Skip to main content
International Journal of Cardiology Hypertension logoLink to International Journal of Cardiology Hypertension
. 2019 Apr 9;1:100002. doi: 10.1016/j.ijchy.2019.100002

Diurnal changes in central blood pressure and pulse pressure amplification in patients with obstructive sleep apnoea

Yasmina Serinel a,b,c,, Camilla Hoyos a,d, Ahmad Qasem e, Brendon J Yee a,b,f, Ronald R Grunstein a,b,f, Keith H Wong a,b,f, Craig L Phillips a,b,g
PMCID: PMC7803064  PMID: 33447736

Abstract

Study objectives

Recent evidence suggests that compared to peripheral blood pressure (BP), central BP may be more strongly associated with target organ damage and cardiovascular morbidity and mortality. Technological advances now allow the ambulatory measurement of peripheral and central BP over 24 ​h. For the first time, we set out to characterise the diurnal profile of central BP and pulse pressure amplification (PPA) in patients with obstructive sleep apnoea (OSA).

Methods

In this observational study, patients with moderate to severe OSA underwent 24 ​h central and peripheral BP testing before and after at least 4 weeks of CPAP therapy. Concurrent actigraphy was performed to confirm sleep and wake times.

Results

36 patients were screened, 31 had successful testing (mean (SD) age 45 ​± ​10 years, AHI 58 ​± ​27 events/hr, Office BP 136/89 ​± ​10.7/9.5 ​mmHg, 32% on anti-hypertensives, 77% dippers), 21 completed testing post CPAP. Central systolic and diastolic BP followed the same nocturnal dipping profile as peripheral BP, however the peripheral pulse pressure (PP) narrowed in sleep (−3.2 ​mmHg, p ​< ​0.001), whereas the central PP remained unchanged (0.124 ​mmHg, NS), causing a significant reduction in PPA overnight (−10.7%, p ​< ​0.001). The magnitude of dip in central systolic pressure was less than peripheral systolic pressure (by 2.3 ​mmHg, p ​< ​0.001). After treatment with CPAP, the PPA reduction overnight was attenuated (by −3.3%, p ​= ​0.004).

Conclusions

In moderate to severe OSA, central BP and PPA reduce overnight during sleep. Further randomised controlled studies are needed to quantify the differential effects of CPAP and anti-hypertensives on central versus peripheral BP.

Keywords: Blood pressure, Hypertension, Sleep-disordered breathing

1. Introduction

Obstructive sleep apnoea (OSA) is strongly associated with hypertension [1], [2] and widely accepted as a risk factor for secondary hypertension [3], [4]. Management of hypertension is more challenging in patients with OSA as evidenced by higher rates of refractory hypertension, greater nocturnal non-dipping [5], [6], [7], and sub-optimal responses to anti-hypertensives.[8], [9] Furthermore, treatment of OSA with continuous positive airway pressure (CPAP) confers surprisingly modest benefits in terms of reducing blood pressure [10]. Hence, the mechanisms underpinning hypertension in OSA and how to best manage the condition in this vulnerable group are still poorly understood.

For decades, office peripheral (brachial) blood pressure (BP) as measured in a clinic setting has been used to determine future cardiovascular risk. However, 24 ​h ambulatory blood pressure monitoring (ABPM) has established itself as a superior predictor of cardiovascular mortality and morbidity [11], [12]. In particular, the ability to determine nocturnal blood pressure dipping status has greatly improved risk stratification [13]. Despite these advances, a major limitation of peripheral systolic BP is that it does not accurately represent central (aortic) systolic BP. This is because systemic arterial stiffness and its impact on wave reflection can vary both within individuals across time [14] and between individuals. This variation in arterial stiffness and in heart rate will directly alter the magnitude of the reflected component of the pulse pressure wave (augmentation pressure) which will in turn alter central aortic systolic pressure. Importantly, several studies have shown that static measurements of central BP have been associated with target-organ damage [15], [16] and cardiovascular risk, independent of peripheral BP [17], [18].

In this context, a key recent technological advancement has been the development of ambulatory BP devices that are able to capture not only inter-individual differences but also day-night changes in both peripheral and central (aortic) blood pressure [19]. By quantifying sleep aortic BP in particular this technology has the potential to greatly improve risk stratification. Furthermore, studies have shown that anti-hypertensive medications have differential effects on central aortic as opposed to peripheral BP which has significant therapeutic implications [20]. Additionally, the difference between central and peripheral blood pressure, known as pulse pressure amplification (PPA), is emerging as an important novel predictor of future cardiovascular events [21], [22], [23]. This new ambulatory technology therefore allows the examination of wake-sleep changes in PPA thereby providing further novel insights into arterial haemodynamics.

To date there have not been any published studies that have examined 24 ​h central blood pressure and PPA in patients with OSA. Additionally, there have been no studies of the diurnal properties of central BP in this population before and after treatment with CPAP. In this study, we sought to describe for the first time the diurnal nature of peripheral and central blood pressure and PPA over a 24 ​h period in patients with moderate to severe OSA. We also quantified in a smaller group, the relative wake-sleep changes in peripheral and central BP after treatment with CPAP therapy.

2. Methods

2.1. Study design

This was an observational study examining the diurnal profile of peripheral and central blood pressure and pulse pressure amplification in patients with OSA before and after CPAP therapy. The study protocol was approved by the NSW Sydney Local Health District Ethics committee (X15-0360 & HREC/15/RPAH/490). All patients signed a written informed consent.

2.2. Participants

Participants were recruited from a Sleep clinic (Woolcock Institute of Medical Research, Sydney, Australia) between September 2016 and October 2017. Male and female participants were eligible if they were aged 18 to 65yo, had moderate to severe untreated hypoxemic OSA (Apnoea-Hypopnea Index and Oxygen Desaturation Index-3% ≥15/hr), and on fewer than three anti-hypertensive medications. Patient exclusion criteria were: severe hypertension (Office Systolic blood pressure≥180 ​mmHg and/or Diastolic blood pressure≥110 ​mmHg), severe OSA (minimum oxygen saturation ≤65% or Respiratory Disturbance Index>80/hr) with excessive sleepiness at high risk of driving-related accidents, chronic kidney disease (eGFR<60) and uncontrolled medical problems.

