Two-dimensional arrays of vertically packed spin-valves with picoTesla sensitivity at room temperature

Marilia Silva 1,2,, Fernando Franco 1,2,4, Diana C Leitao 1,2, Susana Cardoso 1,2, Paulo P Freitas 1,3
PMCID: PMC7794481  PMID: 33420189

Abstract

A new device architecture using giant magnetoresistive sensors demonstrates the capability to detect very low magnetic fields on the pT range. A combination of vertically packed spin-valve sensors with two-dimensional in-plane arrays, connected in series and in parallel, delivers a final detection level of 360 pT/Hz at 10 Hz at room temperature. The device design is supported by an analytical model developed for a vertically packed spin-valve system, which takes into account all magnetic couplings present. Optimization concerning the spacer thickness and sensor physical dimensions depending on the number of pilled up spin-valves is necessary. To push the limits of detection, arrays of a large number of sensing elements (up to 440,000) are patterned with a geometry that improves sensitivity and in a configuration that reduces the resistance, leading to a lower noise level. The final device performance with pT detectivity is demonstrated in an un-shielded environment suitable for detection of bio-signals.

Subject terms: Spintronics, Electronic and spintronic devices, Sensors and biosensors, Magnetic properties and materials

Introduction

Emerging biomedical applications using portable sensor devices offer patients individualized and improved health monitoring1,2. High precision instruments for magnetic imaging35 are contactless and can offer superior outputs than electrical measurements, since magnetic signals are not attenuated by human tissue6,7. Current technologies for ultra-low magnetic field detection include Superconducting QUantum Interference Devices (SQUID)8 and Optical Pumping Magnetometry (OPM)9,10 reaching femto-tesla detection levels and more recently Spin Exchange Relaxation Free (SERF) atomic magnetometers on pico-tesla range11,12. Despite the very low field detection capability, SQUIDs require cryogenic environments13 and OPMs rely on complex optical parts14, hampering a seamless compact and wearable design. Therefore, the next generation of medical devices demands small and robust solutions with low power consumption and high sensitivity15,16, compatible with electronic integration17,18 and flexible substrates19 for enhanced portability and compactness. A reliable solution for compact devices working at a room temperature can be found in magnetoresistive (MR) sensors2022. Several applications of giant-MR based spin-valve sensors show nT detection levels and high spatial resolution7,2325. To push the detectivity further into pT range, thus becoming competitive with magnetic tunnel junctions26 or hybrid magnetic-MEMS devices27, different solutions were introduced. Large area arrays28,29 and their combination with magnetic flux guides26 have successfully delivered improved performances, at the expense of lower spatial resolution. Given the maturity of stack engineering for spin-valve multilayered thin films24,30, new design strategies are necessary to meet the demands in detection limits. We introduced the concept of a vertically packed arrangement of spin-valve sensors wherein the sensing elements are connected in parallel as seen in Fig. 1a31. The overall device resistance was reduced and consequently the noise level. An improved detectivity was demonstrated while maintaining a compact design for better spatial resolution. However, a strong decrease in sensor sensitivity is also observed due to magnetostatic coupling fields acting on the sensing layers32,33.

Figure 1.

Figure 1

Designs of the spin-valve arrangements considered in this study. (a) Scheme of vertically packed multilayered thin-films with Z=1 for single spin-valve, Z=2 for two vertically packed spin-valves with different TaOx spacer thicknesses (from 500 to 1100 Å), and Z=5,10,N for multiple vertically packed spin-valves with fixed TaOx thickness of 700 Å. (b) Scheme of one-dimensional planar array versus a vertically packed array; both have the elements connected in parallel. (c) Scheme of vertically packed (Z) two-dimensional (XY) array of spin-valves ; optical images of patterned device containing 1000 sensors (X=20, Y=10, Z=5) and the final device with best performance showing 440,000 elements. (d) Scanning electron microscopy (SEM) cross sectional image of a Z=N multilayer. The bright layers corresponds to the spin-valves while dark thick layers are the TaOx (700 Å).

In this work, we present a new solution for an extremely sensitive magnetic device working at room temperature. The sensor architecture combines vertically packed spin-valves separated by an oxide spacer, with an in-plane two-dimensional array of elements (Fig. 1b,c). A new numerical model for packed spin-valves is introduced, accounting for all intra and interlayer magnetic couplings34 to support the design of the multilayered sensor. To achieve high field sensitivity in the vertically packed sensors, non-magnetic spacers can be used or sensor physical dimensions can be changed. The impact of each parameter on the magnetic behavior of the sensing device is addressed. The target is to minimize the effects of the magnetostatic coupling fields that directly affect the linear range of the sensors. The optimized final configuration combines sensors connected in series (X) and in parallel (Y), with vertical packing (Z). For an array of 440,000 elements (Fig. 1c), a record detectivity of 360 pT/Hz at 10 Hz is achieved at room temperature. In an unshielded environment, this device is capable of detecting magnetic fields above 500 pT at low frequencies (35 Hz). With this vertical and planar packing strategy, we push the state-of-the-art in giant magnetoresistive sensors showing improved field detectivity comparable to that of series of magnetic tunnel junction sensors28 and becoming more competitive with fluxgate technology35 displaying pT detectivity3638 with a few cm2 area. Still, the thin film magnetoresitive technology allows to further enhance the spatial resolution by increasing the number of sensors in vertical direction (Z) while reducing the area in the plane; therefore reaching the requirements for bio signal detection at room temperature such as those needed for magnetocardiography39,40 and magnetomyography5.

