A number of antigen-detecting rapid diagnostic tests (Ag-RDTs) for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are now commercially available and can result in rapid decisions on patient care, isolation and contact tracing at the point of care [1]. Two Ag-RDTs using nasopharyngeal (NP) swab samples meet World Health Organization (WHO) targets and are now approved through the WHO Emergency Use Listing procedure [2–4].
Short abstract
Supervised nasal self-sampling is a reliable alternative to professional nasopharyngeal sampling using a WHO-listed SARS-CoV-2 antigen-detecting rapid test. Self-sampling and potentially patient self-testing may be a future use case. https://bit.ly/3mup0hS
To the Editor:
A number of antigen-detecting rapid diagnostic tests (Ag-RDTs) for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are now commercially available and can result in rapid decisions on patient care, isolation and contact tracing at the point of care [1]. Two Ag-RDTs using nasopharyngeal (NP) swab samples meet World Health Organization (WHO) targets and are now approved through the WHO Emergency Use Listing procedure [2–4].
NP swab samples are frequently perceived as uncomfortable by patients and must be collected by trained healthcare personnel with protective equipment. A more complex sampling technique could also result in an incorrect performance in clinical reality, with a possible consequence for test sensitivity. Evidence supports the use of alternative sampling methods for RT-PCR, including nasal swabs collected by patients, and some tests have received regulatory approval with nasal samples [5, 6]. The term nasal sampling is often not used uniformly but can be differentiated in anterior nasal and nasal mid-turbinate sampling [6]. Considering the ease-of-use of Ag-RDTs, a reliable, simple sampling method would not only allow self-sampling, but may also pave the way for self-testing.
The primary objective of this prospective diagnostic accuracy study was a head-to-head comparison (positive and negative percent agreement) of a supervised, self-collected nasal mid-turbinate (NMT) swab sample with a healthcare worker (professional)-collected NP swab sample, using a WHO-listed SARS-CoV-2 Ag-RDT against the reference standard RT-PCR collected from a NP/oropharyngeal (OP) swab. The secondary objective was to assess sensitivity and specificity for different sampling techniques with Ag-RDT. The study was continued until at least 30 positive NP swab samples according to Ag-RDT were obtained, as it was requested by the WHO to approve a novel sample type. This manufacturer-independent study was conducted in partnership with the Foundation of Innovative New Diagnostics (FIND), the WHO collaborating centre for coronavirus disease 2019 (COVID-19) diagnostics.
The study protocol was approved by the ethical review committee at Heidelberg University Hospital for the study site in Berlin (registration number S-180/2020). The study took place at the ambulatory SARS-CoV-2 testing facility of Charité University Hospital (Charité-Universitätsmedizin Berlin, Germany) from 23 September to 14 October 2020. The study enrolled adults at high risk for SARS-CoV-2 infection according to clinical suspicion. Participants were excluded if either of the swabs for the Ag-RDT or the RT-PCR reference standard could not be collected.
Participants underwent first an instructed, self-collected bilateral NMT swab for the Ag-RDT. Verbal instruction was given to insert the swab horizontally 2–3 cm into the nostril and rotate it for 15 s against the nasal walls on each side. Deviations from the instructed technique were recorded. Subsequently, a combined OP/NP swab (eSwab from Copan with 1mL Amies medium) as per institutional recommendations for RT-PCR, and a separate NP swab for the Ag-RDT were taken from different sides of the nose. The samples for the Ag-RDTs were collected using the swab provided by the manufacturer within the test kit.
The Ag-RDT evaluated in this study was the STANDARD Q COVID-19 Ag Test (SD Biosensor, Inc. Gyeonggi-do, Korea; henceforth called STANDARD Q) [7], which is also being distributed by Roche [8]. The test uses the lateral flow assay principle in a cassette-based format with a visual read-out after 15–30 min. The manufacturer's instructions for use were followed. The Ag-RDTs were performed directly after sampling (within 60 min) at point of care by study physicians. The Ag-RDT results were interpreted by two operators, each blinded to the result of the other. The second reader was also blinded to the second Ag-RDT results of individual patients. The visual readout of the Ag-RDT test band was categorised on a semi-quantitative scale as negative, weak positive, positive and strong positive.
The Roche Cobas SARS-CoV-2 assay (Pleasanton, CA, USA) or the SARS-CoV-2 E-gene assay from TibMolbiol (Berlin, Germany) were performed for RT-PCR according to routine procedures at the central laboratory. Viral RNA concentrations were calculated using assay specific cycle threshold values, based on external calibration curves [9, 10]. Staff performing the Ag-RDTs were blinded to results of RT-PCR tests and vice versa.
