Abstract
Not applicable.
Keywords: Venous graft, Graft patency, Preservation solutions
We appreciate the interest and comments from Dr. Caliskan and colleagues [1] about our recently published article [2]. We fully agree that many confounding factors of our experimental study may alter potential beneficial effects of storage solutions reason that the results must be interpreted with caution. The main criticism formulated by Dr. Caliskan concerns the composition of our referent solution, GALA (Glutathione, L-ascorbic acid, L-arginine and glucose; pH= 7.4). From June 2005, the department of cardiac surgery of the University Hospital of Angers uses the GALA solution in clinical practice. Historically, collaboration has been established with the cardiac surgery and perfusionnist team of Veterans Administration Medical Center of West Roxbury (Harvard Medical School) since 1999. In 2003, Thatte H. et al. showed that duration of storage time in GALA solution (from 1 h to 24 h) did not alter smooth muscle or endothelial cell function [3]. These results constituted a major turning point in our practices for the conservation of venous grafts. The clinical data recently published [4, 5] with the commercially available DuraGraft (Somahlution Inc., Jupiter, Fla) which is formulated based on the GALA solution comforted us in our practice. We have developed our own GALA solution from the formula proposed by the publication of Thatte H [3]. in accordance with European legislation about the injectable solutions. The department of Hospital Pharmacy elaborates the GALA solution with quality controls step by step in order to obtain the most neutral pH possible. We recognize that there is probably a confusion bias in the composition proposed in our article. In fact, each component is mentioned with a unit formula (“the devil is in the details”). Concept solution with these unit formulas must lead to an acid composition. For 1 liter, our solution is initially composed with the following components: 0.67 ml magnesium sulfate (15% amp. 10 ml), 59.5 mg potassium hydrogenophosphate, 1 ml magnesium chloride (10% amp.10 ml), 1.4 ml calcium chloride (10% amp. 10 ml), 1.55 ml L-ascorbic acid (1 g/5 ml), 2.67 ml potassium chloride (15% amp. 10 ml), 10 ml heparin (25,000 UI/5 ml), 20 ml D-glucose (5% (50 ml)), 25 ml sodium bicarbonate (1.4% amp. 10 ml), 40 ml sodium chloride (20% amp. 20 ml), 90 mg reduced glutathione, 150 mg L-arginine, sterile water (sufficient quantity for 1 l). The pH is between 7 and 7.8, buffering is performed in order to obtain a pH closest to 7.4 with a control on agar. Then, the packaging is presented in the form of sterile 30 ml polyethylene bottles. Only the sodium phosphate proposed by Thatte is not found in our solution because of European legislation on the pharmacopoeia of injectable solutions. It is noteworthy to mention that amounts of the GALA main components, as the rationale for efficacy of this solution, are exactly similar between the US and Europe formulations. The results of patent venous graft must be interpreted with caution due to the small sample size. Concerning the occluded grafts in particular in the GALA group, we observed an important intimal hyperplasia with intraluminal thrombus. Similar results with or without venous graft treatment were observed in arteriovenous fistula in murine model at 28 days [6] and at 6 weeks important smooth muscle cells and collagen deposits and macrophage infiltration [7].
In summary, we agree with Caliskan that our experimental study has several limitations and the results have to be taken with caution if we extrapolated to clinical practice. However, the composition of GALA solution elaborated for this experimental study is exactly the same for conservation of venous graft in coronary bypass grafting. Venous graft failure involves multiple factors and long-term follow-up in larger randomized studies is needed to evaluate the effect of storage solutions on clinical outcomes.
Acknowledgements
Not applicable.
Authors’ contributions
OF and CB drafted the manuscript. All authors revised the author’s reply and approved the final version.
Funding
Not applicable.
Availability of data and materials
Not applicable.
Ethics approval and consent to participate
Not applicable.
Consent for publication
Obtained from the participants.
Competing interests
The authors declare they have no competing interests.
Footnotes
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Caliskan E, Pachuk CJ, Perrault LP, Emmert MY. Preservation solutions to improve graft patency: The devil is in the detail. J Cardiothorac Surg. 2020;15(1):228. doi: 10.1186/s13019-020-01267-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Fouquet O, Blossier JD, Dang Van S, Robert P, Barbelivien A, Pinaud F, et al. Do storage solutions protect endothelial function of arterialized vein graft in an experimental rat model? J Cardiothorac Surg. 2020;15(1):34. doi: 10.1186/s13019-020-1077-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Thatte HS, Biswas KS, Najjar SF, Birjiniuk V, Crittenden MD, Michel T, et al. Multi-photon microscopic evaluation of saphenous vein endothelium and its preservation with a new solution, GALA. Ann Thorac Surg. 2003;75(4):1145–1152. doi: 10.1016/S0003-4975(02)04705-7. [DOI] [PubMed] [Google Scholar]
- 4.Caliskan E, Sandner S, Misfeld M, Aramendi J, Salzberg SP, Choi YH, et al. A novel endothelial damage inhibitor for the treatment of vascular conduits in coronary artery bypass grafting: protocol and rationale for the European, multicenter, prospective, observational DuraGraft registry. J Cardiothorac Surg. 2019;14(1):174. doi: 10.1186/s13019-019-1010-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Perrault LP, Carrier M, Voisine P, Olsen PS, Noiseux N, Jeanmart H, et al. Sequential multidetector computed tomography assessments after venous graft treatment solution in coronary artery bypass grafting. J Thoracic Cardiovasc Surg. 2019;S0022–5223(19):32503–32506. doi: 10.1016/j.jtcvs.2019.10.115. [DOI] [PubMed] [Google Scholar]
- 6.Wong CY, de Vries MR, Wang Y, Van der Vorst JR, Vahrmeijer AL, Zonneveld AJ, et al. Vascular remodeling and intimal hyperplasia in a novel murine model of arteriovenous fistula failure. J Vasc Surg. 2014;59(1):192–201. doi: 10.1016/j.jvs.2013.02.242. [DOI] [PubMed] [Google Scholar]
- 7.Sun Q, Kawamura T, Masutani K, Peng X, Sun Q, Stolz DB, et al. Oral intake of hydrogen-rich water inhibits intimal hyperplasia in arterialized vein grafts in rats. Cardiovasc Res. 2012;94:144–153. doi: 10.1093/cvr/cvs024. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
Not applicable.
