Summary
Bioelectronic devices that convert biochemical signals to electronic readout enable biosensing with high spatiotemporal resolution. These technologies have been primarily applied in biomedicine while in plants sensing is mainly based on invasive methods that require tissue sampling, hindering in-vivo detection and having poor spatiotemporal resolution. Here, we developed enzymatic biosensors based on organic electrochemical transistors (OECTs) for in-vivo and real-time monitoring of sugar fluctuations in the vascular tissue of trees. The glucose and sucrose OECT-biosensors were implanted into the vascular tissue of trees and were operated through a low-cost portable unit for 48hr. Our work consists a proof-of-concept study where implantable OECT-biosensors not only allow real-time monitoring of metabolites in plants but also reveal new insights into diurnal sugar homeostasis. We anticipate that this work will contribute to establishing bioelectronic technologies as powerful minimally invasive tools in plant science, agriculture and forestry.
Subject areas: Biotechnology, Bioelectronics, Plant Physiology
Graphical abstract
Highlights
-
•
In vivo, real-time monitoring of sugars fluctuations in trees with OECTs for 48hr
-
•
OECTs reveal previously uncharacterized diurnal sucrose fluctuations in aspen
-
•
Multienzyme functionalization of OECT for detection of sucrose
-
•
Operation of sensors with low-cost portable unit
Biotechnology; Bioelectronics; Plant Physiology
Introduction
Bioelectronics enable electronic interfacing with the biological world as means for monitoring or stimulating biological processes. The bioelectronics field is highly driven by applications in biomedicine, specifically finding new solutions for diagnosis and therapy (Berggren and Richter-Dahlfors, 2007; Zeglio et al., 2019). Organic electronic devices can be advantageous when applied in the biological milieu since organic electronic materials support sufficient electronic and ionic transport (Paulsen et al., 2020), in a highly coupled manner, and thus enable efficient signal transduction. While the majority of efforts lie within the animal kingdom, applying bioelectronics to other biological organisms has emerged with successful demonstrations of sensing and actuation in bacteria (He et al., 2012; Pitsalidis et al., 2018; Zajdel et al., 2018; Demuru et al., 2019; Di Lauro et al., 2020) and plants (Stavrinidou et al., 2015, 2017; Coppedè et al., 2017; Poxson et al., 2017; Bernacka-Wojcik et al., 2019; Janni et al., 2019; Kim et al., 2019; Vurro et al., 2019; Diacci et al., 2020). Recently, we presented an implantable organic electronic ion pump for in vivo delivery of abscisic acid, one of the main hormones involved in plant stress responses (Bernacka-Wojcik et al., 2019), and subsequently the electronic control of physiology in intact plants. Others demonstrated conformable electrodes based on conducting polymers that were directly printed on plant leaves for long term bioimpedance monitoring (Kim et al., 2019). In another work, a yarn-based organic electrochemical transistor (OECT) has been used for electrolyte monitoring in tomato plants in physiological conditions (Coppedè et al., 2017), while in following works, the same concept was used to monitor drought stress (Janni et al., 2019) or changes in vapor pressure deficit (Vurro et al., 2019). Our group coupled an OECT directly with isolated chloroplasts to monitor in real-time the glucose export from the plant organelles with unprecedented time resolution (Diacci et al., 2020). The OECT is a three terminal device where a gate electrode modulates the current, via reduction-oxidation switching of a conducting polymer-based channel (Nilsson et al., 2002; Rivnay et al., 2018). The OECTs operate in aqueous environments and when the gate electrode is functionalized with an enzyme the OECT is converted to an enzymatic biosensor (Tang et al., 2011). When the analyte is present in the solution, an electrochemical reaction takes place at the gate, which becomes amplified through the modulation of the channel current. Signal amplification of the OECTs is important particularly for miniaturized devices where high signal to noise ratio is challenging. Although OECTs have received a lot of attention as amplification biosensors, their application in complex biological environments has been very limited. So far, most of the enzymatic OECT sensors have been validated in test solutions for the detection of metabolites and neurotransmitters (Shim et al., 2009; Kergoat et al., 2014; Liao et al., 2014; Berto et al., 2018; Pappa et al., 2018). Few demonstrations have been reported where glucose is monitored from natural samples such as sweat (Scheiblin et al., 2015) saliva (Liao et al., 2015; Pappa et al., 2016), or cell media (Curto et al., 2017; Strakosas et al., 2017) and one example focused on epidermal patches for on-body detection (Parlak et al., 2018). Until now, there is no demonstration of an implantable OECT enzymatic sensor for monitoring an analyte directly within the in vivo environment.