Results and discussion

Figure 1 shows the fabricated device designs, using spin-valves. A spin-valve is a thin film multilayer structure composed of two ferromagnetic (FM) layers separated by a Cu spacer16. In a top-pinned configuration, the top FM layer has its magnetization direction fixed through exchange bias by an adjacent antiferromagnetic layer, while the magnetization of the bottom FM layer is free to rotate when a small magnetic field is applied, hence sensing layer. The current flows in the plane of the device (CIP) yielding a high resistance value when the magnetization of the two FM layers are antiparallel, and a low resistance when they align parallel to each other. Upon microfabrication, these multilayered systems can be engineered so that the sensing layer magnetization changes its direction through coherent spin rotation. A linear transition between the low and high resistance states is thus achieved being suitable for sensing applications. The micropatterned spin-valve is now sensitive to the strength and direction of the magnetic field (vector sensor)24,4143. The full thin-film structure is obtained by alternating the growth of spin-valves and TaOx, a scheme repeated several times for increased number of vertically packed structures (Z; Fig.1d). Three groups of multilayered thin-films were prepared: (i) single spin-valve (Z=1), (ii) two vertically packed spin-valves (Z=2) with different TaOx thickness (from 500 to 1100 Å), and (iii) multiple vertically packed spin-valves (Z=5,10) with fixed TaOx of 700 Å. The set with Z=5,10 was then patterned into 2D arrays (Fig. 1c) with different element size.

Unpatterned thin-film

Figure 2a–c compares the surface topography of a single spin-valve, a spin-valve/TaOx 700 Å/spin-valve structure and a 700 Å TaOx film. Average roughness values of Ra=2.1 Å, 2.4 Å and 1.2 Å were obtained, respectively. The first value is consistent with literature for these multilayered thin-films44. The TaOx roughness of few Å is within optimum range to grow spin-valve structures. The Ra increases slightly from Z=1 to Z=2 suggesting increased roughness in the top spin-valve structure. A higher offset field (Néel coupling) is expected44, consistent with M(H) results obtained for Z=1 and Z=2 (Fig. S1 from Supplementary Material). Figure 2d shows the normalized transfer curve of the unpatterned Z=2 system with TaOx 700 Å. The minimum resistance is Rmin=13Ω, smaller than Rmin=26Ω for a single spin-valve (Z=1), in line with a system connected in parallel. Figure 2e shows the theoretical output obtained for each spin-valve using the macrospin model and considering different HN45. Equation (1) shows the total energy for the sensing layer of an unpatterned spin-valve film (Z=1):

Etotalfilm=-μ0(Happ+HN)·MSL+Kusin2θ. 1

Figure 2.

Figure 2

AFM images measured on the top surface of (a) a single spin-valve Z=1, (b) a spin-valve /TaOx 700 Å/spin-valve Z=2, and a (c) 700 ÅTaOx film. Transfer curves for (d, e) unpatterned samples and (f, g) micropatterned sensor. (d) Comparison for Z=2 of an experimental normalized R(H) transfer curve for a spacer of TaOx 700 Åand the corresponding simulated output. (e) simulated curves for each individual spin-valve in the system considering the bottom one (SV1) with lower offset field (Hoff) than the top one (SV2) with higher offset field. Input parameters for analytical calculations include Hk and Msat values in Table 1. Normalized transfer curves comparing the double packed spin-valves (Z=2) with TaOx thickness of (f) 700 Åand (g) 1100 Å, and comparison with the single spin-valve structures. Experimental data for patterned structures with w=2μm and l=40μm is compared with the analytic calculations using Eq. (3) and input parameters of Table 1.

Contributions include the external applied magnetic field (Happ), the Néel orange-peel coupling field (HN) acting on the sensing layers, and the intrinsic uniaxial magnetic anisotropy field (Ku) defined during deposition by an applied magnetic field. MSL is the magnetization of the sensing layer45. For unpatterned spin-valve films the effect of the stray fields created by the pinned-layer [top Co80Fe2026 Å], the sensing layer [Ni80Fe20 25/Co80Fe20 28 Å], the self-demagnetizing field due to lateral confinement, and the field created by the flowing current can be neglected. An energy minimum occurs for θ=π for negative external magnetic fields until Hext<-HN+Hk, and for θ=0 if Hext>-HN-Hk, yielding a squared shape (Fig. 2e) where Hoff = HN and the coercivity Hc = Hk. Figure 2e shows the calculations for Z=2 considering decoupled spin-valves . μ0HN=1 mT is considered for the bottom spin-valve (SV1) and μ0HN=1.2 mT for the top spin-valve (SV2). For a Z=2 unpatterned system the final MR/MRmax(H) follows the equivalent resistance formula given by:

MRMRmax=MSLcos(θ1)+MSLcos(θ2)2, 2

where θ represents the angle between the pinned and sensing layers magnetization. These calculations correlate very well with the experimental MR(H) and justify the observed kink (Fig. 2e). The offset field values agree with the increased roughness observed by AFM.