All patients underwent gold standard overnight in-laboratory polysomnography to confirm OSA status and severity. Studies were scored according to the American Academy of Sleep Medicine criteria [24]. Once eligible, patients were fitted with the ambulatory blood pressure monitor and cuff (Oscar2 with SphygmoCor Inside, SunTech Medical, Model 250, NC, USA). The appropriate sized cuff was determined by measuring the patient's upper arm circumference. The device is a non-invasive oscillometric ambulatory blood pressure monitor and brachial cuff that is worn by the patient in the community. The machine was set to take readings every 30 ​min over a 24 ​h period. At these set intervals, the cuff inflates to obtain systolic and diastolic pressures based on pressure waves in the artery when occluded by pressure in the cuff (oscillometric method). The machine then deflates to 10 ​mmHg below diastolic pressure and captures volumetric waveforms. It then derives central arterial indices from the captured waveforms using a validated transfer function algorithm. As a peripheral BP device, the Oscar2 has met all requirements according to the International Protocol for the validation of blood pressure machines and the British Hypertension Society [25], [26]. The cuff-based measurement of brachial pressure waves in the Oscar2 and the transfer function for estimating central BP and augmentation index is identical to the SphygmoCor XCEL. This cuff-based technology has been compared against the gold standard non-invasive radial tonometry technology originally developed for SphygmoCor pulse wave analysis machines [27], [28] which were validated against invasive measures of central BP [29]. More recently, the SphygmoCor XCEL estimates of central BP were found to correlate highly with invasively measured brachial and central BP [30]. The studies have shown that estimates of central BP and wave reflection are accurate and exceed criteria for repeatability and reliability [19], [31], [32].

Concurrently, patients wore an actiwatch and completed sleep diaries to document their sleep and wake times. Actigraphy data was analysed manually using Actiware (Phillips Actiware v.6, Respironics Inc, Murrysville PA, USA). The actiware options and settings were as follows: 1. Wake threshold selection was set at medium, 2. Immobile minutes for sleep onset and sleep end were set at 5 ​min. However, one patient demonstrated very frequent movements during sleep and for this study the immobile minutes setting was reduced to zero minutes in order for the software to recognise the period as sleep. Based on the results of the analysed actogram, the investigator then assigned a status of either wake or sleep to each blood pressure recording taken over the 24 ​h period.

Patients were on CPAP for a minimum of 4 weeks before repeat 24 ​h ABPM testing was performed. The settings for CPAP pressure were determined in either one of two ways depending on clinician preference. Either during a single overnight in-laboratory pressure titration sleep study where the pressure was manually titrated until obstructive events were abolished, or by placing the patient on auto-CPAP for a period of 2 weeks and then setting a fixed CPAP pressure based upon the 95th centile pressure applied during the preceding 2 weeks. Patients were reviewed by the CPAP therapist two weeks after commencement of CPAP for optimisation of therapy and at the end of the trial. Patients were reviewed more frequently if the CPAP therapist felt it was clinically indicated to help optimisation and acclimatisation to therapy.

Prior to statistical analysis, all 24 ​h-ABPM data that were deemed artefactual were identified and removed based on Staessen's criteria which included the following readings: systolic blood pressure >240 or <50 ​ ​mmHg, diastolic blood pressure (DBP) ​> ​140 or <40 ​ ​mmHg, heart rate (HR) ​> ​150 or <40 beats/min, and pulse pressure >10% of SBP [33]. As for the central indices, if the augmentation index (AIx) was ≤-80, or >60, this was deemed artefactual and excluded along with the corresponding augmentation pressure (AP) and augmentation index corrected for heart rate (AIX@75) taken during that measurement. Central HR was used rather than peripheral HR as the method of collection is more accurate as the machine measures central HR from the length of the cardiac pulse, whereas peripheral HR is calculated by counting pulses during the oscillometric BP measurement. If peripheral HR and central HR differed by ​> ​10 beats per minute (bpm) then the central measurements were excluded as it indicated a poor quality waveform and only peripheral SBP and peripheral DBP were retained for those readings.

After artefactual readings were excluded, studies were reviewed and deemed unsuccessful if they contained less than 20 valid daytime readings or less than 7 valid night time readings as per European Society of Hypertension guidelines (see flowchart for numbers of excluded studies based on these criteria) [34].

2.3. Statistical analysis

Linear mixed models analyses were used to examine changes in peripheral blood pressure, central blood pressure and indices of wave reflection (AIx, AP) and PPA both before and after CPAP in sleep and wake. A paired t-test was used to compare the wake-sleep change in peripheral SBP and central SBP using mean wake to sleep differences for each patient. All statistical analyses were performed using IBM SPSS version 22.0 for Windows system (SPSS Inc., Chicago, IL). PPA was calculated as the % increase from central to peripheral pulse pressure as follows: ((Peripheral SBP–Peripheral DBP)–(Central SBP–Central DBP))/(Central SBP–Central DBP)) x 100. Non-dipping status was determined by ((Sleep SBP – Wake)/Wake SBP) x 100 ​≤ ​10%.

3. Results

  • 36

    patients were screened and were potentially eligible, 31 patients had successful baseline 24 ​h ABPM testing and 21 of these patients had successful testing post CPAP. The flow chart in Fig. 1 details exclusions and reasons.

Fig. 1.

Fig. 1

Study flowchart. ABPM, ambulatory blood pressure monitoring; CPAP, Continuous positive airway pressure. Studies were deemed unsuccessful based on European Society of Hypertension guidelines.

Patient baseline characteristics are shown in Table 1. The baseline characteristics in the patients that went on to CPAP were similar (data not shown). The mean age was 45 ​± ​10 years and 77% were male. Overall the OSA was severe with mean AHI 58 ​± ​27 events/hr and patients were obese (mean BMI 32.3 ​± ​5.8 ​kg/m2). Hypertension was previously diagnosed in 32% of the patients and all were on antihypertensive therapy, however the mean office BP was within normal limits (<140/90) according to the Australian National Heart Foundation guideline [35]. Patients had an average nightly CPAP compliance of 5.12 ​± ​1.0 ​h with a residual AHI of 4.2 ​± ​3.3 events per hour.

Table 1.

Baseline characteristics of all patientsa.

Characteristic Measure
Demographics(±SD)
Age,yr 45 ​± ​10
Male/female,n 24/7
BMI, kg/m2 32.3 ​± ​5.8
Waist circumference, cm 107.8 ​± ​10.6
Neck circumference, cm 41.9 ​± ​3.7
ESS 10 ​± ​5.4
Office SBP, mmHg 136 ​± ​10.7
Office DBP, mmHg 89 ​± ​9.5
Ambulatory Blood Pressure
Non-dippers, n (%)b 7 (23)
Dippers, n (%)b 24 (77)
Medical history, n (%)
Hypertension 10 (32)
Type 2 diabetes 0 (0)
Hypercholesterolemia 4 (13)
Stroke 0 (0)
Heart failure/Ischaemic heart disease 0 (0)
Current Smoker 2 (6)
Ex-smoker 12 (39)
Anti-hypertensives at baseline, n (%)
Prescribed 10 (32)
1 antiHTN 5 (16)
2 antiHTN 4 (13)
3 antiHTN 1 (3)
PSG values (±SD)
AHI, events/h 58 ​± ​27
ODI, events/h 49 ​± ​27
Min Sa02, % 75 ​± ​11

Plus-minus values are means ​± ​standard deviation. BMI – Body-mass index (weight in kilograms divided by the square of the height in metres), ESS – Epworth Sleepiness Scale, PSG – Polysomnogram, AHI – Apnea-hypopnea index, ODI – Oxygen desaturation index, SaO2 denotes oxygen saturation level as measured by pulse oximetry.