Sugars are produced by photosynthesis and play a central role in plant growth and development. Several of the primary sugar metabolic pathways, responsible for carbon allocation in plants, are relatively well described. One of the current challenges in the field is to understand how the metabolic pathways of sugar metabolism are regulated, and how changes in sugar flux or concentration are adjusted. In order to address these questions, methods allowing for spatial and temporal real-time quantification of sugar levels are needed. The development of Förster resonance energy transfer (FRET)–based nanosensors for sugars was the first step toward in vivo measurements of sugar pools (Deuschle et al., 2006; Chaudhuri et al., 2011). Genetically encoded FRET sensors enable the analysis of steady-state concentration of sugar and dynamic changes in living tissue with high temporal and even subcellular resolution. However, the use of FRET sugar sensors is limited to cells and tissues, which can be monitored using a microscope. Cells buried deep in tissues, as is the case of vascular system, for example, are not accessible. Therefore, sugar analysis in plants, is usually performed by invasive methods that have poor spatial and temporal resolution and lead to disposal of the organism or tissue after sampling. Furthermore, sample analysis requires extraction/processing followed by sugar level determination based on enzymatic assays (Graf et al., 2010), mass spectrometry (Jorge et al., 2016) or high-performance liquid chromatography (Mayrhofer et al., 2004). All of these methods have high accuracy and low detection limit, but do not enable in vivo real time sugar level monitoring and therefore impede kinetic studies and analysis of biologically relevant events within the living plant.
In several tree species, including the model tree aspen, sucrose is the predominant form of transported carbon (Rennie and Turgeon, 2009). Sucrose is primarily transported in the phloem to different parts of the plant, but sucrose is also transported within the xylem transpiration stream (Heizmann et al., 2001; Mayrhofer et al., 2004). It was estimated that 9–28% of the carbon delivered to leaves in 3-month-old Populus trees over a diurnal cycle was derived from sugars transported in the transpiration stream (Mayrhofer et al., 2004). Several tree species also use the xylem pathway to transport sugars during flowering and bud flush in the spring (Sauter and Ambrosius, 1986). Xylem sap composition is typically analyzed from exudate secreted from a cut stem or leaf petiole. Sometimes, root pressure is sufficient to push out the xylem sap from the cut, but often a pressure chamber is required to squeeze out the sap and there is always a concern that xylem sap may mix with phloem sap or other cell contents at the cut surface. Furthermore, these invasive methods disrupt the transpiration stream, and do not allow monitoring of the sap composition over time. In this work, we overcome the above limitations by developing implantable glucose and sucrose OECT-based sensors that enable in vivo real time monitoring in plants (Figure 1). As a demonstration of the proof-of-concept and the kind of biological insights that this technology enables, we observed previously uncharacterized diurnal changes in sucrose levels in the xylem sap of greenhouse-grown hybrid aspen (Populus tremula x tremuloides).
Results and discussion
OECT-based sugar sensors
The OECT-based glucose and sucrose sensors were fabricated on a 125-μm-thick polyethylene naphthalate (PEN) substrate using standard microfabrication techniques as described in the Transparent Methods section. Ti/Au is used for source, drain, gate electrodes, and for wiring while the channel is based on the conducting polymer poly(3,4-ethyl-enedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS). The gate electrode is coated with a PEDOT:PSS thin film in order to increase its capacitance for efficient modulation of the channel conductance and is then further functionalized with enzymes and PtNPs. The PtNPs were electrodeposited on the gate while the enzymes were immobilized with the help of a chitosan matrix that is drop-casted onto the gate.
The PEDOT:PSS-based OECT operates in the depletion mode with the channel initially at the high conductance state. When a positive bias is applied at the gate, cations from the electrolyte will penetrate into the channel, compensating the PSS polymer dopants resulting in PEDOT de-doping and a decrease in the channel current (Khodagholy et al., 2013). When the analyte is present in the solution an enzymatic reaction will take place at the gate that will result in the generation of H2O2. The H2O2 will then be oxidized on the PtNPs on the gate, which is associated with a transfer of electrons that change the effective gate potential and consequently induce a further decrease in the channel current (Bernards et al., 2008) (Figure 2A). Typical transfer curve and transconductance of the OECT are shown in Figure 2B. The transconductance is considered the figure of merit of OECT sensor devices as describes the change in the drain current over the change in gate potential, gm = ΔID/ΔVG. Therefore, operation of the device at the high transconductance regime will result in small changes in the gate potential to induce large changes in the channel current. The analytes possible to detect by the enzymatic electrochemical sensors are limited by the availability of enzymes that can take part in redox reactions. Glucose oxidase is an oxido-reductase enzyme that catalyzes the oxidation of β-D-glucose to hydrogen peroxide and D-glucose1,5-lactone. Sucrose on the other hand does not have a corresponding oxidoreductase enzyme. In order to detect sucrose enzymatically, we overcame this limitation by incorporating successfully three enzymes within the chitosan matrix enabling a cascade of reactions to take place in a confined space. First, invertase hydrolyzes sucrose into fructose and α-D-glucose, mutarotase then catalyzes the conversion of α-D-glucose into β-D-glucose and finally β-D-glucose reacts with the glucose oxidase enzyme, Figure 2A.
