Image Fusion During Standard and Complex Endovascular Aortic Repair, to Fuse or Not to Fuse? A Meta-analysis and Additional Data From a Single-Center Retrospective Cohort

Sabrina A N Doelare 1,*, Stefan P M Smorenburg 1,*, Theodorus G van Schaik 1, Jan D Blankensteijn 1, Willem Wisselink 1, Johanna H Nederhoed 1, Rutger J Lely 3, Arjan W J Hoksbergen 1, Kak Khee Yeung 1,2,
PMCID: PMC7816548  PMID: 32964768

Abstract

Purpose:

To determine if image fusion will reduce contrast volume, radiation dose, and fluoroscopy and procedure times in standard and complex (fenestrated/branched) endovascular aneurysm repair (EVAR).

Materials and Methods:

A search of the PubMed, Embase, and Cochrane databases was performed in December 2019 to identify articles describing results of standard and complex EVAR procedures using image fusion compared with a control group. Study selection, data extraction, and assessment of the methodological quality of the included publications were performed by 2 reviewers working independently. Primary outcomes of the pooled analysis were contrast volume, fluoroscopy time, radiation dose, and procedure time. Eleven articles were identified comprising 1547 patients. Data on 140 patients satisfying the study inclusion criteria were added from the authors’ center. Mean differences (MDs) are presented with the 95% confidence interval (CI).

Results:

For standard EVAR, contrast volume and procedure time showed a significant reduction with an MD of −29 mL (95% CI −40.5 to −18.5, p<0.001) and −11 minutes (95% CI −21.0 to −1.8, p<0.01), respectively. For complex EVAR, significant reductions in favor of image fusion were found for contrast volume (MD −79 mL, 95% CI −105.7 to −52.4, p<0.001), fluoroscopy time (MD −14 minutes, 95% CI −24.2 to −3.5, p<0.001), and procedure time (MD −52 minutes, 95% CI −75.7 to −27.9, p<0.001).

Conclusion:

The results of this meta-analysis confirm that image fusion significantly reduces contrast volume, fluoroscopy time, and procedure time in complex EVAR but only contrast volume and procedure time for standard EVAR. Though a reduction was suggested, the radiation dose was not significantly affected by the use of fusion imaging in either standard or complex EVAR.

Keywords: contrast volume, endovascular aneurysm repair, fenestrated/branched EVAR, fluoroscopy time, fusion imaging, image fusion, meta-analysis, procedure time, radiation dose, systematic review

Introduction

In the past years, imaging capabilities in the hybrid operating room have been profoundly upgraded. Standard angiography has been complemented with 3-dimensional (3D) patient-specific roadmap functionality. Image fusion merges preoperative imaging such as computed tomography angiography (CTA) with live intraoperative fluoroscopy. The operator navigates the guidewires, catheters, and sheaths guided by a 3D roadmap to enable a more accurate and easier deployment of fenestrated and branched endovascular devices and cannulation of visceral arteries.1

Several studies showed that complex (fenestrated/branched) EVAR is associated with a significant risk of acute renal failure due to the large volumes of contrast material used. Although the etiology of this problem is likely multifactorial, contrast-enhanced examinations are still the third leading cause of hospital-acquired acute renal failure.2,3 Therefore, any effort supporting a reduction in the volume of contrast media use in complex EVAR is considered highly relevant. Additionally, the cumulative effect of exposure to radiation puts patients and physicians at risk for deterministic and stochastic radiation injuries. Several strategies such as the “as low as reasonably achievable” (ALARA) principle have been proposed to minimize the risks of intraoperative radiation. However, these approaches have proved to be insufficient to reduce all risks and are subject to hospital clinical practice.4 Hence, new imaging approaches should be used to further reduce contrast and radiation exposure. Furthermore, longer procedure times involved in complex EVAR expose the patient to longer anesthesia, resulting in a prolonged recovery.5

Superior clinical outcomes with image fusion have been described in complex EVAR.4,610 However, there is no general agreement about the need for image fusion in standard EVAR. To the best of our knowledge only 2 meta-analyses concerning image fusion in EVAR have been conducted.11,12 One pooled only the data on administered contrast volume and the other contained limited image fusion cohorts. Nonetheless, no meta-analysis has been performed that pooled the data for all procedure metrics (contrast volume, radiation dose, and fluoroscopy and procedure times) for image fusion in both standard and complex EVAR. Furthermore, newer studies are available that can elucidate the effect of image fusion during standard EVAR.

To investigate the hypothesis that image fusion will reduce relevant imaging-related parameters in complex EVAR but not in standard EVAR, a systematic review and meta-analysis was conducted comparing complex to standard EVAR in terms of the aforementioned procedure parameters. To augment the limited studies available describing image fusion in standard EVAR, a cohort of EVAR patients from our hospital was included.

Materials and Methods

Study Design

A literature review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines13 to identify clinical studies describing results after image fusion during standard and complex EVAR. The search of the PubMed, Embase, and Cochrane databases was performed by a clinical librarian in December 2019. A broad search was created with the following MeSH terms: “endovascular procedures,” “fusion,” and “imaging”; the full electronic search strategy can be found in Appendix A. Only publications in the English language were selected.

Studies involving traumatic cerebral aneurysms, pediatric patients, aortic dissections, or the use of ultrasound imaging or open surgery were excluded, as were studies without preoperative CT or magnetic resonance (MR) imaging confirmation of the abdominal aortic aneurysm. Studies with <10 patients and reviews, letters, and conference abstracts were excluded. Two reviewers (S.D. and T.v.S.) performed eligibility assessments independently. Disagreements between reviewers were resolved by consensus.

Main outcome measures were the amount of iodinated contrast administered (mL), fluoroscopy time (minutes), cumulative radiation dose expressed in dose area product (DAP, Gy·cm2) or air kerma (AK, mGy), and procedure time (minutes). The secondary outcome was clinical success, which was defined as procedure success, aneurysm shrinkage, and no postoperative mortality.

The risk of bias was assessed for each study using the Methodological Index for Non-Randomized Studies (MINORS) scoring system.14 Two reviewers (S.D. and T.v.S) independently scored the articles; disagreements were resolved by consensus or consultation with a third reviewer. The MINORS system involves 12 items with a maximum global score of 24 for comparative studies. Each item was scored from 0 to 2. The items were scored 0 if not reported, 1 when reported but inadequate, and 2 when reported and adequate.

