Skip to main content
Scientific Reports logoLink to Scientific Reports
. 2021 Jan 12;11:699. doi: 10.1038/s41598-020-77997-w

High energy implementation of coil-target scheme for guided re-acceleration of laser-driven protons

Hamad Ahmed 1,2,, Prokopis Hadjisolomou 1,3, Kealan Naughton 1, Aaron Alejo 1, Stephanie Brauckmann 4, Giada Cantono 1,5, Simon Ferguson 1, Mirela Cerchez 4, Domenico Doria 1,6, James Green 2, Deborah Gwynne 1, Thomas Hodge 1, Deepak Kumar 3, Andrea Macchi 5,7, Rajendra Prasad 4, Oswald Willi 4, Marco Borghesi 1, Satyabrata Kar 1,
PMCID: PMC7804017  PMID: 33436708

Abstract

Developing compact ion accelerators using intense lasers is a very active area of research, motivated by a strong applicative potential in science, industry and healthcare. However, proposed applications in medical therapy, as well as in nuclear and particle physics demand a strict control of ion energy, as well as of the angular and spectral distribution of ion beam, beyond the intrinsic limitations of the several acceleration mechanisms explored so far. Here we report on the production of highly collimated (0.2 half angle divergence), high-charge (10s of pC) and quasi-monoenergetic proton beams up to 50 MeV, using a recently developed method based on helical coil targetry. In this concept, ions accelerated from a laser-irradiated foil are post-accelerated and conditioned in a helical structure positioned at the rear of the foil. The pencil beam of protons was produced by guided post-acceleration at a rate of 2 GeV/m, without sacrificing the excellent beam emittance of the laser-driven proton beams. 3D particle tracing simulations indicate the possibility of sustaining high acceleration gradients over extended helical coil lengths, thus maximising the gain from such miniature accelerating modules.

Subject terms: Laser-produced plasmas, Plasma-based accelerators

Introduction

Current interest in laser-driven ion accelerators, as a radically different, compact alternative to RF accelerators, stems from remarkable properties such as large particle flux, short pulse duration and exceptional beam emittance1. However, the large angular and spectral spread of the ion beams which are intrinsic to laser-driven acceleration mechanisms, pose significant technical challenges to their applicative use. For instance, application in cancer therapy would require the delivery of high energy protons (60–250 MeV)24 with narrow energy spread and sufficient particle flux at significant distances from the interaction targets, so that the extraneous radiation produced during the intense laser interaction can be shielded adequately. There has been recent significant progress in increasing the maximum proton energies delivered through laser-driven processes, with recent reports of the acceleration of near 100 MeV protons5,6, albeit with a broad spectral content and large angular spread, with an half cone divergence of 5-10 at the highest energies.

Control of the beam divergence and of its energy spectrum have been key research objectives over the past decade, and a number of approaches using magnetic systems, target or plasma engineering713 have been explored for this purpose. The recently developed scheme based on helical coil (HC) targets14 offers, in this context, a miniature and versatile setup that, in addition to reducing the divergence and energy spread of the beams, has been shown to post-accelerate the guided protons at a rate of the order of GV/m. In this scheme, the electromagnetic (EM) pulse generated due to transient charging of an intense-laser irradiated foil1418 is directed to travel along the helical path defined by an HC. The characteristics of the EM pulse are governed by the generation of hot electrons and their dynamics during the laser interaction and hence depend on a number of laser and target parameters17,18. While traveling along the windings of the HC, the EM pulse generates a strong electric field pattern which travels along the coil with a speed depending on the coil radius and pitch. Through a suitable choice of these parameters, it can be made to match the speed at which 10s of MeV protons travel. Deploying the coil at the rear side of the laser irradiated foil, protons within a narrow energy range are allowed to co-propagate with the travelling field pattern, enabling the synchronised proton bunch to be guided and post-accelerated simultaneously under the effect of the radial and longitudinal components of the electric field14,19.

