Skip to main content
BMC Genomics logoLink to BMC Genomics
. 2020 Dec 4;21:863. doi: 10.1186/s12864-020-07283-6

A rapid, cost-effective tailed amplicon method for sequencing SARS-CoV-2

Daryl M Gohl 1,2,, John Garbe 1, Patrick Grady 1, Jerry Daniel 1, Ray H B Watson 1, Benjamin Auch 1, Andrew Nelson 3, Sophia Yohe 3, Kenneth B Beckman 1
PMCID: PMC7716288  PMID: 33276717

Abstract

Background

The global COVID-19 pandemic has led to an urgent need for scalable methods for clinical diagnostics and viral tracking. Next generation sequencing technologies have enabled large-scale genomic surveillance of SARS-CoV-2 as thousands of isolates are being sequenced around the world and deposited in public data repositories. A number of methods using both short- and long-read technologies are currently being applied for SARS-CoV-2 sequencing, including amplicon approaches, metagenomic methods, and sequence capture or enrichment methods. Given the small genome size, the ability to sequence SARS-CoV-2 at scale is limited by the cost and labor associated with making sequencing libraries.

Results

Here we describe a low-cost, streamlined, all amplicon-based method for sequencing SARS-CoV-2, which bypasses costly and time-consuming library preparation steps. We benchmark this tailed amplicon method against both the ARTIC amplicon protocol and sequence capture approaches and show that an optimized tailed amplicon approach achieves comparable amplicon balance, coverage metrics, and variant calls to the ARTIC v3 approach.

Conclusions

The tailed amplicon method we describe represents a cost-effective and highly scalable method for SARS-CoV-2 sequencing.

Keywords: COVID-19, SARS-CoV-2, Genome sequencing, Viral surveillance

Background

The global COVID-19 pandemic has necessitated a massive public health response which has included implementation of society-wide distancing measures to limit viral transmission, the rapid development of qRT-PCR, antigen, and antibody diagnostic tests, as well as a world-wide research effort of unprecedented scope and speed. Next generation sequencing technologies (NGS) have recently enabled large-scale genomic surveillance of infectious diseases. Sequencing-based genomic surveillance has been applied to both endemic disease, such as seasonal influenza [1], and to emerging disease outbreaks such as Zika and Ebola [24].

As of Novemeber 2020, over 225,000 SARS-CoV-2 genome sequences have been deposited in public repositories such as NCBI and GISAID [5, 6]. Several large-scale consortia in the UK (COG-UK: COVID-19 Genomics UK), Canada (CanCOGeN: Canadian COVID Genomics Network), and the United States (CDC SPHERES: SARS-CoV-2 Sequencing for Public Health Emergency Response, Epidemiology, and Surveillance) have begun coordinated efforts to sequence large numbers of SARS-CoV-2 genomes. Such genomic surveillance has already enabled insights into the origin and spread of SARS-CoV-2 [7, 8], including the sequencing efforts by the Seattle flu study which provided early evidence of extensive undetected community transmission of SARS-CoV-2 in the Seattle area [9].

A number of different approaches have been used to sequence SARS-CoV-2. Metagenomic (RNA) sequencing can be used to sequence and assemble the SARS-CoV-2 genome [10]. This approach has the disadvantage that samples must typically be sequenced very deeply in order to obtain sufficient coverage of the viral genome, and thus the cost of this approach is high relative to more targeted methods. Sequence capture methods (Fig. 1a) can be used to enrich for viral sequences in order to lower sequencing costs and are being employed to sequence SARS-CoV-2 [11]. Finally, amplicon approaches (Fig. 1b), in which cDNA is made from SARS-CoV-2 positive samples and amplified using primers that generate tiled PCR products are being used to sequence SARS-CoV-2 [3]. Since primers cannot capture the very ends of the viral genome, amplicon approaches have the drawback of slightly less complete genome coverage, and mutations in primer binding sites have the potential to disrupt the amplification of the associated amplicon [12]. However, the relatively low-cost of amplicon methods make them a good choice for population-scale viral surveillance and such approaches have recently been used successfully to monitor the spread of viruses such as Zika and Ebola [24].

Fig. 1.

Fig. 1

Methods for SARS-CoV-2 genome sequencing compared in this study. a In Illumina’s Nextera DNA Flex Enrichment protocol cDNA is tagmented and made into barcoded sequencing libraries, which are then enriched using sequence capture with a respiratory virus panel containing probes against SARS-CoV-2. b In the ARTIC protocol, first strand cDNA is enriched by amplifying with two pools of primers to generate amplicons tiling the SARS-CoV-2 genome. These amplicons are then subjected to either Illumina or Oxford Nanopore library preparation, using methods that either directly add adapters to the ends of the amplicons or to fragment them to enable sequencing on a wider variety of Illumina instruments. c The tailed amplicon approach, developed here, enriches first strand cDNA using ARTIC v3 primers containing adapter tails. This allows functional sequencing libraries to be created through a second indexing PCR reaction that adds sample-specific barcodes and flow cell adapters

The ARTIC network (https://artic.network/) has established a method for preparing amplicon pools in order to sequence SARS-CoV-2 (Fig. 1b). The ARTIC primer pools have gone through multiple iterations to improve evenness of coverage [13]. Several variants of the ARTIC protocol exist in which the pooled SARS-CoV-2 amplicons from a sample are taken through a NGS library preparation protocol (using either ligation or tagmentation-based approaches) in which sample-specific barcodes are added, and are then sequenced using either short-read (Illumina) or long-read (Oxford Nanopore, PacBio) technologies. The library preparation step currently represents a bottleneck in sequencing SARS-CoV-2 amplicons, in terms of both cost and labor.

Here we describe an all-amplicon method for producing SARS-CoV-2 sequencing libraries which simplifies the process and lowers the per sample cost for sequencing SARS-CoV-2 genomes (Fig. 1c). This approach incorporates adapter tails in the ARTIC v3 primer designs, allowing sequencing libraries to be produced in a two-step PCR process, bypassing costly and labor-intensive ligation or tagmentation-based library preparation steps. By re-optimizing the pooling strategy for the tailed primers, we demonstrate that this tailed amplicon approach can achieve similar coverage to the untailed ARTIC v3 primers at equivalent sequencing depths. We benchmark this approach against both the standard ARTIC v3 protocol and a sequence capture approach using clinical samples spanning a range of viral loads. The approach we describe is similar to a tailed-amplicon method that we have used to process more than 150,000 microbiome samples in recent years in the University of Minnesota Genomics Center [14], and thus represents a highly scalable method for sequencing large numbers of SARS-CoV-2 genomes in a rapid and cost-effective manner.