Additional Hospital Data

To supplement image fusion data for the pooled analysis, clinical data were retrieved on 61 consecutive patients treated using standard EVAR with (n=20) or without (n=41) fusion imaging at the discretion of the surgeon between March 2017 and March 2019. Another 79 patients undergoing complex EVAR (37 fusion vs 42 no fusion) between September 2010 and March 2019 were also included. Patient baseline characteristics are stated in Table 1. Details of preoperative imaging acquisition and postprocessing, 2D-3D (standard EVAR) and 3D-3D (complex) registration, and fusion imaging are provided in Appendix B.

Table 1.

Baseline Characteristics of the Hospital Cohort.a

Standard EVAR (n=61)
Complex EVAR (n=79)
Fusion (n=20) No Fusion (n=41) pb Fusion (n=37) No Fusion (n=42) pb
Men 20 (100) 39 (95) 0.04 30 (81) 33 (79) 0.584
Age, y 72.9±6.1 73.1±7.5 0.228 73.2±6.5 72.7±6.6 0.994
BMI, kg/m2 28.8±5.3 27.72±5.0 0.449 26.6±4.4 26.4±4.8 0.779

Abbreviations: BMI, body mass index; EVAR, endovascular aneurysm repair.

a

Continuous data are presented as the means ± standard deviation; categorical data are given as the counts (percentage).

b

Levene test for equality of variances.

Statistical Analysis

Data on each outcome measure were pooled to generate standardized mean differences (MDs), which were compared using the t test for equality of means. For studies that reported only medians with interquartile range, the mean ± standard deviation was calculated using the methods proposed by Wan et al.15 In meta-analysis, the studies were compared for contrast use, fluoroscopy time, radiation dose, and procedure time using the inverse variance method in random-effects models. Heterogeneity was assessed using forest plot analysis with the I2 index.16 The meta-analysis was performed in Review Manager (version 5.3.5; The Cochrane Collaboration, Copenhagen, Denmark).

Results

Characteristics of the Included Studies

Of the 11 studies selected for analysis (Figure 1), 7 were retrospective cohort studies68,10,17,18,21 and 4 were prospective cohort studies.4,9,19,20 Preoperative CTA was performed in all studies for fusion guidance except for Stangenberg et al,21 who performed preoperative MR angiography in one of their 23 patients. A variety of fusion software packages were employed: Xtra Vision9,10 (Philips, Best, the Netherlands), Syngo X-Workplace68 (Siemens Healthineers, Erlangen, Germany), VesselNavigator17,21 (Philips), RTRS EV20 (Cydar Medical, Barrington, UK), EndoNaut19 (Therenva, Rennes, France), Innova Vision/Heart4 (GE Healthcare, Chalfont St Giles, UK), and Infinix Vc-I18 (Toshiba, Medical Systems, Tokyo, Japan). The study descriptions of the included articles are summarized in Table 2.

Figure 1.

Figure 1.

Flowchart of the search strategy. EVAR, endovascular aneurysm repair.

Table 2.

Characteristics and Outcomes of the Included Studies.