Micropatterned sensor: impact of spacer thickness and physical dimensions

Figure 2f,g compares MR(H) of micropatterned Z=1 and Z=2 spin-valve systems, with TaOx thicknesses of 700 Å and 1100 Å. A MR = 4.5% and a Rmin=698 Ω is obtained for Z=1 and MR = 4% and Rmin=397 Ω for Z=2 (Fig. S2, Supplementary Information). Z=1 shows a non-hysteric behaviour with a linear range of μ0ΔH = 9.5 mT centered at 1.8 mT. A linear fit within ±0.2 mT around the offset field gives a sensor sensitivity S=ΔMRΔH= 0.4%/mT. For Z=2 an increase of the linear range and the offset field is observed, when compared with Z=1. ΔH increases by more than 80%, to 17.8 mT and 17.1 mT for TaOx = 700 Å and TaOx = 1100 Å, respectively. This corresponds to a decrease of field sensitivity of 55% and 45%. The offset field also increases to 4.1 mT for TaOx = 700 Å and 3.5 mT for TaOx = 1100 Å.

A more complex system arises now upon micropatterning, when compared to the one described in Eq. (1). Figure 3a shows a schematic design for Z=2 spin-valves that includes all contributions accounted for in this new macrospin model. Magnetostatic interactions between the two spin-valves are now considered, in addition to self-demagnetizing effects, bias current fields and pinned layer stray fields. For the used Happ range, the pinned layer magnetization is fixed along the magnetic easy axis (Fig. 3a)45.

Figure 3.

Figure 3

(a) Schematic of two spin-valves separated by a TaOx thick spacer for the implementation of the analytical model. SV1 stands for the bottom spin-valve (deposited first) and SV2 is the top spin-valve grown on top of the TaOx spacer. All magnetic field contributions acting on the sensing layers are represented (Happ, Hoff1,2, HPL1,2, Hbias1,2, Hdem1,2). Crossed inter-layer couplings are also added, namely the dipolar fields from SV2 pinned layer and sensing layer (HPL2-1, HSL2-1) acting on SV1 (and vice-versa), and field created from the flowing current Hbias2-1 (and vice-versa). MSL1,2 and MPL1,2 are the magnetizations of the sensing (SL) and pinned (PL) layers, respectively. (b) Employed algorithm to solve the Z=2 spin-valve system. At stage A, the self-demagnetizing and stray fields acting in each SL are calculated, while offset field and induced uniaxial anisotropy are obtained from experimental R(H) curves of unpatterned samples. At stage B two matrices ESV1 and ESV2 are generated with the total energy of the SL of each SV1,2 as a function of external field applied Happ and all combinations of θ1 and θ2. At stage C is initialized a loop to find the θ that minimize the energy for both spin-valves at a given applied field. Firstly, θ1 that minimizes the ESV1 is found for a Happ and θ2k.Then, at stage D is verified if the conditions at C minimizes simultanously the ESV2, otherwise the angle θ2 is swept until both energies are minimized. Consequently, the previous loop restart for a different Happ in order to generate the output at stage E. (c) Calculated linear range (green; Eq. (3)), sensing layer stray field (blue; Eq. (8)) and offset field (light blue; Eq. (3)) as a function of TaOx spacer thickness for Z=2. The star points indicates experimental values for a single SV of ΔH (closed ) and Hoff (open ).

For each sensing layer (SL1 and SL2, Fig. 3a), three inter-layer coupling terms come into play. Acting on SV1 from SV2, are (i) the dipolar field from pinned layer (HPL2-1), (ii) the field created by the current flowing on SV2 (Hbiasj-i) and the (iii) dipolar field from sensing layer (HSL2-1). Similar reasoning is done for the SV2 system. Due to such couplings, SL1,2 magnetization reversal in both spin-valves is not independent. Consequently, the total energy of SV1 (SV2) sensing layer is given by the following macrospin model:

EtotalSV1=-μ0(Hbias1+Happ+HN1+HPL1+Hdem12+Hbias2-1+HSL2-1+HPL2-1)·MSL1+Kusin2(θ). 3

Hdem1 is the self-demagnetizing field while HPL1 and Hbias1 are the stray fields originated by SV1 pinned layer and bias current, respectively. The numerical solution of θ1 and θ2 in Eq. (3), that minimize the entire packed system energy (i.e. considering simultaneously both sensing layers) follows the algorithm depicted in Fig. 3b. The computational diagram is initialized by computing the total energy of each spin-valve. Then, the unique θ1 and θ2 that satisfy the condition of minimum energy for both spin-valves at a certain Happ are found. In the end, only a single energy minimum is considered for a linear output response45.

The input values for the model are summarized in Table 1. The HN1,2, Hk1,2 and saturation magnetization (Msat) for CoFe and NiFe were extracted from unpatterned M(H) curves. A bias current of 1 mA per SV is used, however only 30% is considered to flow through the Cu layer and thus contribute to μ0Hbias1 = 0.1 mT.

Table 1.

Input parameters used for analytic calculations.

Parameter w l μ0HN1 μ0HN2 μ0Hk MsatNiFe MsatCoFe
Value 2 μm 40 μm 1 mT 1.2 mT 0.3 mT 930 kA/m 1250 kA/m

Figure 2f,g compares the calculated output with the experimental curves. The calculated (normalized) MR(H) accurately depicts the experimental data obtained for micropatterned sensors. The significant increase in linear range observed for packed systems is consistent with an inter-layer coupling field that reinforces Hdem, being the main responsible for the decrease in sensitivity. This arises from the stray fields of SL1,2, whose orientation and intensity change according to Happ. Furthermore, the shift in MR(H) also indicates an additional field parallel to the sensing direction. Crossed contributions such as HPL1-2,2-1 and Hbias1-2,2-1 reinforce the Neel coupling.