The performance and sensitivity range of the OECT-based glucose and sucrose sensors were assessed by monitoring the relative change of the channel current in solutions containing increasing concentration of sugars. To achieve high sensitivity, we operated the transistor at voltages across the gate, VGS = +0.5 V and channel, VDS = −0.4 V (source grounded), where the OECT has high transconductance, and thus exhibiting high amplification of the sensor signal. In order to compare the response of different devices and extract the characteristic calibration curve of the sensor we calculated the normalized drain current response of the device for each analyte concentration (ΔI/I = −(I[Μ]−I0)/I0), where I[Μ] is the drain current at concentration M and I0 is the base drain current. In Figure 2C, we show the calibration curves of the sucrose and glucose sensors represented as the mean of the response of 8 and 5 different devices, respectively. We observe that the sensors have similar, close to identical, characteristics with a dynamic range within 100 μM - 1 mM, as a result of the same concentration of glucose oxidase enzyme in the sucrose and glucose sensor. Furthermore, our biofunctionalization strategy allows us to tune the sensitivity and dynamic response of the sensor by changing the concentrations of the enzymes within the chitosan matrix. As shown in Figure S1, the sensor becomes sensitive to higher concentrations of sucrose when we reduce the enzymes concentrations. Additionally, we tested the sensitivity of the sucrose sensor to glucose. Indeed, we observe that the sucrose sensor is sensitive to glucose as it is expected, Figure S2. Therefore, for the in vivo detection of glucose and sucrose both independent sensors were used simultaneously. Finally, we evaluated the stability of the sensor in the complex biochemical environment of the plant. Sucrose sensor devices (n = 3) were implanted in the bark of hybrid aspen trees for 48hr and after being removed from the tree their response to 100μM and 300μM of sucrose test solutions was assessed as shown in Figure 2D. We observe a small decrease in the sensor response in comparison with the standard calibration curve of the sucrose sensors but the difference is not statistically significant.
Device integration and portable measurement setup
Next, we proceed to develop a portable OECT measurement unit set-up based on a low-cost Arduino platform that allow us to perform the sensing experiment in the growth environment of plants. In this case, the measurements were performed inside the greenhouse while these devices can be also operated in growth chambers or even in field conditions (Figures 3A and 3B). As the platform uses uni-polar analog-to-digital and digital-to-analog converters it was operated using a common drain configuration (i.e. drain was grounded) in order to avoid negative voltages (Figure 3C). Two identical but separate circuits were used to source gate and source voltages ( and) and simultaneously measure gate and source currents (IG and IS).
Each circuit was composed of a voltage output ( or) connected to one end of a precision resistor (RGor RS). The other end of the resistor was connected to a voltage input ( or) and to the gate or source terminals. The drain terminal was connected to the ground of the microcontroller. Externally the gate, source and drain terminals were connected to the OECT using a ZIF connector and a ribbon cable (Figure 3B). Two proportional-integral-derivative (PID) controllers were used to control the voltages applied to the gate and source terminals of the OECT. Upon application of Vout, the voltage loss over R reduces the voltage at the gate/source terminal. The PID compensates for this by measuring Vin and modulating Vout so that Vin matches the desired gate/source voltage. The voltage over R, obtained from the difference between Voutand Vin, was used to calculate IG and ISthrough Ohm's law using the known value of R.
OECT insertion and wounding response
In order to perform meaningful in vivo measurements with the OECT sensors it is important to minimize wound responses caused by the sensor insertion. Wounding responses may interfere with the measurements by altering the physiological processes of interest. Therefore, we first evaluated the response to the insertion of the sensor. We used hybrid aspen (Populus tremula x tremuloides) as our model system and mature xylem as the tissue of interest. The OECT design was optimized for this specific biological system. The sensors were fabricated on a flexible and thin PEN substrate with a thickness of 125 μm to ensure enough mechanical stability that enables easy insertion while decreasing the footprint to minimize invasiveness. Moreover the device was encapsulated with an SU-8 layer in order to ensure that only the active area of the transistor, gate and channel are exposed to the plant environment. The length of the implanted part of the sensor was chosen to be 3 mm to guarantee that the active sensor site reaches the mature xylem tissue and transpiration stream and the width chosen to 1 mm. An initial incision with a scalpel was performed to allow sensor insertion to the correct site at 3 mm depth from the epidermis (Figure 4A). This ensured that the sensor gate and channel are located within the mature xylem and are in contact with the transpiration stream. Any local wound response is unlikely to have a substantial effect on the composition of the xylem sap flowing past the sensor, but tissue repair responses may eventually lead to the isolation of the sensor from the transpiration stream. Therefore, wound responses due to the OECT insertion was analyzed over a time course of 1, 2, and 5 days using an optical light microscope. The visual changes in the insertion site were recorded using a camera and analyzed in more detail by preparing 60 μm thick cross sections across the insertion site using a vibratome (Figure 4B). The cross sections were stained with Toluidine Blue O solution to aid the visualization of the cell walls and any tissue level changes. These assays established that a local wound response due to OECT implantation was evident after 48 hr and obvious after 5 days when also a cork tissue formation was observed (Figure 4B). Hence, the following in vivo sugar measurements were limited to the first 48 hr following sensor insertion.