δPPA was calculated as ((P_SBP – P_DBP) – (C_SBP – C_DBP))/(C_SBP – C_DBP)) x 100.

a

Patients included those with successful baseline 24hABPM (n ​= ​31).

b

Non-dipping status was determined by ((Sleep SBP – Wake)/Wake SBP) x 100 ​≤ ​10%.

3.1. Changes in peripheral and central blood pressure and pulse pressure amplification indices between wake and sleep

Baseline peripheral and central blood pressure indices from wake to sleep are shown in Table 2. Both peripheral and central SBP and DBP and HR reduced significantly from wake to sleep demonstrating a diurnal dipping pattern (Fig. 2). Central SBP and DBP both reduced by equal amounts of 17 ​ ​mmHg, however peripheral SBP dropped by 19 ​ ​mmHg, whereas peripheral DBP dropped by 16 ​ ​mmHg, effectively narrowing the peripheral pulse pressure in sleep. The reduction in central SBP was less than that of peripheral SBP (difference 2.3 ​mmHg, p ​< ​0.001). There was a large (∼11%) reduction in PPA from wake to sleep due to the differential reductions in peripheral and central pulse pressure. In subgroup analyses, the reduction in PPA was no different in those with moderate versus severe OSA, or in those with HTN versus without HTN (data not shown).

Table 2.

Peripheral and central ambulatory blood pressure monitoring results in untreated patients n ​= ​31a.

Variable Wake Sleep Difference (sleep minus wake) P value
P_SBP, mmHg 134.8 ​± ​2.0 (130.8–138.8) 115.6 ​± ​2.0 (111.5–119.7) −19.2 <0.001
P_DBP, mmHg 83.8 ​± ​1.4 (80.9–86.6) 67.7 ​± ​1.5 (64.8–70.7) −16.0 <0.001
C_SBP, mmHg 123.9 ​± ​1.8 (120.3–127.5) 106.9 ​± ​1.8 (103.2–110.5) −17.1 <0.001
C_DBP, mmHg 85.3 ​± ​1.5 (82.3–88.4) 68.2 ​± ​1.5 (65.1–71.3) −17.2 <0.001
C_HR, bpm 80.7 ​± ​1.6 (77.4–84.0) 66.9 ​± ​1.6 (63.6–70.2) −13.8 <0.001
C_AP, mmHg 12.5 ​± ​0.7 (11.1–14.0) 14.7 ​± ​0.7 (13.1–16.2) 2.14 <0.001
C_AIx, % 31.0 ​± ​1.3 (28.3–33.7) 37.3 ​± ​1.4 (34.5–40.1) 6.3 <0.001
C_AIx 75, % 33.7 ​± ​1.4 (30.8–36.6) 33.4 ​± ​1.5 (30.4–36.4) −0.319 0.661
P_PP, mmHg 51.0 ​± ​1.3 (48.4–53.7) 47.8 ​± ​1.4 (45.1–50.6) −3.2 <0.001
C_PP, mmHg 38.7 ​± ​1.1 (36.5–40.9) 38.6 ​± ​1.1 (36.4–40.8) 0.124 0.795
PPA, %b 33.3 ​± ​1.1 (31.0–35.6) 22.6 ​± ​1.2 (20.1–25.0) −10.7 <0.001

P_SBP, Peripheral systolic blood pressure; P_DBP, Peripheral diastolic blood pressure; C_SBP, central systolic blood pressure; C_DBP, central diastolic blood pressure; C_HR, central heart rate; C_AP, central augmentation pressure; C_AIx, central augmentation index; C_AIx 75, central augmentation index corrected for heart rate; P_PP, peripheral pulse pressure, C_PP, central pulse pressure; PPA, pulse pressure amplification.

a

Data were analysed using linear mixed models; Values are mean ​± ​standard error, (95% CI).

b

PPA calculated as ((P_SBP – P_DBP) – (C_SBP – C_DBP))/(C_SBP – C_DBP))*100.

Fig. 2.

Fig. 2

Ambulatory peripheral and central blood pressure profile over 24 ​h in untreated patients with OSA. The top panel depicts the percentage of blood pressure readings scored as wake in all patients at any given hour across the 24 ​h period based on actigraphy analysis. The bottom panel depicts the overall mean blood pressure values every hour across the 24 ​h. The shaded area schematically represents augmentation pressure and P1 represents unaugmented central systolic pressure. P_SBP, Peripheral systolic blood pressure; P_DBP, Peripheral diastolic blood pressure; C_SBP, central systolic blood pressure; C_DBP, central diastolic blood pressure.

3.2. Effects of CPAP on peripheral and central BP during wake and sleep

All central and peripheral BP indices before and after CPAP are presented in Table 3. The most notable changes occurred in wake measurements. Wake peripheral and central DBP and HR were reduced after treatment with CPAP whereas wake indices of wave reflection (C_AP, C_AIx, C_AIx 75) increased after treatment. In contrast, sleep indices remained largely unchanged apart from a small drop in HR and a small increase in C_AP. These CPAP associated changes during wakefulness subsequently altered the sleep related changes seen prior to CPAP. In particular, the wake related reduction in C_DBP after CPAP significantly reduced the magnitude of the subsequent sleep related dip that was present before CPAP by 2.4 ​ ​mmHg (p ​= ​0.016). Similarly, the wake related increase in arterial stiffness with CPAP attenuated the magnitude of the sleep related rise in C_AP by 2.2 ​ ​mmHg (p ​< ​0.001) and resulted in an absolute reduction in sleep AIx_75 by 4.6% (p ​< ​0.001). Finally, the nocturnal fall in PPA (∼9%) after CPAP was attenuated by 3.3% (p ​< ​0.004).

Table 3.

Peripheral and central ambulatory blood pressure monitoring results in patients before after treatment with CPAP therapy, n ​= ​21a.