Results

We designed a series of experiments in order to test a streamlined tailed amplicon method and to compare amplicon and sequence capture based methods for SARS-CoV-2 sequencing (Fig. 1). We sequenced a set of samples using Illumina’s Nextera DNA Flex Enrichment protocol using a respiratory virus oligo panel containing probes for SARS-CoV-2, the ARTIC v3 tiled primers, and a novel tailed amplicon method designed to reduce cost and streamline the preparation of SARS-CoV-2 sequencing libraries.

We first evaluated the different SARS-CoV-2 sequencing workflows in their performance with a previously sequenced SARS-CoV-2 isolate strain from Washington state (2019-nCoV/USA-WA1/2020) provided by BEI Resources [15]. An estimated 10,000 viral genome copies were used as input for cDNA generation. As expected, since the amplicon approaches are unable to cover sequences at the ends of the SARS-CoV-2 genome, the DNA Flex Enrichment sequence capture method produced the highest genome coverage. At a subsampled read depth of 100,000 reads, the Nextera DNA Flex Enrichment method achieved 99.96% coverage at a minimum of 10x and 99.69% coverage at a minimum of 100x (Fig. 2a-b, Supplemental Tables 1–2). The ARTIC v3 library prepared with TruSeq library preparation achieved 99.60% coverage at a minimum of 10x and 97.31% coverage at a minimum of 100x (Fig. 2a-b, Supplemental Tables 1–2).

Fig. 2.

Fig. 2

Comparison of sequence capture, ARTIC v3 amplicon, and tailed amplicon workflows on SARS-CoV-2 isolate. a Percentage of the BEI WA1 isolate genome coverage at 10x at different subsampled read depths when sequenced with the indicated approach. b Percent of the BEI WA1 isolate genome coverage at 100x at different subsampled read depths when sequenced with the indicated approach. c Observed read depth for each of the expected amplicons for the BEI WA1 isolate amplified with the ARTIC v3 protocol at a subsampled read depth of 100,000 raw reads. d Observed read depth for each of the expected amplicons for the BEI WA1 isolate amplified with the tailed amplicon v1 (2 pool amplification) protocol at a subsampled read depth of 100,000 raw reads. e Observed read depth for each of the expected amplicons for the BEI WA1 isolate amplified with the tailed amplicon v2 protocol (4 pool amplification) at a subsampled read depth of 100,000 raw reads. f Variants detected for the BEI WA1 isolate at a read depth of up to 1,000,000 raw reads (or the maximum read depth for the sample if below 1,000,000 reads). The positions of all variants detected in this study are shown and bases where the sample matches the Wuhan-Hu-1 reference are shown in grey

We tested a tailed amplicon method (tailed amplicon v1) in which the tailed version of the ARTIC v3 primers were pooled into two pools in a similar manner to the ARTIC v3 protocol. The BEI WA1 isolate strain was amplified for both 25 or 35 PCR cycles, using the same enzymes and PCR conditions used for the ARTIC v3 data set. The tailed amplicon v1 method produced lower coverage than the ARTIC v3 method, with 98.87% coverage at a minimum of 10x and 89.40% coverage at a minimum of 100x for the 25 PCR cycle sample and 97.09% coverage at a minimum of 10x and 81.31% coverage at a minimum of 100x for the 35 PCR cycle sample (Fig. 2a-b, Supplemental Tables 1–4). The poorer performance with respect to coverage metrics with the tailed amplicon v1 protocol was due to substantially worse balance between the different tiled amplicons compared with the ARTIC v3 (untailed) primers (Fig. 2c-d). The coefficient of variation (CV) of the ARTIC v3 sample was 0.49 and the CVs of the tailed amplicon v1 samples were 1.70 and 1.26 for the 25 and 35 PCR cycle samples, respectively.

The ARTIC v3 primers have been through multiple cycles of iteration to achieve relatively even amplicon balance and genome coverage [13]. We reasoned that reducing the concentration of the primers that were over-represented in the initial round of sequencing may improve balance. While adjusting the primer concentration for over-represented amplicons did lower the CV of the tailed amplicon pool, amplicon balance was still substantially worse than with the untailed ARTIC v3 primers (data not shown).

We next tested whether splitting the tailed SARS-CoV-2 primers into 4 PCR reactions based on primer performance in the initial sequencing tests could improve balance with the tailed primer approach. The 4-pool amplification scheme (tailed amplicon v2) achieved coverage metrics close to the untailed ARTIC v3 approach at comparable read depths with 99.60% coverage at a minimum of 10x and 95.64% coverage at a minimum of 100x (Fig. 2a-b, Supplemental Table 1, Supplemental Table 2). The improvement in genome coverage metrics with the tailed amplicon v2 approach was a function of improved amplicon balance (Fig. 2e). The CV of the tailed amplicon v2 sample was 0.52 (comparable to the CV of 0.49 with the untailed ARTIC v3 approach). The same three variants were detected by all four methods tested (Fig. 2f), consistent with prior comparisons of the USA-WA1/2020 and the Wuhan-Hu-1 reference strain.

Next, we assessed the performance of the different SARS-CoV-2 sequencing approaches on a set of de-identified patient samples. We selected 9 SARS-CoV-2 positive patient samples spanning a range of viral loads as assessed by a qRT-PCR using the CDC primers targeting the SARS-CoV-2 nucleocapsid gene (N1 and N2 targets, Supplemental Fig. S1). In addition, we included two patient negative samples in these experiments. We carried out initial tests of the Nextera DNA Flex Enrichment protocol, the tailed amplicon v1 approach, and the ARTIC v3 approach using this sample set. In initial tests, samples with N1 and N2 Ct values greater than 35 yielded poor coverage (~ 50% genome coverage at 10x) using the tailed amplicon method, did not yield useful data for the Nextera DNA Flex Enrichment protocol, and did not generate enough amplicon template to proceed with library preparation for the ARTIC v3 method (data not shown). RNA from sample (UMGC-6) was completely consumed in initial testing and could not be compared across all methods. Thus, for testing the tailed amplicon v2 approach, and comparing among all four methods, we used a subset of these patient samples with N1 and N2 Ct values ranging from ~ 20–35 (Fig. 3a).

Fig. 3.