Real-time sugar monitoring via implantable OECTs
Sucrose and glucose OECT-based sensors were implanted into the mature xylem of greenhouse grown 8-week-old hybrid aspen trees, and operated at constant gate voltage of VGD = +0.5 V and constant source-drain voltage of VDS = −0.4 V for 24 hr or 48 hr. Prior to the insertion in the trees, the sensors were treated with oxygen plasma to induce hydrophilicity and to improve the device performance within the xylem tissue (Figure S3). As a control, a device without any included enzyme(s) but with the PtNPs and chitosan matrix was inserted in the same region as the sensor devices. The control device allowed evaluation of any changes in the device response that were not caused from the presence of sugars. Interestingly, the sucrose sensor revealed a variation of the current between day-time and night-time, establishing that sucrose concentration in the xylem sap increases during darkness and decreases at the onset of the light period (Figures 5A and S4). To our knowledge, this is the first time that such diurnal fluctuation in sucrose concertation is observed in xylem sap. At the same time, glucose and control devices did not display any variation between day and night, indicating that glucose homeostasis is not affected by the sucrose changes (Figures 5A and S4). We always observed the same trend in increase of sucrose during the dark period, but the relative magnitude of the changes between different experiments within the same tree or different trees varied. The differences in relative magnitude may be explained by subtle internal and environmental differences, which are known to influence sucrose pools in plants (Farrar et al., 2000). The average change of the normalized response from day-time to night-time for the sucrose sensors is equal to (Inigh-Iday)/Iday = 0.24 ± 0.1, n = 11), while in the control and glucose sensors there were no significant changes in the current (Figure 5B). We chose to treat our data only qualitatively and not to attempt to quantify the sucrose levels within the xylem due to the uncertainty of the concentration of sucrose in xylem prior insertion of the sensor as will be described below.
In order to compare the OECT findings with conventional methods, we analyzed day and night samples of xylem sap from aspen trees that were collected using the classical stem cutting and sap bleeding method (Alexou and Peuke, 2013). This is a highly invasive method where the tree stem is cut, the phloem is mechanically removed and the xylem sap is collected as it bleads out from the stem (Figure S5). The collected samples are then analyzed using an enzymatic assay (Stitt et al., 1989). The ex vivo analysis also showed an increase in xylem sap sucrose levels at night (Tables S1 and S2). However, unlike the in vivo measurements with the OECT sensors also glucose levels increased during night (Tables S1 and S2). We suspect that the glucose increase is due to the disruptive nature of the stem cutting and sap bleeding. With this method, pith cells are injured; therefore they are contributing to the collected liquid. Additionally, invertase enzymes, that are known to be induced by wounding (Roitsch and González, 2004), can catalyze sucrose cleavage to glucose and fructose. In support of this hypothesis, fructose levels increased similarly to glucose in the xylem sap collected from the cut stems (Tables S1 and S2). The ex vivo analysis limitations and uncertainties highlight the importance of developing minimally invasive in vivo methods for monitoring sugars variations in plants and show how the OECT technology can overcome some of these limitations. Although we could attempt to quantify sucrose concentration changes based on the OECTs sensors response and taking as initial sucrose concertation the daytime value as determined from the ex vivo analysis, we avoided to do so considering all the uncertainties involved with the ex vivo analysis as described above. This then points out to the need of developing an internal reference system in the OECT that will enable us to treat the data quantitively as well, something that will be the focus of a future work.
Xylem sap transport of sugars has been reported for several tree species, including birch, willow, sugar maple, and Populus (Heizmann et al., 2001; Mayrhofer et al., 2004; Furukawa et al., 2011; Mahboubi and Niittylä, 2018). Changes in xylem sap sugar content are often associated with the spring time initiation of growth and flowering in temperate region species, illustrating the importance of the xylem sap sugar transport pathway for the seasonal growth of trees (Furukawa et al., 2011). Our experiments were conducted under controlled greenhouse conditions in fast-growing young aspen trees, which are not mobilizing long-term stores of carbon. The diurnal fluctuation in xylem sap sucrose levels that we observe with the OECT sensors is therefore likely to be associated with diurnal physiological and metabolic processes such as diurnal growth rate variation and starch degradation at night.
Diurnal xylem processes in trees have been observed for developing wood cell wall biosynthesis in young hybrid aspen trees (Mahboubi et al., 2015), and turgor pressure-driven diurnal changes in the stem diameter in Cryptomeria japonica (Hosoo et al., 2003). In the latter case, the stem diameter increased during the night and decreased during the day likely due to diurnal changes in water transpiration. Night time transpiration occurs in trees albeit at a lower level compared to day time (Daley and Phillips, 2006). However, since the OECT measurements showed that xylem sap glucose levels did not change, the sucrose change may be related to sucrose transport and/or storage rather than to sucrose cleavage, or a reduction in the xylem sap transport rate. We hypothesize that the diurnal changes in the xylem sap sucrose may be relevant for carbon allocation and as a diurnal cue at whole tree level. This example illustrates that the OECT sensor technology can provide new insights to carbon allocation and sugar metabolism in trees that cannot be obtained using classic xylem sap sampling methods.