Of 303 patients invited, 289 (95.4%) consented to participate. Two patients were excluded as both swabs for the Ag-RDT could not be obtained. The mean±sd age of participants was 34.7±11.0 years; 42.9% were female and 19.0% having comorbidities. On the day of testing, 97.6% of participants had one or more symptoms consistent with COVID-19. Duration of symptoms at the time of presentation on average was 4.4±2.7 days. Among the 289 participants, 39 (13.5%) tested positive for SARS-CoV-2 by RT-PCR (table 1).
TABLE 1.
Antigen-detecting rapid diagnostic test (Ag-RDT) results with a supervised self-collected nasal mid-turbinate (NMT) swab and with a professional-collected nasopharyngeal (NP) swab in RT-PCR positive patients from combined NP/oropharyngeal (OP) swab
Number | NMT swab self-collected SD Q Ag-RDT | NP swab professional-collected SD Q Ag-RDT | OP/NP swab RT-PCR | Symptom duration days | |
CT value | Viral load+ | ||||
1 | pos. (+++) | pos. (+++) | 17.33# | 9.59 | 2 |
2 | pos. (++) | pos. (+++) | 17.86# | 9.43 | 1 |
3 | pos. (+++) | pos. (+++) | 18.01# | 9.38 | 1 |
4 | pos. (++) | pos. (+++) | 18.31# | 9.29 | 3 |
5 | pos. (+++) | pos. (+++) | 18.40# | 9.27 | 3 |
6 | pos. (+++) | pos. (+++) | 18.76# | 9.16 | 4 |
7 | pos. (+++) | pos. (+++) | 18.77# | 9.16 | 5 |
8 | pos. (+++) | pos. (+++) | 18.78# | 9.16 | 5 |
9 | pos. (+++) | pos. (+++) | 19.05# | 9.08 | 3 |
10 | pos. (+++) | pos. (+++) | 19.40# | 8.97 | 2 |
11 | neg. | pos. (+++) | 19.66# | 8.90 | 1 |
12 | pos. (+++) | pos. (+++) | 20.32# | 8.70 | 3 |
13 | pos. (+++) | pos. (+++) | 17.81¶ | 8.68 | 4 |
14 | pos. (++) | pos. (+++) | 20.44# | 8.67 | 2 |
15 | pos. (++) | pos. (++) | 20.54# | 8.63 | 5 |
16 | pos. (+++) | pos. (+++) | 21.09# | 8.47 | 4 |
17 | pos. (+++) | pos. (+) | 18.62¶ | 8.44 | 4 |
18 | pos. (+) | pos. (++) | 21.87# | 8.24 | 7 |
19 | pos. (++) | pos. (+++) | 19.34¶ | 8.23 | 5 |
20 | pos. (++) | pos. (+++) | 22.05# | 8.19 | 2 |
21 | pos. (+++) | pos. (+++) | 19.47¶ | 8.19 | 6 |
22 | pos. (+++) | pos. (+++) | 22.60# | 8.03 | 6 |
23 | pos. (+++) | pos. (++) | 23.66# | 7.71 | 6 |
24 | pos. (+) | pos. (++) | 26.42# | 6.90 | 5 |
25 | pos. (+++) | pos. (+++) | 26.77# | 6.79 | 5 |
26 | neg. | neg. | 24.25¶ | 6.78 | 10 |
27 | pos. (++) | pos. (+++) | 24.77¶ | 6.62 | 4 |
28 | pos. (+++) | pos. (++) | 25.29¶ | 6.46 | 2 |
29 | pos. (+) | pos. (++) | 29.33# | 6.03 | 5 |
30 | neg. | neg. | 29.56# | 5.97 | 3 |
31 | neg. | neg. | 29.95# | 5.85 | 3 |
32 | pos. (+) | pos. (+) | 30.25# | 5.76 | 4 |
33 | neg. | neg. | 27.81¶ | 5.72 | 8 |
34 | pos. (++) | pos. (+) | 31.20# | 5.48 | 8 |
35 | neg. | pos. (+) | 31.61# | 5.36 | 10 |
36 | neg. | neg. | 32.58# | 5.07 | 10 |
37 | neg. | neg. | 32.86# | 4.99 | 2 |
38 | neg. | neg. | 34.62# | 4.47 | 7 |
39 | neg. | neg. | 35.53# | 4.20 | 14 |
Sensitivity | 29/39 (74.4%) | 31/39 (79.5%) | |||
Positive percent agreement§ | 90.6% (95% CI 75.8–96.8%) |
Cycle threshold (CT) values and viral load (in descending order) of the paired RT-PCR samples are shown, as well as the duration of symptoms per patient. The positive percent agreement between NMT and NP samples on Ag-RDT, as well as the respective sensitivities compared to RT-PCR are shown. SD Q: STANDARD Q COVID-19 Ag Test (SD Biosensor); neg.: negative; pos. (+): weak positive; pos. (++): positive; pos. (+++): strong positive. #: Roche Cobas SARS-CoV-2 assay (E-gene, T2 target); ¶: TibMolbiol assay, E-gene target; +: log10 RNA SARS-CoV-2 per swab; §: including two false-positives on NMT and one on NP.