In this article, we demonstrate the generation of highly directional beams (half-angle divergence 0.2) of protons with energies up to 50 MeV and narrow energy spread ( 10% FWHM), by employing HC targets at petawatt-class laser systems. The proton flux in the pencil beam at the spectral peak ( 45 MeV) is of the order of 1012/MeV/sr, which is orders of magnitude higher than the fluxes typically generated by the TNSA mechanism at the high energy end of the spectrum5,6,20,21. Particle tracing simulations corroborate the experimental results, showing synchronous focusing and post-acceleration of transiting protons at a rate of 2 GeV/m, about four times larger than reported in the first demonstration of the HC technique14 and well beyond the capabilities of conventional RF accelerators. The scaling for Ti:Sa systems have been discussed in the ref.14, which shows that acceleration gradients of multi-GeV/m can be achieved with ultra-short, petawatt class lasers. A current limitation of the scheme will be discussed, together with a possible scheme to overcome it towards the production of beamlets at energies of therapeutic interest.

Results

The data presented in this paper were collected from two experimental campaigns employing similar laser parameters, (see “Materials and methods” section for details). Fig. 1a shows a schematic of the HC target employed in the experiments, where the HC was placed at a few millimetres away from the interaction foil, and connected to the interaction foil by a metallic wire (the ‘delay line’). This configuration enabled precise control of the arrival time at the HC of the EM pulse relative to the arrival of the protons from the foil by either varying the length of the delay line, or the distance between the HC and the foil. Fig. 1b,c show results relating to the production of pencil beams of protons with a narrow energy bandwidth peaking at 45 MeV. As can be seen in Fig. 1b,c, the experimental data shows a highly collimated beamlet with energies up to 49 MeV, well beyond the maximum proton energies observed from reference flat foil shots taken during the campaign. The diameter of the central bright spot (containing more than 75% of the total flux) at the detector (Radiochromic film (RCF)) plane, 60 mm away from the target, is less than the internal diameter of the HC (shown by the black dashed circles in the zoomed-in views of the RCF images in Fig.1b,c). The spectral profile of the guided beam produced by the HC was reconstructed from the RCF data, as shown in Fig. 1d. Compared to the exponentially decaying spectra obtained from the reference flat foil shot, as typically expected from the TNSA mechanism, the on-axis proton spectra from the HC targets showed a pronounced, narrow spectral peak at 45 MeV with a full width at half maximum (FWHM) energy spread of less than 10% and peak prominence better than an order of magnitude. The number of protons at the spectral peak was of the order of 108/MeV (proton flux of the order of 1012/MeV/sr), which one could filter out (for instance, by using conventional accelerator optics23,24) from the rest of the spectrum to deliver narrow-band, collimated proton beams for applications.

Figure 1.

Figure 1

(a) Schematic of the setup (not to scale) used in the experiment. The HCs were made of 0.125 mm thick stainless steel wire and had pitch, internal diameter and length of 0.7±0.025mm, 0.7±0.015mm and 7.7±0.1mm respectively. The HC was placed at 1.5±0.05mm from a 10μm gold (Au) foil and connected to the foil by a delay line of length 6±0.1mm. The Radiochromic films (RCF) stack detector was placed at 60±1mm from the interaction foil. Proton beam footprints captured by different RCF layers in the stack, corresponding to different proton energies, are shown in (b-1) - (b-5). The scale shown at the top right corner of (b-3) refers to the RCF plane. Zoomed-in views of the dose profiles for the high energy pencil beams are shown in (b-4i), (b-5i), (c-i) and (c-ii), where the last two snapshots are obtained from a second shot during the campaign using very similar laser and target parameters. The white-dashed circles on the zoomed-in views corresponds to the internal diameter of the HC. (d) shows the comparison between a typical proton spectrum obtained from reference flat foil targets and three HC target shots, RCF images from two of which (labelled as HC target-1 and HC target-2, respectively) are shown in (b,c). The spectrum labelled as HC target-3 was obtained from a shot taken at similar interaction conditions, using a HC target syncing similar energy protons (30 MeV) as in case of (b,c) with an internal diameter and pitch of 0.5±0.015mm and 0.5±0.02mm respectively. The on-axis proton spectra were obtained from the RCF data, as described in refs.22,28, considering the proton dose from the area enclosed by the black-dashed circles in the zoomed-in RCF views, corresponding to 0.33 half angle divergence (10-4sr). The error bars were estimated considering the error in dose conversion22 and uncertainties in background subtraction.