Conclusions
In this work, we developed implantable OECT-based enzymatic biosensors that can operate in the complex in vivo environment for 48hr and in real-time monitor sugar variations in the vascular tissue of trees. We extended the range of analytes that can be detected enzymatically with an OECT by developing a biofunctionalization strategy that allows multiple enzymes to be immobilized in the same device and catalyze a chain reaction. Furthermore, we designed a cheap Arduino-based source-measure unit that allows the operation of the device in the growth environment of plants and showcase its potential for application in field conditions. One of the main limitations of our technology is that we can make only qualitative observations as quantification is hindered by the unknown initial concertation of the analyte in the in vivo environment. Nevertheless, relative changes in biology are very important, and we report for the first time that sucrose in mature xylem shows a diurnal dependence indicating that sucrose transport in the xylem is correlated to metabolic or physiological processes. The principle of OECT technology can be applied to assess many metabolites, as well as, the effect of developmental and environmental cues, or abiotic and biotic stresses on the metabolites levels. The sensors are an example of non-invasive dynamic monitoring technology, which will contribute to a better understanding of tree growth dynamics. The technology may also find applications in related areas such as the study of xylem sap feeding insect behavior. Since the operation of the sensors does not depend on genetic modification, they can be readily applied in agriculture and forestry without ethical or societal restrictions. Although OECT technology development is highly driven by biomedical applications, our work demonstrates the usefulness and applicability of bioelectronic technologies in plants for elucidating fundamental questions that currently cannot be answered with the conventional methods and tools.
Limitations of the study
In this work, we reported OECT enzymatic biosensors for in vivo, real-time monitoring of sucrose and glucose variations in the xylem vascular tissue of hybrid aspen trees. Currently, our technology can be used only for qualitative observations as quantification is hindered by the unknown initial concertation of the analyte in the in vivo environment. Although relative changes in biology are important, quantifying the concertation of sugars will provide additional insight on the sugars transport. Furthermore, the wounding assay revealed that the plant is creating cork tissue after five days of implantation at the insertion point of the sensor which could result in isolating the sensors from the xylem and therefore limiting the duration of in vivo monitoring. Future work will focus on engineering further the sensor design to first enable quantitative in vivo sensing and secondly to minimizing cork tissue formation for extending the duration of real-time monitoring to several days.
Resource availability
Lead contact
Further information and requests for resources and materials should be directed to and will be fulfilled by the lead contact, Dr. Eleni Stavrinidou (eleni.stavrinidou@liu.se)
Materials availability
This study did not generate new unique reagents.
Data and code availability
Source data for the figures published in this the paper are available per request.
Methods
All methods can be found in the accompanying Transparent Methods supplemental file.
Acknowledgments
The authors wish to thank Benoit Piro from Paris-Diderot University, Xenofon Strakosas and Per Jansson from Linköping University for fruitful discussions for the sensors design. Special thanks to Thor Balkhed, Linköping University for the photographs of Figures 3A and 3B. Funding was provided by the European Union's Horizon 2020 research and innovation program under grant agreement No 800926 (FET-OPEN-HyPhOE), the Swedish Foundation for Strategic Research (SSF), the Knut and Alice Wallenberg Foundation, the Wallenberg Wood Science Center, Vetenskapsrådet (VR), and the Swedish Government Strategic Research Area in Materials Science on Functional Materials at Linköping University (Faculty Grant SFO-Mat-LiU No. 2009-00971). This work was also supported by the Umea Plant Science Center, Berzelii Centre for Forest Biotechnology funded by VINNOVA. Additional funding was provided by a Marie Sklodowska Curie Individual Fellowship (MSCA-IFEF-ST, Trans-Plant, 702641) to ES and by an ERC-Advanced Grant to MB. Figures were created with BioRender.com.
Author contributions
E.S. and T.N. conceived and designed the project, C.D. fabricated and characterized the OECT-sensors and performed all in vivo experiments with the help of T.A. and J.L., T.A. performed the wounding assay and the ex vivo xylem sap collection and analysis, C.D. and T.A. analyzed data; E.G. developed the portable measurement platform; C.D., T.A., E.G., T.N. and E.S. wrote the initial draft and final manuscript with input from all the authors; E.S. and T.N. supervised the project.
Declaration of interests
The authors declare no competing interests.
Published: January 22, 2021
Footnotes
Supplemental Information can be found online at https://doi.org/10.1016/j.isci.2020.101966.
Contributor Information
Totte Niittylä, Email: totte.niittyla@slu.se.
Eleni Stavrinidou, Email: eleni.stavrinidou@liu.se.