Variable Wake
Sleep
Before CPAP After CPAP Change P value Before CPAP After CPAP Change P value
P_SBP, mmHg 133.0 ​± ​1.6 (129.6–136.4) 133.4 ​± ​1.6 (130.0–136.8) 0.414 0.557 112.2 ​± ​2.0 (108.0–116.4) 112.2 ​± ​2.0 (108.1–116.4) 0.036 0.968
P_DBP, mmHg 84.3 ​± ​1.3 (81.5–87.1) 82.0 ​± ​1.3 (79.2–84.4) −2.287 <0.001 66.7 ​± ​1.4 (63.7–69.7) 66.2 ​± ​1.4 (63.2–69.2) −0.447 0.518
C_SBP, mmHg 122.5 ​± ​1.6 (119.3–125.7) 123.0 ​± ​1.6 (119.8–126.2) 0.492 0.458 104.2 ​± ​1.8 (100.4–108.0) 105.6 ​± ​1.8 (101.8–109.4) 1.428 0.113
C_DBP, mmHg 85.8 ​± ​1.4 (83.0–88.6) 83.1 ​± ​1.4 (80.3–85.9) −2.640 <0.001 67.4 ​± ​1.5 (64.3–70.4) 67.2 ​± ​1.5 (64.1–70.3) −0.188 0.799
C_HR, bpm 80.2 ​± ​2.0 (76.0–84.3) 77.2 ​± ​1.9 (73.0–81.4) −2.931 <0.001 66.5 ​± ​1.5 (63.3–69.7) 63.4 ​± ​1.5 (60.2–66.6) −3.108 <0.001
C_AP, mmHg 11.2 ​± ​1.0 (9.2–13.2) 14.4 ​± ​1.0 (12.4–16.4) 3.146 <0.001 13.8 ​± ​0.7 (12.3–15.2) 14.8 ​± ​0.7 (13.3–16.2) 1.028 0.014
C_AIx, % 29.1 ​± ​1.7 (25.5–32.6) 34.6 ​± ​1.7 (31.0–38.2) 5.554 <0.001 36.7 ​± ​1.4 (33.8–39.6) 37.9 ​± ​1.4 (35.0–40.8) 1.16 0.122
C_AIx 75, % 31.5 ​± ​1.6 (28.1–34.9) 35.7 ​± ​1.6 (32.4–39.1) 4.283 <0.001 32.7 ​± ​1.8 (28.9–36.5) 32.4 ​± ​1.8 (28.7–36.2) −0.283 0.713
P_PP, mmHg 48.7 ​± ​1.2 (46.3–51.1) 51.4 ​± ​1.2 (49.0–53.8) 2.701 <0.001 45.5 ​± ​1.1 (43.2–47.9) 46.0 ​± ​1.2 (43.6–48.4) 0.469 0.488
C_PP, mmHg 36.7 ​± ​1.2 (34.3–39.1) 39.8 ​± ​1.2 (37.4–42.3) 3.126 <0.001 36.8 ​± ​0.9 (34.9–38.7) 38.5 ​± ​0.9 (36.6–40.4) 1.695 0.003
PPA, %ˆ 34.3 ​± ​1.6 (31.0–37.5) 28.9 ​± ​1.6 (25.7–32.2) −5.338 <0.001 22.4 ​± ​0.9 (20.5–24.3) 20.2 ​± ​0.9 (18.3–22.1) −2.185 <0.001
a

Data were analysed using linear mixed models; Values are mean ​± ​standard error (95% CI); P_SBP, Peripheral systolic blood pressure; P_DBP, Peripheral diastolic blood pressure; C_SBP, central systolic blood pressure; C_DBP, central diastolic blood pressure; C_HR, central heart rate; C_AP, central augmentation pressure; C_AIx, central augmentation index; C_AIx 75, central augmentation index corrected for heart rate; P_PP, peripheral pulse pressure, C_PP, central pulse pressure; PPA, pulse pressure amplification; ˆPPA calculated as ((P_SBP – P_DBP) – (C_SBP – C_DBP))/(C_SBP – C_DBP))*100.

4. Discussion

This is the first study to demonstrate the diurnal pattern of central blood pressure (BP) and pulse pressure amplification (PPA) in patients with moderate to severe OSA. We also describe for the first time in a small number of patients, the changes in 24 ​h central BP and PPA after CPAP treatment. We found that similar to peripheral BP, central BP dips during sleep. However, systolic and diastolic BP reduced by different amounts in sleep peripherally and centrally, causing a reduction in peripheral pulse pressure whilst there was no change in the central pulse pressure. This led to a reduction in PPA overnight. This attenuation in PPA was consistent with our findings of an increase in wave reflection during sleep. These results highlight the fact that peripheral BP and central BP and its components behave differently. With CPAP, this attenuation was unexpectedly diluted– not because of a hypothesised decrease in wave reflection during sleep, but instead because of a paradoxical increase during wakefulness.

Our 24 ​h CBP and PPA findings in untreated OSA patients are similar to other very recent studies in hypertensive and normotensive populations without OSA [19], [36], [37], [38]. However to date, only one of these studies explored central BP data with the same Oscar 2 device used in our study [19]. This study in 40 healthy participants demonstrated good-to-excellent inter-day reliability and validity of the Oscar 2 device by comparing static measures with ambulatory values and by repeating ambulatory measures in individuals at different time points. Similar to our study in OSA, they found in healthy participants that the magnitude of drop during the night in central SBP was attenuated as compared to peripheral SBP. The absolute reductions in peripheral and central SBP were comparable to our study (20 ​ ​mmHg and 15 ​ ​mmHg respectively, compared to 19 ​ ​mmHg and 17 ​ ​mmHg in our study).

For any given peripheral SBP, the central SBP will be lower and the magnitude of the difference is measured as pulse pressure amplification. Hence pulse pressure amplification refers to the phenomenon whereby pulse pressure (or the difference between SBP and DBP) increases when moving distally from the heart to the peripheral arterial tree. This amplification in healthy people represents normal physiology, however factors such as aging, and CV risk factors such as hypertension, diabetes mellitus and established CV disease are associated with reduced PPA [21] – which is thought to be chiefly due to a relative increase in aortic SBP as a consequence of increased wave reflection [39], [40]. The development of ambulatory devices that measure central and peripheral BP has revealed that PPA, like peripheral SBP, also dips nocturnally [36], [37], [38], [41]. To the best of our knowledge, we are the first to report on 24 ​h PPA in patients with OSA, finding that PPA reduced by 10% from wake to sleep. Consistent with previous studies in non-OSA groups, we have shown that PPA dipping occurs because of a greater sleep reduction in peripheral pulse pressure as compared to central pulse pressure [36], [37], [38], [41].

With regards to wave reflection (C_AP, C_AIx), several 24 ​h studies in hypertensives and normotensives have found that this increases at night [38], [41], [42] and this likely explains the reduction in PPA during sleep. In our patients with OSA, we found a sleep-related rise of 2 ​ ​mmHg in augmentation pressure and 6% in augmentation index but this effect was negated when corrected for heart rate (C_AIx 75). Only one other study has performed ambulatory measures of AIx in OSA (albeit with a different device and the authors did not report on corresponding central blood pressures) and found no change from day to night [43]. Interestingly, this study also found that control subjects without OSA had a significant drop in AIx from day to night. This contrasts with another much larger study of 500 non-OSA patients (using the same device) which showed a rise in AIx [41]. It is unclear whether the device used had undergone any formal validation to assess the accuracy of the AIx derivation. Certainly, the only directly comparable study to ours, using the validated Oscar 2 (which also measures central BP) found a 4 ​ ​mmHg rise in augmentation pressure, 9% rise in AIx and 3% rise in AIx corrected for HR from daytime to nighttime [19]. These changes in young healthy controls are approximately two-fold greater than the changes we observed in our OSA patients and leads us to speculate that the sleep-related increase in systemic arterial stiffness (as measured by augmentation pressure and augmentation index), is likely to represent normal physiology.