First Author, Year N Study Design Preoperative Imaging Fusion Type (Vendor) Procedure (Fusion vs No Fusion) Contrast Volume, mLa Fluoroscopy Time, mina Radiation Dose, DAP (Gy⋅cm2) or AK (mGy)a Procedure Time, mina Clinical Success, %
Ahmad, 201817 152 R CTA 2FP
2D-3D (Philips)
EVAR
(n=105 vs n=47)
50 (38–59) vs 72 (60–102),
p<0.001
6.3 (5.0–9.0) vs 9.5 (6.2–12.5), p=0.067 DAP:
234.4 (158–514) vs 321.9 (143.1–494.2), p=0.457
64.5 (59–68) vs 83 (68–89), p=0.002
Dias, 20156 226 R CTA CBCT
3D-3D (Siemens)
TEVAR
(n=10 vs n=15)
53 (50–175) vs 178 (128–282),
p=0.4
14 (9–31) vs 28 (19–39), p=0.688 DAP:
90.4 (61.9–158.5) vs 173.0 (143.7–386.3),
p=0.041
83 (56–183) vs 144 (95–144), p=0.459 80 vs 100,
p=0.150
f/bEVAR
(n=33 vs n=23)
143 (196–197) vs 298 (234–363),
p<0.001
103 (84–139) vs 127 (104–157), p=0.103 DAP:
262.9 (203.0–367.7) vs 638.9 (436.9–1002.7),
p<0.001
349 (261–438) vs 459 (391–607), p=0.007 94% vs 87%,
p=0.634
fEVAR
(n=21 vs n=36)
96 (69–144) vs 208 (162–238),
p<0.001
72 (48–131) vs 87 (58–99), p=0.581 DAP:
241.7 (140.4–432.0) vs 283.2 (192.1–499.6),
p=0.581
231 (163–332) vs 277 (193–374), p=0.319 95 vs 92,
p>0.99
EVAR
(n=22 vs n=25)
84 (49–136) vs 160 (146–204),
p<0.001
25 (18–40) vs 38 (30–45.3), p=0.185 DAP:
98.9 (83.6–164.7) vs 213.8 (124.0–290.1),
p=0.013
128 (102–151) vs 149 (119–193), p=0.459 96 vs 96,
p>0.99
IBD
(n=17 vs n=24)
132 (85–185) vs 255 (224–312),
p<0.001
57 (35–76) vs 80 (60–101), p=0.077 DAP:
188.7 (121.9–234.9) vs 468.7 (328.9–617.1),
p<0.001
191 (130–258) vs 249 (191–281), p=0.131 88 vs 88,
p>0.99
Combined (n=103 vs n=123) 103 (63–145) vs 215 (166–280),
p<0.001
66 (33–102) vs 72 (42–102),
p=0.837
DAP:
199.3 (113.4–306.2) vs 328.6 (195.6–5568.8),
p<0.001
230 (134–331) vs 235 (158–364), p=0.942 92 vs 92,
p>0.99
Dijkstra, 20117 89 R CT CBCT
3D-3D (Siemens)
fEVAR
(n=40 vs n=49)
94 (72–131) vs 136 (96–199),
p=0.001
81 (54–118) vs 90 (46–128),
p=0.932
AK:
7 (4–12) vs 7 (5–10), p=0.782
330 (273–522) vs 387 (290–477), p=0.651 85 vs 90,
p=0.975
Hertault, 20144 397 P CTA 2FP
2D-3D (GE Healthcare)
EVAR
(n=44 vs n=199)
59 (50–75) vs 80 (65–106),
p=0.34
DAP:
12.2 (8.7–19.9) vs 30.0 (20.0–43.5), p<0.01
92.5 (75–120) vs 93 (75–120), p=0.97
bEVAR
(n=20 vs n=20)
120 (100–170) vs 138 (100–160),
p<0.01
DAP:
47.4 (37.2–108.2) vs 159.0 (101.8–222.4),
p<0.01
205(169–240) vs 210 (150–260), p=0.87
fEVAR
(n=18 vs n=54)
105 (70–136) vs 138 (100–160),
p=0.03
DAP:
43.7 (24.7–57.5) vs 72.9 (52–109.2), p<0.01
150 (150–160) vs 150 (105–180), p=0.39
TEVAR
(n=14 vs n=28)
80 (50–100) vs 100 (78–140),
p=0.07
DAP:
24.7 (22.0–28.7) vs 20.0 (11.4–30.0), p=0.63
80 (60–105) vs 117 (60–138),
p=0.22
Hiraoka, 201818 143 R CTA 2FP
2D-3D (Toshiba)
EVAR (n=81 vs n=62) 76.2±27.6 vs 89.0±28.5, p=0.009 AK:
768±529 vs 880±833, p=0.333
116±27 vs 113±37,
p=0.487
TEVAR
(n=83 vs n=37)
72.6±21.1 vs 85.6±31.1, p=0.009 AK:
638±463 vs 872±623, p=0.033
86.2±23.9 vs 96.4±27,
p=0.023
Kaladji, 201819 152 P CTA 2FP
2D-3D (Therenva)
EVAR
(n=49 vs n=103)
42.3±22.0 vs 81.2±48.0 p<0.001 21.9±12.0 vs
19.5±13.0 p=0.27
DAP:
70.6±4.8 vs 67.3±74, p=0.77
114±44 vs 140.8±38,
p<0.001
Maurel, 201820 65 P CTA 2FP
2D-3D (Cydar)
EVAR
(n=44 vs n=21)
45 (36–60)
(no control group)
29.5 (22–33) vs 32 (23–38), p=0.36 AK:
82 (51–115) vs 142 (61–541), p=0.028
DAP:
12.37 (7.48–23.63) vs 21.73 (8.92–85.94), p=0.11
90 (75–100) vs 90 (75–110),
p=0.56
91 vs 90.5, no p-value
McNally, 20158 72 R CTA CBCT
3D-3D (Siemens)
fEVAR
(n=12 vs n=8)
26±8 vs 69±16,
p<0.001
41±11 vs 63±29, p=0.02 DAP:
1380±520 vs 3400±1900,
p=0.001
fEVAR
(n=19 vs n=33)
39±17 vs 90±25,
p<0.001
6±21 vs 89±36, p=0.02 DAP: 2700±1400 vs 5400±2225, p<0.001 230±50 vs 330±100,
p=0.002
Combined (n=31 vs n=41) 34±15 vs 86±25,
p<0.001
55±21 vs 84±36, p<0.001 DAP:
2200±1300 vs 5000±280,
p<0.001
76 vs 84, no p-value
Sailer, 20149 62 P Dual energy CTA CBCT
3D-3D (Philips)
f/bEVAR
(n=31 vs n=31)
159±71 vs 199±78, p=0.037 50.43± 29.58
vs 59.48± 28.00,
p=0.38
312±108 vs 378±144,
p=0.022
Stangenberg, 201521 32 R CTA, MRA CBCT 3D-3D/2FP 2D-3D (Philips) EVAR
(n=16 vs n=16)
37.4±21.3 vs 77.3±23.0, p<0.001 18.4±6.8 vs 26.8±10.0, p=0.01 AK: 1067±470.4 vs 1768±696.2, p=0.004 80.4±21.2 vs 110.0±29.1,
p=0.005
Tacher, 201310 37 R CTA CBCT
3D-3D (Philips)
f/bEVAR/
chEVAR
(2D: n=9
3D: n=14
IF: n=14)
2D vs 3D vs IF 235±145 vs 225±119 vs 65±28,
p<0.001
82±46 vs 42±22 vs 80±36, p=0.04 DAP:
1188±1067 vs 984±581 vs 656±457,
p=0.18
223±123 vs 181±53 vs
189±60,
p=0.59
89 vs 100 vs 100, p=0.24
2D vs IF 235±145 vs 65±28, p<0.001 DAP: 1188±1067 vs 656±457,
p=0.35
3D vs IF 225±119 vs 65±28, p<0.001 DAP:
984±581 vs 656±457,
p=0.06
Hospital cohort, 2019 40 R CTA 2FP
2D-3D (Philips)
EVAR
(n=20 vs n=41)
105.6±36.2 vs 111.5±51.5,
p=0.66
28.8±11.2 vs 29.0±15.9, p=0.79 DAP:
159.1±102.4 vs 139.8±186.8,
p=0.67
AK:
810.7±496.7 vs 694.0±913.8, p=0.60
145.0±44.1 vs 138.8±46.8,
p=0.62
CBCT
3D-3D
f/bEVAR
(n=37 vs n=42)
161.6±59.3
(no control group)
88.1±45.86
(no control group)
DAP:
391.5±348.4
AK:
2337.2±1744.9 (no control group)
268.6±93.1 vs 321.6±154.4, p=0.11

Abbreviations: 2D-3D, 2-/3-dimensional angiography; 2FP, 2 fluoroscopic projections; AK, air kerma; bEVAR, branched endovascular aneurysm repair; CBCT, cone-beam computed tomography; chEVAR, chimney endovascular aneurysm repair; CT, computed tomography; CTA, computed tomography angiography; DAP, dose area product; EVAR, endovascular aneurysm repair; f/bEVAR, fenestrated and/or branched EVAR; fEVAR, fenestrated EVAR; IBD, iliac branch device; IF, image fusion; P, prospective; R, retrospective; TEVAR, thoracic endovascular aortic repair.

a

Data are presented as the means ± standard deviation or median (interquartile range).

For analysis, the results of Hertault et al,4 Dias et al,6 and Tacher et al10 were subdivided into fenestrated and branched EVAR subgroups. All other complex EVARs were grouped into one cohort containing both fenestrated and branched EVAR cases.

Risk of Bias

Table 3 shows the assessment of study quality using the MINORS system.14 The global scores ranged from 10 to 17 out of 24, indicating a moderate to high degree of bias. All studies lost points for prospective data collection, unbiased assessment of the study endpoints, follow-up period appropriate to the aim of the study, loss to follow-up <5%, prospective power calculation, contemporary groups, and baseline equivalence of groups. Most studies included consecutive patients, adequate control groups, and suitable endpoints, which strengthened confidence in the conclusions.

Table 3.