Supplemental information
References
- Alexou M., Peuke A.D. Chapter 13 methods for xylem sap collection. Plant Mineral. Nutrients. 2013;953:195–207. doi: 10.1007/978-1-62703-152-3_13. [DOI] [PubMed] [Google Scholar]
- Berggren M., Richter-Dahlfors A. Organic bioelectronics. Adv. Mater. 2007;19:3201–3213. [Google Scholar]
- Bernacka-Wojcik I., Huerta M., Tybrandt K., Karady M., Mulla M.Y., Poxson D.J., Gabrielsson E.O., Ljung K., Simon D.T., Berggren M., Stavrinidou E. Implantable organic electronic ion pump enables ABA hormone delivery for control of stomata in an intact tobacco plant. Small. 2019;15:1–9. doi: 10.1002/smll.201902189. [DOI] [PubMed] [Google Scholar]
- Bernards D.A., Macaya D.J., Nikolou M., DeFranco J.A., Takamatsu S., Malliaras G.G. Enzymatic sensing with organic electrochemical transistors. J. Mater. Chem. 2008;18:116–120. [Google Scholar]
- Berto M., Diacci C., Theuer L., Di Lauro M., Simon D.T., Berggren M., Biscarini F., Beni V., Bortolotti C.A. Vol. 3. IOP Publishing; 2018. Label free urea biosensor based on organic electrochemical transistors; p. 24001. (Flexible and Printed Electronics). [Google Scholar]
- Chaudhuri B., Hörmann F., Frommer W.B. Dynamic imaging of glucose flux impedance using FRET sensors in wild-type Arabidopsis plants. J. Exp. Bot. 2011;62:2411–2417. doi: 10.1093/jxb/erq444. [DOI] [PubMed] [Google Scholar]
- Coppedè N., Janni M., Bettelli M., Maida C.L., Gentile F., Villani M., Ruotolo R., Iannotta S., Marmiroli N., Marmiroli M., Zappettini A. An in vivo biosensing, biomimetic electrochemical transistor with applications in plant science and precision farming. Sci. Rep. 2017;7:1–9. doi: 10.1038/s41598-017-16217-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Curto V.F., Marchiori B., Hama A., Pappa A.-M., Ferro M.P., Braendlein M., Rivnay J., Fiocchi M., Malliaras G.G., Ramuz M., Owens R.M. Organic transistor platform with integrated microfluidics for in-line multi-parametric in vitro cell monitoring. Microsyst. Nanoeng. 2017;3:1–12. doi: 10.1038/micronano.2017.28. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Daley M.J., Phillips N.G. Interspecific variation in nighttime transpiration and stomatal conductance in a mixed New England deciduous forest. Tree Physiol. 2006;26:411–419. doi: 10.1093/treephys/26.4.411. [DOI] [PubMed] [Google Scholar]
- Demuru, S. et al. (2019) ‘Flexible Organic Electrochemical Transistor with Functionalized Inkjet-Printed Gold Gate for Bacteria Sensing’, 2019 20th International Conference on Solid-State Sensors, Actuators and Microsystems and Eurosensors XXXIII, TRANSDUCERS 2019 and EUROSENSORS XXXIII. IEEE, 1(June), pp. 2519–2522.not available in PubMed,Crossref
- Deuschle K., Chaudhuri B., Okumoto S., Lager I., Lalonde S., Frommer W.B. Rapid metabolism of glucose detected with FRET glucose nanosensors in epidermal cells and intact roots of Arabidopsis RNA-silencing mutants. Plant Cell. 2006;18:2314–2325. doi: 10.1105/tpc.106.044073. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Di Lauro M., la Gatta S., Bortolotti C.A., Beni V., Parkula V., Drakopoulou S., Giordani M., Berto M., Milano F., Cramer T. A bacterial photosynthetic enzymatic unit modulating organic transistors with light. Adv. Electron. Mater. 2020;6:1–5. [Google Scholar]
- Diacci C., Lee J.W., Janson P., Dufil G., Mehes G., Berggren M., Simon D.T., Stavrinidou E. Real-time monitoring of glucose export from isolated chloroplasts using an organic electrochemical transistor. Adv. Mater. Tech. 2020;5:1–6. 1900262. [Google Scholar]
- Farrar J., Pollock C., Gallagher J. Sucrose and the integration of metabolism in vascular plants. Plant Sci. 2000;154:1–11. doi: 10.1016/s0168-9452(99)00260-5. [DOI] [PubMed] [Google Scholar]
- Furukawa J., Abe Y., Mizuno H., Matsuki K., Sagawa K., Kojima M., Sakakibara H., Iwai H., Satoh S. Seasonal fluctuation of organic and inorganic components in xylem sap of Populus nigra. Plant Root. 2011;5:56–62. [Google Scholar]
- Graf A., Schlereth A., Stitt M., Smith A.M. Circadian control of carbohydrate availability for growth in Arabidopsis plants at night. Proc. Natl. Acad. Sci. U S A. 2010;107:9458–9463. doi: 10.1073/pnas.0914299107. [DOI] [PMC free article] [PubMed] [Google Scholar]
- He R.-X., Zhang M., Tan F., Leung P.H.M., Zhao X.-Z., Chan H.L.W., Yang M., Yan F. Detection of bacteria with organic electrochemical transistors. J. Mater. Chem. 2012;22:22072–22076. [Google Scholar]