The pencil beam of high energy protons results from the unique capability of chromatic guiding and post-acceleration offered by the HC targets. For a given HC radius and pitch, the strong focussing and accelerating fields move longitudinally along the HC axis with a fixed speed, which for the case shown in Fig. 1 was close to that of 30 MeV protons. At a given time the field pattern spans over a few windings of the HC as described in ref.14. While the maximum focusing field exists over the plane defined by the location the peak of the EM pulse, the accelerating field is optimum at a small distance (a few hundreds of microns depending on the HC radius and pitch) ahead of this position14. The delay line design of the HC targets, as used in the experiment, aids injecting the appropriate energy protons slightly ahead of the EM pulse peak, so that the protons clutch to the leading part of the field pattern and experience the optimum accelerating field.

Figure 2 illustrates the dynamics of transiting protons through the HC target, as reconstructed through particle tracing simulations employing the PTRACE code (see “Materials and methods” section). In Fig. 2a, the HC is seen accelerating efficiently the leading bunch of protons (28±1MeV) entering the HC, whereas the lower energy protons entering later in time, i.e. after the arrival of the EM pulse peak, are decelerated due to the reversal of the longitudinal field, which points towards the proton source in the trailing part of the field pattern. Furthermore, as shown in Fig. 2b, within the accelerated bunch, the fastest protons which are sufficiently ahead of the EM pulse peak do not experience a strong focussing field and exit the HC without significant divergence reduction. Therefore, it is protons from a narrow slice of the input spectrum which emerge with an extremely low divergence and a significant energy gain—this simultaneous effect of energy-selection, focussing and post-acceleration is a capability unique to the HC targets. As indicated in Fig. 2, the HC target used for the shots shown in Fig. 1b acted efficiently on protons of 28±1MeV, delivering a pencil beam of 45 MeV with 6 MeV FWHM bandwidth (Fig. 2c), in a good agreement with the experimental results shown in Fig. 1d.

Figure 2.

Figure 2

(a) and (b) highlight the dynamics of transiting protons through the HC obtained by particle tracing simulations, carried out using a source delivering a poly-energetic and divergent beam of protons in the setup shown in Fig 1a, with dimensions of the HC target used for the case shown in Fig. 1b. The simulation used the EM pulse profile measured in the experiment by proton probing, in a similar way as described in ref.16 and follows the propagation of protons with initial energy in the range of 25-35 MeV ( i.e. with energies close to synchronisation with the moving field for this specific target design). (a) shows the change in energy of protons while travelling along the HC axis Z (with proton source at z=0 mm and HC spanning from z = 1.5 to 9.2 mm, as per the experimental setup). (b) shows their divergence at z=20mm, i.e. 1cm after emerging from the HC. In both graphs, the vertical axis refers to final output energy of the protons while the colormap indicates their energy at the source. (c–e) show the energy spectrum, temporal and spatial spread respectively for protons in the collimated beam, having half angle divergence θ<0.4.

As shown in Fig. 1b,c, the diameter of the guided beam at 60 mm away from the target is smaller than the internal diameter (0.7 mm) of the HC, which indicates a half-angle divergence less than 0.33. In order to characterise more precisely the beam divergence, beam profiles from three HC targets of 0.7±0.015mm internal diameter and 0.35±0.015mm pitch were recorded at different distances from the targets. Fig. 3b–d show beam profiles taken at 60 mm, 100 mm, and 200 mm from the interaction foil. As can be seen in Fig. 3e, the peak dose at 100 mm from the interaction foil is still several hundreds of Gy, providing ample scope for high dose delivery to a remote irradiation site, as required by numerous applications. The beam waist (FWHM) of 0.6±0.05mm at 60 mm, expanded to 1.5±0.1mm at 200 mm, corresponds to a nominal half-angle at half-maximum divergence of 0.2. Taking the 0.7 mm diameter exit aperture of the HC as an upper estimate for the source size of the pencil beam, an upper limit for the beam’s normalised transverse emittance (βpr0Δθ, where βp is the ratio between proton velocity to speed of light in vacuum, r0 being the source radius and Δθ being the half angle divergence of the beam) can be estimated as 0.15πmm mrad, indicating that the exceptional transverse emittance of TNSA beams (orders of magnitude lower than in RF accelerators)25,26 is substantially preserved.

Figure 3.