However, the packed system offset field and linear range can reach those of a single spin-valve using a first approach by increasing the spacer thickness while maintaining the high aspect ratio as shown in Fig. 3c. The calculated linear range (ΔH), dipolar field from SL (Eq. (8)) and offset field are here presented as a function of TaOx thickness. A strong HSL1-2,2-1 is obtained in the low thickness range, vanishing for 5 μm. From this point on, each spin-valve in the Z=2 system becomes magnetically independent, approaching the limit of a single spin-valve (star point in Fig. 3c). The calculated offset field is dependent on the constant values of μ0HPL1,2 (2.9 mT), μ0HN, μ0Hbias1,2 and changing values of μ0HPL1-2 or μ0HPL2-1. When the latter becomes negligible (tTaOx>2.5μm), the Z=2 offset field is comparable to a single spin-valve.

As alternative to magnetically decouple the vertically packed spin-valves, long deposition times of a thick spacer layer can be substituted by engineered physical dimensions of the sensor (w and l). Using the developed macro spin model for double packed spin-valves (Z = 2) and considering a thin spacer layer (e.g. 700 Å), the contributions from the stray fields decrease with increasing w, therefore the HSLj-i along the sensor width decreases very sharply until w=10μm and mostly vanishes above w=80 μm (see Fig. S3 (a) in Supplementary Information). This effect consequently improves the sensitivity and reduces the offset approaching those of a single spin-valve with fixed w=2μm (see Fig. S3 (b) in Supplementary Information). Furthermore, this strategy can be effectively employed for Z>2. The real impact on the MR(H) curve, of altering the physical width (w=2 to 100 μm) in packed systems (Z=5 and Z=10), was experimentally evaluated and compared with calculated curves from the macro spin model for Z = 1 and Z = 10 (Fig. 4a,b). Results from macro spin model for Z = 5 and 10 are shown in Fig. S3 (c)–(h) of the Supplementary Material. Figure 4c compares the sensitivity and hysteresis in all studied structures. Three regions are visible: (i) linear and minimal hysteresis (μ0Hc<0.05 mT), (ii) linear with small hysteresis (μ0Hc>0.1 mT), and (iii) not linear (μ0Hc>0.4 mT) and saturated at zero field.

Figure 4.

Figure 4

Normalized transfer curve of spin-valve sensor for (a) Z = 1 and (b) Z = 10 by varying the width from 2 to 100 μm. For Z = 10 is also shown calculated curves from the developed macrospin model for w = 2 μm and 20 μm. (c) Sensitivity as a function of the sensor width obtained at the most sensitive point of the curve. Three regions are defined to describe the sensor behavior accounting for its hysteresis and linear output.

For Z=1, linear outputs are achieved up to w=5μm, becoming linear and hysteretic until w=10μm and then completely squared. For Z=5 and Z=10, small hysteresis appears above w=5μm,loosing the linearity for w>80μm.

In region (i), the sensitivity for Z>1 is lower than Z=1 since dipolar coupling and demagnetizing field contribute to enlarge the linear operation range. In region (ii), packed spin-valves are still linear although with a small hysteresis for a broad range of w (5 μm<w<80μm). This translates into a sensitivity similar to that observed for a linear Z=1 spin-valve (0.4%/mT). For region (iii), w>80 μm MR(H) becomes square, as the intrinsic anisotropy dominates, hindering its use as a magnetic field sensor. An additional magnetic field, applied perpendicular to the sensing direction, is effective in reducing this hysteresis but adds complexity to the fabrication of a compact device design (Fig. S4 of Supplementary Material)26.

2D arrays: reducing noise, increasing detectivity

In spin-valve sensors the main sources of noise are thermal and 1/f noise29, being the total noise voltage power spectral density (SV) given by:

SV2=4kBTR+γV2ncf, 4

where kB is the Boltzmann constant, T the temperature, R the sensor resistance (R=Rlw), γ the Hooge 1/f noise parameter, V the bias voltage, nc the number of charge carriers (nc=V×C=wltC), and f the frequency. When the system evolves to a packed configuration and its physical dimensions are altered, the noise is given by:

SV2=4kBTRlwZ+γV2ZwltC1f. 5

where Z is the number of packed sensors. By vertically stacking sensors with a large area (w×l) and connected them in parallel, a lower resistance is obtained, promoting a general noise reduction over the entire frequency spectrum. Figure 5a compares the noise level for two devices Z=1, w=2μm and Z=5, w = 20 μm, chosen for their optimal linear output according to the discussion above. Measurements are performed under a bias voltage of 1 V and 100 mV, for Z = 1 and 5 respectively, thus ensuring 1 mA per spin-valve.

Figure 5.

Figure 5

(a) Noise curves for a single Z=1 and Z=5 packed spin-valves, measured at the most sensitive point of the curve (Happ=0). The two dashed lines indicate the calculated thermal noise baseline. The bias voltage was calculated in order to have about 1 mA flowing per each spin-valve. (b) Detectivity curves obtained through the ratio between noise and sensitivity for four devices (Device A, B, C, D in Table 2) with different number of sensors. Device A was biased with 1 V and the others with 3 V. (c) Output of Device D under a bias voltage of 3 V, in an unshielded environment and subjected to variable voltage amplitude applied to the external coil at 35 Hz. The inset shows R(H) of Device D with MR = 6.3%, Rmin=10 kΩ, μ0Hoff=0.2 mT, μ0Hc=0.25 mT and a zero field sensitivity of 1.7%/mT (or 17.2 V/V/T).

