a single device.
Device identifier: engraving symbols on the device can be implemented for identifying the mold among different variations.
Other potential futures were prospected for future work, as removable wall(s) that could ease the remotion of the PDMS and the capability to dispose placeholders for inlet or outlet pins as part of the mold.
4. Conclusions
The concluding remarks of this work are summarized as follows:
The rapid or soft tooling approach was screened for eight (8) different photopolymers as a viable option for developing complex micromixing devices.
The experimental data provided valuable insights on acceptable manufacturing practices toward a new generation of devices.
The novel design of the mold with variable depth was successfully implemented to test different regime conditions within the same device.
Methodology for the production of an array of micromixers with a variable cross-section was successfully implemented.
Multiple cross-sections on a single device could be implemented using stereolithography. Other device setups (an array of a single device or different type of devices on a single mold) could be implemented using the methodology presented in this work.
Surface characterization showed an absolute deviational error within 10 micrometers.
Stereolithography is a viable option for the development of complex three-dimensional molds for the development of micromixers, but it is necessary to consider the surface-to-surface interaction between the mold and the resin.
Further studies are required to evaluate the effect of the geometrical features of the ASAR micromixer thoroughly.
Supplementary Materials
The following are available online at https://www.mdpi.com/2072-666X/11/11/970/s1, Supplementary file S1: Dimensional and surface metrology of materials for stereolithography-based AM processes.
Author Contributions
Conceptualization, J.I.M.-L., E.V. and E.A.N.; Data curation, L.D.C.I. and C.M.-B.; Formal analysis, H.A.B.C., L.D.C.I., A.M.L. and C.A.R.; Funding acquisition, J.I.M.-L., E.V., A.M.L., H.R.S, and C.A.R.; Investigation, H.A.B.C., L.D.C.I. and E.A.N.; Methodology, J.I.M.-L., E.V., H.R.S., and C.A.R.; Project administration, J.I.M.-L., E.V. and A.M.L.; Resources, E.V. and H.R.S.; Software, H.A.B.C.; Supervision, J.I.M.-L. and C.M.-B.; Validation, E.V., A.M.L., C.M.-B. and C.A.R.; Visualization, J.I.M.-L.; Writing—original draft, J.I.M.-L.; Writing—review & editing, J.I.M.-L., E.V., A.M.L. and C.A.R. All authors have read and agreed to the published version of the manuscript.
Funding
The CONACyT Basic Scientific Research Grant no. 242634 supported this work. The Research Group of Advanced Manufacturing provided additional support. The authors acknowledge the support from Centro de Investigación Numericalc for providing access to the Formlabs equipment and the technical support from Pavel Celis Retana.
Conflicts of Interest
The authors declare no conflict of interest.
Footnotes
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Gambhire S., Patel N., Gambhire G., Kale S. A Review on Different Micromixers and its Micromixing within Microchannel. Int. J. Curr. Eng. Technol. 2016;4 doi: 10.13140/RG.2.1.4235.4324. [DOI] [Google Scholar]
- 2.Su Y., Chen G., Yuan Q. Ideal micromixing performance in packed microchannels. Chem. Eng. Sci. 2011;66:2912–2919. doi: 10.1016/j.ces.2011.03.024. [DOI] [Google Scholar]
- 3.Chung C.K., Shih T.R. Effect of geometry on fluid mixing of the rhombic micromixers. Microfluid. Nanofluidics. 2008;4:419–425. doi: 10.1007/s10404-007-0197-9. [DOI] [Google Scholar]
- 4.Hossain S., Kim K.-Y. Mixing Analysis of Passive Micromixer with Unbalanced Three-Split Rhombic Sub-Channels. Micromachines. 2014;5:913–928. doi: 10.3390/mi5040913. [DOI] [Google Scholar]