Figure 3

(a) Experimental setup (not to scale) used for characterizing the degree of beam collimation achieved by HC targets. Irradiating identical HC targets at similar laser conditions, proton beams were diagnosed by placing the RCF stack at different distances from the interaction foil. The HC targets used in this case were made of 0.125 mm thick Stainless steel wire of internal diameter, pitch and length of 0.7±0.015mm, 0.35±0.015mm and 10±0.1mm respectively , designed to synchronise optimally with 9 MeV protons and post-accelerate them to 30 MeV. (b–d) show spatial profiles of 30 MeV proton beams captured by the RCF stack placed at 60±1mm, 100±1mm and 200±1mm respectively. (e) shows the 3D dose profile of the proton beam shown in (c).

The HC module is essentially a travelling-wave linear accelerator, where the accelerating field moves with the protons, so that the synchronised bunch of protons inside the HC experience a quasi-uniform field over an extended distance which favours the conservation of their longitudinal emittance. As can be seen in Fig. 2d,e, the collimated bunch of protons at around 45 MeV exits with an extremely low temporal and longitudinal spread (FWHM spreads of 10 ps and 0.94 mm respectively). Such ultra-short, localised bunch of ions could therefore be injected efficiently in subsequent stages of post-acceleration, for example using separate HC modules as proposed in ref.14.

Discussion

While multi-staging of HC targets offers an attractive route towards a robust,‘all-optical’ accelerator, there is significant scope for performance optimisation of a single stage. A key parameter towards increasing energy gain is the length (L) of the accelerating module, which for the data shown in Fig. 1b was 7.7 mm. The effect of L on post-acceleration was studied experimentally by deploying HCs of different lengths (2-10 mm), while keeping the same radius and pitch (see Fig 4 caption for details). As can be seen in Fig. 4a, the experimental data shows a steady increase in energy of the guided protons with the HC length up to L8mm. The particle tracing simulations indicate that a steady energy gain of 2.1±0.1MeV/mm was maintained within this range. For longer HCs however, the net energy gain saturates, as can be seen clearly from the simulations, which are in agreement with the data obtained from the 10 mm long HC.

Figure 4.

Figure 4

(a) Energy gain as a function of length of the HC target obtained from experiment (red) and simulations (Blue). The HC targets ( 0.7±0.015mm internal diameter and 0.35±0.015mm pitch) used in this case were similar to that used for the data shown in Fig. 3, except the length of HC which was varied from 2 to 10 mm. The simulations were carried out using the particle tracing code, as in Fig. 2, reconstructing the physical dimensions of the HCs used in the experiment and scanning for the HC length beyond the range studied in the experiment. The black circles show the simulated energy gain from a suitably designed varying pitch HC as calculated from the analytical model discussed in the text. (b) and (c) show dynamics of transiting protons (in a similar fashion as Fig. 2) through a constant and a variable pitched HCs, respectively. The HCs in both cases extend from z=1.5 to 16.5 mm with internal diameter 0.5 mm and initial pitch 0.5 mm. While the HC in (b) maintains a constant pitch over its full length, the pitch in (c) was varied according to Eq. (1), which gives a pitch increase of 13μm per turn. The beam divergence shown in (b,c) were taken at z=100mm and the energy spectra were plotted for a half-angle divergence <0.4.

This saturation is due to dephasing between the accelerated bunch of protons and the travelling field pattern, since an increase in proton energy by tens of MeV will lead to protons overruning the field pattern, which for the case shown in Fig. 4a occurs after 8 mm of propagation. This problem can be mitigated by varying, continuously or in steps, either the radius or the pitch (or both), of the HC to maintain the travelling field pattern in phase with the protons.