Consequently, two devices i and j with different properties (i) Zi, Vi,wi and (j) Zj, Vj,wj reveal a gain Gji in noise level (ratio between the two SV) at low frequency given by:

Gji=ViVj2wjwiZjZi. 6

An improvement (decrease) of 70 times in the noise level is obtained for Z=5 at low frequencies. Although, the spatial resolution increases by a factor of 10, the decrease in the noise level is more significant.

Our approach goes beyond packing sensors in the vertical direction (Z)3133, pushing further on the detection level by using in-plane two-dimensional arrays with X sensors connected in series and Y sensors connected in parallel. The noise level of such XYZ array is now given by:

SV2=4kBTXYZR+γXV2YZwltC1f. 7

An overall improvement of XYZ is therefore expected for the entire noise spectrum considering the same physical dimensions.

A compromise between the physical dimension and sensitivity exists in packed system, and extends to planar arrays. Comparing a device with Z=1, X=40, Y=25 (w=2 μm) and another with Z=5, X=20, Y=10 (w=20 μm), a theoretical gain of 6.4×  at low frequency is predicted. Experimentally, a gain of 5.6×  with an improvement in spatial resolution of 1.5×  is achieved. In fact, only by increasing Z from 5 to 10, while maintaining physical dimensions and XY number of sensors, a larger improvement in spatial resolution of 2× is obtained, although the expected gain in noise is only 2 (Fig. S6 in Supplementary Information).

Figure 5b compares the detectivity level for different devices (A to D), consisting of Z=5 vertically-packed 2D arrays of sensors with w = 20 μm (Table 2). The detectivity is the ratio of the sensor’s noise level and its sensitivity (signal-to-noise ratio equal to 1). The choice of geometrical features considers a compromise between spatial resolution and detectivity. Z=10 could be used for lower noise, however a large w had to be used to ensure linearity and higher sensitivity (see Supplementary Information).

Table 2.

Details of the characterized vertically-packed 2D arrays.

Device A B C D
Lateral size w (μm) 20
Vertically packed Z 5
Connected in series X 20
Connected in parallel Y 10
Device A repetitions (NA) 1 10 110 440
Number of sensors 1000 10,000 110,000 440,000
Detectivity @ 10 Hz (nT/Hz) 6.9 2.4 0.71 0.36
Calculated gain @ 10 Hz 1 3.2 10.0 21.0
Measured gain @ 10 Hz 1 2.9 9.7 19.4

Z is the number of vertical spin-valves, X connected in series and Y in parallel. Sensor A represents an array of X=20, Y=10 and Z=5 with a total number of 1000 sensors. Sensor B, C and D are the array A replicated 10,110 and 440 times, respectively. The detectivity gains, calculated and measured, are obtained relative to Device A.

At 10 Hz, Device A shows a minimum detectable field of 6.9 nT/Hz. Since, the detectivity improves by 1/XYZ (Eq. (7)), pT resolution is possible by increasing the total number of sensors by at least 100 times (gain of 10×). Device A was therefore replicated several times (Devices B, C and D) to achieve the targeted performance (Fig. 1c; Table 2). Due to limitations of the measuring system, Device A was biased with 1 V and the others with 3 V. Nevertheless, at low frequencies (10 Hz) the range for biomedical aplications, the detectivity does not depend on the voltage. The same is not valid for high frequencies where the detectivity varies with 1/V. Comparing the performance at 10 Hz, the best detectivity is obtained for Device D (440,000 sensors) with 360 pT/Hz and a gain of 19.4×. Table 2 summarizes the results obtained for all devices showing a good correlation between measured gain and calculated gain according to N. The drawback of this strategy is the increase in occupied area, which can be partially compensated by larger Z.

Measurements in an un-shielded environment

Device D is then used to measured a very low magnetic field without magnetic shielding, as in a real experiment environment. Figure 5c shows the magnetic field detected by the device. This is obtained from converting of the voltage output into field units using the device sensitivity. The inset of Fig. 5c shows the R(H) transfer curve biased with 3 V and exhibiting a sensitivity of 17.2 V/V/T. The baseline and limit of detection of 360 pT/Hz are obtained with a measurement without any AC signal similar for shielded environment. Then a voltage sweep from 100 to 20 mV was applied, resulting in a magnetic field of 3400 pT/Hz and 800 pT/Hz for the limits of applied voltage. Due to thermal drifts, an increase in the signal baseline during the measurements is visible. The last measurement shows a SNR = 1.7 (4.6 dB) setting the threshold for signal detection.

Conclusions

By merging vertically-packed and in-plane arrays of sensors into a highly sensitive device we are able to detect picoTesla fields in an unshielded environment. Optimized packed spin-valve systems are demonstrated, overcoming the loss of sensitivity due to magnetostatic couplings. Two different routes to mitigate dipolar couplings and improve sensitivity are outlined by the implemented numerical model. This new tool encloses all crossed magnetic coupling terms and allowed us to explore their influence in the self-demagnetizing field of the sensing layers for micropatterned double-packed spin-valve architectures. The first approach requires changing the thickness of TaOx spacer while maintaining the high aspect ratio of the sensing elements, setting the threshold for complete magnetic decoupling at 2.5 μm spacer thickness which poses challenges for experimental implementation. The second route relies on changing the sensor element physical dimensions (low aspect ratio) while preserving a thin and low roughness spacer. Experimentally, two-dimensional arrays of spin-valve elements with Z up to 10, enclosing a thin spacer of 700 Å with low roughness and optimum geometry were successfully fabricated by using standard deposition and micropatterning techniques. An array with five vertically-packed spin-valves and 20 sensing elements connected in series and 10 in parallel replicated 440 times, shows the capacity of measuring pT signals above a detection threshold of 360 pT/Hz at 10 Hz, fitting the specification for biomedical signal detection.