- Heizmann U., Kreuzwieser J., Schnitzler J.-P., Brüggemann N., Rennenberg H. Assimilate transport in the xylem sap of pedunculate oak (Quercus robur) saplings. Plant Biol. 2001;3:132–138. [Google Scholar]
- Hosoo Y., Yoshida M., Imai T., Okuyama T. Diurnal differences in the innermost surface of the S2 layer in differentiating tracheids of Cryptomeria japonica corresponding to a light-dark cycle. Holzforschung. 2003;57:567–573. [Google Scholar]
- Janni M., Coppede N., Bettelli M., Briglia N., Petrozza A., Summerer S., Vurro F., Danzi D., Cellini F., Marmiroli N. In vivo phenotyping for the early detection of drought stress in tomato. Plant Phenomics. 2019;2019:1–10. doi: 10.34133/2019/6168209. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Jorge T.F., Mata A.T., António C. Mass spectrometry as a quantitative tool in plant metabolomics. Philos. Trans. A. Math. Phys. Eng. Sci. 2016;374:20150370. doi: 10.1098/rsta.2015.0370. Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kergoat L., Piro B., Simon D.T., Pham M.C., Noël V., Berggren M. Detection of glutamate and acetylcholine with organic electrochemical transistors based on conducting polymer/platinum nanoparticle composites. Adv. Mater. Weinheim. 2014;26:5658–5664. doi: 10.1002/adma.201401608. [DOI] [PubMed] [Google Scholar]
- Khodagholy D., Rivnay J., Sessolo M., Gurfinkel M., Leleux P., Jimison L.H., Stavrinidou E., Herve T., Sanaur S., Owens R.M., Malliaras G.G. High transconductance organic electrochemical transistors. Nat. Commun. 2013;4:1–6. doi: 10.1038/ncomms3133. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kim J.J., Allison L.K., Andrew T.L. Vapor-printed polymer electrodes for long-term, on-demand health monitoring. Sci. Adv. 2019;5:eaaw0463. doi: 10.1126/sciadv.aaw0463. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Liao C., Zhang M., Niu L., Zheng Z., Yan F. Organic electrochemical transistors with graphene-modified gate electrodes for highly sensitive and selective dopamine sensors. J. Mater. Chem. B. 2014;2:191–200. doi: 10.1039/c3tb21079k. [DOI] [PubMed] [Google Scholar]
- Liao C., Mak C., Zhang M., Chan H.L., Yan F. Flexible organic electrochemical transistors for highly selective enzyme biosensors and used for saliva testing. Adv. Mater. Weinheim. 2015;27:676–681. doi: 10.1002/adma.201404378. [DOI] [PubMed] [Google Scholar]
- Mahboubi A., Linden P., Hedenström M., Moritz T., Niittylä T. 13C tracking after 13CO2 supply revealed diurnal patterns of wood formation in aspen. Plant Physiol. 2015;168:478–489. doi: 10.1104/pp.15.00292. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Mahboubi A., Niittylä T. Sucrose transport and carbon fluxes during wood formation. Physiol. Plant. 2018;164:67–81. doi: 10.1111/ppl.12729. [DOI] [PubMed] [Google Scholar]
- Mayrhofer S., Heizmann U., Magel E., Eiblmeier M., Müller A., Rennenberg H., Hampp R., Schnitzler J.P., Kreuzwieser J. Carbon balance in leaves of young poplar trees. Plant Biol. (Stuttg) 2004;6:730–739. doi: 10.1055/s-2004-821268. [DOI] [PubMed] [Google Scholar]
- Nilsson D., Chen M., Kugler T., Remonen T., Armgarth M., Berggren M. Bi-stable and dynamic current modulation in electrochemical organic transistors. Adv. Mater. 2002;14:51–54. [Google Scholar]
- Pappa A.M., Curto V.F., Braendlein M., Strakosas X., Donahue M.J., Fiocchi M., Malliaras G.G., Owens R.M. Organic transistor arrays integrated with finger-powered microfluidics for multianalyte saliva testing. Adv. Healthc. Mater. 2016;5:2295–2302. doi: 10.1002/adhm.201600494. [DOI] [PubMed] [Google Scholar]
- Pappa A.M., Ohayon D., Giovannitti A., Maria I.P., Savva A., Uguz I., Rivnay J., McCulloch I., Owens R.M., Inal S. Direct metabolite detection with an n-type accumulation mode organic electrochemical transistor. Sci. Adv. 2018;4:1–8. doi: 10.1126/sciadv.aat0911. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Parlak O., Keene S.T., Marais A., Curto V.F., Salleo A. Molecularly selective nanoporous membrane-based wearable organic electrochemical device for noninvasive cortisol sensing. Sci. Adv. 2018;4:eaar2904. doi: 10.1126/sciadv.aar2904. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Paulsen B.D., Tybrandt K., Stavrinidou E., Rivnay J. Organic mixed ionic–electronic conductors. Nat. Mater. 2020;19:13–26. doi: 10.1038/s41563-019-0435-z. [DOI] [PubMed] [Google Scholar]