Fig. 3

Comparison of sequence capture, ARTIC v3 amplicon, and tailed amplicon workflows on clinical specimens spanning a range of viral loads. a Samples with N1 and N2 Ct values ranging from approximately 20–35 chosen for testing of SARS-CoV-2 sequencing workflows. Samples are colored as in panels c-f. b Evenness of representation of amplicons for different workflows as a function of sample N1 Ct value. Percentage of genome coverage at 100x at different subsampled read depths for each sample when sequenced using the following approaches: c Illumina Nextera DNA Enrichment; d ARTIC v3 with TruSeq library preparation. e Tailed amplicon v1 (2 pool amplification); f Tailed amplicon v2 (4 pool amplification)

For the Illumina DNA Flex Enrichment protocol, SARS-CoV-2 genome coverage was more complete for samples with lower N1 and N2 Cts (ranging from ~ 20–30) at comparable read depths and coverage thresholds than with amplicon approaches, similar to the BEI WA isolate data (Fig. 3c, Supplemental Fig. S2-S3). However, for samples with N1 and N2 Ct values greater than approximately 30, the number of sequencing reads were substantially reduced and the proportion of reads mapping to the human genome were substantially increased (Supplemental Fig. S4). The average coverage at a subsampled read depth of 100,000 raw reads was 99.89% (10x) and 75.90% (100x) for all six test samples (Supplemental Table 1, Supplemental Table 2). For samples with N1 and N2 Ct vales of less than 30, average coverage was 99.92% (10x) and 99.62% (100x) at a subsampled read depth of 100,000 raw reads (Supplemental Tables 1–2).

For ARTIC v3 tests, based on the N1 and N2 target Ct values from clinical testing, we used either 25, 30, or 35 PCR cycles for the amplification reactions. Sufficient amplification to carry out TruSeq library prep was seen for samples with Cts of around 35 or less. Five patient samples with N1 and N2 Ct values ranging from ~ 20–35 and the BEI WA isolate sample were selected for TruSeq library prep and sequencing; one sample (N1 Ct = 20, N2 Ct = 20.4) was prepared in triplicate. Consistent with previous descriptions of the ARTIC v3 primers, the balance between the tiled amplicons across these samples was relatively even, with a mean CV of 0.61 among the five patient samples tested, and 0.55 for samples with a N1 and N2 Ct of less than 30 (Fig. 3b, Supplemental Fig. S5). For the ARTIC v3 protocol, the average coverage at a subsampled read depth of 100,000 raw reads was 98.97% (10x) and 95.14% (100x) for all five test samples. For samples with N1 and N2 Ct vales of less than 30, average coverage was 98.99% (10x) and 96.45% (100x) at a subsampled read depth of 100,000 raw reads (Fig. 3d, Supplemental Fig. S2-S3, Supplemental Tables 1–2).

We performed initial tests of the tailed amplicon v1 protocol by amplifying the samples listed in Fig. 3a for 25 or 35 PCR cycles using tailed versions of the ARTIC v3 primers split into two separate pools. As with the BEI WA isolate sample, the balance observed with the tailed amplicon v1 approach was worse than the ARTIC v3 protocol, with a mean CV of 1.81 among the six patient samples tested, and 1.28 for samples with a N1 and N2 Ct of less than 30 (Fig. 3b, Supplemental Fig. S6, Supplemental Tables 1–4). This led to decreased coverage at a given read depth for the tailed amplicon v1 method relative to ARTIC v3 (Fig. 3e, Supplemental Fig. S2, Supplemental Tables 1–4).

Upon splitting the tailed SARS-CoV-2 primers into 4 PCR reactions based on primer performance in the initial sequencing tests, the tailed amplicon v2 method had much improved amplicon balance. The mean CV of all six patient samples was 0.76 (compared to a CV of 0.61 with ARTIC v3) and 0.52 for samples with a N1 and N2 Ct of less than 30 (compared to 0.55 with the ARTIC v3 protocol; Fig. 3b, Supplemental Fig. S7). The tailed amplicon v2 protocol had an average coverage at a subsampled read depth of 100,000 raw reads of 97.54% (10x) and 87.17% (100x) for all six test samples (Supplemental Tables 1–2). For samples with Ct vales of less than 30, average coverage was 98.81% (10x) and 94.72% (100x) at a subsampled read depth of 100,000 raw reads (Fig. 3f, Supplemental Fig. S2-S3, Supplemental Tables 1–2).

The slightly lower coverage metrics at a given subsampled read depth for the tailed amplicon v2 method can likely be explained by primer dimer formation during the two-step amplification process, which is more pronounced for higher N1 and N2 Ct samples (Supplemental Fig. S8). Despite observing negligible amounts of primer dimer products on the bioanalyzer trace, samples with N1 and N2 Ct values greater than 30 had as much as 50% primer dimer in the resulting sequencing reads. We have previously reported a substantial size bias on the MiSeq, which may help explain the preferential clustering and out-sized proportion of primer dimer reads present in the sequencing data for some samples [16]. While this issue can be overcome by increased sequencing depth, future optimizations aimed at reducing primer dimer contamination such as more stringent size selection or sequencing on an instrument with less size bias, such as the NovaSeq [16] could reduce this effect. Introduction of a bead clean-up step between the first and second PCRs can also help reduce the proportion of adapter dimers when using the tailed amplicon v2 protocol (Amy Kistler, personal communication).

Finally, we examined the variants detected in the patient samples for each of the SARS-CoV-2 sequencing methods. There was complete concordance in the variant calls for all samples with N1 and N2 Ct values below 30, but less agreement among variant calls between methods for the sample with N1 and N2 Ct values of approximately 35 (Fig. 4).

Fig. 4.

Fig. 4

Variants detected using different sequencing workflows. Variants detected for the indicated sample and sequencing protocol at a read depth of up to 1,000,000 raw reads (or the maximum read depth for the sample if below 1,000,000 reads). The positions of all variants detected in this study are shown and bases where the sample matches the Wuhan-Hu-1 reference shown in grey

Discussion

Here we compare sequence capture and amplicon-based methods for sequencing SARS-CoV-2 and describe a streamlined tailed amplicon method for cost-effective and highly scalable SARS-CoV-2 sequencing. In comparing the sequence capture and amplicon-based methods, there is a trade-off between the completeness of genome coverage and sensitivity (being able to analyze samples with higher N1 and N2 Ct values). Consistent with other recent analyses of SARS-CoV-2 amplicon sequencing approaches [17], we observed highly concordant results from samples with N1 and N2 Ct values of less than 30. For samples with Ct values between 30 and 35, coverage metrics tended to be less robust at a given read depth and samples with Ct values of greater than 35 did not perform well under any of the conditions tested. Based on validation experiments for the University of Minnesota qRT-PCR clinical COVID-19 diagnostic assay, we estimate that a Ct value of 30 corresponds to roughly 500 SARS-CoV-2 genome copies and a Ct value of 35 corresponds to roughly 15 SARS-CoV-2 genome copies in the 5 μL input used for cDNA creation [18].