Methods

Growth of vertically packed multilayers

The multilayer thin-films and the insulator spacer were grown with ion beam deposition tools (N3000/N3600). The spin-valve stack used is composed of [Ta 20/Ni80Fe20 25/Co80Fe20 28/Cu 24/Co80Fe20 26/Ir24Mn76 70/Ta 50 (Å)]. The spacer between consecutive spin-valves is tantalum oxide (TaOx). Ta is well known to act as a good buffer for magnetosresistive stacks46,47. TaOx was grown by depositing Ta assisted by a non accelerated O2 plasma (V+=V-=0 V; RF power: 160 W, O2 flow: 10 sccm).

Sensor microfabrication

The spin-valve thin-films were patterned by photolithography and ion milling etching at 70 degrees to obtain a steep lateral profile along the full thickness. For Z=1 and 2 and varying TaOx thickness, a length of l=40μm and width w=2μm was used to define the sensor. For Z = 5 and 10 and tTaOx=700 Å, the structures were patterned with l=40μm and 100 μm, changing w from 20 to 100 μm. Planar arrays (Z=1) and vertically packed arrays (Z=5 and 10) were fabricated with the number of sensors connected in series (X) changing from 10 to 40, and connected in parallel (Y) from 2 to 25 sensors (Fig. 1c). Electrical contacts were defined by liftoff of Al98.5Si1.0Cu0.5 3000/Ti12.5W50N37.5 150 [Å] and passivated with Al2O3 1000 Å. Annealing was then performed at 250C for 30 minutes, and the sample cooled down under an external magnetic field of 1 T.

Characterizations

Unpatterned films were characterized by Vibrating Sample Magnetometry (VSM) and electrically using four point probe measurement. Scanning Electron Microscopy (SEM) was performed in a Raith 150 Ebeam/SEM system. Atomic Force Microscopy (AFM) was performed to access the impact on topography from different TaOx spacer thicknesses. Areas of 500 nm by 500 nm were scanned, with a frequency of 1 Hz and 256 lines.

The patterned structures were measured using a DC two-point probe method with 1 mA bias current within a field range of ±14 mT. The sensor noise spectra were acquired within a frequency range of dc-100 kHz at room temperature on a magnetically shielded box. The device under test is biased through a battery to mitigate the 50 Hz power network component while the output is amplified 100× by a low noise amplifier SIM910 that is connected to a spectrum analyzer.

The evaluation of the limits of detection in an unshielded environment used a low resistance Helmholtz coil (N=8 and r=2.5 cm) connected to a 10 kΩ resistor. The circuit is biased with a AC signal with a voltage changing from 100 mV to 20 mV at a frequency of 35 Hz to create an AC magnetic field (0.34 pT/nA). Each measurement was done with a gain of 100 through a low noise amplifier and averaged 50 times within a resolution bandwidth (RBW) of 1 Hz between 5 and 200 Hz.

Calculation of the demagnetizing field

For the model considered in Eq. (3), only uniformly magnetized media are assumed, and thus a macroscopic description using magnetostatic equations is chosen to calculate Hdem1,2, HPL1,2 and crossed terms HPL1-2, HPL2-1 and HSL1-2, HSL2-148:

Hr=14πSn·M(r)(r-r)|r-r|, 8

where M is the magnetization of the sensing or the pinned layer. Likewise, the field created by the bias current (Hbiasi) can be calculated using48:

Hr=14πVJ(r)×(r-r)|r-r|3d3r, 9

where J is the current density. The overall magnetic field is averaged at mid-thickness of the layer of interest.

Supplementary Information

Acknowledgements

This work has received funding from European Structural & Investment Funds through the COMPETE Program, from National Funds through the Instituto de Nanociencia e Nanotecnologia (IN) Associated Laboratory, National Infrastructure Roadmap NORTE-01-0145-FEDER-22090, MagScopy4IHC - LISBOA-01-0145-FEDER-031200, and PTDC/NAN-MAT/31688/2017. FCT funding of the Research Unit INESC MN (UID/053672020) through plurianual BASE and PROGRAMATICO financing. D.C. Leitao acknowledges financial support through FSE/POPH. M. Silva thanks FCT Doctoral Programme AIM Grant PD/BD/128206/2016. F. Franco acknowledges FCT Grant SFRH/BD/111538/2015.

Author contributions

P.P.F. e S.C. conceived and supervisor the experiment. M.S. deposited, fabricated and characterized the sensors. M.S. and F.F. developed the numerical model. M.S., F.F. and D.C.L. analyzed and interpreted the results and wrote the paper. All authors contributed for the final manuscript.

Competing interests

The authors declare no competing interests.

Footnotes

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary information

is available for this paper at 10.1038/s41598-020-79856-0.