MINORS Score.a

Ahmad, 201817 Dias, 20156 Dijkstra, 20117 Hertault, 20144 Hiraoka, 201818 Kaladji, 201819 Maurel, 201820 McNally, 20158 Sailer, 20149 Stangenberg, 201521 Tacher, 201310
A clearly stated aim 2 2 2 2 2 2 2 2 2 2 2
Inclusion of consecutive patients 2 2 2 2 2 2 2 2 2 2 2
Prospective collection of data 0 1 1 2 1 2 2 1 1 1 1
Endpoints appropriate to the aim of the study 1 1 1 2 2 2 2 2 2 2 2
Unbiased assessment of the study endpoint 0 0 0 0 0 0 0 0 0 0 0
Follow-up period appropriate to the aim to the study 0 2 1 0 1 0 2 1 0 0 2
Loss to follow-up <5% 0 0 0 0 1 0 2 0 0 0 0
Prospective calculation of the study size 0 0 0 0 0 0 0 0 0 0 0
An adequate control group 2 2 2 1 2 2 0 1 2 2 2
Contemporary groups 1 1 1 1 2 1 1 1 1 1 1
Baseline equivalence of groups 0 2 2 0 2 2 2 0 0 0 1
Adequate statistical analyses 2 2 2 2 2 2 2 2 2 2 2
Total 10 15 14 13 17 15 17 12 12 12 15

Abbreviation: MINORS, Methodological Index for Non-Randomized Studies.

a

MINORS criteria: 0, not reported; 1: reported but inadequate; 2, reported and adequate.14

Contrast Volume

For all endovascular procedures, the contrast volume was reduced in the image fusion group compared to the control group (11 studies).4,610,1721 The amount of contrast volume in the control group is not mentioned by Maurel et al.20 Figure 2A shows the pooled results for the contrast volume used in standard EVAR procedures. Although heterogeneous (Q=30.6, p<0.001; I2=80%), the forest plot shows an estimated pooled MD with a significant difference in contrast volume of −29 mL (95% CI −40.5 to −18.5, p<0.001) after image fusion compared with no image fusion.4,6,1719,21 The results of the hospital cohort (–6 mL, 95% CI −28.3 to 16.5, p=0.67) are comparable to Hiraoka et al,18 which had the lowest MD among the meta-analyzed studies (–13 mL, 95% CI −22.1 to −3.50, p=0.009) in standard EVAR.

Figure 2.

Figure 2.

Forest plots of contrast volume for (A) standard and (B) complex endovascular aneurysm repair (subgroups were analyzed for Dias et al6 and Hertault et al4). CI, confidence interval; IV, inverse variance; SD, standard deviation.

In complex EVAR (Figure 2B), statistical heterogeneity was significant, and the between-study variability was considered high (Q=45.5, p<0.001; I2=85%) in the 6 included studies.4,610 The estimated pooled MD (–79 mL, 95% CI −105.7 to −52.4) revealed a significant (p<0.001) reduction in contrast volume after image fusion.

Fluoroscopy Time

Overall, a statistically significant difference was found in fluoroscopy time between the image fusion group and control group for complex EVAR (5 studies)610; however, there was no significant difference in standard EVAR (5 studies).6,17,1921 In addition, Stangenberg et al21 was the only study reporting a significant fluoroscopy time reduction during standard EVAR, whereas the other 4 studies reported no difference or even an increase in fluoroscopy time as can be deduced from Table 2.

Figure 3A shows the pooled results for the fluoroscopy time in standard EVAR procedures, which was not different after image fusion compared to no image fusion (0 minutes, 95% CI −3.7 to 3.6, p=0.98). There was significant heterogeneity (Q=19.9, p=0.001; I2=75%) in the 5 included studies6,17,1921 and the hospital cohort. The MD of the hospital cohort (0 minutes, 95% CI −7.2 to 6.8, p=0.79) was comparable with the meta-analysis subtotal (0 minutes, 95 CI −4.2 to 4.2, p<0.001) during standard EVAR.

Figure 3.

Figure 3.

Forest plots of fluoroscopy time for (A) standard and (B) complex endovascular aneurysm repair (subgroups were analyzed for Dias et al6). CI, confidence interval; IV, inverse variance; SD, standard deviation.

In complex EVAR (Figure 3B) statistical heterogeneity was non-significant, and the between-study variability was considered low (Q=7.65, p=0.18; I2=35%) in the 5 included studies.610 The estimated pooled MD (–14 minutes, 95% CI −24.2 to −3.5) revealed a significant (p<0.001) reduction in fluoroscopy time after image fusion compared with no image fusion.

Radiation Dose

The radiation dose (expressed as DAP or AK) was reduced in the image fusion group compared with the control group (6 studies).4,6,10,17,19,20 The radiation dose was not described by Sailer et al.9 Figure 4A shows the pooled results for the radiation dose used in standard EVAR. The estimated pooled MD revealed a nonsignificant reduction in radiation dose (–19 Gy∙cm2, 95% CI −44.2 to 5.7, p=0.13) after image fusion compared to no image fusion. There was a significant heterogeneity (Q=15, p=0.01; I2=66%) in the 5 included studies4,6,17,19,20 and the hospital cohort. The latter had an MD (19 Gy∙cm2, 95% CI −54.5 to 93.1, p=0.67) similar to Kaladji et al19 (3 Gy∙cm2, 95% CI −16.3 to 22.9, p=0.77) for standard EVAR.

Figure 4.

Figure 4.

Forest plots of radiation dose (dose area product [DAP], Gy·cm2) for (A) standard and (B) complex endovascular aneurysm repair (subgroups were analyzed for Dias et al6 and Hertault et al4). CI, confidence interval; IV, inverse variance; SD, standard deviation.

In complex EVAR (Figure 4B), there was no significant reduction in radiation dose after image fusion compared with no image fusion (–76 Gy∙cm2, 95% CI −168.3 to 16.4, p=0.11). There was significant heterogeneity (Q=27.2, p<0.001; I2=85%) in the 3 included studies.4,6,10

Procedure Time

There was a statistically significant difference in procedure time between the image fusion group and control group (11 studies).4,610,1721 As can be seen in Table 2, a statistically significant difference in procedure time between the image fusion and no fusion groups was found in 7 studies.6,8,9,1719,21 In 2 studies, the procedure times were significantly reduced in only a subgroup (the f/bEVAR subgroup described by Dias et al6 and the TEVAR subgroup of Hiraoka et al18).