The mechanisms underpinning the drop in PPA and increase in wave reflection which have been shown across studies are not fully understood. It could be argued that these overnight changes could be attributed to changes in posture given the findings of a well-designed study which performed static measurements in awake individuals in the sitting and supine position [44]. The study found that in the recumbent (supine) position, PPA was reduced, whilst measures of wave reflection (augmentation pressure and AIx) all increased [44]. However the absolute sitting-supine change in PPA was less than 4% as compared to nearly ∼11% in our OSA patients and ∼9% in the aforementioned healthy control study [19]. Hence, although recumbent posture might account for some of the overnight change, there are likely to be other mechanisms involved. In this context, the bulk of the increase in augmentation pressure in our study appeared to occur from midnight when most participants were (according to actigraphy) asleep (Fig. 2 top panel and shaded area – bottom panel), suggesting that a change associated with sleep itself is a likely contributing factor. These changes might include a reduction in sympathetic tone which could impact on both vascular tone and heart rate which both impact on the magnitude of wave reflection.

In the context of changes in heart rate with sleep, these likely contribute to both the wake-sleep PPA and AIx changes. It has already been established in studies using static measures that PPA and AIx are directly and inversely related to HR, respectively [39], [40]. In support of this, our analysis found a strong relationship between the wake to sleep change in HR and PPA (r ​= ​0.648, p ​< ​0.001, Fig. 3) in keeping with other 24 ​h study findings [37], [41]. This reduction in HR during sleep increases the duration of ventricular ejection, thereby exposing the left ventricle to a greater proportion of the reflected wave from the lower body. This acts to augment the forward pressure wave in systole thereby increasing augmentation pressure and central systolic blood pressure [39], [40]. This potentially accounts for the attenuated nocturnal dip in central SBP as compared to peripheral SBP. In Fig. 2, we demonstrate schematically this increase in augmentation pressure (shaded area) in parallel with the dampening of the central SBP dip during the night.

Fig. 3.

Fig. 3

24-hour association between PPA and HR in untreated OSA (a) Pulse pressure amplification (b) central HR (c) correlation between change in PPA from wake to sleep versus change in HR from wake to sleep.

Multiple meta-analyses of RCTs have demonstrated that CPAP results in a modest reduction in SBP of approximately 2–3 ​mmHg in patients with OSA and HTN [45], [46], [47], [48], [49]. Only one study has looked at the effect of CPAP on 24 ​h-ABPM in normotensive OSA patients and found that whilst the SBP was unchanged, 24 ​h DBP and daytime DBP reduced significantly by 1.38 ​ ​mmHg and 1.39 ​ ​mmHg respectively [50]. Similarly, in our mostly normotensive patients, treatment with CPAP resulted in a reduction in wake peripheral and central DBP as well as wake and sleep HR. We had postulated that following elimination of OSA with CPAP, there would also be a reduction in wave reflection across both the wake and sleep periods. Instead there was an increase during the wake period after CPAP. Whilst the cause for the wake-related increase is unclear, it did not carry through to the subsequent sleep period. Although highly speculative, this lack of absolute change in the magnitude of wave reflection during sleep may represent two opposing effects. The reduction in sympathetic activity with CPAP could potentially decrease arterial stiffness thereby reducing augmentation pressure. In contrast, a reduction in sympathetic activity would also lower heart rate, which would increase augmentation pressure. The combined effects would be neutral.

The increase in wave reflection (AP,AIx and CAIx75) during wakefulness after CPAP is contrary to the findings from other studies using static office-based measurements which have consistently shown a reduction [51], [52]. Similarly, an attenuated PPA dip with CPAP is difficult to explain seeing as the expected effects of treatment overnight such as a reduction in sympathetic activity, and reduction in left ventricular afterload, should all theoretically cause a further reduction in sleep PPA. Interestingly, a large cross-sectional 24 ​h study of patients with suspected or established hypertension paradoxically found one of the factors associated with less PPA dipping at night was the use of antihypertensives [41]. Also of interest is that beta blockers, unlike other anti-hypertensives, have been shown to decrease PPA, by having a much more marked effect on lowering peripheral BP as compared to central BP [53]. Clearly the impact of blood pressure lowering treatments on the haemodynamic changes between wake and sleep are complex and not yet fully understood. Ultimately, although the effect of CPAP involved only a relatively small sample of patients, we did find in secondary analyses (results not shown) that the increase in wake AP after CPAP was a consistent finding in 19 of the 21 patients studied. Nevertheless these effects need to be replicated with a larger study and appropriate control group.

Overall, whilst this study is novel in exploring central hemodynamic changes across the sleep-wake cycle in OSA, it is limited by its observational design and small sample size. It is further limited by an even smaller sample of patients completing the CPAP follow up. Secondly, a non-OSA comparator group would have strengthened the study, as well as a sham CPAP arm to confirm that the changes were related to CPAP use. Given the lack of a control group, we compared our baseline values to a study with healthy participants (albeit of a younger demographic with a greater proportion of females) that used the same device. Finally, despite the severity of the underlying OSA, the group were largely normotensive and it remains to be determined whether similar wake-sleep changes in central BP and PP amplification would occur in a hypertensive OSA group and whether CPAP treatment would differentially alter these measures. The strengths of this study were that we utilised gold standard in-lab polysomnography for accurate identification of our patients, and more importantly, we utilised individualised wake and sleep times for each patient by using actigraphy as well as sleep diaries. This means that measures of sleep-wake changes are technically more accurate and this has not been replicated in any of the other 24 ​h central BP studies. Lastly, we used a blood pressure device that was validated not only for central BP readings but also for AIx.

New ambulatory technology has allowed us to describe for the first time the diurnal variation of central blood pressure and pulse pressure amplification in OSA, a population at risk of poor cardiovascular outcomes. There is emerging data to suggest that these hemodynamic findings may be better predictors of target organ damage and future cardiovascular risk than peripheral brachial measurements. Central blood pressure is importantly, a more accurate representation of end-organ BP exposure including the heart and kidneys. Furthermore, central BP changes differently to peripheral blood pressure during sleep and in response to different anti-hypertensives. This study paves the way for future research in the hypertensive OSA population, specifically inexamining the effects of CPAP on central blood pressure and the differential therapeutic and chronotherapeutic effects of various classes of anti-hypertensives.