We describe a modified workflow for SARS-CoV-2 sequencing which builds on the tiled amplicon approach developed by the ARTIC consortium and currently employed by many labs around the world. This tailed amplicon method uses a two-step PCR process similar to workflows previously described by us and others to generate microbiome or other amplicon sequencing data [14]. Through an iterative testing process, we demonstrate that with the tailed amplicon v2 method, a four-pool amplification scheme produces data with comparable amplicon balance, coverage metrics, and variant calls to the ARTIC v3 approach.

Conclusions

The tailed amplicon approach we describe bypasses costly and labor-intensive library preparation steps and will allow for production of SARS-CoV-2 libraries at high scale (similar workflows are run on tens of thousands of samples per year in the University of Minnesota Genomics Center) at low cost (between $20–40 per sample depending on scale, including labor costs). We anticipate that this approach will aid in the genomic surveillance of SARS-CoV-2 as well as studies on viral diversity and evolution, and the influence of virus genetics on transmissibility, virulence, and clinical outcomes.

Methods

Samples

Extracted RNA from de-identified clinical biospecimens were obtained subsequent to COVID-19 testing at the University of Minnesota for use under the IRB approved protocol “Detection of COVID 19 by Molecular Methods” (STUDY00009560). Nine samples spanning a range of viral loads as assessed by the Ct values of the viral N1 and N2 targets by qRT-PCR were selected for these studies. In addition, two SARS-CoV-2 negative samples were selected to assess cross-contamination or other sequencing artifacts. The following reagent was deposited by the Centers for Disease Control and Prevention and obtained through BEI Resources, NIAID, NIH: Genomic RNA from SARS-Related Coronavirus 2, Isolate USA-WA1/2020, NR-52285.

RNA extraction

RNA was extracted using one of three kits (Qiagen QIAamp Viral RNA Mini kit, Macherey-Nagel Nucelospin Virus Mini kit, and Biomérieux easyMag NucliSENS system) as described previously [18]. All extraction methods used 100 μL of viral transport medium as input and eluted in 100 μL of appropriate elution buffer as indicated by manufacturer protocols. The integrity of the extracted RNA was analyzed using the Agilent high sensitivity RNA screentape assay on Agilent 2200 TapeStation following the manufacturer’s guidelines (Agilent, Santa Clara, CA).

SARS-CoV-2 qRT-PCR

qRT-PCR reactions to identify SARS-CoV-2 positive samples were carried out using a modified version of the Centers for Disease Control and Prevention (CDC) SARS-CoV-2 qRT-PCR assay, as previously described [18]. Briefly, three separate 10 μL RT-qPCR reactions were set up in a 384-well Barcoded plate (Thermo Fisher Scientific, Waltham, MA) for either the N1, N2, or RP primers and probes. 2.5 μL extracted RNA was added to 7.5 μL qPCR master mix comprised of the following components: 1.55 μL nuclease-free water, 5 μL GoTaq® Probe qPCR Master Mix with dUTP (2X) (Promega, Madison, WI), 0.2 μL GoScript™ RT Mix for 1-Step RT-qPCR (Promega, Madison, WI), 0.75 μL primer/probe sets for either N1, N2, or RP (IDT, Coralville, IA). Reactions were run on a QuantStudio QS5 (Thermo Fisher Scientific, Waltham, MA) using the following cycling conditions: one cycle of 45 °C for 15 min, followed by one cycle of 95 °C for 2 min, followed by 45 cycles of 95 °C for 15 s and 60 °C for 1 min. A minimum of two no template controls (NTCs) were included on all runs. A ΔRn threshold of 0.5 was selected and set uniformly for all runs. Ct values were exported and analyzed in Microsoft Excel.

ARTIC v3 amplicon library generation and sequencing

The following reaction was set up to create cDNA using the ARTIC v3 protocol: 5 μL template RNA, 11 μL nuclease-free water, 4 μL SuperScript IV VILO master mix (Thermo Fisher Scientific, Waltham, MA). cDNA synthesis reactions were incubated at: 25 °C for 10 min, followed by 50 °C for 10 min and 85 °C for 5 min. cDNA was amplified using each of the two ARTIC v3 primer pools which tile the SARS-CoV-2 genome. The following recipe was used to set up the PCR reactions: 2.5 μL template cDNA, 14.75 μL nuclease-free water, 5 μl 5x Q5 reaction buffer (New England Biolabs, Ipswich, MA), 0.5 μL 10 mM dNTPs (Kapa Biosystems, Woburn, MA), 0.25 μL Q5 Polymerase (New England Biolabs, Ipswich, MA), 2 μL primer pool 1 or 2 (10 μM). Cycling conditions were: 98 °C for 30 s, followed by 25 or 35 cycles of 98 °C for 15 s and 65 °C for 5 min. Pools 1 and 2 were then combined, cleaned up with 1:1 AMPureXP beads (Beckman Coulter, Brea, CA)., and quantified by Qubit Fluorometer and Broad Range DNA assay (Thermo Fisher Scientific, Waltham, MA) and TapeStation capillary electrophoresis (Agilent, Santa Clara, CA).

Eight samples with > 1 ng/μL concentration of target amplicons were selected for downstream library preparation. Library preparation was performed following the standard Illumina TruSeq Nano DNA protocol for 350 base pair libraries (Illumina, San Diego, CA). A total of 100 ng of amplicons from the ARTIC protocol were used as the input for library preparation. Input material was not sheared, as the amplicons were already the desired fragment length.