References

  • 1.Kim J, Campbell AS, de Ávila BE-F, Wang J. Wearable biosensors for healthcare monitoring. Nat. Biotechnol. 2019;37:389–406. doi: 10.1038/s41587-019-0045-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Parvez Mahmud MA, Huda N, Farjana SH, Asadnia M, Lang C. Recent advances in nanogenerator-driven self-powered implantable biomedical devices. Adv. Energy Mater. 2018;8:1701210. doi: 10.1002/aenm.201701210. [DOI] [Google Scholar]
  • 3.Boto E, et al. A new generation of magnetoencephalography: room temperature measurements using optically-pumped magnetometers. NeuroImage. 2017;149:404–414. doi: 10.1016/j.neuroimage.2017.01.034. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Fujiwara K, et al. Magnetocardiography and magnetoencephalography measurements at room temperature using tunnel magneto-resistance sensors. Appl. Phys. Express. 2018;11:023001. doi: 10.7567/APEX.11.023001. [DOI] [Google Scholar]
  • 5.Zuo S, Heidari H, Farina D, Nazarpour K. Miniaturized magnetic sensors for implantable magnetomyography. Adv. Mater. Technol. 2020;5:2000185. doi: 10.1002/admt.202000185. [DOI] [Google Scholar]
  • 6.Jensen K, et al. Magnetocardiography on an isolated animal heart with a room-temperature optically pumped magnetometer. Sci. Rep. 2018;8:16218. doi: 10.1038/s41598-018-34535-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Caruso L, et al. In vivo magnetic recording of neuronal activity. Neuron. 2017;95:1283–1291. doi: 10.1016/j.neuron.2017.08.012. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Wang, J., Yang, K., Yang, R., Kong, X. & Chen, W. Gradiometer module for fetal magnetocardiography detection in a thin magnetically shielded room. In 2018 IEEE International Conference on Applied Superconductivity and Electromagnetic Devices (ASEMD), 1–3 (IEEE, 2018).
  • 9.Kim YJ, Savukov I, Huang J-H, Nath P. Magnetic microscopic imaging with an optically pumped magnetometer and flux guides. Appl. Phys. Lett. 2017;110:043702. doi: 10.1063/1.4975069. [DOI] [Google Scholar]
  • 10.Limes ME, et al. Portable magnetometry for detection of biomagnetism in ambient environments. Phys. Rev. Appl. 2020;14:011002. doi: 10.1103/PhysRevApplied.14.011002. [DOI] [Google Scholar]
  • 11.Sulai IA, et al. Characterizing atomic magnetic gradiometers for fetal magnetocardiography. Rev. Sci. Instrum. 2019;90:085003. doi: 10.1063/1.5091007. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Liu, K. et al. Microfabricated SERF atomic magnetometers for measurement of weak magnetic field. In 2020 IEEE 70th Electronic Components and Technology Conference (ECTC) 991–996 (2020).
  • 13.Strand S, et al. Low-cost fetal magnetocardiography: a comparison of superconducting quantum interference device and optically pumped magnetometers. J. Am. Heart Assoc. 2019;8:e013436. doi: 10.1161/JAHA.119.013436. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Tierney TM, et al. Optically pumped magnetometers: from quantum origins to multi-channel magnetoencephalography. NeuroImage. 2019;199:598–608. doi: 10.1016/j.neuroimage.2019.05.063. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Vemishetty N, et al. Low power personalized ECG based system design methodology for remote cardiac health monitoring. IEEE Access. 2016;4:8407–8417. doi: 10.1109/ACCESS.2016.2629486. [DOI] [Google Scholar]
  • 16.Cardoso S, et al. Challenges and trends in magnetic sensor integration with microfluidics for biomedical applications. J. Phys. D Appl. Phys. 2017;50:213001. doi: 10.1088/1361-6463/aa66ec. [DOI] [Google Scholar]
  • 17.Suess D, et al. Topologically protected vortex structures for low-noise magnetic sensors with high linear range. Nat. Electron. 2018;1:362–370. doi: 10.1038/s41928-018-0084-2. [DOI] [Google Scholar]
  • 18.Shafique, M. et al. An overview of next-generation architectures for machine learning: Roadmap, opportunities and challenges in the IoT era. In 2018 Design, Automation & Test in Europe Conference & Exhibition (DATE), 827–832 (IEEE, 2018).
  • 19.Kwon JH, Kwak WY, Cho BK. Magnetization manipulation of a flexible magnetic sensor by controlled stress application. Sci. Rep. 2018;8:15765. doi: 10.1038/s41598-018-34036-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Hirohata A, et al. Review on spintronics: principles and device applications. J. Magn. Magn. Mater. 2020;509:166711. doi: 10.1016/j.jmmm.2020.166711. [DOI] [Google Scholar]
  • 21.Pannetier-Lecoeur M, et al. Magnetocardiography with sensors based on giant magnetoresistance. Appl. Phys. Lett. 2011;98:153705. doi: 10.1063/1.3575591. [DOI] [Google Scholar]
  • 22.Cardoso S, et al. Magnetic tunnel junction sensors with ptesla sensitivity. Microsyst. Technol. 2014;20:793–802. doi: 10.1007/s00542-013-2035-1. [DOI] [Google Scholar]
  • 23.Giouroudi I, Hristoforou E. Perspective: magnetoresistive sensors for biomedicine. J. Appl. Phys. 2018;124:030902. doi: 10.1063/1.5027035. [DOI] [Google Scholar]