- 5.Hong C.-C., Choi J.-W., Ahn C.H. A Novel In-Plane Passive Micromixer Using Coanda Effect. In: Ramsey J.M., van den Berg A., editors. Micro Total Analysis Systems 2001. Springer; Dordrecht, The Netherlands: 2001. pp. 31–33. [Google Scholar]
- 6.Hong C.-C., Choi J.-W., Ahn C.H. A novel in-plane passive microfluidic mixer with modified Tesla structures. Lab. Chip. 2004;4:109–113. doi: 10.1039/b305892a. [DOI] [PubMed] [Google Scholar]
- 7.Hossain S., Ansari M.A., Husain A., Kim K.-Y. Analysis and optimization of a micromixer with a modified Tesla structure. Chem. Eng. J. 2010;158:305–314. doi: 10.1016/j.cej.2010.02.002. [DOI] [Google Scholar]
- 8.Sudarsan A.P., Ugaz V.M. Fluid mixing in planar spiral microchannels. Lab. Chip. 2006;6:74–82. doi: 10.1039/B511524H. [DOI] [PubMed] [Google Scholar]
- 9.Ansari M.A., Kim K.-Y., Anwar K., Kim S.M. A novel passive micromixer based on unbalanced splits and collisions of fluid streams. J. Micromech. Microeng. 2010;20:055007. doi: 10.1088/0960-1317/20/5/055007. [DOI] [Google Scholar]
- 10.Ansari M.A., Kim K.-Y. Mixing performance of unbalanced split and recombine micomixers with circular and rhombic sub-channels. Chem. Eng. J. 2010;162:760–767. doi: 10.1016/j.cej.2010.05.068. [DOI] [Google Scholar]
- 11.Gidde R.R., Pawar P.M., Ronge B.P., Misal N.D., Kapurkar R.B., Parkhe A.K. Evaluation of the mixing performance in a planar passive micromixer with circular and square mixing chambers. Microsyst. Technol. 2018;24:2599–2610. doi: 10.1007/s00542-017-3686-0. [DOI] [Google Scholar]
- 12.Bazaz S.R., Warkiani M.E., Mehrizi A.A., Ghorbani S., Vasilescu S., Asadnia M. A hybrid micromixer with planar mixing units. RSC Adv. 2018 doi: 10.1039/C8RA05763J. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Nimafar M., Viktorov V., Martinelli M. Experimental comparative mixing performance of passive micromixers with H-shaped sub-channels. Chem. Eng. Sci. 2012;76:37–44. doi: 10.1016/j.ces.2012.03.036. [DOI] [Google Scholar]
- 14.Feng X., Ren Y., Jiang H. An effective splitting-and-recombination micromixer with self-rotated contact surface for wide {Reynolds} number range applications. Biomicrofluidics. 2013;7 doi: 10.1063/1.4827598. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.SadAbadi H., Packirisamy M., Wüthrich R. High performance cascaded PDMS micromixer based on split-and-recombination flows for lab-on-a-chip applications. RSC Adv. 2013;3:7296–7305. doi: 10.1039/c3ra40910d. [DOI] [Google Scholar]
- 16.Jian Chen J., Ren Lai Y., Tang Tsai R., Der Lin J., Yang Wu C. Crosswise ridge micromixers with split and recombination helical flows. Chem. Eng. Sci. 2011;66:2164–2176. doi: 10.1016/j.ces.2011.02.022. [DOI] [Google Scholar]
- 17.Chenouard N., Smal I., de Chaumont F., Maška M., Sbalzarini I.F., Gong Y., Cardinale J., Carthel C., Coraluppi S., Winter M., et al. Objective comparison of particle tracking methods. Nat. Methods. 2014;11:281–289. doi: 10.1038/nmeth.2808. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Gidde R.R., Pawar P.M. Flow feature and mixing performance analysis of {RB}-{TSAR} and {EB}-{TSAR} micromixers. Microsyst. Technol. 2020;26:517–530. doi: 10.1007/s00542-019-04498-w. [DOI] [Google Scholar]
- 19.Raza W., Kim K.-Y. Unbalanced Split and Recombine Micromixer with Three-Dimensional Steps. Ind. Eng. Chem. Res. 2020;59:3744–3756. doi: 10.1021/acs.iecr.9b00682. [DOI] [Google Scholar]
- 20.Li J., Xia G., Li Y. Numerical and experimental analyses of planar asymmetric split-and-recombine micromixer with dislocation sub-channels. J. Chem. Technol. Biotechnol. 2013;88:1757–1765. doi: 10.1002/jctb.4044. [DOI] [Google Scholar]