Statement of significance

Advances in technology now allow the non-invasive measurement of 24 ​h ambulatory central blood pressure (BP) and pulse pressure amplification (PPA). In this study we characterise for the first time the diurnal profile of central BP and PPA in patients with obstructive sleep apnoea (OSA). We found that central and peripheral BP behaved differently across the 24 ​h. During sleep, peripheral pulse pressure (PP) narrowed, whereas central PP did not, causing a significant reduction in PPA overnight. After treatment with CPAP, the PPA reduction overnight was attenuated. This novel study provides a new direction for future research to better understand arterial haemodynamics and cardiovascular risk stratification in OSA, a group in which hypertension is difficult to control.

Disclosure statement

Financial Disclosures: YS was supported by an Australian National Health and Medical Research Council (NHMRC) scholarships (#1114750 and #1060992). CLP was supported by an NHMRC Career Development Fellowship (#1061545) and a Sydney Medical School Foundation Chapman Fellowship. RRG was supported by an NHMRC Senior Principle Research Fellowship (#1106974). Additional support came from NHMRC Project Grant #632758.

Non-financial disclosures

None.

Acknowledgments

The authors would like to thank A/Prof Delwyn Bartlett for assistance with actigraphy analysis, the Woolcock CPAP therapists for assisting the patients with CPAP. Lastly we would like to thank our patients for their time and involvement and for making this study possible.

Footnotes

This study was performed at the NHMRC Centre for Integrated Research and Understanding of Sleep (CIRUS), and NHMRC Neurosleep Centre Woolcock Institute of Medical Research, The University of Sydney, NSW 2006, Australia.