Nextera DNA flex enrichment with respiratory virus panel

A modified non-directional NEBNext Ultra II First and Second Strand (#E7771 and #E6111, New England Biolabs, Ipswich, MA) protocol was used to generate long fragments of double-stranded cDNA as input material for the Nextera DNA Flex Enrichment with respiratory virus panel. The following reaction was set up for non-fragmented priming of RNA: 5 μL template RNA and 1 μL NEBNext Random Primers were combined and incubated at 65 °C for 5 min. Non-directional first strand cDNA synthesis was performed by combining 6 μl of primed template RNA, 4 μL NEBNext First Strand Synthesis Buffer, 2 μL NEBNext First Stand Synthesis Enzyme Mix, and 8 μL nuclease-free water. The first strand synthesis reaction was incubated at 25 °C for 10 min, 42 °C for 50 min, 70 °C for 15 min. Second strand cDNA synthesis was performed by combining 20 μl first strand synthesis product, 8 μL of NEBNext Second Strand Synthesis Reaction Buffer with dUTP mix (10X), 4 μL NEBNext Second Strand Synthesis Enzyme Mix, and 48 μL nuclease-free water. The second strand synthesis reaction was incubated at 16 °C for 60 min. Double-stranded cDNA was purified and concentrated with 1.8X AMPureXP beads (Beckman Coulter, Brea, CA) before eluting into 30 μL of 0.1X TE Buffer. Double-stranded cDNA size was determined using Bioanalyzer high sensitivity DNA assay (Agilent, Santa Clara, CA) and quantified with Qubit Fluorometer and High Sensitivity DNA assay (Thermo Fisher Scientific, Waltham, MA). cDNA was used to generate libraries using the Nextera DNA Flex Enrichment protocol (Illumina, San Diego, CA, catalog number 20025524) with the respiratory virus oligo panel including SARS-CoV-2 probes (Illumina, San Diego, CA, catalog number 20042472) according to manufacturer’s instructions.

Two-pool tailed amplicon library generation and sequencing

To generate cDNA upstream of SARS-CoV-2 genome amplification, the following reaction was set up: 5 μL template RNA, 11 μL nuclease-free water, 4 μL SuperScript IV VILO master mix (Thermo Fisher Scientific, Waltham, MA). cDNA synthesis reactions were incubated at: 25 °C for 10 min, followed by 50 °C for 10 min and 85 °C for 5 min. The SARS-CoV-2 genome was amplified using a two-step PCR protocol. The primary amplification was carried out in a manner similar to the ARTIC v3 method described above, using two primer pools which tile the SARS-CoV-2 genome. The following recipe was used to set up the PCR reactions: 2.5 μL template cDNA, 14.75 μL nuclease-free water, 5 μL 5x Q5 reaction buffer (New England Biolabs, Ipswich, MA), 0.5 μL 10 mM dNTPs (Kapa Biosystems, Woburn, MA), 0.25 μL Q5 Polymerase (New England Biolabs, Ipswich, MA), 2 μL primer pool 1 or 2 (10 μM) for the tailed v1 protocol. Cycling conditions were: 98 °C for 30 s, followed by 25 or 35 cycles of 98 °C for 15 s and 65 °C for 5 min. The primers for the primary amplification contained both SARS-CoV-2 targeting sequences (derived from the ARTIC v3 designs), as well as adapter tails for adding indices and Illumina flow cell adapters in a secondary amplification. These amplification primers had the following structure (see Supplemental Data File 1 for primer sequences):

Left primers: TCGTCGGCAGCGTCAGATGTGTATAAGAGACAG <SARS-CoV-2 LEFT primer>.

Right primers: GTCTCGTGGGCTCGGAGATGTGTATAAGAGACAG <SARS-CoV-2 RIGHT primer>.

The PCR products from pool 1 and pool 2 for each sample were combined and then diluted 1:100 in sterile, nuclease-free water, and a second PCR reaction was set up to add the Illumina flow cell adapters and indices. The secondary amplification was done using the following recipe: 5 μL template DNA (1:100 dilution of the first PCR reaction), 0.7 μL nuclease-free water, 2 μL 5x Q5 reaction buffer (New England Biolabs, Ipswich, MA), 0.2 μL 10 mM dNTPs (Kapa Biosystems, Woburn, MA, 0.1 μL Q5 Polymerase (New England Biolabs, Ipswich, MA), 0.5 μL forward primer (10 μM), 0.5 μL reverse primer (10 μM). Cycling conditions were: 98 °C for 30 s, followed by 10 cycles of 98 °C for 20 s, 55 °C for 15 s, 72 °C for 1 min, followed by a final extension at 72 °C for 5 min. The following indexing primers were used (X indicates the positions of the 10 bp unique dual indices):

Forward indexing primer: AATGATACGGCGACCACCGAGATCTACACXXXXXXXXXXTCGTCGGCAGCGTC.

Reverse indexing primer: CAAGCAGAAGACGGCATACGAGATXXXXXXXXXXGTCTCGTGGGCTCGG.

Four-pool tailed amplicon v2 library generation and sequencing

Samples were processed as described above for the two-pool tailed amplicon sequencing workflow, with the exception that in the first round of PCR, four separate reactions were set up using primer pools 1.1, 1.2, 2.1, and 2.2 (see Supplemental Data File 2 for primer sequences and pool composition) using 2.5 μL of template cDNA per reaction. The four PCR reactions were combined in a 1:1:1:1 ratio after an initial PCR amplification of 35 cycles and a 1:100 dilution of the combined PCRs for each sample was indexed according to the process described above.

Normalization and pooling of tailed amplicon sequencing libraries

10 μL of PCR product for each sample was normalized using a SequalPrep 96-well Normalization Plate Kit (Thermo Fisher Scientific, Waltham, MA). Samples were eluted in 20 μL of elution buffer and 10 μL of each sample was pooled and concentrated to 20 μL using 0.7x AMPureXP beads (Beckman Coulter, Brea, CA). The final pooled sample was quantified using a Qubit Fluorometer and High Sensitivity DNA assay (Thermo Fisher Scientific, Waltham, MA). To confirm the expected library size of approximately 550 bp, pooled libraries were run on either an Agilent Bioanalyzer or TapeStation (Agilent, Santa Clara, CA).

Sequencing

The sample pools were diluted to 2 nM based on the Qubit measurements and Agilent sizing information, and 10 μL of the 2 nM pool was denatured with 10 μL of 0.2 N NaOH. Amplicon libraries (ARTIC v3, Tailed v1, Tailed v2) were diluted to 8 pM in Illumina’s HT1 buffer, spiked with 5% PhiX, and sequenced using a MiSeq 600 cycle v3 kit (Illumina, San Diego, CA). The Nextera DNA Flex Enrichment library was diluted to 10 pM in Illumina’s HT1 buffer, spiked with 1% PhiX, and sequenced using a and a MiSeq 300 cycle v2 kit (Illumina, San Diego, CA).