No invalid tests were observed on either NMT or NP samples. Two patients were detected by NP but not by NMT sampling. No patient was detected by NMT sampling only. The positive percent agreement was 90.6% (95% CI 75.8–96.8%; including two false-positive results with NMT and one with NP). The negative percent agreement was 99.2% (95% CI 97.2–99.8%). Inter-rater reliability was near perfect with kappa of 0.98 for NMT and 1.0 for NP samples. The semi-quantitative read-out was more often higher for the NP samples (nine higher on NP, four higher on NMT). Of the two patients detected by NP but not by NMT sampling, one patient collected the NMT swab only with gentle rotation, the second presented 10 days post symptom onset with a low viral load (table 1).
The STANDARD Q Ag-RDT with NMT sampling showed a sensitivity of 74.4% (29/39 PCR positives detected; 95% CI 58.9–85.4%) and specificity of 99.2% (95% CI 97.1–99.8%) compared to RT-PCR. The sensitivity with NP sampling was 79.5% (31/39 PCR positives detected; 95% CI 64.5–89.2%) and specificity was 99.6% (95% CI 97.8–100%). In patients with high viral load (>7.0 log10 RNA SARS-CoV-2/swab), the sensitivity of the Ag-RDT with NMT sampling was 95.7% (22/23 PCR positives detected; 95% CI 79.0–99.8%) and 100% (23/23 PCR positives detected; CI 85.7–100) with NP sampling. In contrast, the Ag-RDT frequently did not detect patients with lower viral load or with symptoms >7 days (table 1). For most patients, the application of the flexible swab (meant for NP swab collection) in the nose appeared unpleasant due to a tickling sensation and led to frequent sneezing.
The strengths of the study are the rigorous methods, including standardised sampling, two independent blinded readers and an additional semi-quantitative assessment of Ag-RDT results. The cohort was representative, judging from the comparable sensitivity observed in the recent independent validation study of STANDARD Q (sensitivity 76.6%; 95% CI 62.8–86.4%) [4]. The study is limited as it was performed in a single centre. Also, the NP swab was usually rotated against the nasopharyngeal wall for less time than recommended by the manufacturer, which may have a negative impact on the sensitivity of the Ag-RDT with NP sampling, but also reflects the difficulty of collection of this sample type.
In conclusion, this study demonstrates that supervised self-sampling from the nose is a reliable alternative to professional nasopharyngeal sampling with STANDARD Q. The data will contribute to WHO recommendations for use of this test. Considering the ease of use of Ag-RDTs, self-sampling and potentially patient self-testing at home may be a future use case. If such testing could be repeated frequently and immediately ahead of situations when transmissions are likely to occur, self-testing with Ag-RDTs may have a significant impact on the pandemic. Further implementation studies on optimised self-sampling techniques and swabs (e.g. less flexible sponge swab) and the correct performance/interpretation of the test by patients themselves, are urgently needed to drive self-testing to scale.
Shareable PDF
Acknowledgements
Heike Rössig, Chiara Manon Rohardt, Claudia Hülso, Elisabeth Linzbach, Susen Burock, Katja von dem Busche, Stephanie Padberg, Melanie Bothmann, Zümrüt Tuncer, Stefanie Lunow, Beate Zimmer, Astrid Barrera Pesek, Sabrina Pein, Nicole Buchholz, Verena Haack, Oliver Deckwart.
This study is registered at the German Clinical Trial Registry (DRKS00021220). All raw data and analysis code are available upon a request to the corresponding author; data will be available to researchers who provide a sound proposal and all if study sites agree to sharing the data, for 5 years after publication of the article.
Author contributions: A.K. Lindner, L.J. Krüger, F. Lainati and C.M. Denkinger designed the study and developed standard operating procedures. A.K. Lindner and O. Nikolai implemented the study design, enrolled patients, performed laboratory work and led the writing of the manuscript. F.P. Mockenhaupt and J. Seybold coordinated and supervised the study site. F. Kausch, M. Wintel and F. Hommes enrolled patients. M. Gertler coordinated the testing facility. M. Gaeddert, L. Köppel and F. Tobian led the data analysis. V.M. Corman, J. Hofmann and C. Drosten were responsible for PCR testing and contributed to the interpretation of the data. J.A. Sacks supported the study design setup and the interpretation of the data. C.M. Denkinger was the principle investigator of the study. All authors have reviewed the manuscript.