The necessary modification to the HC geometry can be estimated by a simple analytical model as described here. Protons of energy Ep(z)=γp(z)mpc2=mpc2+Tin+Gz, where mp is the proton rest mass, c is the speed of light in vacuum, Tin is the kinetic energy of the protons entering the HC and G is the energy gain per unit length inside the HC, need to remain at a fixed distance in front of the peak of the EM pulse, which requires the electric field pattern to travel with the same velocity as the protons at any given z. The velocity of the travelling field can be varied by changing either the radius or the pitch of the HC. For the purpose of this calculation we consider the pitch variation only as these are easier to implement in practice. The longitudinal velocity of the field pattern inside the HC can be expressed as vz(z)=cβEMp(z)/(2πr)2+p2(z), where r and p are the diameter and pitch of the HC respectively and βEM=vEM/c, where vEM is the velocity of the EM pulse along a straight wire, which was measured experimentally as 0.98±0.02c14,16,17. Equating the velocity of the travelling field to the proton velocity, one can find an expression for varying pitch to maintain a constant acceleration over an extended length,

p(z)=2πrγp2(z)-1(βEM2-1)γp2(z)+1 1

Figure 4a shows the predicted effectiveness of using varying pitch HCs over HCs fixed pitch HCs. While the accelerated protons start to dephase significantly after 8 mm of propagation inside the constant pitch HC, simulations shows that the energy gain can be maintained at the previous rate for an extended length of the HC by increasing the pitch according to the formula shown above. As we increase the acceleration gradient (G), either by increasing the amplitude of the EM pulse (as expected at multi-petawatt laser facilities14), and/or decreasing the radius (r) of the HC, using variable pitch HCs will be needed to maximize acceleration capabilities. As an example, Fig. 4b,c further elaborate the benefit of using a variable pitch HC over a constant pitch HC. For this comparison, HCs of 0.5 mm internal diameter were used which would provide G3.0MeV/mm with the same EM pulse produced in our experiment. While dephasing between proton bunch and electric field pattern in the constant pitch HC terminates the energy gain prematurely part way through the HC, the simulation suggests that a suitably designed variable pitch HC of 15 mm length could have produced a narrow bandwidth pencil beam of 75 MeV, i.e at an energy already adequate for treating ocular tumours or subcutaneous cancers for instance, and that could be further enhanced by deploying successive, separately driven and optimized HC stages.

Materials and methods

Experiment

Experiments were conducted at two different facilities, namely the Titan laser system at Lawrence Livermore National Laboratory (LLNL, USA) and the VULCAN Petawatt (VPW) system at Rutherford Appleton Laboratory (RAL, UK). They are both Nd:Glass based laser systems operating at central wavelength of 1.053μm. In the Titan experiment, CPA pulses of duration 600±100fs and energy 150±25J were focused on target by an f/3 off-axis parabola to a spot of 7±0.5μm FWHM delivering peak intensity (2±1)×1020W/cm2. In the second experiment, VPW delivered laser pulses of 1±0.1ps duration with energy 300±50J. The laser pulses were focused by an f/3 off-axis parabola to a spot of 5.5±0.5μm FWHM, resulting in peak intensity (3.5±1)×1020W/cm2. In both experiments, 10μm thick gold foils were used for proton generation, HCs were made of 0.125 mm stainless steel wire and the laser was incident at 20 to the target normal. The spatial and spectral distribution of the proton beams was characterised by deploying a stack of dosimetrically calibrated Radiochromic films (RCF)22. The proton spectra were reconstructed by spectral deconvolution of the dose deposited in the RCF layers27, by using an iterative algorithm similar to the procedures used in refs.22,28. Starting from the last RCF layer in the stack, the final spectrum is produced by calculating spectra between Bragg peak energies of consecutive RCF layers, while considering the energy response of the RCF layers (simulated by SRIM29) in the stack and subtracting the dose contribution in a given layer by the protons stopping deeper in the stack.

Simulations

The particle tracing simulations presented in this paper were performed using the PTRACE code30, which simulates the propagation in 3D of protons from source to detector through the region where e.m. fields are present in this case the field pattern produced by the EM pulse travelling along a HC target. The protons transit through the HC together with the co-propagating electric field associated to the travelling EM pulse. The protons are traced by computing relativistic equations of motion using a Runge-Kutta fourth-order algorithm coupled with an adaptive step size monitoring routine. The HC was modelled in PTRACE using a cylindrical co-ordinate system and the physical dimensions as used in the experiment. An EM pulse of peak linear charge density 50μC/m, 5 ps half-maximum rise and 15 ps half-maximum decay, similar to that measured experimentally in both the campaigns using the technique of self-probing (described in the ref16), was set to travel along the HC wire. In the delay line configuration, the proton source was modelled as a point source located on the axis of the HC at a given distance from the entrance plane of the HC, emitting protons towards the HC with a given energy spectrum and divergence, mimicking the proton beam produced by the reference flat foil target.