Analysis

The analysis method for amplicon libraries is as follows:

  • Sample quality was assessed with FastQC [19]. Read-pairs were stitched together using PEAR [20]. Human host DNA was filtered by aligning the stitched reads to the human genome (GRCh38). Reads that did not align to the host genome were aligned to the reference Wuhan-Hu-1 [5] SARS-CoV-2 genome (MN908947.3) using BWA [21]. Amplicon read depths were determined by counting the number of aligned reads covering the base at the center of each amplicon region. The iVar software package was used to trim primer sequences from the aligned reads, and iVar and Samtools mpileup were used to call variants and generate consensus sequences [3]. Variants located outside of the region targeted by the amplicon panel were filtered out (reference genome positions 1–54 and 29,836–29,903), and consensus sequences bases corresponding to those regions were trimmed.

  • The Nextera DNA Flex Enrichment libraries were analyzed using the same process, except the iVar primer trimming step was omitted, and no filtering of variants or trimming of consensus sequence was performed.

Supplementary Information

12864_2020_7283_MOESM1_ESM.docx (2.5MB, docx)

Additional file 1: Supplemental Fig. S1. Samples for initial SARS-CoV-2 sequencing workflow tests. Samples with N1 and N2 Ct values ranging from approximately 20–40 chosen for testing of SARS-CoV-2 sequencing workflows. Supplemental Fig. S2. Coverage metrics by method for sequence capture, ARTIC v3 amplicon, and tailed amplicon workflows. Percentage of genome coverage at 10x at different subsampled read depths for each sample when sequenced using the following approaches: A) Illumina Nextera DNA Enrichment; B) ARTIC v3 with TruSeq library preparation. C) Tailed amplicon v1 (2 pool amplification); D) Tailed amplicon v2 (4 pool amplification). Supplemental Fig. S3. Coverage metrics by sample for sequence capture, ARTIC v3 amplicon, and tailed amplicon workflows. A) Percentage of genome coverage at 10x at different subsampled read depths for the indicated sample when sequenced using the indicated workflow. B) Percentage of genome coverage at 100x at different subsampled read depths for the indicated sample when sequenced using the indicated workflow. Supplemental Fig. S4. Performance metrics for Illumina DNA Flex Enrichment Protocol. Number of total reads generated per sample using the Illumina Nextera DNA Flex Enrichment workflow relative to: A) Sample N1 Ct value; B) Sample N2 Ct value. Percentage of reads aligned to a human reference genome using the Illumina Nextera DNA Flex Enrichment workflow relative to: C) Sample N1 Ct value; D) Sample N2 Ct value. Supplemental Fig. S5. ARTIC v3 amplicon relative abundance. A-F) Observed read depth for each of the expected amplicons for the indicated sample amplified with the ARTIC v3 protocol with TruSeq library preparation at a subsampled read depth of 100,000 raw reads. Supplemental Fig. S6. Tailed amplicon v1 amplicon relative abundance. A-F) Observed read depth for each of the expected amplicons for the indicated sample amplified with the tailed amplicon v1 protocol at a subsampled read depth of 100,000 raw reads. Supplemental Fig. S7. Tailed amplicon v2 amplicon relative abundance. A-F) Observed read depth for each of the expected amplicons for the indicated sample amplified with the tailed amplicon v2 protocol at a subsampled read depth of 100,000 raw reads. Supplemental Fig. S8. Primer dimer formation in tailed amplicon method. A) Agilent TapeStation trace for a library prepared from samples with N1 and N2 Ct values between ~ 20–40 using the tailed amplicon v1 (2 pool amplification) workflow. B) Mean read 1 quality score for samples prepared with the tailed amplicon v1 (2 pool amplification) workflow amplified for either 25 or 35 PCR cycles. C) Percentage of sequencing adapter observed for samples prepared with the tailed amplicon v1 (2 pool amplification) workflow amplified for either 25 or 35 PCR cycles. D) Agilent Bioanalyzer trace for a library prepared from samples with N1 and N2 Ct values between ~ 20–35 using the tailed amplicon v2 (4 pool amplification) workflow. E) Mean read 1 quality score for samples prepared with the tailed amplicon v2 (4 pool amplification) workflow. F) Percentage of sequencing adapter observed for samples prepared with the tailed amplicon v2 (4 pool amplification) workflow. G) 2% agarose gel showing the presence of primer dimers particularly in high N1/N2 Ct samples when indexed using different PCR cycling conditions. Arrow indicates primer dimers on gel. Supplemental Table 1. Percentage of genome coverage at 10x at different subsampled read depths for WA1 and UMGC SARS-CoV-2 isolates sequenced with different methods. For the ARTIC v3, tailed amplicon v1, and tailed amplicon v2 methods, samples were amplified for 35 PCR cycles in the first PCR reaction. Supplemental Table 2. Percentage of genome coverage at 100x at different subsampled read depths for WA1 and UMGC SARS-CoV-2 isolates sequenced with different methods. For the ARTIC v3, tailed amplicon v1, and tailed amplicon v2 methods, samples were amplified for 35 PCR cycles in the first PCR reaction. Supplemental Table 3. Percentage of genome coverage at 10x at different subsampled read depths for WA1 and UMGC SARS-CoV-2 isolates sequenced the tailed amplicon v1 method amplified for 25 PCR cycles in the first PCR reaction. Supplemental Table 4. Percentage of genome coverage at 100x at different subsampled read depths for WA1 and UMGC SARS-CoV-2 isolates sequenced the tailed amplicon v1 method amplified for 25 PCR cycles in the first PCR reaction.

12864_2020_7283_MOESM2_ESM.xlsx (23.1KB, xlsx)

Additional file 2:. Tailed amplicon v1 pool primer sequences.

12864_2020_7283_MOESM3_ESM.xlsx (25.8KB, xlsx)

Additional file 3:. Tailed amplicon v2 pool primer sequences.

Acknowledgements

We thank the staff of the University of Minnesota Genomics Center for helpful discussions and technical support. We thank Brandon Vanderbush for conducting QC on the SARS-CoV-2 samples and sequencing libraries. This work was carried out in part using computing resources at the University of Minnesota Supercomputing Institute. We thank Sean Wang and Matt Plumb from the Minnesota Department of Heath for helpful discussions and for sharing ARTIC v3 primers. We thank Amy Kistler from the Chan-Zuckerberg BioHub, Ryan Donohue, Julie Lau, and Roberto Catteneo from the Mayo Clinic, Jason Blanton from the Florida Department of Health, Yan Li and Suxiang Tong from the Centers for Disease Control and Prevention Pathogen Discover Lab, and Stacia Wyman from the University of California, Berkeley’s Innovative Genomics Institute for sharing unpublished results using the tailed amplicon method described here.