Figure 5A shows the pooled results for the procedure time used in standard EVAR procedures. The estimated pooled MD revealed a statistically significant decrease in procedure time after image fusion compared to no image fusion (–11 minutes, 95% CI −21.0 to −1.8, p=0.02). There was a significant heterogeneity (Q=26.3, p<0.001; I2=73%) in the 7 included studies4,6,1721 and the hospital cohort. The standard EVAR hospital cohort MD (+6 minutes, 95% CI −18.2 to 30.2) was comparable to Hiraoka et al18 (+3 minutes, 95% CI −7.9 to 13.9).

Figure 5.

Figure 5.

Forest plots of procedure time (minutes) for (A) standard and (B) complex endovascular aneurysm repair (subgroups were analyzed for Dias et al6 and Hertault et al4). CI, confidence interval; IV, inverse variance; SD, standard deviation.

In complex EVAR (Figure 5B), statistical heterogeneity was significant, and the between-study variability was considered moderate (Q=18.3, p=0.02; I2=56%) in the 6 included studies4,610 and the hospital cohort. The estimated pooled MD revealed a significant difference in procedure time after image fusion compared with no image fusion (–52 minutes, 95% CI −75.7 to −27.9, p<0.001). The complex EVAR hospital cohort MD (–53 minutes, 95% ‒116.3 to 10.3, p=0.11) was comparable to Hertault et al4 (–49.2 minutes, 95% ‒71.8 to −26.6, p=0.03). The stent-graft configurations consisted of 234 fenestrations and/or branches (average 3.1 per case). In total there were 46 fenestrated cases, 21 branched cases, and 6 fenestrated/branched cases. Also, there were 20 stent-graft configurations with scallops and 4 with proximal cuffs (without iliac limbs).

Discussion

Image fusion is becoming a more widely utilized imaging tool during aortic endovascular procedures. However, to date little has been published about the advantages of image fusion during standard EVAR in comparison to complex EVAR. This literature review provided evidence that image fusion reduces the amount of contrast volume and procedure time for both standard and complex EVAR procedures. The contrast volume reduction is larger for complex EVAR (–79 mL, p<0.01) than in standard EVAR (–29 mL, p<0.01), which seems plausible since visualization of the arterial ostia with iodinated contrast has been replaced by on screen navigation. The meta-analysis showed a significant decrease in fluoroscopy time for complex EVAR (–14 minutes, p=0.009), while fluoroscopy time was not reduced in standard EVAR. Most studies providing data on radiation exposure suggested a dose reduction, which was reflected in the current meta-analysis, though it did not reach statistical significance.

Regarding procedure times, the pooled results of all studies showed a larger reduction in the complex EVAR group (–52 minutes, p<0.001) compared with standard EVAR (–11 minutes, p=0.02). An explanation for this is unknown; however, from our own experience, cannulation time of visceral arteries can be shortened with the use of image fusion.

The hospital cohort showed the most comparability with the results of Hiraoka et al18 for standard EVAR, with minor differences between fusion and no fusion. For complex EVAR, a large procedure time reduction was observed, although it was not significant. This is in line with the pooled data.

Limitations of the Outcome Parameters

When comparing the procedure metrics of image fusion with the control groups, a risk of bias is introduced. First, contrast volume reduction during EVAR relies heavily on the digital subtraction angiography (DSA) protocol choice. In this review, there were protocols with varying contrast volumes and flows between 30 mL at 15 mL/s and 7 mL at 30 mL/s. Not all papers noted their DSA protocol and not all articles noted the concentration of iodine in mg/mL of the administered contrast agent. To adequately compare fusion with no fusion, the contrast protocol should not be changed after implementing image fusion. Many studies did not give data on the contrast protocol before and after implementation of image fusion.

Second, fluoroscopy time is measured from the start of the first X-ray pulse until the end of the last pulse. The difficulty with this metric is that it is operator dependent, whereas with contrast volume a protocol can be followed. During complex EVAR, fluoroscopy is needed to visualize the catheter tip and region of interest while cannulating the visceral arteries. The only hypothesized reduction in fluoroscopy time due to image fusion is when the C-arm and table are moved to a specific region of interest, when the 3D roadmap is used without fluoroscopy, and when pre-planned C-arm angles are utilized.

Third, proper radiation dose reduction needs a multifactorial approach. The largest contributors to high radiation doses in EVAR are the amount of DSA performed per procedure and a high patient body mass index. Also, C-arm X-ray settings, such as the frames per second, collimation (smaller field of view), and fluoroscopy protocol,12,2224 can be major factors in radiation dose reduction. Not all articles noted their radiation dose protocols in terms of the aforementioned parameters. Dias et al6 describes a “combined approach” in which image fusion is implemented together with radiation dose reduction strategies.

Additionally, the registration type of image fusion can be performed by matching bony landmarks (2D-3D registration) or by matching renal and aneurysmal calcifications (3D-3D registration). Dijkstra et al7 reported the exposure to radiation of 40 patients during f/bEVAR performed using 3D-3D registration; the 3D-3D registration contributed a median radiation dose of 290 mGy (interquartile range 270, 310), which is 7-fold higher compared with our institution (median 44 mGy, interquartile range 33, 55). Stangenberg et al21 preferred 3D-3D registration because of its suggested higher accuracy even though it required more radiation. In our center, 2D-3D registration is preferred for standard EVAR given the lower registration dose compared to the total procedure radiation dose. The 3D-3D registration is used mostly for complex EVAR since image fusion is more useful during cannulation of the visceral arteries. The advantage of higher accuracy without manual correction, especially in lateral views, outweighs the disadvantage of a higher registration dose, which is comparable to a single DSA. Another reason is that the total procedure radiation dose for complex EVAR is on average 2 to 3 times higher compared to standard EVAR based on the data in this meta-analysis. The higher registration dose introduced by 3D-3D registration is a relatively small increase in total procedure radiation dose during complex EVAR.12

Fourth, the definition of procedure time is subject to debate and bias. Only the article of McNally et al8 described it as time from skin incision/puncture to bandage application. Moreover, most of the included studies mentioned explicitly that all patients were operated by experienced operators to minimize the effect of the learning curve. However, especially for complex EVAR, a learning curve is still present even for experienced operators given the relatively short period of time that fenestrated/branched stent-grafts have been available. In the study of Hertault et al,4 the procedures were performed by vascular surgeons in training as well as by experienced physicians, which may explain the absent decrease in procedure time in the fEVAR group, which can be seen in Table 2.

Additionally, procedure time can be influenced by many factors, such as operator experience, but also by the complexity of the stent-graft and the procedure and other perioperative variables. These important metrics were mentioned only by McNally et al8 and included blood loss, length of stay, and renal function among others. In their study, the use of image fusion appeared to favorably impact these perioperative outcomes.