Conflict of interest: A.K. Lindner has nothing to disclose.
Conflict of interest: O. Nikolai has nothing to disclose.
Conflict of interest: F. Kausch has nothing to disclose.
Conflict of interest: M. Wintel has nothing to disclose.
Conflict of interest: F. Hommes has nothing to disclose.
Conflict of interest: M. Gertler has nothing to disclose.
Conflict of interest: L.J. Krüger has nothing to disclose.
Conflict of interest: M. Gaeddert has nothing to disclose.
Conflict of interest: F. Tobian has nothing to disclose.
Conflict of interest: F. Lainati has nothing to disclose.
Conflict of interest: L. Köppel has nothing to disclose.
Conflict of interest: J. Seybold has nothing to disclose.
Conflict of interest: V.M. Corman has nothing to disclose.
Conflict of interest: C. Drosten has nothing to disclose.
Conflict of interest: J. Hofmann has nothing to disclose.
Conflict of interest: J.A. Sacks reports grants from UK Department of International Development (DFID, recently replaced by FCMO), World Health Organization (WHO) and Unitaid, during the conduct of the study.
Conflict of interest: F.P. Mockenhaupt has nothing to disclose.
Conflict of interest: C.M. Denkinger reports grants from Foundation of Innovative Diagnostics and Ministry of Science, Research and Culture, State of Baden Wuerttemberg, Germany, during the conduct of the study.
Support statement: The study was supported by FIND, Heidelberg University Hospital and Charité University Hospital internal funds, as well as a grant of the Ministry of Science, Research and the Arts of Baden-Württemberg, Germany. FIND provided input on the study design, and data analysis in collaboration with the rest of the study team. Funding information for this article has been deposited with the Crossref Funder Registry.
References
- 1.Foundation of Innovative New Diagnostics (FIND) . SARS-COV-2 Diagnostics Pipeline, 2020. www.finddx.org/covid-19/pipeline/ Date last accessed: 15 Oct 2020.
- 2.World Health Organization . WHO Interim Guidance 11 September 2020. Antigen-detection in the Diagnosis of SARS-CoV-2 Infection using Rapid Immunoassays. https://apps.who.int/iris/bitstream/handle/10665/334253/WHO-2019-nCoV-Antigen_Detection-2020.1-eng.pdf?sequence=1&isAllowed=y Date last accessed: 15 Oct 2020.
- 3.World Health Organization . WHO News Release 28 September 2020. Global Partnership to Make Available 120 Million Affordable, Quality COVID-19 Rapid Tests for Low- and Middle-income Countries. www.who.int/news-room/detail/28-09-2020-global-partnership-to-make-available-120-million-affordable-quality-covid-19-rapid-tests-for-low--and-middle-income-countries. Date last accessed: 15 Oct 2020.
- 4.Krueger LJ, Gaeddert M, Koeppel L, et al. Evaluation of the accuracy, ease of use and limit of detection of novel, rapid, antigen-detecting point-of-care diagnostics for SARS-CoV-2. medRxiv 2020; preprint [ 10.1101/2020.10.01.20203836]. [DOI] [Google Scholar]
- 5.Tu YP, Jennings R, Hart B, et al. Swabs collected by patients or health care workers for SARS-CoV-2 testing. N Engl J Med 2020; 383: 494–496. doi: 10.1056/NEJMc2016321 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Centers for Disease Control and Prevention . Interim Guidelines for Collecting, Handling, and Testing Clinical Specimens for COVID-19. www.cdc.gov/coronavirus/2019-ncov/lab/guidelines-clinical-specimens.html Date last accessed: 15 Oct 2020.
- 7.SD Biosensor . COVID-19 Ag STANDARDTM Q COVID-19 Ag Test 2020. http://sdbiosensor.com/xe/product/7672 Date last accessed: 15 Oct 2020.
- 8.Roche. Roche to Launch SARS-CoV-2 Rapid Antigen Test in Countries Accepting CE Mark, Allowing Fast Triage Decisions at Point of Care. www.roche.com/media/releases/med-cor-2020-09-01b.htm Date last accessed: 15 Oct 2020.
- 9.Matheeussen V, Corman VM, Donoso Mantke O, et al. International external quality assessment for SARS-CoV-2 molecular detection and survey on clinical laboratory preparedness during the COVID-19 pandemic, April/May 2020. Euro Surveill 2020; 25: 2001223. doi: 10.2807/1560-7917.ES.2020.25.27.2001223 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Corman VM, Landt O, Kaiser M, et al. Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR. Euro Surveill 2020; 25: 2000045. doi: 10.2807/1560-7917.ES.2020.25.3.2000045 [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
This one-page PDF can be shared freely online.
Shareable PDF ERJ-03961-2020.Shareable (525.1KB, pdf)