Authors’ contributions

D.M.G. conceived and designed the experiments, conducted experiments, analyzed data, and wrote the manuscript; K.B.B. conceived and designed the experiments and helped write the manuscript; J.G. analyzed data and helped write the manuscript; P.G., J.D., R.W., and B.A. conducted the experiments and helped write the manuscript; A.N. and S.Y. contributed experimental samples and helped write the manuscript. The authors read and approved the final manuscript.

Funding

No funding was obtained for this study.

Availability of data and materials

Sequencing data for this project is available through the National Center for Biotechnology Information (NCBI) Sequence Read Archive BioProject PRJNA631042. Genome sequences of the strains sequenced in this study are available in GenBank BioProject PRJNA631042. The Wuhan-Hu-1 SARS-CoV-2 reference genome (Accession number: MN908947) and the human GRCh38 reference genome primary assembly (Accession number: GCA_000001405.28) used in this study were downloaded from NCBI (https://www.ncbi.nlm.nih.gov/). A detailed protocol is available on protocols.io: https://www.protocols.io/view/sars-cov-2-tailed-amplicon-illumina-sequencing-bipikdke.

Ethics approval and consent to participate

De-identified clinical biospecimens were obtained subsequent to COVID-19 testing at the University of Minnesota under a protocol approved by the University of Minnesota Institutional Review Board (FWA number 00000312): “Detection of COVID 19 by Molecular Methods” (STUDY00009560). The need for informed consent was deemed unnecessary by the IRB. The IRB panel used “WORKSHEET: Human Research (HRP-310)” to make the determination that this study was exempt as not human research as defined by DHHS regulations.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Footnotes

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

The online version contains supplementary material available at 10.1186/s12864-020-07283-6.

References

  • 1.Bedford T, Riley S, Barr IG, Broor S, Chadha M, Cox NJ, et al. Global circulation patterns of seasonal influenza viruses vary with antigenic drift. Nature. 2015;523:217–220. doi: 10.1038/nature14460. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Quick J, Grubaugh ND, Pullan ST, Claro IM, Smith AD, Gangavarapu K, et al. Multiplex PCR method for MinION and Illumina sequencing of Zika and other virus genomes directly from clinical samples. Nat Protoc. 2017;12:1261–1266. doi: 10.1038/nprot.2017.066. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Grubaugh ND, Gangavarapu K, Quick J, Matteson NL, De Jesus JG, Main BJ, et al. An amplicon-based sequencing framework for accurately measuring intrahost virus diversity using PrimalSeq and iVar. Genome Biol. 2019;20:8. doi: 10.1186/s13059-018-1618-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Di Paola N, Sanchez-Lockhart M, Zeng X, Kuhn JH, Palacios G. Viral genomics in Ebola virus research. Nat Rev Microbiol. 2020:1–14. 10.1038/s41579-020-0354-7. [DOI] [PMC free article] [PubMed]
  • 5.Wu F, Zhao S, Yu B, Chen YM, Wang W, Song ZG, et al. A new coronavirus associated with human respiratory disease in China. Nature. 2020;579:265–269. doi: 10.1038/s41586-020-2008-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Hadfield J, Megill C, Bell SM, Huddleston J, Potter B, Callender C. et al, Nextstrain: real-time tracking of pathogen evolution. 10.1093/bioinformatics/bty407. [DOI] [PMC free article] [PubMed]
  • 7.Zhang T, Wu Q, Zhang Z. Probable Pangolin Origin of SARS-CoV-2 Associated with the COVID-19 Outbreak. Curr Biol. 2020;30:1346–1351.e2. 10.1016/j.cub.2020.03.022. [DOI] [PMC free article] [PubMed]
  • 8.Andersen KG, Rambaut A, Lipkin WI, Holmes EC, Garry RF. The proximal origin of SARS-CoV-2. Nat Med. 2020;26:450–452. doi: 10.1038/s41591-020-0820-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Bedford T, Greninger AL, Roychoudhury P, Starita LM, Famulare M, Huang M-L, et al. Cryptic transmission of SARS-CoV-2 in Washington state. Science (80- ). 2020:eabc0523. 10.1126/science.abc0523. [DOI] [PMC free article] [PubMed]
  • 10.Zhou P, Yang XL, Wang XG, Hu B, Zhang L, Zhang W, et al. A pneumonia outbreak associated with a new coronavirus of probable bat origin. Nature. 2020;579:270–273. doi: 10.1038/s41586-020-2012-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Metsky HC, Siddle KJ, Gladden-Young A, Qu J, Yang DK, Brehio P, et al. Capturing sequence diversity in metagenomes with comprehensive and scalable probe design. Nat Biotechnol. 2019;37:160–168. doi: 10.1038/s41587-018-0006-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Vanaerschot M, Mann SA, Webber JT, Kamm J, Bell SM, Bell J, et al. Identification of a polymorphism in the N gene of SARS-CoV-2 that adversely impacts detection by a widely-used RT-PCR assay. bioRxiv. 2020:2020.08.25.265074. 10.1101/2020.08.25.265074. [DOI] [PMC free article] [PubMed]
  • 13.Itokawa K, Sekizuka T, Hashino M, Tanaka R, Kuroda M. A proposal of alternative primers for the ARTIC Network's multiplex PCR to improve coverage of SARS-CoV-2 genome sequencing. bioRxiv. 2020:2020.03.10.985150. 10.1101/2020.03.10.985150.
  • 14.Gohl DM, Vangay P, Garbe J, MacLean A, Hauge A, Becker A, et al. Systematic improvement of amplicon marker gene methods for increased accuracy in microbiome studies. Nat Biotechnol. 2016;34:942–949. doi: 10.1038/nbt.3601. [DOI] [PubMed] [Google Scholar]
  • 15.Harcourt J, Tamin A, Lu X, Kamili S, Sakthivel SK, Murray J, et al. Severe Acute Respiratory Syndrome Coronavirus 2 from Patient with 2019 Novel coronavirus disease, United States. Emerg Infect Dis. 2020;26.1266-73. [DOI] [PMC free article] [PubMed]
  • 16.Gohl DM, Magli A, Garbe J, Becker A, Johnson DM, Anderson S, et al. Measuring sequencer size bias using REcount: a novel method for highly accurate Illumina sequencing-based quantification. Genome Biol. 2019;20:85. doi: 10.1186/s13059-019-1691-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Paden C, Tao Y, Queen K, Zhang J, Li Y, Uehara A, et al. Rapid, sensitive, full-genome sequencing of severe acute respiratory syndrome coronavirus 2. Emerg Infect Dis. 2020;26. 10.3201/eid2610.201800. [DOI] [PMC free article] [PubMed]
  • 18.Nelson AC, Auch B, Schomaker M, Gohl DM, Grady P, Johnson D, et al. Analytical Validation of a COVID-19 qRT-PCR Detection Assay Using a 384-well Format and Three Extraction Methods. bioRxiv. 2020;2019:2020.04.02.022186. [Google Scholar]
  • 19.Andrews S, FastQC A. Quality control tool for high throughput sequence data. 2010. [Google Scholar]
  • 20.Zhang J, Kobert K, Flouri T, Stamatakis A. PEAR: a fast and accurate Illumina paired-end reAd mergeR. Bioinformatics. 2014;30:614–620. doi: 10.1093/bioinformatics/btt593. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Li H, Durbin R. Fast and accurate long-read alignment with burrows–wheeler transform. Bioinformatics. 2010;26:589–95. 10.1093/bioinformatics/btp698. [DOI] [PMC free article] [PubMed]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