  • 24.Zheng C, et al. Magnetoresistive sensor development roadmap (non-recording applications) IEEE Trans. Magn. 2019;55:1–30. [Google Scholar]
  • 25.Adem S, Jain S, Sveiven M. Giant magnetoresistive biosensors for real-time quantitative detection of protease activity. Sci. Rep. 2020;10:1–10. doi: 10.1038/s41598-020-62910-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Valadeiro JP, et al. Strategies for ptesla field detection using magnetoresistive sensors with a soft pinned sensing layer. IEEE Trans. Magn. 2015;51:1–4. [Google Scholar]
  • 27.Valadeiro J, et al. Hybrid integration of magnetoresistive sensors with MEMS as a strategy to detect ultra-low magnetic fields. Micromachines. 2016;7:88. doi: 10.3390/mi7050088. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Paz E, Serrano-Guisan S, Ferreira R, Freitas P. Room temperature direct detection of low frequency magnetic fields in the 100 pt/hz0.5 range using large arrays of magnetic tunnel junctions. J. Appl. Phys. 2014;115:17E501. doi: 10.1063/1.4859036. [DOI] [Google Scholar]
  • 29.Weitensfelder H, et al. Comparison of sensitivity and low-frequency noise contributions in giant-magnetoresistive and tunneling-magnetoresistive spin-valve sensors with a vortex-state free layer. Phys. Rev. Appl. 2018;10:054056. doi: 10.1103/PhysRevApplied.10.054056. [DOI] [Google Scholar]
  • 30.Kim S, Choi J, Lim S. Tailoring of magnetic properties of giant magnetoresistance spin valves via insertion of ultrathin non-magnetic spacers between pinned and pinning layers. Sci. Rep. 2019;19:1–9. doi: 10.1038/s41598-018-38269-w. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31.Silva M, Leitao DC, Cardoso S, Freitas PP. Toward ptesla detectivities maintaining minimum sensor footprint with vertical packaging of spin valves. IEEE Trans. Magn. 2016;53:1–5. doi: 10.1109/TMAG.2015.2487979. [DOI] [Google Scholar]
  • 32.Silva M, Leitao DC, Cardoso S, Freitas P. MnNi-based spin valve sensors combining high thermal stability, small footprint and pTesla detectivities. AIP Adv. 2018;8:056644. doi: 10.1063/1.5007668. [DOI] [Google Scholar]
  • 33.Torrejon J, et al. Multiple giant-magnetoresistance sensors controlled by additive dipolar coupling. Phys. Rev. Appl. 2020;13:034031. doi: 10.1103/PhysRevApplied.13.034031. [DOI] [Google Scholar]
  • 34.Camsari KY, Ganguly S, Datta S. Modular approach to spintronics. Sci. Rep. 2015;5:10571. doi: 10.1038/srep10571. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Ripka P. Review of fluxgate sensors. Sens. Actuators A. 1992;33:129–141. doi: 10.1016/0924-4247(92)80159-Z. [DOI] [Google Scholar]
  • 36.Harada S, Sasada I, Hang F. Development of a one-dimensional fluxgate array and its application to magnetocardiogram measurements. Electron. Commun. Jpn. 2015;98:20–26. doi: 10.1002/ecj.11645. [DOI] [Google Scholar]
  • 37.Song S, et al. Excitation module for orthogonal fundamental mode fluxgate sensor. J. Instrum. 2020;15:P05007–P05007. doi: 10.1088/1748-0221/15/05/P05007. [DOI] [Google Scholar]
  • 38.Bartington Instruments. Mag-13 three-axis magnetic field sensors. https://www.bartington.com/mag-13/. Accessed Apr 2020.
  • 39.TDK. Tdk biomagnetic sensor. https://product.tdk.com/info/en/techlibrary/developing/bio-sensor/index.html. Accessed Apr 2020.
  • 40.Wang M, Wang Y, Peng L, Ye C. Measurement of triaxial magnetocardiography using high sensitivity tunnel magnetoresistance sensor. IEEE Sens. J. 2019;19:9610–9615. doi: 10.1109/JSEN.2019.2927086. [DOI] [Google Scholar]
  • 41.Dieny, B., Gurney, B., Metin, S., Parkin, S. & Speriosu, V. Magnetoresistive sensor based on the spin valve effect. US Patent 5206590A (1992).
  • 42.Heim DE, et al. Design and operation of spin valve sensors. IEEE Trans. Magn. 1994;30:316–321. doi: 10.1109/20.312279. [DOI] [Google Scholar]
  • 43.Freitas PP, Ferreira R, Cardoso S, Cardoso F. Magnetoresistive sensors. J. Phys. Condens. Matter. 2007;19:165221. doi: 10.1088/0953-8984/19/16/165221. [DOI] [Google Scholar]
  • 44.Teixeira J, et al. Ruderman–Kittel–Kasuyama–Yoshida and néel contributions to the interlayer coupling of MNIR-based spin valves: influence of deposition rate, roughness and spacer thickness. J. Appl. Phys. 2008;103:07F319. doi: 10.1063/1.2838141. [DOI] [Google Scholar]
  • 45.Silva AV, et al. Linearization strategies for high sensitivity magnetoresistive sensors. Eur. Phys. J. Appl. Phys. 2015;72:10601. doi: 10.1051/epjap/2015150214. [DOI] [Google Scholar]
  • 46.Ro J-C, Choi Y-S, Suh S-J, Lee H-J. Effect of microstructures on exchange anisotropy in Mn-Ir/Ni-Fe exchange-biased mutilayers with various stacking structures. IEEE Trans. Magn. 1999;35:3925–3927. doi: 10.1109/20.800710. [DOI] [Google Scholar]
  • 47.Bi X, Gan L, Ma X, Gong S, Xu H. Change of coercivity of magnetic thin films with non-magnetic layers and applications to spin valve. J. Magn. Magn. Mater. 2004;268:321–325. doi: 10.1016/S0304-8853(03)00542-0. [DOI] [Google Scholar]