References

  • 1.Marin J.M., Agusti A., Villar I. Association between treated and untreated obstructive sleep apnea and risk of hypertension. Jama. 2012;307(20):2169–2176. doi: 10.1001/jama.2012.3418. [published Online First: 2012/05/24] [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Peppard P.E., Young T., Palta M. Prospective study of the association between sleep-disordered breathing and hypertension. N. Engl. J. Med. 2000;342(19):1378–1384. doi: 10.1056/nejm200005113421901. [published Online First: 2000/05/11] [DOI] [PubMed] [Google Scholar]
  • 3.Chobanian A.V., Bakris G.L., Black H.R. The seventh report of the joint national committee on prevention, detection, evaluation, and treatment of high blood pressure: the JNC 7 report. Jama. 2003;289(19):2560–2571. doi: 10.1001/jama.289.19.2560. [DOI] [PubMed] [Google Scholar]
  • 4.Lavie P., Herer P., Hoffstein V. Obstructive sleep apnoea syndrome as a risk factor for hypertension: population study. BMJ (Clinical research ed) 2000;320(7233):479–482. doi: 10.1136/bmj.320.7233.479. [published Online First: 2000/03/04] [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Pankow W., Nabe B., Lies A. Influence of sleep apnea on 24-hour blood pressure. Chest. 1997;112(5):1253–1258. doi: 10.1378/chest.112.5.1253. [published Online First: 1997/11/21] [DOI] [PubMed] [Google Scholar]
  • 6.Mokhlesi B., Hagen E.W., Finn L.A. Obstructive sleep apnoea during REM sleep and incident non-dipping of nocturnal blood pressure: a longitudinal analysis of the Wisconsin Sleep Cohort. Thorax. 2015;70(11):1062–1069. doi: 10.1136/thoraxjnl-2015-207231. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Hla K.M., Young T., Finn L. Longitudinal association of sleep-disordered breathing and nondipping of nocturnal blood pressure in the Wisconsin Sleep Cohort Study. Sleep. 2008;31(6):795–800. doi: 10.1093/sleep/31.6.795. [published Online First: 2008/06/14] [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Thunstrom E., Manhem K., Rosengren A. Blood pressure response to losartan and CPAP in hypertension and obstructive sleep apnea. Am. J. Respir. Crit. Care Med. 2015 doi: 10.1164/rccm.201505-0998OC. [published Online First: 2015/09/29] [DOI] [PubMed] [Google Scholar]
  • 9.Serinel Y., Yee B.J., Grunstein R.R. Chronotherapy for hypertension in obstructive sleep apnoea (CHOSA): a randomised, double-blind, placebo-controlled crossover trial. Thorax. 2017;72(6):550–558. doi: 10.1136/thoraxjnl-2016-209504. [published Online First: 2016/12/16] [DOI] [PubMed] [Google Scholar]
  • 10.Schein A.S., Kerkhoff A.C., Coronel C.C. Continuous positive airway pressure reduces blood pressure in patients with obstructive sleep apnea; a systematic review and meta-analysis with 1000 patients. J. Hypertens. 2014;32(9):1762–1773. doi: 10.1097/hjh.0000000000000250. [published Online First: 2014/07/01] [DOI] [PubMed] [Google Scholar]
  • 11.Dolan E., Stanton A., Thijs L. Superiority of ambulatory over clinic blood pressure measurement in predicting mortality: the Dublin outcome study. Hypertension. 2005;46(1):156–161. doi: 10.1161/01.HYP.0000170138.56903.7a. [published Online First: 2005/06/09] [DOI] [PubMed] [Google Scholar]
  • 12.Mancia G., Zanchetti A., Agabiti-Rosei E. Ambulatory blood pressure is superior to clinic blood pressure in predicting treatment-induced regression of left ventricular hypertrophy. SAMPLE Study Group. Study on Ambulatory Monitoring of Blood Pressure and Lisinopril Evaluation. Circulation. 1997;95(6):1464–1470. doi: 10.1161/01.cir.95.6.1464. [published Online First: 1997/03/18] [DOI] [PubMed] [Google Scholar]
  • 13.Boggia J., Li Y., Thijs L. Prognostic accuracy of day versus night ambulatory blood pressure: a cohort study. Lancet. 2007;370(9594):1219–1229. doi: 10.1016/s0140-6736(07)61538-4. [DOI] [PubMed] [Google Scholar]
  • 14.Phillips C., Hedner J., Berend N. Diurnal and obstructive sleep apnea influences on arterial stiffness and central blood pressure in men. Sleep. 2005;28(5):604–609. doi: 10.1093/sleep/28.5.604. [published Online First: 2005/09/21] [DOI] [PubMed] [Google Scholar]
  • 15.Roman M.J., Devereux R.B., Kizer J.R. Central pressure more strongly relates to vascular disease and outcome than does brachial pressure: the Strong Heart Study. Hypertension. 2007;50(1):197–203. doi: 10.1161/hypertensionaha.107.089078. [published Online First: 2007/05/09] [DOI] [PubMed] [Google Scholar]
  • 16.Kollias A., Lagou S., Zeniodi M.E. Association of central versus brachial blood pressure with target-organ damage: systematic review and meta-analysis. Hypertension. 2016;67(1):183–190. doi: 10.1161/hypertensionaha.115.06066. [published Online First: 2015/11/26] [DOI] [PubMed] [Google Scholar]
  • 17.Vlachopoulos C., Aznaouridis K., O'Rourke M.F. Prediction of cardiovascular events and all-cause mortality with central haemodynamics: a systematic review and meta-analysis. Eur. Heart J. 2010;31(15):1865–1871. doi: 10.1093/eurheartj/ehq024. [published Online First: 2010/03/04] [DOI] [PubMed] [Google Scholar]
  • 18.Agabiti-Rosei E., Mancia G., O'Rourke M.F. Central blood pressure measurements and antihypertensive therapy: a consensus document. Hypertension. 2007;50(1):154–160. doi: 10.1161/hypertensionaha.107.090068. [published Online First: 2007/06/15] [DOI] [PubMed] [Google Scholar]
  • 19.Burns M.J., Seed J.D., Incognito A.V. Comparison of laboratory and ambulatory measures of central blood pressure and pulse wave reflection: hitting the target or missing the mark? J. Am. Soc. Hypertens. JASH. 2018 doi: 10.1016/j.jash.2018.01.014. [published Online First: 2018/02/27] [DOI] [PubMed] [Google Scholar]
  • 20.Williams B., Lacy P.S., Thom S.M. Differential impact of blood pressure-lowering drugs on central aortic pressure and clinical outcomes: principal results of the Conduit Artery Function Evaluation (CAFE) study. Circulation. 2006;113(9):1213–1225. doi: 10.1161/circulationaha.105.595496. [published Online First: 2006/02/16] [DOI] [PubMed] [Google Scholar]
  • 21.Avolio A.P., Van Bortel L.M., Boutouyrie P. Role of pulse pressure amplification in arterial hypertension: experts' opinion and review of the data. Hypertension. 2009;54(2):375–383. doi: 10.1161/hypertensionaha.109.134379. [published Online First: 2009/07/01] [DOI] [PubMed] [Google Scholar]
  • 22.Benetos A., Thomas F., Joly L. Pulse pressure amplification a mechanical biomarker of cardiovascular risk. J. Am. Coll. Cardiol. 2010;55(10):1032–1037. doi: 10.1016/j.jacc.2009.09.061. [published Online First: 2010/03/06] [DOI] [PubMed] [Google Scholar]
  • 23.Papaioannou T.G., Protogerou A.D., Stefanadis C. What to anticipate from pulse pressure amplification. J. Am. Coll. Cardiol. 2010;55(10):1038–1040. doi: 10.1016/j.jacc.2009.09.063. [published Online First: 2010/03/06] [DOI] [PubMed] [Google Scholar]
  • 24.Berry R.B., Budhiraja R., Gottlieb D.J. Rules for scoring respiratory events in sleep: update of the 2007 AASM manual for the scoring of sleep and associated events. Deliberations of the sleep apnea definitions task force of the American Academy of sleep medicine. J. Clin. Sleep Med. 2012;8(5):597–619. doi: 10.5664/jcsm.2172. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Jones S.C., Bilous M., Winship S. Validation of the OSCAR 2 oscillometric 24-hour ambulatory blood pressure monitor according to the International Protocol for the validation of blood pressure measuring devices. Blood Press. Monit. 2004;9(4):219–223. doi: 10.1097/00126097-200408000-00007. [published Online First: 2004/08/18] [DOI] [PubMed] [Google Scholar]
  • 26.Goodwin J., Bilous M., Winship S. Validation of the Oscar 2 oscillometric 24-h ambulatory blood pressure monitor according to the British Hypertension Society protocol. Blood Press. Monit. 2007;12(2):113–117. doi: 10.1097/MBP.0b013e3280acab1b. [published Online First: 2007/03/14] [DOI] [PubMed] [Google Scholar]
  • 27.Hwang M.H., Yoo J.K., Kim H.K. Validity and reliability of aortic pulse wave velocity and augmentation index determined by the new cuff-based SphygmoCor Xcel. J. Hum. Hypertens. 2014;28(8):475–481. doi: 10.1038/jhh.2013.144. [published Online First: 2014/01/17] [DOI] [PubMed] [Google Scholar]