- 21.Chen X., Shen J. Numerical analysis of mixing behaviors of two types of {E}-shape micromixers. Int. J. Heat Mass Transf. 2017;106:593–600. doi: 10.1016/j.ijheatmasstransfer.2016.09.034. [DOI] [Google Scholar]
- 22.He M., Li W., Zhang M., Zhang J. Numerical investigation on the efficient mixing of overbridged split-and-recombine micromixer at low {Reynolds} number. Microsyst. Technol. 2019;25:3447–3461. doi: 10.1007/s00542-019-04317-2. [DOI] [Google Scholar]
- 23.Guckenberger D.J., De Groot T.E., Wan A.M.D., Beebe D.J., Young E.W.K. Micromilling: A method for ultra-rapid prototyping of plastic microfluidic devices. Lab. Chip. 2015 doi: 10.1039/C5LC00234F. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Clark J., Kaufman M., Fodor P.S. Mixing Enhancement in Serpentine Micromixers with a Non-Rectangular Cross-Section. Micromachines. 2018;9:107. doi: 10.3390/mi9030107. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Clark J.A., Butt T.A., Mahajan G., Kothapalli C.R., Kaufman M., Fodor P.S. Performance and implementation of centrifugal serpentine micromixers with non-rectangular cross-section. J. Micromechanics Microengineering. 2019;29:075012. doi: 10.1088/1361-6439/ab146c. [DOI] [Google Scholar]
- 26.Au A.K., Huynh W., Horowitz L.F., Folch A. {3D}-{Printed} {Microfluidics} Angew. Chemie Int. Ed. 2016;55:3862–3881. doi: 10.1002/anie.201504382. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Chen C., Mehl B.T., Munshi A.S., Townsend A.D., Spence D.M., Martin R.S. 3D-printed microfluidic devices: Fabrication, advantages and limitations—A mini review. Anal. Methods. 2016;8:6005–6012. doi: 10.1039/C6AY01671E. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Waheed S., Cabot J.M., Macdonald N.P., Lewis T., Guijt R.M., Paull B., Breadmore M.C. {3D} printed microfluidic devices: Enablers and barriers. Lab. Chip. 2016;16:1993–2013. doi: 10.1039/C6LC00284F. [DOI] [PubMed] [Google Scholar]
- 29.Shallan A.I., Smejkal P., Corban M., Guijt R.M., Breadmore M.C. Cost-effective three-dimensional printing of visibly transparent microchips within minutes. Anal. Chem. 2014;86:3124–3130. doi: 10.1021/ac4041857. [DOI] [PubMed] [Google Scholar]
- 30.Carrière P. On a three-dimensional implementation of the baker’s transformation. Phys. Fluids. 2007;19:118110. doi: 10.1063/1.2804959. [DOI] [Google Scholar]
- 31.Robles-Linares J., Ramírez-Cedillo E., Siller H., Rodríguez C., Martínez-López J., Robles-Linares J.A., Ramírez-Cedillo E., Siller H.R., Rodríguez C.A., Martínez-López J.I. Parametric Modeling of Biomimetic Cortical Bone Microstructure for Additive Manufacturing. Materials. 2019;12:913. doi: 10.3390/ma12060913. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Rajaguru J., Duke M., Au C.K. Development of rapid tooling by rapid prototyping technology and electroless nickel plating for low-volume production of plastic parts. Int. J. Adv. Manuf. Technol. 2015;78:31–40. doi: 10.1007/s00170-014-6619-4. [DOI] [Google Scholar]
- 33.Levy G.N., Schindel R., Kruth J.P. Rapid manufacturing and rapid tooling with layer manufacturing (LM) technologies, state of the art and future perspectives. CIRP Ann. 2003;52:589–609. doi: 10.1016/S0007-8506(07)60206-6. [DOI] [Google Scholar]
- 34.Udroiu R., Braga I.C. Polyjet Technology Applications for Rapid Tooling. Volume 112 EDP Sciences; Ulis, France: 2017. [Google Scholar]