12864_2020_7283_MOESM1_ESM.docx (2.5MB, docx)

Additional file 1: Supplemental Fig. S1. Samples for initial SARS-CoV-2 sequencing workflow tests. Samples with N1 and N2 Ct values ranging from approximately 20–40 chosen for testing of SARS-CoV-2 sequencing workflows. Supplemental Fig. S2. Coverage metrics by method for sequence capture, ARTIC v3 amplicon, and tailed amplicon workflows. Percentage of genome coverage at 10x at different subsampled read depths for each sample when sequenced using the following approaches: A) Illumina Nextera DNA Enrichment; B) ARTIC v3 with TruSeq library preparation. C) Tailed amplicon v1 (2 pool amplification); D) Tailed amplicon v2 (4 pool amplification). Supplemental Fig. S3. Coverage metrics by sample for sequence capture, ARTIC v3 amplicon, and tailed amplicon workflows. A) Percentage of genome coverage at 10x at different subsampled read depths for the indicated sample when sequenced using the indicated workflow. B) Percentage of genome coverage at 100x at different subsampled read depths for the indicated sample when sequenced using the indicated workflow. Supplemental Fig. S4. Performance metrics for Illumina DNA Flex Enrichment Protocol. Number of total reads generated per sample using the Illumina Nextera DNA Flex Enrichment workflow relative to: A) Sample N1 Ct value; B) Sample N2 Ct value. Percentage of reads aligned to a human reference genome using the Illumina Nextera DNA Flex Enrichment workflow relative to: C) Sample N1 Ct value; D) Sample N2 Ct value. Supplemental Fig. S5. ARTIC v3 amplicon relative abundance. A-F) Observed read depth for each of the expected amplicons for the indicated sample amplified with the ARTIC v3 protocol with TruSeq library preparation at a subsampled read depth of 100,000 raw reads. Supplemental Fig. S6. Tailed amplicon v1 amplicon relative abundance. A-F) Observed read depth for each of the expected amplicons for the indicated sample amplified with the tailed amplicon v1 protocol at a subsampled read depth of 100,000 raw reads. Supplemental Fig. S7. Tailed amplicon v2 amplicon relative abundance. A-F) Observed read depth for each of the expected amplicons for the indicated sample amplified with the tailed amplicon v2 protocol at a subsampled read depth of 100,000 raw reads. Supplemental Fig. S8. Primer dimer formation in tailed amplicon method. A) Agilent TapeStation trace for a library prepared from samples with N1 and N2 Ct values between ~ 20–40 using the tailed amplicon v1 (2 pool amplification) workflow. B) Mean read 1 quality score for samples prepared with the tailed amplicon v1 (2 pool amplification) workflow amplified for either 25 or 35 PCR cycles. C) Percentage of sequencing adapter observed for samples prepared with the tailed amplicon v1 (2 pool amplification) workflow amplified for either 25 or 35 PCR cycles. D) Agilent Bioanalyzer trace for a library prepared from samples with N1 and N2 Ct values between ~ 20–35 using the tailed amplicon v2 (4 pool amplification) workflow. E) Mean read 1 quality score for samples prepared with the tailed amplicon v2 (4 pool amplification) workflow. F) Percentage of sequencing adapter observed for samples prepared with the tailed amplicon v2 (4 pool amplification) workflow. G) 2% agarose gel showing the presence of primer dimers particularly in high N1/N2 Ct samples when indexed using different PCR cycling conditions. Arrow indicates primer dimers on gel. Supplemental Table 1. Percentage of genome coverage at 10x at different subsampled read depths for WA1 and UMGC SARS-CoV-2 isolates sequenced with different methods. For the ARTIC v3, tailed amplicon v1, and tailed amplicon v2 methods, samples were amplified for 35 PCR cycles in the first PCR reaction. Supplemental Table 2. Percentage of genome coverage at 100x at different subsampled read depths for WA1 and UMGC SARS-CoV-2 isolates sequenced with different methods. For the ARTIC v3, tailed amplicon v1, and tailed amplicon v2 methods, samples were amplified for 35 PCR cycles in the first PCR reaction. Supplemental Table 3. Percentage of genome coverage at 10x at different subsampled read depths for WA1 and UMGC SARS-CoV-2 isolates sequenced the tailed amplicon v1 method amplified for 25 PCR cycles in the first PCR reaction. Supplemental Table 4. Percentage of genome coverage at 100x at different subsampled read depths for WA1 and UMGC SARS-CoV-2 isolates sequenced the tailed amplicon v1 method amplified for 25 PCR cycles in the first PCR reaction.

12864_2020_7283_MOESM2_ESM.xlsx (23.1KB, xlsx)

Additional file 2:. Tailed amplicon v1 pool primer sequences.

12864_2020_7283_MOESM3_ESM.xlsx (25.8KB, xlsx)

Additional file 3:. Tailed amplicon v2 pool primer sequences.

Data Availability Statement

Sequencing data for this project is available through the National Center for Biotechnology Information (NCBI) Sequence Read Archive BioProject PRJNA631042. Genome sequences of the strains sequenced in this study are available in GenBank BioProject PRJNA631042. The Wuhan-Hu-1 SARS-CoV-2 reference genome (Accession number: MN908947) and the human GRCh38 reference genome primary assembly (Accession number: GCA_000001405.28) used in this study were downloaded from NCBI (https://www.ncbi.nlm.nih.gov/). A detailed protocol is available on protocols.io: https://www.protocols.io/view/sars-cov-2-tailed-amplicon-illumina-sequencing-bipikdke.


Articles from BMC Genomics are provided here courtesy of BMC

RESOURCES