Study Limitations

The majority of studies6-8,10,17,18,21 in this analysis had a retrospective design, and the matching process to obtain the control group was not consistent in all studies, which is likely to have influenced the outcomes. The selection of patients might have resulted in a different outcome if all procedures had been subdivided based on complexity/number of fenestrations/branches. This selection bias also applies to our own hospital data since the control group was retrospective.

It is worth noting that all operators were aware of the possible outcome measures such as contrast volumes and radiation doses, which means they might have paid close attention to these outcomes and thus lowered the amount of contrast and/or radiation dose registered. Furthermore, the current analysis is limited by the influence of operator experience on the learning curve, the relatively small patient numbers, the moderate heterogeneity among the study groups, and missing data.

Moreover, reporting standards were not uniform. Radiation dose parameters were reported as cumulative AK or DAP. AK is an approximation of the total radiation dose to the patient skin, whereas DAP is the total X-ray energy leaving the X-ray tube. From the meta-analysis, the majority of studies reported DAP and so that measure was used in the pooled data analysis.

Additionally, there are some inevitable differences between the presented studies, notably in hardware. The various hybrid operating room vendors might have influenced the radiation dose since this parameter is generated by the X-ray source. Furthermore, the use of a mobile or fixed C-arm can influence the radiation dose, as described by de Ruijter et al.12 However, since most studies in the meta-analysis focused on mean differences between fusion and control groups under mostly identical circumstances, bias due to different hardware or mobile/fixed C-arms can be considered minimal.

A separate potential bias is the volume of patients treated per center and operator. Most studies in the meta-analysis did not report their annual patient numbers for standard and complex EVAR, which could influence fluoroscopy and procedure times according to operator experience.

This meta-analysis contains only a modest sample of 11 studies with individual participant data, and methodological deficiencies, such as subgroup analysis and publication bias, could not be properly explored due to a lack of data. However, these results are sufficient to show that extensive research on image fusion during complex EVAR is needed, especially in terms of clinical success, decreasing radiation exposure, and long-term outcomes of the procedure. The use of iodinated contrast is currently indispensable during these procedures, especially in complex EVAR. Alternatives should be investigated, especially for patients who suffer from nephropathy. For instance, Dias et al6 selectively injected carbon dioxide in one of the renal arteries. Taking advantage of the slower reflux of this gas into the aorta, this lowered the DSA frame rate to 2 frames per second.

Moreover, advances can be made in image fusion registration workflow. Currently with 2D-3D or 3D-3D registration, manual interaction is needed to link the preoperative imaging with fluoroscopy. This can be tedious and time-consuming due to lack of experience.12 An automated registration algorithm could exceed human capabilities by integrating a self-learning principle via machine learning.25 Another improvement would be the use of algorithms to correct for vessel displacement (mostly iliac artery) after insertion of stiff guidewires, sheaths, and stent delivery devices to ensure a one to one 3D roadmap that continuously corrects for anatomic vessel changes.2633 With algorithms like these, the user can rely more on image fusion during the procedure. The need for large contrast volumes in order to navigate might be completely eliminated, and only small volumes of nephrotoxic contrast would be needed for image fusion validation.

Conclusion

The results of this meta-analysis confirm that image fusion significantly reduces contrast volume, fluoroscopy time, and procedure time in complex EVAR but only contrast volume and procedure time for standard EVAR. Though a reduction was suggested, the radiation dose was not significantly impacted by the use of fusion imaging in either standard or complex EVAR.

Appendix A

Database-Specific Search Queries

Medline

((“Endovascular Procedures”[Mesh] OR endo-vascular[tiab]) AND (((aortic[tiab] OR “Aneurysm”[Mesh] OR aneurysm*[tiab]) AND (repair*[tiab] OR morphol*[tiab] OR anatom*[tiab])) OR evar[tiab] OR evas[tiab] OR bevar[tiab] OR chevar[tiab] OR fevar[tiab] OR pevar[tiab] OR tevar[tiab])) AND (“Imaging, Three-Dimensional”[Mesh:noexp] OR “Radiography, Interventional”[Mesh] OR “Surgery, Computer-Assisted”[Mesh] OR ((“3 d”[tiab] OR 3d[tiab] OR 3dus[tiab] OR “3 dus”[tiab] OR 3dimension*[tiab] OR ((three[tiab] OR 3[tiab]) AND dimension*[tiab])) AND fusion[tiab]) OR (image[tiab] OR images[tiab] OR imaging[tiab] AND fusion[tiab]) OR hybrid fusion[tiab])

Embase

(‘endovascular surgery’/exp OR endovascular:ab,ti,kw) AND ((aortic:ab,ti,kw OR ‘aneurysm’/exp OR aneurysm*:ab,ti,kw) AND (repair*:ab,ti,kw OR morphol*:ab,ti,kw OR anatom*:ab,ti,kw) OR evar:ab,ti,kw OR evas:ab,ti,kw OR bevar:ab,ti,kw OR chevar:ab,ti,kw OR fevar:ab,ti,kw OR pevar:ab,ti,kw OR tevar:ab,ti,kw) AND (‘three dimensional imaging’/de OR ‘interventional radiology’/exp OR ‘computer assisted surgery’/exp OR ((‘3 d’:ab,ti,kw OR 3d:ab,ti,kw OR 3dus:ab,ti,kw OR ‘3 dus’:ab,ti,kw OR 3dimension*:ab,ti,kw OR ((three:ab,ti,kw OR 3:ab,ti,kw) AND dimension*:ab,ti,kw)) AND fusion:ab,ti,kw) OR ((image:ab,ti,kw OR images:ab,ti,kw OR imaging:ab,ti,kw) AND fusion:ab,ti,kw) OR ‘hybrid fusion’:ab,ti,kw)

Cochrane

(((aortic:ab,ti,kw or aneurysm*:ab,ti,kw) and (repair*:ab,ti,kw or morphol*:ab,ti,kw or anatom*:ab,ti,kw)) or evar:ab,ti,kw or evas:ab,ti,kw or bevar:ab,ti,kw or chevar:ab,ti,kw or fevar:ab,ti,kw or pevar:ab,ti,kw or tevar:ab,ti,kw) and (endovascular:ab,ti,kw) and (“interventional radiolog*”:ab,ti,kw OR “computer assisted surg*”:ab,ti,kw OR ((“3 d”:ab,ti,kw OR 3d:ab,ti,kw OR 3dus:ab,ti,kw OR “3 dus”:ab,ti,kw OR 3dimension*:ab,ti,kw OR ((three:ab,ti,kw OR 3:ab,ti,kw) AND dimension*:ab,ti,kw)) AND fusion:ab,ti,kw) OR (image:ab,ti,kw OR images:ab,ti,kw OR imaging:ab,ti,kw AND fusion:ab,ti,kw) OR “hybrid fusion”:ab,ti,kw)