Acknowledgements

Authors acknowledge funding from EPSRC [EP/J002550/1-Career Acceleration Fellowship held by S.K., EP/L002221/1, EP/K022415/1, EP/J500094/1, and EP/I029206/1], SFB/TR18, GRK1203, EC-GA284464, and Invest Northern Ireland (POC-329). D.K., acknowledges the financial support of the Ministry of Education, Youth and Sports, via project LQ1606, as part of targeted support from the National Programme of Sustainability II (Czechia). Authors also acknowledge A. Schiavi for the use of the particle tracing code, PTRACE and Dr. Jason Wiggins for insightful suggestions. Data associated with research published in this paper is accessible at 10.17034/4f68d8a8-21b4-48bd-9a32-e31101a60197.

Author contributions

The experiment was designed and led by H.A., M.B., S.K. and supported by P.H., K.N., A.A., S.B., G.C., M.C., D.D., J.G., D.G., T.H., D.K. and R.P. The data was analysed by PH, SF, HA and SK. The manuscript was written by H.A., M.B. and S.K.; A.M. and O.W. were involved in discussions.

Competing interests

The authors declare no competing interests.

Footnotes

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Contributor Information

Hamad Ahmed, Email: hahmed02@qub.ac.uk.

Satyabrata Kar, Email: s.kar@qub.ac.uk.