- 35.Charmet J., Rodrigues R., Yildirim E., Challa P.K., Roberts B., Dallmann R., Whulanza Y. Low-Cost microfabrication tool box. Micromachines. 2020;11:135. doi: 10.3390/mi11020135. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Au A.K., Lee W., Folch A. Mail-order microfluidics: Evaluation of stereolithography for the production of microfluidic devices. Lab. Chip. 2014;14:1294–1301. doi: 10.1039/C3LC51360B. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Martínez-López J.I., Mendoza-Buenrostro C., Retana P.C., Betancourt H., Vazquez E., Siller H.R., Rodriguez C.A. Manufacturing and Test of Split and Recombine Micromixers with a Variable Cross-Section. ECS Meet. Abstr. 2018;MA2018-02:1303. doi: 10.1149/ma2018-02/39/1303. [DOI] [Google Scholar]
- 38.Vangunten M.T., Walker U.J., Do H.G., Knust K.N. 3D-Printed Microfluidics for Hands-On Undergraduate Laboratory Experiments. J. Chem. Educ. 2020;97:178–183. doi: 10.1021/acs.jchemed.9b00620. [DOI] [Google Scholar]
- 39.Nielsen J.B., Hanson R.L., Almughamsi H.M., Pang C., Fish T.R., Woolley A.T. Microfluidics: Innovations in materials and their fabrication and functionalization. Anal. Chem. 2020;92:150–168. doi: 10.1021/acs.analchem.9b04986. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Kotz F., Risch P., Helmer D., Rapp B.E. High-Performance Materials for 3D Printing in Chemical Synthesis Applications. Adv. Mater. 2019;31:1805982. doi: 10.1002/adma.201805982. [DOI] [PubMed] [Google Scholar]
- 41.Castiaux A.D., Pinger C.W., Hayter E.A., Bunn M.E., Martin R.S., Spence D.M. PolyJet 3D-Printed Enclosed Microfluidic Channels without Photocurable Supports. Anal. Chem. 2019 doi: 10.1021/acs.analchem.9b01302. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42.Protolabs Manufacturing [(accessed on 9 September 2020)]; Available online: http://www.protolabs.com.
- 43.Martínez-López J.I., Mojica M., Rodríguez C.A., Siller H.R. Xurography as a Rapid Fabrication Alternative for Point-of-Care Devices: Assessment of Passive Micromixers. Sensors. 2016;16:705. doi: 10.3390/s16050705. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44.Martínez-López J.I., Betancourt H.A., García-López E., Rodriguez C.A., Siller H.R. Rapid Fabrication of Disposable Micromixing Arrays Using Xurography and Laser Ablation. Micromachines. 2017;8:144. doi: 10.3390/mi8050144. [DOI] [Google Scholar]
- 45.Mukhopadhyay R. When PDMS isn’t the best. Anal. Chem. 2007;79:3249–3253. doi: 10.1021/ac071903e. [DOI] [PubMed] [Google Scholar]
- 46.Dangla R., Gallaire F., Baroud C.N. Microchannel deformations due to solvent-induced PDMS swelling. Lab. Chip. 2010;10:2972–2978. doi: 10.1039/c003504a. [DOI] [PubMed] [Google Scholar]
- 47.Wolf M.P., Salieb-Beugelaar G.B., Hunziker P. PDMS with designer functionalities—Properties, modifications strategies, and applications. Prog. Polym. Sci. 2018;83:97–134. doi: 10.1016/j.progpolymsci.2018.06.001. [DOI] [Google Scholar]
- 48.Leow M.E.L., Pho R.W.H. RTV silicone elastomers in hand prosthetics: Properties, applications and techniques. Prosthet. Orthot. Int. 1999;23:169–173. doi: 10.3109/03093649909071629. [DOI] [PubMed] [Google Scholar]
- 49.Schroettner H., Schmied M., Scherer S. Microchimica Acta. Volume 155. Springer; Berlin/Heidelberg, Germany: 2006. Comparison of 3D surface reconstruction data from certified depth standards obtained by SEM and an infinite focus measurement machine (IFM) pp. 279–284. [Google Scholar]
- 50.Formlabs Introducing the Form 3 and Form 3L. [(accessed on 2 October 2020)]; Available online: https://formlabs.com/blog/introducing-form-3-form-3l-low-force-stereolithography/
- 51.Hossain S., Afzal A., Kim K.Y. Shape Optimization of a Three-Dimensional Serpentine Split-and-Recombine Micromixer. Chem. Eng. Commun. 2017;204:548–556. doi: 10.1080/00986445.2017.1289185. [DOI] [Google Scholar]
- 52.Raza W., Hossain S., Kim K.Y. Effective mixing in a short serpentine split-and-recombination micromixer. Sensors Actuators B Chem. 2018;258:381–392. doi: 10.1016/j.snb.2017.11.135. [DOI] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.