Appendix B

Details of Preoperative Imaging Acquisition and Postprocessing, Registration, and Image Fusion for the Hospital Cohort

Preoperative Imaging

Prior to all procedures, a CTA scan of each patient was acquired at 120 kV and 130 mA·s with 512×512×~1100 voxels (voxel size 1×1×0.96 mm) and 100 mL of 300-mg I/mL contrast (Xenetix 300; Guerbet, Aulnay-sous-Bois, France). In the fusion and no fusion cohorts, the iodinated contrast protocols were similar in terms of volume and flow during administration. Vessel Navigator guidance (Philips Healthcare) was utilized in the image fusion cohort. The CTA images were loaded into a vascular workstation (Philips Interventional Tools r9.0) for automated vessel segmentation. The following arteries were manually selected for complex EVAR: the aorta, celiac artery (CA), superior mesenteric artery (SMA), right and left renal artery (RRA/LRA), possible accessory renal arteries, right and left common iliac arteries (RCIA/LCIA), and right and left internal iliac arteries (RIIA/LIIA). The ostia of the CA, SMA, RRA, LRA, RIIA, and LIIA were identified and manually marked with circular navigation markers placed orthogonal to the vessel lumen and corrected in the axial, sagittal, and coronal planes. The CA and SMA were excluded in standard EVAR. When heavy calcification at the vessel ostia was present, extra attention was paid to whether the navigation marker was placed in the true lumen by scrolling through the axial CT plane. The C-arm angles were determined by viewing the aortic branch vessels at a perpendicular angle to their origin, and navigation markers were placed by moving the virtual C-arm. The selected angles were saved for immediate recall during the procedure.

Registration and Live Guidance

For standard EVAR, two 2D fluoroscopy images were acquired with an angular difference ≥30° in the right and left anterior oblique planes. The 90° right anterior oblique and the 0° anteroposterior views were typically used in the hybrid operating room with the ceiling-mounted C-arm system (Azurion Flexmove 7 C20; Philips Healthcare). After the 2 fluoroscopy acquisitions, the registration was performed on the workstation while the patient was iodinated and draped. The 2D-3D registration was performed with alignment of the vertebral column and proximal pelvic rings, with the field of view centered on L1/L2 with registration emphasis on the vertebral column.

For complex EVAR, 3D-3D registration was performed since this relies more on millimeter image fusion accuracy during cannulation of the visceral arteries. With 3D-3D registration, a cone-beam computed tomography is performed intraoperatively. The C-arm follows a 180° circular trajectory that results in a 3D scan that is registered to the preoperative CTA by matching at least 5 renal and aneurysmal calcifications. Calcifications more distal in the iliac trajectories were excluded due to possible mismatch.

For all cases, registration was performed after patient draping and before the insertion of stiff sheaths and guidewires. After this, the preoperative CTA was fused with the fluoroscopic image stream and functioned as live guidance. After the introduction of the sheath, guidewires, diagnostic catheter, and stent-graft delivery system, a DSA was performed using an automatic iodine pump (20 mL at 15 mL/s of 300-mg I/mL UltraVist; Bayer HealthCare AG, Berlin, Germany) to visualize the ostium of the renal arteries and proximal sealing zone. When necessary, a manual correction was performed by translating the image fusion overlay to match the true ostium of the renal arteries on the DSA. From this moment, the image fusion overlay was kept fixed, and no manual correction was performed except in extreme lateral projections.

To visualize the internal iliac arteries, 10 mL of diluted contrast or 5 mL of undiluted contrast was administered, depending on the operator’s choice. At the end of each procedure, the contrast volume and procedure time (incision to wound closure) was recorded, and an automated dose report was created that included the patient radiation dose (cumulative AK), DAP, and fluoroscopy time. In the complex EVAR cohort, only procedure time was recorded in the control group and data on contrast volume, fluoroscopy/procedure times, and radiation dose were unavailable.

Footnotes

Authors’ Note: This study was presented at ESCVS 2019 (9 April 2019; Groningen, the Netherlands) and Endovascology 2019 (11 October 2019; Shanghai, China).

Declaration of Conflicting Interests: The author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.

Funding: The author(s) received no financial support for the research, authorship, and/or publication of this article.

ORCID iD: Stefan P. M. Smorenburg Inline graphic https://orcid.org/0000-0002-4754-3016