References

  • 1.Macchi A, Borghesi M, Passoni M. Ion acceleration by superintense laser-plasma interaction. Rev. Mod. Physics. 2013;85:751. doi: 10.1103/RevModPhys.85.751. [DOI] [Google Scholar]
  • 2.Bulanov SV, et al. Oncological hadrontherapy with laser ion accelerators. Phys. Lett. A. 2002;299:240. doi: 10.1016/S0375-9601(02)00521-2. [DOI] [Google Scholar]
  • 3.Malka V, et al. Practicality of proton therapy using compact laser systems. Med. Phys. 2004;31:1587. doi: 10.1118/1.1747751. [DOI] [PubMed] [Google Scholar]
  • 4.Linz U, Alonso J. What will it take for laser driven proton accelerators to be applied to tumour therapy? Phys. Rev. STAB. 2007;10:094801. [Google Scholar]
  • 5.Wagner F, et al. Maximum proton energy above 85 MeV from the relativistic interaction of laser pulses with micrometer thick CH2 targets. Phys. Rev. Lett. 2016;116:205002. doi: 10.1103/PhysRevLett.116.205002. [DOI] [PubMed] [Google Scholar]
  • 6.Higginson A, et al. Near-100MeV protons via a laser-driven transparency-enhanced hybrid acceleration scheme. Nat. Commun. 2018;9:724. doi: 10.1038/s41467-018-03063-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Kar S, et al. Dynamic control of laser-produced proton beams. Phys. Rev. Lett. 2008;100:105004. doi: 10.1103/PhysRevLett.100.105004. [DOI] [PubMed] [Google Scholar]
  • 8.Bartal T, et al. Focusing of short-pulse high-intensity laser-accelerated proton beams. Nat. Phys. 2012;8:139. doi: 10.1038/nphys2153. [DOI] [Google Scholar]
  • 9.Kar S, et al. Ballistic focusing of polyenergetic protons driven by petawatt laser pulses. Phys. Rev. Lett. 2011;106:225003. doi: 10.1103/PhysRevLett.106.225003. [DOI] [PubMed] [Google Scholar]
  • 10.Patel P, et al. Isochoric heating of solid-density matter with an ultrafast proton beam. Phys. Rev. Lett. 2003;91:125004. doi: 10.1103/PhysRevLett.91.125004. [DOI] [PubMed] [Google Scholar]
  • 11.Toncian T, et al. Ultrafast laser-driven microlens to focus and energy-select mega-electron volt protons. Science. 2006;312:410. doi: 10.1126/science.1124412. [DOI] [PubMed] [Google Scholar]
  • 12.Busold S, et al. Focusing and transport of high-intensity multi-MeV proton bunches from a compact laser-driven source. Phys. Rev. Sp. Top. Acc. Beams. 2013;16:101302. doi: 10.1103/PhysRevSTAB.16.101302. [DOI] [Google Scholar]
  • 13.Schollmeier, M. et al. Controlled transport and focusing of laser-accelerated protons with miniature magnetic devices. Phys. Rev. Lett.101, 055004 (2008). [DOI] [PubMed]
  • 14.Kar S, et al. Guided post-acceleration of laser-driven ions by a miniature modular structure. Nat. Commun. 2016;7:10792. doi: 10.1038/ncomms10792. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Quinn K, et al. Laser-driven ultrafast field propagation on solid surfaces. Phys. Rev. Lett. 2009;102:194801. doi: 10.1103/PhysRevLett.102.194801. [DOI] [PubMed] [Google Scholar]
  • 16.Ahmed H, et al. Investigations of ultrafast charge dynamics in laser-irradiated targets by a self probing technique employing laser driven protons. Nucl. Instrum. Methods A. 2016;829:172. doi: 10.1016/j.nima.2016.04.078. [DOI] [Google Scholar]
  • 17.Ahmed H, et al. Efficient post-acceleration of protons in helical coil targets driven by sub-ps laser pulses. Sci. Rep. 2017;7:10891. doi: 10.1038/s41598-017-06985-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Aktan E, et al. Parametric study of a high amplitude electromagnetic pulse driven by an intense laser. Phys. Plasmas. 2019;26:070701. doi: 10.1063/1.5094871. [DOI] [Google Scholar]
  • 19.Kar S, et al. Dynamic control of laser driven proton beams by exploiting self-generated, ultrashort electromagnetic pulses. Phys. Plasma. 2016;23:055711. doi: 10.1063/1.4948725. [DOI] [Google Scholar]
  • 20.Snavely RA, et al. Intense high-energy proton beams from Petawatt-laser irradiation of solids. Phys. Rev. Lett. 2000;85:2945. doi: 10.1103/PhysRevLett.85.2945. [DOI] [PubMed] [Google Scholar]
  • 21.Gaillard SA, et al. Increased laser-accelerated proton energies via direct laser-light-pressure acceleration of electrons in microcone targets. Phys. Plasmas. 2011;18:056710. doi: 10.1063/1.3575624. [DOI] [Google Scholar]
  • 22.Kirby D, et al. Radiochromic film spectroscopy of laser accelerated proton beams using the FLUKA code and dosimetry traceable to primary standards. Laser Particle Beams. 2011;29:231. doi: 10.1017/S0263034611000206. [DOI] [Google Scholar]
  • 23.Scuderi V, et al. Development of an energy selector system for laser-driven proton beam applications. Nucl. Instrum. Methods A. 2014;740:87. doi: 10.1016/j.nima.2013.10.037. [DOI] [Google Scholar]
  • 24.Margarone D, et al. ELIMAIA: A laser-driven ion accelerator for multidisciplinary applications. Quantum. Beam. Sci. 2018;2:2. doi: 10.3390/qubs2020008. [DOI] [Google Scholar]
  • 25.Borghesi M, et al. Multi-MeV proton source investigations in ultraintense laser-foil interactions. Phys. Rev. Lett. 2004;92:055003. doi: 10.1103/PhysRevLett.92.055003. [DOI] [PubMed] [Google Scholar]
  • 26.Cowan TE, et al. Ultralow emittance, multi-MeV proton beams from a laser virtual-cathode plasma accelerator. Phys. Rev. Lett. 2004;92:204801. doi: 10.1103/PhysRevLett.92.204801. [DOI] [PubMed] [Google Scholar]
  • 27.Markey, K. Development of Laser Accelerated MeV Ion Sources. PhD thesis (Queen’s University, Belfast, 2009).
  • 28.Breschi E, et al. A new algorithm for spectral and spatial reconstruction of proton beams from dosimetric measurements. Nucl. Instrum. Methods A. 2004;522:190–195. doi: 10.1016/j.nima.2003.11.199. [DOI] [Google Scholar]
  • 29.SRIM—The Stopping and Range of Ions in Matter. https://www.srim.org.
  • 30.Schiavi, A. Study of Laser Produced Plasmas by X-ray and Proton Radiography. Ph.D. thesis (Imperial College, London, 2003).

Articles from Scientific Reports are provided here courtesy of Nature Publishing Group

RESOURCES