- Pitsalidis C., Pappa A.M., Porel M., Artim C.M., Faria G.C., Duong D.D., Alabi C.A., Daniel S., Salleo A., Owens R.M. Biomimetic electronic devices for measuring bacterial membrane disruption. Adv. Mater. 2018;30:1–8. doi: 10.1002/adma.201803130. [DOI] [PubMed] [Google Scholar]
- Poxson D.J., Karady M., Gabrielsson R., Alkattan A.Y., Gustavsson A., Doyle S.M., Robert S., Ljung K., Grebe M., Simon D.T., Berggren M. Regulating plant physiology with organic electronics. Proc. Natl. Acad. Sci. U S A. 2017;114:4597–4602. doi: 10.1073/pnas.1617758114. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Rennie E.A., Turgeon R. A comprehensive picture of phloem loading strategies. Proc. Natl. Acad. Sci. U S A. 2009;106:14162–14167. doi: 10.1073/pnas.0902279106. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Rivnay J., Inal S., Salleo A., Owens R.M., Berggren M., Malliaras G.G. Organic electrochemical transistors. Nat. Rev. Mater. 2018;3:1–14. 17086. [Google Scholar]
- Roitsch T., González M.C. Function and regulation of plant invertases: sweet sensations. Trends Plant Sci. 2004;9:606–613. doi: 10.1016/j.tplants.2004.10.009. [DOI] [PubMed] [Google Scholar]
- Sauter J.J., Ambrosius T. Changes in the partitioning of carbohydrates in the wood during bud break in betula pendula roth. J. Plant Physiol. 1986;124:31–43. [Google Scholar]
- Scheiblin G., Aliane A., Strakosas X., Curto V.F., Coppard R., Marchand G., Owens R.M., Mailley P., Malliaras G.G. Screen-printed organic electrochemical transistors for metabolite sensing. MRS Commun. 2015;5:507–511. [Google Scholar]
- Shim N.Y., Bernards D.A., Macaya D.J., Defranco J.A., Nikolou M., Owens R.M., Malliaras G.G. All-plastic electrochemical transistor for glucose sensing using a ferrocene mediator. Sensors (Basel) 2009;9:9896–9902. doi: 10.3390/s91209896. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Stavrinidou E., Gabrielsson R., Gomez E., Crispin X., Nilsson O., Simon D.T., Berggren M. Electronic plants. Sci. Adv. 2015;1:e1501136. doi: 10.1126/sciadv.1501136. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Stavrinidou E., Gabrielsson R., Nilsson K.P., Singh S.K., Franco-Gonzalez J.F., Volkov A.V., Jonsson M.P., Grimoldi A., Elgland M., Zozoulenko I.V. In vivo polymerization and manufacturing of wires and supercapacitors in plants. Proc. Natl. Acad. Sci. U S A. 2017;114:2807–2812. doi: 10.1073/pnas.1616456114. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Stitt M., Lilley R.Mc., Gerhardt R., Heldt H.W. Biomembranes Part U: Cellular and Subcellular Transport: Eukaryotic (Nonepithelial) Cells. Academic Press; 1989. [32] Metabolite levels in specific cells and subcellular compartments of plant leaves; pp. 518–552. [Google Scholar]
- Strakosas X., Huerta M., Donahue M.J., Hama A., Pappa A.M., Ferro M., Ramuz M., Rivnay J., Owens R.M. Catalytically enhanced organic transistors for in vitro toxicology monitoring through hydrogel entrapment of enzymes. J. Appl. Polym. Sci. 2017;134:1–7. [Google Scholar]
- Tang H., Yan F., Lin P., Xu J., Chan H.L.W. Highly sensitive glucose biosensors based on organic electrochemical transistors using platinum gate electrodes modified with enzyme and nanomaterials. Adv. Funct. Mater. 2011;21:2264–2272. [Google Scholar]
- Vurro F., Janni M., Coppede N., Gentile F., Manfredi R., Bettelli M., Zappettini A. Development of an in vivo sensor to monitor the effects of vapour pressure deficit (VPD) changes to improve water productivity in agriculture. Sensors (Switzerland) 2019;19:4667. doi: 10.3390/s19214667. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zajdel T.J., Baruch M., Méhes G., Stavrinidou E., Berggren M., Maharbiz M.M., Simon D.T., Ajo-Franklin C.M. PEDOT:PSS-based multilayer bacterial-composite films for bioelectronics. Sci. Rep. 2018;8:1–12. doi: 10.1038/s41598-018-33521-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zeglio E., Rutz A.L., Winkler T.E., Malliaras G.G., Herland A. Conjugated polymers for assessing and controlling biological functions. Adv. Mater. 2019;31:e1806712. doi: 10.1002/adma.201806712. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
Source data for the figures published in this the paper are available per request.