  • 28.Butlin M., Qasem A., Avolio A.P. Conference Proceeding Annual International Conference of the IEEE Engineering in Medicine and Biology Society IEEE Engineering in Medicine and Biology Society Annual Conference. Vol. 2012. 2012. Estimation of central aortic pressure waveform features derived from the brachial cuff volume displacement waveform; pp. 2591–2594. [published Online First: 2013/02/01] [DOI] [PubMed] [Google Scholar]
  • 29.Pauca A.L., O'Rourke M.F., Kon N.D. Prospective evaluation of a method for estimating ascending aortic pressure from the radial artery pressure waveform. Hypertension. 2001;38(4):932–937. doi: 10.1161/hy1001.096106. [published Online First: 2001/10/20] [DOI] [PubMed] [Google Scholar]
  • 30.Shoji T., Nakagomi A., Okada S. Invasive validation of a novel brachial cuff-based oscillometric device (SphygmoCor XCEL) for measuring central blood pressure. J. Hypertens. 2017;35(1):69–75. doi: 10.1097/hjh.0000000000001135. [published Online First: 2016/10/21] [DOI] [PubMed] [Google Scholar]
  • 31.Young Y., Abdolhosseini P., Brown F. Reliability of oscillometric central blood pressure and wave reflection readings: effects of posture and fasting. J. Hypertens. 2015;33(8):1588–1593. doi: 10.1097/hjh.0000000000000604. [published Online First: 2015/07/03] [DOI] [PubMed] [Google Scholar]
  • 32.Stoner L., Bonner C., Credeur D. Reliability of oscillometric central hemodynamic responses to an orthostatic challenge. Atherosclerosis. 2015;241(2):761–765. doi: 10.1016/j.atherosclerosis.2015.06.041. [published Online First: 2015/07/06] [DOI] [PubMed] [Google Scholar]
  • 33.Staessen J., Fagard R., Lijnen P. Ambulatory blood pressure monitoring in clinical trials. J. Hypertens. Suppl. Off. J. Int. Soc. Hypertens. 1991;9(1):S13–S19. [PubMed] [Google Scholar]
  • 34.O'Brien E., Parati G., Stergiou G. European Society of Hypertension position paper on ambulatory blood pressure monitoring. J. Hypertens. 2013;31(9):1731–1768. doi: 10.1097/HJH.0b013e328363e964. [DOI] [PubMed] [Google Scholar]
  • 35.Gabb G.M., Mangoni A.A., Anderson C.S. Guideline for the diagnosis and management of hypertension in adults - 2016. Med. J. Aust. 2016;205(2):85–89. doi: 10.5694/mja16.00526. [published Online First: 2016/07/28] [DOI] [PubMed] [Google Scholar]
  • 36.Williams B., Lacy P.S., Baschiera F. Novel description of the 24-hour circadian rhythms of brachial versus central aortic blood pressure and the impact of blood pressure treatment in a randomized controlled clinical trial: the Ambulatory Central Aortic Pressure (AmCAP) Study. Hypertension. 2013;61(6):1168–1176. doi: 10.1161/hypertensionaha.111.00763. [published Online First: 2013/05/01] [DOI] [PubMed] [Google Scholar]
  • 37.Jankowski P., Bednarek A., Olszanecka A. Twenty-four-hour profile of central blood pressure and central-to-peripheral systolic pressure amplification. Am. J. Hypertens. 2013;26(1):27–33. doi: 10.1093/ajh/hps030. [published Online First: 2013/02/06] [DOI] [PubMed] [Google Scholar]
  • 38.Boggia J., Luzardo L., Lujambio I. The diurnal profile of central hemodynamics in a general Uruguayan population. Am. J. Hypertens. 2016;29(6):737–746. doi: 10.1093/ajh/hpv169. [published Online First: 2015/10/18] [DOI] [PubMed] [Google Scholar]
  • 39.Wilkinson I.B., MacCallum H., Flint L. The influence of heart rate on augmentation index and central arterial pressure in humans. J. Physiol. 2000;525 Pt(1):263–270. doi: 10.1111/j.1469-7793.2000.t01-1-00263.x. [published Online First: 2000/05/16] [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 40.Wilkinson I.B., Mohammad N.H., Tyrrell S. Heart rate dependency of pulse pressure amplification and arterial stiffness. Am. J. Hypertens. 2002;15(1 Pt 1):24–30. doi: 10.1016/s0895-7061(01)02252-x. [published Online First: 2002/02/05] [DOI] [PubMed] [Google Scholar]
  • 41.Argyris A.A., Nasothimiou E., Aissopou E. Mechanisms of pulse pressure amplification dipping pattern during sleep time: the SAFAR study. J. Am. Soc. Hypertens. JASH. 2017 doi: 10.1016/j.jash.2017.12.005. [published Online First: 2017/12/31] [DOI] [PubMed] [Google Scholar]
  • 42.Lluberas S., Bia D., Zocalo Y. [Sleep-wakefulness variations in arterial stiffness: assessment using ambulatory recording of arterial pulse transit time] Revista espanola de cardiologia. 2008;61(1):41–48. [published Online First: 2008/01/29] [PubMed] [Google Scholar]
  • 43.Sarinc Ulasli S., Sariaydin M., Ozkececi G. Arterial stiffness in obstructive sleep apnoea: is there a difference between daytime and night-time? Respirol. (Carlton, Vic) 2016 doi: 10.1111/resp.12845. [published Online First: 2016/07/07] [DOI] [PubMed] [Google Scholar]
  • 44.Vrachatis D., Papaioannou T.G., Konstantopoulou A. Effect of supine versus sitting position on noninvasive assessment of aortic pressure waveform: a randomized cross-over study. J. Hum. Hypertens. 2014;28(4):236–241. doi: 10.1038/jhh.2013.101. [published Online First: 2013/10/25] [DOI] [PubMed] [Google Scholar]
  • 45.Hu X., Fan J., Chen S. The role of continuous positive airway pressure in blood pressure control for patients with obstructive sleep apnea and hypertension: a meta-analysis of randomized controlled trials. J. Clin. Hypertens. (Greenwich) 2015;17(3):215–222. doi: 10.1111/jch.12472. [published Online First: 2015/01/15] [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46.Bazzano L.A., Khan Z., Reynolds K. Effect of nocturnal nasal continuous positive airway pressure on blood pressure in obstructive sleep apnea. Hypertension. 2007;50(2):417–423. doi: 10.1161/HYPERTENSIONAHA.106.085175. [DOI] [PubMed] [Google Scholar]
  • 47.Alajmi M., Mulgrew A.T., Fox J. Impact of continuous positive airway pressure therapy on blood pressure in patients with obstructive sleep apnea hypopnea: a meta-analysis of randomized controlled trials. Lung. 2007;185(2):67–72. doi: 10.1007/s00408-006-0117-x. [published Online First: 2007/03/30] [DOI] [PubMed] [Google Scholar]
  • 48.Montesi S.B., Edwards B.A., Malhotra A. The effect of continuous positive airway pressure treatment on blood pressure: a systematic review and meta-analysis of randomized controlled trials. J. Clin. Sleep Med. 2012;8(5):587–596. doi: 10.5664/jcsm.2170. [published Online First: 2012/10/16] [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 49.Fava C., Dorigoni S., Dalle Vedove F. Effect of CPAP on blood pressure in patients with OSA/hypopnea a systematic review and meta-analysis. Chest. 2014;145(4):762–771. doi: 10.1378/chest.13-1115. [published Online First: 2013/10/01] [DOI] [PubMed] [Google Scholar]
  • 50.Sapina-Beltran E., Santamaria-Martos F., Benitez I. Normotensive patients with obstructive sleep apnoea: changes in 24-h ambulatory blood pressure monitoring with continuous positive airway pressure treatment. J. Hypertens. 2018 doi: 10.1097/hjh.0000000000001934. [published Online First: 2018/09/21] [DOI] [PubMed] [Google Scholar]
  • 51.Vlachantoni I.T., Dikaiakou E., Antonopoulos C.N. Effects of continuous positive airway pressure (CPAP) treatment for obstructive sleep apnea in arterial stiffness: a meta-analysis. Sleep Med. Rev. 2013;17(1):19–28. doi: 10.1016/j.smrv.2012.01.002. [published Online First: 2012/05/12] [DOI] [PubMed] [Google Scholar]
  • 52.Phillips C.L., Butlin M., Wong K.K. Is obstructive sleep apnoea causally related to arterial stiffness? A critical review of the experimental evidence. Sleep Med. Rev. 2013;17(1):7–18. doi: 10.1016/j.smrv.2012.03.002. S1087-0792(12)00028-7 [pii] 10.1016/j.smrv.2012.03.002 [published Online First: 2012/06/05] [DOI] [PubMed] [Google Scholar]
  • 53.Suojanen L., Haring A., Tikkakoski A. Haemodynamic influences of bisoprolol in hypertensive middle-aged men: a double-blind, randomized, placebo-controlled cross-over study. Basic Clin. Pharmacol. Toxicol. 2017;121(2):130–137. doi: 10.1111/bcpt.12771. [published Online First: 2017/03/04] [DOI] [PubMed] [Google Scholar]

Articles from International Journal of Cardiology Hypertension are provided here courtesy of Elsevier

RESOURCES