References

  • 1. Schwein A, Chinnadurai P, Behler G, et al. Computed tomography angiography-fluoroscopy image fusion allows visceral vessel cannulation without angiography during fenestrated endovascular aneurysm repair. J Vasc Surg. 2018;68:2–11. [DOI] [PubMed] [Google Scholar]
  • 2. Lindholt JS. Radiocontrast induced nephropathy. Eur J Vasc Endovasc Surg. 2003;25:296–304. [DOI] [PubMed] [Google Scholar]
  • 3. Haddad F, Greenberg RK, Walker E, et al. Fenestrated endovascular grafting: the renal side of the story. J Vasc Surg. 2005;41:181–190. [DOI] [PubMed] [Google Scholar]
  • 4. Hertault A, Maurel B, Sobocinski J, et al. Impact of hybrid rooms with image fusion on radiation exposure during endovascular aortic repair. Eur J Vasc Endovasc Surg. 2014;48:382–390. [DOI] [PubMed] [Google Scholar]
  • 5. Huang IKH, Renani SA, Morgan RA. Complications and reinterventions after fenestrated and branched EVAR in patients with paravisceral and thoracoabdominal aneurysms. Cardiovasc Intervent Radiol. 2018;41:985–997. [DOI] [PubMed] [Google Scholar]
  • 6. Dias NV, Billberg H, Sonesson B, et al. The effects of combining fusion imaging, low-frequency pulsed fluoroscopy, and low-concentration contrast agent during endovascular aneurysm repair. J Vasc Surg. 2016;63:1147–1155. [DOI] [PubMed] [Google Scholar]
  • 7. Dijkstra ML, Eagleton MJ, Greenberg RK, et al. Intraoperative C-arm cone-beam computed tomography in fenestrated/branched aortic endografting. J Vasc Surg. 2011;53:583–590. [DOI] [PubMed] [Google Scholar]
  • 8. McNally MM, Scali ST, Feezor RJ, et al. Three-dimensional fusion computed tomography decreases radiation exposure, procedure time, and contrast use during fenestrated endovascular aortic repair. J Vasc Surg. 2015;61:309–316. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9. Sailer AM, de Haan MW, Peppelenbosch AG, et al. CTA with fluoroscopy image fusion guidance in endovascular complex aortic aneurysm repair. Eur J Vasc Endovasc Surg. 2014;47:349–356. [DOI] [PubMed] [Google Scholar]
  • 10. Tacher V, Lin M, Desgranges P, et al. Image guidance for endovascular repair of complex aortic aneurysms: comparison of two-dimensional and three-dimensional angiography and image fusion. J Vasc Interv Radiol. 2013;24:1698–1706. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11. Goudeketting SR, Heinen SGH, Ünlü Ç, et al. Pros and cons of 3D image fusion in endovascular aortic repair: a systematic review and meta-analysis. J Endovasc Ther. 2017;24:595–603. [DOI] [PubMed] [Google Scholar]
  • 12. de Ruiter QMB, Reitsma JB, Moll FL, et al. Meta-analysis of cumulative radiation duration and dose during EVAR using mobile, fixed, or fixed/3D fusion C-arms. J Endovasc Ther. 2016;23:944–956. [DOI] [PubMed] [Google Scholar]
  • 13. Liberati A, Altman DG, Tetzlaff J, et al. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. PLoS Med. 2009;6:e1000100. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14. Slim K, Nini E, Forestier D, et al. Methodological index for non-randomized studies (MINORS): development and validation of a new instrument. ANZ J Surg. 2003;73:712–716. [DOI] [PubMed] [Google Scholar]
  • 15. Wan X, Wang W, Liu J, et al. Estimating the sample mean and standard deviation from the sample size, median, range and/or interquartile range. BMC Med Res Methodol. 2014;14:135. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16. Egger M, Smith GD. Bias in location and selection of studies. BMJ. 1998;316:61–66. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17. Ahmad W, Obeidi Y, Majd P, et al. The 2D-3D registration method in image fusion is accurate and helps to reduce the used contrast medium, radiation, and procedural time in standard EVAR Procedures. Ann Vasc Surg. 2018;51:177–186. [DOI] [PubMed] [Google Scholar]
  • 18. Hiraoka A, Shiraya S, Chikazawa G, et al. Feasibility of three-dimensional fusion imaging with multimodality roadmap system during endovascular aortic repair. J Vasc Surg. 2018;68:1175–1182. [DOI] [PubMed] [Google Scholar]
  • 19. Kaladji A, Villena A, Pascot R, et al. Fusion imaging for EVAR with mobile C-arm. Ann Vasc Surg. 2018;55:166–174. [DOI] [PubMed] [Google Scholar]
  • 20. Maurel B, Martin-Gonzalez T, Chong D, et al. A prospective observational trial of fusion imaging in infrarenal aneurysms. J Vasc Surg. 2018;68:1706–1713.e1. [DOI] [PubMed] [Google Scholar]
  • 21. Stangenberg L, Shuja F, Carelsen B, et al. A novel tool for three-dimensional roadmapping reduces radiation exposure and contrast agent dose in complex endovascular interventions. J Vasc Surg. 2015;62:448–455. [DOI] [PubMed] [Google Scholar]
  • 22. de Ruiter QM, Gijsberts CM, Hazenberg CE, et al. Radiation awareness for endovascular abdominal aortic aneurysm repair in the hybrid operating room. An instant patient risk chart for daily practice. J Endovasc Ther. 2017;24:425–434. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23. de Ruiter QMB, Jansen MM, Moll FL, et al. Procedure and step-based analysis of the occupational radiation dose during endovascular aneurysm repair in the hybrid operating room. J Vasc Surg. 2018;67:1881–1890. [DOI] [PubMed] [Google Scholar]
  • 24. Johnson P, Lee C, Johnson K, et al. The influence of patient size on dose conversion coefficients: a hybrid phantom study for adult cardiac catheterization. Phys Med Biol. 2009;54:3613–3629. [DOI] [PubMed] [Google Scholar]
  • 25. Varnavas A, Carrell T, Penney G. Fully automated 2D-3D registration and verification. Med Image Anal. 2015;26:108–119. [DOI] [PubMed] [Google Scholar]
  • 26. Koutouzi G, Nasihatkton B, Danielak-Nowak M, et al. Performance of a feature-based algorithm for 3D-3D registration of CT angiography to cone-beam CT for endovascular repair of complex abdominal aortic aneurysms. BMC Med Imaging. 2018;18:42. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27. Maurel B, Hertault A, Gonzalez TM, et al. Evaluation of visceral artery displacement by endograft delivery system insertion. J Endovasc Ther. 2014;21:339–347. [DOI] [PubMed] [Google Scholar]
  • 28. Gindre J, Bel-Brunon A, Rochette M, et al. Patient-specific finite-element simulation of the insertion of guidewire during an EVAR procedure: guidewire position prediction validation on 28 cases. IEEE Trans Biomed Eng. 2017;64:1057–1066. [DOI] [PubMed] [Google Scholar]
  • 29. Kaladji A, Dumenil A, Castro M, et al. Prediction of deformations during endovascular aortic aneurysm repair using finite element simulation. Comput Med Imaging Graph. 2013;37:142–149. [DOI] [PubMed] [Google Scholar]
  • 30. Matl S, Brosig R, Baust M, et al. Vascular image registration techniques: a living review. Med Image Anal. 2017;35:1–17. [DOI] [PubMed] [Google Scholar]
  • 31. Dumenil A, Kaladji A, Castro M, et al. A versatile intensity-based 3D/2D rigid registration compatible with mobile C-arm for endovascular treatment of abdominal aortic aneurysm. Int J Comput Assist Radiol Surg. 2016;11:1713–1729. [DOI] [PubMed] [Google Scholar]
  • 32. Lessard S, Kauffmann C, Pfister M, et al. Automatic detection of selective arterial devices for advanced visualization during abdominal aortic aneurysm endovascular repair. Med Eng Phys. 2015;37:979–986. [DOI] [PubMed] [Google Scholar]
  • 33. Kauffmann C, Douane F, Therasse E, et al. Source of errors and accuracy of a two-dimensional/three-dimensional fusion road map for endovascular aneurysm repair of abdominal aortic aneurysm. J Vasc Interv Radiol. 2015;26:544–551. [DOI] [PubMed] [Google Scholar]